water purifying system -...
TRANSCRIPT
295 East Corporate Place • Suite 100 • Chandler, AZ 85225
Toll Free: 1.800.621.5886 • Phone: 480.893.7607 • Fax: 480.753.3397
[email protected] • www.1Paramount.com
004-027-8780-00 REV122010 US Patent Pending
MADE IN USA
WATER PURIFYING SYSTEMINSTALLATION MANUAL
EC
O FRIEND
LY
PA
RA
MOUNT CERTI
FIE
D
2
®2008, Paramount Pool and Spa Systems
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS: READ COMPLETELYBEFORE PROCEEDING WITH INSTALLATION. SAVE THESEINSTRUCTIONS
When using this electrical equipment, basic safety precautions shouldalways be followed, including the following:
CAUTION: READ AND FOLLOW ALL INSTRUCTIONS
WARNING:
• Follow all applicable electrical codes.
• A qualified licensed electrician should perform electricalhookup.
• Turn off power at main source before making any electricalconnections or servicing the unit.
• Use only liquid-tight flexible nonmetallic conduit for electricalconnections.
• A terminal marked G is located inside the supply terminalcompartment. To reduce the risk of electric shock, thisterminal must be connected to the grounding means providedin the electrical supply service panel with a continuous copperwire equivalent in size to the circuit conductors supplying thisequipment.
• At least one lug marked “BONDING LUG” provided on theexternal surface of the unit. To reduce the risk of electric
3
For technical assistance call 1.800.621.5886 or contact your regional representative
shock, connect the local common bond grid in the area of thepool or spa to this terminal with an insulated or bare copperconductor not smaller than 6 AWG.
WARNING:
• ALWAYS wear safety glasses when using power equipmentduring the installation process.
• Install at least 5 ft from pool or spa water using nonmetallicplumbing. Mount ozone generator near pool equipment atleast one (1) foot above maximum water level to preventwater from contacting electrical equipment. Install inaccordance with the installation instructions.
• Short-term inhalation of high concentrations of ozone andlong-term inhalation of low concentrations of ozone gas cancause serious harmful physiological affects. Do not inhale gasproduced by this unit. If installed in an enclosed space makesure to account for adequate ventilation.
• UV LIGHT PRODUCED BY THIS UNIT IS HARMFUL TOTHE EYES AND MAY CAUSE BLINDNESS. DO NOT LOOKDIRECTLY AT A LIT BULB!
NOTICE TO OWNER:
• Save these instructions and deliver to pool owner wheninstallation is complete.
SAFETY INSTRUCTIONS (CONT.)
4
For technical assistance call 1.800.621.5886 or contact your regional representative
WHAT IS OZONE AND HOW DOES IT WORK
• Ozone is created from oxygen using a simple yet powerful system of UV bulbs,to be used as a pure shock (oxidizer) for the swimming pool.
• Ozone is injected into the pool water using the Clear O3® suction injectionsystem, where the ozone enriched air is mixed with the water going into thepool circulation pump. This creates a dynamic environment that best mixes theair and water at high pressure as it is sent into the filter
• Once in the water, the ozone breaks down materials such as ammonia, oils, andother non-living waste that are detrimental to chlorine's function in the pool.This occurs between the pump and filter and also in the filter. Chlorine is in a group of the least stable elements and must becombined with another material to become stable. In swimming pools, thisprocess creates the formation of combined chlorines, like chloramines, whichdo not sanitize and have adverse effects on human skin. Use of ozone allowsthe chlorine to work primarily as a water disinfectant.
• Pool water treatment can be broken down into three primary categories:
1. Disinfectant- The killing of living organisms (virus, bacteria, algae). Thisconsumes only 10-20% of the chlorine normally placed in a pool.
2. Oxidation- The removal of non-living waste from pool water. This consumes upto 70% of the chlorine placed in standard treated pools
3. Residual- The remaining, measurable sanitizer is left in the pool as a safety net to maintain the water quality until it is broughtthrough the pool equipment again. Usually less than 10% of the chlorineoriginally placed in a pool is left over as residual.
Installing a Clear O3® Water Purification system will reduce the amount ofchlorine needed to maintain a pool by up to70%.
The benefits of using ozone include:• Fewer chemicals to maintain the pool.• Less work to maintain the pool water.• More enjoyable water, being treated similar to bottled water.• Longer filter cycles, and increased life for the salt chlorinator cells (if present).
TO COMPLETE INSTALLATION YOU WILL NEED THE FOL-LOWING ITEMS (NOT INCLUDED)
(1) Six (6) feet 1/2” non-metallic conduit outdoor rated.
(1) 1/2" conduit compression fitting.
