wiring diagramsdms.hvacpartners.com/docs/1005/public/07/30hx-2w.pdf ·  · 2013-12-18wiring...

12
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. PC 903 Catalog No. 563-043 Printed in U.S.A. Form 30HX-2W Pg 1 4-00 Replaces: New Book 2 Tab 5c Wiring Diagrams DIAGRAM INDEX NOTE: For operating sequence, refer to Controls, Start-Up, Operation, Service, and Troubleshooting literature. POWER SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 1 500768 206-271 ALL 2 500914 CONTROL SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-271 24 3 500913 115,230 4 500778 206-271 24 5 500915 115,230 6 500916 COMPONENT ARRANGEMENTS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 7 500758 206-271 ALL 8 500917 30HXA, 30HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz

Upload: lykhue

Post on 03-May-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 903 Catalog No. 563-043 Printed in U.S.A. Form 30HX-2W Pg 1 4-00 Replaces: NewBook 2

Tab 5c

Wiring DiagramsDIAGRAM INDEX

NOTE: For operating sequence, refer to Controls, Start-Up, Operation, Service, and Troubleshooting literature.

POWER SCHEMATICS

Unit 30HXA,C Voltage Figure Number Label DiagramNo. 30HX

076-186 ALL 1 500768206-271 ALL 2 500914

CONTROL SCHEMATICS

Unit 30HXA,C Voltage Figure Number Label DiagramNo. 30HX

076-27124 3 500913

115,230 4 500778

206-27124 5 500915

115,230 6 500916

COMPONENT ARRANGEMENTS

Unit 30HXA,C Voltage Figure Number Label DiagramNo. 30HX

076-186 ALL 7 500758206-271 ALL 8 500917

30HXA, 30HXCCondenserless and

Fluid-Cooled Chillers50/60 Hz

Page 2: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

2

LEGEND

NOTES1. Three-phase motors protected against primary single phasing

conditions.2. Replacement of original wires must be with type 105° C wire or

its equivalent.3. Numbers on the right side of label diagrams indicate the line

location of applicable contacts. An underlined number signifiesnormally closed contacts; a plain number denotes normally opencontacts. Line numbers are shown on the left side of thediagrams.

4. Factory wiring is in accordance with National Electrical Code(NEC) U.S.A. Field modifications or additions must be in compli-ance with all applicable codes.

5. Wiring for main field power supply must be rated 75° C minimum.Use copper for all units. Maximum incoming wire size for eachterminal block is 500 kcmil.

6. Power for control circuit should be supplied from a separatesource (except 380/415 v units) through a field-supplied discon-nect with 30-amp maximum protection for 115-volt control circuitsand 15-amp maximum protection for 230-volt control circuit. Con-nect control circuit power to terminals 1 and 2 of TB4. Connect

neutral side of supply to terminal 2 of TB4. Control circuit conduc-tors for all units must be copper only. Control circuit power is fac-tory wired for 380/415-v units.

7. Terminals 13 and 14 of TB2 are for field external interlock con-nection for remote ON-OFF and terminals 11 and 12 of TB2 forCWP interlock and CWFS. The contacts must be rated for dry cir-cuit application capable of handling a 24 vac to 50 mA load.Remove jumper between 13 and 14 of TB2 if remote ON-OFF isinstalled.

8. Separate field-supplied 115-v or 230-v power circuits:Terminals 4 and 5 of TB2 are for control of chilled water pumpstarter.Terminals 2 and 3 of TB2 are for alarm.The maximum allowable load for each of these circuits is 125 vasealed.

9. Terminal 6 of TB2 is for condenser fan contactor B (HXA) or con-denser water pump (HXC). Terminal 1 of TB2 is for condenserfan contactor A (HXA). The maximum allowable load for each ofthese circuits is 125 va inrush, 125 va sealed. Separate fieldpower supply is not required.

ALM — AlarmC — Contactor, CompressorCB — Circuit BreakerCCN — Carrier Comfort NetworkCFC — Condenser Fan ContactorCD WP — Condenser Water PumpCOMM — CommunicationsCOMP — CompressorCPM — Compressor Protection ModuleCR — Control RelayCWP — Chilled Water PumpCWPI — Chilled Water Pump InterlockDGT — Discharge Gas ThermistorDPT — Discharge Pressure TransducerDSIO EXV — EXV DriverECWT — Entering Chilled Water Temp.EPT — Economizer Pressure TransducerEQUIP — EquipmentEXV — Electronic Expansion ValveFIOP — Factory-Installed OptionFU — FuseGND — GroundHPS — High-Pressure SwitchHSIO — Keyboard and Display ModuleHTR — HeaterLCWT — Leaving Chilled Water Temp.LDR — LoaderLL — Liquid LevelLS — Level SwitchMLC — Minimum Load ControlNEC — National Electrical Code (U.S.A.)OP — Oil PumpOPC — Oil Pump ContactorOPT — Oil Pressure TransducerPL — Plug Assembly

PRI — PrimaryPS — Power SupplyPSIO — Processor ModulePWR — PowerRBPL — Relay Board Plug AssemblyS — ShortingSEC — SecondarySN — Sensor (Toroid)SPT — Suction Pressure TransducerSW — SwitchT — ThermistorTB — Terminal BlockTEMP — TemperatureTRAN — TransformerXL — Across-the-Line Start1M — Wye2M — Delta

Terminal Block Connection

Marked Terminal

Unmarked Terminal

Unmarked Splice

Marked Wire

Marked Splice

Factory Wiring

Field Control WiringField Power WiringIndicates Common Potential Does Not Represent WiringAccessories or Options

Page 3: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig. 1 — Power Wiring, 30HXA,C076-186

Page 4: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig. 2 — Power Wiring, 30HXA,C206-271

Page 5: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig

. 3 —

Co

ntr

ol S

chem

atic

, 30H

XA

,C07

6-18

6; 2

4 V

Page 6: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig

. 4 —

Co

ntr

ol S

chem

atic

, 30H

XA

,C07

6-18

6; 1

15, 2

30 V

Page 7: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig

. 5 —

Co

ntr

ol S

chem

atic

, 30H

XA

,C20

6-27

1; 2

4 V

Page 8: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig

. 6 —

Co

ntr

ol S

chem

atic

, 30H

XA

,C20

6-27

1; 1

15, 2

30 V

Page 9: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig. 7 — Component Arrangement, 30HXA,C076-186

Page 10: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Fig. 8 — Control Arrangement, 30HXA,C206-271

Page 11: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label
Page 12: Wiring Diagramsdms.hvacpartners.com/docs/1005/Public/07/30HX-2W.pdf ·  · 2013-12-18Wiring Diagrams DIAGRAM INDEX NOTE: For operating ... Unit 30HXA,C Voltage Figure Number Label

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.PC 903 Catalog No. 563-043 Printed in U.S.A. Form 30HX-2W Pg 12 4-00 Replaces: NewBook 2

Tab 5c

Copyright 2000 Carrier Corporation