water/wastewater/irrigation price list - tlp solutions · 2015-12-10 · danfoss will select a...

67
Water/Wastewater/Irrigation Price List www.danfossdrives.com MAKING MODERN LIVING POSSIBLE. Effective January 1, 2011 Revised 9/7/11

Upload: dinhnga

Post on 15-Jul-2018

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

Water/Wastewater/Irrigation Price List

www.danfossdrives.com

MAKING MODERN LIVING POSSIBLE.

Effective January 1, 2011Revised 9/7/11

Page 2: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

2 06/30/11

Danfoss Drives and Soft Starters

Contents

VLT® Micro Drive . . . . . . . . . . . . . . . . . . . . 3

VLT® 2800 Drive . . . . . . . . . . . . . . . . . . . . 4

VLT® AQUA Drives . . . . . . . . . . . . . . . . . . .6

Options and Accessories . . . . . . . . . . 27

MCD Soft Starters . . . . . . . . . . . . . . . . 36

VLT® Drive and Standard Panel Replacement Fuses . . . . . . . . . . . . . . . 38

DrivePro™ Service Programs . . . . . . . 59

General Conditions of Sale and Warranty . . . . . . . . . . . . . 66

Freight OptionsDanfoss offers three freight options:

1. Prepay and do not add

Eliminates the need for customers to select a carrier and manage separate freight invoices. Danfoss will select a non-expedited, ground carrier. All shipments are F.O.B. point of shipment.

VLT® AQUA Drives, Standard Panels, AHF Filters, MCD 200, and MCD 500 Soft Starters

Models Net price/unit Conditions1.2–106 FLAand demonstration unit

$65 NET 48 adjacent states$110 NET AK, HI, and Canada*

107–443 amp$120 NET 48 adjacent states$220 NET AK, HI, and Canada*

540–730 amp$550 NET 48 adjacent states

$1,100 NET AK, HI, and Canada*

VLT 2800, VLT Micro, drive accessories (shipped separately from the drive), spare parts

Models Net price/package ConditionsAll bare drives, accessories and parts

$20 NET 48 adjacent states—packages $40 NET AK, HI, and Canada*

Drives with standard option panels

$65 NET 48 adjacent states$110 NET AK, HI, and Canada*

Danfoss will package multiple parts and accessories in a single package when possible.

* Customs broker fees for Canada: $50 per shipment, G.S.T. additional. Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a broker and handle the brokerage fees directly.

2. Collect

The customer is responsible for selecting the carrier and indicating their choice on the purchase order. Danfoss will schedule the pick-up. The customer is responsible for paying the carrier for the shipment.

3. Prepay and add

Available for the following shipments:

• Expeditedshipments

• Productssuchascustompanelsandothersnotlistedabove

• Bulkshipmentsofspareparts

• Shipmenttoregionsotherthanthoselistedabove

• Shipmentsthatrequirespecializedpackagingortransporttypes

The customer may select a carrier or allow Danfoss to make the selection. Danfoss will pay the freight at the time of shipment and invoice the customer separately at the time of invoicing from the carrier.

Designations:

All prices are factory list prices in US$

— = Not available

nc = Standard, no charge

General Policy Information

Minimum Order

All orders are subject to a minimum billing of $100 NET. For information and Discount Schedule, please contact your Danfoss Representative or the factory.

Terms—NET 30 Days

Prices are subject to change without notice.

Freight

Danfoss reserves the right to select the freight carrier unless specified by the customer.

Page 3: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

3 06/30/11FCSI PL

VLT® Micro Drive

VLT Micro Drive List Price

M1 M2 M3 M4 M5

Remote mounting kit

LCP 12 with potentiometer

FC 51 MICRO 200 - 240VAC Single PhaseNema Size

230V Hp

Input Current

Output Current

Chassis/IP20Frame

Heat Output Watts

Part * Number ListW H D

1

1/4 3.3 1.22.8 5.9 5.8 M1

16 132F0001 $205 1/2 6.1 2.2 25 132F0002 $220

1 11.6 4.2 44 132F0003 $235 2 18.7 6.8 3.0 7.1 6.6 M2 67 132F0005 $290 3 26.4 9.6 3.5 9.4 7.6 M3 85 132F0007 $400

FC 51 MICRO 200 - 240VAC Three PhaseNema Size

230V Hp

Input Current

Output Current

Chassis/IP20Frame

Heat Output Watts

Part * Number ListW H D

1

1/3 2.4 1.52.8 5.9 5.8 M1

20 132F0008 $205 1/2 3.5 2.2 25 132F0009 $220

1 6.7 4.2 44 132F0010 $235 2 10.9 6.8 3.0 7.1 6.6 M2 67 132F0012 $290 3 15.4 9.6 3.5 9.4 7.6 M3 85 132F0014 $400 5 24.3 15.2 122 132F0016 $475

FC 51 MICRO 380-480VAC Three PhaseNema Size

460V Hp

Input Current

Output Current

Chassis/IP20Frame

Heat Output Watts

Part * Number ListW H D

1

1/2 1.7 1.1 2.8 5.9 5.8 M1 25 132F0017 $280 1 3 2.1 44 132F0018 $295 2 5.1 3.4 3.0 7.1 6.6 M2 56 132F0020 $400 3 7.3 4.8 81 132F0022 $470 4 9.9 6.3

3.5 9.4 7.6 M3

101 132F0024 $525 5 12.4 8.2 133 132F0026 $555

7.5 16.6 11 167 132F0028 $625 10 21.4 14 218 132F0030 $795

215 29 21 4.9 11.5 9.5 M4 342 132F0058 $1,115 20 31 27 454 132F0059 $1,420 25 36 34 6.5 13.2 M5 428 132F0060 $1,700

3 30 37.5 40 520 132F0061 $2,010

OptionsDescription Part Number List

VLT LCP 11 w/o potentiometer 132B0100 $23 VLT LCP 12 with potentiometer 132B0101 $23 Remote Mounting Kit for LCP 132B0102 $13

Nema 1 kit for M1 frame 132B0103 $8 Nema 1 kit for M2 frame 132B0104 $8 Nema 1 kit for M3 frame 132B0105 $8 Nema 1 kit for M4 frame 132B0120 $22 Nema 1 kit for M5 frame 132B0121 $25

De-coupling plate kit for M1 and M2 frames 132B0106 $8

De-coupling plate kit for M3 frame 132B0107 $8

Decoupling kit for M4 and M5 132B0122 $8

IP21 for M1 frame 132B0108 $13 IP21 for M2 frame 132B0109 $16 IP21 for M3 frame 132B0110 $18

DIN rail mounting kit for M1 132B0111 $6

Line Filter MCC 107 Option for FC51 Part Number List

M1 200-240v 1ø - .25-.50 HP 130B2522 $80 M1 200-240v 1ø - 1 HP 130B2533 $80

M1 200-480v 3ø - .25 - 1 HP 130B2523 $80

M2 200-240v 1ø - 2 HP 130B2525 $135 M2 380-480v 3ø - 2 HP 130B2524 $135

M2 200-240v 3ø- 1.5 - 2 HP & 380-480v 3ø - 3 HP 130B2526 $135

M3 200-240v 1ø - 3 HP 130B2530 $165 M3 200-240v 3ø - 4 HP &

380-480v 3ø - 7.5 HP 130B2528 $165

M3 200-240v 3ø - 3 HP & 380-480v 3ø - 5 HP 130B2531 $165

M3 200-240v 3ø - 5 HP & 380-480v 3ø - 10 HP 130B2527 $165

M3 380-480v 3ø - 4.0 HP 130B2529 $165

*Need to order LCP

Page 4: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

4 06/30/112800 PL

[1] Power Size* 2803 0.5 HP2805 0.75 HP2807 1 HP2811 1.5 HP2815 2 HP2822 3 HP2830 4 HP2840 5 HP2855 7.5 HP2875 10 HP2880 15 HP2881 20 HP2882 25 HP

[2] AC Line Supply D2** 230 VAC, 1Ø or 3Ø (0.5 to 2 HP only)S2*** 230 VAC, 1Ø (0.5 to 2 HP only)T2 200-240 VAC, 3Ø (3 and 5 HP only)T4 380-480 VAC, 3Ø (0.75 to 25 HP)

* Power sizes 2803 thru 2875 provided in a protected chassis (IP 20); 2880 thru 2882 are NEMA 1

** Cannot be ordered with RFI Filter.*** Must be ordered with RFI Filter

How to Order:Select one item from each of the feature code blocks to complete a part number.

VLT® 2800 Drive

[3] Hardware ST Standard SB Standard with Brake

[4] RFI Filter R0 Without FilterR1 With Built-in 1A FilterR3 With Built-in 1B Filter

[5] Fieldbus OptionsF00 Without Fieldbus F10 With Profibus DPF12 With Profibus DP (12 MB)F30 With DeviceNet

VLT 2800 Series Drive List Price VLT 28_ _ -P -D2 -B20 -ST -R0 -DB -F00 -C0

Power Size HpOutput Amps List Price Brake

RFI Filter R0 R1 R3

220-240V 1 or 3 phase VLT 2803 D2 0.5 2.2 $415 $30 std $135 — VLT 2805 D2 0.75 3.2 $439 $30 std $135 — VLT 2807 D2 1 4.2 $450 $30 std $135 — VLT 2811 D2 1.5 6 $500 $40 std $145 — VLT 2815 D2 2 6.8 $545 $40 std $145 — VLT 2822 D2 3 9.6 $650 $40 — $145 — VLT 2840 D2 5 16 $1,150 $55 — $155 —

220-240V 1 phase VLT 2803 S2 0.5 2.2 $550 $30 — $135 — VLT 2805 S2 0.75 3.2 $574 $30 — $135 — VLT 2807 S2 1 4.2 $585 $30 — $135 — VLT 2811 S2 1.5 6 $645 $40 — $145 — VLT 2815 S2 2 6.8 $690 $40 — $145 —

200-240V 3 phaseVLT 2822 T2 3 9.6 $646 $40 std $145 — VLT 2840 T2 5 16 $820 $55 std $160 —

380-480V 3 Phase VLT 2805 T4 0.75 1.7 $390 $30 std $135 — VLT 2807 T4 1 2.1 $440 $30 std $135 — VLT 2811 T4 1.5 3 $485 $40 std $145 — VLT 2815 T4 2 3.7 $535 $40 std $145 — VLT 2822 T4 3 5.2 $630 $40 std $145 — VLT 2830 T4 4 7 $730 $55 std $160 — VLT 2840 T4 5 9.1 $799 $55 std $160 — VLT 2855 T4 7.5 12 $930 $70 std $205 — VLT 2875 T4 10 16 $1,075 $70 std $205 —

VLT 2880 - Nema 1 T4 15 24 $1,375 $100 std — $245 VLT 2881 - Nema 1 T4 20 32 $1,620 $100 std — $245 VLT 2882 - Nema 1 T4 25 37.5 $2,050 $100 std — $245

FieldBus adder F00 Without Fieldbus std

F10 With Profibus DP (3 MB) $250 F12 With Profibus DP (12 MB) $225

F30 With DeviceNet $195

Page 5: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

5 06/30/112800 PL

VLT 2800 Series Options and Accessory List Price

VLT® 2800 Drive

RFI Filter R0 Without Filter R1 With Built-in A1 Filter R3 With Built-in B1 Filter

Fieldbus Options F00 Without Fieldbus F10 With Profibus DP (3 MB) F12 With Profibus DP (12 MB) F30 With DeviceNet

AC Line Voltage D2** 230 VAC, 1Ø or 3Ø, (0.5 to 5 HP only) S2† 230 VAC, 1Ø (0.5 to 2 HP only) T2 200–240 VAC, 3Ø (3–5 HP only) T4 380–480 VAC, 3Ø (0.75 to 25 HP)

Accessory List Prices

Local Control Panel List Price 175N0131 LCP-2 keypad $176 175Z0850 LCP remote mounting kit $60 175Z0929 Cable only (10’) $36

Nema 1 Kit List Price 195N1900 For VLT 2803–2815 $31 195N1901 For VLT 2822–2830; VLT 2840 (460V only) $30 195N1902 For VLT 2840 (230V only); VLT 2855 and 2875 $75

Add on modules List Price

195N3100 RFI B1/LC Filter For VLT 2803–2805 (230V); VLT 2807–2815 (460V) $368

195N3101 RFI B1/LC Filter For VLT 2807–2822 (230V); VLT 2822–2840 (460V) $384

195N3103 RFI B1 Filter For VLT 2803–2840 (230V); VLT 2803–2875 (460V) $120

195N3110 Motor Coil For VLT 2803–2840 (230V); VLT 2803–2875 (460V) $368

VLT 2800 Dimensions

VLT 2803-2815 (1/2-2HP) 200-240 VAC VLT 2822 (T2) 3HP / 3ø 200-240 VAC VLT 2805-2815 (3/4-2HP) 380-480 VAC VLT 2822-2840 (3-5 HP) 380-480 VAC

Protected Chassis / IP20 [mm] Protected Chassis / IP20 [mm] Height 7.9 in. [200] 10.5 in. [268] Width 3.0 in. [75] 3.5 in. [90] Depth 6.6 in. [168] 6.6 in. [168]

VLT 2822 (3HP) 1ø/ 3ø 220-240 VAC VLT 2840 (T2) (5HP) 3ø 200-240 VAC VLT 2840 (5HP) 1ø/3 ø 200-240 VAC VLT 2855-2875 (7.5-10 HP) 380-480 VAC VLT 2880-2882(15-25HP) 380-480 VAC

Protected Chassis / IP20 [mm] Protected Chassis / IP20 [mm] Height 10.5 in. [268] 19.9 in. [505] Width 5.5 in. [140] 7.9 in. [200] Depth 6.6 in. [168] 9.6 in. [244]

Power Size* 2803 0.5 HP 2805 0.75 HP 2807 1 HP 2811 1.5 HP 2815 2 HP 2822 3 HP 2830 4 HP 2840 5 HP 2855 7.5 HP 2875 10 HP 2880 15 HP 2881 20 HP 2882 25 HP

*Powersizes2803–2875providedinaprotected chassis (IP 20); 2880–2882 are NEMA 1

** Cannot be ordered with RFI Filter

† Must be ordered with RFI Filter

Page 6: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

6 06/30/11FC200 PL

VLT® AQUA Drive

Overall Dimensions (in) Weight lbs (kg)

Chassis/IP20 Chassis/IP00 A2 (2) A3 (2) B3 B4 C3 C4 D3 D4 E2

Height 10.6 10.6 16.5 23.7 25.0 31.7 39.3 50.3 59.0

Widthw/out C option 3.5 5.1

6.5 9.1 12.1 14.6 16.1 16.1 23.0w/ C option 5.1 6.7w/ two C options 5.9 7.5

Depthw/out A or B option 8.1 8.1

9.8 9.5 13.1 13.1 14.7 14.7 19.4w/ A or B option 8.6 8.6

NEMA Type 1/IP21B1 B2 C1 C2 D1 D2 E1 F1 (3) F3 (3)

Height 18.9 25.6 26.8 30.3 45.6 60.6 78.7 89.8 89.8Width 9.5 9.5 12.1 14.6 16.5 16.5 23.6 55.1 78.6Depth 10. 3 10.3 12.2 13.2 14.7 14.7 19.4 23.9 23.9

NEMA Type 12/IP55 NEMA 4X/IP66 NEMA Type 12/IP54

A4 A5 B1 B2 C1 C2 D1 D2 E1 F1 (3) F3 (3)

Height 14.17 16.5 18.9 25.6 26.8 30.3 45.6 60.6 78.7 89.8 89.8Width 7.87 9.5 9.5 9.5 12.1 14.6 16.5 16.5 23.6 55.1 78.6Depth 7.5 7.9 10.3 10.3 12.2 13.2 14.7 14.7 19.4 23.9 23.9

(2) An optional NEMA Type 1 kit is available for A2 and A3 frames, which adds 4 inches to height. The Optional NEMA Kit weighs 1.3 lbs (0.6 kg)

(3) CertainoptionsforFframedrivesrequiretheadditionofanoptionscabinet,whichadds15.9”tothe width. With the additional options cabinet, an F1 becomes an F3 and an F2 becomes an F4.

TheVLT®AQUADriveSeriesisorganizedintosixcabinetframesizesdesignatedbytheletters A thru F.

Theseframesizesarefurthersubdividedwith numbered designations depicting cabinet functionality, enclosure rating, etc. (Note the color codes used to indicate the variousframesizes.Thesecolorsareusedthroughout this section to help with product identification.)

VLT® AQUA Drives are divided into six lettered frame sizes with multiple numbered sublevels. Note that all frame size configurations are not shown.

Frame Size lbs (kg)A2 (2) 10.4 – 10.8 (4.7 – 4.9)A3 (2) 14.3 – 14.6 (6.5 – 6.6)

A4 21.4 - 22.5 (9.7 - 10.2)A5 29.8 – 31.3 (13.5 – 14.2)

B1 51 (23)B2 60 (27)B3 26 – 30 (12 – 14)B4 53 (24)

C1 95 – 99 (43 – 45)C2 134 – 143 (61 – 65)C3 77 (35)C4 110 (55)

D1 210 – 229 (96 – 104)D2 276 – 333 (125 – 152)D3 181 – 201 (82 – 91)D4 247 –304 (112 – 138)

E1 487 – 611 (221 – 277)E2 487 – 611 (221 –277)

F1 (3) 2214 (1004)F2 (3) 2748 (1246)F3 (3) 2214 (1004)F4 (3) 2748 (1246)

E1

E2

D2

D1

D3

D4

C2C1B2B1A5A4A3A2

F1

Page 7: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

7 06/30/11FC200 PL

VLT® AQUA Drive

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

[1] Performance Level202 AQUA Drive

[2] Power SizePK25 – P1M2

0.33 HP (0.25 kw) – 1200 kw

[3] AC Line VoltageS2 1Ø 200/240 VACS4 1Ø 380/480 VACT2 3Ø 200/240 VACT4 3Ø 380/480 VACT6 3Ø 525/600 VACT7 3Ø 525/690 VAC

[4] EnclosureC00 Corrosion resistant

chassis/IP00E20 Protected chassis/IP20E/P21 NEMA 1/IP21E54 NEMA 12/IP54E/P55 NEMA 12/IP55E66 NEMA 4X/IP66

[5] RFI FilterH1 Integral class A1 and B1 RFIH2 Integral class A2 RFIH3 Integral class A1 and B1 RFI

[6] BrakingX Safe StopB Brake with Safe Stop brake IGBT (brake

resistor sold separately)T Safe Stop terminalU Brake IGBT with Safe Stop terminal

(brake resistor sold separately)

[8] Conformal CoatingFC202 PCB’s are always coated - the degree of protection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains InputX No optionA Fuses and loadsharingD Loadsharing terminals1 Mains disconnect3 Mains disconnect & fuses5 Mains disconnect, fuses

and loadsharing7 Fuses

[13] Fieldbus PriceAX No fieldbus ncA0 Profibus MCA101 $275A4 DeviceNet MCA104 $275

AN Ethernet IP MCA121 $435

AQ Modbus TCP/IP MCA 122 $435 AL Profinet $435

[14] Application Option PriceBX No application option ncB4 PTC Sensor Input MCB 114 $140BO Analog IO + battery backup

MCB109$225

BK General purpose I/O MCB101

$180

BY Extended cascade control $1100BP Relay expansion MCB105 $175

[15] Motion Control PriceCX No motion control option nc

[16] Advanced Cascade Control

Price

X No cascade control option ncS Advanced cascade $1695

[17] Voltage Input PriceDX No DC input ncD0 24 VDC option MCB107 $100

Refer to specific frame size pages for selection, availability, & pricing

9/7/11

Page 8: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

8 06/30/11FC200 PL

VLT® AQUA Drive

HP

Current [A] Est. Power Loss @ Rated

Max. Load (W)

Enclosure Rating/Frame Size (1)

Protected Chassis

IP20NEMA 1

IP21NEMA 12

IP55 IP66Output Input

Cont. Int. Cont. Int.1/3 1.8 2.9 1.6 2.6 21

A2 A2 A4 A4

1/2 2.4 3.8 2.2 3.5 293/4 3.5 5.6 3.2 5.1 42

1 4.6 7.4 4.1 6.6 541-1/2 6.6 7.3 5.9 6.5 63

2 7.5 8.3 6.8 7.5 823 10.6 11.7 9.5 10.5 1164 12.5 13.8 11.3 12.4 155

A3 A3 A5 A55 16.7 18.4 15.0 16.5 185

7-1/2 24.2 26.6 22.0 24.2 269B3 B1 B1 B110 30.8 33.9 28.0 30.8 310

15 46.2 50.8 42.0 46.2 44720 59.4 65.3 54.0 59.4 602

B4B2 B2 B2

25 74.8 82.3 68.0 74.8 737C1 C1 C130 88.0 96.8 88.0 88.0 845

C340 115 127 104 114 114050 143 157 130 143 1353

C4 C2 C2 C260 170 187 154 169 1636

Note:110%TorqueOverloadisratedfor60seconds. (1) Refer to page 8 for dimensions.

200 – 240 VAC 3Ø

C1C2

C3

D3

C4

D4

D1

D2

E1

F1

F2

E2

A2 A3

A5B1

B2

B3

B4

F4

F3

A4

VLT AQUA Drives are available in numerous enclosure framesizesillustratedatrightandinseveralpowerrangesshown in the charts on the following pages.

HP

Current [A] Est. Power Loss @ Rated

Max. Load (W)

Enclosure Rating/Frame Size (1)

NEMA 1 IP21

NEMA 12 IP55

Type 4X IP66

Output InputCont. Int. Cont. Int.

1-1/2 6.6 7.3 12.5 13.8 44 A3 A5 A52 7.5 8.3 15.0 16.5 30

B1 B1 B13 10.6 11.7 20.5 22.6 444 12.5 13.8 24.0 26.4 605 16.7 18.4 32.0 35.2 74

7-1/2 24.2 26.6 46.0 50.6 11010 30.8 33.4 59.0 64.9 150 B2 B2 B220 59.4 65.3 111.0 121.1 300 C1 C1 C130 88.0 96.8 172.0 189.2 440 C2 C2 C2

200 – 240 VAC 1Ø

Page 9: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

9 06/30/11FC200 PL

VLT® AQUA Drive

HP

Est. Power Loss @

Rated Max. Load (W)

Enclosure Rating/Frame Size (1)

Current [A]Protected

Chassis IP20

NEMA 1 IP21

NEMA 12 IP55 IP66

Output InputCont. Int. Cont. Int.

1/2 1.2 1.9 1.0 1.6 35

A2 A2 A4 A4

3/4 1.6 2.6 1.4 2.2 421 2.1 3.4 1.9 3.0 46

1-1/2 2.7 3.0 2.7 4.1 582 3.4 3.7 3.1 3.4 623 4.8 5.3 4.3 4.7 884 6.3 6.9 5.7 6.3 1165 8.2 9.0 7.4 8.1 124

7-1/2 11.0 12.1 9.9 10.9 187A3 A3 A5 A5

10 14.5 15.4 13.0 14.3 25515 21 23.1 19 20.9 278

B3 B1 B1 B120 27 29.7 25 27.5 39225 34 37.4 31 34.1 46530 40 44 36 39.6 525

B4B2 B2 B2

40 52 61.6 47 51.7 69850 65 71.5 59 64.9 739

C1 C1 C160 80 88 73 80.3 843C3

75 105 116 95 105 1083100 130 143 118 130 1384

C4 C2 C2 C2125 160 176 145 160 1474

380 – 480 VAC 3Ø

380 – 480 VAC 1Ø

HP

Current [A] Est. Power Loss @

Rated Max. Load (W)

Enclosure Rating/Frame Size (1)

Chassis IP00

NEMA 1 IP21

NEMA 12 IP54

Output InputCont. Int. Cont.

150 190 209 185 2947D3 D1 D1

200 240 264 231 3665250 302 332 291 4063

D4 D2 D2300 361 397 348 4652350 443 487 427 5634450 540 594 531 6082

E2 E1 E1500 590 649 580 6953600 678 746 667 8089650 730 803 718 8803700 780 858 759 9414

— F1 or F3 F1 or F3750 890 979 867 11006900 1050 1155 1022 12353

1000 1160 1276 1129 140411200 1380 1518 1344 17137

— F2 or F4 F2 or F41350 1530 1683 1490 17752

Note:110%TorqueOverloadisratedfor60seconds.(1) Refer to page 8 for dimensions. (2) Contact Danfoss.

