water heaters & storage tanks - kodsan · 2021. 3. 21. · manufactured in accordance with...

26
WATER HEATERS & STORAGE TANKS

Upload: others

Post on 03-Sep-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

WATER HEATERS & STORAGE TANKS

Page 2: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

2019PRODUCT GUIDE

ver. 1.0ver. 1.12021

WATER HEATERS & STORAGE TANKS

Page 3: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

08101214161820222426283032343638404244

WATER HEATERS & STORAGE TANKS11.11 KBS SINGLE COIL WATER HEATER

11.12 KBS-B BASIC SINGLE COIL WATER HEATER

11.13 KBD DOUBLE COIL WATER HEATER

11.14 KBD-B BASIC DOUBLE COIL WATER HEATER

11.15 KXS SINGLE ROW COIL HEAT PUMP WATER HEATER

11.16 KXD DOUBLE ROW COIL HEAT PUMP WATER HEATER

11.17 KSH HYBRID WATER HEATER

11.18 KCS SINGLE COPPER COIL WATER HEATER

11.19 KCD DOUBLE COPPER COIL WATER HEATER

11.23 KEB ELECTRIC WATER HEATER

51.11 KAT ENAMELLED ACCUMULATION TANK

101.12 KCB-S SINGLE COIL COMBI BUFFER TANK

51.12 KGA GALVANIZED ACCUMULATION TANK

101.13 KBT-B BUFFER TANK

101.14 KBT-S SINGLE COIL BUFFER TANK

101.15 KBT-D DOUBLE COIL BUFFER TANK

101.16 KBT-CB HYDRAULIC BALANCING BUFFER TANK

101.17 KBT-C BUFFER TANK WITH BAFFLE PLATE

911 KPG AUTOMATIC PUMP CONTROLLED EXPANSION SYSTEM

CONTENT

2

Page 4: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

4 5

Our VisionIn the light of the principles of honesty and trust, to provide human and environment-oriented products and services, to enlarge the business opportunities it has developed, and to be one of the top 5 companies in the world in the industry.

Our MissionWith its expert and dynamic team, innovative spirit and strong business partners, spreading our quality to the World, to create added value and difference by enlarging the business models.

About UsKodsan entered the heating industry with solid fuel boiler production when Mehmet Namık Kodaman founded the company in 1984, Ankara. It has become a leading company with its innovations, success, and people-oriented business strategies. It has grown, developed, and renewed considerably with the strength of over 35 years of experience.

As Turkey’s first and largest enamel coated water heater manufacturer, Kodsan increases its recognition in early 2000, in Turkey and surrounding countries. Kodsan manufactures enamel/ non-enamel covered water heaters, heat interface units, automatic pump controlled expansion systems, separators and filters, installment protection equipments.

Additionally, with its extensive technical service network, Kodsan provides service for energy consumption management and heat meter inspection.

Our AchievementsKodsan shines out with its advanced technology, high efficiency products and flexible production capability which can quickly adapt to the customer demands. However among these specialities, Kodsan prioritizes human health as well as the environment. Following this principle, all production processes and products are appropriate to the Europe Environment and Human Health Regulations(Reach and Rosh). For example;

• WRAS certification for the used enamel as well as for all the materials and products that contacts the drinkable water.

• Kodsan manufactures specially designed products that avoid bacteria growth such as legionella which causes the legionnaire disease.

• Kodsan is one of the limited companies that has a waste water treatment facility.

• Raw material which does not include heavy metals and with low carbon footprint are being used during production.

• Maximum sensitivity shown for recycling through all production processes.

Milestones

Founded in Ankara as a solid fuel boiler manufacturer on 400m2.

First export sales is realized.

Company reached 12.000m² closed area and 16.500m² area in total.

The number of export sales exceeded 35 countries.

The number of Export sales exceed 50 countries.

The production lines and designs of the company have been purchased, and the Heat Interface Unit manufacturing has started.

started.

Company reached 20.000m² closed area and 24.500m² area in total.

Distribution for TR market with

Enameled water heater manufacturing started.

Started to the construction of 2000m2 area in Sincan Organized Industrial Zone.

Separator production line was established.

Boiler manufaturing ended.

Design Center is approved by government.

started.

Partnership with

KODSAN

Azerbaijan, Canada, Denmark, France, Germany, Greece, Holland, Iraq, Israel, Italy, Kenya, Norway, Portugal, Qatar, Republic of South Africa, Russia, Saudi Arabia, South Korea, Spain, Sweden, Thailand, United Arab Emirates, United Kingdom, Uruguay

Main Export Countries

1984 2002 20171998 2013 20191992 2004 20182000 20162015 2020

Page 5: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

Kodsan supplies high quality spare parts and complementary items with

competitive offers.

It is possible for you to extend your product’s warranty by using Kodsan’s

modified safety kit alternatives.

SAVETIME & COST

UP TO10 YEARS WARRANTY

ONLINETECH SUPPORT

LIFELONGDURABILITY

Our top priority is customer satisfaction. Now Kodsan has an online technical

support service. You may benefit from maintenance tracking system option.

Magnesium or current anodes are the main protection elements for Kodsan water heaters. With the right periodic maintenance you may extend your

product’s life.

