www.aten.comInformation may be privileged 2
• Since 1979
• “Simply better solution”, strive for continuous innovation
• Business in China, Japan, Korea, Canada, UK and USA
• Sales volume of KVM - No. 1 in the world
ALTUSEN Power Over the NET™ SolutionALTUSEN Power Over the NET™ Solution
4
AgendaAgenda
• ALTUSEN Power Over the NET™ Solutions
• Case Studies & Successful Story
• Competitors Overview
5
IT Professional’s ChallengesIT Professional’s Challenges
• What’s the load of each power circuit?
• What’s the power usage of each device?
• Will power circuit overloaded when installing a new device?
• Do you know which rack to install device?
• Can I control my power supply anytime at any place?
• When will you be notified a power circuit overloaded?
• How and how fast will you get the alarm information?
• What can you do when remote site’s device is crashed?
• Prevention of unauthorized server installation
Intelligent PDU – the solution to meet these Intelligent PDU – the solution to meet these challenges!challenges!
Data Center Planning Maintenance Flexibility
6
Why Power Over the NET™ Why Power Over the NET™
Gartner’s 10 Technology Trends to Watch
Source: Technology Trends You Can’t Afford to Ignore, December, 2009, Gartner
7
Why Power Over the NET™Why Power Over the NET™
Source: Technology Trends You Can’t Afford to Ignore, December, 2009, Gartner
8
• offers secure remote power control and monitor of IT devices
• Unique Safe Shutdown feature for safely shutdown Windows server before power off
• Centralized control by CC2000
Power Over the NET™ - PDUPower Over the NET™ - PDU
Facilitate power consumption monitoring to achieve
energy-saving and green IT
9
Power Over the NET™ - PDUPower Over the NET™ - PDU
PN5/7 series is designed to• Improve server rack usage (0U Mechanical Housing)• Enhance power consumption monitoring• Ensure safety power usage• Increase IT personnel efficiency and productivity• Increase server usage efficiency• Increase security• Reduce IP address usage
10
Top 5 PN5 Competitive AdvantagesTop 5 PN5 Competitive Advantages
• Real time PDU level measurement and power switch capability via network
• Various boot up and safe shutdown capability for proper server operation system shutdown
• Daisy chain capability (16 levels) for saving IP addresses and delivering redundant power mgmt capability
• Comprehensive event notification mechanism for real time reaction to critical events
• Integrated management via CC2000, API and KN/KM devices
11
PN 7 & PN 5 Series DifferencesPN 7 & PN 5 Series Differences
PN 7 series has the following additional features:
1) Per Outlet Power Measurement
2) Sensor Monitoring (temperature & humidity)
3) Digital Output Port (for DC devices like buzzer, alarm, SMS sender)
4) Modem Connection (OOBC)
12
Power Over the NET™ - PDU ModelsPower Over the NET™ - PDU Models
PN5212/PN5320/PN7212/PN7320
13
Power Over the NET™ - Model NumbersPower Over the NET™ - Model Numbers
PN 7 3 2 0
PN 7 2 1 2
PN 5 3 2 0
PN 5 2 1 2
Series Number – PN7 or PN5 series
Current (PDU) – IEC 32A or 16A
NEMA 30A or 20A
Outlet Port Number
20 ports or 12 ports
14
Connection Diagram – PN5320/PN7320Connection Diagram – PN5320/PN7320
15
PN5xxx/PN7xxx Hardware DifferencesPN5xxx/PN7xxx Hardware Differences
PN7xxx Hardware Interface
PN5xxx Hardware Interface
Push Button(For selection of display status)
Sensor ports
RJ11 ConnectorDC Output
Terminal Block
LED light(PDU status and selected display parameters)
And Per Outlet Power Measurement
• Per Outlet Power Measurement• Support Modem• Support DC Output• Temperature/Humidity Sensor
16
PN5/PN7 DifferencesPN5/PN7 Differences
17
PN Series Main FeaturesPN Series Main Features
- Outlet Level Monitoring (PN7xxx)
- IEC & NEMA Standard Models
- Sensor Monitoring – temperature & humidity (PN7xxx)- Digital Output Port (PN7xxx)
- Modem Connection (PN7xxx) – Dial-in, Dial-back, Dial-out
- Multiple Power Control Methods
- Safe Shutdown support for Windows system
18
PN Series Main FeaturesPN Series Main Features
- Third-party Authentication Support
- Daisy Chain Provisioning
- IPV6 Support.
- Encryption: SSL128 bit (browser access)
- Advanced Account Policy
- Real Time Protection and Alert.
- IP / MAC Filter
19
PN Series Main FeaturesPN Series Main Features
- Outlet Group support (single PDU or cross PDU)
- On/Off Scheduling (daily, weekly, monthly, user-specified)
- Log Server AP(ATEN) & Syslog (Microsoft)
Management ConsoleManagement Console
20
Outlet Icon TypesOutlet Icon Types
21
1. Steady Amber :
Power to the outlet is On.
2. Flashing Amber :
A change in the outlet's power status is pending
3. Steady Gray:
Power to the outlet is Off.
