window ventilators4 regulations < introduction brief guide to uk building regulations, part f -...

80
Window ventilators

Upload: others

Post on 01-Jan-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

Window ventilators

Page 2: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

Contents < Introduction

Contents

Cover: Residence Zurenborg, Antwerp (BE), Velaert Architecten

INTRODUCTION

Need for ventilation 3

Brief guide to UK building regulations, part F - ventilation 4

i-Flux®principle: technology self-regulating 5

Overview technical characteristics 6

OVERFRAME FLAP VENTILATORS

Thermally broken

Invisivent® EVO 8

Invisivent® EVO HF 10

Thermally broken and sound absorbing

Invisivent® EVO AK 12Invisivent® EVO AK Basic 13Invisivent® EVO AK High 14Invisivent® EVO AK Ultra 15Invisivent® EVO AK Extreme 16

Invisivent® EVO AKD (Max) 17

Invisivent® EVO HR 19Invisivent® EVO HR Basic 20Invisivent® EVO HR High 21Invisivent® EVO HR Ultra 22

AKR33-module 23

Invisivent® EVO UT 24

Invisivent® EVO range 26

FLAP VENTILATORS GLAZED-IN/AT TRANSOM

Thermally broken

TC45 28

TC60 30

AR60-THK60 32

AR75 34

AR90-THK90 36

THM90EVO/THM90PBEVO/THM90TREVO 38

Thermally broken and sound absorbing

AK80EVO - AK80 40

AK80GL 42

Sonovent® 44

Sonovent® Compact 48

Sonovent® I 50

Sonovent® V 52

FLAP VENTILATOR FOR CONSERVATORIES

Oxyvent® 54

ACOUSTIC VENTILATOR FOR SLANT ROOFS

Sonovent® D 56

ROLLER SHUTTER FLAP VENTILATOR

Transivent® 58

SLIDING VENTS

THL100 – THL100V 60

T67 – T100 – T130 – T150 62

TL67 – TL100 – TL100 PB 64

SLOTVENTS

Introduction 66

Interior slotvents 67

Exterior slotvents 69

Sonoslot® 71

Sonoslot® Max 72

Slotvent combinations 73

COMBINED VENTILATION AND SUN SHADING OVERFRAME

Fixvent® Mono AKEVO 74

EPILOGUE

Additional info 76

How to ventilate in an energy-efficient residence? 78References 79

Note: please contact RENSON® to check availability of the products in your country.

Page 3: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

Every day, the indoor air is being polluted by its inhabitants (breathing, sweating), through their activities (cooking, showering, heating and smoking), but also by the building itself and its furnishing (radon, volatile organic compounds, paint, detergents,...). Excessive insulation and inadequate ventilation create a dead and stale air which accumulates mites, molds, viruses, bacteria, as well as moisture and harmful chemicals such as CO

2.

A poor indoor climate may cause breathing problems, dry throat, eye irritation, headaches, allergies, impaired concentration, lack of energy, sleepiness, .... Moreover, excess moisture in the home can cause odors, condensation and mold growth, hence the importance to properly ventilate on a regular basis.

Ventilation: for you and your home!

Many people think that opening the window from time to time is sufficient. However, the effect of opening a window is only temporary and ventilation through open windows is uncontrollable (and therefore wasted energy). In addition, opening the window leads to other problems such as noise, the risk of burglary, the intrusion of insects and so on.

Continuous and controlled ventilation is the only effective method to ensure a healthy indoor climate.

Need for ventilation

≥ 1850 ppm

1850 ppm

650 ppm

950 ppm

1250 ppm

1500 ppm

Healthy

Healthy

Acceptable

Temporarily acceptable

Unhealthy

Unhealthy

Indoor air quality

Page 4: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

4

Regulations < Introduction

Brief guide to UK building regulations, part F - ventilation

Domestic buildings

New Buildings (with any design air permeability)Previously ventilation area was shown in free area mm2 whereas now it is calculated and shown as Equivalent Area (EA) per mm2 as in the table shown below based upon 2 occupants in the main bedroom and a single occupant in all other bedrooms.

total floor area (m2) Number of Bedrooms

1 2 3 4 5

< 50 35000 40000 50000 60000 65000

51 – 60 35000 40000 50000 60000 65000

61 – 70 45000 45000 50000 60000 65000

71 – 80 50000 50000 50000 60000 65000

81 – 90 55000 60000 60000 60000 65000

91 – 100 65000 65000 65000 65000 65000

> 100 add 7000 mm2 for every additional 10 m2 floor area

The minimum equivalent area (EA) for habitable rooms is 5000 mm2 EA and for any wet room 2500 mm2 EA.

Please contact RENSON UK for more information regarding basements, habitable rooms with non opening windows, modular or portable buildings and acoustic needs for buildings.

Existing BuildingsWhere renovations are being carried out to an existing building then the background ventilation should not be smaller than originally provided, but it must be at least 5000 mm2 EA for habitable rooms and 2500 mm2 EA for wet rooms.

Please contact RENSON UK for more information regarding connecting to a conservatory, addition of a wet room or addition of a habitable room.

Non-domestic buildings

New Offices10 l/s (litres per second) per person of air supply is needed

Existing offices, hotels, ...Floor area under 10m2 - 2500 mm2 EAFloor area over 10m2 - 250 mm2/m2 EAKitchens - 2500 mm2 EABathrooms/showers/WC - 2500 mm2 EA per bath, shower or toilet

New schools (according to Building Bulletin 101) 8 l/s (litres per second) per person of air supply is needed.

Page 5: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

5

Introduction > Principles

Unique, self-regulating flap ventilators: innovative and energy-saving

i-Flux® technologyBy applying the i-Flux Technology, RENSON® can guarantee an optimal comfort and minimize energy loss with its ventilators. i-Flux Technology is based upon the following three principles:

1. Airflow independent of wind pressure: by means of a self-regulating flap in the ventilator that immediately reacts to wind pressure differences, the airflow remains

constant (also at high wind forces) and draught is avoided.

2. Adjustable airflow by means of a manually adjustable interior flap: the inhabitant can determine himself which level of airflow is required (e.g. in function of the occupancy of the room).

3. Incoming air deflected upwards for an optimal comfort: by the specific shape of the interior flap, incoming fresh air is deflected upwards, ensuring an optimal spread of the fresh

air in the room and hence an optimal comfort for the inhabitants.

Airflow independent of wind pressure

n Self regulatingn Not self-regulating

Pressure-

difference in Pa

Airflow

in m³/h/m

Interior flap closed Interior flap half-open Interior flap open

Incoming air upwards Detail of incoming air upwards

è

Self-regulating flap

Page 6: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

6

* not for installation at transom • ** other thickness on request • *** 2000 mm glazed-in installation / 2500 mm installation at transomn.p.d. : no performances determined • n.a. : not applicable

Overview technical characteristics < Introduction

Page Equivalent Area

(mm2/m)

Q at 1 Pa (l/s/m)

Q at 1 Pa (m³/h/m)

Q at 2 Pa (l/s/m)

Q at 2 Pa (m³/h/m)

Q at 10 Pa (l/s/m)

Q at 20 Pa (l/s/m)

Free area (mm2/m)

Sound reduction D

n,e,w (C;C

tr) in

open position (dB/m)

U-value (W/m²K)

Self- regulating

i-FLux®

Glass reduction

(mm)

Glass thickness (mm)

Finish Maximum length (mm)

Overframe flap ventilators Overframe flap ventilatorsINVISIVENT® EVO 8 13728 10,8 38,8 14,3 51,3 13,1 14,4 15000 27 (-1;-1) 2,8 yes yes 0 n.p.d. anodised/ RAL / dual color 6000 INVISIVENT® EVO

INVISIVENT® EVO HF 10 17942 14,1 50,8 18,5 66,6 16,5 18,0 15100 28 (-1;-2) 2,8 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HFINVISIVENT® EVO AK Basic 12 13489 10,6 38,2 15,9 57,2 17,9 16,0 12550 34 (0;-1) 2,0 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK BasicINVISIVENT® EVO AK High 14 9349 7,3 26,5 11,6 41,7 14,0 11,8 9765 39 (0;-1) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK HighINVISIVENT® EVO AK Ultra 15 7016 5,5 19,9 9,1 32,8 8,0 9,8 6916 42 (0;-2) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK UltraINVISIVENT® EVO AK Extreme 16 2404 1,9 6,8 2,8 9,9 6,4 9,3 2069 48 (0;-2) 1,7 no no 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK ExtremeINVISIVENT® EVO AKD 17 4961 3,9 14,0 5,6 20,3 13,3 19,3 5331 39 (0;-2) 1,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKDINVISIVENT® EVO AKD Max 17 1400 1,1 4,0 1,7 6,1 4,0 5,7 1354 47 (-1;-4) 1,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKD MaxINVISIVENT® EVO HR Basic 20 13489 10,6 38,2 15,9 57,2 17,9 16,0 12550 34 (0;-1) 2,0 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR BasicINVISIVENT® EVO HR High 21 9349 7,3 26,5 11,6 41,7 14,0 11,8 9765 39 (0;-1) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR HighINVISIVENT® EVO HR Ultra 22 7016 5,5 19,9 9,1 32,8 8,0 9,8 6919 42 (0;-2) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR UltraINVISIVENT® EVO AKR33-module 23 11818 9,3 33,4 12,9 46,6 11,6 12,9 13000 33 (-1;-2) 3,6 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKR33-moduleINVISIVENT® EVO UT 24 10092 7,9 28,6 12,3 44,2 30,7 33,6 9765 39 (0;-1) 2,2 as from 10 Pa yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO UTFlap ventilators glazed-in/at transom Flap ventilators glazed-in/at transomTC45 28 10435 8,2 29,5 11,5 41,4 25,8 36,5 11333 27 (0;0) 4,1 no no 45 20/24/28 anodised / RAL / dual color 2500 TC45TC60 30 15652 12,3 44,3 17,4 62,6 38,9 55,0 12314 28 (0;0) 3,3 no no 60 20/24/28 anodised / RAL / dual color 2500 TC60AR60 32 10427 8,2 29,5 11,8 42,3 19,7 23,9 14900 27 (0;0) 4,5 yes yes 60 20/24/28 anodised / RAL / dual color 2500 AR60THK60 32 11841 9,3 33,5 13,2 47,5 29,6 41,8 14841 27 (0;0) 4,5 no no 60 20/24/28 anodised / RAL / dual color 2500 THK60AR75 Small 34 14174 11,1 40,1 15,3 54,9 17,3 14,7 10762 26 (-1;-1) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 SmallAR75 Medium 34 17409 13,7 49,3 18,8 67,5 21,4 18,9 13531 26 (-1;-2) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 MediumAR75 Large 34 19034 15,0 53,9 22,6 81,3 24,5 21,7 16171 26 (-1;-2) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 LargeAR75 Xlarge 34 24301 19,1 68,8 29,0 104,3 31,5 28,0 18431 26 (-1;-1) 3,0 yes no 75/77 20/24/28/32/36* anodised / RAL / dual color 2500 AR75 XlargeAR90 36 14252 11,2 40,3 15,6 56,2 11,4 9,1 11070 30 (-1;-2) 3,9 yes no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) AR90THK90 36 14736 11,6 41,7 16,1 57,9 34,5 48,0 14120 28 (0;-1) 3,9 no no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) THK90THM90EVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24/28/33 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90EVO

THM90PBEVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90PBEVO

THM90TREVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90TREVO

AK80EVO/1 40 n.p.d. 0,6 2,0 1,1 4,1 3,5 3,7 1280 47 (0;-3) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/1AK80EVO/2 40 n.p.d. 0,9 3,2 1,7 6,2 5,4 5,8 2080 44 (-1;-4) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/2AK80EVO/3 40 n.p.d. 1,3 4,7 2,1 7,5 6,6 6,3 2440 41 (-1;-3) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/3AK80EVO/4 40 n.p.d. 4,1 14,8 6,6 23,6 20,5 19,6 5293 33 (-1;-2) 2,1 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/4AK80/1 40 1488 1,2 4,2 1,6 5,9 3,6 5,0 1280 47 (0;-3) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/1AK80/2 40 2163 1,7 6,1 2,5 9,0 5,8 8,4 2080 44 (-1;-4) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/2AK80/3 40 2545 2,0 7,2 2,9 10,4 7,1 10,4 2440 41 (-1;-3) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/3AK80/4 40 8780 6,9 24,8 9,7 34,9 21,1 29,6 6680 33 (-1;-2) 2,1 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/4AK80GL/1 42 1488 1,2 4,2 1,6 5,9 3,6 5,0 1280 47 (0;-3) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/1AK80GL/2 42 2163 1,7 6,1 2,5 9,0 5,8 8,4 2080 44 (-1;-4) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/2AK80GL/3 42 2545 2,0 7,2 2,9 10,4 7,1 10,4 2440 41 (-1;-3) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/3AK80GL/4 42 8780 6,9 24,8 9,7 34,9 21,1 29,6 6680 33 (-1;-2) 2,1 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/4SONOVENT® Small 10 44 17756 14,0 50,2 14,0 50,2 15,3 22,9 10000 46 (-1;-5) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 10SONOVENT® Small 15 44 29593 23,3 83,7 23,3 83,7 25,6 28,5 11000 41 (-1;-2) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 15SONOVENT® Small 20 44 31813 25,0 90,0 25,0 90,0 27,5 29,2 18900 40 (-1;-3) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 20SONOVENT® Small 25 44 33786 26,6 95,6 26,6 95,6 29,2 27,1 22300 37 (-1;-3) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 25SONOVENT® Medium 10 44 17509 13,8 49,5 13,8 49,5 15,1 n.p.d. 10000 48 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 10SONOVENT® Medium 15 44 26511 20,8 75,0 20,8 75,0 22,9 n.p.d. 11000 45 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 15SONOVENT® Medium 20 44 33292 26,2 94,2 26,2 94,2 28,8 n.p.d. 18900 43 (0;-3) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 20SONOVENT® Medium 25 44 34032 26,7 96,3 26,7 96,3 29,4 27,5 22300 39 (-1;-4) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 25SONOVENT® Large 10 44 16153 12,7 45,7 12,7 45,7 14,0 n.p.d. 10000 50 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 10SONOVENT® Large 15 44 25524 20,1 72,2 20,1 72,2 22,1 n.p.d. 11000 49 (-2;-7) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 15SONOVENT® Large 20 44 32059 25,2 90,7 25,2 90,7 27,7 n.p.d. 18900 44 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 20SONOVENT® Large 25 44 33416 26,3 94,5 26,3 94,5 28,9 25,0 22300 41 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 25SONOVENT® XLarge 10 44 14427 11,3 40,8 11,3 40,8 12,5 n.p.d. 10000 56 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 10SONOVENT® XLarge 15 44 21578 17,0 61,0 17,0 61,0 18,7 n.p.d. 11000 53 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 15SONOVENT® XLarge 20 44 31073 24,4 87,9 24,4 87,9 26,9 n.p.d. 18900 46 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 20SONOVENT® XLarge 25 44 32676 25,7 92,4 25,7 92,4 28,2 n.p.d. 22300 45 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 25SONOVENT® Compact 10 48 15334 12,1 43,4 16,4 58,9 17,3 17,8 9500 36 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 10SONOVENT® Compact 13 48 19278 15,2 54,5 18,8 67,7 18,8 18,7 12500 35 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 13SONOVENT® Compact 15 48 24687 19,4 69,8 19,9 71,5 18,6 19,1 15000 33 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 15SONOVENT® I Small 50 43520 34,2 123,1 48,2 173,5 107,8 152,4 35857 32 (-1;-3) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I SmallSONOVENT® I Medium 50 44029 34,6 124,6 48,7 175,3 107,1 150,5 35857 33 (-1;-3) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I MediumSONOVENT® I Large 50 43392 34,1 122,8 48,0 172,8 107,3 151,8 35857 35 (-1;-4) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I LargeSONOVENT® I Xlarge 50 43138 33,9 122,0 48,0 172,8 107,3 151,8 35857 36 (-1;-4) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I XlargeFlap ventilators for conservatories Flap ventilators for conservatoriesOxyvent® 54 15058 11,8 42,6 16,7 60,2 37,4 52,9 19300 27 (-1;-2) 2,8 no no 210 28 - 86 (by steps of 2 mm) RAL / dual color 1500 Oxyvent®Acoustic ventilator for slant roofs Acoustic ventilator for slant roofsSONOVENT® D Small 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 37 (-1;-3) 4,5 yes no n.a n.a RAL / dual color 1000 SONOVENT® D SmallSONOVENT® D Medium 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 39 (-1;-4) 4,6 yes no n.a n.a RAL / dual color 1000 SONOVENT® D MediumSONOVENT® D Large 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 41 (-2;-6) 4,6 yes no n.a n.a RAL / dual color 1000 SONOVENT® D LargeRoller shutter flap ventilator Roller shutter flap ventilatorTransivent® 58 13748 10,8 38,9 15,2 54,6 20,1 19,9 16368 28 (-1;-2) 3,0 yes yes n.a. n.a. anodised / RAL 2200 (1500 mm for cord control) Transivent®Sliding vents Sliding ventsTHL100 60 16759 13,2 47,4 18,7 67,2 41,6 58,9 16200 22 (0;-1) 3,9 no no 129 15*/20/24/28 anodised / RAL / dual color 3500 THL100THL100V 60 12770 10,0 36,1 14,2 51,3 32,1 45,5 27950 22 (0;-1) 3,9 no no 129 15*/20/24/28 anodised / RAL / dual color 3500 THL100VT67 62 11224 8,8 31,8 12,7 45,7 28,5 40,2 16330 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T67T100 62 17326 13,6 49,0 19,5 70,3 43,8 61,9 25342 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T100T130 62 24589 19,3 69,6 27,7 99,8 62,1 87,9 38302 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T130T150 62 27992 22,0 79,2 31,9 114,8 71,5 101,0 45592 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T150TL67 64 10137 8,0 28,7 11,4 41,4 25,3 36,2 16330 n.p.d. n.p.d. no no 98 20 anodised / RAL / dual color 3500 TL67TL100 64 14198 11,2 40,2 16,0 57,5 35,8 50,6 25342 n.p.d. n.p.d. no no 129 4/20/24 anodised / RAL / dual color 3500 TL100TL100 PB 64 14198 11,2 40,2 16,0 57,5 35,8 50,6 25342 n.p.d. n.p.d. no no 129 20 anodised / RAL / dual color 3500 TL100 PBSlotvents SlotventsSonoslot®, 275 mm 71 1273 1,0 3,6 1,4 5,0 3,2 3,3 1256 38 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 275 Sonoslot®, 275 mmSonoslot®, 375 mm 71 1607 1,3 4,5 1,7 6,2 4,0 4,2 1885 37 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 375 Sonoslot®, 375 mmSonoslot®, 475 mm 71 2121 1,7 6,0 2,3 8,3 5,3 5,6 2513 36 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 475 Sonoslot®, 475 mmSonoslot®, 700 mm 71 3181 2,5 9,0 3,4 12,4 8,0 8,4 3769 34 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 700 Sonoslot®, 700 mmSonoslot® Max without damping 72 2298 1,8 6,5 2,7 9,7 6,8 6,9 1871 38 (-1;-2) n.p.d. yes no n.a. n.a. Renson standard WHITE / RAL 1247 700 Sonoslot® Max without dampingSonoslot® Max with damping 72 1555 1,2 4,4 1,9 6,8 5,1 7,6 1871 40 (-1;-2) n.p.d. yes no n.a. n.a. Renson standard WHITE / RAL 1247 700 Sonoslot® Max with dampingCombined ventilation and sun shading overframe Combined ventilation and sun shading overframeFixvent® Mono AKEVO See technical values on page 74-75 See technical values on page 74-75 Fixvent® Mono AKEVO

