wireless blood glucose monitoring system front view 93 · bayer healthcare contour next link n2.1...

2
Enter this Meter ID Enter this Meter ID into your pump: into your pump: 123456 123456 ? OK OK Go Back Go Back CONNECT TO PUMP CONNECT TO PUMP Automatically send results to the Pump? Ask me Ask me Never Never SEND OPTIONS SEND OPTIONS METER ID MENU Add ID Delete ID Review ID REVIEW METER ID 1. 123456 2. ------ 3. ------ 10/10/10 10/10/10 10:30 AM 10:30 AM Accept Accept Change Change CURRENT DATE & TIME CURRENT DATE & TIME CONNECT TO PUMP CONNECT TO PUMP CONNECT TO PUMP CONNECT TO PUMP ? OK OK Go Back Go Back ? OK OK Go Back Go Back Connect to a Medtronic Pump? Enter this Meter ID into your Pump: 123456 70–130 70–130 70–180 70–180 ? Accept Accept Change Change CURRENT TARGET CURRENT TARGET HIGH AND LOW LIMITS HIGH AND LOW LIMITS ? Accept Accept Change Change High: 250 High: 250 mg/dL mg/dL Low: 70 Low: 70 mg/dL mg/dL OK OK Initial Setup is complete. Initial Setup is complete. OK ® QUICK REFERENCE GUIDE ® ® 93 mg dL Before Meal Before Meal 01:33PM l 11/10 01:33PM l 11/10 Reminder Reminder Notes Notes Uses only CONTOUR ® NEXT Blood Glucose Test Strips from Bayer 11 To add a new meter, select Add ID and press ACT. Refer to Step 5 (or see meter back) to find meter ID. Use the up and down arrow buttons to enter the six character meter ID shown on the meter screen. Press ACT after each character entry. NOTE: High and Low Limits can only be set outside your selected Target range(s). Targets can only be set inside your selected High and Low Limit(s). For additional information, you may contact Customer Service at 800-348-8100, available 24 hours a day, 7 days a week. Initial Setup of the Meter and Connection to Compatible Medtronic MiniMed ® Device 1 Remove the cap with the on it to reveal the USB connector. The CONTOUR ® NEXT LINK meter from Bayer has a permanent rechargeable battery. Before you do anything else, charge your meter with the wall charger included with your kit or by plugging the USB connector into a computer. Be sure the computer is turned on. Your meter will briefly display “Do Not Test–Charging” and the test strip port light will flash. You cannot do a blood glucose test while the battery is charging. When charging is finished, the test strip port light will turn off. Unplug your CONTOUR NEXT LINK meter to test. 2 To begin setup, hold down Menu button for several seconds until the meter turns on. 3 Choose your language and press OK. 4 Press OK on the next screen to begin the connection process. NOTE: Pump refers to your compatible Medtronic MiniMed device. 5 STOP. Do NOT press ANY buttons. This screen displays the meter ID number (in the bottom left corner). This ID is needed to complete the connection process. Put down your meter. Pick up the compatible Medtronic MiniMed device and continue with Step 6. 6 Press ACT to go to the MAIN MENU of your compatible Medtronic MiniMed device. Scroll to Utilities by pressing the down arrow. Press ACT. 7 If you are using the Paradigm ® REAL-Time Insulin Pump, scroll to Meter Options from the UTILITIES MENU and press ACT. If you are using the Guardian ® REAL-Time Monitor, refer to the user guide for connecting your meter. 8 Select On and press ACT. If you are replacing a meter, go to Step 9. If you are adding a new meter, go to Step 11. 9 If replacing a meter, select Delete ID and press ACT. 10 If you have multiple meter IDs, repeat Step 9 for each one. 13 Return to your CONTOUR NEXT LINK meter. After you have entered the meter ID into your compatible Medtronic MiniMed device, press OK. 12 Select Review ID on your compatible Medtronic MiniMed device to confirm that your CONTOUR ® NEXT LINK meter ID has been correctly entered. If incorrect, go back to Step 9. NOTE: For detailed instructions, see your compatible Medtronic MiniMed device user guide. 14 SEND OPTIONS controls how your meter will send blood glucose readings to your compatible Medtronic MiniMed device. Choose the SEND OPTION that is best for you. Ask Me = Meter will ask you before sending results. Never = Meter will never send results. 16 Choose your AUTOLOG settings. AUTOLOG allows you to mark a test as Before Meal, After Meal or No Mark. 17 The meter comes preset with the default blood glucose target ranges as shown. Accept the default blood glucose target ranges or Change them after talking to your health care professional. 18 Follow the display prompts to set your meter High and Low Limits. Choose Accept to use the default setting (250 mg/dL for the meter high limit and 70 mg/dL for the meter low limit). Choose Change if you wish to use different limits. Connecting Meter to Compatible Medtronic MiniMed Devices Choosing Meter Send Options Set Meter Date/Time to Match Medtronic Device Additional Meter Settings SETUP IS NOW COMPLETE! Setting Up the Meter  ? = Help MAIN MENU Basal Prime Utilities UTILITIES MENU Alarm Clock Meter Options Remote Options METER OPTION Off On METER ID MENU Add ID Delete ID Review ID METER ID MENU Add ID Delete ID Review DELETE METER ID 1. aaaaaa 2. bbbbbb 3. ------ ADD METER ID 123456 STAT STAT STAT STA STA ST ST STAT STA US US US US U100 U100 U100 1 U100 0 00 00 Batt Batt t Batt Batt t ery: ery: ery r ery: Nor Nor r r Nor r Nor N r r r r rmal mal mal mal l l l S/N# S/N# S/N# N S/N# S/N# S/N# N N# N# N N N S/N# N 454 454 454 454 454 454 454 454 454 4 4 4 4 40 056 056 056 5 056 056 056 5 056 05 056 USB Connector Charging the Meter 15 The date and time on your meter must match the date and time on your Medtronic device. Pick up Medtronic device. Press ACT to go to the MAIN MENU. Scroll to Utilities and press ACT. Scroll to Time/Date and press ACT. Select a time format and press ACT. Note the time and date. Return to your meter. Follow instructions on your meter to change the time and date to match your Medtronic device. 10:30 10:30 AM A A A M Mon n n n 10 OCT 2 2 2 2 2 2 2 C 0 0 010 0 TOP VIEW Selection/ Scrolling Buttons Test Strip Port Display Screen Top Menu Button Protective USB Cap Note: Check the units of measure of your meter. See your meter user guide for complete instructions. FRONT VIEW 81548021 Rev. 04/13 Wireless Blood Glucose Monitoring System 12:24 PM METER BG Mg/dL 93 10:30 AM l 3/11 10:30 AM l 3/11 Reminder Reminder Notes Notes 93 mg dL Before Meal English Espanol LANGUAGE LANGUAGE ? Accept Accept Turn Off Turn Off AUTOLOG AUTOLOG AutoLog is on.

