wiwynn achievements in ocp… · wiwynn achievements in ocp wiwynn solutions introduction min chao....
TRANSCRIPT
Wiwynn Achievements in OCPWiwynn Solutions Introduction
Min ChaoExecutive Director, SD2, Wiwynn
3-Year CAGR
>160 %
2018H12016 20172015
1BUSD
2014
2.8USD
2.8x2.8USD
Thriving Demand Leads to Fast Growth
Exponential Growth of Rack Integration
13Q2 …… 15Q3 15Q4 16Q1 16Q2 16Q3 16Q4 17Q1 17Q2 17Q3 17Q4 18Q1 18Q2
10KRacks
1KRacks
30kRacks
3 QUARTERS
6 QUARTERS
12 QUARTERS
20kRacks
1.5 Qs
OCP Solution Provider with 21 Accepted Products
4
Offering One-Stop Rack Integration Service
5
Tier1 CSPs Verification Deployed to >133 Hyperscale DCs
21” 19”
30,000+ RacksDelivered to >61 Global Locations
Computing PowerCPU Sockets & Memory
Storage CapacityHDDs and SSDs
I/O PerformanceIOPS & Throughput
Network Bandwidth
Resource Utilization
Power Consumption
WiRack – Workload Optimized Rack Solutions
2U3N Dual Socket Server
4U16N Single Socket Server
Computation Front-End U41
CN81~84
CN85~88
CN89~92
CN97~100
CN101~104
CN105~108
CN41~44
CN49-52
CN53~56
CN57~60
CN65~68
CN69~72
CN73~76
CN117~120
CN121~124
CN1~4
CN5~8
CN9~12
CN14~20
CN21~24
CN25~28
Power Shelf
Power Shelf
Blank PlateData Switch #2Data Switch #1
CN113~116
U26
U28
U30
U32
U34
U36
U6
U8
U10
U12
U18
U20
U22
U24
U38
U40
CN45~48
CN29~32
CN13~16U2
U4
U14
U16
CN33~36
CN37~40
CN125~128
CN109~112
CN93~96
CN77~80
CN61~64
U41
CN #08 CN #09
CN #04 CN #05 CN #06
CN #01 CN #02 CN #03
CN #16 CN #17 CN #18
CN #13 CN #14 CN #15
CN #22 CN #23 CN #24
CN #19 CN #20 CN #21
Switch #2Switch #1
CN #31 CN #32 CN #33
CN #28 CN #29 CN #30
CN #25 CN #26
CN #34 CN #35 CN #36Switch #4Switch #3
CN #40 CN #41 CN #42
CN #37 CN #38 CN #39
Power ShelfU10
U8
U6
U4
U2
CN #10 CN #11 CN #12
CN #07
U22
U20
U18
U16
U14
U12
U32
U30 Power ShelfU28
U26
U24CN #27
U40
U38
Blank Plate
CN #43 CN #44 CN #45
U36
U34
x4
x3
Two Typical Computing Configurations
8
Performance/Watt Optimized Dense Server
Two Typical Storage Configurations
9
Hot Storage Cold Storage
4U72Bay Storage JBOD
4U Storage Server
U41 Switch #1Blank Plate
U10
U30
U28
U26
U24
U22
U20
U40
U38
U36
U34
U32
Storage JBOD #6
Storage Server #3
Storage JBOD #5
Storage JBOD #4
Storage Server #1
Storage JBOD #1
Power Shelf
Storage JBOD #2
Storage JBOD #3
Storage Server #2
U8
U6
U4
U2
U18
U16
U14
U12
U41 Switch #1Blank Plate
U38Storage Server #8
U36
U34Storage Server #7
U32
U8Storage Server #2
U6
U4Storage Server #1
U2
U18
U16
Storage Server #3U14
U12
Power ShelfU10
Storage Server #4
U30 Power ShelfU28
Storage Server #6U26
U24
Storage Server #5U22
U20
U40
10
Density & Cooling Efficiency Optimized Storage Platform
Two Typical Configurations for AI Applications
4U8X GPU Server
Deep Learning AI Inference
2U3N 2 Socket Server
x3U41
Blank Plate
Compute Accelerator #1
CN #1 Blank CN #2
Blank Plate
Blank Plate
U8
U6
U4