Airflow based upon aluminiumsize = 1000 mm (except slotvents)

Page 7: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

7

Page Equivalent Area

(mm2/m)

Q at 1 Pa (l/s/m)

Q at 1 Pa (m³/h/m)

Q at 2 Pa (l/s/m)

Q at 2 Pa (m³/h/m)

Q at 10 Pa (l/s/m)

Q at 20 Pa (l/s/m)

Free area (mm2/m)

Sound reduction D

n,e,w (C;C

tr) in

open position (dB/m)

U-value (W/m²K)

Self- regulating

i-FLux®

Glass reduction

(mm)

Glass thickness (mm)

Finish Maximum length (mm)

Overframe flap ventilators Overframe flap ventilatorsINVISIVENT® EVO 8 13728 10,8 38,8 14,3 51,3 13,1 14,4 15000 27 (-1;-1) 2,8 yes yes 0 n.p.d. anodised/ RAL / dual color 6000 INVISIVENT® EVO

INVISIVENT® EVO HF 10 17942 14,1 50,8 18,5 66,6 16,5 18,0 15100 28 (-1;-2) 2,8 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HFINVISIVENT® EVO AK Basic 12 13489 10,6 38,2 15,9 57,2 17,9 16,0 12550 34 (0;-1) 2,0 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK BasicINVISIVENT® EVO AK High 14 9349 7,3 26,5 11,6 41,7 14,0 11,8 9765 39 (0;-1) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK HighINVISIVENT® EVO AK Ultra 15 7016 5,5 19,9 9,1 32,8 8,0 9,8 6916 42 (0;-2) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK UltraINVISIVENT® EVO AK Extreme 16 2404 1,9 6,8 2,8 9,9 6,4 9,3 2069 48 (0;-2) 1,7 no no 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AK ExtremeINVISIVENT® EVO AKD 17 4961 3,9 14,0 5,6 20,3 13,3 19,3 5331 39 (0;-2) 1,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKDINVISIVENT® EVO AKD Max 17 1400 1,1 4,0 1,7 6,1 4,0 5,7 1354 47 (-1;-4) 1,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKD MaxINVISIVENT® EVO HR Basic 20 13489 10,6 38,2 15,9 57,2 17,9 16,0 12550 34 (0;-1) 2,0 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR BasicINVISIVENT® EVO HR High 21 9349 7,3 26,5 11,6 41,7 14,0 11,8 9765 39 (0;-1) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR HighINVISIVENT® EVO HR Ultra 22 7016 5,5 19,9 9,1 32,8 8,0 9,8 6919 42 (0;-2) 2,2 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO HR UltraINVISIVENT® EVO AKR33-module 23 11818 9,3 33,4 12,9 46,6 11,6 12,9 13000 33 (-1;-2) 3,6 yes yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO AKR33-moduleINVISIVENT® EVO UT 24 10092 7,9 28,6 12,3 44,2 30,7 33,6 9765 39 (0;-1) 2,2 as from 10 Pa yes 0 n.p.d. anodised / RAL / dual color 6000 INVISIVENT® EVO UTFlap ventilators glazed-in/at transom Flap ventilators glazed-in/at transomTC45 28 10435 8,2 29,5 11,5 41,4 25,8 36,5 11333 27 (0;0) 4,1 no no 45 20/24/28 anodised / RAL / dual color 2500 TC45TC60 30 15652 12,3 44,3 17,4 62,6 38,9 55,0 12314 28 (0;0) 3,3 no no 60 20/24/28 anodised / RAL / dual color 2500 TC60AR60 32 10427 8,2 29,5 11,8 42,3 19,7 23,9 14900 27 (0;0) 4,5 yes yes 60 20/24/28 anodised / RAL / dual color 2500 AR60THK60 32 11841 9,3 33,5 13,2 47,5 29,6 41,8 14841 27 (0;0) 4,5 no no 60 20/24/28 anodised / RAL / dual color 2500 THK60AR75 Small 34 14174 11,1 40,1 15,3 54,9 17,3 14,7 10762 26 (-1;-1) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 SmallAR75 Medium 34 17409 13,7 49,3 18,8 67,5 21,4 18,9 13531 26 (-1;-2) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 MediumAR75 Large 34 19034 15,0 53,9 22,6 81,3 24,5 21,7 16171 26 (-1;-2) 3,0 yes no 75/77 20/24/28/32/36*/40*/44* anodised / RAL / dual color 2500 AR75 LargeAR75 Xlarge 34 24301 19,1 68,8 29,0 104,3 31,5 28,0 18431 26 (-1;-1) 3,0 yes no 75/77 20/24/28/32/36* anodised / RAL / dual color 2500 AR75 XlargeAR90 36 14252 11,2 40,3 15,6 56,2 11,4 9,1 11070 30 (-1;-2) 3,9 yes no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) AR90THK90 36 14736 11,6 41,7 16,1 57,9 34,5 48,0 14120 28 (0;-1) 3,9 no no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) THK90THM90EVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24/28/33 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90EVO

THM90PBEVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24/28 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90PBEVO

THM90TREVO 38 11841 9,3 33,5 13,9 50,0 13,5 15,1 11200 26 (0;0) 3,8 yes no 90 20/24 anodised / RAL / dual color 2500 (2000 mm for motorised control) THM90TREVO

AK80EVO/1 40 n.p.d. 0,6 2,0 1,1 4,1 3,5 3,7 1280 47 (0;-3) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/1AK80EVO/2 40 n.p.d. 0,9 3,2 1,7 6,2 5,4 5,8 2080 44 (-1;-4) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/2AK80EVO/3 40 n.p.d. 1,3 4,7 2,1 7,5 6,6 6,3 2440 41 (-1;-3) 2,3 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/3AK80EVO/4 40 n.p.d. 4,1 14,8 6,6 23,6 20,5 19,6 5293 33 (-1;-2) 2,1 as from 8 Pa yes n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80EVO/4AK80/1 40 1488 1,2 4,2 1,6 5,9 3,6 5,0 1280 47 (0;-3) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/1AK80/2 40 2163 1,7 6,1 2,5 9,0 5,8 8,4 2080 44 (-1;-4) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/2AK80/3 40 2545 2,0 7,2 2,9 10,4 7,1 10,4 2440 41 (-1;-3) 2,3 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/3AK80/4 40 8780 6,9 24,8 9,7 34,9 21,1 29,6 6680 33 (-1;-2) 2,1 no no n.a. n.p.d. anodised / RAL / dual color 2000 (1250 mm for cord control) AK80/4AK80GL/1 42 1488 1,2 4,2 1,6 5,9 3,6 5,0 1280 47 (0;-3) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/1AK80GL/2 42 2163 1,7 6,1 2,5 9,0 5,8 8,4 2080 44 (-1;-4) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/2AK80GL/3 42 2545 2,0 7,2 2,9 10,4 7,1 10,4 2440 41 (-1;-3) 2,3 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/3AK80GL/4 42 8780 6,9 24,8 9,7 34,9 21,1 29,6 6680 33 (-1;-2) 2,1 no no 108 20/24/28/32/36 anodised / RAL / dual color 2000 (1250 mm for cord control) AK80GL/4SONOVENT® Small 10 44 17756 14,0 50,2 14,0 50,2 15,3 22,9 10000 46 (-1;-5) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 10SONOVENT® Small 15 44 29593 23,3 83,7 23,3 83,7 25,6 28,5 11000 41 (-1;-2) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 15SONOVENT® Small 20 44 31813 25,0 90,0 25,0 90,0 27,5 29,2 18900 40 (-1;-3) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 20SONOVENT® Small 25 44 33786 26,6 95,6 26,6 95,6 29,2 27,1 22300 37 (-1;-3) 4,5 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Small 25SONOVENT® Medium 10 44 17509 13,8 49,5 13,8 49,5 15,1 n.p.d. 10000 48 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 10SONOVENT® Medium 15 44 26511 20,8 75,0 20,8 75,0 22,9 n.p.d. 11000 45 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 15SONOVENT® Medium 20 44 33292 26,2 94,2 26,2 94,2 28,8 n.p.d. 18900 43 (0;-3) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 20SONOVENT® Medium 25 44 34032 26,7 96,3 26,7 96,3 29,4 27,5 22300 39 (-1;-4) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Medium 25SONOVENT® Large 10 44 16153 12,7 45,7 12,7 45,7 14,0 n.p.d. 10000 50 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 10SONOVENT® Large 15 44 25524 20,1 72,2 20,1 72,2 22,1 n.p.d. 11000 49 (-2;-7) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 15SONOVENT® Large 20 44 32059 25,2 90,7 25,2 90,7 27,7 n.p.d. 18900 44 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 20SONOVENT® Large 25 44 33416 26,3 94,5 26,3 94,5 28,9 25,0 22300 41 (-2;-6) 4,6 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® Large 25SONOVENT® XLarge 10 44 14427 11,3 40,8 11,3 40,8 12,5 n.p.d. 10000 56 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 10SONOVENT® XLarge 15 44 21578 17,0 61,0 17,0 61,0 18,7 n.p.d. 11000 53 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 15SONOVENT® XLarge 20 44 31073 24,4 87,9 24,4 87,9 26,9 n.p.d. 18900 46 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 20SONOVENT® XLarge 25 44 32676 25,7 92,4 25,7 92,4 28,2 n.p.d. 22300 45 (-2;-6) 4,7 yes no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® XLarge 25SONOVENT® Compact 10 48 15334 12,1 43,4 16,4 58,9 17,3 17,8 9500 36 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 10SONOVENT® Compact 13 48 19278 15,2 54,5 18,8 67,7 18,8 18,7 12500 35 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 13SONOVENT® Compact 15 48 24687 19,4 69,8 19,9 71,5 18,6 19,1 15000 33 (0;-1) 6,0 yes no 78 20/24/28/32/36 RAL / dual color 2000/2500*** SONOVENT® Compact 15SONOVENT® I Small 50 43520 34,2 123,1 48,2 173,5 107,8 152,4 35857 32 (-1;-3) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I SmallSONOVENT® I Medium 50 44029 34,6 124,6 48,7 175,3 107,1 150,5 35857 33 (-1;-3) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I MediumSONOVENT® I Large 50 43392 34,1 122,8 48,0 172,8 107,3 151,8 35857 35 (-1;-4) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I LargeSONOVENT® I Xlarge 50 43138 33,9 122,0 48,0 172,8 107,3 151,8 35857 36 (-1;-4) 5,2 no no 130/135 20/24/28/32** RAL / dual color 2000/2500*** SONOVENT® I XlargeFlap ventilators for conservatories Flap ventilators for conservatoriesOxyvent® 54 15058 11,8 42,6 16,7 60,2 37,4 52,9 19300 27 (-1;-2) 2,8 no no 210 28 - 86 (by steps of 2 mm) RAL / dual color 1500 Oxyvent®Acoustic ventilator for slant roofs Acoustic ventilator for slant roofsSONOVENT® D Small 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 37 (-1;-3) 4,5 yes no n.a n.a RAL / dual color 1000 SONOVENT® D SmallSONOVENT® D Medium 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 39 (-1;-4) 4,6 yes no n.a n.a RAL / dual color 1000 SONOVENT® D MediumSONOVENT® D Large 56 31070 24,4 87,9 28,0 100,8 30,8 34,8 22300 41 (-2;-6) 4,6 yes no n.a n.a RAL / dual color 1000 SONOVENT® D LargeRoller shutter flap ventilator Roller shutter flap ventilatorTransivent® 58 13748 10,8 38,9 15,2 54,6 20,1 19,9 16368 28 (-1;-2) 3,0 yes yes n.a. n.a. anodised / RAL 2200 (1500 mm for cord control) Transivent®Sliding vents Sliding ventsTHL100 60 16759 13,2 47,4 18,7 67,2 41,6 58,9 16200 22 (0;-1) 3,9 no no 129 15*/20/24/28 anodised / RAL / dual color 3500 THL100THL100V 60 12770 10,0 36,1 14,2 51,3 32,1 45,5 27950 22 (0;-1) 3,9 no no 129 15*/20/24/28 anodised / RAL / dual color 3500 THL100VT67 62 11224 8,8 31,8 12,7 45,7 28,5 40,2 16330 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T67T100 62 17326 13,6 49,0 19,5 70,3 43,8 61,9 25342 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T100T130 62 24589 19,3 69,6 27,7 99,8 62,1 87,9 38302 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T130T150 62 27992 22,0 79,2 31,9 114,8 71,5 101,0 45592 n.p.d. n.p.d. no no n.a. n.a. anodised / RAL / dual color 3500 T150TL67 64 10137 8,0 28,7 11,4 41,4 25,3 36,2 16330 n.p.d. n.p.d. no no 98 20 anodised / RAL / dual color 3500 TL67TL100 64 14198 11,2 40,2 16,0 57,5 35,8 50,6 25342 n.p.d. n.p.d. no no 129 4/20/24 anodised / RAL / dual color 3500 TL100TL100 PB 64 14198 11,2 40,2 16,0 57,5 35,8 50,6 25342 n.p.d. n.p.d. no no 129 20 anodised / RAL / dual color 3500 TL100 PBSlotvents SlotventsSonoslot®, 275 mm 71 1273 1,0 3,6 1,4 5,0 3,2 3,3 1256 38 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 275 Sonoslot®, 275 mmSonoslot®, 375 mm 71 1607 1,3 4,5 1,7 6,2 4,0 4,2 1885 37 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 375 Sonoslot®, 375 mmSonoslot®, 475 mm 71 2121 1,7 6,0 2,3 8,3 5,3 5,6 2513 36 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 475 Sonoslot®, 475 mmSonoslot®, 700 mm 71 3181 2,5 9,0 3,4 12,4 8,0 8,4 3769 34 (0;0) 1,4 yes yes n.a. n.a. anodised / Renson standard WHITE, 9005, 1247 700 Sonoslot®, 700 mmSonoslot® Max without damping 72 2298 1,8 6,5 2,7 9,7 6,8 6,9 1871 38 (-1;-2) n.p.d. yes no n.a. n.a. Renson standard WHITE / RAL 1247 700 Sonoslot® Max without dampingSonoslot® Max with damping 72 1555 1,2 4,4 1,9 6,8 5,1 7,6 1871 40 (-1;-2) n.p.d. yes no n.a. n.a. Renson standard WHITE / RAL 1247 700 Sonoslot® Max with dampingCombined ventilation and sun shading overframe Combined ventilation and sun shading overframeFixvent® Mono AKEVO See technical values on page 74-75 See technical values on page 74-75 Fixvent® Mono AKEVO

Airflow based upon aluminiumsize = 1000 mm (except slotvents)

Page 8: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

8

Invisivent® EVO < Overframe flap ventilators

The most discrete, self-regulating overframe flap ventilator

With the Invisivent EVO, RENSON has developed the most discrete self-regulating window ventilator in the world that combines a healthy living comfort with a maximum visual comfort.

