xs110a wireless communication module
TRANSCRIPT
CONTENTS
Toc-1
1. Introduction .............................................................................................1-11.1 Safe Use of This Product ......................................................................................1-41.2 Radio Waves .........................................................................................................1-41.3 Warranty ................................................................................................................1-5
2. Notes on Handling ...................................................................................2-12.1 ChecktheModelandSpecifications ....................................................................2-12.2 Transport ..............................................................................................................2-12.3 Storage .................................................................................................................2-12.4 Selecting the Installation Location ........................................................................2-22.5 Restrictions on Use of Radio Transceivers ..........................................................2-32.6 Explosion Protected Instrument ............................................................................2-3
3. Component Names .................................................................................3-14. Installation ................................................................................................4-15. Operation .................................................................................................5-16. Maintenance .............................................................................................6-1
6.1 Replacing the Battery............................................................................................6-16.2 Handling the Battery .............................................................................................6-4
7. GeneralSpecifications ...........................................................................7-17.1 STANDARD SPECIFICATIONS ..........................................................................7-17.2 SoftwareSpecifications .......................................................................................7-27.3 MODEL AND SUFFIX CODES .............................................................................7-37.4 OPTIONAL ACCESSORIES ................................................................................7-37.5 Outline ..................................................................................................................7-47.6 Regulatory Compliance Statements .....................................................................7-5
Revision Information ........................................................................................i
1st Edition: July 2020All Rights Reserved, Copyright © 2020, Yokogawa Electric Corporation
1-1 <Introduction>
IM 01W06D01-01EN
1. Introduction Thank you for purchasing XS110A Wireless Communication Module. This manual provides important information and installation and maintenance instructions for using the XS110A Wireless Communication Module (Hereinafter, it is described as XS110A.) correctly and safely.The XS110A can be connected to an XS-series Measurement Module. The battery mounted on the XS110A supplies power to the connected Measurement Module.The function description, setting, operation, and maintenance of the XS-series are described in the Sushi Sensor Series Software Edition (IM01W06C01-01EN), so be sure to read it and use it correctly.TheSushiSensorSeriesSoftwareEdition(PDFfiles)candownloadfromourcompany home page (http://www.sushisensor.com/).
Table 1.1 Related DocumentsDocument Name Document No.
GeneralSpecificationsXS110A Wireless Communications Module
GS01W06D01-01EN
User's ManualSushi Sensor Series Software Edition
IM01W06C01-01EN
1-2 <Introduction>
IM 01W06D01-01EN
n Regarding This Manual • Thismanualshouldbeprovidedtotheenduser.• Thismanualandtheidentificationtagattachedonthepackingbox
are essential parts of the product; keep them in a safe place for future reference.
• Thecontentsofthismanualaresubjecttochangewithoutpriornotice.• Allrightsreserved.Nopartofthismanualmaybereproducedinanyform
without Yokogawa’s written permission.• Yokogawamakesnowarrantyofanykindwithregardtothismanual,
including,butnotlimitedto,impliedwarrantyofmerchantabilityandfitnessfor a particular purpose.
• Ifanyquestionarisesorerrorsarefound,orifanyinformationismissingfromthismanual,pleaseinformthenearestYokogawasalesoffice.
• Thespecificationscoveredbythismanualarelimitedtothoseforthestandardtypeunderthespecifiedmodelnumberbreak-downanddonotcovercustom-madeinstruments.Whenproductswhosesuffixcodeoroptional codes contain code “Z” and an exclusive document is attached, please read it along with this manual.
• Pleasenotethatchangesinthespecifications,construction,orcomponentpartsoftheinstrumentmaynotimmediatelybereflectedinthismanualatthe time of change, provided that postponement of revisions will not cause difficultytotheuserfromafunctionalorperformancestandpoint.
nSafety,Protection,andModificationofthisProduct• Thisproductisdesignedtobeusedbyapersonwithspecialized
knowledge.• Toprotecttheoperator,product,andsystemcontrolledbytheproduct,
observe the safety precautions described in this manual. If users handle contrary to these instructions, we cannot guarantee safety.
• TheModificationoftheproductisstrictlyprohibited.• Repairormodificationtothisinstrumentbycustomerwillcausea
malfunctionofexplosionprotectfunctionandhazardoussituation.Ifyouneedtorepairormodification,pleasecontactthenearestYokogawaoffice.
