Solutions for Inbuild ing and tunnel applications
Project references
Product overview
Solutions for Building scenarios – DAS
- System design examples
- Product overview
Solutions for Tunnel scenarios
- System design examples
- Product overview
RADIAFLEX Selection Guideline RADIAFLEX Cables
CELLFLEX Cables
Combiners/Couplers/Splitters
Accessories
RFS: A leader in Wireless Indoor Solutions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 3/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 2
End-to-end supplier for
indoor coverage solutions
WINS serves as one-stop shop and
solutions provider for 2G, 3G, TETRA, and GSM-Rcoverage needs in complex environments
As one of the major players in the market place,
RFS has the portfolio, strength and size
to be and stay a long term partner.
Future proof roadmap Passive solutions WiMAX, Wifi, mobile TV,EV-DO, W-CDMA, HSPA & LTE ready
Global references, proven
track record
RFS: a reliable, experienced partner in
indoor solutions for more than 40 years
Reliable partner
Value Proposit ion Benefits
WINS delivers coverage solutions inside and throughout structures (tunnels, buildings, …)where coverage is not sufficient, not well managed, or for new constructions
RFS: A leader in Wireless Indoor Solutions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 4/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 3
The most RF broadband passive distributed antenna system (DAS)
• CELLFLEX and CELLFLEX LITE low loss feeder cables
• High performance RADIAFLEX radiating cables
• Broadband and ultra-broadband indoor antennas
• Broadband and ultra-broadband, low insertion loss, indoor passive RF
components (couplers, splitters)
380/6000MHz690/6400MHz 2400/5875MHz800/2700MHz
RFS: A leader in Wireless Indoor Solutions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 5/73
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 6/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 5
• Brazil, shopping malls, airports, 150+ sites
• Princess Hotel, Acapulco, Mexico
• CeBIT fair ground, Hannover, Germany
• Convention and Exhib. Centre, Hong Kong
• Shopping Centres, Hong Kong
• KOEX exhibition building, Seoul, Korea• Chek Lap Kok Airport, Hong Kong
• Marriott Hotel, Boston, USA
• Swiss Railways
• Jakarta, 60+buildings
• Road tunnel, Baltimore, USA
• Airport tunnels, Boston, USA
• Ted Williams Tunnel, Boston, USA
• Central Express Way CTE, Singapore
• Most road tunnels, Hong Kong• Harbour tunnel, Sydney, Australia
• Lefortovo tunnel, Moscow
• Italian Railways
• Cross Centre Building, Dallas, USA
• Los Angeles, Home Depot Stadium
• Qualcomm Stadium, San Diego, USA
• SNET Headquarters, New Haven, USA
• TV tower, Shanghai, China
• Grand Ole Opera Hotel, Nashville, USA
2G commercial radio services 3G (+ 2G) services
• Maracaña Stadium, Rio de Janeiro
• KPE Expressway, Singapore
• Alcatel-Lucent Headquarter, Paris
• Casino, Macao
• Swiss Railways
• Harbour Tunnel, Sydney, Australia
WiFi services
• Princeton University, US
• Quinnipiac University, US
• Metro Moscow
• Rio de Janeiro, TIM offices, Brazil
• Curitiba, BrT offices, Brazil
• RFS Germany and RFS Brazil offices
• Metro Shanghai
• Metro Guangzhou
• Metro Bangkok
• Metro Singapore
• Metro Hannover
• Metro Copenhagen• Metro Munich
• Metro Hong Kong
• Metro Shenzhen
• Metro Taipei
• Metro Buen. Aires
• Metro Chicago
• Metro Niagara
• Metro Rio de Jan.
RFS: A leader in Wireless Indoor Solutions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 7/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 6
Accessories
• Connectors,• Clamps,
• Installation tools
ClearFill Line Product Attached Services
Radiating Cable
• Best in class radiating cable portfolio for all type of mission critical or commercial services
• Narrowband / broadband -- Horizontal / vertical polarization
Passive DAS (Distributed Antenn a System) Portfol io
• Services: All -> Ultra broadband• Distributes high power (BTS) RF signal into various low power antenna points with low loss RF cable
(Cellflex, Cellflex Lite)
• (Ultra-) broadband indoor antennas and indoor passive RF components (couplers, splitters)
Appl ications
• Provide coverage to mission critical & commercial services to confined areas like tunnels and buildings
Design Services
• Design services to design complete e2e
tunnel / building coverage systems- Pre-Sales
- Post Sales
- Acceptance- Installation
supervision- Maintenance
Appl icati ons
• Provide in-tunnel and in-buildingcoverage to mission critical and
commercial services
RFS: A leader in Wireless Indoor Solutions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 8/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 7© Radio Frequency Systems 2009. All rights reserved
The in-building coverage challenges
Work
23%
Home
21%
Other
Indoor 30%
Car
14%
Other
locations
12%
@ 5000 MHz
70% of all calls coming
from indoor
70% of all calls coming
from indoor
Problem of Signal Penetration
When frequencies go up !!
Problem of Signal Penetration
When frequencies go up !!
The higher the data rate
The lower the
coverage probability
The higher the data rate
The lower the
coverage probability
85% of data sessions
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 9/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 8
In-building coverage solutions for building scenarios - DAS
Best in class coverage systems for commercial and
for mission critical multi-carrier / multi-service
applications of building scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 10/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 9
In-building coverage solutions for building scenarios - DAS
ClearFill LineCables, antennas, components
All kind of build ing scenarios, e.g.
– Small, mid-size and large buildings
– Office buildings
– Hotels
– Industrial plants
– Campus areas,
– Hospitals
– Airports
– Mines
– Ships
– Vessels
Ultra – wideband solutions for all kind ofservices, frequencies, e.g.
– FM – VHF
– UHF
– TETRA
– GSM900, GSM1800, UMTS, LTE
– CDMA
– WLAN 2.4 GHz and 5 GHz
– WiMAX
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 11/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 10
In-building coverage solutions for building scenarios - DAS
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
to DAS
GSM900
BTS,
UMTS2100
NodeB
GSM1800
BTS
900
1800 Σ
2100
Triplexer MBCS-9/18/21
900/1800/2100 MHz
Single and/or multiple Operators possible
For multiple Operators / multib and
application please note
RFS Broadband Coup ler series
BBC44*
Wide variety of
-Diplexers- Triplexers
- Multiband / Broadband Combiner
-Splitters (Reactive and Wilkinson)
- Directional couplers
-Tappers available
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 12/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 11
In-building coverage solutions for building scenarios - DAS
2-way, 3-way and 4-way splitters for equal splitting
Directional couplers (coupling values 5dB,
6dB, 7dB, 8dB, 10dB, 15dB, 20dB, 30dB) for
unequal splitting to compensate feeder cable
loss at higher floors
5th floor
4th floor
3rd floor
2nd floor
1st floor
Ground floor Directional Coupler 10dB
Directional Coupler 10dB
Directional Coupler 6dB
Directional Coupler 6dB
2-Way Power Splitter
from/to Triplexer / RF source (BTS, OAR, etc)RF distri bution v ia Coaxial Feeder cable, e.g.
