wireless energy meter art.no.: 36-4000 model: efergy … energy meter art.no.: 36-4000 model: efergy...
TRANSCRIPT
Wireless Energy MeterArt.no.: 36-4000Model: Efergy elite 2.0
Table of conTenTs
IntroductIon 3
Safety 4
PackagecontentS 5
fIndIngthePowerSuPPlycableforyourelectrIcItymeter(uk) 6
fIndIngthePowerSuPPlycableforyourelectrIcItymeter(Se)(no)(fIn) 8
InStallatIon 10
SynchronISIngthetranSmItteranddISPlayunIt 11
SettIngthetImeanddate 12
otherSettIngS 13
dualtarIff 15
dISPlayInformatIon 17
normaldISPlayofPreSentconSumPtIon 18
PrevIouSconSumPtIondISPlay 19
troubleShootIng 20
dISPoSal 22
SPecIfIcatIonS 22
3
InTroducTIon
themeasuringandmonitoringofenergyisthebasisforsavingenergy.youneedthisinformationinordertoknowwhereandhowyoucansavemoney.
efergyisanenergymeterwhichshowshowmuchenergyisconsumedinyourhomeatthetimeyoureadthedisplay.thedisplaycanalsogivetheuserinformationonconsumedenergycosts.youcanalsomovethereceiveraroundthehouseandturnonoroffanelectricaldevicetoseethedifferenceinpowerconsumptiondirectlyonthedisplay.
IfyouhaveanyquestionsregardingtechnicalproblemspleasecontactcustomerServices.
safeTy
ItISveryImPortantthatyoutakeIntoconSIderatIonafewSImPlePrecautIonarymeaSureSbeforeuSIngthISProduct
efergyenergymetersareeasytoinstall.Still,therearesomeessentialsafetyrulesthatyoumustbeconsciousof:• IntheukorIrelandtheinstallationoftheenergymeteriseasy,sincetheonlythingthatis
requiredistoconnectasensortotheincomingmainspowercable.Ifyoustillfeelunsureastohowtomountthesensor,werecommendthatyoucontactaqualifiedelectrician.
• IntheScandinaviancountriesa3-phasesystemisused,whichmeansthatonemustinstallallthreeincludedsensors.thesensorclampsshouldbeclampedovertheincomingelectricalcablesinoroutsidethedistributionbox.contactaqualifiedelectricianifyouunsureastohowtoinstallthesensors.
• readandfollowtheimportantinformationcontainedinthefollowingpages.rememberthattheenergymeter’ssensorsdonotneedtohavedirectelectricalcontactatthemeasuringpoint.thesensorsshouldsitaroundthecable.
• Ifyoufindsomethingunusualinoraroundthedistributionboxlikeloosecables,barecables,burnmarks,openingsintheinsulationjacketoranyotherdamage,etc.youmustimmediatelyquitworkingandcontactyourelectriccompanyorthepersonresponsibleforelectricalinstallations.
• thecablesmustnotbebentoroverloadedwhenmountingthesensors.
Ifyouareuneasyorhaveanyquestionsregardingthemountingoftheenergymeter'ssensors,contactaqualifiedelectricianimmediately.thesensorsdonotneedtoberemovedduringthelifetimeoftheequipment.however,batteriesneedtobechangedoccasionallyinthetransmitteranddisplayunit.thesensorsdonothaveanybatteriesthatneedtobechanged.
5
Sensor Transmitter
Display unit
Package conTenTs
3xSensors(currenttransformer)1xtransmitter1xdisplayunit(receiver)
youshouldclampthesensorsovertheincomingmainspowercablesleadingintothedistributionbox.allpowerconsumedinthehouseholdenterthroughthesecables.
theclip-onsensorsensesthecurrentwhichpassesthroughthesecables.areadingoftheamountofpassingcurrentisthenwirelesslysenttothedisplayunitviathetransmitter.theenergyconsumptionisshowndirectlyonthedisplay.