1-3 <Introduction>
IM 01W06D01-01EN
• Thefollowingsafetysymbolsareusedinthismanual:
WARNING
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesapotentiallyhazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjuryorphysicaldamage.Itmayalsobeusedtoalertagainst unsafe practices.
IMPORTANTIndicates that operating the hardware or software in this manner may damage it or lead to system failure.
NOTEDraws attention to information essential for understanding the operation and features.
n Trademarks• SushiSensorisaregisteredtrademarkofYokogawaElectricCorporation.• Theregisteredtrademarksortrademarksoftherespectivecompaniesin
the text do not bear the mark of TM or ®.
1-4 <Introduction>
IM 01W06D01-01EN
1.1 Safe Use of This Product• Usersofexplosionprotectedinstrumentsshouldreferfirstto“2.6Explosion
Protected Instrument”.• Theuseofthisinstrumentisrestrictedtothosewhohavereceived
appropriate training for the device.• Takecarenottocreatesparkswhenaccessingtheinstrumentorperipheral
devicesinahazardouslocation.• Repairormodificationtothisinstrumentbycustomerwillcausea
malfunctionofexplosionprotectfunctionandhazardoussituation.Ifyouneedtorepairormodification,pleasecontactthenearestYokogawaoffice.
1.2 Radio WavesThisproductisdesignatedasacertificationofconstructiontypeasawirelessfacilityfor800MHzbandand900MHzbandlow-powerdatacommunicationsystem of the Radio Act.Refer to “7.6 Regulatory Compliance Statements” for detail.• AreaCode2:RegionalparameterisEU868andfrequencyis863to
870MHz*1. • AreaCode3:RegionalparameterisUS915andfrequencyis902to
928MHz*2.• AreaCode4:RegionalparameterisAS923andfrequencyis919to
925MHz*2.*1: SwedenandGreecedonotallowfulluseofthe863to870MHzband. Detail of the restrictions, refer to EC Decision 2006/771/EC (as amended).*2: Availablefrequencybandsvarydependingonthecountry.
1-5 <Introduction>
IM 01W06D01-01EN
IMPORTANT• Duetothedesignatedcertificationofconstructiontype,usersmaybe
subjecttolegalpunishmentincaseofdisassemblingormodifyingthisproduct.
• PreventinginterferencewithotherwirelessstationsIndustrial,scientific,andmedicalequipment,aswellaslocalwirelessstations(licenserequired)andspecificlowpowerwirelessstations(licensenotrequired)foridentifyingmobileobjectsusedinfactoryproductionlines,usethesamefrequencybandasthisproduct.
• Checkthatlocalwirelessstationsandspecificlow-powerwirelessstations are not being used in the vicinity before using this product.
• Ifthisproductcausesradiointerferenceinalocalwirelessstation,stopthe emission of radio waves immediately. For details on how to prevent radiointerference,contactourserviceoffice.
1.3 Warranty• Thewarrantyshallcovertheperiodnotedonthequotationpresentedtothe
purchaser at the time of purchase. Problems occurring during the warranty period shall basically be repaired free of change.
• Ifanyproblemsareexperiencedwiththisproduct,thecustomershouldcontact the Yokogawa representative from which this product was purchasedorthenearestYokogawaoffice.
• Ifaproblemariseswiththisproduct,pleaseinformusofthenatureofthe problem and the circumstances under which it developed, including themodelspecificationandserialnumber.Anydiagrams,dataandotherinformation you can include in your communication will also be helpful.
• Thepartyresponsibleforthecostoffixingtheproblemshallbedeterminedby Yokogawa following an investigation conducted by Yokogawa.
1-6 <Introduction>
IM 01W06D01-01EN
n The purchaser shall bear the responsibility for repair costs, even during the warranty period, if the malfunction is due to:
• Improperand/orinadequatemaintenancebythepurchaser.• Malfunctionordamageduetoafailuretohandle,use,orstorethisproduct
inaccordancewiththedesignspecifications.• Useofthisproductinquestioninalocationnotconformingtothestandards
specifiedbyYokogawa,orduetoimpropermaintenanceoftheinstallationlocation.
• FailureordamageduetomodificationorrepairbyanypartyexceptYokogawa or an approved representative of Yokogawa.
• Malfunctionordamagefromimproperrelocationofthisproductinquestionafter delivery.