4. Flashing Gray:
Power to the outlet is Off, but Wake On LAN has been specified as the remote power option
5.Flashing Light bulb :
The outlet exceeds at least one of the minimum or maximum threshold values that were set for it
22
Applications – Remote Data CenterApplications – Remote Data Center
23
Connection Diagram - PN5/PN7 SeriesConnection Diagram - PN5/PN7 Series
24
Applications - Multiple Access Applications - Multiple Access
25
Multiple Access User Interface and Text MenuMultiple Access User Interface and Text Menu
26
Applications – Flexible Usage / SetupApplications – Flexible Usage / Setup
27
CC2000 & KVM Devices Central Management CC2000 & KVM Devices Central Management
28
At a GlanceAt a Glance
29
Power Over the NET™Power Over the NET™
PN9108 8-Port Power Over the NET™ Offers Secure Remote Power Control and Monitor of IT Devices• Remotely power on/off/reboot each outlet via TCP/IP and a built-in 10/100 Ethernet port
– or control locally via RS-232 port• Daisy chain up to 15 additional stations and control up to 128 outlets• Access via secure browser, Telnet and local Console• Cumulative current measurement and monitoring of PDU power load• Configurable outlet sequencing prevents surge outages after power loss• Over current protection and recovery for each outlet• Scheduling power outlet On/Off• Safe shutdown and rebooting for Windows systems• Port grouping enables – perform the same action on grouped outlets• Event logging and log export• External modem support for OOBC management
30
Connection Diagram – PN9108Connection Diagram – PN9108
31
Power Over the NET™Power Over the NET™
PN0108 8-Port Power Over the NET™• Remote power on / off / reboot control for eight outlets via Over the NET™ KVM
switches, or KVM on the NET™ through built-in RS-232 PON port• Daisy-chain up to 15 additional stations to control up to 128 outlets• Over current protection and recovery for each outlet• Easy setup and operation via a GUI interface• Safe shutdown and rebooting for Windows systems• Port grouping enables – perform the same action on
grouped outlets
32
Connection Diagram – PN0108Connection Diagram – PN0108
33
Management Console – Status & Control Management Console – Status & Control
34
Management Console - Device MonitorManagement Console - Device Monitor
35
At a GlanceAt a Glance
36
37
Case Study- Telecommunication Case Study- Telecommunication
Competitor – Avocent PM PDUCompetitor – Avocent PM PDU
38
Competitor – Avocent PM PDUCompetitor – Avocent PM PDU
• Features and Benefits
• Outlet-Level, Phase-Level and Strip-Level Current/Voltage/Power Metering with Threshold/Alert Capabilities
• Capability to Remotely Switch Outlets Through On-Board Web Interface, DSView 3 Management Software ( available on PM 3000 only)
• On-Board Web Interface
• IP and Serial Interface Options
• Daisy Chaining - up to five PDUs or a maximum of 128 outlets
• Integration with DSView 3 Management Software
• Integration with DSView 3 Software Power Manager Plug-In
- For historical reporting across multiple PDUs
• Electronic Overcurrent Protection
• Sequential Startup
• Internal Temperature Sensor and Two Optional External Sensors
39
40
Competitor – Raritan PX Competitor – Raritan PX
41
42
IEC Standard ModelsIEC Standard Models
43
NEMA Standard ModelsNEMA Standard Models
44
Multiple Power Control MethodsMultiple Power Control Methods
45
Safe ShutdownSafe Shutdown
Conditions for Safe Shutdown:
- Windows 98 or higher
- “Power Monitor Utility” installed
- MAC address of the computer filled in the “OUTLET LEVEL CONFIGURATION PAGE”
TCP/IP
Power monitor utility
OnOff
46
PDU & Outlet Level MonitoringPDU & Outlet Level Monitoring
Measure power consumption at PDU/Outlet– Current (A)– Voltage (V)– Power (W)– Power dissipation (KWH)
Local
PDU/Outlet power parameters local display
Station ID and outlet Display readings in 2 digit LED
Cross-level
Remote
47
Sensor MonitoringSensor Monitoring
• Supports Temperature and Humidity Sensor Monitoring.• Available Sensors:
a)EA1140: Temperature Sensor
b)EA1240 : Temperature and Humidity Sensor
48
Digital Output PortDigital Output Port
49
OOBC - Dial-in modeOOBC - Dial-in mode
Modem
Modem
PSTN
Dial in to connect PN7xxx series
PN7xxx
50
OOBC – Dail-back modeOOBC – Dail-back mode
Modem
Modem
PSTN
Hang up the phone
Fixed number Dial back
PN7xxx
51
OOBC – Dail-out modeOOBC – Dail-out mode
52
Real-time Protection and AlertReal-time Protection and Alert
• PDU level over-current protection • Following Alerts are issued when
threshold is exceeded:
- Current - Voltage - Power
- Power Dissipation - Temperature
- Humidity
• Supported Alerts:
- Beeper and LED blinking (local)
- Web UI display
- Digital Output
- SNMP Trap
- Email (SMTP)
- Syslog / ATEN Log server
53
IPV6 Address FormatIPV6 Address Format
• IPV6 Configuration
`
Note: Specifying the Alternate DNS server address is optional.
54
Daisy Chain To PN7212/PN7320Daisy Chain To PN7212/PN7320
55
Third-party AuthenticationThird-party Authentication
TCP/IP
PN5xxx / PN7xxx
TACACS LDAP(S)
Active Directory
RADIUS
Username
Password
56
Advanced Account PolicyAdvanced Account Policy
57
Outlet GroupOutlet Group
58
On/Off SchedulingOn/Off Scheduling
59
IP / MAC FilterIP / MAC Filter
60
PDU Product DifferentiationPDU Product Differentiation