Diagram 2Diagram 1
fIndIng The Power suPPly cable for your elecTrIcITy meTer (uk)
theefergyenergymeterisinstalledbyclampingthesensorclipsaroundtheincomingmainspowercablesleadingtoyourelectricitymeter.
fIndIngyourelectrIcItymeter
findoutaboutyourelectricitymeterandcheckwhichtypeyouhave.Itisnormallyfoundonanouterwall,inthegarage,inthecellarorinautilityroom.Ifyouliveinaflat,itmaybelocatedneartheentrydoor,inthestairway,orinthecellar.makesurethecablesexitingthebottomoftheelectricitymeterareaccessible.
modernofficesandflatscanhavesafetypanelswhichprotectthecablesenteringtheelectricitymeter.Ifthisisyoursituation,werecommendthatyoucontactaqualifiedelectrician.
fIndIngthePowerSuPPlycable
therearefourcablesatthebottomoftheelectricitymeter.thecableontheright(cable4)isalwaysthelivefeedwire(activephase)fromthemetertothefusebox(sediagram1).
certaininstallationshavecables1and2entirelyorpar-tiallycoveredinordertohindermodificationorhomeinstallationofcablesbeforethemeter(seediagram2).connectthesensortocable4(onthefarright)meterswithdualtariffs(seediagram3)oftenhaveanextracablebetweencable3and4.theextracablehasasmallerdiameterthantheothercablesandleadstoanotherelectricitymetercloseby.
7
Diagram 3
Cable 4
Extra cable
newerinstallationsnormallyhavetwocablesontheundersideofthemeter.oneofthecablesistheearthcableandtheotheristhefeedcable.thesensorshouldbeclampedaroundthefeedcable(normallycolouredbrown).
Ifyouhavea3-phasesupplyorifyouhaveaneconomy7meteryouwillneedadditionalsensors.theextrasensorseasilyconnecttothesocketatthebaseofthetransmitter.n.b. theenergymetercomeswith3sensors.
Safety
youshouldundernocircumstancesconnectasensortoacableifanyofthecablesleadingtothemeterisdamagedinanyway.nocablesneedtobecut.donotclipanycables.donotbreakanysealsorsuchonthemeter.
contactyourlocalelectricitysupplierifyouareatalluncertainaboutconnectingthesensortothecorrectcable.
fIndIng The Power suPPly cable for your elecTrIcITy meTer (se) (no) (fIn)
theefergyenergymeterisinstalledbyclampingthesensorclipsaroundtheincomingmainspowercablesleadingtoyourelectricitymeter.
fIndIngyourelectrIcItymeter/dIStrIbutIonbox
findoutwhereyourmeterislocated.Itisnormallyfoundonanouterwall,inthegarage,inthecellarorinautilityroom.Ifyouliveinaflat,itmaybelocatedneartheentrydoor,inthestairway,orinthecellar.makesurethecablesexitingthebottomoftheelectricitymeterareaccessible.
modernhomesandflatscanhavesafetypanelswhichprotectthecablesenteringthemeter.theseareoftensealed.undernocircumstancesshouldthesealsbebrokenotherthanbyaqualifiedelectrician.Instead,werecommendthatthesensorsbeinstalledafterthemainswitchinyourdistributionbox.
Ifyoustillfeelunsureastohowtomountthesensor,werecommendthatyoucontactaqualifiedelectrician.
9
Sensor (3x)
Transmitter
Electricity meter
fIndIngthePowerSuPPlycable
InSweden,norwayandfinlandtherearefourfeedcablesenteringtheelectricitymeter:3livephases(l1,l2,l3)and1neutral(n),neutralisnormallyblueandthelivecablesareeitherblackorbrown.cablesl1–l2–l3areliveanditisthesethatthesensorsshouldbeattachedto.
Safety
youshouldundernocircumstancesconnectasensortoacableifanyofthecablesleadingtothemeterisdamagedinanyway.nocablesneedtobecut.donotclipanycables.donotbreakanysealsorsuchonthemeter.
contactyourlocalelectricalsupplierifyouareatalluncertainaboutconnectingthesensorstothecorrectcable.
InsTallaTIon
mountIngtheSenSorS
thesensorsshouldbeclampedontoone(uk)orthree(Se)(no)(fIn)livefeedphases.thesen-sorscanbeusedoncablesupto12mmindiameter.thesensormustnotbemountedwithforce.
