winterisation and tropicalisation systems - start the interests of continued development,...

32

Upload: lyhuong

Post on 24-Apr-2018

217 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical
Page 3: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical
Page 4: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical
Page 5: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical
Page 6: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• • • •

* Petrol Variant is available upon request—Please refer to Webasto Engineering for Technical Specification

Technical Data

Rated Voltage v 12 or 24

Rated Heat Output Full Heat

Mid-Range Reduced Heat

kW 2.0

Fully Variable 0.9

Fuel Consumption Full Heat Reduced Heat

Ltrs/hr 0.24 0.12

Maximum Heated Airflow m3/hr against 0.5mb 70

Fuel

Noise Level Full Heat Reduced Heat

dB(A) 56 48

Electrical Input

Start Up Full Heat

Reduced Heat

W

80 22

Fully Variable 9

Dimensions of Heater L x B x H mm 490 x 180 x 185

Weight of Heater kg 7

Diesel*

Page 7: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• • • • • ••

Technical Data

Rated Voltage v 12 or 24

Rated Heat Output Full Heat

Mid-Range Reduced Heat

kW 3.5

Fully Variable 1.5

Fuel Consumption Full Heat

Mid-Range Reduced Heat

Ltrs/hr 0.42

Variable 0.17

Airflow m3/hr 139

Fuel

Noise Level Full Heat

Mid-Range Reduced Heat

dB(A) 55

Variable 41

Electrical Input

Start Up Full Heat

Mid-Range Reduced Heat

W

80 36

Variable 15

Dimensions of Heater L x B X H mm 555 x 195 x 220

Weight of Heater kg 11.7

Diesel

Page 8: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• • • • •

Technical Data

Rated Voltage v 12 or 24

Rated Heat Output

*Boost Full Heat

Mid-Range Reduced Heat

kW

5.5 5.0

Fully Variable 1.5

Fuel Consumption

*Boost Full Heat

Mid-Range Reduced Heat

Ltrs/hr

0.66 0.60

Variable 0.17

Airflow m3/hr 218

Fuel

Noise Level Full Heat

Mid-Range Reduced Heat

dB(A) 61

Variable 41

Electrical Input

Start Up *Boost

Full Heat Mid-Range

Reduced Heat

W

80 90 80

Variable 15

Dimensions of Heater L X B X H mm 555 x 195 x 220

Weight of Heater kg 11.7

Diesel

Page 9: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

••

• •

Rated Voltage v 12 24

Rated Heat Output Full Heat Reduced Heat

kW 9.0 6.5

Fuel Consumption Full Heat Reduced Heat

Ltrs/hr

Heated Airflow Full Heat Reduced Heat

m3/hr 280 195

310 215

Fuel Diesel Only

Electrical Input Full Heat Reduced Heat

W 110 80

160 95

Dimensions of Heater l x b x h mm 650 x 300 x 375

Weight of Heater inc control unit & fuel pump

kg 21.60

1.2 0.86

Page 10: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• •

• • •

Rated Voltage v 24

Rated Heat Output Full Heat Reduced Heat

kW 5.0 2.2

Fuel Consumption Full Heat

Reduced Heat Ltrs/hr 0.63 0.27

Power Consumption Full Heat

Reduced Heat W

Dimensions of Heater l x b x h mm 380 x 180 x 200

Weight of Heater inc enclosure & fuel pump kg 10

50 34

Fuel Type Diesel

Page 11: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

Product benefits:

■ Pressurised combustion chamber allows forexhaust lengths up to 5m

■ The most compact heater in it’s class■ Variable heat output increases the range

of applications■ Integrated diagnostic capability■ Unique “Ferrotec” Burner technology■ AVTUR Compatible■ Ceramic Glowpin Technology

Application proven to:

■ EMC MIL-STD-461E for Ground Army■ Environmental Conditions -46°C according

STANAG 2895■ Shock Stress according DIN EN 60068-2-27■ Salt Spray resistance according to ISO 9227:2006■ Wading capability up to 1m submersion■ Fuel Compatibility F34, F44, AVTUR FS2-C Cat 2■ DefStan 59-41 Class A—DRE 03■ DefStan 59-41 for Ripple, Surges and Spikes