Upload: others

Post on 06-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Wireless Blood Glucose Monitoring System FRONT VIEW 93 · Bayer HealthCare Contour Next LINK N2.1 QRG English 911031 9624, 6201 9624-83623013 6201-83623021 ... Unplug your CONTOUR

DATE:CLIENT:

DESCRIPTION:SCHAWK JOB#:

SKU#:PARENT BAN#:DIMENSIONS:

PRINTER SPEC:

RELEASE: V-1 LANGUAGE(S): ENGLISHINTERNAL: R-X

18211 NE 68th Street, E120 Redmond, WA 98052 T: 425-881-5454

BAN#:81548021 Rev. 04/13Contour Next LINK N2.1 QRG - USAlt#1 - 05/07/13 copy changes

May 07, 2013Bayer HealthCareContour Next LINK N2.1 QRG English9110319624, 62019624-83623013 6201-8362302116.5" (H) x 8.0" (W)10000010027 REV-

FONTS: Helvetica, Helvetica Neue, Zapf Dingbats, Arial, Skinny Mini, Mini Micra, COLORS: Cyan Magenta Yellow Black

NOTE: THIS COLOR PROOF INDICATES COLOR BREAK ONLY AND MAY NOT ACCURATELY REFLECT ACTUAL PRODUCTION COLOR.Regional Master Template No: XXXXClinical Trial / Global Master Template No: M-QRG-0230_R0002

Enter this Meter IDEnter this Meter IDinto your pump:into your pump:123456123456

?

OKOK

Go BackGo Back

CONNECT TO PUMPCONNECT TO PUMP

Automatically sendresults to the Pump? Ask meAsk me

NeverNever

SEND OPTIONSSEND OPTIONS

METER ID MENUAdd IDDelete IDReview ID

REVIEW METER ID1. 1234562. ------3. ------

10/10/1010/10/10

10:30 AM10:30 AMAcceptAccept

ChangeChange

CURRENT DATE & TIMECURRENT DATE & TIME

CONNECT TO PUMPCONNECT TO PUMP

CONNECT TO PUMPCONNECT TO PUMP

?

OKOK

Go BackGo Back

?

OKOK

Go BackGo Back

Connect to a Medtronic Pump?

Enter this Meter IDinto your Pump:123456

70–130 70–130

70–180 70–180

?

AcceptAccept

ChangeChange

CURRENT TARGETCURRENT TARGET

HIGH AND LOW LIMITSHIGH AND LOW LIMITS ?AcceptAccept

ChangeChange

High: 250 High: 250 mg/dLmg/dL

Low: 70 Low: 70 mg/dLmg/dL

OKOK

Initial Setup is complete.Initial Setup is complete.