• Reasonofforcemajeuresuchasfires,earthquakes,storms/floods,thunder/lightening, or other natural disasters, or disturbances, riots, warfare, or radioactive contamination.
2-1 <Notes on Handling>
IM 01W06D01-01EN
2. Notes on HandlingThe XS110A is fully factory-tested before shipment. When the XS110A is delivered, check the appearance for damage. Thissectiondescribestheprecautionsrequiredtohandlethisproduct.Beforeuse, read this section thoroughly. For information about other items, refer to the relevant sections.
2.1 ChecktheModelandSpecificationsThemodelnameandspecificationsarewrittenonthe nameplate attached to the case. Verify that the specificationindicatedinthe“ModelandSuffixCode”inGeneralSpecifications“GS01W06D01-01EN”complieswiththespecificationswrittenontheordersheet.
2.2 Transport To prevent damage while in transit, leave the XS110A in the original shipping container until it reaches the installation site.
2.3 Storage When an extended storage period is expected, observe the following precautions.(1) Chooseastoragelocationthatsatisfiesthefollowingrequirements.
• Alocationthatisnotexposedtorainorwater.• Alocationsubjecttoaminimumofvibrationorimpact.• Thefollowingtemperatureandhumidityrangearerecommended.
- Temperature: –40 to 85°C (–40 to 185°F)- Humidity: 0 to 100% RH (non-condensation)
(2) When storing the XS110A, repack it carefully in the packaging that it was originally shipped with.
(3) Preferably remove the batteries for storage. For maximum battery life, the storage temperature should not exceed 30°C.
F01.ai
XS110A
2-2 <Notes on Handling>
IM 01W06D01-01EN
NOTEWhen storing this product over a long period, it is recommended to put the instrument in OFF Mode to conserve the battery. For details on how to switch to OFF Mode, refer to “IM 01W06C01-01EN”.
2.4 Selecting the Installation LocationThis product is designed to withstand severe environmental conditions. However, to ensure that it will provide years of stable and accurate performance, take the following precautions when selecting the installation location.
n Wireless Communication Install where are no obstacles for radio waves such as walls or pipes around the product as possible.
n Ambient Temperature Avoidlocationssubjecttowidetemperaturevariationsorasignificanttemperature gradient. If the location is exposed to radiant heat from plant equipment,provideadequatethermalinsulationand/orventilation.
n Ambient Atmospheric Do not install the product in a location with a corrosive atmosphere. If this cannotbeavoided,ensurethereisadequateventilation.
n Shock and Vibration It is designed to be resistant to shock and vibration. However, it is recommendedthattheXS110Abeinstalledinalocationthatissubjecttoaminimum amount of impact and vibration.
2-3 <Notes on Handling>
IM 01W06D01-01EN
2.5 Restrictions on Use of Radio Transceivers IMPORTANTAlthoughthisproducthasbeendesignedtoresisthighfrequencyelectricalnoise, if a radio transceiver is used near this product or its external wiring, thisproductmaybeaffectedbyhighfrequencynoisepickup.Totestthis,start from a distance of several meters and slowly approach this product with the transceiver while observing the measurement loop for noise effects.Thereafterusethetransceiveroutsidetherangewherethenoiseeffectswerefirstobserved.
2.6 Explosion Protected Instrument2.6.1 ATEX Intrinsic SafetyTechnical data:• Certificatenumber:DEKRA20ATEX0024X• Applicablestandards:ENIEC60079-0:2018,EN60079-11:2012• Exmarking: II 2 G Ex ib IIC T4 Gb• Ambienttemperature:–40to75°C(–40to167°F)*
*:Additionally,limitedbytheambienttemperaturerangeoftheequipmentconnectedtoXS110A.
• Electricalparameters: Connector Uo=6.88V,Io=1.54A,Po=0.3W,Co=10μF,Lo=3μH• Enclosure:IP66/IP67whenaccordancewithEN60529whencombined
withcertifiedequipment.
Certificationinformation:
WARNING
Amodificationoftheequipmentwouldnolongercomplywiththeconstructiondescribedinthecertificatedocumentation.
2-4 <Notes on Handling>
IM 01W06D01-01EN
Control drawing:
F02.ai
XS110AWireless communication module
Hazardous Location
IS Apparatus
Uo: 6.88 V Io: 1.54 APo: 0.3 WCo: 10 µFLo: 3 µH
Ui ≥ Uo Ii ≥ Io Pi ≥ Po Ci ≤ Co Li ≤ Lo
20
Connector
Specificconditionsofuse:Precautionsshallbetakentominimizetheriskfromelectrostaticdischargeofnon-metallic parts.