Typical Application:

■ Winterisation supporting engine, crew or auxiliaryequipment heating for Heavy Tactical Vehicles

Thermo 90 ST MIL

Operation Thermo 90 ST

Heat Output (kW) (part load/full load) Booster settingControl range

9.11.8 – 7.6

Fuel Diesel, AVTUR FS2-C Cat 2, F34, F44

Fuel Consumption (l/h) Booster settingControl range

1.10.19-0.9

Rated voltage (V) 24

Rated power consumption withwater pump (W)

Booster settingControl range

9037-83

Dimensions of heater (L x W x H) (mm)without control unit 310 x 133 x 235

Dimensions of control unit (L x B x H) (mm) 90 x 122 x 163

Weight (kg) 5.5

Iden

tN

r.M

K10

277

•10

/07

•A

llrig

hts

tom

odifi

catio

nsan

dco

rrec

tions

rese

rved

•Pr

inte

din

Ger

man

y•

©W

ebas

toA

G,G

CS

2007

•W

ebas

to’s

netw

orki

ngpa

rtne

ris

Cis

co

Technical specifications:

Page 12: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• •

• •

Volume Flow 4,800 l/h against 2 bar

Nominal Voltage 24v

Dimensions (l x b x h) 218 x 106 x 106 cm

Weight 3.3 kg

Nominal Power Consumption 140W

Page 13: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he

inte

rest

s o

f co

nti

nu

ed d

evelo

pm

ent,

sp

ecif

icat

ions

may c

hang

e fr

om

tim

e to

tim

e w

itho

ut

pri

or

no

tice

.

Page 14: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• • • •

Rated Voltage v 24

Rated Heat Output kW 5.0

Maximum Heated Airflow m3/hr 260

Dimensions of Heater mm 232 x 220 x 160

Page 15: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

Product benefits:

� Pressurised combustion chamber allows forexhaust lengths up to 5m

� The most compact heater in it’s class� Variable heat output increases the range

of applications� Integrated diagnostic capability� Unique “Ferrotec” Burner technology� AVTUR Compatible� Ceramic Glowpin Technology

Application proven to:

� DefStan 59-41 Class A—DRE 03� DefStan 59-41 for Ripple, Surges and Spikes

Typical Applications:

� Winterisation supporting engine, crew or auxiliaryequipment heating for Heavy Tactical Vehicles

DBW 2020_q7.qxd:_ 26.11.2007 14:19 Uhr Seite 1

Technical specifications:

DBW 2020.21

Heat flow (kW) 24

Fuel diesel fuel DIN 51601; fuel oil EL DIN 51603

Fuel consumption (kg/h) / (l/h) 2,5 / (3,0)

Nominal voltage (V) 12 or 24

Operating voltage (V) 10 - 14 or 20 - 28

Current consumption without Circulating pump (W) 90

Ambient temperature in Use: (°C ) – 40 - + 60

Storage temperature: (°C ) – 40 - + 85

Measurements heater inkl. control-unit (tolerance ± 3 mm):length (mm)breadth (mm)height (mm)

681230279

Weight (kg) 24

Page 16: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical
U9
Textfeld
Shelter Air Conditioning
Page 20: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

It’s all a question about the right climate: whether you’restuck in a traffic jam, waiting at the border or sleeping atnight. High temperatures inside the truck-driver’s com-partment often turn breaks during night and day intostressful situations. The NiteCool TCC-100 evaporativecooler, which is the flatest of its kind, provides comforta-ble interior temperatures without the engine running.

The unit which has a total height of only 125 mm is also equipped with a spoiler to prevent bothering windnoises whilst driving. In addition, the system is quiet inoperation and provides optimised sleeping comfort evenwhen outside temperatures are high.

The evaporative cooler boosts your well-being even during travel, provides alertness and prevents driver fatigue.