OK

®

QUICK REFERENCE GUIDE

®®

93 mgdL Before Meal

Before Meal

01:33PM l 11/10

01:33PM l 11/10

ReminderReminderNotesNotes

Uses only CONTOUR®NEXT Blood Glucose Test Strips from Bayer

11 To add a new meter, select Add ID and press ACT. Refer to Step 5 (or see meter back) to find meter ID.

Use the up and down arrow buttons to enter the six character meter ID shown on the meter screen.

Press ACT after each character entry.

NOTE: High and Low Limits can only be set outside your selected Target range(s). Targets can only be set inside your selected High and Low Limit(s). For additional information, you may contact Customer Service at 800-348-8100, available 24 hours a day, 7 days a week.

Initial Setup of the Meter and Connection to Compatible Medtronic MiniMed® Device

1 Remove the cap with the on it to reveal the USB connector.

The CONTOUR®NEXT LINK meter from Bayer has a permanent rechargeable battery. Before you do anything else, charge your meter with the wall charger included with your kit or by plugging the USB connector into a computer. Be sure the computer is turned on. Your meter will briefly display “Do Not Test–Charging” and the test strip port light will flash.

You cannot do a blood glucose test while the battery is charging. When charging is finished, the test strip port light will turn off. Unplug your CONTOUR NEXT LINK meter to test.

2 To begin setup, hold down Menu button for several seconds until the meter turns on.

3 Choose your language and press OK.

4 Press OK on the next screen to begin the connection process.

NOTE: Pump refers to your compatible Medtronic MiniMed device.

5 STOP. Do NOT press ANY buttons.

This screen displays the meter ID number (in the bottom left corner). This ID is needed to complete the connection process.

Put down your meter. Pick up the compatible Medtronic MiniMed device and continue with Step 6.

6 Press ACT to go to the MAIN MENU of your compatible Medtronic MiniMed device. Scroll to Utilities by pressing the down arrow. Press ACT.

7 If you are using the Paradigm® REAL-Time Insulin Pump, scroll to Meter Options from the UTILITIES MENU and press ACT.

If you are using the Guardian® REAL-Time Monitor, refer to the user guide for connecting your meter.

8 Select On and press ACT. If you are replacing a meter, go to Step 9. If you are adding a new meter, go to Step 11.

9 If replacing a meter, select Delete ID and press ACT.

10 If you have multiple meter IDs, repeat Step 9 for each one.

13 Return to your CONTOUR NEXT LINK meter. After you have entered the meter ID into your compatible Medtronic MiniMed device, press OK.

12 Select Review ID on your compatible Medtronic MiniMed device to confirm that your CONTOUR®NEXT LINK meter ID has been correctly entered. If incorrect, go back to Step 9.

NOTE: For detailed instructions, see your compatible Medtronic MiniMed device user guide.

14 SEND OPTIONS controls how your meter will send blood glucose readings to your compatible Medtronic MiniMed device.

Choose the SEND OPTION that is best for you. Ask Me = Meter will ask you before sending results.

Never = Meter will never send results.

16 Choose your AUTOLOG settings. AUTOLOG allows you to mark a test as

Before Meal, After Meal or No Mark.

17 The meter comes preset with the default blood glucose target ranges as shown. Accept the default blood glucose target ranges or Change them after talking to your health care professional.

18 Follow the display prompts to set your meter High and Low Limits. Choose Accept to use the default setting (250 mg/dL for the meter high limit and 70 mg/dL for the meter low limit). Choose Change if you wish to use different limits.

Connecting Meter to Compatible Medtronic MiniMed Devices

Choosing Meter Send Options

Set Meter Date/Time to Match Medtronic Device

Additional Meter Settings

SETUP IS NOW COMPLETE!

Setting Up the Meter

  ? = Help

MAIN MENUBasalPrimeUtilities

UTILITIES MENUAlarm ClockMeter OptionsRemote Options

METER OPTIONOffOn

METER ID MENUAdd IDDelete IDReview ID

METER ID MENUAdd IDDelete IDReview

DELETE METER ID1. aaaaaa2. bbbbbb3. ------

ADD METER ID

1 2 3 4 5 6

STATSTATSTATSTASTASTSTSTATSTA US US USUS U100U100U1001U10000000BattBatttBattBattt ery:ery:eryrery: NorNorrrNorrNorN rrrrrmalmalmalmallll

S/N#S/N#S/N#NS/N#S/N#S/N#NN#N#NNNS/N#N 4544544544544544544544544544 444400560560565056056056505605056

USB Connector

Charging the Meter

15 The date and time on your meter must match the date and time on your Medtronic device.

Pick up Medtronic device.

