xgard overview - crowcon detection instruments ltd
TRANSCRIPT
Xgard Overview
© 2018 Crowcon Detection Instruments. All rights reserved.
Fixed – Detector head range overview
Capability
Mar
ket P
rice
Xgard & Xsafe
Xgard IR
Flamgard+
Txgard / Txgard IS
Xgard Bright
Xgard IQ
IRmax
Range of Detector heads
Infra red Xgard
Flammable gas detector head with display
Toxic gas detector heads with display
Addressable detector with display
Intelligent detector and transmitter
Infra red Hydrocarbon detector
Analog 4-20mA Non intrusive / Display
SIL certification.
Remote sensor / display
© 2018 Crowcon Detection Instruments. All rights reserved.
Xgard Summary
The Xgard range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.
Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe, or safe area formats for use in all environments, whatever the classification.
Range of fixed gas detectors with wide range of sensor & gas detection options that provide low cost of ownership with
rugged, reliable and highly versatile
Available gases
Contact us for more gas / sensor options
NH3 AsH3 Br2 CO Cl2 B2H6 C2H4O F2 O3 H2 HCI HCl HF H2S NO
PH3 NH3 SO2 VOC O2 C4H10 C4H8 CO2 C2H50H C2H4 C6H14 LPG CH4 NO2 O3
Key Features
© 2018 Crowcon Detection Instruments. All rights reserved.
Wide range of sensors
• Entry level fixed head for wide range of sensors options including
catalytic, electrochemical and infrared.
• Thermal conductivity detector (Xgard Type 6) was obsoleted in
2019. Spare support is available till 2026.
• Includes exotic gas options e.g jet fuel, leaded petrol and vapours
containing halogens
• Gas type, sensor range (correspond to analogue output) and part
number for spares are listed on the label.
• Year of manufacture is also reflected on label.
© 2018 Crowcon Detection Instruments. All rights reserved.
Low cost of ownership
• Xgard is available in various casing options including high-grade
alloy, stainless steel or chemically resistant GRN polymer
• Design for easy installation and maintenance to keep cost down
• Replacement of sinters and sensor is simple. Spare sensors
simply plug-in
• Many spare parts are common to all Xgard models, which keeps
spares inventory to a minimum.
© 2018 Crowcon Detection Instruments. All rights reserved.
Flexible installation options
Spray deflectors
Mounting brackets
Duct mounting kits
Flow adaptors
Sun-shades
Calibration adaptors
Collector cones
Spigot glands
Carbon filters
© 2018 Crowcon Detection Instruments. All rights reserved.
Full range of certification
• Xgard has full range of certification including
ATEX, IECEx and UL
• Validated to the functional safety standard IEC
61508 (SIL 1 to SIL 3)
• Marine certification – Inmetro for Type 2 to 5.
• Xsafe is low cost non-certified pellistor sensor to
suit safe installations e.g. industrial boilers,
kitchen, gas-fired oven.
Certification
© 2018 Crowcon Detection Instruments. All rights reserved.
Type 1 Type 2 Type 3 Type 4 Type 5 Xgard IR
ATEX: II 1 GExia IIC T4 Ga
(Tamb -40 to +55°C)UL/cUL: Class I, Div.
1Groups A, B, C, D
IECExEAC
ATEX: II 2GDExd IIC T6 Gb (Tamb -
40 to +50°C)UL: Class I, Div. 1
Groups B, C, DIECExEAC
ATEX: II 2 GDExd IIC T4 Gb
(Tamb -40 to +80°C)Exd IIC T6 Gb (Tamb -40
to +50°C)Ex tb IIIC
T180°C DbUL: Class I, Div. 1
Groups B, C, DIECExEAC
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to
+150°C)
ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)Exd IIC T4 Gb (Tamb -40
to +80°C)Ex tb IIIC
T180°C DbUL: Class I, Div. 1
Groups B, C, DIECExEAC
ATEX: Ex II 2GDEx d IIC T6 Gb Ex tb
IIIC T80°C Db (-40°C ≤ Tamb ≤ + 50°C)
Ex d IIC T4 Gb Ex tb IIIC T110°C Db (-40°C
≤ Tamb ≤ + 80°C)IECEx: Ex d IIC T6 Gb Ex tb IIIC T80°C Db (-40°≤ Tamb ≤ + 50°C)Ex d IIC T4 Gb Ex tb
IIIC T110°C Db (-40°≤ Tamb ≤ + 80°C)
UL Class 1 Div 1, Groups B, C, D
EMC compliance EN 50270 FCC Part 15 ICES- 003
Specification
© 2018 Crowcon Detection Instruments. All rights reserved.