CELLFLEX cable LCF 12-50 JFN
Other types (LCF78-50JFNA, LCF114-50JFNA)
can be used for loss reduction
Broadband and Ultra-
broadband
omnidirectional and
directional antennas
available
(e.g. 800 MHz-2700 MHz
698 MHz – 2700 MHz
350 MHz – 6000 MHz)
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 13/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 12
In-building coverage solutions for building scenarios - DAS
Basic Indoor Link Budget
• Coverage for 50 by 50 meters
• 1,2 or 4 antenna set-up
• 1 antenna for open space
• 2 antenna for moderate dense
• 4 antenna for heavy dense
No of antennas per building block 1 2 4
Power Level @ Building Block Input [dBm] 10 10 10
2 Way Power Splitter Loss [dB] -3.5
4 Way Power Splitter Loss [dB] -7
LCF12-50JFN, 25m, Loss [dB] -2.7LCF12-50JFN, 37,5m, Loss [dB] -4.04
LCF12-50JFN, 50m, Loss [dB] -5.4
Antenna feeding power level [dBm] 7.3 2.5 -2.4
Common Pathloss Model
Antenna Gain [dBi] 2 2 2
Path Loss for 35m (LOS), [dB] -70
Path Loss for 28m (LOS), [dB] -68
Path Loss for 18m (LOS), [dB] -64
Reflection Fading Margin [dB] -6 -6 -6
Wall loss inside building block [dB] -20 -10 0Predicted Reception Level @ Mobile [dBm] -86.7 -79.5 -70.4
Link b udget for Building Block (50m x 50m) - 2100MHz - Downlink
Typical attenuation values
Type of Material
Atten .
[dB]
@900MHz
Atten .
[dB]
@1850MHz
Atten .
[dB]
@2400MHz
Basement or foundation wall 13 14 15
Brick, concrete and concrete block 13 14 15
Cubicle wall 1 1.5 2
Drywall or sheetrock 2 2.5 3
Elevator or metallic obstacle 5 8 10
Glass door or window, no tint 2 2.5 3
Metallic rack 6 6 6
Wooden door 2 2.5 3
(source : Wireless Valley)
Building Block
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 14/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 13
In-building coverage solutions for building scenarios - DAS
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
Power Splitters
700/2700MHz350/6000MHz 700/2700MHz 700/2700MHz800/2500MHz
70/2700MHz380/2500MHz
800/2700MHz
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 15/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 14
In-building coverage solutions for building scenarios - DAS
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
Power Splitters, selected items
Description RFS Model - Name
2 Way Power Divider, Reactive, 698-2700MHz, N female, IP67 PDC2E-698/2700
3 Way Power Divider, Reactive, 698-2700MHz, N female, IP67 PDC3E-698/2700
4 Way Power Divider, Reactive, 698-2700MHz, N female, IP67 PDC4E-698/2700
2 Way Power Divider, Reactive, 700-2700MHz, 7-16 female, IP65 PD2DE-700/2700
3 Way Power Divider, Reactive, 700-2700MHz, 7-16 female, IP65 PD3DE-700/2700
4 Way Power Divider, Reactive, 700-2700MHz, 7-16 female, IP65 PD4DE-700/2700
2 Way Power Divider, Reactive, 380-2500MHz, N female, IP65 PDC2-380/2500
3 Way Power Divider, Reactive, 380-2500MHz, N female, IP65 PDC3-380/2500
4 Way Power Divider, Reactive, 380-2500MHz, N female, IP65 PDC4-380/2500
2 Way Power Divider, 700-2700MHz, N female, IP65 PDS2DE-700/2700
3 Way Power Divider, 700-2700MHz, N female, IP65 PDS3DE-700/2700
4 Way Power Divider, 700-2700MHz, N female, IP65 PDS4DE-700/2700
3 Way Power Divider, 800-2500MHz, N female, IP65 PDS3-800/2500
4 Way Power Divider, 800-2500MHz, N female, IP65 PDS4-800/2500
2 Way Power Divider, Wilkinson, 698-2700MHz, N female, In-Line Indoor PDCW2-698/2700
3 Way Power Divider, Wilkinson, 698-2700MHz, N female, In-Line Indoor PDCW3-698/2700
4 Way Power Divider, Wilkinson, 698-2700MHz, N female, In-Line Indoor PDCW4-698/2700
2 Way Power Divider, Wilkinson, 800-2500MHz, N female, Opposed Indoor PDCWO2-800/2500
3 Way Power Divider, Wilkinson, 800-2500MHz, N female, Opposed Indoor PDCWO3-800/2500
4 Way Power Divider, Wilkinson, 800-2500MHz, N female, Opposed Indoor PDCWO4-800/2500
2 Way Power Divider, Wilkinson, 350-6000MHz, N female, Opposed Indoor PDWO2-350/6000
4 Way Power Divider, Wilkinson, 350-6000MHz, N female, Opposed Indoor PDWO4-350/6000
2 Way Power Divider, Wilkinson, 70-2700MHz, N female, In-L ine, IP67 PDW2E-70/2700
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 16/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 15
In-building coverage solutions for building scenarios - DAS
Typical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTSSolution by use of dedicated Antennas
Broadband Combiner, Diplexer, Triplexer
380/2500MHz
Diplexer Triplexer
900/1800/2100 MHz
700/2700MHz
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 17/73
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 18/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 17
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellular services GSM900 / GSM1800 / UMTS
Solution by use of dedicated Antennas
Directional Coupler, Hybrid Coupler, Tapper
Directional Coupler 5dB, 6dB, 7dB, 8dB, 10dB, 15dB, 20dB, 30dB
Different bands
Tapper 3:1, 4:1, 7:1, 10:1, 20:1, 30:1
380/2700 MHz
Hybrid Coupler
Different bands
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 19/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 18
In-building coverage solutions for building scenarios - DASTypical In-build ing scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of dedicated Antennas
Directional Coupler, Hybrid Coupler, Tapper, selected items
Description RFS Model - Name
3dB Directional Hybrid Coupler, 380-2500MHz, 7-16 female, IP65 CD3DE-380/2500
3dB Directional Hybrid Coupler, 380-2500MHz, N female, IP65 CD3E-380/2500
3dB Directional Hybrid Coupler, 700-2700MHz, 7-16 female, IP65 CD3DE-700/2700
3dB Directional Hybrid Coupler, 700-2700MHz, N female, IP65 CD3E-700/2700
3dB Directional Hybrid Coupler, 380-520MHz, 7-16 female, IP65 CD3DE-380/520
3dB Directional Hybrid Coupler, 380-520MHz, N female, IP65 CD3E-380/520
6dB Directional Coupler, 380-520MHz, N female, IP64 CD6E-380/520
10dB Directional Coupler, 380-520MHz, N female, IP64 CD10E-380/520
15dB Directional Coupler, 380-520MHz, N female, IP64 CD15E-380/520
20dB Directional Coupler, 380-520MHz, N female, IP64 CD20E-380/520
30dB Directional Coupler, 380-520MHz, N female, IP64 CD30E-380/520
6dB Directional Coupler, 380-2700MHz, N female, IP67 CD6E-380/2700
10dB Directional Coupler, 380-2700MHz, N female, IP67 CD10E-380/2700
15dB Directional Coupler, 380-2700MHz, N female, IP67 CD15E-380/2700
6dB Directional Coupler, 698-2700MHz, N female, IP65 CD6E-700/2700