5
For technical assistance call 1.800.621.5886 or contact your regional representative
SELECTING LOCATION & MOUNTING UNIT
1. Select a location on a wall near the pool equipment or insert posts into theground, which will be used to hang unit. The Clear O3® unit should be at leastone (1) foot above maximum water level, and for extra safety the unit shouldbe mounted higher than the filter. The unit should be within five (5) feet of anelectrical source, and within nine (9) feet of plumbing connection. A solidsurface is necessary to mount unit. Mounting brackets are horizontallyadjustable to line up with hard points on the mounting surface. The unit mustbe mounted horizontally and level on the wall. Electrical connections shouldbe facing downward.
2. Use provided screws and plastic wall inserts or poles and pole mount clamps (not included) depending on installationsurface available.
3. Four (4) mountingbrackets areincluded (two for thetop slot and two forthe bottom slot.
4. Install anchors andscrews in desiredlocation for the tophangers. They mustbe no further apart than twelve (12) inches. Do not tighten screws all the way.(Fig. 1)
5. Hang the Clear O3® from the two top brackets by sliding the keyhole slotsover the screws.
Fig. 1:
12" Maximum
6. Mark the location for the two bottom brackets. (Fig. 2)
7. Remove the Clear O3® from the wall and install the wall anchors.
8. Place the Clear O3® unit back on the screws and line up the two lowerbrackets with the wall anchors. (Fig. 3)
9. Install the bottom two screws and tighten all screws.
SELECTING LOCATION & MOUNTING UNIT
6
For technical assistance call 1.800.621.5886 or contact your regional representative
Fig. 3:
Fig. 2:
MAKING ELECTRICAL CONNECTIONS
7
For technical assistance call 1.800.621.5886 or contact your regional representative
Fig. 4: 120 Vac 50-60 Hz 0.8A
BLACK
GREEN
WHITE
PWR
GND
NEG PWR LINE 2
GND
PWR LINE 1
WHITE
GREEN
BLACK
230 Vac 50-60 Hz 0.38A
OUTPUT
30-60 Vac 700mA - 800mACLASS P, TYPE 1, RATING: A"RS" ELECTRONIC BALLAST
GREEN
WIRE NUTS
LAMP2X RED
2X BLUE
SIDE OF BALLAST
INPUTS
BLACK
BLACK
GREEN
WHITE
WHITEBLACK
WHITE
WARNING:Turn off power at main source before making any electrical connections or servicing the unit.
1. A licensed electrician should make all electrical connections. Makesure the unit is grounded by connecting to the pool equipments bondwire to comply with local electrical codes. See wiring diagram (Fig. 4).
2. Turn off power to the filtration system pump at the circuit breaker.
3. Install an approved seal tight flex conduit (not included) rated foroutdoor use between the Clear O3® unit and filtration system pumptime clock with the wires running inside (Fig. 5A & 5B). Electricalconnections should be facing downward.
4. Connect green ground wire to the time clock ground bar (Fig. 6A). TheClear O3® unit is set to 240VAC to be connected to the load side (Fig.6B) of the filtration pump time clock. The ballast may be switched to120VAC if needed (Fig. 7). See wiring diagram (Fig. 4). (Go to page21-23 for complete instructions on changing the ballast setting)
MAKING ELECTRICAL CONNECTIONS (CONT.)
8
For technical assistance call 1.800.621.5886 or contact your regional representative
Fig. 5A Fig. 5B
Fig. 6BFig. 6A
Fig. 7
Ground Lug
MAKING ELECTRICAL CONNECTIONS (CONT.)
9
For technical assistance call 1.800.621.5886 or contact your regional representative
The Clear O3® shouldrun with the filter pumpas the filter pumpcreates the air drawthrough the unit neededto create ozone. Do notset the Clear O3® to runwhen the filter pump isoff and not pulling airthrough the unit.
5. Use external ground lugto connect the Clear O3®
to the pool pump groundbond. (Fig. 8)
6. Turn on power to filtrationsystem pump. Check glowtube on the left front of theClear O3®. A light blue lightindicates lamp is lit and theunit should be producingozone. (Fig. 9)
Fig. 9
Fig. 8
Ground Lug
Light Blue Glow Tube
WARNING:UV light produced by this unit is harmful to theeyes and may cause blindness! Do not lookdirectly at a lit bulb!
10
For technical assistance call 1.800.621.5886 or contact your regional representative
MAKING PLUMBING CONNECTIONS
1. Turn off power to the filtration system pump at the circuitbreaker.
2. Pump strainer pot installation: (Fig. 10)
2.1 Check pump elevationabove water level. Refer to(Chart 1) for proper checkvalve selection. The 0.5 lbvalve comes standard withClear O3® and others areavailable to orderseperately.
2.2 Remove strainer pot plug. Ifthere is an O-Ring on plugtake O-Ring off of pot plugand slide over threaded endof check valve.