The NiteCool TCC-100 operates on the very efficientEvaporator principle and works without any compressoror refrigerant. Thanks to the exclusive Pre-CoolingChamber principle, the system achieves better coolingperformance than standard evaporator units.

The advantages of the NiteCool TCC-100evaporative cooler:

■ Cooling without idling■ No fuel consumption■ Very low height■ More powerful cooling thanks to pre-cooling

chamber principle■ Easy and quick to install■ Comfortable operation via remote control

or integrated control panel

■ Low noise operation■ Low-maintenance■ Electronic control of water level■ Programmable timing■ Environmentally friendly■ Can be retrofitted in virtually all vehicles

Cooling without idling – NiteCool TCC-100 evaporative cooler

Truck Evaporative Cooler

NiteCool TCC-100The evaporative cooler also cools while the engine is switchedoff which is ideal for breaks, during nights, in traffic jams andlong waiting periods.

NiteCool TCC-100 remote controlAll main functions can comfortably be controlled via remote control.

Page 21: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

Defence Market Air Conditioning

Typical Applications • Military Vehicles • Military Construction Equipment • Crew Cooling • Electronic & Communication Equipment Cooling

Technical Data:

Climate Tested to A1 Diurnal Cycle Climate Tested and Approved @ +49°C with 1,120 watts solar load EMC Tested to Def Stan 59-41 Class A for Land Vehicles EMC Compatibility with "Bowman" and "Locksmith"

Physical Data:

Condenser: (L) 800mm x (W) 170.5mm x (H) 350mm Weight = 18kg Evaporator: (L) 546mm x (W) 407.5mm x (H) 210mm Weight = 14kg

Electrical Data:

System: Voltage = 24 volt Current consumption = 13 A at 24v Condenser: Current consumption = 7 A Evaporator: Current consumption = 4 A

Cooling Capacity: 6.5kW

Advantages • Ease of Installation

• Suitable for OE and Retrofit Installation

• Designed and tested to Defence Standards

• Robust Construction

• Assists Cab Demisting

Webasto Product UK Limited Webasto House White Rose Way Doncaster Carr South Yorkshire United Kingdom DN4 5JH Phone : +44 (0) 1302 322232 Fax : +44 (0) 1302 322231 E-Mail: [email protected] Co Reg No : 2191825 VAT Reg No : 504 2738 67

6.5kW Split Module Air Conditioner

(Dimensional drawings overleaf)

Page 22: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

This Webasto compact roof-mounted air conditioning

system can be easily installed in any 24 Volt vehicle electrical

system, making it the perfect choice for On-Highway

vehicles, agriculture-, and construction cabins.

Product benefits:

� Powerful and very quiet air conditioning system� Easy to install� No installation of refrigerant hoses necessary� Constant optimum cooling performance,

irrespective of engine speed� Compressor driven by 24 Volt electric motor� Available as a compact or split unit� Easy to service� Pre-filled with refrigerant� Option: Electronic thermostat� Option: Compressors and electric motor also

available as a separate unit, in combination withthe Compact Cooler CC5

Compact Cooler CC 4E

The compact roof-mounted air conditioningsystem for On-Highway vehicles, Agriculture-,and Construction cabins.

SPMAir Conditioning Systems

Compact Cooler CC 4E

CompactCooler_CC4E_q7.qxd:_ 23.11.2007 19:40 Uhr Seite 1

Air flow principle

Air distribution panel

Technical specifications:

CC 4E

Voltage (V) 24

Max. totoal power consumption (A) 68 (24 V)

Dimensions L x W x H 1,110 x 774 x 215

Cooling capacity (kW) 3.5

Weight (kg) 55

Refrigerant (CFC-free) R 134 A

Air output free blow (m3/h) 550

Page 23: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

Cooling Capacity 3kW

Evaporator Fan, 3 speed volume flow (free blowing) Step One Step Two Step Three

TBC TBC TBC

Dimensions 660 x 580 X 410 mm

Weight 57kg

Nominal Voltage 24v

Refrigerant R134A (CFC Free)

Page 24: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• Suitable for Vehicles where Engine Driven