Installation on top of the window frameThe Invisivent EVO is a thermally broken window ventilator that is instal-led on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

Page 9: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

9

Overframe flap ventilators > Invisivent® EVO

Section detail

Technical characteristics Invisivent® EVO

Airflow

Equivalent area 13728 mm²/m

Q at 1 Pa 10,8 l/s/m

Q at 1 Pa 38,8 m³/h/m

Q at 2 Pa 14,3 l/s/m

Q at 10 Pa 13,1 l/s/m

Q at 20 Pa 14,4 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 27 (-1;-1) dB

- in closed position 49 (-2;-4) dB

Technical characteristics

Controllable internal flap 6 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,8 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Min. 50 - max. 64 mm

29 m

m33

mm

Min. 80 - max. 94 mmMin. 65 - max. 79 mm

Min. 95 - max. 109 mm Min. 110 - max. 124 mm

Min. 140 - max. 154 mm Min. 155 - max. 169 mm

Min. 170 - max. 184 mm

Min. 125 - max. 139 mm

Page 10: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

10

Invisivent® EVO HF < Overframe flap ventilators

The most discrete, self-regulating overframe flap ventilator with higher airflow

The Invisivent EVO HF delivers 30% more airflow then the regular Invisivent EVO. This version of the Invisivent EVO has been specifically developed for use in spaces with small windows where sufficient airflow must be achieved, and is ideal for ensuring sufficient fresh air in rooms with high occupancy such as classrooms. In closed position there is no visual difference between the Invisivent EVO HF and Invisivent EVO, so both models can be used in the same building.

Installation on top of the window frameThe Invisivent EVO HF is a thermally broken window ventilator that is installed on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

30% more airflow than the regular Invisivent® EVO

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO HF ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

Page 11: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

11

Overframe flap ventilators > Invisivent® EVO HF

Technical characteristics Invisivent® EVO HF

Airflow

Equivalent area 17942 mm²/m

Q at 1 Pa 14,1 l/s/m

Q at 1 Pa 50,8 m³/h/m

Q at 2 Pa 18,5 l/s/m

Q at 10 Pa 16,5 l/s/m

Q at 20 Pa 18,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 28 (-1;-2) dB

- in closed position 49 (-2;-4) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,8 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

Section detail

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Min. 50 - max. 64 mm

29 m

m33

mm

Min. 80 - max. 94 mmMin. 65 - max. 79 mm

Min. 95 - max. 109 mm Min. 110 - max. 124 mm

Min. 140 - max. 154 mm Min. 155 - max. 169 mm

Min. 170 - max. 184 mm

Min. 125 - max. 139 mm

Page 12: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

12

Invisivent® EVO AK < Acoustic overframe flap ventilators

The most discrete, self-regulating and sound-absorbing overframe flap ventilator

The Invisivent EVO AK is the acoustic version of the Invisivent EVO. Four different Invisivent EVO AK versions are available (Basic, High, Ultra or Extreme), each representing a different level of sound reduction. For each specific window frame depth, a different PVC profile is used (and special extension profiles are used for some window frame depths) in order to make the Invisivent EVO AK fit perfectly to the window profile.

Window depth <110 mm: Invisivent EVO AK Basic + special extension profile (>110 mm, an adapted PVC interior profile is used)Window depth < 140 mm: Invisivent EVO AK High / Ultra / Extreme + special extension profile (>140 mm, an adapted PVC interior profile is used)

Installation on top of the window frameThe Invisivent EVO AK is a thermally broken window ventilator that is installed on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO AK ensures the supply of fresh and healthy air without draughts (Invisivent EVO AK Extreme is not self-regulating). Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Sound absorbingIn open position: Invisivent EVO AK Basic: 34 (0;-1) dB Invisivent EVO AK High: 39 (0;-1) dB Invisivent EVO AK Ultra: 42 (0;-2) dB Invisivent EVO AK Extreme: 48 (0;-2) dB

Removable acoustic foam

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

RE

MO

VA

B L E A C OUST I C F O

AM

Page 13: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

13

Acoustic overframe flap ventilators > Invisivent® EVO AK Basic

Section detail Invisivent® EVO AK BASIC

Technical characteristics Invisivent® EVO AK Basic

Airflow

Equivalent area 13489 mm²/m

Q at 1 Pa 10,6 l/s/m

Q at 1 Pa 38,2 m³/h/m

Q at 2 Pa 15,9 l/s/m

Q at 10 Pa 17,9 l/s/m

Q at 20 Pa 16,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 34 (0;-1) dB

- in closed position 57 (-1;-4) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,0 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

2933

60Min. 50 - max. 64 45

Min. 65 - max. 79 30

Min. 80 - max. 94

15Min. 95 - max. 109

Min. 140 - max. 154

Min. 170 - max. 184

Min. 110 - max. 124

Min. 155 - max. 169

Min. 125 - max. 139

Page 14: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

14

Invisivent® EVO AK High < Acoustic overframe flap ventilators

Section detail Invisivent® EVO AK HIGH

Technical characteristics Invisivent® EVO AK High

Airflow

Equivalent area 9349 mm²/m

Q at 1 Pa 7,3 l/s/m

Q at 1 Pa 26,5 m³/h/m

Q at 2 Pa 11,6 l/s/m

Q at 10 Pa 14,0 l/s/m

Q at 20 Pa 11,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 39 (0;-1) dB

- in closed position 62 (-2;-6) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

2933

90Min. 50 - max. 64 75

Min. 65 - max. 79 60

Min. 80 - max. 94

Min. 140 - max. 154

Min. 170 - max. 184

Min. 155 - max. 169

45 30 15Min. 95 - max. 109 Min. 110 - max. 124 Min. 125 - max. 139

Page 15: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

15

Acoustic overframe flap ventilators > Invisivent® EVO AK Ultra

Section detail Invisivent® EVO AK Ultra

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Technical characteristics Invisivent® EVO AK Ultra

Airflow

Equivalent area 7016 mm²/m

Q at 1 Pa 5,5 l/s/m

Q at 1 Pa 19,9 m³/h/m

Q at 2 Pa 9,1 l/s/m

Q at 10 Pa 8,0 l/s/m

Q at 20 Pa 9,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 42 (0;-2) dB

- in closed position 64 (-1;-4) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

2933

90Min. 50 - max. 64 75

Min. 65 - max. 79 60

Min. 80 - max. 94

45Min. 95 - max. 109 30Min. 110 - max. 124 15Min. 125 - max. 139

Min. 140 - max. 154 Min. 155 - max. 169

Min. 170 - max. 184

Page 16: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

16

Section detail Invisivent® EVO AK Extreme

Attention: Invisivent® EVO AK Extreme is visually identical to the Invisivent® EVO AK High and Invisivent® EVO UT, but is not self-regulating!

Technical characteristics Invisivent® EVO AK Extreme

Airflow

Equivalent area 2404 mm²/m

Q at 1 Pa 1,9 l/s/m

Q at 1 Pa 6,8 m³/h/m

Q at 2 Pa 2,8 l/s/m

Q at 10 Pa 6,4 l/s/m

Q at 20 Pa 9,3 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 48 (0;-2) dB

- in closed position 64 (-4;-11) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 1,7 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Invisivent® EVO AK Extreme < Acoustic overframe flap ventilators29

33

Min. 50 - max. 64

Min. 65 - max. 79

Min. 80 - max. 94

Min. 140 - max. 154

Min. 170 - max. 184

Min. 155 - max. 169

Min. 95 - max. 109 Min. 110 - max. 124 Min. 125 - max. 139

90 75 60

45 30 15

Page 17: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

17

Acoustic overframe flap ventilators > Invisivent® EVO AKD (Max)

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

RE

MO

VA

B L E A C OUST I C F O

AM

The most discrete, self-regulating and superior sound absorbing overframe ventilator

The Invisivent EVO AKD (Max) is a sound absorbing, self-regulating and thermally broken window ventilator that is installed on top of the win-dow frame. This acoustic version of the Invisivent EVO combines a healthy living comfort with a maximum visual comfort, without losing any acoustic comfort.

Compared to the Invisivent EVO AK-series, this Invisivent EVO AKD (Max) has a much better acoustic performance thanks to the extra outer profile. Two different types are available: the Invisivent EVO AKD and the Invisivent EVO AKD Max – the latter with an even better acoustic perfor-mance than the first.

For each specific window frame depth, a different PVC profile is used (and special extension profiles are used for some window frame depths) in order to make the Invisivent EVO AKD (Max) fit perfectly to the window profile.

Installation on top of the window frameThe Invisivent EVO AKD (Max) is a thermally broken window ventilator that is installed on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO AKD (Max) ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Sound absorbingInvisivent EVO AKD: 39 (0;-2) dB in open positionInvisivent EVO AKD Max: 47 (-1;-4) dB in open position

Removable acoustic foam

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

Page 18: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

18

Invisivent® EVO AKD (Max) < Acoustic overframe flap ventilators

Technical characteristics Invisivent® EVO AKD Invisivent® EVO AKD-Max

Airflow

Equivalent area 4961 mm²/m 1400 mm²/m

Q at 1 Pa 3,9 l/s/m 1,1 l/s/m

Q at 1 Pa 14,0 m³/h/m 4,0 m³/h/m

Q at 2 Pa 5,6 l/s/m 1,7 l/s/m

Q at 10 Pa 13,3 l/s/m 4,0 l/s/m

Q at 20 Pa 19,3 l/s/m 5,7 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 39 (0;-2) dB 47 (-1;-4) dB

- in closed position 60 (-1;-4) dB 63 (-1;-4) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 1,2 W/m²K (as from window depth 140 mm: 1,0 W/m²K)

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 63 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

Section detail

45 mm

EC= 50 mm

EC= 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

35

60Min. 50 - max. 64

28

63

15Min. 95 - max. 109

45Min. 65 - max. 79 30

Min. 80 - max. 94

Min. 110 - max. 124 Min. 125 - max. 139

Min. 140 - max. 154

Min. 170 - max. 184

Min. 155 - max. 169

Page 19: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

19

Acoustic overframe flap ventilators > Invisivent® EVO HR

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

RE

MO

VA

B L E A C OUST I C F O

AM

The most discrete, self-regulating and sound-absorbing overframe flap ventilator for high rise applications

The new Invisivent EVO HR provides the ideal solution for wind-impacted applications such as high-rise buildings and apartment buildings on the coast.The Invisivent EVO HR contains acoustic material, that muffles external noises as much as possible (e.g. wind, seagulls, traffic), which increases user comfort. The presence of various types of sound damping foam in the inside profile provides 3 possible levels of sound insulation (Basic, High or Ultra). In addition to that, the rain cap, which is mounted as standard, ensures perfect water-resistance in even the most extreme conditions. Extra mounting screws and clips guarantee satisfactory sta-bility and sturdiness of the entire window.The unique Invisivent EVO HR combines its functionality with maximum respect for the architecture since it can be positioned on the window frame, behind the wall. Ideal for wind impacted applications (coast and high rise building situations)

Installation on top of the window frameThe Invisivent EVO HR is a thermally broken window ventilator that is installed on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO HR ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Sound absorbingIn open position: Invisivent EVO HR Basic: 34 (0;-1) dB Invisivent EVO HR High: 39 (0;-1) dB Invisivent EVO HR Ultra: 42 (0;-2) dB

Removable acoustic foam

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

Page 20: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

20

Invisivent® EVO HR Basic < Acoustic overframe flap ventilators

Section detail Invisivent® EVO HR Basic

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Technical characteristics Invisivent® EVO HR Basic

Airflow

Equivalent area 13489 mm²/m

Q at 1 Pa 10,6 l/s/m

Q at 1 Pa 38,2 m³/h/m

Q at 2 Pa 15,9 l/s/m

Q at 10 Pa 17,9 l/s/m

Q at 20 Pa 16,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 34 (0;-1) dB

- in closed position 57 (-1;-4) dB

Technical characteristics

Controllable internal flap 16 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,0 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 1200 Pa

Watertightness in open position, up to 250 Pa

Dimensions

Glass reduction 0 mm

Height 65 mm

Depths window frame 50 up to 184 mm (or more upon request)

Max. length 6000 mm

2936

Min. 50 - max. 64 6027

Min. 65 - max. 79 4527 3027 Min. 80 - max. 94

1527 Min. 95 - max. 109 27 Min. 110 - max. 124 27 Min. 125 - max. 139

27 Min. 140 - max. 154 27 Min. 155 - max. 169

27 Min. 170 - max. 184

Page 21: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

21

Acoustic overframe flap ventilators > Invisivent® EVO HR High

Section detail Invisivent® EVO HR High

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Technical characteristics Invisivent® EVO HR High

Airflow

Equivalent area 9349 mm²/m

Q at 1 Pa 7,3 l/s/m

Q at 1 Pa 26,5 m³/h/m

Q at 2 Pa 11,6 l/s/m

Q at 10 Pa 14,0 l/s/m

Q at 20 Pa 11,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 39 (0;-1) dB

- in closed position 62 (-2;-6) dB

Technical characteristics

Controllable internal flap 16 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 1200 Pa

Watertightness in open position, up to 250 Pa

Dimensions

Glass reduction 0 mm

Height 65 mm

Depths window frame 50 up to 184 mm(or more upon request)

Max. length 6000 mm

2936

Min. 50 - max. 64 9027

Min. 65 - max. 79 7527 6027 Min. 80 - max. 94

4527 Min. 95 - max. 109

27 Min. 140 - max. 154 27 Min. 155 - max. 169

27 Min. 170 - max. 184

3027 Min. 110 - max. 124 1527 Min. 125 - max. 139

Page 22: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

22

Invisivent® EVO HR Ultra < Acoustic overframe flap ventilators

Section detail Invisivent® EVO HR Ultra

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

Technical characteristics Invisivent® EVO HR Ultra

Airflow

Equivalent area 7016 mm²/m

Q at 1 Pa 5,5 l/s/m

Q at 1 Pa 19,9 m³/h/m

Q at 2 Pa 9,1 l/s/m

Q at 10 Pa 8,0 l/s/m

Q at 20 Pa 9,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 42 (0;-2) dB

- in closed position 64 (-1;-4) dB

Technical characteristics

Controllable internal flap 16 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 1200 Pa

Watertightness in open position, up to 250 Pa

Dimensions

Glass reduction 0 mm

Height 65 mm

Depths window frame 50 up to 184 mm(or more upon request)

Max. length 6000 mm

2936

Min. 50 - max. 64 9027

Min. 65 - max. 79 7527 6027 Min. 80 - max. 94

27 Min. 140 - max. 154 27 Min. 155 - max. 169

27 Min. 170 - max. 184

4527 Min. 95 - max. 109 3027 Min. 110 - max. 124 1527 Min. 125 - max. 139

Page 23: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

23

Acoustic overframe flap ventilators > AKR33-module

Acoustic retrofit module for the Invisivent®EVO

Over the years, one’s neighbourhood can change dramatically, with for example increasing traffic leading to increasing noise pollution. With the AKR33-module it is possible to upgrade one’s previously installed Invisivent EVO with a minimal sound absorbing module, so that one can enjoy his home again in all comfort.

