weishaupt wm-g10 zm-pln gas burnersanjoseboiler.com/wp-content/uploads/2017/07/wm-10pln... ·...

5
The next-generation Low-NO x burner for ratings up to 1 MW with NO x emissions below 20 mg/Nm 3 That’s reliability. Weishaupt WM-G10 ZM-PLN gas burner

Upload: others

Post on 06-Aug-2020

2 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Weishaupt WM-G10 ZM-PLN gas burnersanjoseboiler.com/wp-content/uploads/2017/07/WM-10PLN... · 2017-07-21 · WM-G10 ZM-PLN: for extremely low NO x emission limits Weishaupt’s latest

The next-generation Low-NOx burner for ratings up to 1 MW with NOx emissions below 20 mg/Nm3

That’s reliability.

Weishaupt WM-G10 ZM-PLN gas burner

Page 2: Weishaupt WM-G10 ZM-PLN gas burnersanjoseboiler.com/wp-content/uploads/2017/07/WM-10PLN... · 2017-07-21 · WM-G10 ZM-PLN: for extremely low NO x emission limits Weishaupt’s latest

WM-G10 ZM-PLN:for extremely low NOx emission limits

Weishaupt’s latest burner model, the WM-G10 ZM-PLN, is for use whereextremely low NOx emission limitsare in force.

Broad range of applicationsThe burner meets all the requirementsof a wide variety of heat exchangers.

One particular advantage of this type ofcombustion system is that it can beused on appliances with particularlysmall combustion chambers, as well aswith more typical boilers.

Special mixing assembly To achieve the low-level NOx emissions,Weishaupt uses a well-thought-outcombination of premixing and surface-stabilised combustion.

The premixing ensures an homogeneousgas / air mixture and reliable ignition.Turndowns of 6:1 are achievable.

That’s reliabilityThe ignition electrodes and the ionisationprobes that serve as the primary flamesensor are both air cooled in order tosafeguard their reliability.

More safetyA UV flicker detector serves alongsidethe ionisation probes as an additionalflame sensor, resulting in an extremelyhigh degree of safety.

A second air pressure switch guardsagainst contamination of the combustionair and ensures the minimum air volumeis always available.

Well-thought-out detailsTo simplify installation, the burner flangeis mounted on the heat exchanger first,before the combustion surface is inserted.Likewise, with the burner hinged open, itis possible to replace the combustionsurface without completely dismountingthe burner from the heat exchanger.

The metal gauze air filter can be fittedwith an optional protective sleeve thatcan then be replaced once it becomesexcessively soiled.

The ceramic insulator, which is includedas standard, provides optimal heat shielding to the mixing assembly andthe electrode unit.

Advantages:

• The combustion surface can bewithdrawn through the mountedburner flange

• Air-cooled ignition and ionisationelectrode unit with sight glass forflame inspection

• Separate air pressure switches tomonitor the inlet air pressure andthe mixing pressure

• Flame monitoring via ionisationprobe and UV flicker detector forincreased safety

• W-FM 50 digital combustion manager (language neutral)

• Interference-free ignition unit

• Burner flange limit switch

• Silicone-free execution

• IP54 protection

• IE3 premium efficiency motor

Air inlet with metal gauze filter Air-cooled ignition and flame electrode unit withintegral sight glass for visual flame inspection

The air damper control has been designed to beparticularly aerodynamic

Page 3: Weishaupt WM-G10 ZM-PLN gas burnersanjoseboiler.com/wp-content/uploads/2017/07/WM-10PLN... · 2017-07-21 · WM-G10 ZM-PLN: for extremely low NO x emission limits Weishaupt’s latest

A ceramic insulator provides optimal heat shieldingto the mixing assembly and electrode unit

A microweave mat made from a high-quality alloy permits the right amount of gas / air mix to pass

Homogeneous, surface-stabilised combustion

11

mbar

10

9

8

7

6

5

4

3

2

1

0

-1

-2

-30 100 200 300 400 500 600 700 800 900 1.000 kW

9

01

mbar

11

3

4

5

6

7

8

9

-3

-2

-1

0

1

2

0 200001 004003 006005 008007 1.000009 kW1.000

Turndown

Natural gas 6:1LPG 5:1

Capacity chart (provisional)

WM-G10/2 ZM-PLN

NOx < 50 mg/Nm3 at 3% O2

Maximum rating 650 kW

NOx < 20 mg/Nm3 at 3% O2

Maximum rating 550 kW

WM-G10/3 ZM-PLN

NOx < 50 mg/Nm3 at 3% O2

Maximum rating 1 000 kW

NOx < 20 mg/Nm3 at 3% O2

Maximum rating 900 kW

Operation with NOx < 50 mg/Nm3 requires an O2 content of approximately 6 %. · Operation with NOx < 20 mg/Nm3 requires an O2 content of approximately 8 %.

Page 4: Weishaupt WM-G10 ZM-PLN gas burnersanjoseboiler.com/wp-content/uploads/2017/07/WM-10PLN... · 2017-07-21 · WM-G10 ZM-PLN: for extremely low NO x emission limits Weishaupt’s latest

That’s reliability

The next-generation Low-NOx burner for ratings up to 1 000 kW

Weishaupt WM-G10 ZM-PLN

Burner housing can be hinged

open to the left or right-hand side

Air inlet filter with metal gauze

Air pressure switch 1(inlet air)

Gas butterfly actuator

Ceramic insulator

Air damper actuator

Additional UV flicker detector for

increased safety

Ignition electrodeBurner motor with inbuilt contactor

Ionisation electrode tomonitor combustion

Air pressure switch 2(mixing pressure)

Burner mat made from a high-quality metal alloy

Integral sight glassfor visual flame inspection

Page 5: Weishaupt WM-G10 ZM-PLN gas burnersanjoseboiler.com/wp-content/uploads/2017/07/WM-10PLN... · 2017-07-21 · WM-G10 ZM-PLN: for extremely low NO x emission limits Weishaupt’s latest

Max Weis haupt GmbH88475 Schwen diTe l +49 7353 830 Fax +49 7353 83358www.weis haupt.de

Print No. 83216502, March 2016Printed in Germany. All rights reserved.

Germany:Augsburg BerlinBremenCologneDortmundDresdenErfurtFrankfurtFreiburgHamburgHanover KarlsruheKasselKoblenz

LeipzigMannheimMunichMünsterNeussNuremberg Regensburg Reutlingen Rostock Schwendi SiegenStuttgartTrierWangenWürzburg

Subsidiaries:BelgiumBosniaBrasil CanadaCroatiaCzech RepublicDenmarkFranceHungaryItalyPolandRomaniaSerbiaSlovakia

SloveniaSouth AfricaSwedenSwitzerland (E) United KingdomUSA Representation:BulgariaChinaLithuaniaAgencies:AlgeriaAustraliaAustriaBangladeh

CyprusEgyptEstoniaFinlandGreeceIndiaIndonesiaIranIrelandIsraelJapanJordanKorea (South)KuwaitLatvia

LebanonLuxembourgMalaysiaMacedoniaMoldovaMoroccoNetherlandsNew ZealandNigeriaNorwayPakistanPhilippinesPortugalRussiaSingapore

SpainSwitzerland (W)SyriaTaiwanThailandTunisiaTurkeyUkraineUAEVietnam

Branch offices across Germany and numeroussubsidiary companies, representatives andagents across the worldprovide local support.

Weishaupt worldwide: