WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected] ® JUNCTION BOX MOUNT FOR CONDUIT For use on applications where conduit wiring is needed. 1. Loosen (4) Lens Screws and swing open Hinged Door. Screws will remain in place with O-Rings. 2. Loosen and remove (2) Housing Screws. Remove Housing from Back Box. Keep Housing Gasket intact for re-assembly. 3. Feed wires into Back Box through Silicone Wiring Plug, if not using conduit/ connectors. 4. Secure Back Box to the mounting surface using hardware appropriate for that mounting surface. Silicone around the edge of Back Box Gasket (self adhesive) and/ or junction box. 5. Wire the fixture using UL listed wire connectors according to NEC and local codes. Apply sealant to all unused conduit entry points. 6. Place Gasket between Back Box and Housing. Re-mount Housing to Back Box. Check Housing Gasket seal all around the Back Box. 7. Re-mount Door to Housing. Tighten (4) Lens Screws. Check door gasket (not shown) seal. 8. Fixture is UL Listed for down and up lighting and may be mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position. Lens Screws Junction Box Surface Mount Back Box Housing Gasket Housing Hinged Door Housing Screws SURFACE MOUNT FOR RECESSED JUNCTION BOX For use with recessed junction box and wiring. 1. Mount Surface Plate to fixture with (4) Surface Plate Screws. There are two screws from the front and two screws from the back. Make sure Housing Gasket makes complete seal all the way around. 2. Use supplied crossbar. Mount Crossbar to recessed junction box with (2) screws. 3. Place Junction Box Gasket on back of the fixture. Gasket should create seal against mounting surface. 4. Wire fixture to supply wires in recessed junction box according to wiring section. 5. Use 1/4 x 20 stainless steel Mounting Screw to attach fixture to Crossbar. Tighten Mounting Screw. 6. Cover screw with Cap, provided. 7. Fixture is UL Listed for down and up lighting and may be mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position. Crossbar Junction Box Gasket Mounting Screw Cap Recessed Junction Box (not provided) Surface Plate Housing Gasket (4) Surface Plate Screws IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the Back Box and/or Junction Box. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries. Back Box Gasket Silicone Wiring Plug

Upload: others

Post on 11-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

WPLED 26W INSTALLATION INSTRUCTIONSThank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

JUNCTION BOX MOUNT FOR CONDUITFor use on applications where conduit wiring is needed.1. Loosen (4) Lens Screws and swing open Hinged Door.

Screws will remain in place with O-Rings.2. Loosen and remove (2) Housing Screws. Remove Housing

from Back Box. Keep Housing Gasket intact for re-assembly.3. Feed wires into Back Box through Silicone Wiring Plug, if

not using conduit/ connectors.4. Secure Back Box to the mounting surface using hardware

appropriate for that mounting surface. Silicone around the edge of Back Box Gasket (self adhesive) and/ or junction box.

5. Wire the fixture using UL listed wire connectors according to NEC and local codes. Apply sealant to all unused conduit entry points.

6. Place Gasket between Back Box and Housing. Re-mount Housing to Back Box. Check Housing Gasket seal all around the Back Box.

7. Re-mount Door to Housing. Tighten (4) Lens Screws. Check door gasket (not shown) seal.

8. Fixture is UL Listed for down and up lighting and may be mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position.

Lens Screws

Junction Box Surface Mount

Back Box Housing Gasket

Housing

Hinged Door

Housing Screws

SURFACE MOUNT FOR RECESSED JUNCTION BOXFor use with recessed junction box and wiring.1. Mount Surface Plate to fixture with (4) Surface Plate

Screws. There are two screws from the front and two screws from the back. Make sure Housing Gasket makes complete seal all the way around.