WARNING
• POTENTIALELECTROSTATICCHARGINGHAZARD–SEEINSTRUCTIONS
• DONOTOPENWHENANEXPLOSIVEATMOSPHEREISPRESENT• USEONLYSPECIFIEDBATTERY–SEEINSTRUCTIONS
Installation:TheequipmentmustbeinstalledinaccordancewithEN60079-14,localrequirements,andthecontroldrawing.
2-5 <Notes on Handling>
IM 01W06D01-01EN
Operation:
WARNING
• Whentheequipmentisusedinhazardouslocations,avoidanyactionswhich generate electrostatic charges, such as rubbing with a dry cloth.
• WhenusingSushiSensorAPPtotheexplosionprotectedinstrument,the Android device must comply with the following. WhenusingtheNFClinkinanon-hazardousarea,themaximum
magneticfieldstrengthgeneratedbytheAndroiddeviceis18[A/m(r.m.s.)] or less (Compliant with ISO / IEC 14443).
WhenusingNFClinkinahazardousarea,onlyAndroiddevicesconfirmedbyYokogawaElectricCorporationcanbeused.
If additional information and approvals for Android device are required,contactaYokogawarepresentative.
Maintenance and repair:
WARNING
OnlypersonnelauthorizedbyYokogawaElectricCorporationcanrepairtheequipment.
Replacing the Battery:
WARNING
Be sure to replace the battery in a safe location. Doing so in an explosive area could cause an explosion.
Use the following batteries.TL-5930/S,SL-2780/S(Tadiran)orSB-D02(Vitzrocell)
2-6 <Notes on Handling>
IM 01W06D01-01EN
2.6.2 IECEx Intrinsic SafetyTechnical data:• Certificatenumber:IECExDEK19.0027X• ApplicationStandard:IEC60079-0Ed.7.0(2017),
IEC60079-11Ed.6.0(2011)• EXmarking:ExibIICT4Gb• Ambienttemperature:–40to75°C(–40to167°F)*
*:Additionally,limitedbytheambienttemperaturerangeoftheequipmentconnectedtoXS110A.
• Electricalparameters: Connector Uo=6.88V,Io=1.54A,Po=0.3W,Co=10μF,Lo=3μH• Enclosure:IP66/IP67whenaccordancewithIEC60529whencombined
withcertifiedequipment.
Certificationinformation:
WARNING
Amodificationoftheequipmentwouldnolongercomplywiththeconstructiondescribedinthecertificatedocumentation.
Control drawing:
F03.ai
XS110AWireless communication module
Hazardous Location
IS Apparatus
Uo: 6.88 V Io: 1.54 APo: 0.3 WCo: 10 µFLo: 3 µH
Ui ≥ Uo Ii ≥ Io Pi ≥ Po Ci ≤ Co Li ≤ Lo
20
Connector
2-7 <Notes on Handling>
IM 01W06D01-01EN
Specificconditionsofuse:Precautionsshallbetakentominimizetheriskfromelectrostaticdischargeofnon-metallic parts.
WARNING
• POTENTIALELECTROSTATICCHARGINGHAZARD–SEEINSTRUCTIONS
• DONOTOPENWHENANEXPLOSIVEATMOSPHEREISPRESENT• USEONLYSPECIFIEDBATTERY–SEEINSTRUCTIONS
Installation:TheequipmentmustbeinstalledinaccordancewithIEC60079-14,localrequirements,andthecontroldrawing.
Operation:
WARNING
• Whentheequipmentisusedinhazardouslocations,avoidanyactionswhich generate electrostatic charges, such as rubbing with a dry cloth.
• WhenusingSushiSensorAPPtosettheparameteroftheexplosionprotected instrument, the Android device must comply with the following. WhenusingtheNFClinkinanon-hazardousarea,themaximum
magneticfieldstrengthgeneratedbytheAndroiddeviceis18[A/m(r.m.s.)] or less (Compliant with ISO / IEC 14443).
WhenusingNFClinkinahazardousarea,onlyAndroiddevicesconfirmedbyYokogawaElectricCorporationcanbeused.
If additional information and approvals for Android device are required,contactaYokogawarepresentative.