U2
U26
U24CN #5 Blank CN #6
U22
U20
U18
U16
Compute Accelerator #2U14
U12
Power ShelfU10
Blank Plate
Switch #1Management Switch
CN #7 Blank CN #8
Compute Accelerator #4
Power Shelf
Compute Accelerator #3
U40
U38
U36
U34
U32
U30
U28
Blank Plate
CN #3 Blank CN #4
U41
Compute Accelerator #1
CN #3 Blank CN #4
CN #1 Blank CN #2
CN #15 Blank CN #16
CN #5 Blank CN #6
U36
Blank PlateU40
U38
U34
Power Shelf
Power Shelf
CN #9 Blank CN #10
CN #7 Blank CN #8
U4
U2
U12
U10
U8
U6
U22
U20
U18
U16
U14
U32
U30
U28
U26
U24
Switch #1Management Switch
CN #13 Blank CN #14
Compute Accelerator #4
Compute Accelerator #3
Compute Accelerator #2
CN #11 Blank CN #12
8x
2
GPU / FPGAPCIe3 x16 Slots
CPU-GPU Connection Modes. Balanced. Cascading GPU
The Best Server for AI / Deep Learning and HPC
112TFLOPS By Single-precision
floating-point
8SATA SSDs
WiRack21 Solutions Computation Front-End Hot
StorageCold
StorageDeep
LearningAI
Inference
2U3N Compute ServerProject Tioga Pass 45
Nodes
8Nodes
16Nodes
4U16N Compute ServerProject Yosemite V2
1288
Nodes
4U72Bay Storage ServerProject Bryce Canyon 8 3
4U72Bay Storage JBODProject Bryce Canyon 6
4U8G Compute Server 4 4
Wiwynn Cluster Manager
RSD PODM (Pod Manager)
RSD Enabled Hardware
Orchestrators & RSD-aware Workloads
Complement Physical Layer Management
Compute Accelerator Pool
NVMe SSD Pool
Compute Pool
iSCSI Services
Software DefinedNetwork
CPU
FW of BIOS & BMC Health Check & Diagnosis
FW of HBA & ExpanderTopology Mapping
FW of PCIe Switches & BMCTopology Mapping
15
Wiwynn Cluster Manager /RSD v2.3
16
How to Start?
Understand more aboutCluster Manager/RSD, OCP/Olympus, Edge
Build your ownenvironment
Fully utilize the powerof Cluster Manager/RSD, OCP/Olympus, Edge
Wiwynn on-sitePoC
@Wiwynn HQ in Taipei@FB Disaggregate Lab in Menlo Park@Wiwynn Manufacturing Site in Brno
WiRack21
SV7220G3
SV7000G2
ST7200
Network
Experience atWiwynnCertified Labs
• 3 server nodes• 1 JBOF, NVMe over PCIe/Fabrics• 1 storage server, iSCSI
Wiwynn Provides: Free License (Gold) Free Onsite PoC and Training
Try at your Lab, e.g.
No Hardware Cost Wiwynn Engineer Onsite Support PoC Closing Reports
Best TCO and Workload Optimized IT Solutions for Data Centers
• Wiwynn website:• Wiwynn Cluster Manager: http://www.wiwynn.com/english/product/type/details/34?ptype=40
• White Paper: http://www.wiwynn.com/usr_files/Wiwynn_CM_RSD2.1_Whitepaper.pdf
• Datasheet: http://www.wiwynn.com/usr_files/20171026104415_Datasheet%20-%20CM_171023.pdf
• Youtube: • https://www.youtube.com/watch?v=3jw5hEs3hoc&t=147s
• https://www.youtube.com/watch?v=o2OLPViUUFY
• https://www.youtube.com/watch?v=kce6AbLDm7A&t=1s
• https://www.youtube.com/watch?v=g8TDKqmZcnI
• Need Additional Information?• Technical support: [email protected]
• Follow us on Facebook / LinkedIn / Youtube
Learn More About Wiwynn Cluster Manager
18