1. findyourlivefeedcable(uk),cables(Se)(no)(fIn).2. Pressthereleasecapupwardstoopenthesensor.3. makesurethatyouhavethecorrectcableandplacethesensoraroundthecable.4. Pressthesensortogetherandaclickwillbeheardwhenthereleasecaplocks.5. mountasensorontherespectivelivefeedcablesl1,l2,l3(Se)(no)(fIn).
connecttheSenSortothetranSmItter
Plugthesensorsintothesocketsonthebottomofthetransmitter.thesensors/plugsdonothavetobeinanyparticularorder.thesensorsensesthecurrentwhichpassesthroughthesecables.areadingoftheamountofpassingcurrentiswirelesslysenttothedisplayunitviathetransmitter.theenergyconsumptionisshowndirectlyonthedisplay.
11
Link
synchronIsIng The TransmITTer and dIsPlay unIT
1. Startbyinsertingthreeaa/lr6batteriesintothetransmitter’sbatterycompartment,andthreeaa/lr6batteriesinthedisplayunit’sbat-terycompartment.Tip:Ifthetransmitterislocatedoutdoors,itisextraimportanttousegoodqualitybatteries.usealkalineorpreferablylithiumbatterieswhichtoleratecoldbetter.
2. Press[link]onthebacksideofthedisplayunit.thetransmittericon willflashforaminute.
3. Pressthebuttononthefrontofthetransmit-teroncewhilethetransmittericon flashes.waituntiltheiconstopsflashing.Tip:Ifsynchronisationissuccessful,thetransmissionicon willshowonthedisplay.– – –willshowonthedisplayifunsuccessful.
n.b.thepreinstalledupdateintervalissixseconds.thismeansthatthetransmittersendsupdateseverysixseconds.Itispossibletoadjustthisintervalto6,12or18secondsbydepressingthetransmissionbuttonfortwoseconds(theledcolourwillchange).• red=6s.• orange=12s.• green=18s.
Time Set
seTTIng The TIme and daTe
theenergymetermustbeprogrammedwiththecorrecttimeanddateinordertogiveaccurateinformation.Settingthetimeanddate:
SteP1
onthebackofthedisplaythereisasettingsbutton[timeset].depressthisbuttonfortwoseconds.thedatedisplaywillbegintoflash.
SteP2
Setthecorrectdateusingthe[bwd]and[fwd]buttons.Press[mode]toconfirmandtocontinueontosettingthemonth.repeatthisproceduretosettheyear.Press[mode]toconfirmandtocontinuewithsettingthetime.
SteP3
Setthecorrecthourusingthe[bwd]and[fwd]buttons.Press[mode]toconfirmandtocontinue.repeatthisproceduretosettheminutes.Press[history]toconfirmthesetting.
13
History BWD FWD Mode
History BWD FWD Mode
oTher seTTIngs
theenergymetermustbeprogrammedwiththecorrecttariffperkwhinordertogiveaccurateinformation.Settingthetariff(validonlyifyoudonothaveadualtariffmeter).
n.b. youmustbeinnormaldisplaymodebeforeadjustinganysettings.Press[history]therequirednumberoftimesuntilhistorynolongershowsinthedisplay.
activatingthesettingsmode:depress[mode]fortwoseconds.n.b.Ifnobuttonispushedfor20secondsthedisplaywillgobacktonormaldisplaymodewithoutsavinganychanges.
SteP1.voltage
depress[mode]fortwoseconds.230willflash(230vispreset).adjustthevoltageusing[bwd]and[fwd]ifyouhaveadifferentmainsvoltage.Press[mode]toconfirmandtocontinuetothecurrencysetting.
SteP2.currency
Setthecorrectcurrency(£,€,orkr)usingthe[bwd]and[fwd]buttons.Press[mode]toconfirmandtocontinuetothetariffsetting.