2-8 <Notes on Handling>
IM 01W06D01-01EN
Maintenance and repair:
WARNING
OnlypersonnelauthorizedbyYokogawaElectricCorporationcanrepairtheequipment.
Replacing the Battery:
WARNING
Be sure to replace the battery in a safe location. Doing so in an explosive area could cause an explosion.
Use the following batteries.TL-5930/S,SL-2780/S(Tadiran)orSB-D02(Vitzrocell)
3-1 <Component Names>
IM 01W06D01-01EN
3. Component Names
Nameplate
Straphole
Battery holder
Battery holderfixing screw
Cable
F04.ai
NFCinterface
Measurement Module mounting screw
Case
Mainbody
Front Back
Interior
4-1 <Installation>
IM 01W06D01-01EN
4. InstallationThe XS110A does not include batteries when shipped from the factory. Install the battery to the XS110A according to the procedure in Section 6.1. After installing the battery, mount the XS110A on the Measurement Module. Refer to the User’s Manual of the Measurement Module connected to the XS110A for installation precautions.RefertoChapter7"GeneralSpecifications"fortheambientconditionsoftheinstallation site.
5-1 <Operation>
IM 01W06D01-01EN
5. Operation To perform the setting and status check of the product, use an Android device with the NFC interface. Download Sushi Sensor App from Google Play.Sushi Sensor App provides the following functions.• Networksetting• Sensorsetting• Statuscheckofcommunication,sensor,batterylife,etc.• SwitchtoOFFMode
For details, refer to “IM 01W06C01-01EN”. CheckthefirmwareversionofMeasurementModulewithSushiSensorAppandupdateittothelatestfirmwarebeforeuse.
6-1 <Maintenance>
IM 01W06D01-01EN
6. Maintenance
6.1 Replacing the BatteryThe XS110A can be replaced with a new battery. The XS110A does not include batteries when shipped from the factory. Install the battery in the XS110A according to the procedure in this section. If the XS110A is installed on the Measurement Module, remove the XS110A according to the user manual of the Measurement Module. Refer to 6.2 for the battery that can be mounted on the XS110A.
6-2 <Maintenance>
IM 01W06D01-01EN
nWorkflowIMPORTANT
• Thisproductcontainspartsthatcanbedamagedbystaticelectricity.When replacing a battery, take precautions such as using a grounded wrist strap to avoid handling electronic parts or touching the board circuit patterns.
• WhenputtingonorremovingtheCase,paygreatattentiontotheenvironmental conditions to prevent dust and water droplets entering the product.
• Takesufficientcarenottoapplyexcessiveforcetothecircuitboard,hittheboardwithtools,orstickforeignobjectsordirttotheboard.
• Becarefulnottoforcethecabletoscratchit,breakit,orpullitoutofthebattery holder.
Follow the procedure below to replace the battery.1. Loosen the case retaining screw (2 places) on the underside of the
XS110A.2. Removethecaseandbody.Ifitisdifficulttoopenthecasebyhand,usea
flatbladescrewdriverasshowninFig.6-2.Thecasecanbeeasilyopenedby holding it in the groove between the case and the body and pushing it upward.
3. While holding the top surface of the battery holder with your hand, loosen thebatteryholderfixingscrew(2places)alternately.
4. If the battery is stored, remove it by lifting the battery that is stored with the battery holder.
5. Insert the new replacement battery into the battery holder with the positive electrode facing up, as shown in Figure 6-3.
6. With the top of the battery holder held down by hand, alternately tighten the batteryholderfixingscrew(2places)withatorqueof1.4N·m.
7. Put the case into the body without any gap.8. Tightenthecasefixingscrew(2places)onthebottomoftheXS110Atofix
thecasewithatorqueof1.4N·m.9. InitializethebatterylifeusingSushiSensorApp.Fordetailsabouthowto
initializethebatterylife,referto“IM01W06E01-11EN”.
6-3 <Maintenance>
IM 01W06D01-01EN
case fixing screw
F05.ai
Figure 6-1 Bottom of XS110AF06.ai
Figure 6-2 Removing the case and body
F07.ai
Figure 6-3 How to insert the battery
6-4 <Maintenance>
IM 01W06D01-01EN
6.2 Handling the BatteryThis product uses one lithium thionyl chloride primary battery. A single battery contains approximately 5 grams of lithium. Under normal conditions, the battery materials are self-contained and are not reactive as long as the battery integrity is maintained. Care should be taken to prevent thermal, electrical or mechanical damage. Battery should be stored in a clean and dry area. For maximum battery life, storage temperature should not exceed 30°C.
WARNING
handling of batteries Thefollowingprecautionsmustbeobservedtosafelyandeffectivelyuseabatterypack.Improperusemayleadtofluidleakage,excessiveheat,ignition, or explosion.• Neverchargeit.• Don'tcutshort-circuitit.• Donotdisassemble,transform,ormodifyit.• Donotheatitorthrowitinafire.• Donotsoakitinfreshwaterorseawater.
CAUTION
Observe the following precautions for the safe disposal of battery.• Donotincineratethebattery,anddonotexposeittoahigh
temperatureof100°Cormore.Thismayleadtofluidleakageorexplosion.
• Disposeofthebatteryaccordingtolowsandregulations.
6-5 <Maintenance>
IM 01W06D01-01EN
n Batteries PartNo.:F9915NR(2batteries)Alternatively, following batteries may be purchased and used.• TadiranTL-5930/SorSL-2780/S• VITZROCELLSB-D02
Transportation of products containing a lithium battery:This product contains a lithium battery. When transporting this product with the battery installed, set this product to OFF mode to prevent the battery from draining. For details about how to change to OFF mode, refer to “IM 01W06C01-01EN”. Transportation of primary lithium batteries is restricted by regulations issued by the U.S. Department of Transportation, the International AirTransportAssociation(IATA),theInternationalCivilAviationOrganization(ICAO), and the European Ground Transportation of Dangerous Goods (ARD). It is the responsibility of the shipper to ensure compliance with these and any otherlocalrequirements.Consultcurrentregulationsandrequirementsbeforeshipping.
How to replace and dispose of the battery:This is an explanation about the EU Battery Directive. This directive is only valid in the EU.The battery is included in this product.When you remove the battery from this product and dispose of them,discard them in accordance with domestic law concerning disposal.Take the right action on waste batteries,because the collection system in the EU on waste batteries are regulated.Battery type: Primary lithium-thionyl chloride battery
Notice:The symbol (see above) means they shall be sorted out and collected as ordained in the EU Battery Directive.
How to remove battery safely:Refer to subsection 6.1 “Replacing the Battery”.
7-1 <GeneralSpecifications>
IM 01W06D01-01EN
7. GeneralSpecificationsPlease refer to “GS 01W06D01-01EN” for the latest information.
7.1 STANDARD SPECIFICATIONS
n WIRELESS SPECIFICATIONS
Communication protocol:LoRaWAN Class A, EU868,AS923,US915
Data Rate:250to11000bps**:Availabledataratevarydependingonthe
country.
Frequency:[Areacode2]863to870MHz*1
[Areacode3]902to928MHz*2
[Areacode4]919to925MHz*2*1:Thiswirelessfrequencycanbeused
throughout, Europe, although there are some restrictions in Sweden and Greece.
*2:Availablefrequencybandsvarydependingon the country.
Radio Security:AES 128-bit encryption
RF Transmitter Power:Max. 7 dBm
Antenna:Built-in Omnidirectional antenna
n POWER SUPPLY SPECIFICATIONS
Battery:Lithium thionyl chloride battery (sizeD):1unitRated voltage: 3.6 VRatedcapacity:19Ah
n PERFORMANCE SPECIFICATION
Update Time:1 minute to 3 days
Battery characteristics:The battery life of XS110A depends on connected Measurement Module. Refer to the General SpecificationsofeachMeasurement Module.
n FUNCTIONAL SPECIFICATION
Output signal:LoRaWAN EU868;EU,AS923;SoutheastAsia,US915;NorthAmerica
NFC Interface:NFC Forum Type 2 Tag
Diagnostics Function:Battery alarm, internal temperature, wireless communication failures, memory failures, Measurement Module connection failure
Software Download Features:Allows the user to update the software of the sensor via the NFC interface.