2.3 Wrap the check valve fourtimes with teflon tape andinstall into the strainer potplug-hole. Add more tapeif valve does not seal.(Fig. 11)
Fig. 10
Fig. 11
Chart 1
Pump Elevation Above Water Level Check Valve Rating
1’ (30cm) 0.5 lb
2’ (60cm) 1.5 lb
4’ (120cm) 3.0 lb
5’ (150cm) 4.0 lb
2.4 Install the combinationneedle valve flow meter onthe bottom of the ClearO3® unit. (Fig. 12)
2.5 Install 3/8 OD x 1/4 IDtubing to compression endof check valve. (Fig. 13)
3. Pre-pump standpipeinstallation: (Fig. 14A & 13)
3.1 Cut cap off standpipe.
3.2 Glue a 3/4" elbow and a3/4" x 1/4" NPTreducer bushing on endof standpipe.
3.3 Install the threaded endof the check valveincluded in the reducer bushing.
3.4 Install 3/8 OD x 1/4ID tubing to barbedend of check valve. (Fig. 13)
MAKING PLUMBING CONNECTIONS (CONT.)
11
For technical assistance call 1.800.621.5886 or contact your regional representative
Fig. 12
Fig. 14A NOT TO SCALE
WATER LINE
2" PIPE
3/4" PIPE 3/4" PIPE
WATER LINE
2" PIPE
3/4" PIPE
Fig. 13
WATER LINE
TO SKIMMER
TO MDX
CLEAR O3
3-WAY VALVE
2-WAY VALVE
CHECK VALVE
*NOT TO SCALE*2-WAY VALVE
3/4" PIPE2" PIPE
WATER LINECLEAR O3
CHECK VALVE
MAKING PLUMBING CONNECTIONS (CONT.)
12
For technical assistance call 1.800.621.5886 or contact your regional representative
4. OPTIONAL SUBMERGED EQUIPMENT INSTALLATION (Fig. 14B)
To complete this installation option you will need a two way valvenot included.
4.1 Install the two way valve on the inlet pipe to the pump suction.(before the standpipe if installed)
4.2 Make all other connections before the two way valve.
4.3 Make tubing connections to the pump pot or standpipe as instandard pump above water level installation.
4.4 Start the pump with the valve fully open.
4.5 Note the filter pressure. Then close the valve slightly until thepressure on the filter drops two or three psi.
4.6 Go to setting theairflow on page 16to finish settingairflow.
The slightrestriction thiscreates on thepump is the sameas if it was set atapproximately onefoot above waterlevel and allows thepump to draw air inat the pump pot orstandpipe.
(Fig. 14B)
Fig. 14B
MAKING PLUMBING CONNECTIONS (CONT.)
13
For technical assistance call 1.800.621.5886 or contact your regional representative
5. Lay the 3/8 tubing alongdesired route to thecompression fitting on thecombination needle valveflow meter on the Clear O3®
unit.
6. Connect the tubing to thecompression fitting. (Fig. 15)
7. Use the provided wires tiesto tie the loose tubing to theconduit or plumbing. (Fig. 16)
Fig. 15
Fig. 16
OPTIONAL SUBMERGED EQUIPMENT INSTALL.
14
For technical assistance call 1.800.621.5886 or contact your regional representative
New Installation using Paramount venturiinstallation kit.
TO COMPLETE THIS INSTALLATION YOUWILL NEED THE FOLLOWING ITEMS
(NOT INCLUDED)(2) 2” X 2” X ¾” SLIP TEE (1) ¾” X ¾” UNIONBALL VALVE (2) 2” VALVES ¾” FITTINGSAND PIPE (2) ¾” UNIONS NOTE: ¾” PLUMBING CAN BE 2” IF NEEDEDFOR STRENGTH
1. Install two ea. 2" inch valves, and twoeach 2 X 2 by ¾ inch tees. One valveand one tee on the suction side of thepump and one tee and valve on thereturn side of the pump (before theheater). (Fig. 17)
2. Plumb ¾ inch PVC from pressure sidetee into a union ball valve. (Fig. 18A)
3. Plumb ¾” inch PVC from the ball valveinto the inlet side of the venturi(coming from the return line after thefilter before the heater if it has one.(Fig. 18B)
4. Plumb ¾” inch PVC from the suctionside tee to a ball valve and union andthen into the outlet side of the venturi.Note the venturi must be level and theremovable for cleaning. The flowarrow on the venturi must point toshow the flow to the suction side ofthe pump. (Fig. 18B)
Fig. 17
Fig. 18A
Fig. 18B
5. Install the 3/8” OD x ¼ ID tubing onthe barbed end of the venturi, withthe check valve installed in-line. Notethe correct direction of flow throughthe check valve. (Fig. 19A & 19B)
6. Connect the tubing to thecompression fitting. (Fig. 20)
7. Connect the compression fitting tothe flow meter. (Fig 21)
OPTIONAL SUBMERGED EQUIP. INSTALL.(CONT.)
15
For technical assistance call 1.800.621.5886 or contact your regional representative
Fig. 19
Fig. 20 Fig. 21
Fig. 19B
SETTING AIR FLOW
16
For technical assistance call 1.800.621.5886 or contact your regional representative
1. Clean filter and pump basket before setting airflow.
2. Turn the knob on the needle valve/flow meter clockwise to closevalve completely.
3. Turn the power on to the pump
4. Turn the knob on the needle valve/flow meter counter clockwise untilthe ball reads in the middle of the two lines on the flow meter. (Fig.22)
NOTE: IF THE PUMP THAT THE CLEAR 03® UNIT IS INSTALLED ONIS A PUMP RUNNING A PARAMOUNT IN-FLOOR SYSTEM, lock thewater valve on pause when the valve is switching ports andtherefore at it’s maximum flow (the pause control is located on topof the Paramount water valve). Set the flow meter so the ball is onthe upper line of the Ideal range.
NOTE: WHEN USING MULTIPLE SPEED PUMPS, SET THE FLOWMETER WITH THE PUMP RUNNING ON THE HIGHEST SPEEDTHAT WILL BE USED.
Fig. 22
EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS (OPTIONAL)
17
For technical assistance call 1.800.621.5886 or contact your regional representative
Sometimes the internalair bleed on the filter isnot sufficient to handlethe extra air in the systemwith an ozonator installed.An External Safety AirBleed Kit (006-402-3872-00) (Fig. 23) forin-ground swimmingpools is available toremove excess air fromthe filter and send itdownstream (up to 15')past all equipment. Afterinstalling always test per instructions that air is vented from the filter whenthe pump is running. You must install an external air bleed if the filter is old,does not have an internal air bleed, there is a solar system on the pool orthere is a robotic pressure side cleaner.
Mounting Instructions
1. Turn the power off tothe pump.
2. Remove the pressuregauge from the filter.
3. Install the nipple into oneend of the brass tee.
4. Install the pressuregauge by threading intothe other end of thebrass tee supplied.
5. Install the tubingcompression fitting bythreading into the side of the brass tee.
External Safety Air Bleed Kit
FromPump
Filter Heater
Biostat/Biocide
Chlorinator
Return Line
4
321
Installation of External Safety Air Bleed Kit
Fig. 23
Fig. 24
EXTERNAL SAFETY AIR BLEED KIT INSTRUCTIONS (OPTIONAL) (CONT.)
18
For technical assistance call 1.800.621.5886 or contact your regional representative
6. Install the tee assembly by threading into the hole where youremoved the pressure gauge (Fig. 24 Pg. 17).
7. Insert one end of the tubing into the compression fitting (Fig. 24 Pg. 17).8. Turn the power on to the pump and check that air is coming from theother end of the tubing.
9. Turn the power off to the pump.10. Pick a spot on the return pipe downstream of all other devices
(heater, chlorinator, pressure cleaner, etc.) 11. Drill a 7/16" hole through the return pipe at the location
selected. 12. Install the saddle clamp with the fitting over the hole.
Make sure the gasket is in place between the fitting and the pipe.(Fig. 24 Pg. 17)
13. Lay the tubing along the return pipe to the saddle clamp fitting andcut off excess length.
14. Connect the end of the tubing to the compression fitting on thesaddle clamp (Fig. 24 Pg. 17). The tubing can be secured to thepipe using cable ties (not included).
NOTE:Ozone production from direct UV light will decline over time. UV bulbscontinue to illuminate after they stop producing an effective level of ozoneto clean your pool water. To make sure your pool continues to receive all thebenefits of ozone, Paramount recommends that you replace your bulb everythree (3) years.
WARNING:• Turn off power at main source before making any electricalconnections or servicing the unit.
• UV light produced by this unit is harmful to the eyes andmay cause blindness! Do not look directly at a lit bulb!
BULB REPLACEMENT
BULB REPLACEMENT (CONT.)
19
For technical assistance call 1.800.621.5886 or contact your regional representative
1. Turn the power off tofiltration system pumpat circuit breaker.
2. Remove three screwsin left end side caplabeled “electricalconnections”. (Fig.25)
3. Remove side cap.(Fig. 26)
4. Grasp light bulb plugand pull light out about oneinch. (Fig. 27)
Fig. 25
Fig. 26
Fig. 27
BULB REPLACEMENT (CONT.)
20
For technical assistance call 1.800.621.5886 or contact your regional representative
5. Remove plug fromlight bulb. (Fig. 28)
6. Pull light bulb freefrom Clear O3®
unit. (Fig. 29)
7. Make sure gasket isin place onreplacement lightbulb.
8. Align with key andslide into hole untilbulb seats firmlyand completely intounit. (Fig. 30)
9. Press plug ontolight bulb.
10. Replace side capand three screws.
11. Turn on power tofiltration systempump.
12. Check glow tubeon the left front ofthe Clear O3®. Alight blue lightindicates lamp is litand the unit shouldbe producingozone.
