window replacement administration building ......window replacement administration building -...

8
OWNER: STATE OF MISSOURI MICHAEL L. PARSON, GOVERNOR PROJECT MANAGEMENT: OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT, DESIGN AND CONSTRUCTION DESIGNER: ROBERT ROLLINGS ARCHITECTS, LLC PROJECT NUMBER: E1906-01 ASSET NUMBER: 5012001008 WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8 SHEETS AUGUST 19, 2019 DEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

Upload: others

Post on 16-Sep-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

OWNER: STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

PROJECTMANAGEMENT:

OFFICE OF ADMINISTRATIONDIVISION OF FACILITIES MANAGEMENT,DESIGN AND CONSTRUCTION

DESIGNER: ROBERT ROLLINGSARCHITECTS, LLC

PROJECT NUMBER: E1906-01

ASSET NUMBER: 5012001008

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALL

MISSOURI SCHOOL FOR THE DEAFFULTON, MISSOURI

SHEET NUMBER:

G-001 1 OF 8 SHEETS

AUGUST 19, 2019

DEPARTMENT OFELEMENTARY AND SECONDARY EDUCATION

Page 2: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

1

A3.01

1

A2.01EXTERIOR ELEVATION

BUILDING SECTIONORDETAIL SECTION

1

A4.01

DETAILED SECTIONOR PLAN CALL-OUT

1

A3.01INTERIOR ELEVATION

4

A1.01

DRAWING NUMBER

SHEET NAME WHERE DRAWING IS FOUND

PLAN NORTH

OFFICE101

ROOM/SPACE NAMEAND REF. NUMBER

101 DOOR NUMBER

B WINDOW TYPE

G KEYED NOTE

6 EQUIPMENT NUMBER

SPOT ELEVATION ORFLOOR ELEVATION

PROJECT LOCATION

MARTIN LUTHER KING JR. BLVD

W 4TH ST

RTE OB

USI

NES

S 54

BLU

FF S

T

VIN

E ST

E 5TH ST

E 6TH ST

BUSINESS 54

BU

SIN

ESS

54

STA

TE S

T

PROJECT LOCATION

E. 5TH ST.

GR

AN

D A

VE.

VIN

E ST

.

STA

TE S

T.

E 6TH ST.E 6TH ST.

E. 5TH ST.

STORAGE / STAGING AREA

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

G-002

INFORMATIONSHEET

DESIGN TEAM:

ARCHITECT:

ROBERT ROLLINGS ARCHITECTS LLC1806 WEST BROADWAYSEDALIA, MO 65301660.829.9751 FAX: 660.829.9752

SHEET ORDER SHEET NUMBER SHEET NAME

1 G-001 COVER SHEET2 G-002 INFORMATION SHEET3 D-101 DEMOLITION PLAN4 A-101 FLOOR PLANS5 A-201 EXTERIOR ELEVATIONS6 A-202 EXTERIOR ELEVATIONS7 A-401 SECTION DETAILS8 A-601 WINDOW SCHEDULE / DETAILS

1" = 1'-0"G-0023 FULTON, MO

NOTE:

THESE DRAWINGS, ALONG WITH THE PROJECT SPECIFICATIONS, REPRESENT A UNIFIED SET OF CONSTRUCTION DOCUMENTS. ALL BIDDERS SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH ALL DRAWINGS IN THIS SET, REGARDLESS OF SHEET NUMBER AND DISCIPLINE, AND SHALL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE WORK OF OTHER TRADES. ANY APPARENT DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN THE DRAWINGS AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING.

DO NOT BID FROM PARTIAL SETS OF BID DOCUMENTS.

BY SUBMITTING A BID, BIDDERS REPRESENT THAT THEY HAVE VISITED THE SITE, BECOME FAMILIAR WITH THE BID DOCUMENTS IN THEIR ENTIRETY AND WITH LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED AND HAVE CORRELATED THE BIDDER'S PERSONAL OBSERVATIONS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.

GENERAL NOTES ARE INTENDED TO SUPPLEMENT THE DRAWINGS AND SPECIFICATIONS. NOT ALL NOTES APPLY TO THIS PROJECT. SPECIFIC TRADE NOTES TAKE PRECEDENCE OVER THESE GENERAL NOTES.

1. DESIGN LOADS:

A: BUILDING CODE - 2017 IBCB: ROOF LIVE LOAD - 20 PSFC: GROUND SNOW LOAD - 20 PSFD: WIND SPEED BASIC - 115 MPH

NOTE: THESE DRAWINGS ARE FOR THIS SPECIFIC BUILDING AND NO OTHER USE IS AUTHORIZED. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR EMBEDDED ITEMS NOT SHOWN HEREIN AND TO VERIFY SIZE AND LOCATION OF ALL OPENINGS. BEFORE EXECUTING ANYTHING HEREIN SHOWN, THE CONTRACTOR SHALL EXAMINE ACTUAL JOB CONDITIONS AND REPORT TO THE ARCHITECT ANY ERROR, OMISSION, OR DIFFICULTY AFFECTING THE WORK.

1" = 1'-0"G-0022 SITE LOCATION

SHEET 2 OF 8 08/19/2019

G_02

Page 3: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

D-101

4

D-101

5

1

1,5

3

1,5

11,51

11

6

6

766

66 1,58

8

8

8

8 5 5

55 1 65

88

8

44

44

44444

4

4 4 4 4 4 4 44 4

4 44

4

44 4

1 1 1 1 1 1 1

1 1 16

77

7 71 65 11 51 51 51 51 51 51 51

5 5 5 51 1 1 1 1

1,5

1,56

5

1,5 1,5 1,5

1,5 1,5 1,57 7 7 7 7

61,5

GC DEMO THROUGH WINDOW EXHAUST VENT AT THIS LOCATION.

OWNER WILL DISCONNECT ELECTRIC AND WHIP FROM J-BOX, TYP.

SALVAGE EXISTING WINDOW AC UNIT TO OWNER, TYP.

PHASE 2 & 3 PHASE 1PHASE 2 & 3 PHASE 1

PHASE 2 & 3 PHASE 1

2,5

2,5 1,5

1

1,5

1

1

1,5

11

11 1,5

6

6

6

7

6

66

66 1,5

8

8

8

8 5

55 1 65

88

8

4

4

44

44444

4

4 4 4 4 4 4 44 4

4 4 44

4

1,56

4

77

1 5 1 5 1 5 1 5 5

5

5

1,57 1,57 1,57 7

5

1,571,571,5

1,5

1 51 5 1 5 1 5 1 5 1 5 1 5 1 5 1 5 1 6

PHASE 2 & 3 PHASE 1

PHASE 2 & 3 PHASE 1

FIRST FLOOR0' - 0"

SECOND FLOOR11' - 4"

1 58 6 1 5

FIRST FLOOR0' - 0"

SECOND FLOOR11' - 4"

1 5 7

851 65151EXISTING LOUVERS TO REMAIN, TYP.

EXISTING WINDOW WITH VENT TO REMAIN

PHASE 2 & 3

INT.

EXT.

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

D-101

DEMOLITION PLAN

1/16" = 1'-0"D-1012 FIRST FLOOR DEMOLITION PLAN

1/16" = 1'-0"D-1013 SECOND FLOOR DEMOLITION PLAN

SHEET 3 OF 8 08/19/2019

3/8" = 1'-0"D-1014 DEMO ELEVATION 1

3/8" = 1'-0"D-1015 DEMO ELEVATION 2

GENERAL NOTES:

A. THE CONTRACTOR SHALL VERIFY ALL EXISTING JOBCONDITIONS & DIMENSIONS PRIOR TO BIDDING.

B. ALL WORK SHALL BE PERFORMED IN ACCORDANCEWITH THE GOVERNING AUTHORITY AND ALLAPPLICABLE BUILDING CODES.

C. ALL ITEMS TO BE REMOVED SHALL BECOMEPROPERTY OF THE CONTRACTOR (UNLESS OTHERWISENOTED) INCLUDING ALL DEBRIS AND SHALL BEREMOVED FROM THE PREMISES AS IT ACCUMULATES.