10dB Directional Coupler, 698-2700MHz, N female, IP65 CD10E-700/2700
20dB Directional Coupler, 698-2700MHz, N female, IP65 CD20E-700/2700
30dB Directional Coupler, 698-2700MHz, N female, IP65 CD30E-700/2700
6dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD6DE-700/2700
10dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD10DE-700/2700
20dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD20DE-700/2700
30dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD30DE-700/2700
3:1 Unequal Power Divider / Tapper , 380-2700 MHz, N female, IP68 TP3E-380/2700
4:1 Unequal Power Divider / Tapper , 380-2700 MHz, N female, IP68 TP4E-380/2700
7:1 Unequal Power Divider / Tapper , 380-2700 MHz, N female, IP68 TP7E-380/2700
10:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP10E-380/2700
20:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP20E-380/2700
30:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP30E-380/2700
Hybrid Coupler
Directional Coupler
Tapper
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 20/7328/03/2011 © Radio Frequency Systems 2011. All rights reserved 19
In-building coverage solutions for building scenarios - DASTypical In-build ing scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of dedicated Antennas
Indoor antennas
Indoor omni antenna, triple band, 806-2500 MHz I-ATO2-800/2500
Indoor omni antenna, triple band, 806-2500 MHz, with plate for ceiling mount I-ATO3-800/2500
Indoor panel antenna, triple band, 806-2500 MHz I-ATP2-800/2500
Indoor omni antenna, triple band, 800-2700 MHz I-ATO1-800/2700
Indoor panel antenna, triple band, 800-2700 MHz I-ATP1-800/2700
Indoor omni antenna, triple band, 690-2500 MHz I-ATO1-690/2500
Indoor panel antenna, triple band, 690-2500 MHz I-ATP1-690/2500
Indoor panel antenna, triple band, 690-2500 MHz I-ATP2-690/2500
Indoor omni antenna, triple band, 698-2700 MHz I-ATO1-698/2700
Indoor panel antenna, triple band, 698-2700 MHz I-ATP1-698/2700
Indoor directional antenna, triple band, 698-2700 MHz I-ATD1-698/2700
Indoor omni antenna, broadband, 2400-5875 MHz, Wifi/WLAN/WIMAX ready I-ATO1-2400/5875
Indoor omni antenna, ultra broadband, 690-6400 MHz, 2G/3G/Wifi/WLAN/Wimax ready I-ATO1-690/6400
Mounting Kit for indoor omni antenna I-ATO1-690/6400 I-ATO1-690/MKIT
Indoor omni antenna, ultra broadband, 380-6000 MHz, TETRA/DVB-H/2G/3G/Wifi/WLAN/Wimax ready I-ATO1-380/6000
Indoor omni antenna, ultra broadband, 806-6000 MHz, 7/16 female, 2G/3G/Wifi/WLAN/Wimax ready I-ATOD-806/6000
380/6000MHz690/6400MHz 2400/5875MHz800/2700MHz698/2700MHz
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 21/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 20
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTS
Solution by use of dedicated Antennas
CELLFLEX® Coaxial Cables
For the RF dis tribution to the antennas, our CELLFLEX cables LCF12-50JFN have been
mostly used. They offer excellent RF-parameters, e.g. low-loss, superior bending properties,
easy handling and installation, even under limited installation conditions . CELLFLEX cables
and accessories from RFS have been tested and proofed to ensure the highest quality of
system performance.
Consequently, CELLFLEX Cables LCF 78-50 JFNA / LCFS114-50JFNA can be used for long
cable runs between RF-source and antenna.
RFS CELLFLEX-LITE cables with Aluminium outer conductor can be an alternative for thecost – conscious customer.
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 22/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 21
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of dedicated Antennas
CELLFLEX® Coaxial Cables and accessories, selected items
Description RFS Model - Name
Feeder cable CELLFLEX LCF 12-50 JFN LCF12-50JFN
Connector 7/16 male for LCF12-50 716M-LCF12-D01
Connector N male for LCF12-50 NM-LCF12-D01
Earthing Kit for LCF 12-50 GKSPEED20-12P
Installation Clip for LCF 12-50 (kit of 10) RSB-12
Feeder cable CELLFLEX LCF 78-50 JFNA LCF78-50JFNA
Connector 7/16 female for LCF 78-50 716F-LCF78-D01
Earthing kit (GKSPEED), Earthing Wire 16 mm² (Premium Version) GKSPEED20-78P
Installation Clip for LCF 78-50 (kit of 10) RSB-78
Feeder cable CELLFLEX LCFS 114-50 JFNA LCFS114-50JFNA
Connector 7/16 female for LCF 78-50 716F-LCF114-D01
Earthing kit (GKSPEED), Earthing Wire 16 mm² (Premium Version) GKSPEED20-114P
Installation Clip for LCF 78-50 (kit of 10) RSB-114
Cellflex Cables LCFS114-50JFNA
Cellflex Cables LCF12-50JFN
Cellflex Cables LCF78-50JFNA
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 23/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 22
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellular services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
to DAS – Radiating cable
GSM900
BTS,
UMTS2100
NodeB
GSM1800
BTS
900
1800 Σ
2100
Triplexer MBCS-9/18/21
900/1800/2100 MHz
Single and/or mult iple Operators po ssible
For multiple Operators / mult iband
application please note
RFS Broadband Coup ler series
BBC44*
Wide variety of
-Diplexers- Triplexers
- Multiband / Broadband Combiner
-Splitters (Reactive and Wilkinson)
- Directional couplers
-Tappers available
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 24/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 23
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
PS 3
Connection to
Power Splitter 2
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 25/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 24
RF distribu tion via Coaxial Feeder cable,
e.g. CELLFLEX cable LCF 12-50 JFN
Other types (LCF78-50JFNA, LCFS114-50JFNA)
can be used for loss reduction
In-building coverage solutions for building scenarios - DASTypical In-build ing scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
P S 1
Power Splitter
2-way
Directional Coupler
P S 3
P S 2
Power Splitter
2-way
RADIAFLEX-cable
RLKU78-50JFLA
RADIAFLEX-cable
RLKU78-50JFLA
RADIAFLEX-cable
RLKU78-50JFLA
RADIAFLEX-cable
RLKU78-50JFLA
from/to Triplexer
RF source (BTS, OAR, etc)
2-way, 3-way and 4-way splitters
for equal splitting
Directional couplers (coupling values 5dB,
6dB, 7dB, 8dB, 10dB, 15dB, 20dB, 30dB) for
unequal splitting to compensate feeder cable
loss at higher floors
RADIAFLEX®- Radiating cables operate as dedicated antennas, providing a homogenous,
equal coverage along the cable run and are RF broadband. Therefore, they are highly
applicable for coverage extension in confined areas.