2. Use supplied crossbar. Mount Crossbar to recessed junction box with (2) screws.

3. Place Junction Box Gasket on back of the fixture. Gasket should create seal against mounting surface.

4. Wire fixture to supply wires in recessed junction box according to wiring section.

5. Use 1/4 x 20 stainless steel Mounting Screw to attach fixture to Crossbar. Tighten Mounting Screw.

6. Cover screw with Cap, provided.7. Fixture is UL Listed for down and up lighting and may be

mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position.

Crossbar

Junction Box Gasket

Mounting Screw

Cap

Recessed Junction Box (not provided)

Surface Plate

Housing Gasket

(4) Surface Plate Screws

IMPORTANTREAD CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the Back Box and/or JunctionBox. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.

Door

Back Box Gasket

Silicone Wiring Plug

Page 2: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

WPLED 26W INSTALLATION INSTRUCTIONSThank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

TROUBLESHOOTING 1. Check that the line voltage at fixture is correct. Refer to

wiring directions.2. Is the fixture is grounded properly?3. Be sure the photocell, if used, is functioning properly.

CLEANING & MAINTENANCECAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.1. Clean glass lens with non-abrasive glass cleaning

solution.2. Do not open fixture to clean the LED. Do not touch the

LED.

ON-OFF WIRINGUniversal voltage driver permits operation at 100V to 277VAC, 50 or 60Hz except fixtures factory ordered with a 120V photocell (/PC) and 277V photocell (/PC2). For Non-Dimming, follow the wiring directions as in fig. 1.1. For Junction Box Mount, feed wires through silicone

wiring plug into the junction box.2. Connect the black fixture lead to the (+) LINE supply lead.3. Connect the white fixture lead to the (-) COMMON supply

lead.4. Connect the bare copper Ground wire from fixture to

supply ground.

JUNCTION BOX 1. The Junction box has (4) conduit entry points on the

center of each side and (1) in the center back.2. Mounting Points are dimensioned below.

PATENTS: US: pat. D634,878, CN: ZL201030679778.2

4 3/4”

2 3/16”

3 1/2”

1 1/8”

1 1/8”

Mounting Points

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Fig. 2

0-10V DIMMABLE WIRINGUniversal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming, follow the wiring directions as in fig. 2.1. For Junction Box Mount, feed wires through silicone

wiring plug into the junction box.2. Connect the black fixture lead to the (+) LINE supply lead.3. Connect the white fixture lead to the (-) COMMON supply

lead.4. Connect the GROUND wire from fixture to supply ground.

Do NOT connect the GROUND of the dimming fixture to the output.

5. Connect the purple fixture lead to the (V+) DIM lead.6. Connect the gray fixture lead to the (V-) DIM lead.7. Cap the yellow fixture lead, if present. Do NOT connect.

LIGHTFIXTURE

(+)LINE BLACK

(-)COMMON WHITE

GROUND GROUND

Fig. 1

WPLED26-IN 1213

Easy Installation & Product HelpTech Help LineCall our experts 888 RAB-1000

©2013 RAB LIGHTING Inc.Northvale, New Jersey 07647 USA

rabweb.comVisit our website for product info

emailAnswered promptly [email protected]

Page 3: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

WPLED 18W-26W WITH EMERGENCY BATTERYINSTALLATION INSTRUCTIONS

®

IMPORTANTREAD CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the Back Box and/or JunctionBox. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.

Door

MOUNTINGCAUTION: Suitable for Wet Locations as Downlight and Wall Mount only.

1. Loosen and remove (4) Screws and separate Back Box from Emergency Housing. Use provided tether.

2. Drill necessary holes on Back Box. Measurements of drill positions are shown below.

3. Match the hole pattern and place the Gasket on the Back Box.

4. Secure the Back Box on the surface with hardware appropriate for the mounting surface.

5. Wire the fixture to the incoming supply wires according to NEC and local codes. Use UL listed wire connectors.

6. For WPLED*/E and WPLED*/EC wiring details refer to the appropriate Wiring Diagram section supplied Instruction Sheet.

7. Connect the battery connectors. DO NOT connect the Batteries before wiring the fixture to the supply.

8. Secure Housing to Back Box. Check Housing Gasket seal all around.

9. Apply sealant to all unused conduit entry points.To ensure weatherproof seal, apply weatherproof silicone sealant around the edge where the fixture meets the wall.

