  • Copyright DeclarationThe copyright of this manual belongs to SolaX Power Co., Ltd. . Any corporation or individual should not plagiarize, partially copy or fully copy it (including software, etc.), and no reproduction or distribution of it in any form or by any means. All rights reserved.SolaX Power Co., Ltd. reserves the right of final interpretation. This information is subject to changes without notice.

    www.solaxpower.com

    X-Hybrid SeriesUser Manual

  • Contents

    01

    1 NOTES ON THIS MANUAL

    1.1 SCOPE OF VALIDITY1.2 TARGET GROUP1.3 SYMBOLS USED

    ............................................................................................

    ...................................................................................................

    ...................................................................................................

    ................................................................................... 03030303

    2 SAFETY

    2.1 APPROPRIATE USAGE2.2 IMPORTANT SAFETY INSTRUCTIONS2.3 EXPLANATION OF SYMBOLS2.4 EC DIRECTIVES

    ..........................................................................................................................

    .........................................................................................

    ...............................................................

    .............................................................................

    .....................................................................................................

    0404050609

    3 INTRODUCTION

    3.1 BASIC FEATURE AND DIFFERENT WORKING MODES3.2 TERMINALS OF X-HYBRID READY INVERTER, HYBRID INVERTER AND BMU3.3 DIMENSION3.4 IDENTIFICATION OF X-HYBRID

    ........................................................................................................

    ....................................

    .........................................................................................................

    ........................................................................

    1010101213

    4 TECHNICAL DATA FOR X-HYBRID INVERTER

    4 .1 DC INPUT4.2 AC OUTPUT4.3 EPS OUTPUT WITH INTERNAL CHARGER(E VERSION FOR SK-SU)4.4 EFFICIENCY, SAFETY AND PROTECTION4.5 INTERNAL CHARGER (FOR SK-SU)4.6 GENERAL DATA

    ...............................................

    .............................................................................................................

    ................

    .........................................................

    ........................................................................

    ..........................................................................................................

    13131414151516

    6 INSTALLATION

    6.1 UN PACKING6.2 CHECK FOR TRANSPORT DAMAGE6.3 INSTALLATION PRECAUTION6.4 PREPARATION6.5 INSTALLATION STEPS6.6 CONNECTIONS OF X-HYBRID SYSTEM 6.6.1 THE MAIN STEPS TO CONNECT THE X-HYBRID SYSTEM

    ............................................................................................................

    ........................................................................................................

    ............................................................................

    ......................................................................................................

    .........................................................................................

    ..................................................................

    .............................................................

    .......................

    1717191921222323

    .....................................................................................................

    5 TECHNICAL DATA FOR X-HYBRID BMU 5 .1 ELECTRICAL DATA

    5 .2 GENERAL DATA..............................................................................................

    ....................................................................................................

    13

    16...........................................................1617

    Contents

  • 02

    8 TROUBLESHOOTING 8.1 TROUBLE SHOOTING8.2 ROUTINE MAINTENANCE

    ...........................................................................................

    .........................................................................................

    ..................................................................................

    9 DECOMMISSIONING 9.1 DISMANTLING THE INVERTER9.2 PACKAGING9.3 STORAGE9.4 DISPOSAL

    ..........................................................................................

    ..........................................................................

    ..............................................................................................................

    .............................................................................................................

    .........................................................................................................

    7 OPERATION METHOD

    6.6.2 COMMUNICATION INTERFACE

    ........................................................................................

    .............................................................

    48 4852

    53 53535353

    36

    363738

    6.7 INVERTER MANIPULATION3435

    7.1 CONTROL PANEL7.2 LCD FUNCTION7.3 LCD OPERATION

    ..................................................................................................

    ...................................................................................................

    ....................................................................................................

    Contents

  • 1.1 Scope of Validity

    This manual is an integral part of inverter, and it describes the assembly, installation, commissioning, maintenance and failure search of the below inverters. Please read it carefully before operating.

    1 Notes on This Manual

    1.2 Target GroupThis manual is for qualified electricians. The tasks described in this manual onlycan be performed by qualified electricians.

    1.3 Symbols Used

    The following types of safety instructions and general information appear in thisdocument as described below:

    The X-hybrid has E version and C version. The C version is provided with suffixCand is mainly for city solution,without EPSfunction.All model number of the C version inverter will be provided with suffixC.The E version is mainly for country solution ,with EPS function.Store this manual where it will be accessible at all times.

    SK-TL3000 SK-TL3700 SK-TL5000 SK-SU3000 SK-SU3700 SK-SU5000 SK-BMU1300

    Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.

    DANGER !

    Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury.

    WARNING!

    Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

    CAUTION!

    Note provides tips that are valuable for the optimal operation of your product.

    NOTE!

    Notes on this Manual

    03

    SK-BMU2500 SK-BMU5000

  • 2 Safety

    Safety

    04

    2.1 Appropriate Usage The X-hybrid includes :- Hybrid ready inverter SK-TL which can convert the DC current of the PV generator into AC current for on grid or off grid usage. - Hybrid inverter SK-SU, which can store the energy in the battery for self-use and also can convert the DC current of the PV generator into AC current for on grid or off grid usage.- Hybrid battery management unit (BMU), which can work together with the SK-TL to implement a battery storage system.- X-hybrid E version with EPS can supply the energy from battery and PV generator when the grid is lost.

    Note: For SK-TL series , the fuse and battery are not used The CT can be replaced with meter if necessary. The EPS function is only for E version

    X-Hybrid inverter(E version)

    Load

    Current sensor

    Electricalgrid

    PV array

    AC distribution box

    *Fuse

    *Battery

    Surge arrestorFuse

    AC Breaker

    DC distribution box

    Surge arrestorFuse

    DC Breaker

    Electric meter,bidirectional

    Grid EPS

    EPS contactor

    EPSLoad

    L line

    CT

    Public Grid

    Breaker

  • Induced surges are the more likely cause of lighting damage in majority or installations,especially in rural areas where electricity is usually by long overhead lines. Surgemay be included on both the PV array conduction and the a.c. cables leading tothe building.

    Specialists in lighting protection should be consulted during the end use application.Using appropriate external lighting protection, the effect of a direct lightningstrike into a building can be mitigated in a controlled way, and the lightningcurrent can be discharged into the ground.

    Installation of SPDs to protect the inverter against mechanical damage andexcessive stress include a surge arrester in case of a building with externallightning protection system (LPS) when separation distance is k ept.

    To protect the d.c. system, surge suppression device (SPD type2) should be fittedat the inverter end of the d.c cabling and at the array, located between theinverter and the PV generator, if the voltage protection level ( VP) of the surgearresters is greater than 1100V, a additional SPD type 3 required for surge protectionfor electrical devices.

    To protect the a.c system, surge suppr