For In-building appl ications, our RADIAFLEX cable types RLKW12-50; RLKW78-50,
RLKU12-50, RLKU78-50, RCF12-50, RCF78-50 and RLKD12-50 are the best suitable
selection.
Antennas (Omni- and/or Panel) can be u sed in combination
with the RADIAFLEX cable
RADIAFLEX cable should
be always
terminated at section
end
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 26/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 25
In-building coverage solutions for building scenarios - DAS
RADIAFLEX® Radiating Cables – Basic Link Budget UMTS
Typical In-building scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
RF Output Power (CPICH) per channel: + 20 dBm
Triplexer loss: - 1.3 dB
Directional coupler (6 dB): - 6.5 dB2-way Splitter: - 3.5 dB
Feeder Cable Loss: - 1.5 dB
Input Power at beginning of the Radiating cable: + 7.2 dBm
As per data sheet (RLKU78-50JFNA):
Longitudinal loss per 100 m = 10 dBConsequently at 100 m System Length - 10 dB
Coupling Loss in 2 m distance (95%): - 69 dB
Received signal strength level (CPICH) @ 2m distance: - 71,8 dBm
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 27/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 26
In-building coverage solutions for building scenarios - DASTypical In-build ing scenario for cellu lar services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
RADIAFLEX® Radiating Cables, selected items for In-build ing scenarios
RLK series:
For applications in tunnels and buildings
where low coupling loss variations are
required.
RLKW12-50JFNA (JFLA), up to 1950 MHz
RLKW78-50JFNA (JFLA), up to 1950 MHz
RLKU12-50JFNA (JFLA), up to 2700 MHz
RLKU78-50JFNA (JFLA), up to 2700 MHzRLKD12-50JFNA (JFLA), up to 6000 MHz
.
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 28/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 27
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellu lar serv ices GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
RADIAFLEX® Radiating Cables, selected items for In-build ing scenarios
RCF series:
For applications where particularly small
bending radii are required for heavy-duty
applications (e.g. mines, ships, vessels).
RCF12-50JFN (JFL), up to 6000 MHz
RCF78-50JFNA (JFLA), up to 2650 MHz
RSF12-50JFN (JFL), up to 6000 MHz
.
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 29/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 28
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellular services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
RADIAFLEX® Radiating Cables, selected items for In-build ing scenarios
Description RFS Model-Name
Radiaflex® cable 1/2", RLKW-series RLKW12-50JFLARadiaflex® cable 1/2", RLKU-series RLKU12-50JFLA
Connector N-female NF-RA12-012
Connector N-male NM-RA12-011
Round base, 80 mm, flame retardant RB-80-4
Clic-clamp, flame retardant, for 1/2" cables CC-12-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 125 mm, for plastic plug SC-45125-2
Terminating resistance, N-male, 1 W N-TER-01
Radiaflex® cable 7/8", RLKW-series RLKW78-50JFLA
Radiaflex® cable 7/8", RLKU-series RLKU78-50JFLA
Connector N-female NF-RA78-016
Connector 716-female 716F-RA78-016
Round base, 80 mm, flame retardant RB-80-4
Clic-clamp, flame retardant, for 7/8" cables CC-78-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 125 mm, for plastic plug SC-45125-2
Terminating resistance, N-male, 1 W N-TER-01
RADIAFLEX-cable 1/2" RLK* - series (foil cable) and accessories for In-buildin g scenarios
RADIAFLEX-cable 7/8" RLK* - series (foil cable) and accessories for In-building scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 30/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 29
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellular services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
RADIAFLEX® Radiating Cables, selected items for In-build ing scenarios
Description RFS Model-Name
Radiaflex® cable 1/2", RCF-series RCF12-50JFN
Connector 7/16 male for RCF12-50 716M-LCF12-D01
Connector N male for RCF12-50 NM-LCF12-D01
Round base, 50 mm, flame retardant RB-50-4
Clic-clamp, flame retardant, for 1/2" cables CC-12-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 95 mm, for plastic plug SC-45195-1
Terminating resistance, N-male, 1 W N-TER-01
Radiaflex® cable 7/8", RCF-series RCF78-50JFNA
Connector 7/16 male for RCF78-50 716M-LCF78-D01
Connector N male for RCF78-50 NM-LCF78-D01
Round base, 50 mm, flame retardant RB-50-4
Clic-clamp, flame retardant, for 7/8" cables CC-78-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 95 mm, for plastic plug SC-45195-1
Terminating resistance, N-male, 1 W N-TER-01
RADIAFLEX-cable 7/8" RCF* - series (corrugated cable) and accessories for In-bui lding scenarios
RADIAFLEX-cable 1/2" RCF* - series (corrugated cable) and accessories for In-bui lding scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 31/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 30
In-building coverage solutions for building scenarios - DASTypical In-building scenario for cellular services GSM900 / GSM1800 / UMTS
Solution by use of RADIAFLEX® Radiating cables
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 32/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 31
Best in class coverage systems for
commercial and for mission critical
multi-carrier / multi-service applications
of metro, rail and road tunnels
In-tunnel coverageCoverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 33/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 32
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
RADIAFLEX® – CableRAYS158-50JFLA
Section length appr. 500m
RADIAFLEX® – Cable
RAYS158-50JFLA
Section length appr. 500m
RADIAFLEX® – CableRAYS158-50JFLA
Section length appr. 500m
Power Divider 4-way Power Divider 4-way
Tunnel n iche
Optic Fibre
Optic Fibre Optic Fibre Optic Fibre
RADIAFLEX® – Cable
RAYS158-50JFLA
Section length appr. 500m
500m
0 m500m 1000m 1500m 2000m
Tunnel niche Tunnel niche Tunnel niche
Optic Fibre
Power Divider 2-way
RADIAFLEX®- Radiating cables operate as dedicated antennas,
providing a homogenous, equal coverage along the cable run
and are RF broadband. Therefore, they are highly applicable for
coverage extension in train tunnels, metros, road tunnels, station areas, etc.
2-way, 3-way and 4-way
splittersfor equal splitting
Coaxial Feeder cables , e.g. CELLFLEX cable
LCF 12-50 JFN.
Other types (LCF78-50JFNA, LCFS114-50JFNA;
LCF158-50JFNA) can be used for loss reducti on
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 34/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 33
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables – Link budget
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 35/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 34
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables – Link budget
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 36/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 35
RADIAFLEX® Radiating Cables
The most appropriated system solution for all kind of tunnels, station
areas, mines, ships, vessels, and specific In-building areas is the
installation of RFS RADIAFLEX®- cables.
The RADIAFLEX®- cable functions as a distributed antenna to provide
communications in tunnels, mines and large building complexes and is the
solution for any application in confined areas.
Slots in the copper outer conductor allow a controlled portion of the
internal RF energy to be radiated into the surrounding environment.
Conversely, a signal transmitted near the cable will couple into the slots
and be carried along the cable lengths.
RADIAFLEX®- cables are used for both one-way and two-way
communication systems and because of its broadband capability, a single
radiating cable can handle multiple communication systems
simultaneously. By combining passive devices (e.g. splitters) and radiating
cables improve and extend coverage in an cost optimized way.