Fig. 29
Fig. 30
Fig. 28
TROUBLESHOOTING & SERVICE
21
For technical assistance call 1.800.621.5886 or contact your regional representative
ISSUE SOLUTION
1. No air bubbles Clean filter then adjust entering system or pool airflow needle valve.
2. Filter empties and Replace check valve pump loses prime fitting at strainer pot.
3. Light bulb does not light Check power to Clear O3®, then replace bulb.
1. Turn off the power at the breaker andremove the unit from wall mounting.
2. With a Phillips screwdriver, remove thethree (3) screws in the left end side cap,labeled electrical connections.(Fig. 31)
3. Remove side cap by pulling out from theend of the unit.
4. Inside the open electrical housing, findthe light bulb plug and pull it out aboutone inch. (Fig. 32)
CONVERTING BALLAST VOLTAGE TO ALTERNATE SETTING
Fig. 31
Fig. 32
22
For technical assistance call 1.800.621.5886 or contact your regional representative
CONVERTING BALLAST VOLTAGE TO ALTERNATE SETTING(CONT.)
5. While holding the bulb, wiggle the plug toloosen from the bulb and pull it free fromlight bulb.(Fig. 33)
6. Pull the light bulb from the unit.
7. With a Phillips screwdriver, remove thetwo (2) screws inside the electricalhousing next to the light bulb hole thatconnect the electrical housing to thealuminum housing.(Fig. 34)
8. While holding the aluminum housing,remove the electrical housing by pullingfrom the end of the unit. (Wires do notneed to be disconnected.)
9. Inside the back cavity of the aluminumhousing you will see the ballast and anut holding the two groundwires in place.(Fig. 35)
Fig. 33
Fig. 34
Fig. 35
GroundWire
23
For technical assistance call 1.800.621.5886 or contact your regional representative
10. On the back of the unitnearest the open end,remove the flatheadedscrew with a Phillipsscrewdriver while holdingthe lock nut on the insideof the cavity with pliers.(Fig. 36)
11. Pull the ballast plate freefrom housing.
12. On the side of the ballastis a switch to selectvoltage. Push the switch closest to the desired setting(120V or 240V) (Fig. 7 Pg. 8)
13. Reassemble in reverse.
14. Be sure to install ground wire connectors under lock nut, holdingballast in place(Fig. 35 Pg. 22).
Fig. 36
CONVERTING BALLAST VOLTAGE TO ALTERNATE SETTING(CONT.)
WARRANTY INFORMATION
24
Par
amou
nt P
ool &
Spa
Sys
tem
s (P
P&
SS
)2
95
E. C
orpo
rate
Pla
ce, S
uite
10
0C
hand
ler,
AZ
85
22
51
.80
0.6
21
.58
86
ww
w.1
Par
amou
nt.c
om
In c
ompl
ianc
e w
ith t
he M
agnu
son-
Mos
s W
arra
nty-
Fede
ral
Tra
de C
omm
issi
on A
ct (
Publ
ic L
aw
9306
37, P
aram
ount
Poo
l & S
pa S
yste
ms
(PP&
SS)
prov
ides
the
follo
win
g lim
ited
war
rant
ies.
CO
ND
ITIO
NS
Thi
s lim
ited
war
rant
y sh
all b
e su
bjec
t to
the
orig
inal
ow
ner
com
plyi
ng w
ith th
e fo
llow
ing
cond
i-tio
ns: 1. T
he s
wim
min
g po
ol s
hall
be k
ept f
ull o
f w
ater
at a
ll tim
es e
xcep
t for
pur
pose
s fo
r re
pair
or
mai
nten
ance
not
to e
xcee
d fiv
e (5
) da
ys.
2. T
he P
P&SS
sys
tem
sha
ll be
ope
rate
d by
the
orig
inal
ow
ner w
ith re
ason
able
car
e an
d ne
ces-
sary
mai
nten
ance
.3.
Reg
istr
atio
n ca
rd m
ust b
e m
aile
d to
PP&
SS w
ithin
thir
ty (
30)
days
of
pool
com
plet
ion.
PP
&S
S N
OZ
ZLE
AN
D B
OD
Y (
EX
CLU
DIN
G P
OO
L V
ALE
T R
ET
RO
) A
SS
EM
BLIE
SLIM
ITE
D L
IFE
TIM
E M
AN
UFA
CT
UR
ER
S W
AR
RA
NT
YPP
&SS
war
rant
s to
the
orig
inal
ow
ner,
mat
eria
ls a
nd e
quip
men
t to
be f
ree
of d
efec
ts f
or a
s lo
ng
as o
rigi
nal o
wne
r ow
ns p
ool,
dete
rmin
ed u
nder
this
war
rant
y to
be
for
the
“Lif
etim
e” o
wne
rshi
p by
ori
gina
l ow
ner f
rom
dat
e sw
imm
ing
pool
is p
last
ered
or o
ptio
nal i
nter
ior s
urfa
ce fi
nish
app
lied.
