conny andersson standards standards iec 60118-4 sound examples [email protected]

21
www.univox.eu Hearing Loop System Conny Andersson Standards IEC 60118-4 Sound examples [email protected]

Upload: drusilla-boyd

Post on 15-Jan-2016

222 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Hearing Loop System

Conny Andersson

Standards IEC 60118-4

Sound examples

[email protected]

Page 2: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Hearing InstrumentReverberation time = 2 secSpeaker @ 4m distanceBabble noise (other speakers)Output from a Hearing Aid (artificial ear)

Page 3: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

International Standards, IEC

Harmonized world wide

Hearing Instrument (HI)

Hearing Loop system

InternationalElectrotechnicalCommission

American NationalStandard Institute

Page 4: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

IEC 60118-4, “Loop Standard”

Magnetic Field Strength = 400mA/m.

Relates directly to the output level of the Hearing Instrument

Coverage area/space (sitting and standing), +-3dB

Page 5: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Field distribution – level/coverage

Level: 400mA/m

Fluctuation: within +-3dB

Page 6: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Field distribution – level/coverage

(This slide contains the notes for the previous slide)

Page 7: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Frequency response

High frequency damping or metal loss is increased as a function of the distance to the loop wire. It cannot be fully compensated by the loop amplifier.

It can be compensated by the loop figuration.

Page 8: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

No frequency limitations

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

Page 9: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

High frequency loss from 1kHz

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

Page 10: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

High frequency loss from 500Hz

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

Page 11: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

No frequency limitations

9 seconds

100 200 300 500 1k 2k 3k 5k Hz

Page 12: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Surrounding noise (hum)

Background noise (hum) from electrical appliances creates noise directly into the Hearing Instrument

Standard: less than -32dBA (-47dBA)

Level, Magnetic Field Strength 400mA/m

Page 13: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Background Noise (hum)High background noise: -12dBATiresome

Page 14: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Adding a weak amplifier Low Field Strength: -12dB (100mA/m)Very low speech intelligibility

Page 15: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Stronger amplifier – same noiseAccepted Field Strength: 0dB (400mA/m)Enhanced speech intelligibility

Page 16: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Approved field strength– same noiseAccepted Field Strength: +3dB (560mA/m)Further enhanced speech intelligibility

Page 17: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Complies to standardCorrect Field Strength: 0dB (400mA/m)Noise complies to the standard, -32dBA

Page 18: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

High quality Loop SystemHigh Field Strength: +3dB (560mA/m)Noise complies to -47dBA

Page 19: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Conclusions of sound examples

Systems that sounds “noisy” is often a reflection of a weak hearing loop amplifier.

Loop systems could often easily be updated to comply with the level requirements (with increased Signal to Noise ratio and speech intelligibility).

Page 20: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Conclusion and adviseFollow the international standard

Do not trust the manufacturers coverage area as they are highly overstated for practical installations. Trust real measurements.

A hearing instrument cannot be used to certify a hearing loop system.

Page 21: Conny Andersson Standards Standards IEC 60118-4 Sound examples Conny.Andersson@edin.se

www.univox.eu

Thank you for your attention!

[email protected]