Cooling Capacity 3kW

Evaporator Fan, 3 speed volume flow (free blowing) Step One Step Two Step Three

TBC TBC TBC

Weight 50kg

Nominal Voltage 24v

Power Consumption 60A

Refrigerant R134A (CFC Free)

Page 25: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

Cooling Capacity 5kW

Evaporator Fan, 3 speed volume flow (free blowing) Step One Step Two Step Three

360m3/h 520m3/h 630m3/h

Dimensions (l x w x h) 750 x 760 x 165mm

Weight 26.5kg

Nominal Voltage 12 or 24v

Refrigerant R134A (CFC Free)

Page 26: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

Cooling Capacity 6kW

Heating Capacity 8kW

Fan Speed Step One Step Two Step Three

600m3/h 800m3/h 1100m3/h

Dimensions (l x w x h) 600 x 470 x 300

Weight 44kg

Nominal Voltage 24v

Refrigerant R134A (CFC Free)

Page 27: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

In t

he in

tere

sts

of c

ontin

ued

deve

lopm

ent,

spe

cific

atio

ns m

ay c

hang

e fr

om t

ime

to t

ime

with

out

prio

r no

tice.

• • •

•• • • • • •

Cooling Capacity 7kW

Evaporator Fan, volume flow (free blowing) 1100m3/h ± 15%

Dimensions (l x w x h) 1050 x 770 x 370 mm

Weight 45kg

Nominal Voltage 24v

Power Consumption 40A

Maximum working pressure 28.0 bar

Charge 2.0kg

Refrigerant R134A (CFC Free)

Page 28: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

SPM Breeze WP6 air-conditioner

Technical data

Webasto Petemar Sp. z o.o. ul. Warszawska 205/219 05-092 Łomianki www.webasto.pl Poland Tel : +48 (022) 732 732 0 Fax : +48 (022) 732 732 1 E-Mail: [email protected]

Breeze WP6 Shelter Air Conditioner

Cooling capacity: 6 kW

Refrigerant: R134a

Voltage input: 230 V AC (+10%, -15%) 50 Hz (2 Hz) 400 V version available on request

Starting current: 31 A

Nominal current: 4,4 A

Total weight: 82 kg

Page 29: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

Webasto Petemar Sp. z o.o. ul. Warszawska 205/219 05-092 Łomianki www.webasto.pl Poland Tel : +48 (022) 732 732 0 Fax : +48 (022) 732 732 1 E-Mail: [email protected]

BRYZA WP6 -TECHNICAL DATA

Electrical data Max. power consumption* 1560 W Compressor voltage 230 V AC (+10%, -10%) Condenser voltage 230 V AC (+10%, -15%) Evaporator voltage 230 V AC (+10%, -15%) Nominal frequency 50 Hz (±2 Hz) Current consumption - compressor (work) 3,4 A - compressor (start) 30 A - condenser 0,6 A - evaporator 0,34 A General technical data Max. Cooling capacity* 6 kW Evaporator airflow* min 350 m3

Condenser airflow min 3600 m3

Refrigerant R134a Refrigerant quantity* 850 g Compressor oil ester Oil quantity* 0,6 l Weight - compressor 42 kg - condenser 26 kg - evaporator 14 kg Dimensions - compressor 364 x 257 x 232 (W x H x D) - condenser 825 x 513 x 290 (W x H x D) - evaporator 858 x 170 x 455 (W x H x D) Working conditions Operating temperature from +20°C to +50°C Min./max. temp. (storage) from –50°C to +65°C Allowed inclinations ±10° Functional conditions - compressor external - condenser external - evaporator internal * - all data with ±10% tolerance

Page 32: Winterisation and Tropicalisation Systems - Start the interests of continued development, specifications may change from time to time without prior notice. • • • • • Technical

Webasto AGGlobal Comfort SolutionsP.O. Box 80D-82132 StockdorfGermanyTel: +49 (0)395 55 92-450Fax: +49 (0)395 55 92-353www.webasto.com

www.webasto.com

Advice · Installation · Service

CompactCooler_CC4E_q7.qxd:_ 23.11.2007 19:40 Uhr Seite 2