D. EXISTING ITEMS NOT SPECIFICALLY NOTED ARE TOREMAIN PROTECT FROM DAMAGE- TYPICAL.

E. THE DRAWING BACKGROUND WAS RECEIVED FROMTHE OWNER AND IS ASSUMED CORRECT.CONTRACTOR SHALL VERIFY DIMENSIONS &CONDITIONS BEFORE PROCEEDING.

F. ALL WORK AND MATERIALS ON THE DRAWINGS ANDIN THE SPECIFICATIONS ARE TO BE "NEW" UNLESSINDICATED AS EXISTING. "EXISTING" INDICATESITEMS THAT ARE EXISTING TO REMAIN AND TO BEPROTECTED FROM DAMAGE. "REMOVE" AND /OR "TOBE REMOVED" INDICATES ITEMS THAT ARE EXISTINGTO BE REMOVED.

KEYED DEMOLITION NOTES:

1. EXISTING ALUMINUM WINDOW, DEMOLISH WINDOWAND ALL MOUNTING HARDWARE, CLIPS, ETC. , TYP.

2. EXISTING STOREFRONT WINDOW, DEMOLISH WINDOWAND ALL MOUNTING HARDWARE, CLIPS, ETC. , TYP.

3. EXISTING HOLLOW METAL DOUBLE DOOR AND FRAMEW TRANSOM WINDOWS AND SIDELITES, DEMOLISHDOORS, FRAME, ALL MOUNTING HARDWARE, CLIPS,ETC. , TYP.

4. ABATE ASBESTOS CONTAINING MATERIAL, SEESPECIFICATIONS AND ASBESTOS REPORT, TYP.

5. PORCELAIN ENAMEL PANELS - CAREFULLY REMOVEALL EXISTING CAULK BETWEEN PANELS ANDALUMINUM WINDOWS, DO NOT DAMAGE FINISH ONANY MATERIAL OR SURFACE TO REMAIN, PROTECTDURING CONSTRUCTION, TYP.

6. CUT STONE SURROUND - CAREFULLY REMOVE ALLEXISTING CAULK BETWEEN CUT STONE SURROUNDAND ALUMINUM WINDOWS, DO NOT DAMAGE FINISHON ANY MATERIAL OR SURFACE TO REMAIN, PROTECTDURING CONSTRUCTION, TYP.

7. CUT STONE PILASTERS - CAREFULLY REMOVE ALLEXISTING CAULK BETWEEN LIMESTONE PILASTERSAND ALUMINUM WINDOWS, DO NOT DAMAGE FINISHON ANY MATERIAL OR SURFACE TO REMAIN, PROTECTDURING CONSTRUCTION, TYP.

8. EXISTING FACE BRICK -CAREFULLY REMOVE ALLEXISTING CAULK BETWEEN BRICK AND ALUMINUMWINDOWS, DO NOT DAMAGE FINISH ON ANYMATERIAL OR SURFACE TO REMAIN, PROTECT DURINGCONSTRUCTION, TYP.

A_DP_03

1/16" = 1'-0"D-1011 BASEMENT DEMOLITION PLAN

SALVAGE EXISTING WINDOW AC UNIT TO OWNER, TYP.

Page 4: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

A-201

A-201

1

A-201 5

A-202

1

4

I I II I II

F FF

I

E A A A A A AA AA E E EEE

E A A A EA HH

F

I

C C BB

E E

D D DDD

I

PHASE 1

PHA

SE 1

PHASE 1PHASE 2 & 3

PHA

SE 2

& 3

PHASE 2 & 3

100

A-201

A-201

1

A-201 5

A-202

1

4

C C B

AA

D

E A A A A A AA AA EEE

E A A A EAHJ

B

DD

J

D

E E

H E E

G

I

I

PHASE 2 & 3 PHASE 1

PHA

SE 1

PHASE 1PHASE 2 & 3

PHA

SE 2

& 3

M

M

K L K

PHASE 2 & 3

INT.

EXT.

GENERAL NOTESA. DO NOT SCALE DRAWINGS.B. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN

PROJECT DOCUMENTS AND EXISTING CONDITIONS. ANYMODIFICATIONS DUE TO DIMENSIONAL CHANGESSHOULD BE PART OF THE PROJECT COST.