Acoustic retrofit moduleRENSON has developed a special acoustic retrofit module that can easily be clicked on a previously installed Invisivent EVO.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO AKR33-module ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Sound absorbingInvisivent EVO + AKR33-module: 33 (-1;-2) dB in open position

Available in the same color as the Invisivent® EVO

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

Technical characteristics AKR33-module

Airflow

Equivalent area 11818 mm²/m

Q at 1 Pa 9,3 l/s/m

Q at 1 Pa 33,4 m³/h/m

Q at 2 Pa 12,9 l/s/m

Q at 10 Pa 11,6 l/s/m

Q at 20 Pa 12,9 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 33 (-1;-2) dB

- in closed position 46 (0;-2) dB

Technical characteristics

Controllable internal flap 6 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 3,6 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

T

HE

R

MA L L Y B R O

KE

N

Installation1. Remove the aluminium interior profile

from the Invisivent EVO

2. Click the acoustic AKR33-module onto the PVC-profile of the Invisivent EVO

3. Insert the aluminium interior profile from the Invisivent EVO on the acoustic AKR33-module

Page 24: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

24

Invisivent® EVO UT < Acoustic overframe flap ventilators

The most discrete, self-regulating and sound-absorbing overframe flap ventilator for utility buildings

The Invisivent EVO UT is the acoustic version of the Invisivent EVO that has been especially developed for utility buildings. Its self-regulating flap only starts working at a wind pressure of 10 Pa (instead of at 2 Pa as for the other Invisivent EVO vents), ensuring a constant higher level of basic ventilation. This type of window ventilation is only suitable for utility applications in which both the natural supply and mechanical extrac-tion are located in the same room.

Window depth < 140 mm: Invisivent EVO UT + special extension profile (>140 mm, an adapted PVC interior profile is used)

Utility buildings

Installation on top of the window frameThe Invisivent EVO UT is a thermally broken window ventilator that is installed on top of the aluminium, timber or PVC window frame. This almost invisible installation guarantees maximum light penetration as the glass size is not reduced.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Invisivent EVO UT ensures the supply of fresh and healthy air without draughts. The self-regulating flap only starts working at a wind pressure of 10 Pa (instead of at 2 Pa). Moreover, the interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Sound absorbingInvisivent EVO UT: 39 (0;-1) dB in open position

Removable acoustic foam

Insect mesh

Burglar proofThe Invisivent EVO range meets the requirements of burglary resistance class 2 according to standard prEN 1627 to 1630, and therefore suits to be used on a window class WK2.

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N i -F lux ®

as from

10 Pa

RE

MO

VA

B L E A C OUST I C F O

AM

Page 25: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

25

Acoustic overframe flap ventilators > Invisivent® EVO UT

Section detail Invisivent® EVO UT

Technical characteristics Invisivent® EVO UT

Airflow

Equivalent area 10092 mm²/m

Q at 1 Pa 7,9 l/s/m

Q at 1 Pa 28,6 m³/h/m

Q at 2 Pa 12,3 l/s/m

Q at 10 Pa 30,7 l/s/m

Q at 20 Pa 33,6 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 39 (0;-1) dB

- in closed position 62 (-2;-6) dB

Technical characteristics

Controllable internal flap 5 stepped position

Control options internal flap Manual, cord, rod, motor

U value 2,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 900 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 0 mm

Height 62 mm

Depths window frame 50 up to 184 mm(or more upon request)

Max. length 6000 mm

45 mm

EC = 50 mm EC = 50 mmT (= cutting size) = T - 100 mm

T (= glass size)

2933

Min. 50 - max. 64 90

Min. 65 - max. 79 75 60Min. 80 - max. 94

45Min. 95 - max. 109

Min. 140 - max. 154 Min. 155 - max. 169

Min. 170 - max. 184

30Min. 110 - max. 124 15Min. 125 - max. 139

Page 26: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

26

Finishing profileThe Invisivent EVO is designed to provide a perfect finish. There is a cut-out at the top of the vent that takes plasterboard or MDF panels up to 10 mm thick, and which allows the plasterer to integrate the vent discreetly into the plastered surface.The optional aluminium finishing profile should be used with traditional wet plastering. The profile should also be used for a perfect finish when installing a roller shutter box, for example, above the Invisivent EVO. This profile is available in the same finish as the inside of the Invisivent EVO.

Invisivent® EVO range < Options

Control flapFor ease of use or at the customer’s request, the control flap is split up for lengths above 3500 mm. A special middle piece (3 mm thick) is inserted between the two flaps to give a neat finish.

Installation using wall bracketsThe Invisivent EVO has a dowel slot so it can be attached quickly and easily to the unfinished structure by using wall brackets.

Split up middle pieceAn Invisivent EVO is available in lengths up to 6 meter. However, it is also possible to install several Invisivent EVO vents next to each other, joined by a split up middle piece for a perfect finish.

Page 27: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

27

Options > Invisivent® EVO range

Airflow limitersAirflow limiters can easily be clipped into the Invisivent EVO. They close the opening by 100 mm so that the maximum flow can be adjusted to suit your needs.

Rain capIn case of exposure to extreme weather conditions (rain, sand, high wind loads,..), a rain cap can be added to the Invisivent EVO, ensuring high comfort at all times.

Side mounting plateThe use of side mounting plates is recommended to ensure that the Invisivent EVO fits securely to the window.

Removable acoustic foamThe acoustic foam can be removed (and cleaned or substituted) from the Invisivent EVO through the perforated PVC profile.

“Permanently open” clipIf required, the Invisivent EVO can be supplied with a special clip to keep the unit permanently open (e.g. for open gas appliances). This clip can also be retrofitted.

Page 28: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

28

TC45 < Flap ventilators glazed-in/at transom

Compact flap vent with a good price/quality ratio

The compact TC45 is a non-selfregulating, thermally broken aluminium glazed-in window vent with a soft-line design outer profile. The internal flap directs the incoming airflow upwards and can be placed in 5 positi-ons.

Glazed-in installation (or at transom)The TC45 can be installed glazed-in, or at transom using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

Coanda effectThe interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

CO

AN D A - E F F E

CT

Page 29: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

29

Flap ventilators glazed-in/at transom > TC45

Section detail

Technical characteristics TC45

Airflow

Equivalent area 10435 mm²/m

Q at 1 Pa 8,2 l/s/m

Q at 1 Pa 29,5 m³/h/m

Q at 2 Pa 11,5 l/s/m

Q at 10 Pa 25,8 l/s/m

Q at 20 Pa 36,5 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 27 (0;0) dB

- in closed position 37 (-1;-2) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod

U value 4,1 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to n.p.d.

Dimensions

Glass reduction 45 mm

Height 60 mm

Glass thickness 20, 24 or 28 mm

Max. length 2500 mm

2023.7 23.667.3

26

6045

15

2423.7 23.671.3

30

6045

15

2823.7 23.675.3

34

6045

15

Y = glass width

Y - (48 mm)

24 mm 24 mm

Page 30: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

30

TC60 < Flap ventilators glazed-in/at transom

Compact flap vent with an excellent price/quality ratio

The TC60 is a non-selfregulating, thermally broken aluminium glazed-in window vent with a soft-line design outer profile, having an excel-lent price/quality ratio. The internal flap directs the incoming airflow upwards and can be continuously controlled.

Glazed-in installation (or at transom)The TC60 has been developed for glazed-in installation, and can be in-tegrated in aluminium, timber and PVC window profiles with a depth of 20, 24 or 28 mm. The TC60 can optionally also be installed at transom, using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

Excellent price/quality ratio

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

Page 31: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

31

Flap ventilators glazed-in/at transom > TC60

Section detail

2021.3

45.9

26

75

60

19

2421.3

49.9

30

75

60

19

2821.3

53.9

34

75

60

19

Technical characteristics TC60

Airflow

Equivalent area 15652 mm²/m

Q at 1 Pa 12,3 l/s/m

Q at 1 Pa 44,3 m³/h/m

Q at 2 Pa 17,4 l/s/m

Q at 10 Pa 38,9 l/s/m

Q at 20 Pa 55,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 28 (0;0) dB

- in closed position 42 (0;0) dB

Technical characteristics

Controllable internal flap continuous adjustment

Control options internal flap Manual, cord, rod

U value 3,3 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 10 Pa

Dimensions

Glass reduction 60 mm

Height 75 mm

Glass thickness 20, 24 or 28 mm

Max. length 2500 mm

Y = glass width

Y - (78 mm)39 mm 39 mm

Page 32: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

32

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

AR60-THK60 < Flap ventilators glazed-in/at transom

AR60: Self-regulating flap vent with external hood for improved weather protection

The interior profile of the AR60 deflects the incoming air upwards so that fresh air is optimally spread in the room. It also has an external hood for additional weather protection.The AR60 is also available with permanently open clips (e.g. for open gas appliances).

Glazed-in installation (or at transom)The AR60 has been developed for glazed-in installation, and can be in-tegrated in aluminium, timber and PVC window profiles with a depth of 20, 24 or 28 mm. The AR60 can optionally also be installed at transom, using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the AR60 ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Insect mesh

THK60: Flap vent with external hood for improved weather protection

The THK60 is a thermally broken, slimline glazed-in ventilator for ap-plication in aluminium, timber and PVC windows. The internal tip directs the flow of incoming air upwards, and can be placed in 5 positions.The THK60 is also available with permanently open clips (e.g. for open gas appliances).

Glazed-in installation (or at transom)The THK60 has been developed for glazed-in installation, and can be integrated in aluminium, timber and PVC window profiles with a depth of 20, 24 or 28 mm. The THK60 can optionally also be installed at tran-som, using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

Coanda-effectThe interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

A

T T R A N S O

M

CO

AN D A - E F F E

CT

Page 33: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

33

Flap ventilators glazed-in/at transom > AR60-THK60

Technical characteristics AR60 THK60

Airflow

Equivalent area 10427 mm²/m 11841 mm²/m

Q at 1 Pa 8,2 l/s/m 9,3 l/s/m

Q at 1 Pa 29,5 m³/h/m 33,5 m³/h/m

Q at 2 Pa 11,8 l/s/m 13,2 l/s/m

Q at 10 Pa 19,7 l/s/m 29,6 l/s/m

Q at 20 Pa 23,9 l/s/m 41,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 27 (0;0) dB 27 (0;0) dB

- in closed position 44 (0;0) dB 44 (0;0) dB

Technical characteristics

Controllable internal flap 5 stepped positions 5 stepped positions

Control options internal flap Manual, cord, rod Manual, cord, rod

U value 4,5 W/m²K 4,5 W/m²K

Air leakage at 50 Pa <15% (in closed position) <15% (in closed position)

Watertightness in closed position, up to 650 Pa 650 Pa

Watertightness in open position, up to 100 Pa 50 Pa

Dimensions

Glass reduction 60 mm 60 mm

Height 76 mm 76 mm

Glass thickness 20, 24 or 28 mm 20, 24 or 28 mm

Max. length 2500 mm 2500 mm

Section detail

THK60

2028.75 19.468.15

20

6016

26

24

76

2428.75 19.472.15

24

6016

30

24

76

2828.75 19.476.15

28

6016

34

24

76

AR60

2028.75 19.468.15

20

6016

26

24

76

2428.75 19.472.15

24

6016

30

24

76

2828.75 19.476.15

28

6016

34

24

76

Endcap size = 33 mm

Endcap size = 33 mm

Page 34: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

34

AR75 < Flap ventilators glazed-in/at transom

Excellent self-regulating window vent with 4 different airflows in 1 design

Due to its unique patented inner mechanism, 4 different airflow levels can be reached while the AR75 visually maintains the same look.

Glazed-in installation (or at transom)The AR75 has been developed for glazed-in installation, and can be inte-grated in aluminium, timber and PVC window profiles. This vent can also be installed at transom using an additional transom profile.

Thermally brokenNo cold air transfer from outside to inside.

Self-regulatingThanks to its self-regulating flap, the AR75 ensures the supply of fresh and healthy air without draughts.

4 different airflow levels with 1 single designDue to its internal mechanism, the AR75 can obtain 4 different airflow levels. This allows to use the same vent (visually) in order to provide dif-ferent rooms, each with their specific ventilation needs, with fresh air.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

A

T T R A N S O

M

Page 35: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

35

Flap ventilators glazed-in/at transom > AR75

Technical characteristics Small Medium Large Xlarge

Airflow

Equivalent area 14174 mm²/m 17409 mm²/m 19034 mm²/m 24301 mm²/m

Q at 1 Pa 11,1 l/s/m 13,7 l/s/m 15,0 l/s/m 19,1 l/s/m

Q at 1 Pa 40,1 m³/h/m 49,3 m³/h/m 53,9 m³/h/m 68,8 m³/h/m

Q at 2 Pa 15,3 l/s/m 18,8 l/s/m 22,6 l/s/m 29,0 l/s/m

Q at 10 Pa 17,3 l/s/m 21,4 l/s/m 24,5 l/s/m 31,5 l/s/m

Q at 20 Pa 14,7 l/s/m 18,9 l/s/m 21,7 l/s/m 28,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 26 (-1;-1) dB 26 (-1;-2) dB 26 (-1;-2) dB 26 (-1;-1) dB

- in closed position 43 (-1;-1) dB 43 (-1;-1) dB 43 (-1;-1) dB 43 (-1;-1) dB

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, cord, rod, motor

U value 3,0 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 75 mm (glass thickness: 20, 24, 28, and 32 mm) / 77 mm (glass thickness: 36, 40 and 44 mm)

Height 92 mm

Glass thickness 20, 24, 28, 32, 36*, 40*, 44* mm 20, 24, 28, 32, 36* mm

Max. length 2500 mm

* not for installation at transom

Section detail

42 mm 42 mmY - (2 x 42 mm)

Y

43 20 27.5

43.3

26

90.5

106.3

75

92

43 24 23.5

39.3

30

90.5

106.3

75

92

43 28 19.5

35.3

34

90.5

106.3

75

92

43 32 15.5

31.3

38

90.5

106.3

75

92

39 36 15.8

31

42

90.5

106.3

77

92

35 40 15.8

31

46

90.5

106.3

77

92

31 44 15.8

31

50

90.5

106.3

77

92

Page 36: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

36

AR90-THK90 < Flap ventilators glazed-in/at transom

Self-regulating flap vent with external hood for improved weather protection

The AR90 is the self-regulating version of the THK90. A self-regulating flap is integrated, reacting automatically to various wind pressures and thus preventing draughts. As the THK90, the AR90 has an external hood for additional weather protection.

Glazed-in installation (or at transom)The AR90 has been developed for glazed-in installation, and can be in-tegrated in aluminium, timber and PVC window profiles with a depth of 20, 24 or 28 mm. The AR90 can optionally also be installed at transom, using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

Self-regulatingThanks to its self-regulating flap, the AR90 ensures the supply of fresh and healthy air without draughts. Flat interior profileThanks to its flat interior profile, the AR90 is the ideal solution for inte-gration in the fixed part of sash windows.

Insect mesh

Flap vent with external hood for improved weather protection

The non self-regulating THK90 has a flat interior profile, which makes it a good solution for the integration in the fixed part of sash windows. The THK90 also has an external hood for additional weather protection.

Glazed-in installation (or at transom)The THK90 has been developed for glazed-in installation, and can be integrated in aluminium, timber and PVC window profiles with a depth of 20, 24 or 28 mm. The THK90 can optionally also be installed at tran-som, using the additional transom profiles.

Thermally brokenNo cold air transfer from outside to inside.