7-2 <GeneralSpecifications>
IM 01W06D01-01EN
Power supply to the Measurement Module:
Supply voltage: 3.3 VSupply current: 50 mA
n INSTALLATION ENVIRONMENT
Ambient Temperature Limits:Operating: –40 to 85°C (–40 to 185°F)Storage: –40 to 85°C (–40 to 185°F)
Ambient Humidity:0 to 100% RH (non-condensation)
Temperature Gradient:Operating: Within ±/10°C/h Storage: Within ± 20°C/h
Altitude: Up to 3000 m
Vibration Resistance:0.21mmP-P(10to60Hz),3G(60to2kHz)
Shock Resistance:50 G 11 ms
n PHYSICAL SPECIFICATIONS
Housing Material:Plastic (PC)
Weight:300g(0.66lb)**:Withoutbattery
7.2 Software Specifications
n Sushi Sensor AppThis software is used to perform the setting and status check of this product via the NFC interface.
Operating Environment:
Item Recommended System Requirements
OS Android 5.1.1 or higher
CPU Snapdragon 800 or better
Resolution 1280 x 720 dots or more
NFC Readers, Writer
GPS Optional
Note of Available Android Device:When using Sushi Sensor APP to the Android device must comply with the following.• WhenusinganNFClinkin
anon-hazardousarea,themaximummagneticfieldstrength generated by the Android device is 18 A/m (r.m.s.) or less (Compliant with ISO / IEC 14443).
• WhenusinganNFClinkinahazardousarea,onlyanAndroiddeviceconfirmedbyYokogawa Electric Corporation can be used.
• Ifadditionalinformationandapprovals for Android devices arerequired,contactaYokogawa representative.
7-3 <GeneralSpecifications>
IM 01W06D01-01EN
7.3 MODEL AND SUFFIX CODESModel SuffixCodes Description
XS110A Wireless Communication ModuleInter-module communication -A Digital communication for XS-series
Area2 Europe EU868 3 NorthAmericaUS9154 SoutheastAsiaAS923
Type00 Generalpurpose*1K2 ATEXintrinsicsafety*2S2 IECExintrinsicsafety*3
― -A Always AHousing material 5 Plastic (PC)Power source D Battery powered (Battery not included)― A Always A
*1:ApplicablewhenAreaCodeis3.*2:ApplicablewhenAreaCodeis2or4.*3:ApplicablewhenAreaCodeis4.
7.4 OPTIONAL ACCESSORIESItem Parts Number Description
Batteries*1 F9915NR Lithium-thionylchloridebatteries*2,2pieces*3
*1:Alternatively,TadiranTL-5930/S,SL-2780/SorVITZROCELLSB-D02batteriescanbepurchasedfromyour local distributor.
*2:TadiranTL-5930/S*3:ThisproductworkswithonesizeDbattery,buttheaccessoryisasetoftwo.
7-4 <GeneralSpecifications>
IM 01W06D01-01EN
7.5 Outline l Main body
Units: mm (approx. inch)
Measurement Module mounting screw
NFC Interface
133.
5 (5
.26)
ø68 (2.68)
Case fixing screw
Measurement Module connector
F08.ai
7-5 <GeneralSpecifications>
IM 01W06D01-01EN
7.6 Regulatory Compliance StatementsThisproductsatisfiesthefollowingstandards.* Pleaseconfirmthataninstallationregionfulfillsanapplicablestandard.
Ifadditionalregulatoryinformationandapprovalsarerequired,contactaYokogawa representative.
Telecommunication Compliance:
n RE Directive (EU Countries)Hereby,YokogawaElectricCorporationdeclaresthattheradioequipmenttypeXS110A complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:https://partner.yokogawa.com/global/
n FCC compliance (United States)FCC ID: SGJ-WFC017FCC ApprovalThisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowing two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Co-located:Thistransmittermustnotbeco-locatedoroperatedinconjunctionwithanyother antenna or transmitter.
FCC WARNINGChangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatetheequipment.
7-6 <GeneralSpecifications>
IM 01W06D01-01EN
NOTEThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClass A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference whentheequipmentisoperatedinacommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterferenceathisownexpense.
RF Exposure Compliance:ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironmentandmeetstheFCCradiofrequency(RF)ExposureGuidelines.Thisequipmentshouldbeinstalledandoperatedkeepingtheradiator at least 20 cm or more away from person’s body.
n ISED compliance (Canada)IC:8999A-WIC016This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).Operationissubjecttothefollowingtwoconditions:(1) This device may not cause interference.(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
7-7 <GeneralSpecifications>
IM 01W06D01-01EN
French:L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conformeauxCNRd’Innovation,SciencesetDéveloppementéconomiqueCanada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :(1) L’appareil ne doit pas produire de brouillage;(2) L’appareildoitacceptertoutbrouillageradioélectriquesubi,mêmesile
brouillage est susceptible d’en compromettre le fonctionnement.