HP

Est. Power Loss @

Rated Max. Load (W)

Enclosure Rating/Frame Size (1)

Current [A]

NEMA 1 IP21

NEMA 12 IP55

Type 4XIP66

Output InputCont. Int. Cont. Int.

10 14.5 15.4 30.0 33.0 300 B1 B1 B1

15 21.0 23.1 41.0 46.0 440 B2 B2 B2

25 34.0 37.4 72.0 79.2 740 C1 C1 C1

50 65.0 71.5 135.0 148.0 1480 C2 C2 C2

Page 10: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

10 06/30/11FC200 PL

VLT® AQUA Drive

HP

Current [A] Est. Power Loss @ Rated

Max. Load (W)

Enclosure Rating/Frame Size (1)

Protected Chassis

IP20NEMA 1

IP21NEMA 12

IP55 IP66Output Input

Cont. Int. Cont. Int.1 1.7 1.7 35

A3 A3 A5 A5

1-1/2 2.4 2.6 2.4 2.7 502 2.7 3.0 2.7 3.0 653 3.9 4.3 4.1 4.5 924 4.9 5.4 5.2 5.7 1225 6.1 6.7 5.8 6.4 145

7-1/2 9.0 9.9 8.6 9.5 19510 11.0 12.1 10.4 11.5 26115 18 20 17.2 19 300

B3 B1 B1 B120 22 24 20.9 23 40025 27 30 25.4 28 47530 34 37 32.7 36 525

B4 B2 B2 B240 41 45 39 43 70050 52 57 49 54 75060 62 68 59 65 850

C3 C1 C1 C175 83 91 78.9 87 1100

100 100 110 95.3 105 1400C4 C2 C2 C2

125 131 144 124.3 137 1500

525 – 600 VAC 3Ø

Note:110%TorqueOverloadisratedfor60seconds.(1) Refer to page 8 for dimensions.

Page 11: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

11 06/30/11FC200 PL

VLT® AQUA Drive

kWVoltage Range

Est. Power Loss @ Rated

Max. Load (W)

Frame Size

Protected Chassis

IP20NEMA 1

IP21NEMA 12

IP55 IP66Output Input

Cont. Int. Cont. Int.11 551-690 14.0 14.3 15.0 16.5 201

NA B2 B2 NA15 551-690 18.0 19.8 19.5 21.5 28518 551-690 22.0 24.2 24.0 26.4 33522 551-690 27.0 29.7 29.0 31.9 37530 551-690 34.0 37.4 36.0 39.6 43037 551-690 41.0 45.1 49.0 53.9 592

NA C2 C2 NA45 551-690 52.0 57.2 59.0 64.9 72055 551-690 62.0 68.2 71.0 78.1 88075 551-690 83.0 91.3 87.0 95.7 120090 551-690 100.0 110.0 99.0 108.9 1440

525 – 690 VAC 3Ø

525 – 690 VAC 3Ø

Note:110%TorqueOverloadisratedfor60seconds.(2) Contact Danfoss.

HP kW

Current [A] (@ 575V Nominal) Est. Power

Loss @ Rated Max. Load

(W)

Enclosure Rating/Frame Size (2)

Chassis IP00

NEMA 1 IP21

NEMA 12 IP54

Output InputCont. Int. Cont.

50 45 54 59 58 1043

D3 D1 D1

60 55 73 80 74 121775 75 86 95 85 1350

100 90 108 119 106 1599125 110 131 144 124 1891150 132 155 171 151 2230200 160 192 211 189 2617250 200 242 266 234 3197

D4 D2 D2300 250 290 319 286 3757350 315 344 378 339 4307400 400 400 440 390 4756450 450 450 495 434 4974

E2 E1 E1500 500 500 550 482 5623600 560 570 627 549 7018650 630 630 693 607 7793750 710 730 803 711 8933

F1 or F3 F1 or F3 F1 or F3950 800 850 935 828 10310

1050 900 945 1040 920 116921150 1000 1060 1166 1032 129091350 1200 1260 1386 1227 176021550 1400 1415 1557 1378 18173

Page 12: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

12 06/30/11FC200 PL

VLT® AQUA DriveSingle Phase Input FC 202 AQUA

200 - 240 V Single Phase - S2

Base Price Includes

Graphical Keypad

ADDITIONAL PRICES

Enclosure Hardware

RFIIP20

ChassisIP21

Nema 1IP55

Nema 12IP66

Nema 4X A2 A1 / B1[8]

CoatingMains

Disconnect

HP FLA FC 202 Frame E20 E21 E55 E66 H2 H1 C 1

1 1/2 6.6 P1K1 A3/A5 $999 std 60 $150 $365 std $120

$150

$195

2 7.5 P1K5

B1

$1,050 #N/A! std $370 $620 std $135 $295

3 10.6 P2K2 $1,195 #N/A! std $370 $620 std $150 $295

4 12.5 P3K0 $1,795 #N/A! std $370 $620 std $280 $295

5 16.7 P3K7 $1,995 #N/A! std $370 $620 std $290 $295

7.5 24.2 P5K5 $2,295 #N/A! std $370 $620 std $330 $295

10 30.8 P7K5 B2 $2,695 #N/A! std $510 $850 std $430 $295

20 59.4 P15K C1 $4,695 #N/A! std $765 $1,375 std $710 $435

30 88 P22K C2 $6,895 #N/A! std $1,000 $1,795 std $975 $660

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - S2 - - H2 - X - G - - - X - X - SXXX - X - - - - -

[13] Fieldbus PriceAX No fieldbus ncA0 Profibus MCA101 $275A4 DeviceNet MCA104 275

AN Ethernet IP MCA121 435

AQ Modbus TCP/IP MCA 122 435 AL Profinet 435

[14] Application Option PriceBX No application option ncB4 PTC Sensor Input MCB 114 $140BO Analog IO + battery backup

MCB109$225

BK General purpose I/O MCB101

180

BY Extended cascade control 100BP Relay expansion MCB105 175

[15] Motion Control PriceCX No motion control option nc

[16] Advanced Cascade Control

Price

X No cascade control option ncS Advanced cascade $149

[17] Voltage Input PriceDX No DC input ncD0 24 VDC option MCB107 $100

Page 13: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

13 06/30/11FC200 PL

VLT® AQUA Drive

380 - 480 V Single Phase - S4

ADDITIONAL PRICES

Enclosure Hardware

Base Price Includes

Graphical Keypad

RFI

IP20 Chassis

IP21 Nema 1

IP55 Nema 12

IP66 Nema 4X A2 A1/B1 [8]

CoatingMains

Disconnect

HP FLA FC 202 Frame E20 E21 E55 E66 H2 H1 C 1

10 15 P7K5 B1 $2,532 #N/A! std $370 $620 std $290

$150

$315

15 21 P11K B2 $3,728 #N/A! std $510 $850 std $375 $315

25 34 P18K C1 $5,300 #N/A! std $765 $1,375 std $440 $460

50 65 P37K C2 $8,824 #N/A! std $1,000 $1,795 std $940 $700

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - S4 - - H2 - X - G - - - X - X - SXXX - X - - - - -

Single Phase Input FC 202 AQUA

[13] Fieldbus PriceAX No fieldbus ncA0 Profibus MCA101 $275A4 DeviceNet MCA104 275

AN Ethernet IP MCA121 435

AQ Modbus TCP/IP MCA 122 435 AL Profinet 435

[14] Application Option PriceBX No application option ncB4 PTC Sensor Input MCB 114 $140BO Analog IO + battery backup

MCB109$225

BK General purpose I/O MCB101

180

BY Extended cascade control 100BP Relay expansion MCB105 175

[15] Motion Control PriceCX No motion control option nc

[16] Advanced Cascade Control

Price

X No cascade control option ncS Advanced cascade $149

[17] Voltage Input PriceDX No DC input ncD0 24 VDC option MCB107 $100

Page 14: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

14 06/30/11FC200 PL

VLT® AQUA Drive

A2A3A4A5

For Common Options see page 7.

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Options

Frame Base E20 E21 Frame E55 E66 P55 Frame Y55 Z55 Y66 Z66 H1 H2 H3

200

- 240

VA

C—T2

1/3 1.8 PK25 A2 $559 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $50 nc $35 1/2 2.4 PK37 A2 $583 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $55 nc $35 3/4 3.5 PK55 A2 $600 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $60 nc $40

1 4.6 PK75 A2 $613 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $70 nc $50 1-1/2 6.6 P1K1 A2 $655 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $80 nc $60

2 7.5 P1K5 A2 $698 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $95 nc $70 3 10.6 P2K2 A2 $772 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $115 nc $85 4 12.5 P3K0 A3 $850 nc $60 A5 $150 $365 $170 - - - - $130 nc $95 5 16.7 P3K7 A3 $928 nc $60 A5 $150 $365 $170 - - - - $140 nc $105

HP FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C 1 3 71/3 1.8 PK25 nc $40 $30 $70

nc

nc $130 $195 $350 $155 1/2 2.4 PK37 nc $45 $30 $75 nc $130 $195 $350 $155 3/4 3.5 PK55 nc $50 $30 $80 nc $130 $195 $350 $155

1 4.6 PK75 nc $55 $30 $85 nc $130 $195 $350 $155 1-1/2 6.6 P1K1 nc $60 $30 $90 nc $130 $195 $350 $155

2 7.5 P1K5 nc $70 $35 $105 nc $130 $195 $350 $155 3 10.6 P2K2 nc $85 $45 $130 nc $130 $195 $350 $155 4 12.5 P3K0 nc $95 $50 $145 nc $130 $195 $350 $155 5 16.7 P3K7 nc $105 $55 $160 nc $130 $195 $350 $155

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Options

Frame Base E20 E21 Frame E55 E66 P55 Frame Y55 Z55 Y66 Z66 H1 H2 H3

380-

480

VAC—

T4

1/2 1.2 PK37 A2 $583 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $55 nc $35 3/4 1.6 PK55 A2 $633 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $60 nc $40

1 2.1 PK75 A2 $682 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $70 nc $50 1-1/2 2.7 P1K1 A2 $735 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $80 nc $60

2 3.4 P1K5 A2 $789 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $95 nc $70 3 4.8 P2K2 A2 $846 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $115 nc $85 4 6.3 P3K0 A2 $925 nc $60 A5 $150 $365 $170 A4 $170 $150 $385 $365 $130 nc $95 5 8.2 P4K0 A2 $955 nc $60 A5 $150 $365 $170 $170 $150 $385 $365 $140 nc $105

7-1/2 11.0 P5K5 A3 $1,097 nc $60 A5 $150 $365 $170 - - - - $165 nc $120 10 14.5 P7K5 A3 $1,252 nc $60 A5 $150 $365 $170 - - - - $195 nc $140

HP FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C 1 3 71/2 1.2 PK37 nc $45 $30 $75

nc

nc $130 $195 $350 $155 3/4 1.6 PK55 nc $50 $30 $80 nc $130 $195 $350 $155

1 2.1 PK75 nc $55 $30 $85 nc $130 $195 $350 $155 1-1/2 2.7 P1K1 nc $60 $30 $90 nc $130 $195 $350 $155

2 3.4 P1K5 nc $70 $35 $105 nc $130 $195 $350 $155 3 4.8 P2K2 nc $85 $45 $130 nc $130 $195 $350 $155 4 6.3 P3K0 nc $95 $50 $145 nc $130 $195 $350 $155 5 8.2 P4K0 nc $105 $55 $160 nc $130 $195 $350 $155

7-1/2 11.0 P5K5 nc $120 $65 $185 nc $130 $195 $350 $155 10 14.5 P7K5 nc $140 $70 $210 nc $130 $195 $350 $155

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10*] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

Use the Performance Data Selection charts on pages 8-10 to determine the frame size and enclosure style availability for the selected Power Size [2}.

1/3 - 5 Hp 208 - 240 VAC1/2 - 10 Hp 380 - 480 VAC

1 - 10 Hp 525 - 600 VAC

A Frame Sizes

Page 15: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

15 06/30/11FC200 PL

VLT® AQUA Drive

(1) Mains Input options not available E20 enclosures—select X.

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Options

Frame Base E20 E21 Frame E55 E66 P55 Frame HX H2 H3

525

- 600

VAC

—T6

1 1.7 PK75 A3 $723 nc $60 A5 $150 $365 $170 - nc - -1-1/2 2.4 P1K1 A3 $753 nc $60 A5 $150 $365 $170 - nc - -

2 2.7 P1K5 A3 $813 nc $60 A5 $150 $365 $170 - nc - -3 3.9 P2K2 A3 $895 nc $60 A5 $150 $365 $170 - nc - -4 4.9 P3K0 A3 $995 nc $60 A5 $150 $365 $170 - nc - -5 6.1 P4K0 A2 $1,055 nc $60 A5 $150 $365 $170 - nc - -

7-1/2 9.0 P5K5 A3 $1,225 nc $60 A5 $150 $365 $170 - nc - -10 11.0 P7K5 A3 $1,375 nc $60 A5 $150 $365 $170 - nc - -

HP FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C 1 3 71 1.7 PK75 nc $50 $30 $80

nc

nc $130 $195 $350 $155 1-1/2 2.4 P1K1 nc $55 $30 $85 nc $130 $195 $350 $155

2 2.7 P1K5 nc $70 $35 $105 nc $130 $195 $350 $155 3 3.9 P2K2 nc $85 $45 $130 nc $130 $195 $350 $155 4 4.9 P3K0 nc $95 $50 $145 nc $130 $195 $350 $155 5 6.1 P4K0 nc $105 $55 $160 nc $130 $195 $350 $155

7-1/2 9.0 P5K5 nc $120 $65 $185 nc $130 $195 $350 $155 10 11.0 P7K5 nc $140 $70 $210 nc $130 $195 $350 $155

A2A3A5

Use the Performance Data Selection charts on pages 8-10 to determine the frame size and enclosure style availability for the selected Power Size [2}.

[1] Performance Level202 AQUA Drive

[2] Power Size(1)

PK25 0.33 HP (0.25 kW)PK37 0.5 HP (0.37 kW)PK55 0.75 HP (0.55 kW)PK75 1 HP (0.75 kW)P1K1 1.5 HP (1.1 kW)P1K5 2 HP (1.5 kW)P2K2 3 HP (2.2 kW)P3K7 5 HP (3.7 kW) (200-240 VAC only)P4K0 5 HP (4 kW) (380-480 VAC only)P5K5 7.5 HP (5.5 kW)P7K5 10 HP (7.5 kW)

[3] AC Line VoltageT2 3Ø 200 – 240 VACT4 3Ø 380 – 480 VAC T6 3Ø 525 - 600 VAC

[4] EnclosureE20 Protected chassis/IP20E21 NEMA 1/IP21E55 NEMA 12/IP55E66 NEMA 4X/IP66P55 NEMA 12/IP55 with backplateY55Z55Y66

NEMA 12/IP55 with backplate (A4 only)NEMA 12/IP55 (A4 only)NEMA 4X/IP66 with backplate (A4 only)

Z66 NEMA 4X/IP66 (A4 only)

[5] RFI FilterH1 Integral class A1 and B1 RFI filterH2 Integral class A2 RFI filterH3 Integral class A1 and B1 RFI filter

HX None (T6 only)

[6] BrakingX No brake IGBTB

T

Brake IGBT mounted (resistor sold separatelySafe stop terminal

U Safe stop with brake

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains Input (1) X No option1 Mains disconnect3 Mains disconnect and fuses7 Fuses

[10] Select “S” when using A5 or A4 enclosure.

1/3 - 5 Hp 208 - 240 VAC1/2 - 10 Hp 380 - 480 VAC

1 - 10 Hp 525 - 600 VAC

A Frame Sizes

For Common Options see page 7.

Page 16: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

16 06/30/11FC200 PL

VLT® AQUA Drive

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Option Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U

200

- 240

VAC

—T2

7-1/2 24.2 P5K5 B3 $1,165 nc - B1 $250 $370 $620 $270 $390 $265 nc $200 nc $120 $80 $200 10 30.8 P7K5 B3 $1,325 nc - B1 $250 $370 $620 $270 $390 $275 nc $210 nc $140 $95 $235 15 46.2 P11K B3 $1,480 nc - B1 $250 $370 $620 $270 $390 $315 nc $255 nc $170 $120 $290 20 59.4 P15K B4 $1,826 nc $30 B2 $340 $510 $850 $370 $540 $405 nc $350 nc $190 $165 $355

HP FLA SizeDisplay Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D7-1/2 24.2 P5K5

nc

nc $130 nc $295 $460 $580 $165 $415 $285 $120 10 30.8 P7K5 nc $130 nc $295 $460 $600 $165 $435 $305 $140 15 46.2 P11K nc $130 nc $295 $460 $610 $165 $445 $315 $150 20 59.4 P15K nc $130 nc $295 $580 $765 $285 $480 $470 $185

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Option Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U

380

- 480

VAC

—T4

15 21.0 P11K B3 $1,499 nc - B1 $250 $370 $620 $270 $390 $265 nc $200 nc $170 $80 $250 20 27.0 P15K B3 $1,834 nc - B1 $250 $370 $620 $270 $390 $275 nc $210 nc $190 $95 $285 25 34.0 P18K B3 $2,339 nc - B1 $250 $370 $620 $270 $390 $315 nc $255 nc $240 $120 $360 30 41.0 P22K B4 $2,750 nc $30 B2 $340 $510 $850 $370 $540 $355 nc $295 nc $275 $140 $415 40 52.0 P30K B4 $3,413 nc $30 B2 $340 $510 $850 $370 $540 $405 nc $350 nc $310 $165 $475

HP FLA Size

Display Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D15 21.0 P11K

nc

nc $130 nc $295 $460 $580 $165 $415 $285 $120 20 27.0 P15K nc $130 nc $295 $460 $600 $165 $435 $305 $140 25 34.0 P18K nc $130 nc $295 $460 $610 $165 $445 $315 $150 30 41.0 P22K nc $130 nc $295 $495 $670 $200 $470 $375 $175 40 52.0 P30K nc $130 nc $295 $580 $765 $285 $480 $470 $185

B1B2B3B4

Use the Performance Data Selection charts on pages 8-10 to determine the frame size and enclosure style availability for the selected Power Size [2}.

For Common Options see page 7.

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10*] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

7.5 - 20 Hp 208 - 240 VAC15 - 40 Hp 380 - 480 VAC15 - 50 Hp 525 - 600 VAC

B Frame Sizes

(1) Mains Input options not available E20 enclosures—select X.

Page 17: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

17 06/30/11FC200 PL

VLT® AQUA Drive

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Options Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 HX H2 H3 X B T U

15 –

50

Hp

525

– 60

0 VA

C—T6

15 18.0 P11K B3 $1,739 nc - B1 $250 $370 $620 $270 $390 nc - - nc $170 $80 $250 20 22.0 P15K B3 $2,175 nc - B1 $250 $370 $620 $270 $390 nc - - nc $190 $95 $285 25 27.0 P18K B3 $2,823 nc - B1 $250 $370 $620 $270 $390 nc - - nc $240 $120 $360 30 34.0 P22K B4 $3,340 nc $30 B2 $340 $510 $850 $370 $540 nc - - nc $275 $140 $415 40 41.0 P30K B4 $4,049 nc $30 B2 $340 $510 $850 $370 $540 nc - - nc $310 $165 $475 50 52.0 P37K B4 $5,111 nc $30 B2 $340 $510 $850 $370 $540 nc - - nc $390 $200 $590

HP FLA Size

Display Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D15 18.0 P11K

nc

nc $130 nc $295 $460 $580 $165 $415 $285 $120 20 22.0 P15K nc $130 nc $295 $460 $600 $165 $435 $305 $140 25 27.0 P18K nc $130 nc $295 $460 $610 $165 $445 $315 $150 30 34.0 P22K nc $130 nc $295 $495 $670 $200 $470 $375 $175 40 41.0 P30K nc $130 nc $295 $540 $725 $245 $480 $430 $185 50 52.0 P37K nc $130 nc $435 $720 $930 $285 $645 $495 $210

KW FLA Size

E21 w Graphic LCP Enclosure Options RFI Options Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H2 H4 H6 X B T U

525

- 690

VAC

—T7

11 18.0 P11K B2 $2,414 - - B2 nc $170 - $30 $200 nc $530 - nc $200 $80 $280 15 22.0 P15K B2 $2,703 - - B2 nc $170 - $30 $200 nc $545 - nc $220 $95 $315 18 27.0 P18K B2 $3,298 - - B2 nc $170 - $30 $200 nc $625 - nc $280 $120 $400 22 34.0 P22K B2 $3,796 - - B2 nc $170 - $30 $200 nc $705 - nc $315 $140 $455 30 41.0 P30K B2 $4,350 - - B2 nc $170 - $30 $200 nc $810 - nc $355 $165 $520

KW FLA Size

Display Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D11 18.0 P11K

nc

- nc nc $295 $460 $580 $165 $415 $285 $120 15 22.0 P15K - nc nc $295 $460 $600 $165 $435 $305 $140 18 27.0 P18K - nc nc $295 $460 $610 $165 $445 $315 $150 22 34.0 P22K - nc nc $295 $495 $670 $200 $470 $375 $175 30 41.0 P30K - nc nc $295 $540 $725 $245 $480 $430 $185

B1B2B3B4

(1) Mains Input options not available E20 enclosures—select X.

[1] Performance Level202 AQUA Drive

[2] Power SizeP5K5 7.5 HP (5.5 kW)P7K5 10 HP (7.5 kW)P11K 15 HP (11 kW)P15K 20 HP (15 kW)P18K 25 HP (18 kW)P22K 30 HP (22 kW)P30K 40 HP (30kW)P37K 50 HP (37 kW)

[3] AC Line VoltageT2 3Ø 200 – 240 VACT4 3Ø 380 – 480 VACT6 3Ø 525 - 600 VACT7 3Ø 525 - 690 VAC

[4] EnclosureE20 Protected chassis/IP20E21 NEMA 1/IP21E55 NEMA 12/IP55E66 NEMA 4X/IP66P20 Protected chassis/IP20 with backplateP21 NEMA 1/IP21 with backplateP55 NEMA 12/IP55 with backplate

[5] RFI FilterH1 Integral class A1 and B1 RFI filterH2 Integral class A2 RFI filterH3 Integral class A1 and B1 RFI filterH4 Integral class A1 and B1 RFI filterHX None (T6 only)

[6] BrakingX No brake IGBTB

T

Brake IGBT mounted (resistor sold separatelySafe stop terminal

U Safe stop with brake

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains Input (1)

X No option1 Mains disconnect3 Mains disconnect and fuses5 Mains disconnect, fuses and

loadsharing7 Fuses8 Mains disconnect and loadsharingA Fuses and loadsharingD Loadsharing terminals

[10] Select “S” when using B1 or B2 enclosure.

Use the Performance Data Selection charts on pages 8-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

For Common Options see page 7.

7.5 - 20 Hp 208 - 240 VAC15 - 40 Hp 380 - 480 VAC15 - 50 Hp 525 - 600 VAC

B Frame Sizes

Page 18: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

18 06/30/11FC200 PL

VLT® AQUA Drive

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Option Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U

200

- 240

VAC

—T2

25 74.8 P18K C3 $2,341 nc $35 C1 $615 $765 $1,375 $650 $800 $415 nc $365 nc $240 $200 $440 30 88.0 P22K C3 $2,948 nc $35 C1 $615 $765 $1,375 $650 $800 $495 nc $440 nc $275 $245 $520 40 115.0 P30K C3 $3,717 nc $35 C1 $615 $765 $1,375 $650 $800 $670 nc $595 nc $355 $295 $650 50 143.0 P37K C4 $4,559 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $885 nc $800 nc $450 $335 $785 60 170.0 P45K C4 $5,317 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $990 nc $905 nc $550 $400 $950

HP FLA SizeDisplay Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D25 74.8 P18K

nc

nc $255 nc $435 $910 $1,120 $475 $645 $685 $210 30 88.0 P22K nc $255 nc $435 $910 $1,130 $475 $655 $695 $220 40 115.0 P30K nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $255 50 143.0 P37K nc $255 nc $660 $1,305 - $645 - - $290 60 170.0 P45K nc $255 nc $660 $1,625 - $965 - - $335

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Option Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H1 H2 H3 X B T U

380

- 480

VAC

—T4

50 65.0 P37K B4 $4,135 nc $35 C1 $615 $765 $1,375 $650 $800 $415 nc $365 nc $390 $200 $590 60 80.0 P45K C3 $4,852 nc $35 C1 $615 $765 $1,375 $650 $800 $495 nc $440 nc $480 $245 $725 75 105.0 P55K C3 $5,765 nc $35 C1 $615 $765 $1,375 $650 $800 $670 nc $595 nc $575 $295 $870

100 130.0 P75K C4 $6,934 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $885 nc $800 nc $655 $335 $990 125 160.0 P90K C4 $8,365 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 $990 nc $905 nc $750 $400 $1,150

HP FLA SizeDisplay Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D50 65.0 P37K

nc

nc $255 nc $435 $910 $1,120 $475 $645 $685 $210 60 80.0 P45K nc $255 nc $435 $910 $1,130 $475 $655 $695 $220 75 105.0 P55K nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $255

100 130.0 P75K nc $255 nc $660 $1,305 - $645 - - $290 125 160.0 P90K nc $255 nc $660 $1,625 - $965 - - $335

C1C2C3C4

Use the Performance Data Selection charts on pages 8-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

For Common Options see page 7.