Flat interior profileThanks to its flat interior profile, the THK90 is a good solution for inte-gration in the fixed part of sash windows.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

A

T T R A N S O

M

Page 37: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

37

Flap ventilators glazed-in/at transom > AR90-THK90

Technical characteristics AR90 THK90

Airflow

Equivalent area 14252 mm²/m 14736 mm²/m

Q at 1 Pa 11,2 l/s/m 11,6 l/s/m

Q at 1 Pa 40,3 m³/h/m 41,7 m³/h/m

Q at 2 Pa 15,6 l/s/m 16,1 l/s/m

Q at 10 Pa 11,4 l/s/m 34,5 l/s/m

Q at 20 Pa 9,1 l/s/m 48,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 30 (-1;-2) dB 28 (0;-1) dB

- in closed position 45 (-1;-3) dB 44 (0;-1) dB

Technical characteristics

Controllable internal flap 5 posities 5 posities

Control options internal flap Manual, cord, rod, motor Manual, cord, rod, motor

U value 3,9 W/m²K 3,9 W/m²K

Air leakage at 50 Pa <15% (in closed position) <15% (in closed position)

Watertightness in closed position, up to 650 Pa 650 Pa

Watertightness in open position, up to 100 Pa 50 Pa

Dimensions

Glass reduction 90 mm 90 mm

Height 105 mm 105 mm

Glass thickness 20, 24 or 28 mm 20, 24 or 28 mm

Max. length 2500 mm (2000 mm for motorised control) 2500 mm (2000 mm for motorised control)

Section detail

THK9020

26

18

10590

15

51.4

24

30

18

10590

15

55.4

28

34

18

10590

15

58.9

AR90

20

20

18

105

9015

26

26.4 5

51.4

28

28

18

105

9015

34

26.4 4.5

58.9

24

24

18

105

9015

30

26.4 5

55.4

a = 17 a = 17

b = 44b = 44 c = cutting size

d = glass size

Page 38: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

38

THM90EVO/THM90PBEVO/THM90TREVO < Flap ventilators glazed-in/at transom

Self-regulating flush window vent, ideal for sliding doors

The THM90EVO is an entirely flat window vent, which makes this the ideal product for integration in sliding doors. Three different types of THM90EVO are available, each for different glass thicknesses: THM90EVO for glazed-in installation, THM90PBEVO for installation at the bottom of the window, and the THM90TREVO for installation between profiles (at transom).By combining a THM90PBEVO in the lower part and a THM90EVO in the upper part of a conservatory, the THM90EVO is ideal for natural ventila-tion by convection.

Glazed-in installation (or at transom)The THM90EVO has been developed for glazed-in installation, and can be integrated in aluminium, timber and PVC window profiles. The THM90EVO can be installed on glass, at the bottom of the window (THM90PBEVO), and at transom (THM90TREVO). The THM90EVO should only be used for installation on ground floors.

Thermally brokenNo cold air transfer from outside to inside.

Self-regulatingThanks to its self-regulating flap, the THM90EVO ensures the supply of fresh and healthy air without draughts.

Entirely flat profilesThanks to its flat profiles, the THM90EVO is the perfect solution for inte-gration in sash windows.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

A

T T R A N S O

M

Page 39: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

39

Flap ventilators glazed-in/at transom > THM90EVO/THM90PBEVO/THM90TREVO

Section detail

Technical characteristics THM90EVO – THM90PBEVO – THM90TREVO

Airflow

Equivalent area 11841 mm²/m

Q at 1 Pa 9,3 l/s/m

Q at 1 Pa 33,5 m³/h/m

Q at 2 Pa 13,9 l/s/m

Q at 10 Pa 13,5 l/s/m

Q at 20 Pa 15,1 l/s/m

Comfort

Sound reduction Dn,e,w

(C;Ctr)

- In open positie 26 (0;0) dB

- In gesloten positie 45 (-1;-1) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 3,8 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 100 Pa

Dimensions

Glass reduction 90 mm

Height 105 mm

Glass thickness

THM90EVO 20, 24, 28 or 33 mm

THM90PBEVO 20, 24 or 28 mm

THM90TREVO 20 or 24 mm

Max. length2500 mm

(2000 mm for motorised control)

THM90EVO

THM90PBEVO THM90TREVO

26

20

15

105

90

15

30

24

105

90

34

28

15

105

90

20

2015

105

9015

24

24

15

105

9015

20

26

90

105

15

24

30

90

105

15

28

34

90

105

15

33

38

90

105

15

Z 43,5 mm43,5 mm

Page 40: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

40

AK80EVO - AK80 < Acoustic flap ventilators glazed-in/at transom

T

HE

R

MA L L Y B R O

KE

N i -F lux ®

as from

8 Pa

A

T T R A N S O

M

AK80EVO: Compact, self-regulating acoustic window vent for installation at transom

The AK80EVO is a thermally broken acoustic vent with a pleasing com-pact design. This ventilator is the self-regulating version of the AK80, and therefore ensures the supply of fresh and healthy air without any draughts.Four different types are developed, each with their specific airflow and sound absorption. The AK80EVO, which has a high isolation value, is typically installed at transom and suits for all window types (aluminium, wood, PVC).

Installation at transom The AK80EVO should preferably be installed at transom, and is applicable for aluminium, timber and PVC window frame types.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the AK80EVO ensures the supply of fresh and healthy air without draughts. The self-regulating flap only starts working at wind pressure of 8 Pa (instead of at 2 Pa). Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Sound absorbingVarious sound reduction levels (depending on the type), from 33 (-1;-2) dB up to 47 (0;-3)dB in open position.

Insect mesh

AK80: Compact non self-regulating acoustic window vent for installation at transom

The AK80 is a thermally broken acoustic vent with a pleasing compact design. Four different types are developed, each with their specific air-flow and sound absorption. The AK80 is typically installed at transom.

Installation at transomThe AK80 should preferably be installed at transom, and is applicable for aluminium, timber and PVC window frame types.

Thermally brokenNo cold air transfer from outside to inside.

Coanda effectThe interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Sound absorbingVarious sound reduction levels (depending on the type), from 33 (-1;-2) dB up to 47 (0;-3) dB in open position.

Insect mesh

A

T T R A N S O

M

T

HE

R

MA L L Y B R O

KE

N

CO

AN D A - E F F E

CT

Page 41: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

41

Acoustic flap ventilators glazed-in/at transoms > AK80EVO - AK80

Section detail

Technical characteristics AK80EVO /1 AK80EVO /2 AK80EVO /3 AK80EVO /4

Airflow

Equivalent area n.p.d. n.p.d. n.p.d. n.p.d.

Q at 1 Pa 0,6 l/s/m 0,9 l/s/m 1,3 l/s/m 4,1 l/s/m

Q at 1 Pa 2,0 m3/h/m 3,2 m3/h/m 4,7 m3/h/m 19,8 m3/h/m

Q at 2 Pa 1,1 l/s/m 1,7 l/s/m 2,1 l/s/m 6,6 l/s/m

Q at 10 Pa 3,5 l/s/m 5,4 l/s/m 6,6 l/s/m 20,5 l/s/m

Q at 20 Pa 3,7 l/s/m 5,8 l/s/m 6,3 l/s/m 19,6 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 47 (0;-3) dB 44 (-1;-4) dB 41 (-1;-3) dB 33 (-1;-2) dB

- in closed position 51 (-1;-3) n.p.d. n.p.d. n.p.d.

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,3 W/m²K 2,3 W/m²K 2,3 W/m²K 2,1 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Height 80 mm (box height) / 126 mm (total height with flanges)

Max. length 2000 mm (1250 mm for cord control)

86

3

2020

40

25 - 57AK80EVO AK80

Technical characteristics AK80/1 AK80/2 AK80/3 AK80/4

Airflow

Equivalent area 1488 mm2/m 2163 mm2/m 2545 mm2/m 8780 mm2/m

Q at 1 Pa 1,2 l/s/m 1,7 l/s/m 2,0 l/s/m 6,9 l/s/m

Q at 1 Pa 4,2 m3/h/m 6,1 m3/h/m 7,2 m3/h/m 24,8 m3/h/m

Q at 2 Pa 1,6 l/s/m 2,5 l/s/m 2,9 l/s/m 9,7 l/s/m

Q at 10 Pa 3,6 l/s/m 5,8 l/s/m 7,1 l/s/m 21,1 l/s/m

Q at 20 Pa 5,0 l/s/m 8,4 l/s/m 10,4 l/s/m 29,6 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 47 (0;-3) dB 44 (-1;-4) dB 41 (-1;-3) dB 33 (-1;-2) dB

- in closed position 51 (-1;-3) dB n.p.d. n.p.d. n.p.d.

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,3 W/m²K 2,3 W/m²K 2,3 W/m²K 2,1 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Height 80 mm (box height) / 126 mm (total height with flanges)

Max. length 2000 mm (1250 mm for cord control)

86

3

2020 40

25 - 57

Endcap size = 32,5 mm Endcap size = 32,5 mm

Page 42: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

42

AK80GL < Acoustic flap ventilators glazed-in/at transom

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

Compact non self-regulating acoustic window vent for glazed-in installation

The AK80GL is a thermally broken acoustic vent with a pleasing compact design. Four different types are developed, each with their specific air-flow and sound absorption. The AK80GL is available for installation on glass or at transom (using the additional transom profiles).

Glazed-in installation or at transomThe AK80 is available for glazed-in installation, and can also be placed at transom. This vent is applicable for aluminium, timber and PVC window frame types.

Thermally brokenNo cold air transfer from outside to inside.

Coanda effectThe interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Sound absorbingVarious sound reduction levels (depending on the type), from 33 (-1;-2) dB up to 47 (0;-3) dB in open position.

Insect mesh

CO

AN D A - E F F E

CT

Page 43: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

43

Acoustic flap ventilators glazed-in/at transom > AK80GL

Section detail

Technical characteristics AK80GL/1 AK80GL/2 AK80GL/3 AK80GL/4

Airflow

Equivalent area 1488 mm²/m 2163 mm²/m 2545 mm²/m 8780 mm²/m

Q at 1 Pa 1,2 l/s/m 1,7 l/s/m 2,0 l/s/m 6,9 l/s/m

Q at 1 Pa 4,2 m³/h/m 6,1 m³/h/m 7,2 m³/h/m 24,8 m³/h/m

Q at 2 Pa 1,6 l/s/m 2,5 l/s/m 2,9 l/s/m 9,7 l/s/m

Q at 10 Pa 3,6 l/s/m 5,8 l/s/m 7,1 l/s/m 21,1 l/s/m

Q at 20 Pa 5,0 l/s/m 8,4 l/s/m 10,4 l/s/m 29,6 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 47 (0;-3) dB 44 (-1;-4) dB 41 (-1;-3) dB 33 (-1;-2) dB

- in closed position 51 (-1;-3) dB n.b. n.b. n.b.

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 2,3 W/m²K 2,1 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 108 mm

Height 80 mm (box height) / 123 mm (total height with flanges)

Glass thickness 20, 24, 28, 32 or 36 mm

Max. length 2000 mm (1250 mm for cord control)

20/24/28/32/36

25

108

123

40

26/30/34/38/4296

18,595

111

Endcap size = 57,5 mm

Page 44: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

44

Self-regulating flap ventilator with a superior sound ab-sorption

RENSON has developed the Sonovent range to meet with two aspects of living comfort:- physical comfort: fresh and healthy air without draughts- acoustic comfort: up to 56 dB sound reduction

The Sonovent is an extensive range of self-regulating window vents with a superior air sound insulation. Four types of the Sonovent are available; Small, Medium, Large and Xlarge, each model having 4 four different air slot possibilities (10, 15, 20 or 25 mm). This comes up to 16 alterna-tives in total, each model with a different airflow and sound reduction. Furthermore, thermal breaks can be positioned differently, depending on the model and installation method. The Sonovent range therefore offers an ideal solution for every situation.

Glazed-in or at transomThe Sonovent is preferably placed at transom. By adding L-profiles to the upper and lower side, the Sonovent can also be placed on glass.

Thermally brokenNo cold air-transfer from outside to inside. Thermal breaks can be posi-tioned differently depending on the model and installation method.

Self-regulatingThanks to its self-regulating flap, the Sonovent ensures the supply of fresh and healthy air without draughts.

Sound absorptionVarious sound reduction levels (depending on the type), from 37dB up to 56 dB.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

A

T T R A N S O

M

Sonovent® < Acoustic flap ventilators glazed-in/at transom

Page 45: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

45

Acoustic flap ventilators glazed-in/at transom > Sonovent®

The versatile Sonovent® - range

4 different models with different positions of the thermal break

Models: Small – Medium – Large – Xlarge Thermal break: different positions 1 to 6

SMALL MEDIUM LARGE XLARGE

80

285280

325

160

205 200

245 240

120

1

2

3

4

5

6

Installation & model Possible positions of the thermal break

Glazed-in

Small 2 - 3

Medium 2 - 3

Large 2 - 3 - 4

At transom

Small 1 – 2 - 3

Medium 2 - 3 - 4

Large 2 - 3 - 4

Xlarge 2 - 3 – 4 - 5

Doorlaat 25 mm Doorlaat 10 mmDoorlaat 15 mmDoorlaat 20 mm

Airslot opening 10 mm

1 0

Airslot opening: 10 - 15 - 20 -25 mm

Airslot opening 15 mm

1 5

Doorlaat 25 mm Doorlaat 10 mmDoorlaat 15 mmDoorlaat 20 mm

Airslot opening 20 mm

20

Doorlaat 25 mm Doorlaat 10 mmDoorlaat 15 mmDoorlaat 20 mm

Airslot opening 25 mm

25

Doorlaat 25 mm Doorlaat 10 mmDoorlaat 15 mmDoorlaat 20 mm

Page 46: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

46

Sonovent® < Acoustic flap ventilators glazed-in/at transom

Installation

The Sonovent is designed to be installed glazed-in or at transom (pre-ferred installation). Hidden installation behind louvers or in a ventilated panel of a curtain wall system is also possible and commonly applied in offices, schools, … . By choosing the right model of Sonovent and varying the length, the required airflow together with the necessary acoustic performances can be reached.

Glazed-in Fully glazed-in (at transom) (recommended installation)

Hidden installation (behind louvres)

Section detail

205/245/285/325

170/210/250/290

105

20/25

20

10/15/20/25

20/24/28/32

26/30/34/38

Endcap size = 3 mm

Page 47: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

47

Acoustic flap ventilators glazed-in/at transom > Sonovent®

Technical characteristics Sonovent®

Small Medium Large Xlarge

Airflow

Equivalent area

Air slot 10 mm 17756 mm²/m 17509 mm²/m 16153 mm²/m 14427 mm²/m

Air slot 15 mm 29593 mm²/m 26511 mm²/m 25524 mm²/m 21578 mm²/m

Air slot 20 mm 31813 mm²/m 33292 mm²/m 32059 mm²/m 31073 mm²/m

Air slot 25 mm 33786 mm²/m 34032 mm²/m 33416 mm²/m 32676 mm²/m

Q at 1 Pa

Air slot 10 mm 14,0 l/s/m 13,8 l/s/m 12,7 l/s/m 11,3 l/s/m

Air slot 15 mm 23,3 l/s/m 20,8 l/s/m 20,1 l/s/m 17,0 l/s/m

Air slot 20 mm 25,0 l/s/m 26,2 l/s/m 25,2 l/s/m 24,4 l/s/m

Air slot 25 mm 26,6 l/s/m 26,7 l/s/m 26,3 l/s/m 25,7 l/s/m

Q at 1 Pa

Air slot 10 mm 50,2 m³/h/m 49,5 m³/h/m 45,7 m³/h/m 40,8 m³/h/m

Air slot 15 mm 83,7 m³/h/m 75,0 m³/h/m 72,2 m³/h/m 61,0 m³/h/m

Air slot 20 mm 90,0 m³/h/m 94,2 m³/h/m 90,7 m³/h/m 87,9 m³/h/m

Air slot 25 mm 95,6 m³/h/m 96,3 m³/h/m 94,5 m³/h/m 92,4 m³/h/m

Q at 2 Pa

Air slot 10 mm 14,0 l/s/m 13,8 l/s/m 12,7 l/s/m 11,3 l/s/m

Air slot 15 mm 23,3 l/s/m 20,8 l/s/m 20,1 l/s/m 17,0 l/s/m

Air slot 20 mm 25,0 l/s/m 26,2 l/s/m 25,2 l/s/m 24,4 l/s/m

Air slot 25 mm 26,6 l/s/m 26,7 l/s/m 26,3 l/s/m 25,7 l/s/m

Q at 10 Pa

Air slot 10 mm 15,3 l/s/m 15,1 l/s/m 14,0 l/s/m 12,5 l/s/m

Air slot 15 mm 25,6 l/s/m 22,9 l/s/m 22,1 l/s/m 18,7 l/s/m

Air slot 20 mm 27,5 l/s/m 28,8 l/s/m 27,7 l/s/m 26,9 l/s/m

Air slot 25 mm 29,2 l/s/m 29,4 l/s/m 28,9 l/s/m 28,2 l/s/m

Q at 20 Pa

Air slot 10 mm 22,9 l/s/m n.p.d. n.p.d. n.p.d.