Housing

Screws

Two connectors for WPLED18/EC OR WPLED26/EC

Back Box Housing Gasket

Gasket

Screws

Page 4: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

WPLED 18W-26W WITH EMERGENCY BATTERYINSTALLATION INSTRUCTIONS

®

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

WPLED18-26/E2-IN 0517

Easy Answersrabweb.comVisit our website for product info

Tech Help LineCall our experts - 888 722-1000

e-mailAnswered promptly - [email protected]

Free Lighting LayoutsAnswered online or by request© 2017 RAB LIGHTING Inc.

Northvale, New Jersey 07647 USA

CLEANING & MAINTENANCE CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is ener-gized.

1. Clean glass lens & fixture with non-abrasive glass cleaning solution.

2. Do not open fixture to clean the LED. Do not touch the LED.

2.940[74,68]

7.500[190,5]

.600[15,24]

3.750[95,25]

DRILL TEMPLATE

7.5”3.75”

0.6”

2.94”

EMERGENCY BATTERY WIRING CAUTION: THIS IS AN EMERGENCY BATTERY BACKUP FIXTURE. Voltage could be present in Battery. To prevent high voltage from being present on output leads, inverter connector must be open. Do not join inverter connector until installation is complete and AC power is supplied to the emergency ballast. NOTE: Make sure that the necessary branch circuit wiring is available. An unswitched AC source of power is required. The emergency ballast must be fed from the same branch circuit as the AC ballast.Do not use any supply voltage other than those specified below. WPLED18 OR WPLED26 120V-277V, 50/60Hz1. Connect the UNSWITCHED black fixture lead to the HOT

supply lead.2. Connect switched and unswitched black leads together, if

not using a switching method.3. If switching, connect SWITCHED black lead to a switch.4. Connect the COMMON fixture lead to the COMMON

supply lead.5. For 0-10V Dimming, connect DIM (+) purple lead and DIM

(-) gray lead to 0-10V dimmer. 6. Connect the GROUND wire from fixture to supply ground.

Do NOT connect the GROUND of the dimming to the output.

7. All unused leads must be capped and insulated.8. After installation is complete, supply AC power to the

emergency ballast and join the inverter connector.9. At this point, power should be connected to both the

AC ballast and the emergency ballast, and the Charging Indicator Light should illuminate indicating the battery is charging.

10. A short-term discharge test may be conducted after the emergency ballast has been charging for one hour. Charge for 24 hours before conducting a long-term discharge test. Refer to OPERATION.

US: Pat. D643,147; CN: ZL201130171304.1; MX: 39260; TW: D159371; CA: D Patent Pending.

Page 5: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

RE

D

BLA

CK EM

RG

ENC

Y D

RIV

ER

TEST

SW

ITC

H

IF U

NSW

ITC

HED

,C

AP

TWO

BLA

CK

WIR

ES T

OG

ETH

ER

EM

ERG

ENC

Y BA

TTER

Y

Cus

tom

er s

houl

d co

nnec

t uni

t con

nect

or o

nly

afte

rfin

ishi

ng w

iring

to A

C p

ower

. Bat

tery

cou

ld h

ave

char

ge a

nd s

hock

.

INV

ERTE

RC

ON

NEC

TOR

:C

ON

NEC

TO

NLY

AFT

ERA

C S

UP

PLY

PO

WER

IS

CO

NN

ECTE

DR

AB

LA

BEL

- A

DD

LED

DR

IVER

WP

LED

18/E

and

WP

LED

26/E

WIR

ING

DIA

GR

AM

(Ref

er to

nex

t pag

e fo

r WPL

ED*/E

C w

iring

dia

gram

)

WPL

ED26

/E2-

IN 0

517

Page 6: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

AC

DRIV

ER

COM

GRO

UND

EMER

GEN

CY

D

RIVE

R

BATT

ERY

1

LEAV

E O

PEN

DO N

OT

CONN

ECT

DURI

NGM

ANUF

ACTU

RING

CUST

OM

ER S

HOUL

DCO

NNEC

T O

NLY

AFTE

RFI

NISH

ING

WIR

ING

TO

AC

POW

ER.

BATT

ERY

COUL

DHA

VE C

HARG

E &

SHO

CK

RED-

WHI

TE S

TRIP

E

RED

FUSE

HOLD

ER

CHAR

GIN

GIN

DICA

TOR

LIG

HT /

TEST

SW

ITCH

BLUE

WHI

TE

YELL

OW

YELL

OW

- BL

ACK

STRI

PE

WPL

ED26

UNSW

ITCH

ED H

OT

CHAR

GIN

GIN

DICA

TOR/

TEST

SWIT

CHBL

ACK

WHI

TE

WHI

TE/B

LACK

VIO

LET

BRO

WN

BLAC

KRED-

WHI

TE S

TRIP

E

BLUE

BLAC

K

BLAC

KG

REY

GRE

Y

WHI

TE

YELL

OW

/RED

WHI

TE -

RED

STRI

PE

WHI

TE

BLAC

K

WHI

TE

BLAC

K

BLAC

K

BLAC

K

BLAC

K

SWIT

CHED

HO

TRA

B LA

BEL

- ADD

RAB

LABE

L - A

DD

LABE

L PR

OVI

DED

BATT

ERY

2

EMER

GEN

CYHO

USIN

G

REDRE

D

RED

RED

BLUE

/ORA

NGE

RED

BLAC

K

WHI

TE

RED

YELL

OW

/RED

RED

WHI

TE

WHI

TE

WHI

TE

YELL

OW

/RED

RED

BLUE

BLUE

RED

WHI

TE

RED

YELL

OW

/RED

RED

WHI

TE

WHI

TE

BLUE

/ORA

NGE

BAT

1

BAT

1

BAT

2

BAT

2

BAT

1

BAT

1

BAT

2

BAT

2

WP

LED

18/E

C O

R W

PLE

D26

/EC

WIR

ING

DIA

GR

AM

(Ref

er to

pre

viou

s pa

ge fo

r WPL

ED*/E

wiri

ng d

iagr

am)

WPL

ED26

/E2-

IN 0

517

Page 7: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

RED

BLAC

K EMER

GENC

Y DR

IVER

TEST

SW

ITCH

EMER

GENC

Y BA

TTER

Y

Custo

mer

shou

ld co

nnec

t unit

conn

ecto

r only

afte

rfin

ishing

wirin

g to

AC

powe

r. Ba

ttery

could

hav

ech

arge

and

shoc

k.

INVE

RTER

CON

NEC

TOR:

CON

NEC

TO

NLY

AFT

ERAC

SUP

PLY

POW

ER I

SCO

NN

ECTE

DRA

B LA

BEL

- AD

D

PC

D

RIVE

R

WP

LED

18/E

C O

R W

PLE

D26

/E W

ITH

PC

WIR

ING

DIA

GR

AM

(wiri

ng d

iagr

am)

Page 8: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

WPLED 26W DC INSTALLATION INSTRUCTIONSThank you for buying RAB lighting � xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

JUNCTION BOX MOUNT FOR CONDUITFor use on applications where conduit wiring is needed.1. Loosen (4) Lens Screws and swing open Hinged Door.

Screws will remain in place with O-Rings.2. Loosen and remove (2) Housing Screws. Remove Housing

from Back Box. Keep Housing Gasket intact for re-assembly.3. Feed wires into Back Box through Silicone Wiring Plug, if

not using conduit/ connectors.4. Secure Back Box to the mounting surface using hardware

appropriate for that mounting surface. Silicone around the edge of Back Box Gasket (self adhesive) and/ or junction box.