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 37/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 36
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
• RFS RADIAFLEX: World's largest portfolio of radiating
cables; global leadership (technology, market share)
• Lower cost/best service:
- Multi-band
-Future-proof
• Best coverage:
- No shading by vehicles
- Smooth everywhere, even in trains
- Proven safety : low smoke, flame & fire retardance
- Better reliability vs antennas
-
Tested up to 6 GHz- DVB-H, DVB-SH, WiMAX, LTE ready
- Live test environment in Hanover metro
- Not sensitive to reflection
- Less sensitive to wind
Typical environments
• Many curves, Small tunnel cross section
RADIAFLEX® Radiating Cables
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 38/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 37
RADIAFLEX® Radiating Cables
RADIAFLEX®- radiating cables operate as dedicated antennas and are RF broadband. Therefore, they
are highly applicable to extend the coverage and offer many important advantages:
Homogenous coverage along the RADIAFLEX® - cable
Can be installed in accordance to the shape of the building
Lower dynamic range compared with an antenna solution
Multi-band solution
Multi-operator solution
Easy to upgrade
Easy system planning
Controlled coverage
Better network security
Minimized interference
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 39/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 38
RADIAFLEX® Radiating Cables vs Antennas
Pros:
• Good for large cross-sections
• Installation effort
Cons:
• Not broadband
• Not upgradeable
• Low frequencies
• Line of sight
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 40/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 39
RADIAFLEX® Radiating Cables: Features/Benefits
• RFS RADIAFLEX: World's largest portfolio of
radiating cables; global leadership (technology,
market share)
• Lower cost/best service:
- Multi-band
- Future-proof
• Best coverage:
- No shading by vehicles or additional walls
- Smooth everywhere, even in trains
-Proven safety : low smoke, flame & fire retardance
- Better reliability vs antennas
- Tested up to 6 GHz
- DVB-H, DVB-SH, WiMAX, LTE ready
- Live test environment in Hanover metro
- Not sensitive to reflection
- Less sensitive to wind
Typical environments• Multiband applications
• FM / VHF / UHF appl ications
• Building structures with many lossy
walls
• Building / tunnels with many curves
• Small tunnel cross sections
• Industrial plants with metallic high rise
racks
• Ships/Vessels with metallized wall
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 41/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 40
FM
PMR PMR
TETRA
PMR
TETRAPOL
CDMA
TDMA
GSM900
GSM-R
LTE
UMTS900
GSM1800
PCN
DECT UMTS2100
LTE
ISM
WLAN
WIFI
WiMax WiMax
WLAN
WIFI
75-110 MHz 150-170 MHZ380-500 MHz 698-960 MHz 1.7-1.9 GHz 1.9-2.2 GHz 2.4-2.7 GHz 3.5 GHz 5-6 GHz
ALFU12-50A + + + + + + + - -
RLF78-50A +++ ++ + ++ - - - - -
RLF114-50A +++ ++ + ++ - - - - -
RLF158-50A ++ ++ + ++ - - - - -RLFW78-50A + + + + + - - - -
RLFW114-50A + + + + + - - - -
RLFW158-50A + + + + + - - - -
RLFU78-50A ++ ++ + ++ +++ +++ - - -
RLFU114-50A ++ ++ + ++ ++ +++ - - -
RLFU158-50A ++ ++ + ++ +++ +++ - - -
RLKL78-50A ++++ ++++ +++ - - - - - -
RLKL114-50A ++++ ++++ +++ - - - - - -
RLK12-50A ++++ +++ ++++ +++ - - - - -
RLK78-50A ++++ +++ ++++ +++ - - - - -
RLK114-50A ++++ ++ ++++ +++ - - - - -RLK158-50A ++++ ++ ++++ +++ - - - - -
RLKW12-50A ++++ +++ +++ ++++ ++++ - - - -
RLKW78-50A ++++ +++ +++ ++++ ++++ - - - -
RLKW114-50A +++ +++ +++ ++++ ++++ - - - -
RLKU12-50A ++ ++ + +++ +++ ++++ ++++ - -
RLKU78-50A ++ ++ + ++ +++ ++++ ++++ - -
RLKU114-50A ++ ++ + ++ +++ ++++ ++++ - -
RLKU158-50A ++ + + ++ +++ ++++ ++++ - -
RLKU158-50AE ++ + + +++ ++++ ++++ - - -
RLKU158-50AH ++ + + +++ ++++ ++++ ++++ - -
RLKD12-50A - - - +++ +++ +++ +++ ++++ ++++
L o w
c o u p l i n g l o s s
1 / 2 " t o 7 / 8 " : r e c o m m e n d e d i n b u i l d i n g s
7 / 8 " t o 1 5 / 8 " : r e c o m m e n d e d f o r t u
n n e l s
G r o u p s o f a p e r t u r e s a t s h o r t i n t e
r v a l s
Technology
(Frequency)
Cable types Remarks
Type
of
apertures
N e g l i g i b l e i n f l u e n c e o f
d u s t / s a l t / m o i s t u r e a c c u
m u l a t i o n o n
c a b l e l o s s
G r o u p s o f a p e r t u r e s a t l a r g e i n t e r v a l s
( s i n g l e l e n g t h s s h o u l d n o t b e
l e e s t h a n 8 0 m
( 2 6 2 f t )
RADIAFLEX Selection Guide 1/2
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 42/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 41
RADIAFLEX Selection Guide 2/2
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
FM
PMR PMR
TETRA
PMR
TETRAPOL
CDMA
TDMA
GSM900
GSM-R
LTE
UMTS900
GSM1800
PCN
DECT UMTS2100
LTE
ISM
WLAN
WIFI
WiMax WiMax
WLAN
WIFI
75-110 MHz 150-170 MHZ380-500 MHz 698-960 MHz 1.7-1.9 GHz 1.9-2.2 GHz 2.4-2.7 GHz 3.5 GHz 5-6 GHz
RLV114-50A ++ ++ ++ ++++ - - - - -Standard length
1,000 m (3,281 ft)
RLV158-50A ++ ++ ++ ++++ - - - - - Standard length1,000 m (3,281 ft)
RLVU114-50A + + + +++ ++++ ++++ - - -Standard length
500 m (1,641 ft)
RLVU158-50A + + + +++ ++++ ++++ - - -Standard length
800 m (2,625 ft)
RLVU114-50AB + + + ++ ++++ ++++ ++++ - -Standard length
500 m (1,641 ft)
RLVU158-50AB + + + ++ ++++ ++++ ++++ - -Standard length
800 m (2,625 ft)
RAY78-50A +++ ++ +++ ++++ - - - - -
RAY114-50A ++ + +++ ++++ - - - - -
RAY158-50A ++ + +++ ++++ - - - - -
RAY78-50AB +++ ++ +++ ++++ - - - - -
RAY114-50AB +++ + +++ ++++ - - - - -
RAYS158-50 ++ ++ ++ ++++ ++++ ++++ ++++ - -
RAYU158-50A + + + ++++ ++ ++ - - -
RSF12-50 + + + + + + + + +
RCF12-50 + + + + + + + + +
RCF78-50A + + + + + + + + -
RCF114-50A + + + + + + + - -
RCF158-50A + + + + + + + - -
RHCA12-50 + + + + + + + + + Plenum rated
- L o w
c o u p
l i n g
l o s s
- O p
t i m
i z e
d f o r
d i g i t a l
t r a
n s m
i s s
i o n
G r o u p s o
f s
l o p e s
l o t s a
t
s h o
r t i n t e r v a
l s
- C u r r i g a
t e d o u
t e r
c o n
d u c
t o r
- R o
b u s
t , l o w
b e n
d i n g r a
d i u s
M i l l e d s
l o t s
V a r i o c a
b l e s
- g r a
d e
d g r o u p s
o f
a p e r t u r e s
Technology
(Frequency)
Cable types Remarks
Type
of
apertures
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 43/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 42
RLK series:
For applications in tunnels and buildingswhere low coupling loss variations are
required.