Type 1 Type 2 Type 3 Type 4 Type 5/ XSafe Xgard IR
Sensor type Electrochemical Catalytic bead316 S/S sensor housing with
catalytic beadsCatalytic bead Infrared
Operating temperature
-40 to +50 °C-20 to +50°C(-4 to 122°F)
-40 to +80°C -20 to +150°C -20 to +55°C -20 to +55°C (-40 to 122 °F) (-40 to 176°F) (-4 to 302°F) (-40 to 131°F) (-4°F to 131°F)
(sensor dependant)
Humidity 10 to 95% RH non-condensing 0-99% RH non-condensing0 to 95% RH non-
condensing
Repeatability Zero drift
<2% FSD (Typical)<2% FSD per Month (Typical)
Response timeT90 <15s OxygenT90 <30s to 120s
Toxic(sensor dependant)T90 <15s (Typical)
Operating voltage 8-30V dc 2.0V dc +/- 0.1V (Typical) 10-30V dcPower requirements
24mA maximum 300mA (Typical) 50mA at 24V dc 1.2W
Electrical output 2- wire 4-20mA (current sink)3- wire mV bridge 3- wire mV bridge 3- wire 4-20mA Typical signal: 12-15mV/ %LEL CH4
Typical signal: >10mV/%LEL CH4
(current sink or source)
© 2018 Crowcon Detection Instruments. All rights reserved.
Type 1 Type 2 Type 3 Type 4 Type 5/ XSafe Xgard IR
Size 156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)195 x 166 x
111mm (7.6 x 6.5 x 4.3 inches)
156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight
Nylon: 0.5 kgAluminium: 1kg
(2.2lbs)
1.5 kg (3.3lbs)
Aluminium: 1kg (2.2lbs)
Alloy: 1kg (2.2lbs)316 Stainless steel: 3.1kg (6.8lbs)
Stainless steel: 3.1kg (6.8lbs)
S/S: 3.1kg (6.8lbs)
Enclosure material
ATEX certified: Glass reinforced nylon or 316 S/SUL Certified:
Aluminium or 316 S/S
Aluminium or 316 Stainless
SteelAluminium Aluminium or 316 Stainless Steel
Ingress protection
IP65 IP54 IP65
Cable entries 1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations 0.5 to 2.5mm2
Servicing
© 2018 Crowcon Detection Instruments. All rights reserved.
Xgard Calibration
• Calibration of Xgard requires opening of detector cover,
user will need to disable alarm at control panel before
calibration.
• Tools required include flow adapter, multi-meter and
calibration gas (contact Crowcon for supply of calibration
gas)
• Follow Crowcon manual for calibration steps and
frequency of calibration
• Sensor replacement is simple, just plug in sensor module
• Many spare parts are common to all Xgard models, only
sensor module and amplifier PCB are unique to gas
types.
Summary
© 2018 Crowcon Detection Instruments. All rights reserved.
Key attributes and decision points
❖ Workhorse model with wide selection of sensors, enclosure materials and
mounting accessories
❖ mA or mV output only. Units comes without display or relays
❖ Easy replacement of spares and boards
❖ Intrusive calibration, which means hot work permit will be required if Xgard is
installed in a hazardous area.
© 2018 Crowcon Detection Instruments. All rights reserved.
Xgard Summary
The Xgard range is a comprehensive selection of fixed point gas detectors that meet the diverse requirements for gas detection in industries throughout the world. This includes many water treatment, oil and gas, power, research facility and manufacturing installations.
Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe, or safe area formats for use in all environments, whatever the classification.
Range of fixed gas detectors with wide range of sensor & gas detection options that provide low cost of ownership with
rugged, reliable and highly versatile
Available gases
Contact us for more gas / sensor options
NH3 AsH3 Br2 CO Cl2 B2H6 C2H4O F2 O3 H2 HCI HCl HF H2S NO
PH3 NH3 SO2 VOC O2 C4H10 C4H8 CO2 C2H50H C2H4 C6H14 LPG CH4 NO2 O3