T
he m
ater
ials
and
equ
ipm
ent c
over
ed u
nder
the
“Lif
etim
e” w
arra
nty
are
the
PP&
SS N
ozzl
e an
d B
ody
Ass
embl
y. (
PVC
plu
mbi
ng i
nsta
lled,
lab
or, m
ater
ial
and
all
othe
r w
ork
perf
orm
ed b
y co
n-tr
acto
rs is
not
cov
ered
und
er P
P&SS
War
rant
y.)
PP
&S
S R
ET
RO
JET
S (
CA
RE
TA
KE
R, C
AR
ETA
KE
R 9
9, G
AM
MA
3, N
ET
N’ C
LE
AN
, P
OO
L V
ALE
T R
ET
RO
, QU
IKC
LE
AN
1, Q
UIK
CLE
AN
2)
LIM
ITE
D M
AN
UFA
CT
UR
ER
S
1-Y
EA
R W
AR
RA
NT
YPP
&SS
war
rant
s to
ori
gina
l ow
ner,
mat
eria
ls, a
nd e
quip
men
t to
be f
ree
of d
efec
ts f
or a
per
iod
of
one
(1)
year
fro
m d
ate
of p
urch
ase.
The
mat
eria
ls, p
arts
, and
/or
rela
ted
com
pone
nt p
arts
sup
plie
d or
dis
trib
uted
by
PP&
SS a
re c
over
ed u
nder
thi
s on
e (1
) ye
ar l
imite
d w
arra
nty.
(PV
C p
lum
bing
in
stal
led,
labo
r, m
ater
ial a
nd a
ll ot
her w
ork
perf
orm
ed b
y co
ntra
ctor
s is
not
cov
ered
und
er P
P&SS
W
arra
nty.
)P
P&
SS
MD
X2 A
NT
I-E
NT
RA
PM
EN
T D
EB
RIS
DR
AIN
AN
D M
DX
-R3
VG
B C
OM
PLI-
AN
T D
EB
RIS
DR
AIN
LIM
ITE
D M
AN
UFA
CT
UR
ER
S 1
-YE
AR
WA
RR
AN
TY
PP&
SS w
arra
nts
to o
rigi
nal o
wne
r, m
ater
ials
, and
equ
ipm
ent t
o be
fre
e of
def
ects
for
a p
erio
d of
on
e (1
) ye
ar f
rom
dat
e of
sw
imm
ing
pool
sta
rt-u
p. T
he m
ater
ials
, par
ts a
nd/o
r re
late
d co
mpo
nent
pa
rts
supp
lied
or d
istr
ibut
ed b
y PP
&SS
are
cov
ered
und
er th
is o
ne (1
) yea
r lim
ited
war
rant
y. (P
VC
pl
umbi
ng i
nsta
lled,
lab
or,
mat
eria
l an
d al
l ot
her
wor
k pe
rfor
med
by
cont
ract
ors
is n
ot c
over
ed
unde
r PP
&SS
War
rant
y.)
PP
&S
S S
TE
PC
LE
AN
AS
SE
MB
LIE
S L
IMIT
ED
MA
NU
FA
CT
UR
ER
S
2-Y
EA
R W
AR
RA
NT
YPP
&SS
war
rant
s to
ori
gina
l ow
ner,
mat
eria
ls, a
nd e
quip
men
t to
be f
ree
of d
efec
ts f
or a
per
iod
of
two
(2)
year
s fr
om d
ate
of p
urch
ase.
The
bod
ies,
noz
zles
, wat
er v
alve
and
/or
rela
ted
com
pone
nt
part
s su
pplie
d or
dis
trib
uted
by
PP&
SS a
re c
over
ed u
nder
thi
s tw
o (2
) ye
ars
limite
d w
arra
nty.
(P
VC
plu
mbi
ng in
stal
led,
labo
r, m
ater
ial a
nd a
ll ot
her
wor
k pe
rfor
med
by
cont
ract
ors
is n
ot c
ov-
ered
und
er P
P&SS
War
rant
y.)
PP
&S
S D
IST
RIB
UT
ION
WA
TE
R V
ALV
E L
IMIT
ED
MA
NU
FA
CT
UR
ER
S 3
-YE
AR
WA
RR
AN
TY
Para
mou
nt w
ater
val
ve m
odul
e an
d ho
usin
g ar
e w
arra
nted
-for
a p
erio
d of
3 y
ears
to
be f
ree
of
man
ufac
turi
ng d
efec
ts i
nclu
ding
wea
r an
d te
ar o
n pr
oduc
t fr
om d
ate
of p
ool
star
t-up
. Thi
s w
ar-
rant
y ap
plie
s to
the
ori
gina
l po
ol o
wne
r on
ly.
Rep
lace
men
t pa
rts
ther
eaft
er a
re w
arra
nted
for
a
peri
od o
f 1
year
.