Press ACT to go to the MAIN MENU. Scroll to Utilities and press ACT. Scroll to Time/Date and press ACT. Select a time format and press ACT. Note the time and date.

Return to your meter. Follow instructions on your meter to change the time and date to match your Medtronic device.

10:3010:30AMAAAA

MMon n nn 10 OCT 2222222C 000100

TOP VIEW

Selection/Scrolling Buttons

Test Strip Port

Display Screen

Top Menu Button

Protective USB Cap

Note: Check the units of measure of your meter.See your meter user guide for complete instructions.

FRONT VIEW

8154

8021

R

ev. 0

4/13

Wireless Blood Glucose Monitoring System

12:24 PMMETER BG

Mg/dL93

10:30 AM l 3/1110:30 AM l 3/11

ReminderReminder

NotesNotes93 mg

dL

Before Meal

EnglishEspanol

LANGUAGELANGUAGE

?

AcceptAccept

Turn OffTurn Off

AUTOLOGAUTOLOG

AutoLog is on.

81548021_CntrNextLINK_N2_1_ENna_FpBp_v1 05/07/13 8:36 AM

FC: 13mm BC: 11.5mmFooter: N/A 1/3rd of the Cross clear space has been applied.7mm min.

May 9, 2013

Page 2: Wireless Blood Glucose Monitoring System FRONT VIEW 93 · Bayer HealthCare Contour Next LINK N2.1 QRG English 911031 9624, 6201 9624-83623013 6201-83623021 ... Unplug your CONTOUR

WARNING:• The meter, lancing device and lancets are for single patient use. Do not share them with anyone including

other family members. Do not use on multiple persons.1,2

• All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you have performed cleaning and disinfection.

• Always wash your hands well with soap and water before and after testing, handling the meter, lancing device, or test strips.

For complete instructions on cleaning and disinfecting your meter and lancing device, please see your meter user guide.

References1 FDA Public Health Notification: Use of Fingerstick

Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens: Initial Communication (2010).http://www.fda.gov/MedicalDevices/Safety/AlertsandNotices/ucm224025.htm

2 CDC Clinical Reminder: Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Bloodborne Pathogens (2010).http://www.cdc.gov/injectionsafety/Fingerstick-DevicesBGM.html

93 mgdL

Sent, Sent, Before... Before...

10:30AM l 11/1010:30AM l 11/10

93 mgdL

Sent, Sent, Before... Before...

RESULTS SENTRESULTS SENT

ReminderReminder

NotesNotes

AUTOLOG AUTOLOG Before Meal Before Meal

After Meal After Meal

No MarkNo Mark

OK

2 Remove lancing device endcap.

Insert lancet into lancing device and twist off protective cap.

1 Insert test strip and wait for APPLY BLOOD message.

3 Re-cap and dial to desired lancing depth.

4 Obtain your blood drop.

5 Touch the tip of the test strip to the drop of blood.

If the first blood drop is not enough, the meter will beep twice and display STRIP UNDERFILLED. You have about 30 seconds to apply more blood to the same strip.

8 Select Reminder to set a reminder for your next test. Select Notes to add more information to the result. Remove test strip.

9 Remove the test strip and the meter will turn off in 3 minutes. Or hold down the Menu button to turn off the meter.

Obtaining the Blood Drop

Testing the Blood Drop

Sending Results to Your Compatible Medtronic MiniMed Device

Reminder and Notes

Turn Meter Off

See your CONTOUR®NEXT LINK user guide, MICROLET®2 insert and compatible Medtronic MiniMed device user guide for full instructions.

Call 800-348-8100 (available 24 hours a day, 7 days a week) with any questions

or visit www.bayerdiabetes.com/usFor In Vitro Diagnostic Use

Bayer, the Bayer Cross, CONTOUR, MICROLET and the No Coding logo are registered trademarks of Bayer. All other trademarks are the property of their respective owners.

© 2013 Bayer. All rights reserved.

8154

8021

R

ev. 0

4/13

Bayer HealthCare LLCMishawaka, IN 46544 USA

7 If Ask Me was selected in Send Options during Setup, results can be sent to your compatible Medtronic MiniMed device. Press OK to move to the next screen.

6 If AUTOLOG is on, you can choose to record your result as: Before Meal, After Meal or No Mark for the test result.

Testing Your Blood

Materials for Testing

MICROLET®2 Lancing Device from Bayer

CONTOUR®NEXTTest Strip from Bayer

MICROLET® Lancet from Bayer

CONTOUR®NEXT LINK Blood Glucose Meter from Bayer

81548021_CntrNextLINK_N2_1_ENna_FpBp_v1 05/07/13 8:36 AM