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

25 - 60 Hp 208 - 240 VAC50 - 125 Hp 380 - 480 VAC60 - 125 Hp 525 - 600 VAC

C Frame Sizes

(1) Mains Input options not available E20 enclosures—select X.

Page 19: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

19 06/30/11FC200 PL

VLT® AQUA Drive

HP FLA Size

E20 w Graphic LCP Enclosure Options RFI Option Brake Option

Size Base E20 P20 Frame E21 E55 E66 P21 P55 HX H2 H3 X B T U

525

– 6

00 V

AC—

T6

60 62.0 P45K C3 $6,001 nc $35 C1 $615 $765 $1,375 $650 $800 nc - - nc $480 $245 $725 75 83.0 P55K C3 $6,732 nc $35 C1 $615 $765 $1,375 $650 $800 nc - - nc $575 $295 $870

100 100.0 P75K C4 $8,162 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 nc - - nc $655 $335 $990 125 131.0 P90K C4 $9,806 nc $35 C2 $800 $1,000 $1,795 $835 $1,035 nc - - nc $750 $400 $1,150

HP FLA SizeDisplay Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D60 62.0 P45K

nc

nc $255 nc $435 $910 $1,130 $475 $655 $695 $220 75 83.0 P55K nc $255 nc $435 $1,000 $1,255 $565 $690 $820 $255

100 100.0 P75K nc $255 nc $660 $1,305 $645 - - $290 125 131.0 P90K nc $255 nc $660 $1,625 $965 - - $335

KW FLA Size

E20 w Graphic LCP Enclosure Options RFI Options Brake Option

Frame Base E20 P20 Frame E21 E55 E66 P21 P55 H2 H4 H6 X B T U

525

- 690

VAC

—T7

37 52.0 P37K C2 $5,728 - - C2 nc $200 - $35 $235 nc $840 - nc $480 $200 $680 45 62.0 P45K C2 $6,872 - - C2 nc $200 - $35 $235 nc $960 - nc $575 $245 $820 55 83.0 P55K C2 $8,046 - - C2 nc $200 - $35 $235 nc $1,055 - nc $655 $295 $950 75 100.0 P75K C2 $8,665 - - C2 nc $200 - $35 $235 nc $1,175 - nc $750 $335 $1,085 90 108.0 P90K C2 $9,822 - - C2 nc $200 - $35 $235 nc $1,310 - nc $835 $400 $1,235

KW FLA SizeDisplay Option Coating Mains Input Option (1)

G X C X 1 3 5 7 8 A D37 52.0 P37K

nc

- nc nc $825 $1,300 $475 - - $220 45 62.0 P45K - nc nc $825 $1,300 - $475 - - $255 55 83.0 P55K - nc nc $825 $1,390 - $565 - - $290 75 100.0 P75K - nc nc $1,190 $1,835 - $645 - - $335 90 108.0 P90K - nc nc $1,190 $2,155 - $965 - - $375

C1C2C3C4

(1) Mains Input options not available E20—select X.

[1] Performance Level202 AQUA Drive

[2] Power SizeP37K 50 HP (37 kW)P45K 60 HP (45 kW)P55K 75 HP (55 kW)P75K 100 HP (75 kW)P90K 125 HP (90 kW)

[3] AC Line VoltageT2 3Ø 200 – 240 VACT4 3Ø 380 – 480 VACT6 3Ø 525 - 600 VACT7 3Ø 525 - 690 VAC

[4] EnclosureE20 Protected chassis/IP20E21 NEMA 1/IP21E55 NEMA 12/IP55E66 NEMA 4X/IP66P20 Protected chassis/IP20 with backplateP21 NEMA 1/IP21 with backplateP55 NEMA 12/IP55 with backplate

[5] RFI FilterH1 Integral class A1 and B1 RFI filterH2 Integral class A2 RFI filterH3H4HX

Integral class A1 and B1 RFI filterIntegral class A1 and B1 RFI filterNone (T6 only)

[6] BrakingX No brake IGBTB

T

Brake IGBT mounted (resistor sold separatelySafe stop terminal

U Safe stop with brake

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains Input (1)

X No option1 Mains disconnect3 Mains disconnect and fuses5 Mains disconnect, fuses and

loadsharing7 Fuses8 Mains disconnect and loadsharingA Fuses and loadsharingD Loadsharing terminals

For Common Options see page 7.

Use the Performance Data Selection charts on pages 8-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

25 - 60 Hp 208 - 240 VAC50 - 125 Hp 380 - 480 VAC60 - 125 Hp 525 - 600 VAC

C Frame Sizes

Page 20: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

20 06/30/11FC200 PL

VLT® AQUA Drive

D1D2D3D4

HP FLA Size

E00 w Graphic LCP Enclosure Options RFI Options

Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 H6

380

- 480

VAC

—T4

150 190.0 P110 D3 $9,313 nc $4,125 D1 $975 $1,585 $1,235 $1,845 nc $1,275 $1,795 200 240.0 P132 D3 $11,611 nc $4,125 D1 $975 $1,585 $1,235 $1,845 nc $1,540 $2,060 250 303.0 P160 D4 $15,030 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $1,885 $2,405 300 361.0 P200 D4 $18,121 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $2,250 $2,770 350 443.0 P250 D4 $20,743 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $2,685 $3,205

HP FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C X 3 5 7 A D150 190.0 P110 nc $840 $445 $1,285

nc

nc $425 nc $800 $1,175 $315 $690 $375 200 240.0 P132 nc $1,010 $540 $1,550 nc $425 nc $800 $1,255 $315 $770 $455 250 303.0 P160 nc $1,240 $660 $1,900 nc $425 nc $1,645 $2,200 $500 $1,055 $555 300 361.0 P200 nc $1,480 $790 $2,270 nc $425 nc $1,645 $2,305 $500 $1,160 $660 350 443.0 P250 nc $1,770 $1,010 $2,780 nc $425 nc $1,645 $2,435 $500 $1,290 $790

KW FLA Size

E0D w Graphic LCP Enclosure Options RFI Options

Frame Base E0D C0D Frame E2D E5D E2M E5M H2 H4 H6

525

- 690

VAC

—T7

45 54.0 P45K D3 $6,172 nc $3,590 D1 $700 $900 $965 $1,165 nc $960 $1,02055 73.0 P55K D3 $7,346 nc $3,590 D1 $700 $900 $965 $1,165 nc $1,055 $1,115 75 86.0 P75K D3 $7,965 nc $3,590 D1 $700 $900 $965 $1,165 nc $1,175 $1,525 90 108.0 P90K D3 $9,122 nc $3,590 D1 $700 $900 $965 $1,165 nc $1,310 $1,700

KW FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C X 3 5 7 A D45 54.0 P45K nc $575 $245 $820

nc

- nc nc $1,300 $1,555 $475 $730 $255 55 73.0 P55K nc $655 $295 $950 - nc nc $1,390 $1,680 $565 $855 $290 75 86.0 P75K nc $750 $335 $1,085 - nc nc $1,835 $2,170 $645 $980 $335 90 108.0 P90K nc $835 $400 $1,235 - nc nc $2,155 $2,530 $965 $1,340 $375

For Common Options see page 7.

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

Use the Performance Data Selection charts on pages 9-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

150 - 350 Hp 380 - 480 VAC45 - 400 kW 525 - 690 VAC

D Frame Sizes

Page 21: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

21 06/30/11FC200 PL

VLT® AQUA Drive

D1D2D3D4

KW FLA Size

E00 w Graphic LCP Enclosure Options RFI Options

Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 H6

525

- 690

VAC

—T7

110 131.0 P110 D3 $9,771 nc $4,125 D1 $975 $1,585 $1,235 $1,845 nc $1,565 $2,085 132 155.0 P132 D3 $11,182 nc $4,125 D1 $975 $1,585 $1,235 $1,845 nc $1,910 $2,430 160 195.0 P160 D3 $12,919 nc $4,125 D1 $975 $1,585 $1,235 $1,845 nc $2,305 $2,830 200 242.0 P200 D4 $15,348 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $2,825 $3,345 250 290.0 P250 D4 $19,560 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $3,375 $3,900 315 344.0 P315 D4 $23,067 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $4,030 $4,550 400 400.0 P400 D4 $27,475 nc $4,950 D2 $1,880 $3,050 $2,355 $3,525 nc $4,455 $4,975

KW FLA SizeBrake Option Display Option Coating Mains Input Option

X B T U G X C X 3 5 7 A D110 131.0 P110 nc $865 $445 $1,310

nc

- nc nc $2,165 $2,565 $315 $715 $400 132 155.0 P132 nc $965 $540 $1,505 - nc nc $2,165 $2,595 $315 $745 $430 160 195.0 P160 nc $1,165 $660 $1,825 - nc nc $2,165 $2,620 $315 $770 $455 200 242.0 P200 nc $1,425 $790 $2,215 - nc nc $2,425 $2,980 $500 $1,055 $555 250 290.0 P250 nc $1,700 $1,010 $2,710 - nc nc $2,425 $3,085 $500 $1,160 $660 315 344.0 P315 nc $2,035 $1,220 $3,255 - nc nc $2,425 $3,215 $500 $1,290 $790 400 400.0 P400 nc $2,240 $1,440 $3,680 - nc nc $2,425 $3,295 $500 $1,370 $870

[1] Performance Level202 AQUA Drive

[2] Power SizeP45K 50 HP (45 kW)P55K 60 HP (55 kW)P75K 75 HP (75 kW)P90K 100 HP (90 kW)P110 150 HP/110 kW (at 460V)

125 HP (at 575V)110 kW (at 690V)

P132 200 HP /132 kW (at 460V)150 HP (at 575V)132 kW (at 690V)

P160 250 HP /160 kW (at 460V)200 HP (at 575V)160 kW (at 690V)

P200 300 HP /200 kW (at 460V)250 HP (at 575V)200 kW (at 690V)

P250 350 HP /200 kW (at 460V)300 HP (at 575V)250 kW (at 690V)

P315 350 HP/315 kWP400 400 HP/400 kW

[3] AC Line VoltageT4 3Ø 380 – 480 VACT7 3Ø 525 - 690 VAC

[4] EnclosureE00 Chassis/IP00C00 Chassis/IP00 stainless steel heatsinkE21 NEMA 1/IP21E2M NEMA 1/IP21 includes main sheildE54 NEMA 12/IP54E5M NEMA 12/IP54 includes main sheild

[5] RFI FilterH2 Integral class A2 RFI filterH4 Integral class A1 and B1 RFI filterH6 Marine Class

[6] BrakingX No brake IGBTB

T

Brake IGBT mounted (resistor sold separatelySafe stop terminal

U Safe stop with brake

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains Input X No option3 Mains disconnect and fuses5 Mains disconnect, fuses and

loadsharing7 FusesA Fuses and loadsharingD Loadsharing terminals

For Common Options see page 7.

Use the Performance Data Selection charts on pages 9-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

150 - 350 Hp 380 - 480 VAC45 - 400 kW 525- 690 VAC

D Frame Sizes

Page 22: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

22 06/30/11FC200 PL

VLT® AQUA Drive

HP FLA Size

E00 w Graphic LCP Enclosure Options RFI Options Brake Option

Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 X B T U R

380

- 480

VAC

—T4

450 540.0 P315 E2 $24,363 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $3,250 nc $2,130 $1,220 $3,350 $950 500 590.0 P355 E2 $28,689 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $3,835 nc $2,515 $1,440 $3,955 $1,120 550 678.0 P400 E2 $34,730 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $4,355 nc $2,845 $1,630 $4,475 $1,270 600 730.0 P450 E2 $37,741 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc $4,995 nc $3,380 $1,935 $5,315 $1,510

HP FLA SizeDisplay Option Coating Mains Input Option

G X C X 3 5 7 A D450 540.0 P315

nc

- nc nc $4,150 $5,100 $810 $1,760 $950 500 590.0 P355 - nc nc $4,150 $5,270 $810 $1,930 $1,120 600 678.0 P400 - nc nc $4,150 $5,420 $810 $2,080 $1,270 650 730.0 P450 - nc nc $4,150 $5,660 $810 $2,320 $1,510

KW FLA Size

E00 w Graphic LCP Enclosure Options RFI Options Brake Option

Frame Base E00 C00 Frame E21 E54 E2M E5M H2 H4 X B T U R

525

- 690

VAC

—T7

450 450.0 P450 E2 $33,576 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - nc $2,130 $1,220 $3,350 $950 500 500.0 P500 E2 $43,013 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - nc $2,515 $1,440 $3,955 $1,120 560 570.0 P560 E2 $53,459 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - nc $2,845 $1,630 $4,475 $1,270 630 630.0 P630 E2 $62,253 nc $9,895 E1 $3,260 $5,295 $3,955 $5,985 nc - nc $3,380 $1,935 $5,315 $1,510

KW FLA SizeDisplay Option Coating Mains Input Option

G X C X 3 5 7 A D450 450.0 P450

nc

- nc nc $4,150 $5,100 $810 $1,760 $950 500 500.0 P500 - nc nc $4,150 $5,270 $810 $1,930 $1,120 560 570.0 P560 - nc nc $4,150 $5,420 $810 $2,080 $1,270 630 630.0 P630 - nc nc $4,150 $5,660 $810 $2,320 $1,510

E1E2

[1] Performance Level202 AQUA Drive

[2] Power SizeP315 450 HP (315 kW)P355 500 HP (355 kW)P400 600 HP (400 kW)P450 650 HP (450 kW) (at 460 v)

450 HP (at 575 V)450 kW (at 690 V)

P500 (500 kW) (at 460 v)P560 (560 kW) (at 460 v)P630 (630 kW) (at 460 v)

[3] AC Line VoltageT4 3Ø 380 – 480 VACT7 3Ø 525 – 690 VAC

[4] EnclosureE00 Chassis/IP00C00 Chassis/IP00 stainless steel heatsinkE21 NEMA 1/IP21E2M NEMA 1/IP21includes main sheildE54 NEMA 12/IP54E5M NEMA 12/IP54 includes main sheild

[5] RFI FilterH2 Integral class A2 RFI filterH4 Integral class A1 and B1 RFI filter

[6] BrakingX No brake IGBTB

T

Brake IGBT mounted (resistor sold separatelySafe stop terminal

UR

Safe stop with brakeRegen Terminals

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains InputX No option3 Mains disconnect and fuses5 Mains disconnect, fuses and

loadsharing7 FusesA Fuses and loadsharingD Loadsharing terminals

Use the Performance Data Selection charts on pages 9-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

For Common Options see page 7.

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17]

FC 202 - - - - - - G - - - X - X - SXXX - X - - - - -

450 - 650 Hp 380 - 480 VAC450 - 630 kW 525- 690 VAC

E Frame Sizes

Page 23: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

This page left blank intentionally.

Page 24: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

24 06/30/11FC200 PL

VLT® AQUA Drive

F1F2F3F4

Contact Factory for complete pricing and ordering instructions

[1] Performance Level202 AQUA Drive

[2] Power Size (2)

P450 650 HPP500 700 HPP560 750 HPP630 900 HP/630 KWP710 1000 HP/710 KWP800 1200 HP/800 KWP900 900 KW (690 VAC Only)P1M0 1000 KW (690 VAC Only)P1M2 1200 KW (690 VAC Only)

[3] AC Line VoltageT4 3Ø 380 - 480 VACT7 3Ø 525 – 690 VAC

[5] RFI filter (2)

H2 Integral Class A2 filterH4 Integral Class A1 & B1 filterHE Integral Class A2 filter with residual

current monitorHF Integral Class A1 & B1 filter with

residual current monitorHG Integral Class A2 filter with

insulation resistance monitorHH Integral Class A1 & B1 filter with

insulation resistance monitorHJ Integral Class A2 filter with NAMUR

terminalsHK Integral Class A1 & B1 filter with

NAMUR terminalsHL Integral Class A2 filter with

residual current monitor & NAMUR terminals

HM Integral Class A1 & B1 filter with residual current monitor & NAMUR terminals

HN Integral Class A2 filter with insulation resistance monitor & NAMUR terminals

HP Integral Class A1 & B1 filter with insulation resistance monitor & NAMUR terminals

L2* Low Harmonic Filter with integral A2 filter (specify E21 or E54 for enclosure option)

L4* Low Harmonic Filter with integral A1 & B1 filter (specify E21 or E54 for enclosure option)

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]

FC 202 - - - - - - - - - X - X - SXXX - X - - - - - -

[4] EnclosureE21 IP21 NEMA 1

L2X IP21 NEMA 1 with cabinet light and IEC 230 VAC power outlet

L2A IP21 NEMA 1 with cabinet light and IEC 115 VAC power outlet

H21 IP21 NEMA 1 with space heater and thermostat

R2X IP21 NEMA 1 with space heater, thermostat, cabinet light and IEC 230 VAC power outlet

R2A IP21 NEMA 1 with space heater, thermostat, cabinet light and IEC 115 VAC power outlet

E54 IP54 NEMA 12LEX IP54 NEMA 12 with cabinet light

and IEC 230 VAC powerL5A IP54 NEMA 12 with cabinet light

and IEC 115 VAC powerH54 IP54 NEMA 12 with space heater

and thermostatR5X IP54 NEMA 12 with space heater,

thermostat, cabinet light and IEC 230 VAC power outlet

R5A IP54 NEMA 12 with space heater, thermostat, cabinet light and IEC 115 VAC power outlet

E5H IP54 NEMA 12 hybrid for low harmonic drive (must specify L2 or L4 for RFI option)

Use the Performance Data Selection charts on pages 9-11 to determine the frame size and enclosure style availability for the selected Power Size [2}.

F Frame Sizes

Page 25: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

25 06/30/11FC200 PL

VLT® AQUA Drive

Contact Factory for complete pricing and ordering instructions

[6] BrakingX NoneB Brake IGBT only (resistor sold

separately)M IEC emergency stop pushbutton

withPilzsafetyrelayN Brake IGBT with IEC emergency

stoppushbuttonwithPilzsafetyrelay

P IEC emergency stop pushbutton with regeneration terminals

R Regeneration terminals only

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains InputX NoneE Mains disconnect switch, contactor

and fusesF Mains circuit breaker, contactor and

fusesG Mains disconnect switch, contactor,

loadsharing terminals and fusesH Mains circuit breaker, contactor,

loadsharing terminals and fusesJ Mains circuit breaker and fusesK Mains circuit breaker, loadsharing

terminals and fuses

[10] Power Terminals and Motor Starters

X NoneE 30 Amp fuse protected power

terminalF 30 Amp fuse protected power

terminal & 2.5-4 Amp manual motor starter

G 30 Amp fuse protected power terminal & 4 – 6.3 Amp manual motor starter

H 30 Amp fuse protected power terminal & 6.3 – 10 Amp manual motor starter

J 30 Amp fuse protected power terminal & 10 – 16 Amp manual motor starter

K Two 2.5 – 4 Amp manual motor starters

L Two 4 – 6.3 Amp manual motor starters

M Two 6.3 – 10 Amp manual moor starters

N Two 10 – 16 Amp manual motor starters

[11] Auxiliary 24 V Supply & External Temperature Monitoring

X NoneH 5 Amp 24 V power supplyG 5 Amp 24 V power supply &

External Temperature MonitoringJ External Temperature Monitoring

[12] Language PackageX Standard Package

[18] Control Power D Option CardDX NoneD0 24 VDC input MCB107 option card

[13] FieldbusAX No fieldbusA0 Profibus MCA101A4 DeviceNet MCA104

AN Ethernet IP MCA121

AQ Modbus TCP/IP MCA 122AL Profinet

[14] Application OptionB4 PTC Sensor Input MCB 114BO Analog IO + battery backup

MCB109BX No application optionBK General purpose I/O

MCB101BY Extended cascade controlBP Relay expansion MCB105

[15] Motion ControlCX No motion control option

[16] Advanced Cascade Control

X No cascade control optionS Advanced cascade

[17] Voltage InputDX No DC inputD0 24 VDC option MCB107

Page 26: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

26 06/30/11FC200 PL

VLT® AQUA Drive

[2] POWER SIZEP160 250 HP/160 kWP200 300 HP/200 kWP250 350 HP/250 kWP315 450 HP/315 kWP355 500 HP/355 kWP400 550 HP/400 kWP450 650 HP/450 kW

[3] AC LINE VOLTAGET4 3 Ø 380-480 VAC

[4] ENCLOSURE TYPEE21 NEMA 1/ IP21E54 NEMA 12/ IP54

[5] RFI FilterL2 Low harmonic filter with integral A2

filter.L4 Low harmonic filter with integral A1 &

B1 filter.

[6] Brake/Safe Stop OptionsX NoneB Brake igbt installed (resistor sold

separately)R Regen terminals (e frame drives only)T Safe stop terminalU Brake IGBT with safe stop terminal

(FC202 only)

[1] [2] [3] [4] [5] [6] [7] [8] [9] [10] [11] [12] [13] [14] [15] [16] [17] [18]

FC 202 - - T4 - E21 - - X - G - C - - X - X - SXXX - X - AX - BX - CX - X - XX - DX

VLT® Low Harmonic Drives

Common Options on pages 7.Low Harmonic Drives

New Danfoss low harmonic drives continuously regulate the network and load conditions without affecting the connected motor. Low harmonic drives are available for theD,EandFframesizedrivescoveringthepower range of 200 – 900 HP (132 – 630 kW) with160%torqueoverloador250–1000HP(160–710kWwith110%torqueoverload.The low harmonic drives are offered in a NEMA 1/IP21 or Nema 12/IP54 rated enclosure.

Low harmonic drives are available for 380-480 VAC (T4) input only. Two low harmonic versions are available:

L2 With integral A2 Filter

L4 With Integral A1 & B1 Filter

[7] HMI OptionG Graphical LCP included on all models

[8] Conformal CoatingFC202 PCB’s are always coated - the degree ofprotection is as described belowX Standard 3C2 Conformal CoatingC Upgraded 3C3 Conformal Coating

[9] Mains Input OptionsX No option installed3 Mains disconnect switch & fuses5 Mains disconnect switch, fuse and

loadshare terminals7 Fuses onlyA Fuses with loadshare terminalsD Loadshare terminals only

T4

w Graphic LCP Enclosure Options LHD Option Coating Mains Input OptionFrame HP FLA Size Base E21 E54 L2 L4 X C X 3 7

D11

250 303 P160 $15,030  $    1,880  $    4,895  $ 20,070  $ 22,838 nc $425 nc $1,645  $   500

300 361 P200 $18,121  $    1,880  $    4,895  $ 21,260  $ 25,410 nc $425 nc $1,645  $   500

350 443 P250 $20,743  $    1,880  $    4,895  $ 23,725  $ 29,095 nc $425 nc $1,645  $   500

E7

450 540 P315 $24,363  $    3,260  $    9,360  $ 27,815  $ 34,310 - nc nc $4,150  $   810

500 590 P355 $28,689  $    3,260  $    9,360  $ 30,395  $ 38,060 - nc nc $4,150  $   810

600 678 P400 $34,730  $    3,260  $    9,360  $ 31,580  $ 40,285 - nc nc $4,150  $   810

650 730 P450 $37,741  $    3,260  $    9,360  $ 36,720  $ 46,710 - nc nc $4,150  $   810

Page 27: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

27 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

Motion Controller Option

Fieldbus Option

Application Option

DC Input Option

MCB 107 24V DC supply input option card 130B1108

Pluggable, field installable option cards allow the VLT® AQUA Drives capabilities to be easily expanded.

MCA 101 Profibus option card 130B1100

MCB 101 general purpose I/O option card 130B1125

MCB 105 Relay option card 130B1110

Fieldbus Options & AccessoriesUncoated Coated Product Type Description List Price130B1100 130B1200 MCA101 VLT® PROFIBUS DP V1 MCA 101 $250.00 130B1102 130B1202 MCA104 VLT® DeviceNet MCA 104 $190.00 130B1135 130B1235 MCA120 VLT® ProfiNet MCA 120 $500.00 130B1119 130B1219 MCA121 VLT® EtherNet IP MCA 121 $510.00 130B1196 130B1296 MCA122 VLT® Modbus TCP/IP MCA 122 $500.00 130B1112 MCF104 Profibus Adapter Sub-D9 Connector $115.00 175N2584 ethernet master/f. ethernet/ip/modbus t $1,205.00

Application Option CardsUncoated Coated Product Type Description List Price130B1125 130B1225 MCB101 VLT® General Purpose I/O MCB 101 $160.00 130B1110 130B1210 MCB105 VLT® Relay Option MCB 105 $175.00 130B1108 130B1208 MCB107 VLT® 24 V DC Supply Option MCB 107 $105.00 130B1172 130B1272 MCB114 VLT® PTC Sensor Input Card MCB 114 $245.00 130B1118 130B1218 MCO101 VLT® Extended Cascade Controller MCO101 $1100.00

Motion Control Options & AccessoriesUncoated Coated Product Type Description List Price130B1154 130B1254 MCO102 VLT® Advanced Cascade Controller MCO102 $1695.00

Page 28: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

28 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

HMI (faceplate) options from left to right:• Graphic130B1124• Numeric130B1107• Blank(mustbeconfiguredwithdrive)

Remote mounting kit 130B1117 6-pole, spring-loaded connector 130B1071

Local Control Panels & AccessoriesPart # Product Type Description List Price130B1124 LCP101 LCP 101 Numerical Local Control Panel $170.00 130B1107 LCP102 LCP 102 Graphical Local Control Panel $170.00 130B1113 MCF102 LCP Panel Mounting Kit, incl. graph. LCP $255.00 130B1114 MCF102 LCP Panel Mounting Kit, incl. numeric LCP $255.00 130B1117 MCF102 LCP Panel Mounting Kit, All LCPs $90.00 175Z0929 option,remote lcp cable,3m $40.00 130B1155 MCF103 USB extension, 350 mm cable $45.00 130B1156 MCF103 USB extension, 650 mm cable $50.00

AccessoriesPart # Product Type Description List Price130B1116 screw terminals/screw terminal kit $25.00 130B1064 Terminal Block for DC Link connection on A2/A3 Frames $105.00 130B1021 Accessory Bag for A1 Frame $70.40 130B1022 Accessory Bag for A5 Frame $30.00 130B1023 Accessory Bag for A2/A3 Frame $30.00 130B0633 Accessory Bag for A1-A5 Frame (brake & load share connector) $30.00 130B2060 Accessory Bag for B1 Frame $30.00 130B2061 Accessory Bag for B2 Frame $30.00 130B0980 Accessory Bag for B3 Frame $32.80 130B1300 Accessory Bag for B4 Frame (18.5-22 KW) $53.40 130B1301 Accessory Bag for B4 Frame (30 KW) $60.20 130B0046 Accessory Bag for C1 Frame $46.20 130B0047 Accessory Bag for C2 Frame $48.90 130B0981 Accessory Bag for C3 Frame $52.80130B0982 Accessory Bag for C4 Frame (55 KW) $53.40130B0983 Accessory Bag for C4 Frame (75 KW) $52.70

Page 29: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

29 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

High Power Option KitsPart # Product Type Description List Price

176F4600 kit,3r,rittal,d3 $1,355.00 176F4601 kit,3r,rittal,d4 $1,475.00 176F1852 kit,3r,rittal,e2 $4,000.00 176F0296 kit,3r,industrial enclosure,d3 $1,135.00 176F0295 kit,3r,industrial enclosure,d4 $945.00 176F0298 kit,3r,industrial enclosure,e2 $2,930.00 176F1827 kit, pedestal, d1 d2 $1,240.00 176F1824 kit,cooling duct,1800 mm rittal,d3 $895.00 176F1823 kit,cooling duct,1800 mm rittal,d4 $895.00 176F1826 kit,cooling duct,2000 mm rittal,d3 $970.00 176F1825 kit,cooling duct,2000 mm rittal,d4 $970.00 176F1850 kit,cooling duct,2000 mm rittal,e2 $1,810.00 176F0299 kit,cooling duct,2200 mm rittal,e2 $2,550.00 176F1775 kit, duct, top only, d3/d4 $250.00 176F1776 kit, duct, top only, e2 $510.00 176F1862 kit,top and bottom covers,d3,d4 $135.00 176F1861 kit, top and bottom covers, e2 $875.00 176F1781 kit, ip20 conversion, d3/d4 $225.00 176F1781 kit, ip20 conversion, d3/d4 $225.00 176F1782 kit, ip20 conversion, d3/d4 $225.00 176F1783 kit, ip20 conversion, d3/d4 $225.00 176F1774 kit,motor cable clamp brktip00,d3 $75.00 176F1746 kit,motor cable clamp brkt,ip00,d4 $85.00 176F1745 kit,motor cable clamp brkt,ip00,e2 $210.00 176F1779 kit, ip20 conversion, d3/d4 $225.00 176F0799 kit,mains shield,d1 d2 $375.00 176F1851 kit,mains shield,e1 $995.00 176F8456 kit,loadshare,d1 d3 $420.00 176F8455 kit,loadshare,d2 d4 $540.00 176F1742 kit,fc profibus sub-d9, d and e $220.00

Steel BackplatesPart # Type Description List Price

130B3150 MCF108 backplate A4 $30.00130B1098 MCF108 back plate A5 $30.00 130B3383 MCF108 backplate B1 $30.00 130B3397 MCF108 backplate B2 $40.00 130B3910 MCF108 back plate C1 $40.00 130B3911 MCF108 back plate C2 $50.00

Stainless Steel Backplates (Type 304)Part # Type Description List Price

130B3158 MCF108 backplate A4/IP66 $90.00130B3242 MCF108 backplate, A5 IP66 $95.00 130B3434 MCF108 backplate/ B1, IP66 $100.00 130B3465 MCF108 backplate B2, IP66 $105.00 130B3468 MCF108 backplate C1, IP66 $155.00 130B3491 MCF108 back plate C2, IP66 $225.00

Weather ShieldPart # Description List Price

130B4598 A4 - B2 Frames $425.00130B4597 C1 - C2 Frames $495.00

251.800.621.8806 www.danfossdrives.com

Accessories List Price

Ordering Number Product Type Description List Price

Backplates130B1098 MFC 108 For A5 frames, IP55/NEMA 12 30130B3383 MFC 108 For B1 frames, IP21/IP55 30130B3397 MFC 108 For B2 frames, IP21/IP55 40130B3910 MFC 108 For C1 frames, IP21/IP55 40130B3911 MFC 108 For C2 frames, IP21/IP55 50

Backplates / Stainless Steel (Type 304)130B3242 MFC 108 For A5 frames, IP66/NEMA 4X 95130B3434 MFC 108 For B1 frames, IP66/NEMA 4X 100130B3465 MFC 108 For B2 frames, IP66/NEMA 4X 105130B3468 MFC 108 For C1 frames, IP66/NEMA 4X 155130B3491 MFC 108 For C2 frames, IP66/NEMA 4X 225

Backplate

VLT® AQUA Drive Accessories

Ordering Number List Price Fits VLT AQUA Drive Frame:

Through-Panel Mounting Kit Dimensions (in)Height Width Depth

130B1028 $85 A5 20.1 13.1 4.7130B1046 95 B1 22.4 13.1 5.9130B1047 115 B2 29.1 13.1 5.9130B1048 150 C1 30.6 15.2 6.3130B1049 185 C2 33.7 17.6 6.3

Through-Panel Mounting Kits

The drive can be mounted with the heatsink exposed in a duct with a cooling airstream provided by external fans either dedicated for the purpose or as part of a process close to the drive. If this confi guration is used, the drive’s built-in fan can be removed.

Allows the drive to be mounted through the back of a panel wall so that cooling air can remove the heat without the risk of damaging electronics with dust, heat, moisture, or corrosive elements. For use with IP21 and IP55 units with the front cover removed.

If the drive is not mounting into a duct with an existing airfl ow, adding a backplate (purchased separately) creates a duct through which the drive’s built-in fan can force cooling air over the heatsink.

130B4597

130B4598

Page 30: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

30 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

Through-Panel Mounting Kits

IP21 Option Kits for IP20 A, B and C Frames

The drive can be mounted with the heatsink exposed in a duct with a cooling airstream provided by external fans either dedicated for the purpose or as part of a process close to the drive. If this configuration is used, the drive’s built-in fan can be removed.

Allows the drive to be mounted through the back of a panel wall so that cooling air can remove the heat without the risk of damaging electronics with dust, heat, moisture, or corrosive elements. For use with IP21 and IP55 units with the front cover removed.

If the drive is not mounting into a duct with an existing airflow, adding a backplate (purchased separately) creates a duct through which the drive’s built-in fan can force cooling air over the heatsink.

A Frames

B and C Frames

Through Panel Mounting Kits

Fits Frame Height Width DepthPart

Number List PriceA5 20.1 13.1 4.7 130B1028 $90.00 B1 22.4 13.1 5.9 130B1046 $105.00 B2 29.1 13.1 5.9 130B1047 $120.00 C1 30.6 15.2 6.3 130B1048 $150.00 C2 33.7 17.6 6.3 130B1049 $185.00

Fits FrameHP Range (High Overload)

Height Width DepthPart

Number List Price230V 460V 600V

A2 1/3 to 3 1/2 to 5 - 14.6 3.5 8.1 130B1112 $130.00 130B1132* $145.00

A3 4 to 5 7-1/2 to 10 1 to 10 14.6 5.1 8.1 130B1123 $155.00 130B1133* $145.00

B3 7-1/2 to 10 15 to 20 15 to 20 20.6 6.5 9.8 130B1187 $175.00 B4 15 25 to 30 25 to 30 28.6 9.1 9.8 130B1189 $280.00 C3 20 to 25 40 to 60 40 to 50 31.1 12.1 13.1 130B1191 $455.00 C4 30 to 50 75 to 100 60 to 100 39.7 14.6 13.1 130B1193 $620.00

* Top Only subtract 3.1 from height.

Page 31: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

31 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

Sine-Wave Filters

IP00 3x240-500 VAC Output Current Rating Dimensions ( in ) Filter Loss

(w) List Price @50Hz @60Hz @100Hz Height Width Depth 130B2404 MCC101A2K5T3E00A 2.5 2.5 2 7.13 2.95 8.07 60 $300 130B2406 MCC101A4K5T3E00A 4.5 4 3.5 7.13 2.95 8.07 65 $340 130B2408 MCC101A8K0T3E00A 8 7.5 5.5 9.69 3.54 8.07 80 $395 130B2409 MCC101A10KT3E00A 10 9.5 7.5 9.69 3.54 8.07 90 $460 130B2411 MCC101A17KT3E00A 17 16 13 9.69 5.12 8.07 115 $510 130B2412 MCC101A24KT3E00A 24 23 18 10.24 5.91 10.24 150 $790 130B2413 MCC101A38KT3E00A 38 36 28.5 14.96 5.91 10.24 160 $1,040 130B2281 MCC101A48KT3E00A 48 45.5 36 18.11 6.69 10.24 260 $1,560 130B2282 MCC101A62KT3E00A 62 59 46.5 21.26 6.69 10.24 280 $1,950 130B2283 MCC101A75KT3E00A 75 71 56 21.26 6.69 10.24 330 $2,350 130B3179 MCC101A115T3E00B 115 109 86 20.47 18.50 13.15 470 $3,200 130B3182 MCC101A180T3E00B 180 170 135 22.83 18.50 12.24 650 $4,650 130B3184 MCC101A260T3E00B 260 246 195 20.47 19.69 15.75 850 $5,600 130B3186 MCC101A410T3E00B 410 390 308 20.47 19.69 19.29 1150 $8,300 130B3188 MCC101A510T3E00B 510 456 360 20.47 19.69 19.29 1450 $9,995 130B3191 MCC101A660T3E00B 660 627 495 24.41 24.41 22.95 2000 $12,900 130B3193 MCC101A800T3E00B 800 712 562 24.41 24.41 22.95 3000 $15,700

IP20 / 23 3x240-500 VAC Output Current Rating Dimensions ( in ) Filter Loss

(w) List Price @50Hz @60Hz @100Hz Height Width Depth 130B2439 MCC101A2K5T3E20A 2.5 2.5 2 7.13 2.95 8.07 60 $360 130B2441 MCC101A4K5T3E20A 4.5 4 3.5 7.13 2.95 8.07 65 $415 130B2443 MCC101A8K0T3E20A 8 7.5 5.5 9.69 3.54 8.07 80 $480 130B2444 MCC101A10KT3E20A 10 9.5 7.5 9.69 3.54 8.07 90 $560 130B2446 MCC101A17KT3E20A 17 16 13 9.69 5.12 8.07 115 $615 130B2447 MCC101A24KT3E20A 24 23 18 10.24 5.91 10.24 150 $950 130B2448 MCC101A38KT3E20A 38 36 28.5 14.96 5.91 10.24 160 $1,330 130B2307 MCC101A48KT3E20A 48 45.5 36 18.11 6.69 10.24 260 $2,350 130B2308 MCC101A62KT3E20A 62 59 46.5 21.26 6.69 10.24 280 $2,750 130B2309 MCC101A75KT3E20A 75 71 56 21.26 6.69 10.24 330 $3,200 130B3181 MCC101A115T3E23B 115 109 86 36.14 35.59 29.76 470 $4,300 130B3183 MCC101A180T3E23B 180 171 135 36.14 35.59 29.76 650 $6,250 130B3185 MCC101A260T3E23B 260 247 195 36.14 35.59 29.76 850 $7,500 130B3187 MCC101A410T3E23B 410 390 308 36.14 35.59 29.76 1150 $10,050 130B3189 MCC101A510T3E23B 510 456 360 45.71 48.19 37.60 1450 $12,200 130B3192 MCC101A660T3E23B 660 627 495 45.71 48.19 37.60 2000 $15,700 130B3194 MCC101A800T3E23B 800 712 562 45.71 48.19 37.60 3000 $18,995

IP00 3x525-690 VACOutput Current Rating Dimensions ( in ) Filter Loss

(w) List Price @50Hz @60Hz @100Hz Height Width Depth 130B3195 MCC101A13KT7E00B 13 12 9 18.31 4.53 8.86 115 $1,625 130B4112 MCC101A28KT7E00B 28 26 21 19.88 6.10 10.63 150 $2,995 130B4114 MCC101A45KT7E00B 45 42 33 24.61 6.10 14.57 250 $4,395 130B4116 MCC101A76KT7E00B 76 72 57 20.47 18.50 13.07 475 $6,295 130B4118 MCC101A115T7E00B 115 109 86 20.47 18.50 13.39 750 $7,795 130B4121 MCC101A165T7E00B 165 156 124 18.50 19.69 15.75 1100 $9,595 130B4125 MCC101A260T7E00B 260 246 195 21.06 24.41 18.11 1300 $12,250 130B4129 MCC101A360T7E00B 360 314 270 25.98 31.50 24.02 1800 $15,995 130B4152 MCC101A430T7E00B 430 407 323 25.98 31.50 24.02 2150 $19,250 130B4154 MCC101A530T7E00B 530 502 398 25.98 31.50 26.93 2400 $20,995 130B4156 MCC101A660T7E00B 660 625 496 27.17 31.50 28.07 3000 $22,995

IP20/23 3x525-690 VACOutput Current Rating Dimensions ( in ) Filter Loss

(w) List Price @50Hz @60Hz @100Hz Height Width Depth 130B3196 MCC101A13KT7E20B 13 12 9 18.31 4.65 9.57 115 $1,950 130B4113 MCC101A28KT7E20B 28 26 21 19.88 6.22 12.20 150 $3,595 130B4115 MCC101A45KT7E20B 45 42 33 24.61 6.22 12.20 250 $5,275 130B4117 MCC101A76KT7E23B 76 72 57 28.15 29.92 24.41 475 $7,500 130B4119 MCC101A115T7E23B 115 109 86 28.15 29.92 24.41 750 $9,250 130B4124 MCC101A165T7E23B 165 156 124 36.14 35.59 31.18 1100 $11,500 130B4126 MCC101A260T7E23B 260 246 195 45.71 48.19 39.02 1300 $14,395 130B4151 MCC101A360T7E23B 360 314 270 45.71 48.19 39.02 1800 $18,995 130B4153 MCC101A430T7E23B 430 407 323 45.71 48.19 39.02 2150 $22,985 130B4155 MCC101A530T7E23B 530 502 398 45.71 48.19 39.02 2400 $24,985 130B4157 MCC101A660T7E23B 660 625 496 45.71 48.19 39.02 3000 $27,885

Page 32: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

32 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

Accessories List Price 130B3137 l-shape terminal kit 1 - 2 holes 10,5mm $75 130B3138 l-shape terminal kit 2 - 4 holes 13 mm $165 130B4178 cable glands floor mounted ip23 filters $100 130B4175 terminal kit for 40a for du/dt filter $25 130B4176 terminal kit 80/105a for du/dt filter $40 130B4177 terminal kit 160a for du/dt filter $45 130B4178 cable glands floor mounted ip23 filters $100

Protective earth (PE) grounding Plate for IP00 and IP20 wall mounted filters. The accessory bag also includes all necessary screws and cable holders.

Wall mounted Sine-wave filterIP00 IP20 Accessory Bag List Price

130B2404 130B2439

130B0385 $40 130B2406 130B2441 130B2408 130B2443 130B2409 130B2444 130B2411 130B2446 130B2412 130B2447

130B0386 $45 130B2413 130B2448 130B2341 130B2321 130B2281 130B2307

130B0387 $85 130B2282 130B2308 130B2283 130B2309 130B2835 130B2836 130B4175 $60 130B2838 130B2839 130B4176 $60 130B2841 130B2842 130B4127 $60

Accessories L- Shaped Voltage Current Enclosure Danfoss No. L-shape List Price

380 - 500V

115 00 130B3179 N/A

- 23 130B3181 N/A

180 00 130B3182 N/A 23 130B3183 N/A

260 00 130B3184 130B3137 $110 23 130B3185

410 00 130B3186

130B3138 $245 23 130B3187

510 00 130B3188 23 130B3189

660 00 130B3191

130B3139

$490

23 130B3192

800 00 130B3193 23 130B3194

525 - 690V

13 00 130B3195

N/A

20 130B3196

28 00 130B4112 20 130B4113

45 00 130B4114 20 130B4115

76 00 130B4116 23 130B4117

115 00 130B4118 23 130B4119

165 00 130B4121

130B3137 $110 23 130B4124

260 00 130B4125 23 130B4126

360 00 130B4129

130B3138 $245

23 130B4151

430 00 130B4152 23 130B4153

530 00 130B4154 23 130B4155

660 00 130B4156 130B3139 $490 23 130B4157

Cable Glands for Floor Standing Filters Nom. filter current rating

(200-380/460/600/690V) [A] Filter Code

Number Spare

part no. List Price315/303/242/192 130B2848

130B4178 $160480/443/344/290 130B2848658/590/500/450 130B2848880/780/630/630 130B2848

Nom. filter current rating (200-380/460/600/690V) [A]

Filter Code Number

Accessory Bag List Price

44/40/32/27 130B2835 130B4175 $40 130B2836

90/80/58/54 130B2838 130B4176 $60 130B2839

106/105/94/86 130B2841 130B4176 $60 130B2842

177/160/131/108 130B2844 130B4127 $135 130B2845

Voltage Current IP Danfoss No. L-shape List Price

380 - 500V

115 00 130B3179

130B4178 $160

23 130B3181

180 00 130B3182 23 130B3183

260 00 130B3184 23 130B3185

410 00 130B3186 23 130B3187

510 00 130B3188 23 130B3189

660 00 130B3191 23 130B3192

800 00 130B3193 23 130B3194

525 - 690V

13 00 130B3195

130B4175 $40

20 130B3196

28 00 130B4112 20 130B4113

45 00 130B4114 20 130B4115

76 00 130B4116

130B4178 $160

23 130B4117

115 00 130B4118 23 130B4119

165 00 130B4121 23 130B4124

260 00 130B4125 23 130B4126

360 00 130B4129 23 130B4151

430 00 130B4152 23 130B4153

530 00 130B4154 23 130B4155

660 00 130B4156 23 130B4157

Page 33: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

33 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

dV/dt Filters

IP00 Filter

Current rating (Amp)

Filter Losses (W)

Dimensions (in)

List Price

460/480V @ 60Hz 575/600V @

60Hz H W D130B2835 MCC102A40KTME00B 40 32 37 11.61 4.52 6.69 $550 130B2838 MCC102A80KTME00B 80 58 130 15.15 6.1 8.66 $975 130B2841 MCC102A105TME00B 105 94 145 15.55 6.1 8.66 $1,375 130B2844 MCC102A160TME00B 160 131 205 17.51 7.28 9.25 $1,800 130B2847 MCC102A303TME00B 303 242 315 9.25 11.81 7.48 $2,125 130B2849 MCC102A460TME00B 443 344 398 9.25 11.81 9.84 $2,750 130B2851 MCC102A645TME00B 590 500 550 10.62 13.77 9.84 $3,375 130B2853 MCC102A800TME00B 780 660 850 11.14 15.74 11.41 $5,275

IP20/23 Filter

Current rating (Amp)

Filter Losses (W)

Dimensions (in)

List Price

“460/480V @ 60Hz 575/600V @

60Hz H W D130B2836 MCC102A40KTME20B 40 32 37 14.56 4.64 9.52 $655 130B2839 MCC102A80KTME20B 80 58 130 18.7 6.18 8.66 $1,175 130B2842 MCC102A105TME20B 105 94 145 18.7 6.22 8.66 $1,525 130B2845 MCC102A160TME20B 160 131 205 20.66 7.4 9.25 $2,325 130B2848 MCC102A303TME23B 303 242 315 16.73 27.55 7.48 $2,975 130B2850 MCC102A460TME23B 443 344 398 16.73 27.55 9.84 $3,475 130B2852 MCC102A645TME23B 590 500 550 16.73 27.55 9.84 $4,225 130B2854 MCC102A800TME23B 780 660 850 31.18 37 11.41 $8,450

Page 34: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

34 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

AHF Advanced Harmonic Filters

AHF005 AHF010 Enclosure

Rating

Current Rating

Motor Power

VLT Power and Current Ratings

Losses Acoustic noise Frame size List PricesAHF005 AHF010

A Hp FC Rating A W W dBA AHF005 AHF010 AHF005 AHF010 130B1787 130B1770 IP00 10 5 PK37-P4K0 1-7.4 131 93 <70 X1 X1 $2,239 $1,735 130B1752 130B1482 IP20 $2,535 $2,265 130B1788 130B1771 IP00 14 10 P5K5-P7K5 9.9 - 13 184 188 <70 X1 X1 $2,704 $1,859 130B1753 130B1483 IP20 $3,021 $2,365 130B1789 130B1772 IP00 19 15 P11K 19 258 206 <70 X2 X2 $2,894 $2,135 130B1754 130B1484 IP20 $3,400 $2,475 130B1790 130B1773 IP00 25 20 P15K 25 298 224 <70 X2 X2 $3,200 $2,495 130B1755 130B1485 IP20 $3,718 $2,720 130B1791 130B1774 IP00 31 25 P18K 31 335 233 <72 X3 X3 $3,549 $2,840 130B1756 130B1486 IP20 $4,110 $3,010 130B1792 130B1775 IP00 36 30 P22K 36 396 242 <72 X3 X3 $3,920 $3,340 130B1757 130B1487 IP20 $4,530 $3,490 130B1793 130B1776 IP00 48 40 P30K 47 482 374 <72 X3 X3 $4,540 $3,887 130B1758 130B1488 IP20 $5,120 $4,120 130B1794 130B1777 IP00 60 50 P37K 59 574 352 <72 X4 X4 $5,320 $4,510 130B1759 130B1491 IP20 $5,703 $4,800 130B1795 130B1778 IP00 73 60 P45K 73 688 374 <72 X4 X4 $6,170 $5,133 130B1760 130B1492 IP20 $6,590 $5,480 130B1796 130B1779 IP00 95 75 P55K 95 747 428 <75 X5 X5 $7,245 $5,910 130B1761 130B1793 IP20 $7,689 $6,260 130B1797 130B1780 IP00 118 100 P75K 118 841 488 <75 X5 X5 $8,618 $6,770 130B1762 130B1494 IP20 $9,062 $7,280 130B1798 130B1781 IP00 154 125 P90K 154 962 692 <75 X6 X6 $10,100 $7,720 130B1763 130B1495 IP20 $10,320 $8,250 130B1799 130B1782 IP00 183 150 P110 183 1080 743 <75 X6 X6 $11,750 $8,830 130B1764 130B1496 IP20 $12,000 $9,440 130B1900 130B1783 IP00 231 200 P132 231 1194 864 <75 X7 X7 $13,470 $10,110 130B1765 130B1497 IP20 $13,820 $10,680 130B2200 130B1784 IP00 291 250 P160 291 1288 905 <75 X7 X7 $15,059 $11,385 130B1766 130B1498 IP20 $15,800 $12,103 130B2257 130B1785 IP00 355 300 P200 348 1406 952 <75 X7 X7 $16,960 $12,716 130B1768 130B1499 IP20 $17,570 $13,455 130B3168 130B3166 IP00 380 376 1510 1175 <75 X8 X7 $18,590 $14,000 130B3167 130B3165 IP20 $19,220 $14,850 130B2259 130B1786 IP00 436 350 P250 436 1852 1542 <77 X8 X7 $20,200 $15,377 130B1769 130B1751 IP20 $20,640 $16,117

Nema 1 Kit Option

EnclosurePart

NumberNema 1 Enclosure AHF Dimensions List

Pricea b c d eX1 130B3274 4.72 6.30 12.97 13.56 8.48 $475 X2 130B3275 7.48 7.09 17.07 17.66 10.14 $495 X3 130B3276 5.71 8.27 21.40 21.99 9.92 $650 X4 130B3277 9.06 9.06 22.58 21.99 13.50 $795 X5 130B3278 9.06 9.84 26.83 27.42 13.50 $895 X6 130B3279 11.81 10.63 26.83 27.42 16.14 $1,150 X7 130B3281 11.81 12.60 31.36 31.95 18.05 $1,475 X8 130B3282 15.75 13.78 31.36 31.95 21.77 $1,975

Chassis Dimensions

EnclosureDimensions

H W DX1 13.07 7.48 8.11X2 17.72 9.13 9.76X3 23.39 14.88 9.53X4 24.57 14.88 13.11X5 29.09 16.46 13.11X6 30.63 16.46 23.46X7 35.79 18.43 17.68X8 35.87 18.43 21.38

Backplate Option

EnclosurePart

Number List PriceX1 130B3283 $70 X2 130B3284 $85 X3 130B3285 $115 X4 130B3286 $155 X5 130B3287 $199 X6 130B3287 $375 X7 130B3288 $375 X8 130B3288 $375

Page 35: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

35 06/30/11O/A PL

VLT® AQUA Drive Options and Accessories

MCT 10 software offers advanced programming functionality for all Danfoss drive products, greatly reducing programming and setup time. Download from: http://www.danfoss.com/North_America/BusinessAreas/DrivesSolutions

Drives are managed in a standard folder-based user interface that’s familiar and easy to understand. Parameter settings for each drive are contained in a single file, allowing easy duplication of parameter sets between drives.

PC Software

Ordering Number Product Type Description List Price130B1000 MCT 10 MCT 10 set-up software (advanced version) $275

MCT 10 ComparisonMCT 10 Basic MCT 10 Advanced

Number of projects Unlimited UnlimitedNumber of drives per project 4 UnlimitedLogging and scope functions 2 channels 8 channelsReal time logging from drive N/A 4 channelsAlarm display View alarm history Alarm history in saved projectsMotor database N/A Yes

PC Software VLT Misc Accessories

Project folders can also store user-defined files such as PDFs, CAD drawings, or Word documents. MCT 10 is the one PC tool for all your drive programming tasks.

MCT 10 Basic (available free of charge from the Danfoss web site) allows access to a finite number of drives with limited functionality. The Advanced edition, offering a higher level of functionality, is available from your Danfoss sales partner.

Additional Accessories for Drives

Common Mode Filters (Contains 2 per package)

VLT Frame Size Core dimension [in] Weight

(kg)Packaging

Dimensions (in) Part Number List PriceW w H h d A and B 2.36 1.69 1.57 0.98 0.87 0.25 5.12 x 3.94 x 2.76 130B3257 $110

C 4.02 2.72 2.40 1.10 1.46 1.6 7.48 x 3.94 x 2.76 130B3258 $460 D 7.44 5.63 4.96 3.15 1.46 2.45 9.25 x 7.48 x 5.51 130B3259 $1,125

E and F 12.01 9.80 5.79 3.74 1.46 4.55 11.42 x 10.24 x 4.33 130B3260 $1,825

Cable Length ft (m)

A-and B Frame C frame D frame E-F frame T5 T7 T5 T7 T5 T7 T5 T7

165ft (50) 2 4 2 2 2 4 2 2330ft (100) 4 4 2 4 4 4 2 4495ft (150) 4 6 4 4 4 4 4 4985 ft (300) 4 6 4 4 4 6 4 4

Part # Type Description List Price130B1000 MCT-10 opt,vlt software,mct 10 set-up $275.00 130B1001 MCT-10 mct 10 set-up/pc software 5 licences $1,105.00 130B1002 MCT-10 mct 10 set-up/pc software 10 licences $2,205.00 130B1003 MCT-10 mct 10 set-up/pc software 25 licences $5,080.00 130B1004 MCT-10 mct 10 set-up/pc software 50 licences $9,385.00 130B1005 MCT-10 mct 10 set-up/pc software 100 licences $16,940.00 130B1006 MCT-10 mct 10 set-up/pc software >100 licences $22,115.00

Part # Description List Price175Z0967 opt,vlt dialog 5/6000/2800,comm,v 3.0 $45.00 175Z0850 option,remote lcp kit,ip20,n1 $90.00 175N0160 opt,lcp remote kit,fcm 300 series $65.00 175N0131 lcp control unit,vlt2800 $215.00 175N0162 opt,lcp cable fcm 300 $70.00 175N0128 opt,fcm,motor remote $155.00 175Z0929 option,remote lcp cable,3m $39.00 195N3113 accessory,cable,devicenet,5 pole conn $65.00

Page 36: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

36 06/30/11MCD PL

MCD 200 Soft Starter

MCD 201 with Integral BypassHP Rating* Current Rating (A)**

Catalog Number Enclosure 208V 230V 480V 575V Normal Heavy Ordering Number PriceMCD 201-007-T6-CV3 IP 20 5 5 10 15 18 17 175G5187 $585MCD 201-015-T6-CV3 IP 20 7½/10 7½/10 25 30 34 30 175G5188 695 MCD 201-018-T6-CV3 IP 20 – – 30 40 42 36 175G5189 730MCD 201-022-T6-CV3 IP 20 15 15 – 40 48 40 175G5190 835MCD 201-030-T6-CV3 IP 20 20 20 40 50 60 49 175G5191 920MCD 201-037-T6-CV3 IP 20 25 25 50 60 75 65 175G5192 975MCD 201-045-T6-CV3 IP 20 – 30 60 75 85 73 175G5193 1,165 MCD 201-055-T6-CV3 IP 20 30 40 75 100 100 96 175G5194 1,330MCD 201-075-T6-CV3 IP 00 40/50 50 100 125 140 120 175G5195 1,610MCD 201-090-T6-CV3 IP 00 60 60 125 150 170 142 175G5196 2,050MCD 201-110-T6-CV3 IP 00 – 75 150 200 200 165 175G5197 2,299

MCD 202 with Integral Bypass and Motor ProtectionHP Rating* Current Rating (A)**

Catalog Number Enclosure 208V 230V 480V 575V Normal Heavy Ordering Number PriceMCD 202-007-T6-CV3 IP 20 5 5 10 15 18 17 175G5231 $765MCD 202-015-T6-CV3 IP 20 7½/10 7½/10 25 30 34 30 175G5232 900MCD 202-018-T6-CV3 IP 20 – – 30 40 42 36 175G5233 935MCD 202-022-T6-CV3 IP 20 15 15 – 40 48 40 175G5234 1,095MCD 202-030-T6-CV3 IP 20 20 20 40 50 60 49 175G5235 1,195MCD 202-037-T6-CV3 IP 20 25 25 50 60 75 65 175G5236 1,240MCD 202-045-T6-CV3 IP 20 – 30 60 75 85 73 175G5237 1,470MCD 202-055-T6-CV3 IP 20 30 40 75 100 100 96 175G5238 1,665MCD 202-075-T6-CV3 IP 00 40/50 50 100 125 140 120 175G5239 1,930MCD 202-090-T6-CV3 IP 00 60 60 125 150 170 142 175G5240 2,300MCD 202-110-T6-CV3 IP 00 – 75 150 200 200 165 175G5241 2,585

Soft Starter List Price

**Normal rating is 40 degree C ambient, 3000 ft, 6 seconds ramp time, 400%

**Heavy rating is 40 degree C ambient, 3000 ft, 20 seconds ramp time, 400%

* Hp ratings are for normal rating

Accessories

ModBus Module 175G9000 $215 ProfiBus Module 175G9001 $300

DeviceNet Module 175G9002 $265 Remote Keypad & Operator Kit 175G9004 $265

Finger Guard Kit 175G9007 $195 Remote Keypad only 175G3061 $175

Control VoltageCV1 = 24 VAC/DC

CV3 = 110-240 VAC 380-440 VAC

Page 37: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

37 06/30/11MCD PL

MCD 500 Soft Starter

*AC-53 Rating for Control Voltage CV1 = 24 VAC/VDC CV2 = 110 or 220 VAC

200 - 525 V (T5) Rating Bypass Part NumberList Price

Current Ratings Frame Description kW Hp Normal Heavy Severe Non Bypass CV1 CV2

G1B No Fan

MCD5-0021B-T5-G1X-20-CV_ 7.5 10 21 17 15 BP 175G5500 175G5525 $940 MCD5-0037B-T5-G1X-20-CV_ 15 20 37 31 26 BP 175G5501 175G5526 $1,095 MCD5-0043B-T5-G1X-20-CV_ 18.5 25 43 37 30 BP 175G5502 175G5527 $1,110 MCD5-0053B-T5-G1X-20-CV_ 22 30 53 46 37 BP 175G5503 175G5528 $1,125 MCD5-0068B-T5-G1X-20-CV_ 30 40 68 55 47 BP 175G5504 175G5529 $1,165 MCD5-0084B-T5-G1X-20-CV_ 37 50 84 69 58 BP 175G5505 175G5530 $1,375 MCD5-0089B-T5-G1X-20-CV_ 45 60 89 74 61 BP 175G5506 175G5531 $1,540 MCD5-0105B-T5-G1X-20-CV_ 55 75 105 95 78 BP 175G5507 175G5532 $1,695

G2B

MCD5-0131B-T5-G2X-00-CV_ 60 80 131 106 90 BP 175G5508 175G5533 $2,125 MCD5-0141B-T5-G2X-00-CV_ 75 100 141 121 97 BP 175G5509 175G5534 $2,400 MCD5-0195B-T5-G2X-00-CV_ 90 125 195 160 134 BP 175G5510 175G5535 $2,895 MCD5-0215B-T5-G2X-00-CV_ 110 150 215 178 149 BP 175G5511 175G5536 $2,995

G3C MCD5-0245C-T5-G3X-00-CV_ 132 175 245/255 195/201 171/176 NBP 175G5512 175G5537 $3,100

G4C

MCD5-0360C-T5-G4X-00-CV_ 160 200 360/360 303/310 259/263 NBP 175G5513 175G5538 $3,200 MCD5-0380C-T5-G4X-00-CV_ 185 250 380/380 348/359 292/299 NBP 175G5514 175G5539 $3,275 MCD5-0428C-T5-G4X-00-CV_ 220 300 428/430 355/368 301/309 NBP 175G5515 175G5540 $3,425 MCD5-0595C-T5-G4X-00-CV_ 300 400 595/620 515/540 419/434 NBP 175G5516 175G5541 $4,200 MCD5-0619C-T5-G4X-00-CV_ 315 500 619/650 532/561 437/455 NBP 175G5517 175G5542 $4,775 MCD5-0790C-T5-G4X-00-CV_ 400 600 790/790 694/714 567/579 NBP 175G5518 175G5543 $5,995 MCD5-0927C-T5-G4X-00-CV_ 500 700 927/930 800/829 644/661 NBP 175G5519 175G5544 $8,695

G5CMCD5-1200C-T5-G5X-00-CV_ 600 800 1200/1200 1135/1200 983/1071 NBP 175G5520 175G5545 $11,995 MCD5-1410C-T5-G5X-00-CV_ 700 900 1410/1410 1187/1319 1023/1114 NBP 175G5523 175G5546 $14,525 MCD5-1600C-T5-G5X-00-CV_ 800 1000 1600/1600 1433/1600 1227/1353 NBP 175G5524 175G5547 $17,375

380 - 690 V (T7) Rating Bypass Part NumberList Price

Current Ratings Frame Description kW Hp Normal Heavy Severe Non Bypass CV1 CV2

G1B

MCD5-0021B-T7-G1X-20-CV_ 7.5 10 21 17 15 BP 175G5548 175G5571 $1,175 MCD5-0037B-T7-G1X-20-CV_ 15 20 37 31 26 BP 175G5549 175G5572 $1,220 MCD5-0043B-T7-G1X-20-CV_ 18.5 25 43 37 30 BP 175G5550 175G5573 $1,225 MCD5-0053B-T7-G1X-20-CV_ 22 30 53 46 37 BP 175G5551 175G5574 $1,245 MCD5-0068B-T7-G1X-20-CV_ 30 40 68 55 47 BP 175G5552 175G5575 $1,285 MCD5-0084B-T7-G1X-20-CV_ 37 50 84 69 58 BP 175G5553 175G5576 $1,510 MCD5-0089B-T7-G1X-20-CV_ 45 60 89 74 61 BP 175G5554 175G5577 $1,675 MCD5-0105B-T7-G1X-20-CV_ 55 75 105 95 78 BP 175G5555 175G5578 $1,840

G2B

MCD5-0131B-T7-G2X-00-CV_ 60 80 131 106 90 BP 175G5556 175G5579 $2,260 MCD5-0141B-T7-G2X-00-CV_ 75 100 141 121 97 BP 175G5557 175G5580 $2,555 MCD5-0195B-T7-G2X-00-CV_ 90 125 195 160 134 BP 175G5558 175G5581 $3,055 MCD5-0215B-T7-G2X-00-CV_ 110 150 215 178 149 BP 175G5559 175G5582 $3,150

G3C MCD5-0245C-T7-G3X-00-CV_ 132 175 245/255 195/201 171/176 NBP 175G5560 175G5583 $3,260

G4C

MCD5-0360C-T7-G4X-00-CV_ 160 200 360/360 303/310 259/263 NBP 175G5561 175G5584 $3,365 MCD5-0380C-T7-G4X-00-CV_ 185 250 380/380 348/359 292/299 NBP 175G5562 175G5585 $3,440 MCD5-0428C-T7-G4X-00-CV_ 220 300 428/430 355/368 301/309 NBP 175G5563 175G5586 $3,590 MCD5-0595C-T7-G4X-00-CV_ 300 400 595/620 515/540 419/434 NBP 175G5564 175G5587 $4,375 MCD5-0619C-T7-G4X-00-CV_ 315 500 619/650 532/561 437/455 NBP 175G5565 175G5588 $4,965 MCD5-0790C-T7-G4X-00-CV_ 400 600 790/790 694/714 567/579 NBP 175G5566 175G5589 $6,220 MCD5-0927C-T7-G4X-00-CV_ 500 700 927/930 800/829 644/661 NBP 175G5567 175G5590 $8,960

G5CMCD5-1200C-T7-G5X-00-CV_ 600 800 1200/1200 1135/1200 983/1071 NBP 175G5568 175G5591 $12,325 MCD5-1410C-T7-G5X-00-CV_ 700 900 1410/1410 1187/1319 1023/1114 NBP 175G5569 175G5592 $14,925 MCD5-1600C-T7-G5X-00-CV_ 800 1000 1600/1600 1433/1600 1227/1353 NBP 175G5570 175G5593 $17,810

Accessories Remote Keypad 175G3061 $175

Remote Operator & Interface Kit 175G9004 $265 MCD Modbus Module 175G9000 $215 MCD Profibus Module 175G9001 $300

MCD DeviceNet Module 175G9002 $265 MCD USB Module 175G9009 $270

IP 20 Finger Guard Kit MCD5-0068B-MCD5-0105B (G2) 175G5662 $195 MCD5-0131B-MCD5-0215B (G3) 175G5663 $505 MCD5-0245B-MCD5-0927B (G4) 175G5664 $750 MCD5-1200B-MCD5-1600B (G5) 175G5665 $755

Page 38: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

38 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

Effective April 5, 2010

Contents and General Information

VLT® Automation, AQUA and HVAC Drives and Standard Panels

208 & 230 volt drives and standard panels . . . . 39

460 volt drives and standard panels . . . . . . . . . . 44

575 volt drives and standard panels . . . . . . . . . . 51

Drive Terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

Designations• All prices are factory list prices in US$

Policies• DrivePro parts multipliers apply to fuse pricing

• Terms = NET 30 Days

• Prices are subject to change without notice.

• Freight is not included.

Freight• Fuses to be shipped with a drive may be shipped at no extra

chargeforthe“Prepayanddonotadd”rateslistedinthedriveprice list.

• Fusesorderedforseparateshipmentwillbeshipped“collect”.The customer is responsible for selecting the carrier and indicating their choice on the purchase order. Danfoss will schedule pick-up. The customer is responsible for paying the carrier for the shipment.

• Danfoss reserves the right to select the freight carrier unless specified by the customer.

Fuse selection• Replacementfuselistsarearrangedbyvoltagethepowersize.ThevariabletorquecolumnsapplytotheVLT® AQUA and

HVACDrives.TheconstanttorquecolumnappliestotheVLT®AutomationDrive.

• Replacement fuses for the drives are listed first, followed by bypass panel fuses and dual motor branch circuit protection fuses.Selectallofthefuseslistedforthevoltageandpowersizetocompilealistofallsparefusesforaspecificdriveordrive panel configuration.

• Consult the factory for replacement fuses for custom panel configurations.

Page 39: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

39 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

208 & 230 V FusesDrive Fuses

208 - 230v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 208/230 v

Ordering number Qty per drive List price Constant torque high OL

HP or FLA @ 208 / 230 vOrdering number Qty per drive List price

Drive Input fuse

PK37 0.5 Hp 176F8945 1 package of 3 43.00 / pack 0.5 Hp 176F8945 1 package of 3 43.00 / pack

PK55 0.75 Hp 176F8947 1 package of 3 38.90 / pack 0.75 Hp 176F8947 1 package of 3 38.90 / pack

PK75 1 Hp 176F8947 1 package of 3 38.90 / pack 1 Hp 176F8947 1 package of 3 38.90 / pack

P1K1 1.5 Hp 176F8947 1 package of 3 38.90 / pack 1.5 Hp 176F8947 1 package of 3 38.90 / pack

P1K5 2 Hp 176F8948 1 package of 3 38.90 / pack 2 Hp 176F8948 1 package of 3 38.90 / pack

P2K2 3 Hp 176F8949 1 package of 3 38.90 / pack 3 Hp 176F8949 1 package of 3 38.90 / pack

P3K7 5 Hp 176F8951 1 package of 3 38.90 / pack 5 Hp 176F8951 1 package of 3 38.90 / pack

P5K5 7.5 Hp 176F8953 1 package of 3 48.00 / pack 7.5 Hp 176F8953 1 package of 3 48.00 / pack

P7K5 10 Hp 176F8953 1 package of 3 48.00 / pack 10 Hp 176F8955 1 package of 3 48.10 / pack

P11K 15 Hp 176F8955 1 package of 3 48.10 / pack 15 Hp 176F8957 1 package of 3 56.60 / pack

P15K 20 Hp 176F8957 1 package of 3 56.60 / pack 20 Hp 176F8960 1 package of 3 92.20 / pack

P18K5 25 Hp 176F8960 1 package of 3 92.20 / pack 25 Hp 176F8960 1 package of 3 92.20 / pack

P22K 30 Hp 176F8960 1 package of 3 92.20 / pack 30 Hp 176F8962 1 package of 3 102.60 / pack

P30K 40 Hp 176F8962 1 package of 3 102.60 / pack 40 Hp 176F8964 1 package of 3 87.90 / pack

P37K 50 Hp 176F8964 1 package of 3 87.90 / pack 50 Hp 176F8965 1 package of 3 87.90 / pack

P45K 60 Hp 176F8965 1 package of 3 87.90 / pack

Bypass Main Fuses

208 - 230v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 208/230 v

Ordering number Qty per drive List price Constant torque high OL

HP or FLA @ 208 / 230 vOrdering number Qty per drive List price

Bypass main fuse (all enclosure types)

H50 0.5 Hp 34034900 3 51.30 each 0.5 Hp 34034900 3 51.30 each

H75 0.75 Hp 34035000 3 15.50 each 0.75 Hp 34035000 3 15.50 each

001 1 Hp 176U5836 3 15.50 each 1 Hp 176U5836 3 15.50 each

1H5 1.5 Hp 34042500 3 15.50 each 1.5 Hp 34042500 3 15.50 each

002 2 Hp 34035200 3 15.50 each 2 Hp 34035200 3 15.50 each

003 3 Hp 34035400 3 15.50 each 3 Hp 34035400 3 15.50 each

005 5 Hp 34035500 3 15.50 each 5 Hp 34035500 3 15.50 each

7H5 7.5 Hp 34035600 3 18.70 each 7.5 Hp 34035600 3 18.70 each

010 10 Hp 34035700 3 20.60 each 10 Hp 34035700 3 20.60 each

015 15 Hp 34042800 3 47.60 each 15 Hp 34042800 3 47.60 each

020 20 Hp 34042900 3 54.50 each 20 Hp 34042900 3 54.50 each

025 25 Hp 34043100 3 74.20 each 25 Hp 34043100 3 74.20 each

030 30 Hp 34043200 3 68.70 each 30 Hp 34043200 3 68.70 each

040 40 Hp 34043300 3 74.20 each 40 Hp 34043300 3 74.20 each

050 50 Hp 34042300 3 185.80 each 50 Hp 34042300 3 185.80 each

060 60 Hp 34042300 3 185.80 each

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

Page 40: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

40 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

208 & 230 V Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

N1 / N12 Bypass or CMS fuses

208 - 230v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @ 208/230 v

Ordering number Qty per drive List price Constant torque high OL HP

or FLA @ 208 / 230 vOrdering number Qty per drive List price

UL / NEMA type 1 & 12 Bypass or CMS power supply primary fuse*

All All Hp 612Z1291 3 5.20 each All Hp 612Z1291 3 5.20 each

* NOTE: 20 amp fuse 612Z1291 replaces 4 amp fuse 612Z1184 originally supplied to improve ride-through of voltage spikes caused by switching the panel input to an emergency genenrator or by utilitily power factor correction switching

UL / NEMA type 1 & 12 Bypass or CMS transformer primary fuse

040 40 Hp 34046200 2 7.70 each 30 Hp 34046200 2 7.70 each

050 50 Hp 34046200 2 7.70 each 40 Hp 34046200 2 7.70 each

060 60 Hp 34046200 2 7.70 each 50 Hp 34046200 2 7.70 each

UL / NEMA type 1 & 12 Bypass or CMS transformer secondary fuse

040 40 Hp 34045500 1 3.80 each 30 Hp 34045500 1 3.80 each

050 50 Hp 34045500 1 3.80 each 40 Hp 34045500 1 3.80 each

060 60 Hp 34045500 1 3.80 each 50 Hp 34045500 1 3.80 each

Page 41: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

41 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

208 & 230 V UL / NEMA Type 1 & 12 Dual Motor Fuses

208v N1 / N12 Dual Motor fuses

208 - 230v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @ 208/230 v

Ordering number Qty per drive List price Constant torque high OL

HP or FLA @ 208 / 230 vOrdering number Qty per drive List price

UL / NEMA type 1 & 12 Dual motor fuses

A 0.5 Hp @208v 34034900 3 per motor 51.30 each 0.5 Hp @208v 34034900 3 per motor 51.30 each

B 0.75 Hp @ 208v 34035000 3 per motor 15.50 each 0.75 Hp @ 208v 34035000 3 per motor 15.50 each

C 1.0 Hp @ 208v 176U5836 3 per motor 15.50 each 1.0 Hp @ 208v 176U5836 3 per motor 15.50 each

D 1.5 Hp @ 208v 34042500 3 per motor 15.50 each 1.5 Hp @ 208v 34042500 3 per motor 15.50 each

E 2.0 Hp @ 208v 34035200 3 per motor 15.50 each 2.0 Hp @ 208v 34035200 3 per motor 15.50 each

F 3.0 Hp @ 208v 34035400 3 per motor 15.50 each 3.0 Hp @ 208v 34035400 3 per motor 15.50 each

G 5.0 Hp @ 208v 34035500 3 per motor 15.50 each 5.0 Hp @ 208v 34035500 3 per motor 15.50 each

H 7.5 Hp @ 208v 34035600 3 per motor 18.70 each 7.5 Hp @ 208v 34035600 3 per motor 18.70 each

I 10 Hp @ 208v 34035700 3 per motor 20.60 each 10 Hp @ 208v 34035700 3 per motor 20.60 each

J 15 Hp @ 208v 34042800 3 per motor 47.60 each 15 Hp @ 208v 34042800 3 per motor 47.60 each

K 20 Hp @ 208v 34042900 3 per motor 54.50 each 20 Hp @ 208v 34042900 3 per motor 54.50 each

L 25 Hp @ 208v 34043100 3 per motor 74.20 each 25 Hp @ 208v 34043100 3 per motor 74.20 each

M 30 Hp @ 208v 34043200 3 per motor 68.70 each 30 Hp @ 208v 34043200 3 per motor 68.70 each

N 40 Hp @ 208v 34043300 3 per motor 74.20 each 40 Hp @ 208v 34043300 3 per motor 74.20 each

O 50 Hp @ 208v 34042300 3 per motor 185.80 each 50 Hp @ 208v 34042300 3 per motor 185.80 each

P 60 Hp @ 208v 34042300 3 per motor 185.80 each 60 Hp @ 208v 34042300 3 per motor 185.80 each

230v N1 / 12 Dual Motor fusesA 0.5 Hp @ 230v 34034900 3 per motor 51.30 each 0.5 Hp @ 230v 34034900 3 per motor 51.30 each

B 0.75 Hp @ 230v 176U5835 3 per motor 15.50 each 0.75 Hp @ 230v 176U5835 3 per motor 15.50 each

C 1.0 Hp @ 230v 176U5836 3 per motor 15.50 each 1.0 Hp @ 230v 176U5836 3 per motor 15.50 each

D 1.5 Hp @ 230v 34042500 3 per motor 15.50 each 1.5 Hp @ 230v 34042500 3 per motor 15.50 each

E 2.0 Hp @ 230v 34042500 3 per motor 15.50 each 2.0 Hp @ 230v 34042500 3 per motor 15.50 each

F 3.0 Hp @ 230v 34035300 3 per motor 15.50 each 3.0 Hp @ 230v 34035300 3 per motor 15.50 each

G 5.0 Hp @ 230v 176U5837 3 per motor 15.50 each 5.0 Hp @ 230v 176U5837 3 per motor 15.50 each

H 7.5 Hp @ 230v 34042600 3 per motor 18.70 each 7.5 Hp @ 230v 34042600 3 per motor 18.70 each

I 10 Hp @ 230v 34042700 3 per motor 18.70 each 10 Hp @ 230v 34042700 3 per motor 18.70 each

J 15 Hp @ 230v 34042800 3 per motor 47.60 each 15 Hp @ 230v 34042800 3 per motor 47.60 each

K 20 Hp @ 230v 34042900 3 per motor 54.50 each 20 Hp @ 230v 34042900 3 per motor 54.50 each

L 25 Hp @ 230v 34043000 3 per motor 47.60 each 25 Hp @ 230v 34043000 3 per motor 47.60 each

M 30 Hp @ 230v 34043100 3 per motor 74.20 each 30 Hp @ 230v 34043100 3 per motor 74.20 each

N 40 Hp @ 230v 34043200 3 per motor 68.70 each 40 Hp @ 230v 34043200 3 per motor 68.70 each

O 50 Hp @ 230v 34043400 3 per motor 79.20 each 50 Hp @ 230v 34043400 3 per motor 79.20 each

P 60 Hp @ 230v 34042300 3 per motor 185.80 each 60 Hp @ 230v 34042300 3 per motor 185.80 each

Page 42: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

42 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

208 & 230 V N3R Bypass Fuses

208 - 230v HVAC FC102 / AQUA FC202 units

Drive Power size (Drive = kW, Panel = Hp) Variable torque HP or FLA @ 208/230 v Ordering number Qty per drive List price

UL/NEMA type 3R Bypass / CMS transformer primary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

H50 - 10 0.5 - 10 Hp 176U5398 2 7.90 each

15 - 20 15 - 20 Hp 176U5402 2 7.90 each

25 - 30 w/ Bypass or CMS 25 - 30 Hp w/ Bypass or CMS 176U5403 2 7.90 each

25 - 30 w/ Bypass and CMS 25 - 30 Hp w/ Bypass and CMS 176U5404 2 7.90 each

UL/NEMA type 3R Bypass / CMS transformer secondary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

15 - 20 15 - 20 Hp 34053800 1 3.80 each

25 - 30 @ 208v 25 - 30 Hp @ 208v 34053800 1 3.80 each

25 - 30 @ 230v w/ Bypass or CMS 25 - 30 Hp @ 230v w/ Bypass or CMS 34053900 1 3.80 each

25 - 30 @ 230v w/ Bypass and CMS 25 - 30 Hp @ 230v w/ Bypass and CMS 34054000 1 3.70 each

UL/NEMA type 3R fan and heater PS transformer primary fuse

All @ 208 volt All Hp @ 208 volt 176U5402 1 7.90 each

All @ 230 volt All Hp @ 230 volt 176U5401 1 7.90 each

Page 43: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

43 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

208 & 230 V UL/NEMA Type 3R Dual Motor Fuses

208v N3R Dual Motor fuses

208 - 230v HVAC FC102 / AQUA FC202 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 208/230 v Ordering number Qty per drive List price

D 1.8 - 2.6A @ 208v 34034900 3 per motor 51.30 each

E 2.7 - 4.0A @ 208v 34035000 3 per motor 15.50 each

F 4.1 - 6.3A @ 208v 34042500 3 per motor 15.50 each

G 6.4 - 8.5A @ 208v 34035300 3 per motor 15.50 each

H 8.6 - 10.5A @ 208v 34035300 3 per motor 15.50 each

I 10.6 - 14.4A @ 208v 34035400 3 per motor 15.50 each

J 14.5 - 18.0A @ 208v 176U5837 3 per motor 15.50 each

K 21.0 - 25.5A @ 208v 34042600 3 per motor 18.70 each

L 25.6 - 32.0A @ 208v 34042700 3 per motor 18.70 each

M 32.1 - 38.0A @ 208v 34035700 3 per motor 20.60 each

N 38.1 - 42.0A @ 208v 34035800 3 per motor 18.70 each

P 42.1 - 54.0A @ 208v 34042800 3 per motor 47.60 each

Q 54.1 - 64.0A @ 208v 34042900 3 per motor 54.50 each

R 64.1 - 82.0A @ 208v 34043100 3 per motor 74.20 each

S 83.0 - 89.0A @ 208v 34043100 3 per motor 74.20 each

T 90.0 - 109A @ 208v 34043200 3 per motor 68.70 each

U 110 - 140A @ 208v 34043300 3 per motor 74.20 each

230v N3R Dual Motor fuses D 1.8 - 2.6A @ 230v 34034900 3 per motor 51.30 each

E 2.7 - 4.0A @ 230v 34035000 3 per motor 15.50 each

F 4.1 - 6.3A @ 230v 34042500 3 per motor 15.50 each

G 6.4 - 8.5A @ 230v 34035300 3 per motor 15.50 each

H 8.6 - 10.5A @ 230v 34035300 3 per motor 15.50 each

I 10.6 - 14.4A @ 230v 34035400 3 per motor 15.50 each

J 14.5 - 18.0A @ 230v 176U5837 3 per motor 15.50 each

K 21.0 - 25.5A @ 230v 34042600 3 per motor 18.70 each

L 25.6 - 32.0A @ 230v 34042700 3 per motor 18.70 each

M 32.1 - 38.0A @ 230v 34035700 3 per motor 20.60 each

N 38.1 - 42.0A @ 230v 34035800 3 per motor 18.70 each

P 42.1 - 54.0A @ 230v 34042800 3 per motor 47.60 each

Q 54.1 - 64.0A @ 230v 34042900 3 per motor 54.50 each

R 64.1 - 82.0A @ 230v 34049900 3 per motor 72.80 each

S 83.0 - 89.0A @ 230v 34043100 3 per motor 74.20 each

T 90.0 - 109A @ 230v 34043200 3 per motor 68.70 each

U 110 - 140A @ 230v 34043300 3 per motor 74.20 each

Page 44: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

44 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses VLT® Drive and Standard Panel Replacement Fuses

460 V Drive Fuses

460v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW,

Panel = Hp)

Variable torque HP or FLA @

460 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 460 vOrdering number Qty per drive List price

Drive Input fuse

PK37 0.5 Hp 176F8946 1 package of 3 34.20 / pack 0.5 Hp 176F8946 1 package of 3 34.20 / pack

PK55 0.75 Hp 176F8946 1 package of 3 34.20 / pack 0.75 Hp 176F8946 1 package of 3 34.20 / pack

PK75 1 Hp 176F8946 1 package of 3 34.20 / pack 1 Hp 176F8946 1 package of 3 34.20 / pack

P1K1 1.5 Hp 176F8946 1 package of 3 34.20 / pack 1.5 Hp 176F8946 1 package of 3 34.20 / pack

P1K5 2 Hp 176F8947 1 package of 3 38.90 / pack 2 Hp 176F8947 1 package of 3 38.90 / pack

P2K2 3 Hp 176F8947 1 package of 3 38.90 / pack 3 Hp 176F8947 1 package of 3 38.90 / pack

P4K0 5 Hp 176F8949 1 package of 3 38.90 / pack 5 Hp 176F8949 1 package of 3 38.90 / pack

P5K5 7.5 Hp 176F8950 1 package of 3 38.90 / pack 7.5 Hp 176F8950 1 package of 3 38.90 / pack

P7K5 10 Hp 176F8951 1 package of 3 38.90 / pack 10 Hp 176F8951 1 package of 3 38.90 / pack

P11K 15 Hp 176F8952 1 package of 3 52.90 / pack 15 Hp 176F8952 1 package of 3 52.90 / pack

P15K 20 Hp 176F8952 1 package of 3 52.90 / pack 20 Hp 176F8954 1 package of 3 59.80 / pack

P18K 25 Hp 176F8954 1 package of 3 59.80 / pack 25 Hp 176F8956 1 package of 3 53.40 / pack

P22K 30 Hp 176F8956 1 package of 3 53.40 / pack 30 Hp 176F8958 1 package of 3 78.70 / pack

P30K 40 Hp 176F8958 1 package of 3 78.70 / pack 40 Hp 176F8959 1 package of 3 80.60 / pack

P37K 50 Hp 176F8959 1 package of 3 80.60 / pack 50 Hp 176F8961 1 package of 3 117.30 / pack

P45K 60 Hp 176F8961 1 package of 3 117.30 / pack 60 Hp 176F9078 1 package of 3 194.70 / pack

P55K 75 Hp 176F9078 1 package of 3 194.70 / pack 75 Hp 176F9079 1 package of 3 65.20 / pack

P75K 100 Hp 176F9079 1 package of 3 65.20 / pack 100 Hp 176F8944 1 package of 3 88.80 / pack

P90K 125 Hp 176F8944 1 package of 3 88.80 / pack 125 Hp 176F8334 3 56.40 each

P110 150 Hp 176F8334 3 56.40 each 150 Hp 176F8334 3 56.40 each

P132 200 Hp 176F8334 3 56.40 each 200 Hp 176F8335 3 65.60 each

P160 250 Hp 176F8335 3 65.60 each 250 Hp 176F8335 3 65.60 each

P200 300 Hp 176F8335 3 65.60 each 300 Hp 176F8335 3 65.60 each

P250 350 Hp 176F8335 3 65.60 each 350 Hp 176F8591 3 106.60 each

P315 400 Hp 176F8591 3 106.60 each 450 Hp 176F8592 3 160.10 each

P355 450 Hp 176F8592 3 160.10 each 500 Hp 176F8592 3 160.10 each

P400 500 Hp 176F8592 3 160.10 each 550 Hp 176F8592 3 160.10 each

P450 600 Hp 176F8592 3 160.10 each 600 Hp 176F8769 3 659.20 each

P500 650 Hp 176F8769 3 659.20 each 650 Hp 176F8769 3 659.20 each

P560 750 Hp 176F8769 3 659.20 each 750 Hp 176F8769 3 659.20 each

P630 900 Hp 176F8769 3 659.20 each 900 Hp 176F8769 3 659.20 each

P710 1000 Hp 176F8769 3 659.20 each 1000 Hp 176F8770 3 735.30 each

P800 1200 Hp 176F8770 3 735.30 each 1200 Hp 176F8770 3 735.30 each

P1M0 1350 Hp 176F8770 3 735.30 each

DC Fuse (F Frame drives)

P450 - - - - 600 Hp 176F8767 4 296.30 each

P500 650 Hp 176F8767 4 296.30 each 650 Hp 176F8767 4 296.30 each

P560 750 Hp 176F8767 4 296.30 each 750 Hp 176F8768 4 261.10 each

P630 900 Hp 176F8768 4 261.10 each 900 Hp 176F8768 4 261.10 each

P710 1000 Hp 176F8768 4 261.10 each 1000 Hp 176F8767 6 296.30 each

P800 1200 Hp 176F8767 6 296.30 each 1200 Hp 176F8768 6 261.10 each

P1M0 1350 Hp 176F8768 6 261.10 each - - - -

Page 45: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

45 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V Fuses

460v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW,

Panel = Hp)

Variable torque HP or FLA @

460 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 460 v

Ordering number Qty per drive List price

Drive soft charge fuse

P90K - P450 125 - 600 176F8336 1 package of 3 29.10 / pack 125 - 550 176F8336 1 package of 3 29.10 / pack

P450 - P710 650 - 1000 176F8336 2 package of 3 29.10 / pack 600 - 900 176F8336 2 package of 3 29.10 / pack

P710 - P1M0 1200 - 1350 176F8336 3 package of 3 29.10 / pack 1000 - 1200 176F8336 3 package of 3 29.10 / pack

Drive Power card fuse (F Frame = 1 pack / Rectifier & Inverter section)

P90K - P450 125 - 600 176F8440 1 package of 3 17.40 / pack 125 - 550 176F8440 1 package of 3 17.40 / pack

P450 - P710 F Frame 650 - 1000 176F8440 3 package of 3 17.40 / pack 600 - 900 176F8440 3 package of 3 17.40 / pack

P710 - P1M0 F Frame 1200 - 1350 176F8440 4 package of 3 17.40 / pack 1000 - 1200 176F8440 4 package of 3 17.40 / pack

Drive Fan transformer fuse

P90K - P315 125 - 400 176F8440 1 package of 3 17.40 / pack 125 - 350 176F8440 1 package of 3 17.40 / pack

P315 - P450 450 - 600 176F8440 1 package of 3 17.40 / pack 400 - 550 176F8440 1 package of 3 17.40 / pack

P450 - P710 650 - 1000 176F8609 2 package of 3 50.30 / pack 600 - 900 176F8609 2 package of 3 50.30 / pack

P710 - P1M0 1200 - 1300 176F8609 3 package of 3 50.30 / pack 1000 - 1200 176F8609 3 package of 3 50.30 / pack

Page 46: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

46 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V Bypass Main Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

460v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW,

Panel = Hp)

Variable torque HP or FLA @

460 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 460 vOrdering number Qty per drive List price

Bypass main fuse

H50 0.5 Hp 176U5277 3 14.90 each 0.5 176U5277 3 14.90 each

H75 0.75 Hp 176U5834 3 15.50 each 0.75 176U5834 3 15.50 each

001 1 Hp 176U5834 3 15.50 each 1 Hp 176U5834 3 15.50 each

1H5 1.5 Hp 34034900 3 51.30 each 1.5 Hp 34034900 3 51.30 each

002 2 Hp 34035000 3 15.50 each 2 Hp 34035000 3 15.50 each

003 3 Hp 34035100 3 15.50 each 3 Hp 34035000 3 15.50 each

005 5 Hp 34035200 3 15.50 each 5 Hp 34035100 3 15.50 each

7H5 7.5 Hp 34035400 3 15.50 each 7.5 Hp 34035200 3 15.50 each

010 10 Hp 176U5837 3 15.50 each 10 Hp 176U5837 3 15.50 each

015 15 Hp 34042600 3 18.70 each 15 Hp 34042600 3 18.70 each

020 20 Hp 34035600 3 18.70 each 20 Hp 34035600 3 18.70 each

025 25 Hp 34035700 3 20.60 each 25 Hp 34035700 3 20.60 each

030 30 Hp 34035800 3 18.70 each 30 Hp 34035800 3 18.70 each

040 40 Hp 176U5037 3 54.50 each 40 Hp 176U5037 3 54.50 each

050 50 Hp 34043000 3 47.60 each 50 Hp 34043000 3 47.60 each

060 60 Hp 34043100 3 74.20 each 60 Hp 34043100 3 74.20 each

075 75 Hp 34043200 3 68.70 each 75 Hp 34043200 3 68.70 each

100 100 Hp 34043400 3 79.20 each 100 Hp 34043400 3 79.20 each

125 125 Hp 34042300 3 185.80 each 125 Hp 34042300 3 185.80 each

150 150 Hp 34042400 3 185.80 each 150 Hp 34042400 3 185.80 each

200 200 Hp 34043600 3 185.80 each 200 Hp 34043600 3 185.80 each

250 250 Hp 34043700 3 225.00 each 250 Hp 34043700 3 225.00 each

300 300 Hp 176U5669 3 417.30 each 300 Hp 176U5669 3 417.30 each

350 350 Hp 176U5669 3 417.30 each

Page 47: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

47 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V N1 / N12 Bypass or CMS Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

460v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW,

Panel = Hp)

Variable torque HP or FLA @

460 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 460 vOrdering number Qty per drive List price

UL / NEMA type 1 & 12 Bypass or CMS power supply primary fuse

All All Hp 612Z1291 3 5.20 each All Hp 612Z1291 3 5.20 each

* NOTE: 20 amp fuse 612Z1291 replaces 4 amp fuse 612Z1184 originally supplied to improve ride-through of voltage spikes caused by switching the panel input to an emergency genenrator or by utilitily power factor correction switching

UL / NEMA type 1 & 12 Bypass or CMS transformer primary fuse

100 100 Hp 34046000 2 7.70 each 100 Hp 34046000 2 7.70 each

125 125 Hp 34046000 2 7.70 each 125 Hp 34046000 2 7.70 each

150 150 Hp 176U5402 2 7.90 each 150 Hp 176U5402 2 7.90 each

200 200 Hp 176U5402 2 7.90 each 200 Hp 176U5402 2 7.90 each

250 250 Hp 176U5402 2 7.90 each 250 Hp 176U5402 2 7.90 each

300 300 Hp 176U5405 2 7.90 each 300 Hp 176U5405 2 7.90 each

350 350 Hp 176U5405 2 7.90 each 350 Hp 176U5405 2 7.90 each

UL / NEMA type 1 & 12 Bypass or CMS transformer secondary fuse

100 100 Hp 34045500 1 3.80 each 100 Hp 34045500 1 3.80 each

125 125 Hp 34045500 1 3.80 each 125 Hp 34045500 1 3.80 each

150 150 Hp 176U5634 1 7.90 each 150 Hp 176U5634 1 7.90 each

200 200 Hp 176U5634 1 7.90 each 200 Hp 176U5634 1 7.90 each

250 250 Hp 176U5634 1 7.90 each 250 Hp 176U5634 1 7.90 each

300 300 Hp 176U5516 1 7.90 each 300 Hp 176U5516 1 7.90 each

350 350 Hp 176U5516 1 7.90 each 350 Hp 176U5516 1 7.90 each

Page 48: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

48 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V N1 / N12 Dual Motor Fuses

460v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW,

Panel = Hp)

Variable torque HP or FLA @

460 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 460 v

Ordering number Qty per drive List price

UL / NEMA type 1 & 12 Dual motor fuses

A 0.5 Hp 176U5277 3 per motor 14.90 each 0.5 Hp 176U5277 3 per motor 14.90 each

B 0.75 Hp 176U5834 3 per motor 15.50 each 0.75 Hp 176U5834 3 per motor 15.50 each

C 1 Hp 176U5834 3 per motor 15.50 each 1 Hp 176U5834 3 per motor 15.50 each

D 1.5 Hp 34034900 3 per motor 51.30 each 1.5 Hp 34034900 3 per motor 51.30 each

E 2 Hp 34035000 3 per motor 15.50 each 2 Hp 34035000 3 per motor 15.50 each

F 3 Hp 34035100 3 per motor 15.50 each 3 Hp 34035100 3 per motor 15.50 each

G 5 Hp 34035200 3 per motor 15.50 each 5 Hp 34035200 3 per motor 15.50 each

H 7.5 Hp 34035400 3 per motor 15.50 each 7.5 Hp 34035400 3 per motor 15.50 each

I 10 Hp 34035400 3 per motor 15.50 each 10 Hp 34035400 3 per motor 15.50 each

J 15 Hp 34042600 3 per motor 18.70 each 15 Hp 34042600 3 per motor 18.70 each

K 20 Hp 34035600 3 per motor 18.70 each 20 Hp 34035600 3 per motor 18.70 each

L 25 Hp 34035700 3 per motor 20.60 each 25 Hp 34035700 3 per motor 20.60 each

M 30 Hp 34035800 3 per motor 18.70 each 30 Hp 34035800 3 per motor 18.70 each

N 40 Hp 176U5037 3 per motor 54.50 each 40 Hp 176U5037 3 per motor 54.50 each

O 50 Hp 34043000 3 per motor 47.60 each 50 Hp 34043000 3 per motor 47.60 each

P 60 Hp 34043100 3 per motor 74.20 each 60 Hp 34043100 3 per motor 74.20 each

Q 75 Hp 34043200 3 per motor 68.70 each 75 Hp 34043200 3 per motor 68.70 each

R 100 Hp 34043400 3 per motor 79.20 each 100 Hp 34043400 3 per motor 79.20 each

S 125 Hp 34042300 3 per motor 185.80 each 125 Hp 34042300 3 per motor 185.80 each

T 150 Hp 34042400 3 per motor 185.80 each 150 Hp 34042400 3 per motor 185.80 each

Page 49: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

49 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V N3R Bypass & CMS Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

460v HVAC FC102 / AQUA FC202 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 460 v Ordering number Qty per drive List price

UL/NEMA type 3R Bypass / CMS transformer primary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

H50 - 25 0.5 - 25 Hp 176U5397 2 7.90 each

30 - 40 30 - 40 Hp 176U5398 2 7.90 each

50 - 75 w/ Bypass or CMS 50 - 75 Hp w/ Bypass or CMS 176U5398 2 7.90 each

50 - 75 w/ Bypass and CMS 50 - 75 Hp w/ Bypass and CMS 176U5400 2 7.90 each

UL/NEMA type 3R Bypass / CMS transformer secondary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

30 - 40 30 - 40 Hp 34053800 1 3.80 each

50 - 75 w/ Bypass or CMS 50 - 75 Hp w/ Bypass or CMS 34053800 1 3.80 each

50 - 75 w/ Bypass and CMS 50 - 75 Hp w/ Bypass and CMS 34053900 1 3.80 each

UL/NEMA type 3R fan and heater PS transformer primary fuse

All @ 208 volt All Hp @ 208 volt 176U5402 1 7.90 each

All @ 230 volt All Hp @ 230 volt 176U5401 1 7.90 each

Page 50: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

50 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

460 V N3R Dual Motor Fuses

460v HVAC FC102 / AQUA FC202 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 460 v Ordering number Qty per drive List price