PP
&S
S D
EB
RIS
CO
NTA
INM
EN
T C
AN
IST
ER
LIM
ITE
DM
AN
UFA
CT
UR
ER
S 3
-YE
AR
WA
RR
AN
TY
PP&
SS w
arra
nts
to o
rigi
nal o
wne
r, m
ater
ials
, and
equ
ipm
ent t
o be
free
of d
efec
ts fo
r a p
erio
d of
th
ree
(3) y
ears
from
dat
e of
sw
imm
ing
pool
sta
rt-u
p. T
he m
ater
ials
and
equ
ipm
ent c
over
ed u
nder
th
is th
ree
(3)
year
war
rant
y is
the
PP&
SS D
ebri
s C
onta
inm
ent C
anis
ter
Hou
sing
. (PV
C p
lum
b-in
g in
stal
led,
lab
or, m
ater
ial
and
all
othe
r w
ork
perf
orm
ed b
y co
ntra
ctor
s is
not
cov
ered
und
er
PP&
SS W
arra
nty.
) The
PP&
SS C
anis
ter
Deb
ris
Con
tain
men
t Bas
ket,
Inte
rnal
Can
iste
r L
id, a
nd
Top
Dec
k L
id a
re c
over
ed f
or a
per
iod
of o
ne (
1) y
ear
unde
r th
is w
arra
nty.
OT
HE
R R
ELA
TE
D S
YST
EM
PA
RT
S, A
NC
ILLA
RY
PA
RT
S A
ND
RE
PLA
CE
ME
NT
PA
RT
S L
IMIT
ED
MA
NU
FA
CT
UR
ER
S 1
-YE
AR
WA
RR
AN
TY
PP&
SS w
arra
nts
to o
rigi
nal o
wne
r, m
ater
ials
, and
equ
ipm
ent t
o be
free
of d
efec
ts fo
r a p
erio
d of
on
e (1
) yea
r fro
m d
ate
of s
wim
min
g po
ol s
tart
-up.
The
mat
eria
ls, p
arts
and
/or r
elat
ed c
ompo
nent
pa
rts
supp
lied
or d
istr
ibut
ed b
y PP
&SS
are
cov
ered
und
er t
his
one
(1)
year
lim
ited
war
rant
y.
(PV
C p
lum
bing
ins
talle
d, l
abor
, m
ater
ial
and
all
othe
r w
ork
perf
orm
ed b
y co
ntra
ctor
s is
not
co
vere
d un
der
PP&
SS W
arra
nty.
) R
epla
cem
ent p
arts
are
war
rant
ed f
or a
per
iod
of 1
yea
r fr
om
the
date
of
purc
hase
.PP
&SS
war
rant
s to
ori
gina
l ow
ner
a on
e (1
) ye
ar li
mite
d w
arra
nty
that
he
PP&
SS r
elat
ed c
om-
pone
nt p
arts
to b
e fr
ee o
f de
fect
s fr
om th
e tim
e of
inst
alla
tion.
RE
PLA
CE
ME
NT
CO
ND
ITIO
NS
Thi
s w
arra
nty
is th
e re
spon
sibi
lity
of th
e ow
ner t
o re
mov
e th
e PP
&SS
Noz
zle
& B
ody
Ass
embl
y,
Dis
trib
utor
Wat
er V
alve
Top
/Bot
tom
Hou
sing
, Deb
ris
Con
tain
men
t Can
iste
r or o
ther
rela
ted
sys-
tem
com
pone
nts
desc
ribe
d w
ith th
is w
arra
nty,
con
tact
PP&
SS fo
r an
RM
A n
umbe
r, an
d re
turn
it
to P
P&SS
. Shi
p pa
rt in
que
stio
n fr
eigh
t pre
-pai
d, a
nd u
pon
confi
rmat
ion
of d
efec
t, PP
&SS
will
re
pair
or
repl
ace
the
PP&
SS w
arra
nted
at
no c
harg
e to
the
ori
gina
l ow
ner.
The
rep
aire
d or
re-
plac
ed P
P&SS
item
will
be
retu
rned
to th
e or
igin
al o
wne
r w
ith f
reig
ht C
.O.D
. Lab
or to
rei
nsta
ll th
e re
pair
ed o
r re
plac
ed it
em is
the
sole
res
pons
ibili
ty o
f th
e ow
ner.
LIM
ITA
TIO
NS
No
war
rant
y ex
tend
s to
any
par
t of
the
PP&
SS p
arts
or
com
pone
nts
whi
ch is
cau
sed
by a
ny o
f th
e fo
llow
ing
cond
ition
s or
eve
nts:
1. D
efec
ts o
r fa
ilure
s ca
used
by
abus
e, l
ack
of r
espo
nsib
le c
are,
lac
k of
nec
essa
ry m
aint
e-na
nce,
impr
oper
ope
ratio
n, v
anda
lism
, act
s of
God
.2.
Dam
ages
or
failu
res
caus
ed b
y ab
use,
lack
of
resp
onsi
ble
care
, lac
k of
nec
essa
ry m
aint
e-na
nce,
impr
oper
ope
ratio
n, v
anda
lism
, act
s of
God
.3.
