XEDS/XDS • DISTRIBUTION EQUIPMENTCIRCUIT BREAKER ENCLOSURES
DE8
XDS-2003 XEDS-30
Lis ted - F i le E53290
Cer t i f i ed - F i le LR1171
See f i les for de ta i ls or ca l l K i l la rk .
®
Applications• Hazardous areas due to the presence
of flammable gases or vapors, com-bustible dusts or easily ignitable fibersor flyings
• Use in accordance with the NEC/CECwhere a horsepower rated quic make-quick break disconnect means for amotor and its controller is permitted
30-60-100-200 Amp Housing • External handle is vault type with stan-
dard provisions for locking in “OFF”position with up to three padlocks
• Provisions for locking in “ON” position available as factory modification (add suffix SU40 to catalog number)
• Enclosure and external handle is cast copper-free aluminum alloy (lessthan 4/10 of 1%)
• Cover bolts are stainless steel• Cutler-Hammer Type-DS Switches
30-60-100 Amp Housing • Two cast conduit hubs; one top and
one bottom• Internal disconnect handle mechanism
is a sliding plate mounted to the cover
200 Amp Housing • Two drilled and tapped conduit
openings, one top and one bottom• Custom drilled and tapped conduit
openings available on any of the four sides. (See Conduit Opening Data Chart, page E34, or consult factory.)
• Drilled and tapped holes are providedwith close-up plugs for field assemblyof drain and breather
• Handle mechanism interlocks with disconnect switch to prevent openingof enclosure when in the “ON” position
• Aluminum hinges are supplied asstandard on left side of all 200 AMPassemblies
X E D S E L E C T R I C A L R AT I N G S
MAXIMUM HORSEPOWER–THREE PHASE–3-POLE120 VAC
5
10
15
–
240 VAC10
20
30
60
480 VAC20
40
75
125
600 VAC25
60
75
150
250 VDC7-1 ⁄2
15
25
40
SUFFIX NUMBER DESCRIPTION
M O D I F I C AT I O N S
A B C D E F G H J
8-3/8" 8-3/4" 7/16" 10-1/4" 7-3/8" 11-7/8" 1-3/8" 6-7/8" 2"(213) (222) (11) (260) (187) (302) (35) (175) (51)
10-7/8" 9-1/8" 7/16" 13-7/8" 7-3/4" 16" 1-3/4" 7" 2"(276) (232) (11) (352) (197) (406) (44) (178) (51)
14-1/2" 13-7/8" 1/2" 22" 15" — 3-1/8" 12-7/8" —(368) (352) (13) (559) (381) (79) (327)
CATALOGNUMBER
XEDS-A
XEDS-B
XDS000C
X E D S D I M E N S I O N S
HUBSIZE
1-1/4"
2"
3"
Dimensions
CATALOG NUMBERENCLOSURE ENCLOSURE WITH ENCLOSURE WITH ENCLOSURE ONLY SWITCHWITH SWITCH AND SWITCH AND TWO (WITHOUT SWITCH OR RATINGSWITCH AUXILIARY CONTACTS AUXILIARY CONTACTS AUXILIARY CONTACTS)
X E D S D I S C O N N E C T S W I T C H E S
XEDS-30
XEDS-60
XEDS-1001
XDS-2003
XEDS-30A
XEDS-60A
XEDS-100A1
XDS-2003A
XEDS-30AA
XEDS-60AA
XEDS-100AA1
XDS-2003AA
XEDS-A
XEDS-B
XEDS-B1
XDS000C
30
60
100
200
Auxiliary switch kits are available for separate con-trol circuit applications. Each auxiliary switch hasone normally open and one normally closed con-tact. Each switch includes three soldered, identi-fied leads. Rated 15 amps at 250 volts maximum.
1 Due to wire gutter space, this unit must be wired with incoming (line) connection through the top hub and outgoing (load) connection to the bottom hub.
Class I, Div. 1 & 2, Groups C,DClass l, Zones 1 & 2, Groups llB, llAClass II, Div. 1 & 2, Groups E,F,GClass IIINEMA 7(C,D) 9(E,F,G)
XEDS XDS-2003
NOTE: Space for additional drill & tap conduit opening1-1/4" for XEDS-302" for XEDS-60+100Also is location for SU3 drain and breather when requested.
SU3 Drain and brea ther
SU17 100 Amp sol id neut ra l
SU18 225 Amp sol id neut ra l
SU40 Lock “on” for handle
KIT-251 100 Amp ground lug
KIT-252 225 Amp ground lug
NOTE: A & B dimensions are for mounting.
SWITCHAMPERES
30
60
100
200