wfc cds walkthrough. emerson confidential 2 emerson confidential slide 2 intro this is a simple...
TRANSCRIPT
WFC CDS Walkthrough
Emerson Confidential • 2Emerson Confidential • Slide 2
Intro• This is a simple walkthrough or guide on how to fill out the Emerson WFC CDS• The WFC CDS is in Microsoft Excel format and is available through the link below
http://www2.emersonprocess.com/siteadmincenter/pm%20rosemount%20documents/00806-0200-4952.xlsm
Emerson Confidential • 3Emerson Confidential • Slide 3
Select request type
This is the only option for North America
Emerson Confidential • 4Emerson Confidential • Slide 4
Basic Customer Information
Mandatory Fields
Emerson Confidential • 5Emerson Confidential • Slide 5
Form NavigationOrange fields are clickable with changeable options
Any field with a red mark in top right corner means you can
hover over it and get more info
Emerson Confidential • 6Emerson Confidential • Slide 6
CDS is Divided Into 3 Main Sections
Section #1: Process Fluid Data
Se
ctio
n #
2: P
ipin
g
Sp
ecifi
catio
n Section #3: Basic Thermowell Information
Emerson Confidential • 7Emerson Confidential • Slide 7
Section #1: Process Fluid Data
Fluid Physical State is a drop
down
Units are drop
downs
This section only requires one of the three fields
completed
Emerson Confidential • 8Emerson Confidential • Slide 8
Section #2: Piping Specification
Default is line size & schedule with option to select
inside diameter & wall thickness
Select line size units
and SCH for schedule
Select line size first, then schedule
Emerson Confidential • 9Emerson Confidential • Slide 9
Section #2: Piping Specification
Hover over Piping Specification to get visual of
needed dimensions
Emerson Confidential • 10Emerson Confidential • Slide 10
Section #3: Basic Thermowell InformationScenario One: Standard Rosemount Model Number
Select “Yes” if you have a standard
Rosemount sensor or thermowell model
number
Enter full model
number here and that’s it
Emerson Confidential • 11Emerson Confidential • Slide 11
Section #3: Basic Thermowell InformationScenario Two: Non-standard thermowell
Select Mounting
Configuration
Leave blank for non-standard thermowell
Select Connection
Size
Select Stem Material
Emerson Confidential • 12Emerson Confidential • Slide 12
Section #3: Basic Thermowell InformationScenario Two: Non-standard thermowell
Enter stem dimensions;
Ls only needed for stepped stem
Hover over stem to get visual of needed
dimensions
Hover over bore to get visual of needed
dimensions
Hover over bore diameter and tip thickness to get standard Rosemount
dimensions
Emerson Confidential • 13Emerson Confidential • Slide 13
Section #3: Basic Thermowell InformationScenario Two: Non-standard thermowell
Hover over fillet to get visual of needed
dimensions
Enter fillet dimensions;
bs only needed for stepped stem
Select units for all dimensions
Area for extra notes or