C. GENERAL CONTRACTOR AND ALL SUBCONTRACTORSSHALL THOROUGHLY FAMILIARIZE THEMSELVES TOALL SITE SPECIFIC REQUIREMENTS AND EXTENTS OFWORK PRIOR TO BIDDING. NO CHANGES IN THECONTRACT WILL BE CONSIDERED FOR INFORMATIONDISCERNABLE FROM THE PROJECT DOCUMENTS.

D. GENERAL CONTRACTOR MAY HAVE TO COORDINATEWITH OWNERS CONTRACTORS OUTSIDE OF CONTRACT.

E. TYPICAL GROUND FLOOR FINISH FLOOR ELEVATIONSREFERENCED AS 0'-0". CONTRACTOR SHALL VERIFYBUILDING FINISH FLOOR ELEVATION W/ ACTUALCONDITIONS.

F. CAULK ALL JOINTS BETWEEN DISSIMILAR MATERIALSFOR WEATHER TIGHT, WATER TIGHT, AIR TIGHT ETC.PERFORMANCE.

G. EXISTING PLAN IS TAKEN FROM ORIGINALCONSTRUCTION DOCUMENTS SEALED IN 1957 AND AREASSUMED TO BE CORRECT. GC SHALL INVESTIGATEAND VERIFY EXISTING DIMENSIONS AND CONDITIONSARE SIMILAR TO CONDITIONS SHOWN. IMMEDIATELYNOTIFY PROJECT MANAGER AND ARCHITECT OF ANYDISCREPANCIES, TYP.

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

A-101

FLOOR PLANS

1/16" = 1'-0"A-1011 FIRST FLOOR PLAN

1/16" = 1'-0"A-1012 SECOND FLOOR PLAN

SHEET 4 OF 8 08/19/2019

A_FP_04

1/16" = 1'-0"A-1013 BASEMENT PLAN

12" = 1'-0"A-1014 GENERAL NOTES

Page 5: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

E E

EE E

E A

A

A

A A

A A

A

A

A

A

A A

A A

A A

A E

E E E

EE

J

D D D D

DDDD F F F F

A-4011

A-4013

A-4012

A-4014

A-4015

A-4016 A-401

7A-401

8

A-2012

A-2013

PHASE 2 & 3 PHASE 1

K L K

M

G

5 61 2

7

PHASE 2 & 3

A-4016

A-4018

100I

I

I

I

5 61 3

2

1

2

1 1

6 3

PHASE 1

A-4011

A-4016

A-4018

A-4014

66

FIRST FLOOR0' - 0"

ROOF BEARING22' - 8"

SECOND FLOOR11' - 4"

E E

EE E

E A

A A

A A

A A

A A A A A

AAAA A

A E

E E

E E

E

J

A-4011

A-4013

A-4012

A-4014

A-4015

1 2 36 5

2

A-4013

11 2 36 1 26 3 1 26 1 26 1 26 1 26 1 26 1 26 1 26 1 26 1 26 1 6 1 26 1 6 1 63 3 3

2 6 11

5

11 2 36 1 26 3 1 26 1 26 1 26 1 26 1 26 1 26

1 26 1 26 1 26 1 6 1 26 1 6

6

3 3

35

EXISTING INSULATED METAL PANEL TO REMAIN.

K L K

PHASE 2 & 3

FIRST FLOOR0' - 0"

ROOF BEARING22' - 8"

SECOND FLOOR11' - 4"

NOT IN SCOPE OF PROJECT, TYP.