Air slot 15 mm 28,5 l/s/m n.p.d. n.p.d. n.p.d.

Air slot 20 mm 29,2 l/s/m n.p.d. n.p.d. n.p.d.

Air slot 25 mm 27,1 l/s/m 27,5 l/s/m 25,0 l/s/m n.p.d.

Comfort

Sound reduction Dn,e,w (C;C

tr) in open position

Air slot 10 mm 46 (-1;-5) dB 48 (-2;-6) dB 50 (-2;-6) dB 56 (-2;-6) dB

Air slot 15 mm 41 (-1;-2) dB 45 (-2;-6) dB 49 (-2;-7) dB 53 (-2;-6) dB

Air slot 20 mm 40 (-1;-3) dB 43 (0;-3) dB 44 (-2;-6) dB 46 (-2;-6) dB

Air slot 25 mm 37 (-1;-3) dB 39 (-1;-4) dB 41 (-2;-6) dB 45 (-2;-6) dB

Sound reduction Dn,e,w (C;C

tr) in closed position

n.p.d.

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, cord, rod, motor

U value 4,5 W/m²K 4,6 W/m²K 4,6 W/m²K 4,7 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 130 mm (flange 20 mm), 135 mm (flange 25 mm)

Height 105 mm (total height with flanges: 145 or 150 mm)

Glass thickness 20, 24, 28, 32 (or more upon request)

Max. length 2000 mm (glazed-in installation) / 2500 mm (installation at transom)

Depth/Total depth 170/205 mm (Small), 210/245 mm (Medium), 250/285 mm (Large) or 290/325 mm (Xlarge)

Page 48: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

48

Sonovent® Compact < Acoustic flap ventilators glazed-in/at transom

Compact self-regulating acoustic flap ventilator

The Sonovent Compact is a self-regulating and acoustic window vent for glazed-in installation (or at transom using an additional transom profile). This compact sound absorbing window vent offers an excellent compro-mise between acoustic performance and airflow. The Sonovent Compact has 3 different air slot possibilities (10, 13 or 15 mm), so three different airflows can be obtained within a single model.

Glazed-in installation (or at transom)The Sonovent Compact can be installed glazed-in or at transom (using the additional transom profiles).

Thermally brokenNo cold air transfer from outside to inside.

Self-regulatingThanks to its self-regulating flap, the Sonovent Compact ensures the supply of fresh and healthy air without draughts.

Three different airflow levels in one modelThe Sonovent Compact has 3 different air slot possibilities (10, 13 or 15 mm), so three different airflows can be obtained within a single model.

Sound absorptionVarious sound reduction levels (depending on the type), from 33 dB up to 36 dB.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

A

T T R A N S O

M

Page 49: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

49

Acoustic flap ventilators glazed-in/at transom > Sonovent® Compact

Section detail

20/24/28/32/36

26/30/34/38/42

27,7 43

145

60

10/1

3/1

5

Technical characteristics Sonovent® Compact

Airflow

Equivalent area

Air slot 10 mm 15334 mm²/m

Air slot 13 mm 19278 mm²/m

Air slot 15 mm 24687 mm²/m

Q at 1 Pa

Air slot 10 mm 12,1 l/s/m

Air slot 13 mm 15,2 l/s/m

Air slot 15 mm 19,4 l/s/m

Q at 1 Pa

Air slot 10 mm 43,4 m³/h/m

Air slot 13 mm 54,5 m³/h/m

Air slot 15 mm 69,8 m³/h/m

Q at 2 Pa

Air slot 10 mm 16,4 l/s/m

Air slot 13 mm 18,8 l/s/m

Air slot 15 mm 19,9 l/s/m

Q at 10 Pa

Air slot 10 mm 17,3 l/s/m

Air slot 13 mm 18,8 l/s/m

Air slot 15 mm 18,6 l/s/m

Q at 20 Pa

Air slot 10 mm 17,8 l/s/m

Air slot 13 mm 18,7 l/s/m

Air slot 15 mm 19,1 l/s/m

Comfort

Sound reduction Dn,e,w

(C;Ctr) in open position

Air slot 10 mm 36 (0;-1) dB

Air slot 13 mm 35 (0;-1) dB

Air slot 15 mm 33 (0;-1) dB

Sound reduction Dn,e,w

(C;Ctr) in closed position

n.p.d.

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, cord, rod, motor

U value 6,0 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Glass reduction 78 mm

Height 75 mm (box height) /

95 mm (total height with flanges)

Glass thickness 20, 24, 28, 32 or 36 mmMax. length

2000 mm (glazed-in) or 2500 mm (at transom)

Endcap size = 3 mm

Page 50: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

50

Sonovent® I < Acoustic flap ventilators glazed-in/at transom

Flap ventilator with a superior sound absorption and increased airflow

The Sonovent I is a Sonovent with an increased airflow specifically de-signed for offices, commercial buildings and shops. Unlike the Sonovent, the Sonovent I is not self-regulating and the airslot opening is 36 mm resulting in an increased airflow.

Installation at transom (or glazed-in)The Sonovent I is preferably placed at transom. By adding L-profiles to the upper and lower side, the Sonovent I can also be placed on glass.

Thermally brokenNo cold air transfer from outside to inside. Thermal breaks can be posi-tioned differently depending on the model and installation method.

Sound absorptionVarious sound reduction levels (depending on the type), from 32 dB up to 36 dB.

Very high airflowUp to 175,3 m³/h/m (Q at 2 Pa).

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

Page 51: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

51

Acoustic flap ventilators glazed-in/at transom > Sonovent® I

Section detail

205/245/285/325

170/210/250/290

105

20/25

36

20

Technical characteristics Sonovent® I

Small Medium Large Xlarge

Airflow

Equivalent area 43520 mm²/m 44029 mm²/m 43392 mm²/m 43138 mm²/m

Q at 1 Pa 34,2 l/s/m 34,6 l/s/m 34,1 l/s/m 33,9 l/s/m

Q at 1 Pa 123,1 m³/h/m 124,6 m³/h/m 122,8 m³/h/m 122,0 m³/h/m

Q at 2 Pa 48,2 l/s/m 48,7 l/s/m 48,0 l/s/m 48,0 l/s/m

Q at 10 Pa 107,8 l/s/m 107,1 l/s/m 107,3 l/s/m 107,3 l/s/m

Q at 20 Pa 152,4 l/s/m 150,5 l/s/m 151,8 l/s/m 151,8 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 32 (-1;-3) dB 33 (-1;-3) dB 35 (-1;-4) dB 36 (-1;-4) dB

- in closed position 44 (-1;-4) dB 48 (-1;-5) dB 49 (-2;-5) dB 49 (-1;-5) dB

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Motor

U value 5,2 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 130 mm (flange 20 mm), 135 mm (flange 25 mm)

Height 105 mm (box height) / 145 mm or 150 mm (total height with flanges)

Glass thickness 20, 24, 28 or 32 (or more upon request)

Depth 170 mm 210 mm 250 mm 290 mm

Max. length 2000 mm (glazed-in) / 2500 mm (at transom)

Endcap size = 3 mm

Page 52: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

52

Sonovent® V < Acoustic flap ventilators glazed-in/at transom

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

Mechanical ventilator with a superior sound absorption

Sonovent V is a mechanical ventilator with a compact radial fan which can produce up to 220 m³/h/m designed for non-residential applica-tions. The sonovent V can be used to mechanically supply or extract the room air (not suitable as kitchen or bathroom extractor). The ventilator starts to work automatically when fully opening the inner flap. The inner flap can be controlled manually or can be motorized. Thanks to acous-tic insulation within this ventilator, the ventilator will reduce external soundlevels even when the fanmotor is switched on. The mechanical parts and the acoustic insulation are removable from the interior. It is possible to provide group control of up to 4 Sonovents, by wiring the fanmotors in parallel.

Installation at transomThe Sonovent V is designed for installation at transom only (not glazed-in).

Thermally brokenNo cold air transfer from outside to inside.

Sound absorbing35 (-1;-3) dB in open position

Insect mesh

Page 53: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

53

Section detail

Acoustic flap ventilators glazed-in/at transom > Sonovent® V

Supply

Extraction

Position 1

4

1

4

45 12580 136

159

105

155

2525

25

Position 2

4

2

4

85 85120 96

119

105

155

2525

25

Position 3

4

3

4

125 45160 56

79

105

155

2525

25

Position 1

4

1

4

45 12580 136

159

105

155

2525

25

Position 2

4

2

4

85 85120 96

119

105

155

2525

25

Position 3

4

3

4

125 45160 56

79

105

155

2525

25

Technical characteristics Sonovent® V

Airflow

Supply 61,11 l/s/m

Supply 220 m³/h/m

Extraction 61,11 l/s/m

Extraction 220 m³/h/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 35 (-1;-3) dB

- in closed position n.p.d.

Technical characteristics

Controllable internal flap continuous

Control options internal flap Manual, cord, rod, motor

U value 4,5 W/m²K

Air leakage at 50 Pa n.p.d.

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to n.p.d.

Fanmotor:

- Powersupply 24 VDC

- Group control up to 4 motors

Dimensions

Height 105 mm (total height with flange profiles: 155 mm)

Glass thickness 20, 24, 28, 32 mm (other thicknesses available upon demand)

Max. length 2500 mm

Depth / Total depth 170 / 205 mm

Endcap size = 3 mm

Page 54: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

54

Oxyvent® < Flap ventilator for conservatories

Natural extraction for conservatories

The Oxyvent is placed in the highest and warmest point of the conser-vatory’s roof. This favours the extraction of hot and humid air using natural convection. Ventilators placed in the lower part of the conserva-tory assure a natural supply of fresh air. This patented natural extrac-tion system has been designed to prevent water infiltration (in normal conditions).

Control the temperature in a natural wayThanks to natural convection, cool and fresh air is supplied through vents in the vertical glass wall, while warm and humid air is extracted through the Oxyvent.

Glazed-in installation or on sandwich panelsThe Oxyvent suits for glazed-in installation and installation in structures with sandwich panels (with thicknesses of 28 up to 86 mm, by steps of 2 mm).

SlopeThe Oxyvent can be mounted on any conservatory roof with a minimum gradient of 5° or on vertical walls.

Thermally brokenNo cold air transfer from outside to inside.

Burglar proofWith the Oxyvent one no longer needs to open up windows in order to ventilate the conservatory, which avoids the risk of burglary.

Insect mesh

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

Page 55: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

55

Flap ventilator for conservatories > Oxyvent®

Section detail

Technical characteristics Oxyvent®

Airflow

Equivalent area 15058 mm²/m

Q at 1 Pa 11,8 l/s/m

Q at 1 Pa 42,6m³/h/m

Q at 2 Pa 16,7 l/s/m

Q at 10 Pa 37,42 l/s/m

Q at 20 Pa 52,9 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 27 (-1;-2) dB

- in closed position 40 (0;-2) dB

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, rod, motor

U value Up to 2,8 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 50 Pa

Dimensions

Glass reduction 210 mm

Height exterior cap 50 mm

Glass thickness 28, 32, 36 mm

Thickness glass / sandwich panel 28 - 86 mm (by steps of 2 mm)

Max. length 1500 mm

Slope Min. gradient of 5° or on vertical walls

210

28 -

38

28 -

38

49.6

15.1

50

210

76 -

86

49.6

15.1

5076

- 8

6

210

52 -

62

49.6

15.1

5052

- 62

210

40 -

50

40 -

50

49.6

15.1

50

210

64 -

74

49.6

15.1

5064

- 7

4

Endcap size = 55 mm

Page 56: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

56

Sonovent® D < Acoustic ventilator for slant roofs

Self-regulating, acoustic ventilator for installation in rooms below slant roofs

The Sonovent D makes it possible to ventilate rooms below slant roofs, even if no windows are present. Moreover, thanks to its self-regulating flap, the Sonovent D ensures the supply of fresh and healthy air without draughts.

Installation in slant roofsThe Sonovent D has been developed for installation in slant roofs with a minimal slope of 22,5° in order to avoid water infiltration. Importantly, the entire length of the Sonovent D has to be covered with ventilation tiles.

Thermally brokenNo cold air transfer from outside to inside.

Self-regulating Thanks to its self-regulating flap, the Sonovent D ensures the supply of fresh and healthy air without draughts.

Sound absorptionVarious sound reduction levels (depending on the type), up to 41 (-2;-6) dB.

Insect mesh

IN T

H

E R O O F

T

HE

R

MA L L Y B R O

KE

N

SE

LF-REGULATING

Page 57: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

57

Acoustic ventilator for slant roofs > Sonovent® D

Section detail

Technical characteristics Sonovent® D

Small Medium Large

Airflow

Equivalent area 31070 mm2/m

Q at 1 Pa 24,4 l/s/m

Q at 1 Pa 87,9 m3/h/m

Q at 2 Pa 28,0 l/s/m

Q at 10 Pa 30,8 l/s/m

Q at 20 Pa 34,8 l/s/m

Comfort

Sound reduction Dn,e,w

(C;Ctr)

- in open position 37 (-1;-3) dB 39 (-1;-4) dB 41 (-2;-6) dB

- in closed position n.p.d.

Technical characteristics

Controllable internal flap continuous adjustment

Control options internal flap Manual, cord, rod, motor

U value 4,5 W/m²K 4,6 W/m²K 4,6 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 100 Pa

Dimensions

Height 105 mm (box height) / 155 mm (total height with flanges)

Roof thickness 170 mm 210 mm 250 mm

Minimal slope 22,5°

Roof opening 115 mm

Max. length 1000 mm

112-

115

spac

e

min. 22,5°

Endcap size = 3 mm

Page 58: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

58

Transivent® < Roller shutter flap ventilator

Self-regulating ventilator for installation in roller shutters

The Transivent is a self-regulating, thermally broken ventilator with an attractive design, for mounting in a traditional roller shutter housing. The curved aluminium inner profile deflects the incoming air upwards into the room.

The ideal solution for renovationThe Transivent, which can be easily integrated in roller shutters, has been developed for situations in which initially no ventilation solution has been foreseen, though in which ventilation is needed.

Thermally brokenNo cold air transfer from outside to inside.

i-Flux®Thanks to its self-regulating flap, the Transivent ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an optimal spread of fresh air in the room.

Insect mesh

T

HE

R

MA L L Y B R O

KE

N

Page 59: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

59

Roller shutter flap ventilator > Transivent®

Section detail

Technical characteristics Transivent®

Airflow

Equivalent area 13748 mm²/m

Q at 1 Pa 10,8 l/s/m

Q at 1 Pa 38,9 m³/h/m

Q at 2 Pa 15,2 l/s/m

Q at 10 Pa 20,1 l/s/m

Q at 20 Pa 19,9 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 28 (-1;-2) dB

- in closed position 44 (-1;-2) dB

Technical characteristics

Controllable internal flap 5 stepped positions

Control options internal flap Manual, cord, rod, motor

U value 3,0 W/m²K

Air leakage at 50 Pa <15% (in closed position)

Watertightness in closed position, up to 650 Pa

Watertightness in open position, up to 150 Pa

Dimensions

Installation height 91 mm

Fitted height 48 mm

Slot height 50 mm

Depth 60 mm

Max. length 2200 mm (1500 mm for cord control)

48 m

m PVC

ALU

26 mm L PVC = L1 - 68 mm 26 mm

L ALU = L1 - 4 mm

L1

2 mm 2 mm

Page 60: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

60

THL100 – THL100V < Sliding vents

THL100: Horizontal sliding ventTHL100V: Vertical sliding vent

The THL100 is a thermally broken louvred ventilator, made to measure, installed in a vertical (THL100V) or horizontal (THL100) position.The THL100V creates a natural air circulation: incoming fresh air at the bottom and outgoing humid warm air at the top of the ventilator.

Glazed-in installation or installation at transomTHL100 or THL100V for glazed-in installation (glass thickness 15, 20, 24, 28 mm)THL100-TR or THL100V-TR for installation at transom (glass thickness 20, 24, 28 mm)Not suitable for installation in coastal environments or near the beach.

Thermally brokenNo cold air transfer from outside to inside.