RLKW12-50JFNA (JFLA), up to 1950 MHz
RLKW78-50JFNA (JFLA), up to 1950 MHz
RLKU12-50JFNA (JFLA), up to 2700 MHz
RLKU78-50JFNA (JFLA), up to 2700 MHzRLKD12-50JFNA (JFLA), up to 6000 MHz
.
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables, selected items for In-build ing scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 44/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 43
RADIAFLEX® Radiating Cables, selected items for In-building scenarios
RCF series:
For applications where particularly small
bending radii are required for heavy-duty
applications (e.g. mines, ships, vessels).
RCF12-50JFN (JFL), up to 6000 MHz
RCF78-50JFNA (JFLA), up to 2650 MHz
RSF12-50JFN (JFL), up to 6000 MHz
.
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 45/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 44
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
RLK series (RLK, RLKL, RLKW, RLKU):
For applications in tunnels and buildingswhere low coupling loss variations are
required.
RLKW78-50JFNA (JFLA), up to 1950 MHz
RLKW114-50JFNA (JFLA), up to 1950 MHz
RLKU78-50JFNA (JFLA), up to 2700 MHz
RLKU114-50JFNA (JFLA), up to 2700 MHz
RLKU158-50JFNA (JFLA), up to 2700 MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 46/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 45
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
RAY series (RAY, RAYU, RAYS):
For applications in tunnels and buildings
where low coupling loss variations are
required.
RAY78-50JFNA (JFLA), up to 1000 MHz
RAY114-50JFNA (JFLA), up to 1000 MHz
RAY158-50JFNA (JFLA), up to 1000 MHzRAYS158-50JFNA (JFLA), up to 2700 MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 47/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 46
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
RLF series (RLF, RLFW, RLFU, ALFU):
For heavy-duty wideband and multi-useapplications in all kind of tunnels. Due to
widely separated slot-groups very insensitive
against environmental influences (esp. Salt).
RLF78-50JFNA (JFLA), up to 1000 MHz
RLF114-50JFNA (JFLA), up to 1000 MHz
RLF158-50JFNA (JFLA), up to 1000 MHzRLFU78JFNA, (JFLA), up to 2400 MHz
RLFU114-50JFNA (JFLA), up to 2400 MHz
RLFU158-50JFNA (JFLA), up to 2400 MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 48/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 47
RCF ser ies (RCF, RSF, RHCA):
For applications where particularly small
bending radii are required for heavy-dutyapplications (e.g. mines, ships, vessels).
RCF12-50JFN (JFL), up to 6000 MHz
RCF78-50JFNA (JFLA), up to 2650 MHz
RSF12-50JFN (JFL), up to 6000 MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 49/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 48
RADIAFLEX® Clamps
Plastic dowel Ø 6mm
(hole Ø 6mm, 40mm deep)
(Plug-6-1)
Round base H = 50mm (RB-50-4)
Round base H = 80mm (RB-80-4)
Clic clamp
(CC-38-2, CC-12-2, CC-58-2,
CC-78-2, CC-114-2, CC-158-2)
Screw (SC-4595-1)(for 50mm Round base)
Screw (SC-45125-2)(for 80mm Round base)
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 50/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 49
RADIAFLEX® Clamps
Plug for 50mm Round
base (Plug-6-3S)
Plug for 80mm Roundbase (Plug-6-4S)
Round base H = 50mm
(RB-50-4)
Round base H = 80mm
(RB-80-4)
Clic clamp(CC-38-2, CC-12-
2, CC-58-2, CC-
78-2, CC-114-2,
CC-158-2)Clic flat nut
M6 (CS-6-1)
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 51/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 50
RADIAFLEX® Clamps
Example for installation
on anchor bar
M4 nut
Round base
H = 50mm or H = 80mm
Clic clamp
M4 Torx screw
for Round Base H = 50mm: M4 x 75
for Round Base H = 80mm: M4 x 105
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 52/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 51
RADIAFLEX® Clamps: Heavy Duty Clamp HDC for 350km/h
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
HDC-*** are
special clamps
for train speed
up to 350km/h
Screw S-890-1
WasherW-8.4-1 and
Spring washer SW-
8.0-1
PLUG-8-2
Setting tool TOOL-2
HDC-114-110-01
HDC-158-110-01
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 53/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 52
RADIAFLEX® Clamps: Heavy Duty Clamp HDC for 350km/h
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Available for the cable seizes of 11/4“ & 15/8“
of the cable series RLF, RLK, RLV and RAY.
Optional up to 4 additional cl ic-clamps
could be mounted e.g. optic backbone
cables. Suitable types are CC-12-2,
CC-58-2 & CC-78-2
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 54/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 53
RADIAFLEX® Clamps: Heavy Duty Clamp HDC for 350km/h
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Fixing with approved
stainless steel plug
Plug for HDC clamp (Plug-6-5S)
HDC clamp
(HDC-114-110-01or
HDC-158-110-01)
Washer
(W-64-1)
Nut
(N-M6-1)
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 55/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 54
RADIAFLEX® Clamps: Fire protection clamp
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Special solution for
fire protecting.
Installation
recommended
every 8-10m
Round base RB-50-4
or RB-80-4
Screw M8 x 65 (S-865-1)
or M8 x 95 (S-895-1)
RSB clip
Metal dowel
PLUG-8-2
Setting toolTOOL-2
Drill out if necessary (8.5
mm)
WasherW-84-1
In case of fire the resistant part of the fixing w ill hold the cable in position and
enables the cable to keep in operation as long as the cable itself allows. It also
prevents the cable from detaching from the wall that might b lock any escape
route.
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 56/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 55
RADIAFLEX® Clamps: Messenger wire installation
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Special solution for external messenger w ireTASS 2
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 57/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 56
Termination Loads, selected items
Two different Groups
- Low power 1W - 50W
- High power > 50W ( on request )
- Low PIM ( on request )N-TER-01
N-TER-10
N-TER-50
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 58/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 57
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Accessories: Grounding kits , DC-Blocks, EMP-protectors, selected items
DC-Block to protect equipment
and personnel due to induced voltages
from the catenary/overhead line
EMP-Protector (Surge-Suppressor) for lightningto protect
equipment and personnel
Is needed in order to carried outpotential equalization current
EMP protector
is recommended
whenever an outdoor
device is linked
RADIAFLEX cable shou ld
be always
terminated
Coaxial Feeder cables, e.g. CELLFLEX cable
LCF 12-50 JFN, or factor-fit ted Jumper cables.