D D

D D

D D

D F F F FD

A-4016

A-4017

A-4018

1 62

126

1 6 1 6 1 62225

4 12 46 12 46 12 46 12 46

4 12 46 12 46 12 46 12 46 2222

PHASE 1

M

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

A-201

EXTERIORELEVATIONS

1/16" = 1'-0"A-2011 SOUTH ELEVATION

3/32" = 1'-0"A-2015 WEST ELEVATION

3/32" = 1'-0"A-2014 EAST ELEVATION SHEET 5 OF 8

08/19/2019

1/8" = 1'-0"A-2012 SOUTH ELEVATION A

1/8" = 1'-0"A-2013 SOUTH ELEVATION B

A_EL_05

KEY:1. NEW ALUMINUM WINDOW, TYP.2. EXISTING PORCELAIN ENAMEL PANELS, TYP.3. EXISTING CUT STONE SURROUND, TYP.4. EXISTING CUT STONE PILASTERS, TYP.5. EXISTING FACE BRICK, TYP.6. APPLY SEALANT AS SPECIFIED @ ALL JOINTS

BETWEEN WINDOWS AND THE PORCELAIN ENAMELPANELS, THE BRICK, THE ADJACENT CUT STONEPILASTERS, AND THE CONCRETE BASE. – TYPICAL.

7. NEW STOREFRONT DOOR AND FRAME, TYP.

Page 6: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

I I I I I I I I

AA E E

EE

B C

CB

C

C

B

B

H

H

E A A A A E H J

HEAAAAE

A-2022

A-2023

PHASE 1 PHASE 2 & 3

M

FIRST FLOOR0' - 0"

ROOF BEARING22' - 8"

SECOND FLOOR11' - 4"

NOT IN SCOPE OF PROJECT, TYP.

EE

E E

AA

I I I IIIII

61561 61 61

61 61 61 61

615 3 2 61 61 615 32 61

61 32 61

PHASE 2 & 3PHASE 1

5

A-4011

A-4013

A-4012

A-4014

M

FIRST FLOOR0' - 0"

ROOF BEARING22' - 8"

SECOND FLOOR11' - 4"

H

HE

EAAAAEH

H E A A A A

J

B

B

C

CC

CB

B

EE

E E

61 53 2 6161 261 261 261 261 23 61 23 61

2

3

613 2 6161 261 261 261 261 61

61 461 461 461 4 222 2

61616161 222 2

1261 63 5 4

1261 63

PHASE 2 & 3

A-4016

A-4018

A-4017

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

A-202

EXTERIORELEVATIONS

1/16" = 1'-0"A-2021 NORTH ELEVATION

1/8" = 1'-0"A-2022 NORTH ELEVATION A

1/8" = 1'-0"A-2023 NORTH ELEVATION B

SHEET 6 OF 8 08/19/2019

A_EL_06

KEY:1. NEW ALUMINUM WINDOW, TYP.2. EXISTING PORCELAIN ENAMEL PANELS, TYP.3. EXISTING CUT STONE SURROUND, TYP.4. EXISTING CUT STONE PILASTERS, TYP.5. EXISTING FACE BRICK, TYP.6. APPLY SEALANT AS SPECIFIED @ ALL JOINTS

BETWEEN WINDOWS AND THE PORCELAIN ENAMELPANELS, THE BRICK, THE ADJACENT CUT STONEPILASTERS, AND THE CONCRETE BASE. – TYPICAL.

7. NEW STOREFRONT DOOR AND FRAME, TYP.

Page 7: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

NEW CAULK, TYP

1' - 0"

8"

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

EXISTING STONE SURROUND, TYP.

EXISTING CONCRETE WALL, TYP.

NEW CAULK, TYP

EXISTING MASONRY BRICK, TYP.

7 5/8"NEW CAULK, TYP

EXISTING 1" x 1/16" S. STEEL ANCHORS, TYP.

1 1/

8"

EXISTING CMU WALL, TYP.

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

EXISTING STONE SURROUND, TYP.

EXISTING MASONRY BRICK, TYP.

NEW CAULK, TYP

8"2"

EXISTING INSULATED PORCELAIN ENAMEL

PANEL, TYP.

NEW CAULK, TYP.

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

EXISTING CONCRETE COLUMN, TYP.

NEW CAULK, TYP.

3 1/4"

9"1"

7/8"

EXISTING MARBLE STOOL, TYP.

4"5/

8"1

1/4"

1' - 0"

NEW ALUMINUM WINDOW AND SILL FLASHING, TYP.

EXISTING MASONRY WALL, TYP.

EXISTING STONE SURROUND, TYP.

NEW CAULK, ALLOW FOR WEEP, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP.