History BWD FWD Mode
History BWD FWD Mode
History BWD FWD Mode
SteP3.SIngletarIff
the symbolwillbeginflashing.Press[mode]toconfirmifyouuseasingletariff.refertosectionDual Tariffifyouhaveanelectricitymeterfordualtariffs.Tip: duringtheentireinstallationprocessyoumaypress[history]tosaveyoursettingsandreturntonormaldisplaymode.
SteP4.coStS
Setthecorrecttariffusingthe[bwd]and[fwd]buttons.Press[mode]toconfirmandcontinue.
SteP5.kgco2(kgcarbondIoxIdePerkwh)
thekgco2/kwhcanbeadjustedwiththe[bwd]and
[fwd]buttons.Press[mode]toconfirmandcontinueontosettingthealarm.
SteP6.alarm(hIgh-energyconSumPtIonalarm)
thepresetalarmvalueissetto5kw.Ifthealarmfeatureisactivatedandyouusemorethan5kwthealarmwillsoundandaredindicatorlampwilllightonthedisplayunit.thealarmactivationvaluecanbesetusingthe[bwd]and[fwd]buttons.Press[mode]toconfirm.Press[alarmon/off]onthebackofthedisplayunittoactivateordeactivatethealarm.Press[history]toexitthesettingsmode.
15
History BWD FWD Mode
History BWD FWD Mode
dual TarIff
Ifyouhaveanelecticmeterwithdualtariffs,youneedtoprogramtheenergymeterforthisfunction.
SteP1.actIvatIngdualtarIffS
depress[mode]fortwoseconds.thevalueforthesetvoltage(230)willbegintoflash.Press[mode]twotimestoopenthedualtariffsettingsmode. willflashonthedisplay.advanceto withthe[bwd]or[fwd]buttons.Press[mode]toconfirm. and
willbeginflashing.
SteP2.SettIngtheStart&StoPtImeSfortarIff1
Setthestarttimefortariff1withthe[bwd]or[fwd]buttons.firstsetthestarttimebysettingthehoursandpress[mode]toconfirm.continuesettingtheminutesusingthesameprocess.Press[mode]toconfirm.
isreplacedby onthedisplay.Setthestoptimefortariff1usingthesameprocess.
example:youareonaneconomy-7tarifffrom01.00to08.00.Setthe 01.00andthe
08.00.
Press[mode]toconfirm.thensetthecurrencyandtariffperkwhforbothtariffsforbothdayandnight.
History BWD FWD Mode
History BWD FWD Mode
SteP3.SettIngtarIff1
thepresetvaluewillbeginflashing.Setthepresenttariffperkwhwiththe[bwd]or[fwd]buttons.Press[mode]toconfirm.
SteP4.SettIngtarIff2
thepresetvalueof willbeginflashing.Setthepresenttariffperkwhwiththe[bwd]or[fwd]buttons.Press[mode]toconfirm.0.50(kgco
2/kwh)
willbeginflashingonthedisplay.
17
dIsPlay InformaTIon
theenergymeterdisplaysinformationonpresent,previousandaverageenergyconsumption.
PreSentaverageconSumPtIon
thedisplayshowsaverageconsumptioninkwh,costorcarbondioxideemissions*.Press[mode]toswitchbetweendisplayingkwh,tarifforkgco
2.
*amountofproducedkgco2usedfortheproductionoftheelectricityconsumed.
theamountofco2produceddependsonhowyourelectricalenergyisproducede.g.hydro-
electric-,wind-,coal-power,etc.Itisuptoyoutodetermineandsettheco2perkwhvalue.
(SeeOther Settings,Step5)
graPhIcdISPlay
onthebottomportionofthedisplayagraphicrepresentationforthecurrentdayandthepreviousday’senergyconsumptionisshown.
normal dIsPlay of PresenT consumPTIon
thefollowingisshownonthedisplay:1. transmissionstrengthicon
2. tariffperhourorpresentcon-sumption(changesettingswiththe[mode]button)
3. lowbatterywarning:transmitter displayunit
4. alarmactivated:
19
History BWD FWD Mode
PrevIous consumPTIon dIsPlay
• Press[history]todisplaypreviousconsumption.• Press[history]toswitchbetweendisplays.currentday’senergyconsumption–mostrecent
week–mostrecentmonth.• Switchbetweenday/monthwith[bwd]or[fwd]tocompareenergyconsumption.• Press[mode]toswitchbetweendisplayingkwh-tariff-amountco
2.