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 59/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 58
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
Description RFS Model-Name
RADIAFLEX-cable 7/8" RLK*, RAY* - series (foil cable) and accessories fo r Tunnel scenarios
Radiaflex® cable 7/8", RLKW-series RLKW78-50JFLA
Radiaflex® cable 7/8", RLKU-series RLKU78-50JFLA
Radiaflex® cable 7/8", RAY-series RAY78-50JFLAConnector N-female NF-RA78-016
Connector 7-16-female 716F-RA78-016
Round base, 80 mm, flame retardant RB-80-4
Clic-clamp, flame retardant, for 7/8" cables CC-78-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 125 mm, for plastic plug SC-45125-2
Terminating resistance, N-male, 1 W N-TER-01
RADIAFLEX-cable 1 1/4" and accessor ies (foil cable) and accessor ies for Tunnel scenarios
Radiaflex® cable 1 1/4", RLKW-series RLKW114-50JFLA
Radiaflex® cable 1 1/4", RLKU-series RLKU114-50JFLA
Radiaflex® cable 1 1/4", RAY-series RAY114-50JFLA
Connector 7-16-female 716F-RA114-016
Round base, 80 mm, flame retardant RB-80-4
Clic-clamp, flame retardant, for 1 1/4" cables CC-114-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 125 mm, for plastic plug SC-45125-2
Terminating resistance, N-male, 1 W N-TER-01
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 60/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 59
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables, selected items for Tunnel scenarios
Description RFS Model-Name
RADIAFLEX-cable 1 5/8" and accessori es (foil cable) and accessories for Tunnel scenarios
Radiaflex® cable 1 5/8", RLKW-series RLKW158-50JFLA
Radiaflex® cable 1 5/8", RLKU-series RLKU158-50JFLA
Radiaflex® cable 1 5/8", RAY-series RAY158-50JFLARadiaflex® cable 1 5/8", RAYS-series RAYS158-50JFLA
Connector 7-16-female 716F-RA158-016
Round base, 80 mm, flame retardant RB-80-4
Clic-clamp, flame retardant, for 1 5/8" cables CC-158-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 125 mm, for plastic plug SC-45125-2
Terminating resistance, N-male, 1 W N-TER-01
RADIAFLEX-cable 7/8" RCF* - series (corrugated cable) and accessories for In-buil ding scenarios
Radiaflex® cable 7/8", RCF-series RCF78-50JFNAConnector 7/16 male for RCF78-50 716M-LCF78-D01
Connector N male for RCF78-50 NM-LCF78-D01
Round base, 50 mm, flame retardant RB-50-4
Clic-clamp, flame retardant, for 7/8" cables CC-78-2
Nylon plug, 6 x 30 mm PLUG-6-1
Screw,4.5 x 95 mm, for plastic plug SC-45195-1
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 61/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 60
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables accessories, selected items for Tunnel scenarios
Description RFS Model-Name
Heavy duty clamp for 1 5/8" HDC-158-110-01
Plug 6 x 110.5 mm, set for HDC 114/158 (Kit of 150 pcs.) PLUG-6-5S
Nut DIN0985 M06 A2 6kt ssi N-M6-1
Washer, inner dia. 6.4 mm, stainless steel W-64-1
Heavy duty clamp for 1 1/4" HDC-114-110-01
Plug 6 x 110.5 mm, set for HDC 114/158 (Kit of 150 pcs.) PLUG-6-5S
Nut DIN0985 M06 A2 6kt ssi N-M6-1
Washer, inner dia. 6.4 mm, stainless steel W-64-1
Accessories for RADIAFLEX - Heavy Duty Clamp
Heavy Duty Clamp for RADIAFLEX Cable RLK158, RLKU158, RLF158, RLFW158, RLFU158, RLV158,
RLVU158, RAY158, RAYS158
Heavy Duty Clamp for RADIAFLEX Cable RLK114, RLKW114, RLKU114, RLF114, RLFW114, RLFU114, RLV114,
RLVU114, RAY114
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 62/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 61
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables accessories, selected items for Tunnel scenarios
RSB-Clip for 158 (kit of 10) RSB-158-001
Round base, 80 mm, flame retardant RB-80-4
Metal plug, 8 x 30 mm, stainless steel PLUG-8-2
Screw, 8.0 x 95 mm, for metal plug S-895-1
Washer, inner dia. 8.4 mm, stainless steel W-84-1
RSB-Clip for 114 (kit of 10) RSB-114
Round base, 80 mm, flame retardant RB-80-4
Metal plug, 8 x 30 mm, stainless steel PLUG-8-2
Screw, 8.0 x 95 mm, for metal plug S-895-1
Washer, inner dia. 8.4 mm, stainless steel W-84-1
Fire Protecti on Clamp f or RADIAFLEX Cable RLK158, RLKU158, RLF158, RLFW158, RLFU158, RLV158,
RLVU158, RAY158, RAYS158
Fire Protecti on Clamp f or RADIAFLEX Cable RLK114, RLKW114, RLKU114, RLF114, RLFW114, RLFU114, RLV114,
RLVU114, RAY114
Accessories for RADIAFLEX - Fire protect ion c lamp
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 63/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 62
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
RADIAFLEX® Radiating Cables accessories, selected items for Tunnel scenarios
DC block, 15 kV, 180-2500 MHz, 7-16 male - 7-16 female, IP65 DC-BLOCK-15-7MF
DC block, 4 kV, 160-2500 MHz, 7-16 male - 7-16 female, IP65 DC-BLOCK-4-7MF
DC-Blocks
Accessories for RADIAFLEX - DC Block
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 64/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 63
Power Splitters
700/2700MHz350/6000MHz 700/2700MHz 700/2700MHz800/2500MHz
70/2700MHz380/2500MHz
800/2700MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 65/73
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 66/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 65
Broadband Combiner, Diplexer
380/2500MHz
Diplexer Triplexer
900/1800/2100 MHz
700/2700MHz
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 67/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 66
Broadband Combiner, Diplexer, Triplexer, selected items
Description RFS Model - Name
Broadband Coupler 4-In/4-Out, 380-2500MHz, 7-16 female BBC44D-380/2500
Broadband Coupler 4-In/4-Out, 380-2500MHz, N female BBC44N-380/2500Broadband Coupler 4-In/4-Out, 698-2700MHz, 7-16 female BBC44D-700/2700
Broadband Coupler 4-In/4-Out, 698-2700MHz, N female BBC44N-700/2700
Diplexer, 800-960/1710-2170 MHz, N female, IP64 DBCE-800/2200
Diplexer, 80-2170/2400-2500 MHz, N female, Indoor DBC-80/2500
Triplexer, 880-960/1710-1880/1920-2170MHz, N female, IP65 MBC-9/18/21
Diplexer, 80-520/698-2700 MHz, 7-16 female, IP65 DBCD-80/2700
Diplexer, 80-520/698-2700 MHz, N female, IP65 DBC-80/2700Diplexer, 80-2700/3300-3800,4900-5850 MHz, N female, Indoor DBC-80/5850