Louvres at the outside, a slider at the inside

Insect mesh

Easy and efficient

G

L A Z E D - I N

T

HE

R

MA L L Y B R O

KE

N

A

T T R A N S O

M

Page 61: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

61

Sliding vents > THL100 – THL100V

Section detail

THL100

THL100 V

100

1151311

20

20

100

129

1311

20

26

20

20

13

100

115

144

44

13

100 12

9

11

30

Technical characteristics THL100 THL100V

Airflow

Equivalent area 16759 mm²/m 12770 mm²/m

Q at 1 Pa 13,2 l/s/m 10,0 l/s/m

Q at 1 Pa 47,4 m³/h/m 36,1 m³/h/m

Q at 2 Pa 18,7 l/s/m 14,2 l/s/m

Q at 10 Pa 41,6 l/s/m 32,1 l/s/m

Q at 20 Pa 58,9 l/s/m 45,5 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 22 (0;-1) dB

- in closed position 42 (-1;-2) dB

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, cord, rod, chain, motor

U value 3,9 W/m²K

Air leakage at 50 Pa n.p.d.

Watertightness in closed position, up to 400 Pa

Watertightness in open position, up to n.p.d.

Dimensions

Glass reduction 129 mm

Height 144 mm

Glass thickness 15*, 20, 24 or 28 mm

Max. length 3500 mm

* not for installation at transom

Endcap size = 22 mm

Endcap size = 22 mm

Page 62: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

62

T67 – T100 – T130 – T150 < Sliding vents

T67 – T100 – T130 – T150 Horizontal sliding vents in two parts for installation at transom

The T67, T100, T130 en T150 are aluminium sliding vents without thermal break, to be installed at transom. These types are composed of two unattached parts; the outer part is a decorative louvre with inclined blades to ensure rain protection, the inside part is an aluminium slider that can be adjusted to control the airflow.Not suitable for installation in coastal environments or near the beach.

Installation at transomThe T67, T100, T130 en T150 can be installed at transom.

Insect mesh

A

T T R A N S O

M

Page 63: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

63

Sliding vents > T67 – T100 – T130 – T150

Section detail

T67

T100

T130

T150

20 9.5

67.5

20 9.510

020 9.5

130

20 9.5

150

D67 A67 67-1 A67-1

D100 A100 D101 A101

D130 A130 D131 A131

D150 A150 D151 A151

Technical characteristics T67 T100 T130 T150

Airflow

Equivalent area 11224 mm²/m 17326 mm²/m 24589 mm²/m 27992 mm²/m

Q at 1 Pa 8,8 l/s/m 13,6 l/s/m 19,3 l/s/m 22,0 l/s/m

Q at 1 Pa 31,8 m³/h/m 49,0 m³/h/m 69,6 m³/h/m 79,2 m³/h/m

Q at 2 Pa 12,7 l/s/m 19,5 l/s/m 27,7 l/s/m 31,9 l/s/m

Q at 10 Pa 28,5 l/s/m 43,8 l/s/m 62,1 l/s/m 71,5 l/s/m

Q at 20 Pa 40,2 l/s/m 61,9 l/s/m 87,9 l/s/m 101,0 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position n.p.d.

- in closed position n.p.d.

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, chain, cord Manual, chain, cord, rod, motor

U value n.p.d.

Air leakage at 50 Pa n.p.d.

Watertightness in closed position, up to n.p.d.

Watertightness in open position, up to n.p.d.

Dimensions

Height 67 mm 100 mm 130 mm 150 mm

Max. length 3500 mm

Endcap size = 1,5 mm

Page 64: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

64

Sliding vents without thermal break for glazed-in installation or at transom

The TL67 en TL100(PB) are aluminium sliding vents without thermal break, typically for glazed-in installation. The outer part is a decorative louvre with inclined blades to ensure rain protection, the inside part is an aluminium slider which can be adjusted to control the airflow.The THL100PB is a special version of the TL100 for installation at the bottom of the window.Not suitable for installation in coastal environments or near the beach.

Glazed-in installationThe TL67 en TL100(PB) can be installed glazed-in (at the top of the gla-zing or at the bottom of the glazing: TL100PB), or at transom (using the additional transom profiles).

Insect mesh

TL67 – TL100 – TL100 PB < Sliding vents

A

T T R A N S O

M

G

L A Z E D - I N

Page 65: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

65

Sliding vents > TL67 – TL100 – TL100 PB

Section detail

Technical characteristics TL67 TL100 TL100PB

Airflow

Equivalent area 10137 mm²/m 14198 mm²/m 14198 mm²/m

Q at 1 Pa 8,0 l/s/m 11,2 l/s/m 11,2 l/s/m

Q at 1 Pa 28,7 m³/h/m 40,2 m³/h/m 40,2 m³/h/m

Q at 2 Pa 11,4 l/s/m 16,0 l/s/m 16,0 l/s/m

Q at 10 Pa 25,3 l/s/m 35,8 l/s/m 35,8 l/s/m

Q at 20 Pa 36,2 l/s/m 50,6 l/s/m 50,6 l/s/m

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position n.p.d.

- in closed position n.p.d.

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual, chain, cord Manual, chain, cord, rod, motor

U value n.p.d.

Air leakage at 50 Pa n.p.d.

Watertightness in closed position, up to n.p.d.

Watertightness in open position, up to n.p.d.

Dimensions

Height 67 mm 100 mm 100 mm

Glass reduction 98 mm 129 mm 129 mm

Glass thickness 20 mm 4, 20, 24 mm 20 mm

Max. length 3500 mm

Endcap size = 22 mm

TL-67 TL-100 TL-100 TL-100 TL-100PB

20

26

67.5

111

4

13

100

144

20

26

100

144

24

30

100

144

26

20

100

144

Page 66: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

66

Introduction < Slotvents

RENSON® developed an extensive range of slotvents. The RENSON® slotvents are manufactured in aluminium, this to ensure the highest possible quality and durability. These aluminium slotvents can be powdercoated in any color making a perfect integration possible on wooden, uPVC and aluminium window frames. RENSON® proposes some standard lengths for the slotvents but most of the types can be made to measure.

Slotsize openingsSlotvents are installed on window frames where a slot (10, 12, 16 or 25 mm) is routed through the frame. For long slotvents, en-forcement bridges must be taken into account between the gaps, in order to prevent weakening the window frame. When combining an exterior and an interior slotvent, use the smallest slotsize opening indicated (airflow might be affected).

Permanent slot ventilators for domestic fuel burning appliancesTo comply with Building Regulations and British Standards specific permanent air vents are required to provide combustion air/re-lief air. This non-controllable airvent must allow air passage at all times. The ventilator must be fitted with apertures which prevent the entry of a 10 mm diameter ball, but allow the entry of a 5 mm diameter ball.

The canopy 587P is fitted with a flyscreen to suit the 5/10 mm diameter ball specification.A proposed slotvent set, complying with BS5440 and having approval of British Gas Technology is:exterior: 587P + interior: 587P (inverted, allowing the incoming air to be deflected upwards to avoid undue draughts).

Slotvents are not suitable for use in high rise applications.

250

16

250x16

215

16

21520

(215x16) + 20 + (215x16)

Page 67: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

67

470 Sound absorbing boxD

n,e,w (C;C

tr): 39 (-1;-1) dB

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

470/30 400 45(165 x 25) + 20

+ (165 x 25)1,4 2,0 7,3 1727

470/45 700 45(315 x 25) + 20

+ (315 x 25)2,2 3,2 11,6 2831

478 Flat grill

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

478/1 275 20 230 x 16 1,9 2,8 9,9 2453

478/2 375 20 330 x 16 2,8 3,9 14,2 3512

478/3 475 20(205 x 16) + 20

+ (205 x 16)3,7 5,4 19,3 4753

478/4 700 20(315 x 16) + 25

+ (315 x 16)5,6 8,0 28,8 7119

485 Hit and miss vent

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

485/1 275 22 230 x 16 1,2 1,8 6,4 1551

485/2 375 22 330 x 16 1,9 2,7 9,9 2438

485/3 475 22(210 x 16) + 20

+ (200 x 16)2,5 3,6 13,1 3214

485/4 700 22(310 x 16) + 20

+ (325 x 16)4,1 6,0 21,6 5203

487 tipvent

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

487/1 275 23 250 x 16 3,3 4,7 17,0 4229

487/2 375 23(165 x 16) + 20

+ (165 x 16)4,8 6,8 24,4 6080

487/3 475 23(215 x 16) + 20

+ (215 x 16)5,9 8,3 30,0 7496

487/4 700 23(325 x 16) + 25

+ (325 x 16)9,8 14,0 50,5 12527

Slotvents > Interior slotvents

4540

50

1,25

20

6

2214

5,5

23

ø7

25

Page 68: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

68

488 Patio grille

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

488/1 275 30 250 x 25 3,1 4,3 15,5 3899

488/2 375 30(165 x 25) + 20

+ (165 x 25)4,3 5,9 21,4 5423

488/3 475 30(215 x 25) + 20

+ (215 x 25)4,5 6,8 24,6 5787

488/4 700 30(325 x 25) + 25

+ (325 x 25)8,5 12,1 43,5 10839

489 Bar grille

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

489/1 275 24 237 x 18 1,7 2,5 8,9 2202

489/2 375 24 337 x 18 2,2 3,2 11,7 2822

489/3 475 24(210 x 18) + 17

+ (210 x 18)3,0 4,3 15,3 3807

489/4 700 24(320 x 18) + 22

+ (320 x 18)5,1 7,2 25,8 6477

787AK Tipvent

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

787AK/1 275 28 245 x 16 3,2 4,6 16,7 4127

787AK/2 375 28 345 x 16 4,0 5,7 20,5 5108

787AK/3 475 28(215 x 16) + 20

+ (215 x 16)5,1 7,3 26,3 6525

787AK/4 700 28(325 x 16) + 25

+ (325 x 16)9,0 12,9 46,5 11455

788P Tipvent

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

788P/1 275 28 245 x 16 3,2 4,6 16,7 4127

788P/2 375 28 345 x 16 4,0 5,7 20,5 5108

788P/3 475 28(215 x 16) + 20

+ (215 x 16)5,1 7,3 26,3 6525

788P/4 700 28(325 x 16) + 25

+ (325 x 16)9,0 12,9 46,5 11455

Interior slotvents < Slotvents

1,25

30

7

17,5

8,3

24

15

34

14

34

Page 69: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

69

586 Canopy

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

586/1 275 28 250 x 25 3,3 4,8 17,2 4249

586/2 375 28 350 x 25 4,3 6,2 22,4 5520

586/3 475 28(215 x 25) + 20

+ (215 x 25)6,4 9,0 32,5 8161

586/4 700 28(325 x 25) + 25

+ (325 x 25)8,9 12,8 46,2 11335

471 Self regulating canopy

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

471/1 275 35 250 x 25 1,4 2,0 7,3 1785

471/2 375 35 350 x 25 2,0 3,0 10,8 2527

471/3 475 35(215 x 25) + 20

+ (215 x 25)2,3 3,7 13,2 2951

471/4 700 35(325 x 25) + 25

+ (325 x 25)4,0 6,0 21,5 5055

486 Canopy

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

486/1 275 35 250 x 25 1,7 2,4 8,5 2105

486/2 375 35 350 x 25 2,2 3,2 11,4 2805

486/3 475 35(215 x 25) + 20

+ (215 x 25)3,2 4,6 16,5 4125

486/4 700 35(325 x 25) + 25

+ (325 x 25)4,4 6,2 22,5 5550

Slotvents > Exterior slotvents

20

35

20

35

27

28

Page 70: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

70

587P Canopy

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

587P/1 275 28 250 x 25 3,4 4,8 17,4 4312

587P/2 375 28 350 x 25 4,9 6,9 24,8 6210

587P/3 475 28(215 x 25) + 20

+ (215 x 25)6,6 9,2 33,2 8354

587P/4 700 28(325 x 25) + 25

+ (325 x 25)9,4 13,3 48,0 12015

771AKAcoustic canopyD

n,e,w (C;C

tr): 36 (-1;-1) dB

Type Length(mm)

Height(mm)

Slotsize opening

(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

771AK/2 415 52(165 x 25) + 20

+ (165 x 25)2,7 4,0 14,1 3372

771AK/3 565 52(240 x 25) + 20

+ (240 x 25)4,8 6,9 24,8 6044

771AK/5* 565 52(240 x 25) + 20

+ (240 x 25)4,9 7,0 25,2 6294

* without self-regulating flap

590 Clip in canopy

Type Length(mm)

Height(mm)

Slotsize opening(mm)

Airflow

1 Pa(l/s)

2 Pa(l/s)

2 Pa(m3/h)

EquivalentArea (mm2)

590/6 290 28 284 x 16 3,5 5,0 18,1 4498

590/7 470 28(222 x 16) + 20

+ (222 x 16)6,1 8,7 31,2 7800

590/8 565 28(270 x 16) + 19

+ (270 x 16)7,1 10,1 36,4 9067

Exterior slotvents < Slotvents

27

28

52

52

27

28

Page 71: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

71

Slotvents > Combinations

Sonoslot®Self-regulating acoustic slotvent kit

The Sonoslot is a self-regulating, sound absorbing slotvent kit consis-ting of an external slotvent, internal slotvent and a plastic sleeve with integrated sound absorbing baffle in-between. The Sonoslot is available in 4 sizes: 275 mm, 375 mm, 475 mm and 700 mm.The aluminium external slotvent is self-regulating. This keeps the air-flow fairly uniform in strong winds and prevents draughts. The external slotvent is perforated and also acts as an insect mesh screen. The noise-damping baffle, made of sound absorbing foam, is standard 70 mm thick and the plastic sleeve is standard 90 mm thick, but both can be easily adapted to suit different window frame depths. The small, narrow and discrete aluminium internal slotvent can be completely closed. When open, it deflects the airflow upwards to prevent direct draughts.The Sonoslot is also available with permanently open clips. i-Flux®Thanks to the self-regulating flap in its exterior slotvent, the Sonoslot ensures the supply of fresh and healthy air without draughts. Moreover, the interior profile deflects the incoming air upwards, causing an opti-mal spread of fresh air in the room.

Sound absorbingSonoslot: up to 38 (0;0) dB in open position

Insect mesh

Technical characteristics Sonoslot® 275 mm Sonoslot® 375 mm Sonoslot® 475 mm Sonoslot® 700 mm

Airflow

Equivalent area 1273 mm2 1607 mm2 2121 mm2 3181 mm2

Q at 1 Pa 1,0 l/s 1,3 l/s 1,7 l/s 2,5 l/s

Q at 1 Pa 3,6 m³/h 4,5 m³/h 6,0 m³/h 9,0 m³/h

Q at 2 Pa 1,4 l/s 1,7 l/s 2,3 l/s 3,4 l/s

Q at 10 Pa 3,2 l/s 4,0 l/s 5,3 l/s 8,0 l/s

Q at 20 Pa 3,3 l/s 4,2 l/s 5,6 l/s 8,4 l/s

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 38 (0;0) dB 37 (0;0) dB 36 (0;0) dB 34 (0;0) dB

- in closed position n.p.d.

Technical characteristics

Controllable internal flap Continuous adjustment

Control options internal flap Manual

U value 1,4 W/m².K

Air leakage at 50 Pa < 15 % in closed position

Watertightness in closed position, up to n.p.d.

Watertightness in open position, up to n.p.d.

Dimensions

Height 35 mm

Length 275 mm 375 mm 475 mm 700 mm

Slotsize opening (105,5 x 16) + 24 + (105,5 x 16)

(105,5 x 16) + 14,3 + (105,5 x 16) + 14,3 +

(105,5 x 16)

(105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 +

(105,5 x 16)

(105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 +

(105,5 x 16)

Length acoustic foam 2 x 103 mm 3 x 103 mm 4 x 103 mm 6 x 103 mm

Depth acoustic foam 70 mm

Depth plastic sleeve 90 mm

Endcap size (exterior): 17,5 mmEndcap size (interior): 15 mm

Page 72: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

72

Combinations < Slotvents

SE

LF-REGULATING

Sonoslot® MaxSelf-regulating slotvent kit with high acoustic damping

Sonoslot Max is a self-regulating slotvent kit offering a higher sound ab-sorption than the Sonoslot, existing of an external slotvent, an internal slotvent and a plastic sleeve with integrated sound absorbing baffle in-between.The aluminium external slotvent is self-regulating, which keeps the airflow fairly uniform in strong winds and prevents draughts. The exter-nal slotvent is perforated and also acts as an insect mesh screen. The noise-damping baffle is standard 70 mm thick and the plastic sleeve is standard 90 mm thick, but both can easily be adapted to suit different window frame depths.This slotvent combination suits for all window depths. It can be used for both new-built and renovation projects.

Self-regulatingThanks to the self-regulating flap in its exterior slotvent, the Sonoslot Max ensures the supply of fresh and healthy air without draughts.

Sound absorbingUp to 40 (-1;-2) dB in open position.

Insect mesh

Technical characteristics Sonoslot® Max

Without acoustic foam With acoustic foam

Airflow

Equivalent Area 2298 mm2 1555 mm2

Q at 1 Pa 1,8 l/s 1,2 l/s

Q at 1 Pa 6,5 m3/h 4,4 m3/h

Q at 2 Pa 2,7 l/s 1,9 l/s

Q at 10 Pa 6,8 l/s 5,1 l/s

Q at 20 Pa 6,9 l/s 7,6 l/s

Comfort

Sound reduction Dn,e,w (C;C

tr)

- in open position 38 (-1;-2) dB 40 (-1;-2) dB

- in closed position n.p.d.

Technical characteristics

Controllable internal flap no

Control options internal flap n.a.

U value n.p.d.

Air leakage at 50 Pa n.p.d.

Watertightness in closed position, up to n.p.d.

Watertightness in open position, up to n.p.d.

Dimensions

Height 35 mm (exterior part) / 45 mm (interior part)

Length 700 mm

Slotsize opening (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16) + 7,5 + (105,5 x 16)

Length acoustic foam n.a. 6 x 103 mm

Depth acoustic foam n.a. 70 mm

Depth plastic sleeve 90 mm

Endcap size (exterior): 17,5 mmEndcap size (interior): 1,5 mm

Page 73: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

73

Slotvents > Combinations

Slotvent sets

Different slotvent combinations are possible. Hereby some proposed slotvent sets.

586 + 487

Airflow 1 Pa 2 Pa 2 Pa Equivalent

Area

586/1 + 487/1 2,3 l/s 3,4 l/s 12,1 m³/h 2968 mm²

586/2 + 487/2 3,6 l/s 5,1 l/s 18,4 m³/h 4538 mm²

586/3 + 487/3 4,6 l/s 6,6 l/s 23,6 m³/h 5874 mm²

586/4 + 487/4 6,9 l/s 9,8 l/s 35,2 m³/h 8744 mm²

771 AK + 787 AKD

n,e,w (C;C

tr): 40 (-1;-2) dB

Airflow 1 Pa 2 Pa 2 Pa Equivalent

Area

771 AK/2 + 787 AK/2 2,7 l/s 3,9 l/s 13,9 m³/h 3471 mm²

28 m

m

586

23 m

m

487

52 m

m

771 AK

34 m

m

787 AK

Page 74: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

74

Fixvent® Mono AKEVO < Combined ventilation and sun shading overframe

O

V E R F R A M

E

T

HE

R

MA L L Y B R O

KE

N

The perfect combination of ventilation, windproof sun protection and insect resistance

RENSON® offers with the Fixvent Mono AKEVO an aesthetical and com-fortable solution which combines windproof sun protection, insect resistance and ventilation. The product, being installed overframe as a monobloc, offers several advantages:

• High thermal comfort:- solid U-values: up to 0,32 W/m²K (EXTREME- version)

• High visual comfort:- control of incoming light- maximal see-through to the external side even with the screen com-

pletely down• High acoustic comfort:

- different acoustic levels available offering a solution to every situa-tion

• High aesthetical finish:- hidden installation with a maximal respect for the architecture:

can be installed on aluminium, wood, uPVC windows in all possible window depths

- hidden weld seam at the height of the bottom bar- large screen surfaces possible

• High physical comfort:- i-Flux technology: optimal comfort, minimal energy loss

The Fixvent Mono AKEVO allows an easy and smooth overframe installa-tion for window depths between 50 and 215 mm. Thanks to the patented Connect&Go- and Click&Safe-technology, an easy (dis)moun-ting of the screen tube can be guaranteed. the Fixscreen–technology provides a tight and windproof screen up to 130km/h. Then there is the Smooth-technology, which provides the zipper guides of a patented wear-resistant layer and makes the screen go up and down smoothly and silently.

Moreover thanks to the same “look & feel”, The Fixvent Mono AKEVO can perfectly be combined with the Fixscreen Mono AKEVO, which brings wind resistant sun shading and insect resistance together in one product.

The Fixvent range consists of:

Fixvent® Mono AKEVO

• Ideal solution for new-build, (large) renovations and projects• Constant supply of fresh and healthy air: self-regulating as from

2 Pa• 3 levels of sound absorption in open position:

- Fixvent Mono AKEVO: up to 40 (-1;-4) dB- Fixvent Mono AKEVO Ultra: up to 45 (-1;-5) dB- Fixvent Mono AKEVO Extreme: up to 48 (-2;-5) dB

Fixvent® Mono UTEVO

• Especially developed for utility buildings in which both the natural air supply and mechanical extraction are located in the same room

• Ideal solution for rooms with a high occupancy (as class rooms, offices, ...)

• Constant higher level of basic ventilation: self-regulation as from 10 Pa

• 2 levels of sound absorption in open position:- Fixvent Mono UTEVO: up to 40 (-1;-4) dB- Fixvent Mono UTEVO Ultra: up to 45 (-1;-5) dB

• No visual difference with Fixvent Mono AKEVO

For further information: www.renson.eu

Page 75: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

75

Combined ventilation and sun shading overframe > Fixvent® Mono AKEVO

Technical characteristics Small Medium Large X-Large XX-Large

Airflow

Equivalent Area

Fixvent® Mono AKEVO 18324 mm2/m

Fixvent® Mono AKEVO ULTRA 4836 mm2/m

Fixvent® Mono AKEVO EXTREME 2800 mm2/m

Fixvent® Mono UTEVO 19724 mm2/m

Fixvent® Mono UTEVO ULTRA 4836 mm2/m

Q at 1 Pa

Fixvent® Mono AKEVO 12,8 l/s/m

Fixvent® Mono AKEVO ULTRA 3,7 l/s/m

Fixvent® Mono AKEVO EXTREME 2,1 l/s/m

Fixvent® Mono UTEVO 15,5 l/s/m

Fixvent® Mono UTEVO ULTRA 3,7 l/s/m

Comfort

Sound reduction Dnew

(C;Ctr) in open position (screen up)

Fixvent® Mono AKEVO 33(0;-2)dB 35(0;-3)dB 36(-1;-4)dB 37(-1;-4)dB 40(-1;-4) dB

Fixvent® Mono AKEVO ULTRA n.a. 38(0;-2)dB 40(-1;-4)dB 43(-1;-4)dB 45(-1;-5)dB

Fixvent® Mono AKEVO EXTREME n.a. 43(0;-3)dB 43(0;-3)dB 46(-1;-4)dB 48(-2;-5)dB

Fixvent® Mono UTEVO 33(0;-2)dB 35(0;-3)dB 36(-1;-4)dB 37(-1;-4)dB 40(-1;-4) dB

Fixvent® Mono UTEVO ULTRA n.a. 38(0;-2)dB 40(-1;-4)dB 43(-1;-4)dB 45(-1;-5)dB

Technical specifications

Self-regulating at 2Pa yes (UT-version at 10 Pa)

Thermally broken yes

U-value (W/m²K)

Fixvent® Mono AKEVO 1,47 0,98 0,80 0,77 0,72

Fixvent® Mono AKEVO ULTRA n.a. 0,70 0,55 0,46 0,41

Fixvent® Mono AKEVO EXTREME n.a. 0,62 0,47 0,38 0,32

Fixvent® Mono UTEVO 1,47 0,98 0,80 0,77 0,72

Fixvent® Mono UTEVO ULTRA n.a. 0,70 0,55 0,46 0,41

Airflow leakage in closed position < 15% at 50 Pa

Insect mesh yes

Control

Screen motor control, manually (not for Ultra/Extreme)

Ventilation flap manually, rod, motor

Dimensions

Box

Box height (mm) 132

Box width (mm) 167 197 227 257 287

Compatible window depths (mm) 50-94 95-124 125-154 155-184 185-215

Screen: max. WxH (mm)+max. surface

Single (1 screen - 1 control) 4000 x 3000 (12 m² for motor control; 7,5 m² for manual control)

Coupled (2 parts - 2 motors) 6000 x 3000 (18 m²)

Bottom bar (DxH) (mm) 30 x 57

Section detail

Fixvent® Mono AKEVO Small

132

Fini

shed

hei

ght

Win

dow

hei

ght

Page 76: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

76

Glazing gasketsRENSON advises the use of special designed glazing gaskets;Nr 019, colour: black, for glass thickness 36 – 40 – 44 mmNr 029, colour: black, for glass thickness 28 – 36 mmNr 034, colour: grey, for glass thickness 20 – 28 mmNr 039, colour: black, for glass thickness 20 – 28 mmNr 049, colour: black, for glass thickness 20 – 28 mmNr 104, colour: black, for glass thickness 4 mm

Controls- Manual: possible through manually opening/closing of the flap (eg. Invisivent EVO range), knob (e.g. THM90EVO), lever

(e.g. AR75). Standard lever is 30 mm, but longer levers (40, 50, 60 and 70 mm) are available upon request.

30 40 50 60 70

- Cord: standard length for cord control is 1000 mm, other dimensions are available upon request.- Rod: standard length for rod control is 1000 mm, other dimensions are available upon request. The rod can be powdercoated in

any RAL or Syntha Pulvin colour upon request. Also rod control with hook-up, with transmission and with sliding knob are availa-ble for certain vents (e.g. THM90EVO).

- Motor: possible by means of an ‘On/Off’ or a ‘0-10V’ (for home automation) switch. Standard cable length: 5m (except THL100(V), TL67-100-100PB, T67-100-130-150). The position of the cable exit for a Sonovent with motor control can be top left, top right, bottom left or bottom right.

- Not all control options are possible for all vents.

Finishing- Material internal and external profile: extruded AlMgSi 0.5 aluminium (according to EN 12020-2 and EN AW-6063)- Finishing internal and external profile: bronze or satin anodized (E6/EV1-SAA, except for Oxyvent and Sonovent range) or pow-

dercoated in any RAL or Syntha Pulvin colour (dual colour possible). Pre-treatment is recommended when used in an aggressive (in accordance with the standard Seaside Quality A) or a very aggressive (pre-anodisation) environment like sea-side, chemical industry, ...)

- Thermal bridge: extruded PVC (according to DIN 16941)- Material end caps: ASA polymer type Luran S (colour-fast, weather- and UV-resistant)- Colour end caps:

Overframe flap ventilators available in any colour upon request (dual colour possible), dyed in the mass or painted

Other flap ventilators black or white (and for AR75 also 1013, 1015, 7016, 7021, 7030, 7035, 7039, 8019, 9001, 9007), other colours available upon request

Sliding vents black

Slot vents black or white, depending on the type of slotvent

MaintenanceAlmost all the RENSON window vents have a removable inner part for ease of maintenance.Maintenance must be performed at least once a year. Clean the inside using a vacuum cleaner and/or damp cloth. Remove leaves and other dirt from the outside of the window vent. Clean the outside aluminium part with a damp cloth and a non-abrasive clea-ner. Rinse the window vent thoroughly with clean water.

Manual control Cord control Rod control Rod control Rod control Motor control

(hook-up with transmission with sliding knob

nr. 134) Nr. 135 Nr. 136

Additional info < Epilogue

Page 77: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

77

Epilogue > Additional info

Transom ProfilesTwo different transom profiles (height 35 mm or 62 mm) are available for the ventilators installed at transom. The transom pro-files are developed for easy and swift fabrication from bar lengths and are also available made to measure. These profiles can be satin anodised or powdercoated in any RAL or Syntha Pulvin colour. For the THM90EVO RENSON developed special types which do not require transom profiles; the THM90PBEVO for installation at the bottom of a window and the THM90TREVO for fully glazed-in installation between profiles (at transom).

THM90TR Sonovent® Compact with transom profile

35 62

Pollux: optional fine dust and pollen filterIf you live in a strongly fine dust-loaded environment (such as near a highway or an industrial area), or if you suffer from hay fever (caused by pollen), the supply of fresh and healthy air can still be guaranteed by installing the Pollux in your RENSON window ventilator.

The Pollux can be installed in these RENSON window vents:- the Invisivent EVO-range- AR60 / THK60- AR75- Sonovent (Compact / I / D)

Technical SpecificationsUpon simple request we can present you official test reports of all our window vents.Water- and windtightness is tested accordingly to EN 1027 and EN 1026.The RENSON products are manufactured according to, complies with and/or has been tested according to: EN ISO 140-10, EN ISO 717-1, EN 1026, EN 1027, EN 13141-1, EN 12020-2, EN AW 6063 T66, NBN D50-001, EN 10077-2, DIN 16491, prEN 1627, prEN 1628, prEN 1629, prEN 1630.

Patented technologyMost products in our standard range have unique features protected by patents, trademarks and worldwide intellectual property laws. Imitators and copycats will be prosecuted.

DisclaimerSyntha Pulvin is a registred trademark of Valspar Powder Coatings Limited.RENSON VENTILATION nv preserves the right to make technical changes without prior notice. Technical drawings and section details are not represented at scale 1:1.Colours, photos, technical drawings and specifications may deviate from the actual product. The latest version of this brochure can be downloaded from www.renson.eu.

Pollux

®

Page 78: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

78

Energy-saving ventilation� Constant natural supply of fresh air without draughts by means of a self-regulating flap in the ventilators.

� RENSON developed a mechanical ventilation system enabling extraction on demand of warm, polluted and humid air. This ‘extraction on demand’-system is energy-saving, since its integrated software controls the ventilation flaps in an intelligent way. Specifically, the system adapts (by means of sensors) the intensity of the air extraction in function of the air humidity and the CO

2-level in the various rooms of the house.

➊ SELF-REGULATING SUPPLY

Self-regulating ventilators such as...

➌EXTRACTION ON-DEMAND

Xtravent®Modus Healthbox® II Compact Healthbox® II

➋TRANSIT

Invisido®Silendo®

AR75 Sonovent®Invisivent® EVO AK Basic

How to ventilate in an energy-efficient residence?

Basic principles < Epilogue

Page 79: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

79

References

Page 80: Window ventilators4 Regulations < Introduction Brief guide to UK building regulations, part F - ventilation Domestic buildings New Buildings (with any design air permeability) Previously

© L

20

057

01

0

5/1

6

UK

/Ex

po

rt -

En

gli

sh

Dealer

RENSON®: your partner in ventilation and sun protection

RENSON®, headquartered in Waregem (Belgium), is a trendsetter in Europe in natural ventilation and sun protection. • Creating healthy spaces

From 1909, we’ve been developing energy efficient solutions assuring a healthy and comfortable indoor climate. Our remarkable headquarters - built according to the ‘Healthy Building Concept’ – is a beautiful example portraying our

corporate mission. • No speed limit on innovation

A multidisciplinary team of more than 80 R&D employees continually optimize our products and develop new and innovative concepts.

• Strong in communication Contact with the customer is of the utmost importance. A group of 100 in-the-field employees worldwide and a powerful international distribution network are ready to advise you on site. EXIT 5 at Waregem gives you the possibility to experience our products on your own and provides necessary training for installers.

• A reliable partner in business We can guarantee our customers optimal quality and service thanks to our environmentally friendly and modern production sites (with automated powder coating line, anodisation line, plastic injection moulding and mold making shop) covering an area of 95.000 m².

C r e a t i n g h e a l t h y s p a c e s

VENTILATION

SUNPROTECTION

OUTDOOR

RENSON® reserves the right to make technical changes to the products shown.The latest brochures may be downloaded from www.renson.eu

RENSON® Export Department • Tel. +32 (0)56 62 71 04 • [email protected]

RENSON® Headquarters IZ 2 Vijverdam • Maalbeekstraat 10 • 8790 Waregem • Belgium Tel. +32 (0)56 62 71 11 • Fax +32 (0)56 60 28 [email protected] • www.renson.eu

RENSON® Fabrications LTD Fairfax Units 1-5 • Bircholt Road • Parkwood Industrial Estate • Maidstone • Kent ME15 9SF Tel. 01622/754123 • Fax 01622/[email protected] • www.renson.eu