TroubleshooTIng/faQ
If I remove the battery, will I lose all my saved data?no,theinformationissavedintheinternalmemoryandisnotlostwhenthebatteryischanged.
how do I reset the display (erase all data and start over)?depress[history]and[mode/set]simultaneously.clrwillshowonthedisplay.n.b.Ifyouresettheenergymeterallinformationonpreviousconsumptioniserased.however,timeanddateinformationissavedinthememory.
what is the transmitter’s range?therangeisover40metresinanormalhome.the433mhzfrequencyisverysuitableforthispurpose.withgoodconditionsthesignalsareabletospanuptothreefloors.
The displayen shows – – –. what does it mean?movethedisplayunitclosertothetransmitterandpress[link].Iftheproblempersists,contactourcustomerServices.
why does the background light come on sometimes?thebackgroundlightistimercontrolledinordertosavethebattery.Itisonlyactivatedatnight.
The transmitter and the display unit (receiver) don’t seem to have contact with each other. what do I do?movethedisplayunitclosertothetransmitterandpress[link].Ifthisdoesn’thelp,trychangingthetransmitterbatteries.IftheproblempersistscontactourcustomerServices.
21
what does the graph stand for?thegraphonthebottomportionofthemeter’sdisplayrepresentskwh.themeasuredrangeofthegraphisfrom3kwhto21kwh.thismeansthatthebargraphwillnotdisplayanyaverageconsumptionreadingsbelow3kwh.thisalsomeansthatthebarsonthegraphwillallbefulliftheaveragedailyreadingisover21kwh.
what is the energy meter’s display capacity?Itcanmeasureupto999kwhinaweek
settings specific to norwegian electrical networks (IT-nett, Tn-nett)IT-net:thevalueshouldbesetto130v,(Itnetthas230vbetweenphases).Tn-net:thevalueshouldbesetto230v,(tn-nethas400vbetweenphases).how thick can the cables be that the sensors clamp onto?thesensorscanbeusedoncablesupto12mmindiameter.
what should the measurement voltage be set to in each respective country?ISweden,finlandandtheukthemeasurementvoltageshouldbesetto230v.Innorwaythemeasurementvoltageshouldbesetto:130v(It-net)or230v(tn-net).
dIsPosal
followlocalordinanceswhendisposingofthisproduct.Ifyouareunsureofhowtodisposeofthisproduct,pleasecontactyourmunicipality.
sPecIfIcaTIons
model: efergyelite2.0
frequency: 433mhz
transmissionintervals: 6–12–18seconds
range: 70metres
measuringvoltage: 110–400v
measuringcurrent: 50ma–95a
accuracy: >90%
backlight: activatedbetween18:00and06:00
Powersupply: adaptor5v,100ma(notincluded).
declaratIonofconformIty
hereby,clasohlsonab,declaresthatfollowingproduct(s):
Wireless Power Meter36-4000 Elite, WPM100
isincompliancewiththeessentialrequirementsandotherrelevantprovisionsofdirective1999/5/ec.
article3.1a(Safety): en60950-1article3.1b(emc): en55022 en55024 en301489-1 en301489-3
article3.2(radio): en300220-1 en300220-2
Insjön,Sweden,november2009
klasbalkow
President
clasohlson,79385Insjön,Sweden
sverIge
kundtJÄnSt tel:0247/44500 fax:0247/44509 e-post:[email protected] www.clasohlson.sebrev clasohlsonab,79385InSJÖn
norge
kundeSenter tlf.:23214000 faks:23214080 e-post:[email protected] www.clasohlson.noPoSt clasohlsonaS,Postboks485Sentrum,0105oSlo
suomI
aSIakaSPalveluPuh.:0201112222 Sähköposti:[email protected] www.clasohlson.fioSoIte clasohlsonoy,annankatu34–36a,00100helSInkI
greaT brITaIn
forconsumercontact,pleasevisit www.clasohlson.co.uk andclickon customer service.Internet www.clasohlson.co.uk