Diplexer, 80-960/1710-2700 MHz, N-Female, Indoor DBC-80/2700-1
Diplexer, 80-2170/2400-2690 MHz, N-Female, Indoor DBC-80/2690
Diplexer, 80-2170/2490-2690 MHz, N-Female, Indoor DBC-80/2690-1
Diplexer, 800-960/1710-2170MHz, N female, IP64 DBCS-800/2170
Diplexer, 1710-1880/1920-2170MHz, N female, IP64 DBCS-1710/2170
Triplexer GSM/DCS/3G, N-female, IP64 MBCS-9/18/21
Broadband Combiner
Diplexer, Triplexer
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 68/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 67
Directional Coupler, Hybrid Coupler, Tapper
Directional Coupler 5dB, 6dB, 7dB, 8dB, 10dB, 15dB, 20dB, 30dB
Different bands
Tapper 3:1, 4:1, 7:1, 10:1, 20:1, 30:1
380/2700 MHz
Hybrid Coupler
Different bands
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 69/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 68
Directional Coupler, Hybrid Coupler, Tapper, selected items
Description RFS Model - Name
3dB Directional Hybrid Coupler, 380-2500MHz, 7-16 female, IP65 CD3DE-380/2500
3dB Directional Hybrid Coupler, 380-2500MHz, N female, IP65 CD3E-380/2500
3dB Directional Hybrid Coupler, 700-2700MHz, 7-16 female, IP65 CD3DE-700/2700
3dB Directional Hybrid Coupler, 700-2700MHz, N female, IP65 CD3E-700/2700
3dB Directional Hybrid Coupler, 380-520MHz, 7-16 female, IP65 CD3DE-380/520
3dB Directional Hybrid Coupler, 380-520MHz, N female, IP65 CD3E-380/520
6dB Directional Coupler, 380-520MHz, N female, IP64 CD6E-380/520
10dB Directional Coupler, 380-520MHz, N female, IP64 CD10E-380/520
15dB Directional Coupler, 380-520MHz, N female, IP64 CD15E-380/520
20dB Directional Coupler, 380-520MHz, N female, IP64 CD20E-380/520
30dB Directional Coupler, 380-520MHz, N female, IP64 CD30E-380/520
6dB Directional Coupler, 380-2700MHz, N female, IP67 CD6E-380/2700
10dB Directional Coupler, 380-2700MHz, N female, IP67 CD10E-380/2700
15dB Directional Coupler, 380-2700MHz, N female, IP67 CD15E-380/2700
6dB Directional Coupler, 698-2700MHz, N female, IP65 CD6E-700/2700
10dB Directional Coupler, 698-2700MHz, N female, IP65 CD10E-700/2700
20dB Directional Coupler, 698-2700MHz, N female, IP65 CD20E-700/270030dB Directional Coupler, 698-2700MHz, N female, IP65 CD30E-700/2700
6dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD6DE-700/2700
10dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD10DE-700/2700
20dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD20DE-700/2700
30dB Directional Coupler, 698-2700MHz, 7-16 female, IP65 CD30DE-700/2700
3:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP3E-380/2700
4:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP4E-380/2700
7:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP7E-380/2700
10:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP10E-380/2700
20:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP20E-380/2700
30:1 Unequal Power Divider / Tapper, 380-2700 MHz, N female, IP68 TP30E-380/2700
Hybrid Coupler
Directional Coupler
Tapper
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 70/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 69
CELLFLEX® Coaxial Cables
For the RF dis tribution to the RADIAFLEX-cable, our CELLFLEX cables LCF12-50JFN and
LCF78-50JFNA have been mostl y used. They of fer excellent RF-parameters, e.g. low -loss,
superior bending prop oerties, easy handling and ins tallation, even under limit ed installation
cond ition s . CELLFLEX cables and accessori es from RFS have been tested and proofed to
ensure the highest quality of system performance.
Consequently, CELLFLEX Cables LCF 78-50 JFNA / LCFS114-50JFNA and LCF158-50JFNA
can be used for long cable runs between BTS/NodeB/Remote Unit and Radiating cable.
RFS CELLFLEX-LITE cables with Aluminium outer conductor can be an alternative for the
cost – conscious customer.
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 71/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 70
CELLFLEX® Coaxial Cables and accessories, selected items
Description RFS Model - Name
Feeder cable CELLFLEX LCF 12-50 JFN LCF12-50JFN
Connector 7/16 male for LCF12-50 716M-LCF12-D01
Connector N male for LCF12-50 NM-LCF12-D01
Earthing Kit for LCF 12-50 GKSPEED20-12P
Installation Clip for LCF 12-50 (kit of 10) RSB-12
Feeder cable CELLFLEX LCF 78-50 JFNA LCF78-50JFNA
Connector 7/16 female for LCF 78-50 716F-LCF78-D01
Earthing kit (GKSPEED), Earthing Wire 16 mm² (Premium Version) GKSPEED20-78PInstallation Clip for LCF 78-50 (kit of 10) RSB-78
Feeder cable CELLFLEX LCFS 114-50 JFNA LCFS114-50JFNA
Connector 7/16 female for LCF 78-50 716F-LCF114-D01
Earthing kit (GKSPEED), Earthing Wire 16 mm² (Premium Version) GKSPEED20-114P
Installation Clip for LCF 78-50 (kit of 10) RSB-114
Cellflex Cables LCFS114-50JFNA
Cellflex Cables LCF12-50JFN
Cellflex Cables LCF78-50JFNA
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 72/73
28/03/2011 © Radio Frequency Systems 2011. All rights reserved 71
Typical Tunnel scenario - Solution by use of RADIAFLEX® Cables
Coverage solutions for Tunnel scenarios
Accessor ies : Grounding for CELLFLEX-Cables
Premium Grounding Kit for CELLFLEX - Cables
• complete with all relevant standards
• proof and resistant to all
environmental influences
• Compatible with both copper & aluminium
• easy and time saving ins tallation
For dismantling we
recommend to use the
JSTRIP-**-* tool
8/19/2019 Wiress Indoor Solutions, In-building and Tunnel Solutions
http://slidepdf.com/reader/full/wiress-indoor-solutions-in-building-and-tunnel-solutions 73/73
www.rfsworld.com
••••
•••••
•••••••••
••••••••••
DubaiJohannesburg
Kolkata
Madrid
Monza
New Delhi
Paris
Pacy
Trignac/Lannion
Coconut CreekMansfield
Meriden
Naperville
San Jose
BangkokBeijing
Guangzhou
Hong Kong
Jakarta
Kuala Lumpur
Melbourne
Shanghai
Singapore
Taipei
EUROPE
NORTH
LATIN
AMERICA
NORTH
AMERICA
ASIA
PACIFICSOUTH EUROPE, MIDDLE
EAST, AFRICA & INDIA
Production facilities and officesRepresented on six continents - 9 manufacturing centers-of-excellence and
35 technical support and sales offices in 23 countries throughout the world
BogotaBuenos Aires
Mexico City
São Paulo
Copenhagen
Haddenham
Hannover
Moscow
Warwick
•••••