UL/NEMA type 3R Dual motor fuses

A 0.65 - 1.1A 176U5834 3 per motor 15.50 each

B 1.1 - 1.4A 176U5834 3 per motor 15.50 each

C 1.5 - 1.7A 176U5834 3 per motor 15.50 each

D 1.8 - 2.6A 34034900 3 per motor 51.30 each

E 2.7 - 4.0A 34035000 3 per motor 15.50 each

F 4.1 - 6.3A 34042500 3 per motor 15.50 each

G 6.4 - 8.5A 34035300 3 per motor 15.50 each

H 8.6 - 10.5A 34035300 3 per motor 15.50 each

I 10.6 - 14.4A 34035400 3 per motor 15.50 each

J 14.5 - 18.0A 176U5837 3 per motor 15.50 each

K 21.0 - 25.5A 34042600 3 per motor 18.70 each

L 25.6 - 32.0A 34035600 3 per motor 18.70 each

M 32.1 - 38.0A 34035700 3 per motor 20.60 each

N 38.1 - 42.0A 34035800 3 per motor 18.70 each

P 42.1 - 54.0A 34042800 3 per motor 47.60 each

Q 54.1 - 64.0A 34042900 3 per motor 54.50 each

R 64.1 - 82.0A 34049900 3 per motor 72.80 each

S 83.0 - 89.0A 34043100 3 per motor 74.20 each

T 90.0 - 109A 34043200 3 per motor 68.70 each

Page 51: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

51 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575 V Drive Fuses

575v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @

575 v

Ordering number Qty per drive List price

Constant torque high OL HP or FLA

@ 575 v

Ordering number Qty per drive List price

Drive Input fuse

PK75 1 Hp 176F8945 1 package of 3 43.00 / pack 1 Hp 176F8945 1 package of 3 43.00 / pack

P1K1 1.5 Hp 176F8945 1 package of 3 43.00 / pack 1.5 Hp 176F8945 1 package of 3 43.00 / pack

P1K5 2 Hp 176F8947 1 package of 3 38.90 / pack 2 Hp 176F8947 1 package of 3 38.90 / pack

P2K2 3 Hp 176F8947 1 package of 3 38.90 / pack 3 Hp 176F8947 1 package of 3 38.90 / pack

P4K0 5 Hp 176F8949 1 package of 3 38.90 / pack 5 Hp 176F8949 1 package of 3 38.90 / pack

P5K5 7.5 Hp 176F8950 1 package of 3 38.90 / pack 7.5 Hp 176F8950 1 package of 3 38.90 / pack

P7K5 10 Hp 176F8951 1 package of 3 38.90 / pack 10 Hp 176F8951 1 package of 3 38.90 / pack

P11K 15 Hp 176F9076 1 package of 3 60.90 / pack - - - -

P15K 20 Hp 176F9076 1 package of 3 60.90 / pack 15 Hp 176F9076 1 package of 3 60.90 / pack

P18K 25 Hp 176F9077 1 package of 3 69.50 / pack 20 Hp 176F9077 1 package of 3 69.50 / pack

P22K 30 Hp 176F8954 1 package of 3 59.80 / pack 25 Hp 176F8954 1 package of 3 59.80 / pack

P30K 40 Hp 176F8956 1 package of 3 53.40 / pack 30 Hp 176F8956 1 package of 3 53.40 / pack

P37K 50 Hp 176F8958 1 package of 3 78.70 / pack 40 Hp 176F8958 1 package of 3 78.70 / pack

P45K 60 Hp 176F8959 1 package of 3 80.60 / pack 50 Hp 176F8959 1 package of 3 80.60 / pack

P55K 75 Hp 176F8961 1 package of 3 117.30 / pack 60 Hp 176F8961 1 package of 3 117.30 / pack

P75K 100 Hp 176F9078 1 package of 3 194.70 / pack 75 Hp 176F9078 1 package of 3 194.70 / pack

P90K 125 Hp 176F9075 1 package of 3 199.90 / pack 100 Hp 176F9075 1 package of 3 199.90 / pack

P110 - - - - 125 Hp 176F8334 3 56.40 each

P132 150 Hp 176F8334 3 56.40 each 150 Hp 176F8334 3 56.40 each

P160 200 Hp 176F8334 3 56.40 each 200 Hp 176F8540 3 108.70 each

P200 250 Hp 176F8540 3 108.70 each 250 Hp 176F8540 3 108.70 each

P250 300 Hp 176F8540 3 108.70 each 300 Hp 176F8540 3 108.70 each

P315 350 Hp 176F8540 3 108.70 each 350 Hp 176F8540 3 108.70 each

P355 - - - - 400 Hp 176F8591 3 106.60 each

P400 400 Hp 176F8540 3 108.70 each 400 Hp 176F8591 3 106.60 each

P450 450 Hp 176F8591 3 106.60 each - - - -

P500 500 Hp 176F8591 3 106.60 each 500 Hp 176F8591 3 106.60 each

P560 600 Hp 176F8591 3 106.60 each 600 Hp 176F8592 3 160.10 each

P630 650 Hp 176F8592 3 160.10 each 650 Hp 176F8769 3 659.20 each

P710 750 Hp 176F8769 3 659.20 each 750 Hp 176F8769 3 659.20 each

P800 950 Hp 176F8769 3 659.20 each 950 Hp 176F8769 3 659.20 each

P900 1050 Hp 176F8769 3 659.20 each 1050 Hp 176F8769 3 659.20 each

P1M0 1150 Hp 176F8769 3 659.20 each 1150 Hp 176F8769 3 659.20 each

P1M2 1350 Hp 176F8769 3 659.20 each 1350 Hp 176F8770 3 735.30 each

P1M4 1550 Hp 176F8770 3 735.30 each - - - -

Page 52: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

52 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575 V Fuses

575v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @ 575 v

Ordering number Qty per drive List price

Constant torque high OL HP or FLA

@ 575 v

Ordering number Qty per drive List price

DC Fuse (F Frame drives)

P630 - - - - 650 Hp 176F8767 4 296.30 each

P710 750 Hp 176F8767 4 296.30 each 750 Hp 176F8767 4 296.30 each

P800 950 Hp 176F8767 4 296.30 each 950 Hp 176F8767 4 296.30 each

P900 1050 Hp 176F8767 4 296.30 each 1050 Hp 176F8767 6 296.30 each

P1M0 1150 Hp 176F8767 6 296.30 each 1150 Hp 176F8767 6 296.30 each

P1M2 1350 Hp 176F8767 6 296.30 each 1350 Hp 176F8767 6 296.30 each

P1M4 1550 Hp 176F8767 6 296.30 each - - - -

Drive soft charge fuse

P110 - P630 150 - 650 Hp 176F8336 1 package of 3 29.10 / pack 150 - 650 Hp 176F8336 1 package of 3 29.10 / pack

P630 - P900 F Frame 750 - 950 Hp 176F8336 2 package of 3 29.10 / pack 650 - 950 Hp 176F8336 2 package of 3 29.10 / pack

P900 - P1M4 F Frame 1050 - 1550 Hp 176F8336 3 package of 3 29.10 / pack 1050 - 1350 Hp 176F8336 3 package of 3 29.10 / pack

Drive Power card fuse (F Frame = 1 pack / Rectifier & Inverter section)

P110 - P630 150 - 650 Hp 176F8440 1 package of 3 17.40 / pack 150 - 650 Hp 176F8440 1 package of 3 17.40 / pack

P630 - P900 F Frame 750 - 950 Hp 176F8440 3 package of 3 17.40 / pack 650 - 950 Hp 176F8440 3 package of 3 17.40 / pack

P900 - P1M4 F Frame 1050 - 1550 Hp 176F8440 4 package of 3 17.40 / pack 1050 - 1350 Hp 176F8440 4 package of 3 17.40 / pack

Drive Fan transformer fuse

P110 - P500 150 - 650 Hp 176F8440 1 package of 3 17.40 / pack 125 - 400 Hp 176F8440 1 package of 3 17.40 / pack

P560 - P630 600 - 650 Hp 176F8609 1 package of 3 50.30 / pack T7 500 - 600 Hp 176F8609 1 package of 3 50.30 / pack

P630 - P900 F Frame 750 - 950 Hp 176F8609 2 package of 3 50.30 / pack 650 - 950 Hp 176F8609 2 package of 3 50.30 / pack

P900 - P1M4 F Frame 1050 - 1550 Hp 176F8609 3 package of 3 50.30 / pack 1050 - 1350 Hp 176F8609 3 package of 3 50.30 / pack

Page 53: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

53 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575 V Bypass Main Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

575v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel =

Hp)

Variable torque HP or FLA @ 575 v

Ordering number Qty per drive List price

Constant torque high OL HP or FLA

@ 575 v

Ordering number Qty per drive List price

Bypass main fuse

H50 0.5 Hp 176U5277 3 14.90 each 0.5 Hp 176U5277 3 14.90 each

H75 0.75 Hp 176U5277 3 14.90 each 0.75 Hp 176U5277 3 14.90 each

001 1 Hp 176U5834 3 15.50 each 1 Hp 176U5834 3 15.50 each

1H5 1.5 Hp 34034900 3 51.30 each 1.5 Hp 34034900 3 51.30 each

002 2 Hp 176U5835 3 15.50 each 2 Hp 176U5835 3 15.50 each

003 3 Hp 34035000 3 15.50 each 3 Hp 34035000 3 15.50 each

005 5 Hp 34042500 3 15.50 each 5 Hp 34042500 3 15.50 each

7H5 7.5 Hp 34035300 3 15.50 each 7.5 Hp 34035300 3 15.50 each

010 10 Hp 34035400 3 15.50 each 10 Hp 34035400 3 15.50 each

015 15 Hp 34035500 3 15.50 each 15 Hp 34035500 3 15.50 each

020 20 Hp 34042600 3 18.70 each 20 Hp 34042600 3 18.70 each

025 25 Hp 34042700 3 18.70 each 25 Hp 34042700 3 18.70 each

030 30 Hp 34035700 3 20.60 each 30 Hp 34035700 3 20.60 each

040 40 Hp 34035800 3 18.70 each 40 Hp 34035800 3 18.70 each

050 50 Hp 176U5037 3 54.50 each 50 Hp 176U5037 3 54.50 each

060 60 Hp 34043000 3 47.60 each 60 Hp 34043000 3 47.60 each

075 75 Hp 34043100 3 74.20 each 75 Hp 34043100 3 74.20 each

100 100 Hp 34043200 3 68.70 each 100 Hp 34043200 3 68.70 each

125 125 Hp 34043400 3 79.20 each 125 Hp 34043400 3 79.20 each

150 150 Hp 176U5784 3 185.80 each 150 Hp 176U5784 3 185.80 each

200 200 Hp 34050000 3 141.70 each 200 Hp 34050000 3 141.70 each

250 250 Hp 34050100 3 225.00 each 250 Hp 34050100 3 225.00 each

300 300 Hp 34043700 3 225.00 each 300 Hp 34043700 3 225.00 each

350 350 Hp 176U5669 3 417.30 each 350 Hp 176U5669 3 417.30 each

Page 54: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

54 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575 V N1 / N12 Bypass or CMS Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

575v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @

575 v

Ordering number Qty per drive List price

Constant torque high OL HP or

FLA @ 575 v

Ordering number Qty per drive List price

UL / NEMA type 1 & 12 Bypass or CMS power supply primary fuse

All All Hp 612Z1291 3 5.20 each - - - -* NOTE: 20 amp fuse 612Z1291 replaces 4 amp fuse 612Z1184 originally supplied to improve ride-through of voltage spikes caused by switching the panel input to an emergency genenrator or by utilitily power factor correction switching

UL / NEMA type 1 & 12 Bypass or CMS transformer primary fuse

100 100 Hp 34046000 2 7.70 each 100 Hp 34046000 2 7.70 each

125 125 Hp 34046000 2 7.70 each 125 Hp 34046000 2 7.70 each

150 150 Hp 176U5633 2 7.90 each 150 Hp 176U5633 2 7.90 each

200 200 Hp 176U5633 2 7.90 each 200 Hp 176U5633 2 7.90 each

250 250 Hp 176U5633 2 7.90 each 250 Hp 176U5633 2 7.90 each

300 300 Hp 176U5633 2 7.90 each 300 Hp 176U5633 2 7.90 each

350 350 Hp 176U5633 2 7.90 each 350 Hp 176U5633 2 7.90 each

UL / NEMA type 1 & 12 Bypass or CMS transformer secondary fuse

100 100 Hp 34045500 1 3.80 each 100 Hp 34045500 1 3.80 each

125 125 Hp 34045500 1 3.80 each 125 Hp 34045500 1 3.80 each

150 150 Hp 176U5276 1 7.90 each 150 Hp 176U5276 1 7.90 each

200 200 Hp 176U5276 1 7.90 each 200 Hp 176U5276 1 7.90 each

250 250 Hp 176U5276 1 7.90 each 250 Hp 176U5276 1 7.90 each

300 300 Hp 176U5276 1 7.90 each 300 Hp 176U5276 1 7.90 each

350 350 Hp 176U5276 1 7.90 each 350 Hp 176U5276 1 7.90 each

Page 55: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

55 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575v HVAC FC102 / AQUA FC202 units Automation FC302 units

Drive Power size (Drive = kW, Panel

= Hp)

Variable torque HP or FLA @ 575 v

Ordering number Qty per drive List price

Constant torque high OL HP or FLA

@ 575 v

Ordering number Qty per drive List price

UL / NEMA type 1 & 12 Dual motor fuses

A 0.5 HP 176U5277 3 per motor 14.90 each 0.5 HP 176U5277 3 per motor 14.90 each

B 0.75 HP 176U5277 3 per motor 14.90 each 0.75 HP 176U5277 3 per motor 14.90 each

C 1.0 HP 176U5834 3 per motor 15.50 each 1.0 HP 176U5834 3 per motor 15.50 each

D 1.5 HP 34034900 3 per motor 51.30 each 1.5 HP 34034900 3 per motor 51.30 each

E 2.0 HP 176U5835 3 per motor 15.50 each 2.0 HP 176U5835 3 per motor 15.50 each

F 3.0 HP 34035000 3 per motor 15.50 each 3.0 HP 34035000 3 per motor 15.50 each

G 5.0 HP 34042500 3 per motor 15.50 each 5.0 HP 34042500 3 per motor 15.50 each

H 7.5 HP 34035300 3 per motor 15.50 each 7.5 HP 34035300 3 per motor 15.50 each

I 10 HP 34035400 3 per motor 15.50 each 10 HP 34035400 3 per motor 15.50 each

J 15 HP 34035500 3 per motor 15.50 each 15 HP 34035500 3 per motor 15.50 each

K 20 HP 34042600 3 per motor 18.70 each 20 HP 34042600 3 per motor 18.70 each

L 25 HP 34042700 3 per motor 18.70 each 25 HP 34042700 3 per motor 18.70 each

M 30 HP 34035700 3 per motor 20.60 each 30 HP 34035700 3 per motor 20.60 each

N 40 HP 34035800 3 per motor 18.70 each 40 HP 34035800 3 per motor 18.70 each

O 50 HP 176U5037 3 per motor 54.50 each 50 HP 176U5037 3 per motor 54.50 each

P 60 HP 34043000 3 per motor 47.60 each 60 HP 34043000 3 per motor 47.60 each

Q 75 HP 34043100 3 per motor 74.20 each 75 HP 34043100 3 per motor 74.20 each

R 100 HP 34043200 3 per motor 68.70 each 100 HP 34043200 3 per motor 68.70 each

S 125 HP 34043400 3 per motor 79.20 each 125 HP 34043400 3 per motor 79.20 each

T 150 HP 176U5784 3 per motor 185.80 each 150 HP 176U5784 3 per motor 185.80 each

U 200 HP 34050000 3 per motor 141.70 each 200 HP 34050000 3 per motor 141.70 each

V 250 HP 34050100 3 per motor 225.00 each 250 HP 34050100 3 per motor 225.00 each

W 300 HP 34043700 3 per motor 225.00 each 300 HP 34043700 3 per motor 225.00 each

Y 350 HP 176U5669 3 per motor 417.30 each 350 HP 176U5669 3 per motor 417.30 each

575 V Fuses N1 / N12 Dual Motor Fuses

Page 56: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

56 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

575 V Fuses

Fuses for the vertical bypass configurations >5 Hp @ 208 v and >15 Hp @ 460 or 600v are not included. Contact the factory for fuse identification and pricing.

N3R Bypass or CMS fuses

575v HVAC FC102 / AQUA FC202 units

Drive Power size (Drive = kW, Panel = Hp)

Variable torque HP or FLA @ 575 v Ordering number Qty per drive List price

UL/NEMA type 3R Bypass / CMS transformer primary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

All All Hp 176U5397 2 7.90 each

UL/NEMA type 3R Bypass / CMS transformer secondary fuse !NOTE; Fuses are different for units with both Bypass & CMS!

30 - 75 30 - 75 Hp 34053800 1 3.80 each

UL/NEMA type 3R fan and heater transformer primary fuse

All @ 208 volt All Hp @ 208 volt 176U5402 1 7.90 each

All @ 230 volt All Hp @ 230 volt 176U5401 1 7.90 each

N3R Dual Motor fuses

UL/NEMA type 3R Dual motor fuses

A 0.65 - 1.1A 176U5834 3 per motor 15.50 each

B 1.1 - 1.4A 176U5834 3 per motor 15.50 each

C 1.5 - 1.7A 176U5834 3 per motor 15.50 each

D 1.8 - 2.6A 34034900 3 per motor 51.30 each

E 2.7 - 4.0A 34035000 3 per motor 15.50 each

F 4.1 - 6.3A 34042500 3 per motor 15.50 each

G 6.4 - 8.5A 34035300 3 per motor 15.50 each

H 8.6 - 10.5A 34035300 3 per motor 15.50 each

I 10.6 - 14.4A 34035400 3 per motor 15.50 each

J 14.5 - 18.0A 176U5837 3 per motor 15.50 each

K 21.0 - 25.5A 34042600 3 per motor 18.70 each

L 25.6 - 32.0A 34035600 3 per motor 18.70 each

M 32.1 - 38.0A 34035700 3 per motor 20.60 each

N 38.1 - 42.0A 34035800 3 per motor 18.70 each

P 42.1 - 54.0A 34042800 3 per motor 47.60 each

Q 54.1 - 64.0A 34042900 3 per motor 54.50 each

R 64.1 - 82.0A 34049900 3 per motor 72.80 each

Page 57: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

57 06/30/11FUSES PL

VLT® Drive and Standard Panel Replacement Fuses

VLT® Drive Replacement Terminals Price List

Frame

Drive Type CT = FC 301 & 302 constant torque VT = FC102 & 202 variable torque

Enclosure type IP20 = protected chassis

IP21 = NEMA 1 IP55 = NEMA 12

IP66 = indoor NEMA 4

Part Description Part ordering number#

List price (each)

Terminal kits (replacement for hardware supplied with drive)

A1 - A3 CT w/ brake IP20, IP21 Accessory bag - A1, A2, A3 w/ Brake 130B0525 $78.60

A2, A3 VT IP20, IP21 Accessory bag - A2, A3 frame 130B1022 $30.00

A2, A3 VT, CT IP20 Accessory bag - A2, A3 Top Profibus Bus plate, IP20 130B0524 $38.50

A5 VT, CT IP55 Accessory bag - A5 frame (IP55) 130B1023 $30.00

B1 VT, CT IP21, IP55, IP66 Accessory bag - B1 130B2060 $30.00

B2 VT, CT IP21, IP55, IP66 Accessory bag - B2 130B2061 $30.00

B3 VT, CT IP20 Accessory bag - B3, IP20 130B0980 $32.80

B4 VT, CT IP20 Accessory bag - B4, IP20, w/ small cable clamps 130B1300 $53.40

B4 VT, CT IP20 Accessory bag - B4, IP20, w/ large cable clamps 130B1301 $60.20

C1 VT, CT IP21, IP55, IP66 Accessory bag - C1 130B0046 $46.20

C2 VT, CT IP21, IP55, IP66 Accessory bag - C2 130B0047 $48.90

C3 VT, CT IP20 Accessory bag - C3, IP20 130B0981 $52.80

C4 VT, CT IP20 Accessory bag - C4, IP20, w/ large cable clamps 130B0983 $52.70

C4 VT, CT IP20 Accessory bag - C4, IP20, w/ small cable clamps 130B0982 $53.40

Danfoss screwdriver (fits FC control terminals)

All All All FC Control terminal screwdriver 174N7424 $4.40

Standard control terminals (one set of FC control card terminals)

All All All Control Terminals set 130B0295 $52.20

Alternative control terminals (screw-down instead of spring tension)

All All All Control Terminals set, screw terminal 130B1116 $25.00

Bulk packages of replacement terminals

A2, A3 All All Terminal block for DC-link connection on A2/A3 frames 130B1064 $105.00

All All All 10 pack of 10 pole spring loaded connectors FC302 130B1073 $135.00

All CT All 10 pack of 8 pole spring loaded connectors FC301 130B1072 $105.00

All All All 10 pack of 6 pole spring loaded connectors FC301/302 130B1071 $70.00

All All All 10 pack of 3 pole spring loaded connectors RS485 port 130B1070 $40.00

All All All 10 pack of 3 pole spring loaded connectors Relay 01 130B1069 $45.00

All All All 10 pack of 3 pole spring loaded connectors Relay 02 130B1068 $45.00

All All IP20, IP21 10 pack of mains connectors IP20/21 enclosures 130B1067 $55.00

All All IP55 10 pack of mains connectors IP55 enclosures 130B1066 $100.00

All All All 10 pack of motor connectors 130B1065 $55.00

Page 58: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

58 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Products covered

PageVLT

MicroVLT

2800VLT

AQUA DriveMCD200

MCD500

AAFAHF

Applications and field service assistance • • • • • • 59Exchange warranty 2 – 5 year coverage • • • 59

Startup Optional on-site training • • • • • • 60

Factory depot repairs • • • • • 61DrivePro-tection Depot Repair Insurance 1.5 – 6 year coverage • • • 63

Enhanced on-site service warranty 2 – 6 year coverage • • • 65

Danfoss DriveProTM offers a comprehensive selection of startup and servicing programs that ensure your drive installation’s performance from date of shipment through the life of the application.

Prices and Multipliers

The DrivePro products and services described on the following pages are all at list price. Multipliers apply as follows:

• ExtendedWarrantyorStartup&TrainingServices ordered with a drive will use the same multiplier as the drive

• Startup&TrainingServicesorderedon demand (separately from the drive order) will use the standard VLT AQUA Drive multiplier, as applicable

• Repairandfieldsupportordersusethestandard DrivePro multiplier

Additional Service Options

PleasecallDanfossforaquoteonanyserviceoptions not listed in this book, including but not limited to:

• Post-warrantyservicecontracts

• Preventivemaintenancecontracts

• Equipmentmigrationcontracts

• Extendedservicewarrantycontractsfornon-drive products

• Repairsofotherproducts

• Sparedriveson-siteservicecontracts

• Drivelease-to-ownprograms

Page 59: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

59 06/30/11DPRO PL

DrivePro™ Professional Drive Support

DrivePro™ Applications & Field AssistanceWater / Wastewater DrivePro Service List Price - effective 1/1/11 DrivePro product multiplier applies to repair services

DrivePro™ Exchange WarrantyDrive order multiplier applies when purchased with drive

Emergency Shipping Services

A $300 handling fee will be added for emergency shipments performed outside of normal working hours (8:00 am to 5:00 pm or weekends). Additional charges will apply to cover shipping and delivery cost.

Field Service RatesHourly rates*

Product Applications

Support

Product Service and Training

SupportMonday – Friday 8:00 am to 5:00 pm $180 $120

Monday – Friday Before 8:00 am and after 5 pm 270 180

Saturday 8:00 am to 5:00 pm 270 180

Saturday Before 8:00 am or after 5:00 pm 360 240

Sunday and US Holidays 360 240

* Field Service pricing applies to locations in the U.S. or Canada. The minimum available field support is 4 hours of billable support in addition to travel and expense charges. Travel time is billed at 1/2 the applicable field service rate. Travel expenses (air fare, hotel, auto rental, fuel, parking tolls, etc.) are billed at cost.

Available for:

• VLT®MICRO

• VLT®2800

• MCD100&200SoftStarters

Exchange Warranty extends the product warranty beyond the standard period.

Coverage begins on the date of shipment and extends to the end of the contract period.

Total coverage from end of std warranty

Tier 2 year 3 year 4 year 5 year

Micro < 7.5 Hp VLT 2800 < 1.5 kW MCD 100 & 200 < 55kW

1EX124 EX136 EX148 EX160 Ordering number

$90 $120 $150 $180 List price per drive

Micro 10 - 30 Hp VLT 2800 2.2 - 7.5 kW MCD 100 & 200 > 55kW

2EX224 EX236 EX248 EX260 Ordering number

$140 $190 $250 $300 List price per drive

MCD 200 (75 – 110 kW)VLT 2800 > 7.5 kW 3

EX324 EX336 EX348 EX360 Ordering number$240 $350 $460 $570 List price per drive

Page 60: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

60 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Purchase type

Power range Pre Pay* On Demand** Pre Pay* or On Demand**

All VAC Frame1/2 Day 1/2 Day Full Day

4 4 8 Max hours onsite1 **** 1 **** 1 **** Max trips included

Allpowersizes All

SUPW01 SUDW01 SUFW01 Ordering number

$830 $890 $1,400

List price per service during standard business hours***

*Pre Pay = purchased with drive - invoiced at the time of drive shipment

**On demand = purchased after drive shipment from factory - invoiced at the time of service

*** Standard business hours = 8:00 AM - 5:00 PM Monday - Friday excluding holidays

**** Maximum 2 hour round trip

Additional services List Price

Product training by a DrivePro certified technician at time of start-up service during standard business hours***. Training includes basic product operating instructions and application specific drive programming.

