Welcome to Heart Guard Technologies New Product Presentation. Company Structure. BRYAN SCHURKO – CEO STEPHEN CZERNIEJ –CFO JOHN AZER –VP OPERATIONS VAHID SHABABI –VP MARKETING. Background & Motivations. Why did we choose this Project? - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/1.jpg)
Welcome to Heart Guard Technologies
New Product Presentation
![Page 2: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/2.jpg)
Company Structure
• BRYAN SCHURKO – CEO
• STEPHEN CZERNIEJ –CFO
• JOHN AZER –VP OPERATIONS
• VAHID SHABABI –VP MARKETING
![Page 3: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/3.jpg)
Background & Motivations
• Why did we choose this Project?
• Why should you buy this product and not the similar one?– Cost Analysis– Functionality
![Page 4: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/4.jpg)
Time Line
• How We Approached?
• Why We finished On-Time (Maybe a bit early!!)
![Page 5: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/5.jpg)
Life Guarding and Rescue Scenarios
• What does a lifeguard do?
• How does a lifeguard deal with emergency situations?
• Vitals – Airway, Breathing, and Circulation
![Page 6: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/6.jpg)
Changes in the Lifesaving World
• Lifeguards are unable to find pulses in emergency situations creating stress and poor first aid assessments.
![Page 7: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/7.jpg)
New Protocol
• No check for Pulse/Circulation in victim assessment - considered ineffective.
• Give CPR to victims if not breathing ASAP, regardless of signs of circulation
![Page 8: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/8.jpg)
The Need to Find Circulation in a Victim for a Lifesaver/Rescuer
• To limit stress and shock for the rescuer.
• To ensure fast assessment and proper first aid for victims.
• To relay accurate and effective information to the paramedics.
![Page 9: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/9.jpg)
Hardware Overview• Waterproof box• Sensor circuit• PIC Microcontroller• LED display• Infrared Sensor• Audio Cable• Battery• Switch
![Page 10: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/10.jpg)
Waterproof box• Reasons for choosing this box:
1. Waterproof
2. Unique color that sticks out
3. Hard to break or crack (Better durability)
4. Easy access to internal components such as the battery, PIC, etc.
![Page 11: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/11.jpg)
Sensor CircuitS
igna
l IN
Sig
nal O
UT
![Page 12: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/12.jpg)
Filter
• Contains capacitors and resistors of certain value, designed to filter out noise picked up from the surroundings
![Page 13: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/13.jpg)
Main Sensor Circuit
• Detects every heart pulse.• Major component is: LM6484 CMOS OpAmps
• Benefits:
1. Does not need a negative rail like most opamps, hence, only one battery is necessary for powering it.
2. Low power consumption.
3. Convert the input signal to a rectangular wave (simplifies signal analysis)
![Page 14: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/14.jpg)
One-Shot Timer
• Removes extra pulses in the digital signal coming
from the main sensor circuit.• Composed of a 555 timer
• Benefits:
1. Found in almost all electronic stores
2. Reliable
3. Easy to use
![Page 15: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/15.jpg)
PIC Microcontroller
• Analyses the signal coming out of the one-shot timer.• Benefits:
1. A group member (Bryan Schurko) was well experienced with this model.
2. Cheap compared to other microcontrollers
3. Provides many I/O’s
4. Low power consumption
Model: 16F877A
![Page 16: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/16.jpg)
LED Display• Heart pulse is displayed on a 7-segment
LED display.• Benefits:
1. Cheaper than an LCD display
2. Easier to program than an LCD
3. Consumes less power than an LCD
![Page 17: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/17.jpg)
Infrared Sensor
• Model: Cateye
• Clips onto human finger
• Contains Led infrared transmitter on one side, and a receiver on the other side.
• Other end of the sensor connects to an audio connector.
![Page 18: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/18.jpg)
Audio Cable
• The sensor jack goes into an audio cable.
• Audio cable goes through the box, into the sensor chip, for pulse detection.
![Page 19: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/19.jpg)
Battery
• 9V Alkaline Battery
• 5V voltage Regulator is used
to step down the 9V coming
out of the battery, into 5V,
which goes into the sensor
circuit.
![Page 20: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/20.jpg)
Switch
• External to the box
• Covered with a waterproof casing.
![Page 21: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/21.jpg)
System Overview
Ear sensorSignal Filter
and AmplifierCMOS Circuit
PIC Microcontroller
7-SegmentLED Display
External Internal Circuitry Display
![Page 22: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/22.jpg)
Infrared Pulse Sensor• Small non-invasive finger probe• Detects light levels by using a infrared LED
and photo-sensor– Hemoglobin absorbs photons, sensor detects this
![Page 23: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/23.jpg)
Analog Signal Conditioning• Small, noise prone signal output by sensor
• Intermediate circuit– Filters, amplifies, and converts to discrete levels
Original (Sensor) Signal Filtered/Amplified Signal Discrete Signal
![Page 24: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/24.jpg)
Processing: Microcontroller• PIC Microcontroller accepts digital signal from
circuit• Contains pulse error sensing algorithms• Averages previous 10 pulses to suppress errors
Detects PeriodDetermines if pulse width is adaquate
Average previous 10 proper pulses
Digital Signal To LED Display
![Page 25: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/25.jpg)
Processing: Error Suppression• If the pulses are outside of our defined range or pulse
widths are too small, the pulse will be ignored• Red light turns on when enough pulses are faulty
Signal going into PIC
Visual signal after error suppression
![Page 26: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/26.jpg)
Output: 7-Segment LED
• Output is displayed on three 7-segment displays
• Number displayed in beats per minute
![Page 27: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/27.jpg)
Conclusion
• Out Future Plans– Marketing and Sales
– Technical
![Page 28: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/28.jpg)
Salary
• Total Budget for this Phase $100,000– Bryan 25,000– Stephen 25,000– John 25,000– Vahid 25,000
• It was Based on– Collaboration
![Page 29: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/29.jpg)
We Would Like to Thank
• Dr. Andrew Rawicz
• Mr. Mike Sjoerdsma
• Mr. Brad Oldham
• Ms. Paris
![Page 30: Welcome to Heart Guard Technologies New Product Presentation](https://reader036.vdocuments.site/reader036/viewer/2022062321/56813d4d550346895da70730/html5/thumbnails/30.jpg)
• Bruce Warby - Biomedical Engineering Ridge Meadows Hospital
• Marge Czerniej - Registered Nurse at Ridge Meadows Hospital
• Jusytna Iwan - The Victim - 4th Year Criminology Undergrad
• John Czerniej - SFU Facilities Management • Dr. Ash Parames – Advisor
• Fred Heep - Engineering Lab Technician