PP&
SS e
xpre
ssly
den
ies
any
resp
onsi
bilit
y or
lia
bilit
y fo
r in
cide
ntal
or
cons
eque
ntia
l da
mag
es a
risi
ng o
ut o
f, o
r as
a r
esul
t of
, use
or
owne
rshi
p of
you
r PP
&SS
par
ts o
r as
a
resu
lt of
use
or
owne
rshi
p of
you
r PP
&SS
par
ts o
r co
mpo
nent
s, o
r ot
her
rela
ted
prod
ucts
co
vere
d un
der
this
lim
ited
war
rant
y.4.
Any
def
ects
cau
sed
by a
cts
of G
od, s
uch
as s
torm
s, e
arth
quak
es, g
roun
d m
ovem
ent,
or
free
zing
, etc
., th
at a
re b
eyon
d th
e no
rmal
con
ditio
ns.
5. I
nsta
llatio
n of
the
PP&
SS S
yste
m b
y no
n-au
thor
ized
ins
talle
r m
ay r
ende
r th
is w
arra
nty
null
and
void
.So
me
stat
es d
o no
t allo
w th
e ex
clus
ion
or li
mita
tion
of in
cide
ntal
or
cons
eque
ntia
l dam
ages
, so
the
abov
e lim
itatio
ns o
r ex
clus
ions
may
not
app
ly to
you
.Im
plie
d w
arra
ntie
s ar
e lim
ited
in d
urat
ion
to t
he d
urat
ion
of th
e w
ritte
n lim
ited
war
rant
y he
re-
with
in. S
ome
stat
es d
o no
t allo
w li
mita
tions
on
how
long
an
impl
ied
war
rant
y la
sts,
so
the
abov
e lim
itatio
ns m
ay n
ot a
pply
to y
ou.
Thi
s w
arra
nty
give
you
spe
cific
lega
l rig
hts,
and
you
may
als
o ha
ve o
ther
rig
hts
that
may
var
y fr
om s
tate
to s
tate
.00
4-02
7-79
87-0
0 P
AR02
13 1
1191
0
othe
r U
.S. a
nd in
tern
atio
nal p
aten
ts p
endi
ng
CLEAR 03® WATER PURIFYING SYSTEM
25
For technical assistance call 1.800.621.5886 or contact your regional representative
512
94
68
11
12
3
10
7
1413
16 18
(opt
ional)
(opt
ional)
(opt
ional)
1715
CLEAR 03® WATER PURIFYING SYSTEM
26
For technical assistance call 1.800.621.5886 or contact your regional representative
Item Part Number DescriptionSINGLE UNIT1. 004-402-3880-00 Clear O3® Single Assembly2. 005-402-3834-00 Lamp3. 005-402-3820-00 Mounting Brackets (4Pk)4. ** Ground Lug5. 005-402-1384-00 Conduit Compression Fitting 1/2"6. ** Wiring Harness 3-Wire 12 Gauge X 6ft7. 005-402-3361-00 Tubing with Check Valve, Pump Mount,
& Wire Ties8. ** Compression Nut 1/4" X 3/8"9. ** Tubing 3/8" OD X 1/4" ID X 10ft10. ** Pump Mount Check Valve 1/4"
NPT x barb11. ** Wire Ties (4 pk)12. 005-402-3247-00 Flow Meter Kit13. ** Anchor #1014. ** Screw: 10 x 3/4 PHIL PH15. 005-402-1050-00 Clear O3® Adapter Pot Plug (optional)
16. 005-402-3824-00 Ballast & FilterAIR BLEED KIT17. 006-402-3872-00 Clear O3® Air Bleed Kit (optional)
18. 005-252-3250-00 Venturi Injector Kit (optional)* Not Shown** Not available to purchase individually
WARRANTY REGISTRATION
POOL OWNER INFORMATION
Name:
Address:
City:
State:
Zip Code:
Telephone:
Fax:
E-mail:
Pool Start-Up Date Purchased:
Type of Pool (check one): Concrete Vinyl
Fiberglass
Type of Pool System (check one): PCC 2000 PV3
Pool Valet Cyclean
Vanquish Vantage
Ecopool
POOL BUILDER INFORMATION
Name:
Address:
City:
State:
Zip Code:
When complete, remove this page, fold, stamp and return to Paramount Pool & Spa Systems.
Postal Service: 295 East Corporate Place, Suite 100 • Chandler, AZ 85225Fax: 480.753.3397E-mail: [email protected]: www.1Paramount.com/products/warranty.php
A one (1) year warranty on Clear O3®parts shall be subject to the originalowner, as stated in the “Other RelatedSystem Parts and Replacement PartsLimited Manufacturer’s 1-Year Warranty.”
Cut Here and Return to Paramount
Paramount Pool & Spa Systems
295 East Corporate Place, Suite 100
Chandler, AZ 85225
Staple Here
PlaceStampHere
Fold Here
Cut H
ere and Return to P
aramount