$120 / hour

Additional trips (when service purchased is split over multiple days) $120 / hour

Non Standard business hours Start-up or Training Service

Monday - Friday before 8:00 AM or after 5:00 PM or Saturdays 8:00 AM - 5:00 PM LP x 1.5

Sundays, Holidays and Saturdays before 8:00 AM or after 5:00 PM LP x 2

DrivePro-tection — Start-up serviceWater/Wastewater DrivePro Service List Price - effective 1/1/11 Drive order multiplier applies when purchased with drive Standard Drive multiplier applies for on-demand purchases

Service terms

Start-upserviceisperformedbyaDanfossAuthorizedServicePartnerorganization.DriveProcertifiedtechnicianinspectsdrive&installation,programs the Danfoss product as needed for application and tests drive functions as allowed by customer & system readiness.

Danfoss reserves the right to bill at standard Danfoss onsite labor rates for time over the maximum and additional trips.

Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada.

Travel to other areas within the U.S. or Canada is available at the additional trip hourly rate plus overnight expenses.

This chart applies to All Danfoss Drive Products

Start-up readiness stipulation

Start-up service does not include product installation, wiring, technical support of system integrations such as PLC programming or serial communications system verification.

Wire terminations are to be completed but no power is to be applied to the drive prior to Danfoss Start-up service. Application of power prior to Start-up service may result in damage to the drive product. Repair of this type of damage is not included in the product warranty or startup service.

Page 61: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

61 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Factory Depot Repairs

Flat Rate price repairs excludes shippingRepairs for drives not listed:

• FC series A Frame, MICRO Drive, VLT 2800 Drive, FCM & FCD Drive repairs are not available

• FC series D, E & F frame, and MCD 500 repaired at hourly Service Depot Repair rates

Service Depot Repair RatesMonday - Friday 8:00 AM - 5:00 PM $100 / hr

Monday - Friday before 8:00 AM or after 5:00 PM $130 / hr

Saturday 8:00 AM - 5:00 PM $130 / hr

Saturday before 8:00 AM or after 5:00 PM $170 / hr

Sunday or US Holiday $170 / hr

Depot Service Expedite FeesSame day turnaround* $300

24 hour turnaround* $215

48 hour turnaround* $130

72 hour turnaround* $110

Factory Inspection FeesPART NO. LIST PRICE DRIVES COVERED

INSP-1 $85 FCM/FCD

INSP-2 $85 VLT MICRO

INSP-3 $85 VLT 2800

INSP-4 $165 All series 1- 10 HP

INSP-5 $235 All series 15-100 HP

INSP-6 $350 All series 125-300 HP

INSP-7 $175 All Soft Staters & AHF

*Expedited turnaround is available during normal M - F workdays. Turnaround time does not include product transit time. Products must be received by9:00AMtoqualifyforsamedayturnaround

Flat Rate Repair Pricing Variable torque models Constant torque models

Ordering number

Listprice

VLT 4000, VLT 6000, VLT 8000 VLT HVAC Drive, VLT AQUA VLT 5000, VLT 5000 FLUX VLT AutomationDrive

200-240V 360-460V 550-600V 200-240V 360-460V 550-600V 200-240V 360-460V 550-600V 200-240V 360-460V 550-600V

FFR-1 $320X002 X002 X002 5001 5001 5001

X003 X003 5002 5002

FFR-2 $370X003 X004 X004 5002 5003 5003

X004 X005 5003 5004 5004

FFR-3 $470

X005 X006 X006 5004 5005 5005

X006 X008 X008 5005 5006 5006

X008 P5K5 5006

FFR-4 $650X011 X011 X011 P7K5 5008 5008 5008 P5K5

X016 X016 P11K P11K 5011 5011

FFR-5 $850X016 X022 X022 P11K P15K P15K 5011 5016 5016 P7K5 P11K P11K

X022 P15K 5016 P11K

FFR-6 $1,070X027 X027 X027 P18K P18K P18K 5022 5022 5022 P15K P15K P15K

X032 P22K 5027 P18K

FFR-7 $1,170X032 X032 P22K P22K 5027 5027 P18K P18K

X042 X042 P30K P30K 5032 5032 P22K P22K

FFR-8 $1,280 X042 X052 X052 P30K P37K P37K 5032 5042 5042 P22K P30K P30K

FFR-9 $1,530 X052 X062 X062 P37K P45K P45K 5042 5052 5052 P30K P37K P37K

FFR-10 $1,630 X072 X072 P55K P55K 5062 5062 P45K P45K

FFR-11 $1,820 X062 X102 X102 P45K P75K P75K 5052 5072 5072 P37K P55K P55K

FFR-12 $1,940 X122 X122 P90K P90K 5102 5102 P75K P75K

FFR-13 $2,130 5122 5122 P90K P90K

Water / Wastewater DrivePro Service List Price - effective 1/1/11 DrivePro product multiplier applies to repair services Drive repairs and other services performed by Danfoss techicians at the Danfoss Drives North America facility.

Page 62: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

62 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Coverage Terms:DrivePro-tection w/ Start-up combines SU service for one drive with a product warranty upgrade by covering travel cost (maximum 2 hours round trip) to the customer site and coverage of accidental damage to the product after installation, including the following: ‘-Momentary line or load anomalies such as lightning strikes. ‘-Accidental collision after installation ‘-Temporary exposure to moisture or corrosives Danfoss reserves the right to deny coverage for failures due to product vandalism, miss-application, shipping or installation damage, chronic destructive site conditions or site catastrophes such as floods or fires.

Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss reserves the right to charge for Start-up service travel time over 2 hours

Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive

Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters)

DrivePro™ Startup Service with DrivePro-tection — Onsite Drive Insurance Contract Water/Wastewater DrivePro Service List Price - effective 1/1/11 Drive order multiplier applies when purchased with drive

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number DTSW118 DTSW124 DTSW136 DTSW148 DTSW160 DTSW172List price per drive $930 $970 $1,060 $1,140 $1,210 $1,290

5 - 20 15 - 40 BOrdering number DTSW218 DTSW224 DTSW236 DTSW248 DTSW260 DTSW272List price per drive $1,020 $1,100 $1,240 $1,380 $1,530 $1,670

25 - 60 50 - 125 COrdering number DTSW318 DTSW324 DTSW336 DTSW348 DTSW360 DTSW372List price per drive $1,230 $1,370 $1,660 $1,940 $2,220 $2,500

150 - 350 DOrdering number DTSW418 DTSW424 DTSW424 DTSW448 DTSW460 DTSW472List price per drive $1,570 $1,830 $2,350 $2,860 $3,390 $3,900

400 - 650 EOrdering number DTSW518 DTSW524 DTSW536 DTSW548 DTSW560 DTSW572List price per drive $2,830 $3,480 $4,800 $6,120 $7,420 $8,720

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number DTPS118 DTPS124 DTPS136 DTPS148 DTPS160 DTPS172List price per drive $980 $1,020 $1,130 $1,220 $1,320 $1,420

5 - 20 15 - 40 BOrdering number DTPS218 DTPS224 DTPS236 DTPS248 DTPS260 DTPS272List price per drive $1,090 $1,180 $1,350 $1,530 $1,700 $1,880

25 - 60 50 - 125 COrdering number DTPS318 DTPS324 DTPS336 DTPS348 DTPS360 DTPS372List price per drive $1,340 $1,510 $1,870 $2,220 $2,560 $2,900

150 - 350 DOrdering number DTPS418 DTPS424 DTPS436 DTPS448 DTPS460 DTPS472List price per drive $1,760 $2,080 $2,720 $3,350 $4,000 $4,630

400 - 650 EOrdering number DTPS518 DTPS524 DTPS536 DTPS548 DTPS560 DTPS572List price per drive $3,300 $4,110 $5,740 $7,360 $8,960 $10,560

Page 63: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

63 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Coverage Terms:DrivePro-tection upgrades the product warranty by covering travel cost to the customer site and coverage of accidental damage to the product after installation, including the following:

‘-Momentary line or load anomalies such as lightning strikes. ‘-Accidental collision after installation ‘-Temporary exposure to moisture or corrosives

Danfoss reserves the right to deny coverage for failures due to product vandalism, miss-application, shipping or installation damage, chronic destructive site conditions or site catastrophes such as floods or fires.

Coverage begins on the date of shipment and extends to the end of the contract period.

Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada.

Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive

Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters)

DrivePro-tection — Onsite Drive Insurance Contract Water/Wastewater DrivePro Service List Price - effective 1/1/11 Drive order multiplier applies when purchased with drive

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number DTW118 DTW124 DTW136 DTW148 DTW160 DTW172List price per drive $190 $230 $310 $390 $470 $540

5 - 20 15 - 40 BOrdering number DTW218 DTW224 DTW236 DTW248 DTW260 DTW272List price per drive $280 $350 $490 $640 $780 $920

25 - 60 50 - 125 COrdering number DTW318 DTW324 DTW336 DTW348 DTW360 DTW372List price per drive $480 $620 $910 $1,190 $1,470 $1,750

150 - 350 DOrdering number DTW418 DTW424 DTW436 DTW448 DTW460 DTW472List price per drive $820 $1,080 $1,600 $2,120 $2640 $3,160

400 - 650 EOrdering number DTW518 DTW524 DTW536 DTW548 DTW560 DTW572List price per drive $2,080 $2,730 $4,050 $5,370 $6,670 $7,970

700 - 1300 FOrdering number DTW618 DTW624 DTW636 DTW648 DTW660 DTW672List price per drive $4,000 $5,240 $7,740 $10,270 $12,710 $15,250

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 1.5 year 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number DTPW118 DTPW124 DTPW136 DTPW148 DTPW160 DTPW172List price per drive $230 $280 $380 $480 $570 $670

5 - 20 15 - 40 BOrdering number DTPW218 DTPW224 DTPW236 DTPW248 DTPW260 DTPW272List price per drive $340 $430 $600 $780 $960 $1,130

25 - 60 50 - 125 COrdering number DTPW318 DTPW324 DTPW336 DTPW348 DTPW360 DTPW372List price per drive $590 $760 $1,120 $1,470 $1,810 $2,160

150 - 350 DOrdering number DTPW418 DTPW424 DTPW436 DTPW448 DTPW460 DTPW472List price per drive $1,010 $1,330 $1,970 $2,600 $3,250 $3,880

400 - 650 EOrdering number DTPW518 DTPW524 DTPW536 DTPW548 DTPW560 DTPW572List price per drive $2,560 $3,360 $4,990 $6,610 $8,210 $9,810

700 - 1300 FOrdering number DTPW618 DTPW624 DTPW636 DTPW648 DTPW660 DTPW672List price per drive $4,920 $6,450 $9,520 $12,640 $15,640 $18,770

Page 64: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

64 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Coverage Terms:Enhanced Service Warranty with Start-up combines SU service for one drive with a product warranty upgrade by covering travel cost to the customer site.

Coverage begins on the date of shipment and extends to the end of the contract period.

Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada. Danfoss reserves the right to charge for Start-up service travel time over 2 hours

Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive

Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters)

DrivePro™ Startup with Enhanced On-Site Service WarrantyWater/Wastewater DrivePro Service List Price - effective 1/1/11 Drive order multiplier applies when purchased with drive

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number ESW124 ESW136 ESW148 ESW160 ESW172List price per drive $920 $990 $1,050 $1,110 $1,170

5 - 20 15 - 40 BOrdering number ESW224 ESW236 ESW248 ESW260 ESW272List price per drive $1,020 $1,130 $1,240 $1,350 $1,460

25 - 60 50 - 125 COrdering number ESW324 ESW336 ESW348 ESW360 ESW372List price per drive $1,230 $1,450 $1,670 $1,880 $2,100

150 - 350 DOrdering number ESW424 ES W436 ESW448 ESW460 ESW472List price per drive $1,580 $1,980 $2,380 $2,780 $3,180

400 - 650 EOrdering number ESW524 ESW536 ESW548 ESW560 ESW572List price per drive $2,850 $3,870 $4,880 $5,880 $6,880

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number ESPW124 ESPW136 ESPW148 ESPW160 ESPW172List price per drive $970 $1,060 $1,140 $1,210 $1,290

5 - 20 15 - 40 BOrdering number ESPW224 ESPW236 ESPW248 ESPW260 ESPW272List price per drive $1,100 $1,240 $1,380 $1,530 $1,670

25 - 60 50 - 125 COrdering number ESPW324 ESPW336 ESPW348 ESPW360 ESPW372List price per drive $1,370 $1,660 $1,940 $2,220 $2,500

150 - 350 DOrdering number ESPW424 ESPW436 ESPW448 ESPW460 ESPW472List price per drive $1830 $2,350 $2,860 $3,390 $3,900

400 - 650 EOrdering number ESPW524 ESPW536 ESPW548 ESPW560 ESPW572List price per drive $3,480 $4,800 $6,120 $7,420 $8,720

Page 65: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

65 06/30/11DPRO PL

DrivePro™ Professional Drive Support

Coverage Terms:Enhanced Service Warranty upgrades the product warranty by covering travel cost to the customer site.

Coverage begins on the date of shipment and extends to the end of the contract period.

Pricing applies to drives installed in the 48 adjacent states; Oahu, Hawaii; Anchorage, Alaska; and Canada.

Use this table for Engineered Drives Systems (EDS - drives & panel packages), Low Harmonic Drive (LHD), Active Front End Drive (AFE), 12 Pulse Drive

Use this table for VLT AQUA & VLT Automation Drive, MCD 500 Soft Starter, Advance Harmonic Filter (AHF), Advanced Active Filter (AAF), Standard panel options (bypass, motor selection & line or load filters)

Enhanced On-Site Service WarrantyWater/Wastewater DrivePro Service List Price - effective 1/1/11 Drive order multiplier applies when purchased with drive

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number EWW124 EWW136 EWW148 EWW160 EWW172List price per drive $170 $235 $295 $355 $415

5 - 20 15 - 40 BOrdering number EWW224 EWW236 EWW248 EWW260 EWW272List price per drive $265 $375 $485 $595 $705

25 - 60 50 - 125 COrdering number EWW324 EWW336 EWW348 EWW360 EWW372List price per drive $475 $700 $915 $1,130 $1,345

150 - 350 DOrdering number EWW424 EWW436 EWW448 EWW460 EWW472List price per drive $830 $1,230 $1,625 $2,030 $2,425

400 - 650 EOrdering number EWW524 EWW536 EWW548 EWW560 EWW572List price per drive $2,100 $3,115 $4,130 $5,130 $6,130

700 - 1300 FOrdering number EWW624 EWW636 EWW648 EWW660 EWW672List price per drive $4,030 $5,950 $7,900 $9,770 $11,730

HP Range (VT) Total coverage from date of shipment208 VAC 460 / 600 VAC Frame 2 year 3 year 4 year 5 year 6 year

1 - 3 1.5 - 10 AOrdering number EWPW124 EWPW136 EWPW148 EWPW160 EWPW172List price per drive $230 $310 $390 $470 $540

5 - 20 15 - 40 BOrdering number EWPW224 EWPW236 EWPW248 EWPW260 EWPW272List price per drive $350 $490 $640 $780 $920

25 - 60 50 - 125 COrdering number EWPW324 EWPW336 EWPW348 EWPW360 EWPW372List price per drive $620 $910 $1,190 $1,470 $1,750

150 - 350 DOrdering number EWPW424 EWPW436 EWPW448 EWPW460 EWPW472List price per drive $1,080 $1,600 $2,120 $2,640 $3,160

400 - 650 EOrdering number EWPW524 EWPW536 EWPW548 EWPW560 EWPW572List price per drive $2,730 $4,050 $5,370 $6,670 $7,970

700 - 1300 FOrdering number EWPW624 EWPW636 EWPW648 EWPW660 EWPW672List price per drive $5,240 $7,740 $10,270 $12,710 $15,250

Page 66: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

66 06/30/11TERMS PL

Unless otherwise provided in writing, Danfoss Inc.’s products are sold subject to the following conditions:

1. Subject to approval and continuance of approval of credit by Danfoss Inc., terms of payment are thirty days net from date of invoice (no cash discount), but if Danfoss Inc. does not approve credit to the Purchaser, or if at any time after any determined by Danfoss Inc. in its judgment to be or have become such as not to justify the continuance of such credit terms by Danfoss Inc. to the Purchaser, terms of payment shall be or become C.O.D., or immediate partial, or full advance payment, or a combination of the foregoing methods, all as Danfoss Inc. may then, or thereafter from time to time, elect and specify. All payments shall be in legal currency of the United States. Prices are subject to correction for error.

2. Danfoss Inc. shall not be deemed to have accepted an order until written confirmation of the order by Danfoss Inc. is sent to the prospective purchaser.

3. Danfoss Inc.’s products are delivered F.O.B. Danfoss Manufacturing site, freight prepaid and add, unless otherwise agreed to in writing. Method and route of shipment are at the discretion of Danfoss Inc. unless the purchaser supplies explicit instructions in writing.

4. Prices and products are subject to change without notice. The prices at which any order is accepted are subject to adjustment to the seller’s prices in effect at the time of shipment. Prices do not include sales, excise, municipal, state, or any other Government taxes.Allquotationsandconfirmationsaresubject to correction for stenographic or clerical error.

5. Packing is included in the price, and will not be credited if returned.

6. From the moment of delivery to the carrier, the purchaser shall bear all risks for the goods, and Danfoss Inc. shall not be responsible for damage incurred during transportation.

7. An order is accepted on the basis that Danfoss Inc.’s products are used or incorporated in systems of finished or semi-finished larger products within the continental limits of the United States. The products as received from Danfoss Inc. are not to be exported from the United States as such, unless otherwise noted.

8. Time of delivery is stated approximately. Danfoss Inc. does not undertake any responsibility for delays in consequenceof strikes, lockouts, labor disturbances or the like, extraordinary measures on the part of the government, hindrances to transportation including ice or other transport difficulties, delayed or defective delivery of materials ordered in due time, failing supply of electricity and similar

obstacles to production, fire or workshop accidents at own plant or at sub-suppliers, or other conditions over which Danfoss Inc. reasonable can be said to have no control.

9. Warranty Repair:

•ACVariableFrequencyDrives:18monthsfrom date of shipment.

•Productswithspecifiedshelflifestampedon packing excepted.

Danfoss agrees to repair, or replace, at the discretion of Danfoss, such products that on examination by Danfoss are found to be defective due to faulty manufacture, design, and/or defective materials. Expenses in connection with dismantling and mounting shall not be paid by Danfoss. If defects occur within the above mentioned periods, that product shall be forwarded to Danfoss, insurance and freight prepaid by customer. A description of the reason for returning the product shall be enclosed. Products repaired or replaced under warranty will be returned to the purchaser, freight prepaid by Danfoss. The warranty repairs are only offered provided that the terms of payment are observed and shall cease to be valid if the product is repaired or altered without the consent of Danfoss, or applied for purposes for which it is not designed, or installed and applied contrary to the instructions given by Danfoss.

10. THE WARRANTY GIVEN IN #9 IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ON THE PART OF DANFOSS INC. DANFOSS INC. DISCLAIMS ANY WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. DANFOSS INC. NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON, FIRM, OR CORPORATION TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THIS SALE. DANFOSS INC. SHALL NOT BE HELD RESPONSIBLE FOR DAMAGE TO PERSON OR PROPERTY, CONSEQUENTIAL LOSS, LOSS OF PROFIT, LOSSES ON GOODS IN STORE OR THE LIKE WHICH MIGHT ARISE OUT OF FAILURE OF THE EQUIPMENT DELIVERED, IRRESPECTIVE OF THE CAUSE (INCLUDING FAULTY MANUFACTURE).

All figures appearing in Danfoss Inc. catalogs instructions and directions, drawings, etc., as well as technical data and other information are approximate statements serving only as a guide to the purchaser, and do not form part of this contract, nor do they constitute this contract a sale by description. Danfoss Inc. is not responsible for instructions or technical assistance given verbally. Written information in reply to direct request isgivenontheunderstandingthattherequestdoes not contain incomplete or misleading information.

11. Danfoss Inc. shall defend any suit or proceeding brought against the Buyer as

General Conditions of Sale and Warrantyfar as the same is based on a claim that any apparatus of Danfoss’ design furnished hereunder or any part thereof, constitutes an infringement of any United States patent, if notified promptly in writing and given authority, information, and assistance (at Danfoss’ expense) for the defense of the same and if such alleged infringement is not the result of the design or other special requirements specified by theBuyer or the result of the application or use to which such apparatus is put by the Buyer or others. Danfoss Inc. will pay all damages and costs awarded to such suit or proceedings against the Buyer. In case such apparatus or part is in such suit held to infringe any such patent and the use thereof is enjoined. Danfoss shall, at its expense either, at its option, (a) obtain for the Buyer the right to continue using such apparatus or part, or (b) replace same with non-infringing apparatus, or (c) modify the same so that it becomes non-infringing, or (d) remove said apparatus and refund the purchase price and the transportation and installation costs thereof. The foregoing states the entire liability of Danfoss Inc. to the Buyer for patent infringement.

12. Any order to contract may be canceled by the Buyer prior to shipment only, if the product can be returned to Danfoss’ supplier for full credit, and the Buyer shall be responsible for all expenses incurred by Danfoss Inc. including freight. To the extent that goods covered by this agreement are manufactured by Danfoss, the Buyer will be responsible for payment of reasonable charges based upon expenses already incurred, commitments made by Danfoss Inc., and normal profit margins.

13. Any dispute of difference arising between the parties hereto as to the construction of this contract, or as to any matter arising out of or under this contract shall be resolved according to the laws of the State of Illinois.

14. Danfoss Inc. reserves the right to decide whether any dispute or difference arising out of or under this contract shall be referred to arbitration, or shall be resolved by legal action. If Danfoss Inc. decides that the dispute or difference shall be referred to arbitration, the parties agree to submit to the award to be made by an arbitration court appointed in accordance with the Rules of Conciliation and Arbitration of the International Chamber of Commerce.

Page 67: Water/Wastewater/Irrigation Price List - TLP Solutions · 2015-12-10 · Danfoss will select a broker for Canadian shipments. As an alternative, customers may elect to designate a

© Copyright 2011 by Danfoss 06/11

Danfoss can accept no responsibility for possible errors in catalogs, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also appliestoproductsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecificationsalreadyagreed.Alltrademarksinthis material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

175R5515

Danfoss VLT Drives8800 W. Bradley Rd.Milwaukee, WI 53224, USAPhone: 1.800.621.8806 1.414.355.8800Fax: 1.414.355.6117

DrivePro™ Profession Drives Support minimizesdowntimeexpenseandenablesyourpersonneltofocus on core business activities

Onsite Service Warranty extends the standard parts and repair labor warranty up to 6 years from date of factory shipment and enhances support by including travel expense coverage from day one. Onsite coverage is available throughout the continental United States and Canada, Oahu Hawaii and Anchorage Alaska.Repairsandreplacementsarecompletedbyfactorycertifiedtechniciansutilizingoriginalequipmentparts.

DrivePro-tection provides an even greater level of customer security by covering accidental damage to the drive in addition to coverage of normal product wear and defects in material or workmanship. Coverage includes lightning strikes, exposure to moisture or corrosives and collision damage after delivery. Like all other DrivePro coverage programs, Danfoss reserves the right to deny coverage due to shipping damage, product misapplication, vandalism, chronic environmental issues or facility disaster.

DrivePro Services provide the most complete drives support coverage available. Factory direct technical support is available via phone 24/7. Start-up and preventative maintenance services by factory certified technicians are available. Drive repair service at the North America VLT® Drives factory is also available. Contact your sales representative or the Danfoss DrivePro sales team for more information.

www.danfossdrives.com

Danfoss VLT Drives4401 N. Bell School Rd.Loves Park, IL, 61111, USAPhone: 1.800.432.6367 1.815.639.8600Fax: 1.815.639.8002

EnVisioneering