RF Exposure Compliance:ThisequipmentcomplieswithISEDradiationexposurelimitssetforthforanuncontrolledenvironmentandmeetsRSS-102oftheISEDradiofrequency(RF)Exposurerules.Thisequipmentshouldbeinstalledandoperatedkeepingthe radiator at least 20 cm or more away from person’s body.
French:Cetéquipementestconformeauxlimitesd’expositionauxrayonnementsénoncées pour un environnement non contrôlé et respecte les règles d’expositionauxfréquencesradioélectriques(RF)CNR-102del’ISDE.Cetéquipementdoitêtreinstalléetutiliséengardantunedistancede20cmouplus entre le radiateur et le corps humain.
CE Conformity:TheAuthorizedRepresentativeforthisproductintheEEAis:
Yokogawa Europe B.V. Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDS.
RoHS Directive:EN50581
7-8 <GeneralSpecifications>
IM 01W06D01-01EN
RE Directive:Safety:EN61010-1(Indoor/Outdooruse),EN62479(1) Pollution Degree 2
“Pollutiondegree”describesthedegreetowhichasolid,liquid,orgas which deteriorates dielectric strength or surface resistivity is adhering. “2” applies to normal indoor atmosphere. Normally, only non-conductive pollution occurs.Occasionally, however, temporary conductivity caused by condensation must be expected.
(2) Installation Category I“Overvoltage category (Installation category)” describes a number whichdefinesatransientovervoltagecondition.Itimpliestheregulation for impulse with stand voltage. “I” applies to electrical equipmentwhichissuppliedfromthecircuitwhenappropriatetransient overvoltage control means (interfaces) are provided.
EMC: EN301489-1,EN301489-3,EN61326-1ClassATable2, EN61326-2-3, EN55011 Class A
CAUTION
This instrument is a Class A product, and it is designed for use in the industrial environment. Please use this instrument in the industrial environment only.
Radio Spectrum:EN 300 220-2 (Band h1.3 in table 1 of CEPT ERC Rec. 70-03), EN 300 330
The full text of the EU declaration of conformity is available at the following internet address:https://partner.yokogawa.com/global/
7-9
IM 01W06D01-01EN
Canadian Safety Standards:CAN/CSA-C22.2 No.61010-1CSA-C22.2No.94.2IEC60529Pollution degree 2Overvoltage category I
Degrees of Protection: IP66/IP67 and Type 4XApply when connected to the Measurement Module.
n Waste Electrical and Electronic Equipment (WEEE), Directive
(This directive is valid in the EU member states.)ThisproductcomplieswiththeWEEEDirectivemarkingrequirement.The following marking indicates that you must not discard this electrical/electronic product in domestic household waste.Product Category WithreferencetotheequipmenttypesintheWEEEdirective,thisproductisclassifiedas“Smallequipment”.Do not dispose of this product in domestic household waste.When disposing of products in the EU, contact your local Yokogawa Europe B. V.office.
i
IM 01W06D01-01EN
Revision Information Title: XS110A Wireless Communication Module
Reference Number: IM 01W06D01-01EN
Edition Date Page Revision Item1st July 2020 ― New publication
YOKOGAWA ELECTRIC CORPORATIONHeadquarters9-32, Nakacho, 2-chome, Musashino-shi, Tokyo, 180-8750 JAPANPhone : 81-422-52-5555
Branch Sales OfficesOsaka, Nagoya, Kurashiki, Hiroshima, Fukuoka, Kitakyusyu
YOKOGAWA CORPORATION OF AMERICAHead Office12530 West Airport Blvd, Sugar Land, Texas 77478, USAPhone : 1-281-340-3800 Fax : 1-281-340-3838
Georgia Office2 Dart Road, Newnan, Georgia 30265, USAPhone : 1-800-888-6400 Fax : 1-770-254-0928
YOKOGAWA EUROPE B. V.Euroweg 2, 3825 HD Amersfoort, THE NETHERLANDSPhone : 31-88-4641000 Fax : 31-88-4641111
YOKOGAWA ENGINEERING ASIA PTE. LTD.5 Bedok South Road, Singapore 469270, SINGAPOREPhone : 65-6241-9933 Fax : 65-6241-9919
Printed in Japan