5. Wire the � xture using UL listed wire connectors according to NEC and local codes. Apply sealant to all unused conduit entry points.

6. Place Gasket between Back Box and Housing. Re-mount Housing to Back Box. Check Housing Gasket seal all around the Back Box.

7. Re-mount Door to Housing. Tighten (4) Lens Screws. Check door gasket (not shown) seal.

8. Fixture is UL Listed for down and up lighting and may be mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position.

Lens Screws

Junction Box Surface Mount

Back Box Housing Gasket

Housing

Hinged Door

Housing Screws

SURFACE MOUNT FOR RECESSED JUNCTION BOXFor use with recessed junction box and wiring.1. Mount Surface Plate to � xture with (4) Surface Plate

Screws. There are two screws from the front and two screws from the back. Make sure Housing Gasket makes complete seal all the way around.

2. Use supplied crossbar. Mount Crossbar to recessed junction box with (2) screws.

3. Place Junction Box Gasket on back of the � xture. Gasket should create seal against mounting surface.

4. Wire � xture to supply wires in recessed junction box according to wiring section.

5. Use 1/4 x 20 stainless steel Mounting Screw to attach � xture to Crossbar. Tighten Mounting Screw.

6. Cover screw with Cap, provided.7. Fixture is UL Listed for down and up lighting and may be

mounted in either position. Fixture may not melt heavy snow accumulation in an uplight position.

Crossbar

Junction Box Gasket

Mounting Screw

Cap

RecessedJunction Box(not provided)

Surface Plate

Housing Gasket

(4) Surface Plate Screws

IMPORTANTREAD CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining � xture. No user serviceable parts inside.

CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened � rmly. Apply weatherproof silicone sealant around the edge of the Back Box and/or JunctionBox. This is especially important with an uneven wall surface. Silicone all plugs and unused conduit entries.

Door

Back Box Gasket

Silicone Wiring Plug

Page 9: WPLED 26W INSTALLATION INSTRUCTIONS - RAB …...WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get

WPLED 26W DC INSTALLATION INSTRUCTIONSThank you for buying RAB lighting � xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments. Call the Marketing Department at 888-RAB-1000 or email: [email protected]

®

TROUBLESHOOTING 1. Check that the line voltage at � xture is correct. Refer to

wiring directions.2. Is the � xture is grounded properly?3. Be sure the photocell, if used, is functioning properly.

CLEANING & MAINTENANCECAUTION: Be sure � xture temperature is cool enough to touch. Do not clean or maintain while � xture is energized.1. Clean glass lens with non-abrasive glass cleaning

solution.2. Do not open � xture to clean the LED. Do not touch the

LED.

ON-OFF WIRINGUniversal DC voltage driver permits operation at 10VDC to 30VDC.1. For Junction Box Mount, feed wires through silicone

wiring plug into the junction box.2. Connect the WHITE � xture lead to the

(+) supply lead.

3. Connect the BLACK � xture lead to the (-) supply lead.

4. Connect the bare copper Ground wire from � xture to sup-ply ground.

JUNCTION BOX 1. The Junction box has (4) conduit entry points on the

center of each side and (1) in the center back.2. Mounting Points are dimensioned below.

PATENTS: US: pat. D634,878, CN: ZL201030679778.2

4 3/4”

2 3/16”

3 1/2”

1 1/8”

1 1/8”

Mounting Points

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

Fig. 1

WPLED26DC-IN 0914

Easy Installation & Product HelpTech Help LineCall our experts 888 RAB-1000

©2014 RAB LIGHTING Inc.Northvale, New Jersey 07647 USA

rabweb.comVisit our website for product info

emailAnswered promptly [email protected]

(+) (+) WHITE

(-) (-) BLACK