1"

7/8"

EXISTING MARBLE STOOL, TYP.

EXISTING INSULATED PORCELAIN ENAMEL PANEL, TYP.

NEW SILL EXTENSION, VERIFY DIMENSIONS IN FIELD AND SUPPLY RECOMMENDED

EXTENSION BY WINDOW MANUFACTURER, SUBMIT TO DESIGNER FOR APPROVAL

PRIOR TO INSTALLATION, TYP.

NEW ALUMINUM WINDOW AND SILL FLASHING, TYP.

NEW CAULK, ALLOW FOR WEEP, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP

EXISTING 3/4" ACOUSTICAL TILE, TYP.

2" 8"

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

EXISTING CONCRETE COLUMN, TYP.

EXISTING INSULATED PORCELAIN ENAMEL

PANEL, TYP.

EXISTING CUT STONE PANELS

EXISTING CONCRETE COLUMN, TYP. EXISTING CMU OR

MASONRY BLOCKING, VERIFY IN FIELD, MAY VARY PER LOCATION, TYP.

VERIFY MOUNTING CONDITION IN FIELD, EXISTING DRAWINGS SHOW A "Z" OR SIMILAR TYPE CLIP, TYP.

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

NEW ALUMINUM WINDOW AND 1x2 SNAP TRIM, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP.

NEW CAULK, TYP.

1' - 0"

8"

EXISTING CEMENT STOOL, TYP.

INSTALL NEW TREATED SOLID WOOD BLOCKING OR SIMILAR AS REQUIRED FOR SECURE ATTACHMENT OF SILL, TYP.

EXISTING STONE SURROUND, TYP.

NEW ALUMINUM WINDOW AND SILL FLASHING, TYP.NEW CAULK,

ALLOW FOR WEEP, TYP. NEW CAULK, TYP.

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

A-401

SECTION DETAILS

1 1/2" = 1'-0"A-4011 HEAD DETAIL 1

1 1/2" = 1'-0"A-4012 JAMB DETAIL 1

1 1/2" = 1'-0"A-4013 JAMB DETAIL 2

1 1/2" = 1'-0"A-4014 SILL DETAIL 1

1 1/2" = 1'-0"A-4018 SILL DETAIL 2

1 1/2" = 1'-0"A-4016 HEAD DETAIL 2

1 1/2" = 1'-0"A-4017 JAMB DETAIL 3

1 1/2" = 1'-0"A-4015 SILL DETAIL 3

NOTES:1. EXISTING DETAILS ARE TAKEN FROM ORIGINAL

CONSTRUCTION DOCUMENTS SEALED IN 1957 AND AREASSUMED TO BE CORRECT. GC SHALL INVESTIGATE ANDVERIFY EXISTING DIMENSIONS AND CONDITIONS ARESIMILAR TO CONDITIONS SHOWN. IMMEDIATELY NOTIFYPROJECT MANAGER AND ARCHITECT OF ANYDISCREPANCIES, TYP.

2. ALL ATTACHMENT, CAULKING, SEALING, JOINING TOEXISTING MATERIALS SHALL BE IN ACCORDANCE TOWINDOW MANUFACTURERS RECOMMENDATIONS.

3. INTENT OF THE PROJECT IS TO REMOVE EXISTINGWINDOWS AND INSTALL NEW WINDOWS OF THE SAMEDEPTH. GC SHALL VERIFY WINDOW DEPTHS ON SITE ANDSUPPLY ADDITIONAL TRIM AS NEEDED TO PROVIDE ACLEAN, FINISHED LOOK, TYP.

SHEET 7 OF 8 08/19/2019

A_DT_07

Page 8: WINDOW REPLACEMENT ADMINISTRATION BUILDING ......WINDOW REPLACEMENT ADMINISTRATION BUILDING - WHEELER HALL MISSOURI SCHOOL FOR THE DEAF FULTON, MISSOURI SHEET NUMBER: G-001 1 OF 8

6' - 8

" ±

2' - 8

" ±

7' - 7 1/2" 11' - 7"

2' - 8

" ±

MLKJ

GA B C D E F

6' - 8

" ±

4' - 0" ±

5' - 4

" ±

7' - 7 1/2" ±

6' - 8

" ±

6' - 8

" ±

7' - 6

" ±

8' - 0" ±

5' - 4

" ±

11' - 7" ±

6' - 8

" ±

11' - 7" ± 11' - 6 1/2" ± 11' - 8" ± 8' - 8 3/4" ±

12' -

0" ±

3' - 8" ±

NOTE: G.C. VERIFY ALL ROUGH OPENINGS IN FIELD.

