Page 1: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Water Treatment >>>

Core Business B

Page 2: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Siu Ho Wan Backup Telemetry SystemDavenham Engineering Limited

• Use Allen Bradley PLC 5 w/ControlNet capability (~300 I/O)

• Provide the newest available communication media - ControlNet.

• Provide the backup telemetry system for monitoring the water level in the remote stations.stations.

• Three remote stations communicate with the main PLC processor through leased line modems, and then via ControlNet back to the control room.

• Operators are able to read the data through the SCADA system that we designed.

Copyright © Lunar Technology Limited , 2013

Page 3: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Au Tau SCADA system Y2K upgradeDavenham Engineering Limited

• Use Allen Bradley PLC 5 processor (~250 I/O)

• Provide a new SCADA system to replace their existing old SCADA system in order to be Y2K compliant.

• Provide operator workstation which is Y2K compliant as well.

• Provide a programming tool in order for operators to modify the ladder logic as per required.

Copyright © Lunar Technology Limited , 2013

Page 4: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Pak Kong Water Treatment PlantDavenham Engineering Limited

• Use Allen Bradley SLC 500 processor (~350 I/O)

• Using the Y2K compliance solution to replace the existing system and reduce the process time.

• Replace their existing equipment with the Allen Bradley solution.with the Allen Bradley solution.

• Interface with the local PID controller and timer, which enable the operator use the external device to control the flow and time for the filter process.

Copyright © Lunar Technology Limited , 2013

Page 5: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Yau Kom Tau Treatment Works Stage I&IIDavenham Engineering Limited

• Use Hot Standby Allen Bradley PLC 5, SLC504 Processor, DH+ Network (~ 1300 I/O)

• By using hot standby PLCs to ensure the plant to run in non-stop operation.

• Using the Y2K compliance solution to replace the existing system and reduce the process time.

• Replace their existing equipment with the Allen Bradley solution.

• Interface with the local PID controller and timer, which enable the operator use the external device to control the flow and time for the filter process.

Copyright © Lunar Technology Limited , 2013

Page 6: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Tsuen Wan, Tsing Yi 1 to 4 Telemetry SystemDavenham Engineering Limited

• Use Allen Bradley PLC 5 (~300 I/O)

• Provide the telemetry system for remote control of the 4 outstations valves on/off control.

• Provide the telemetry system for monitoring the water level in the remote stations.

• Four remote stations communicate with the main PLC processor through leased line modems, and then via DH+ back to the control room.

• Operators are able to read the data through the Realflex SCADA system

Copyright © Lunar Technology Limited , 2013

Page 7: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Discovery Bay Pure Water Treatment PlantABB Industrial and Building Systems Ltd.

• Use Hot Standby Allen Bradley PLC5 CPU w/ControlNet Network (~500 I/O)

• Use the open architecture ControlNet as the communication backbone.

• Provide fast data communication -5Mbit/second with true redundancy media.

• Provide monitoring and controls for the • Provide monitoring and controls for the reservoir signal and alarm status.

• Provide SCADA mimic for monitoring in PanelView by telephone line signal.

Copyright © Lunar Technology Limited , 2013

Page 8: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Tian-Ji Samsung Engineering LimitedU.S. Filter

• Use Mitsubishi PLC processor (~700 I/O)

• Pure Water Treatment process for Tian-Ji area.

• Provide the Control Console for the Central Control Room.

• The Treatment processor can run • The Treatment processor can run automatically with monitoring from MMI package.

• Provide Moasic Tiles Mimic to indicate different equipment.

• Provide PLC/SCADA programming, installation and T&C for the pure water treatment plant.

Copyright © Lunar Technology Limited , 2013

Page 9: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

• Design, Supply, Delivery, Installation, T&C of all equipment and all necessary ancillaries for PLC and SCADA system.

• There are 3 Pumping Stations:(a) The Irrigation Water Pumping

Infrastructure for Penny’s Bay Development

– Mechanical and Electrical Works in Irrigation

Pumping StationsContract No. CV/2000/09

(a) The Irrigation Water Pumping Station (IPS) – Located in the Utilities Yard of the Penny’s Bay Development Area

(b) The Irrigation Booster Pumping Station – Located adjacent to the CLP Power Station at the Penny’s Bay Development Area

(c) The Yam O Landscape Irrigation Pumping Station – Located adjacent to the Yam O Sewage Pumping Station

Copyright © Lunar Technology Limited , 2013

Page 10: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Infrastructure for Penny’s Bay Development

– Mechanical and Electrical Works in Irrigation

Pumping StationsContract No. CV/2000/09

Copyright © Lunar Technology Limited , 2013

Page 11: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Island LabMaintenance ServiceHK Water Supply Department

• Use Siemens S7-300 and Allen-Bradley SLC-503 PLC

• Modified existing Wonderware Intouch Water Quality Monitoring System

• Implemented a MegaLink network to connect five SCADA systems in various remote WSD locations remote WSD locations

• Re-programmed all existing Siemens & WQMS computers; T&C to replace the existing SCADA system.

Copyright © Lunar Technology Limited , 2013

Page 12: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Replacement of Monitoring & Control Equipment for

Filters at Sheung Shui Water Treatment WorksContract No.: WSD/ST 450/06HK Water Supply Department

• Use Allen-Bradley SLC-505 PLC & Intouch software

• Replace & upgrade existing PLC & control panels

• Monitor & control treatment plants, network management, collect & store operating information

• Implement a fast Ethernet (100 Mbps) fiber optic redundant network

Copyright © Lunar Technology Limited , 2013

Page 13: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

12/WSD/05 – Datac GPRS RTU •Davenham Engineering Limited

� GPRS Back up modem Remote Terminal Units

� In case the communication of the main RTU fails due to poor weather or hardware failure, the backup or hardware failure, the backup system provides the essential Telemetry signal to control centre for back up monitoring and control

Copyright © Lunar Technology Limited , 2013

Page 14: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

� This project involves using Allen Bradleys SLC processors to monitor and control various systems that were previously controlled by relay logics.

� Control systems include:� Stage 1 Filters (10 sets) –

Control and monitoring� Stage 2 Filters (12 sets) –

ST450 Sheung Shui Water Treatment Works PLC and

SCADA systemDavenham Engineering Limited

� Stage 2 Filters (12 sets) –Control and monitoring

� Wash Water Recovery System 1 (3 tanks) – Control and monitoring

� Clarifier system (4 tanks) –Control and monitoring

� Sludge Plant – Control and monitoring

� Chemical system – Monitoring only

Copyright © Lunar Technology Limited , 2013

Page 15: Water Treatment >>> - grouplunar.com · communication media ... • Use Hot Standby Allen Bradley PLC 5, ... • Modified existing Wonderware Intouch Water Quality Monitoring System

Replacement of control & monitoring system of

Ma On Shan Water Treatment WorksRyoden Engineering Limited

� Use Allen-Bradley PLC and software to replace the Bailey DCS system� 12 Set SLC system is used

to control and monitoring the Plant operation.the Plant operation.

Copyright © Lunar Technology Limited , 2013