E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q. E.Q.

18' - 0" ±

8' - 7

3/4

" ±

4' - 3" 3' - 2" 3' - 2" 3' - 2" 4' - 3"

4' - 1

0"1'

- 10"

4' - 1

0"1'

- 10"

4' - 1

0"1'

- 10"

3' - 6

"1'

- 10"

4' - 1

0"1'

- 10"

5' - 8

"1'

- 10"

3' - 6

"1'

- 10"

4' - 1

0"1'

- 10"

EQ.

EQ.

EQ.

EQ.

I

6' - 8

" ±

H

3' - 8" ±

TRANSLUCENT GLASS, TYP.

4' - 1

0"1'

- 10"

INSULATED METAL PANEL, SEE SPECS.

2A-601

4A-601

3A-601 5

A-601

6A-601

5 1/4"

1"

1/4"

UN

IT D

IMEN

SIO

N

ROU

GH

OPE

NIN

G

1 7/

8"

ROUGH OPENING

1"

1/4"1 7/8"

2"

UNIT DIMENSION

1 7/

8"

3 1/

4"

END DAM SUBSIL IN FIELD BY THE INSTALLER, TYP.

UN

IT D

IMEN

SIO

N3/

8"1/

4"

ROU

GH

OPE

NIN

G

3"

OFF

SET

DIM

ENSI

ON

UNIT DIMENSIONUNIT DIMENSION

1 7/8" 1" 1 7/8"

100

8' - 8 3/4" ±

8' - 8

1/2

" ±

7' - 0

"

3' - 0"

1' - 2 1/4" 3' - 2" 3' - 2" 1' - 2 1/2"

1' - 7

1/2

"5'

- 2"

1' - 1

1"

3' - 0"

NOTE: G.C. VERIFY ALL ROUGH OPENINGS IN FIELD.

ALUMINUM STOREFRONT, TYP.

WINDOW REPLACEMENTADMINISTRATION BUILDING - WHEELER HALLMISSOURI SCHOOL FOR THE DEAF505 E 5TH ST,FULTON MO 65251

E1906-01

08/19/2019ISSUE DATE:

SHEET NUMBER:

CHECKED BY: RDRDRAWN BY: AMK

DESIGNED BY: AMK

DATE:REVISION:

PROJECT # ASSET # 5012001008

SHEET TITLE:

REVISION:DATE:

REVISION:DATE:

CAD DWG FILE:

STATE OF MISSOURIMICHAEL L. PARSON,GOVERNOR

1806 West Broadway BoulevardSedalia, MO 65301660.829.9751

BID DOCUMENTS

Robert D. Rollings 2005001208, Certificate of Authority # A-2006003870

OFFICE OF ADMINISTRATION DIVISION OF FACILITIES MANAGEMENT DESIGN AND CONSTRUCTIONDEPARTMENT OF ELEMENTARY AND SECONDARY EDUCATION

A-601

WINDOW SCHEDULE/ DETAILS

1/4" = 1'-0"WINDOW TYPES

1/4" = 1'-0"A-6011 WINDOW DETAIL

6" = 1'-0"A-6012 WINDOW HEAD DETAIL

6" = 1'-0"A-6013 WINDOW JAMB DETAIL

6" = 1'-0"A-6014 WINDOW SILL DETAIL

6" = 1'-0"A-6015 HORIZONTAL MULLION DETAIL

6" = 1'-0"A-6016 VERTICAL MULLION DETAIL

ADJUST DETAIL AS REQUIRED TO MATCH SELECTED WINDOW OPTION

SHEET 8 OF 8 08/19/2019

A_SH_08

1/4" = 1'-0"DOOR TYPES