ABOUT SAFETY EQUIPMENTS

Max. 8 bar full-lift safety valve must be used at the cold water inlet of all enamel coated water heaters.The expansion tank should be selected by consideration of total volume of water heaters used at the system. Water heaters will be out of warranty conditions in case of not usage / failure or incorrect installation of the safety equipments.

DO NOT FORGET PERIODIC MAINTENANCE

Be sure to replace the magnesium anode rod for periodic maintenance at least once a year.The anode rod is located on the upper center of the tank. For detailed information, check the operating and installation manual.

6 7

Page 6: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.11 KBS SINGLE COIL WATER HEATER

INSTALLATION DIAGRAM

8

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

N9

ØD

N33 N8

N7

N6

N5N4

N2

H

N1

Volume 100L-3000L

Maximum Heating Power 272 kWh

Maximum Solar Collector Area 87 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

N31

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7

N8

N9

N10

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

100

PU/50

480

1110

Ø100

1½”

½”/ 9

¾”

1”

¾”

¾”

1¼”

1¼”

52

1210

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

75

1275

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

88

1460

300

PU/50

580

1860

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

98

1950

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1¼”

¾”

1”

1¼”

1¼”

150

1990

800

SPU/80

910

2110

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

245

2300

1000

SPU/80

1010

2070

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

260

2305

1500

SPU/80

1120

2375

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

2”

360

2625

2000

SPU/80

1310

2280

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

2”

455

2630

2500

SPU/80

1460

2160

Ø125

2”

½”/ 9

1½”

1½”

1½”

1½”

1¼”

2”

650

2610

3000

SPU/80

1460

2580

Ø125

2”

½”/ 9

1½”

1½”

1½”

1½”

1¼”

2”

735

2965

Code Unit 11.11.11 11.11.13 11.11.14 11.11.16 11.11.18 11.11.20 11.11.21 11.11.22 11.11.23 11.11.24 11.11.25

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

Cleaning & Control Flange STD/Ø100 mm STD/Ø125 mm OPS/Ø400 mm

STD/Ø125 mm OPS/Ø400 mm

STD/Ø125 mm OPS/Ø400 mm

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards STD/50 mm x x x

Blueshell- Recyclable polyethylene cover that provides heat-saving xSTD x x

Vinleks- Artificial Leather STDx STD STD

Magnesium Anode STDSTD STD STD

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application) OPSx OPS OPS

Electronic Anode OPSOPS OPS OPS

Steel leg system mounted on a palette from 3 different locations STD STD-xSTD x

Circle steel leg system that provides circular floor contact x x-STDx STD

Electric Heater OPS/2”OPS/1½” OPS/2” OPS/2”

Thermometer (0°C- 120°C) STD/Ø100STD/Ø63 STD/Ø100 STD/Ø100

Soft PU- 15 kg/m3 soft polyurethane x STD / 80mm STD / 80mm STD / 80mm

Soft PU- 26 kg/m3 flame retardant soft polyurethane x OPS / 80mm OPS / 80mm OPS / 80mm

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards x OPS / 80mm OPS / 80mm

OPS / 100mm OPS / 80mm

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

100L-500L 800L-1000L 1500L-2000L 2500L-3000L

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection. KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

9

N10

N32

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 7: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.12 KBS-B BASIC SINGLE COIL WATER HEATER

INSTALLATION DIAGRAM

10

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

N9

ØD

N32 N8

N7

N6

N5N4

N2

H

N1

Volume 100L-500L

Maximum Heating Power 66 kWh

Maximum Solar Collector Area 19 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 6bar / 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

N31

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7

N8

N9

N10

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

100

PU/50

480

1110

Ø100

1½”

½”/ 9

¾”

1”

¾”

¾”

1¼”

1¼”

52

1210

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

68

1275

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

76

1460

300

PU/50

580

1860

Ø100

1½”

½”/ 9

1”

1¼”

¾”

1”

1¼”

1¼”

98

1950

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1¼”

¾”

1”

1¼”

1¼”

135

1990

Code Unit 11.12.11 11.12.13 11.12.14 11.12.16 11.12.18

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Magnesium Anode

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 1 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

100L-500L

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection. KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

11

N10

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 8: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.13 KBD DOUBLE COIL WATER HEATER

12

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N11

ØD

N33

N32

N8

N9

N10

N7

N6

N5N4

N12

N2

H

N1

N31

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionLower Heat Exchanger (Coil) Inlet/Outlet Connections Upper Heat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7-N9

N8

N10

N11

N12

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

inch

kg

mm

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1¼”

1¼”

¾”

¾”

1¼”

1¼”

82

1275

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1¼”

1¼”

¾”

¾”

1¼”

1¼”

91

1460

300

PU/50

580

1860

Ø100

1½”

½”/ 9

¾”

1¼”

1¼”

¾”

¾”

1¼”

1¼”

104

1950

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1¼”

1¼”

¾”

1”

1¼”

1¼”

178

1990

800

SPU/80

910

2110

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

275

2300

1000

SPU/80

1010

2070

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

290

2305

1500

SPU/80

1120

2375

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

2”

390

2625

2000

SPU/80

1310

2280

Ø125

2”

½”/ 9

1¼”

1¼”

1¼”

1¼”

1¼”

1¼”

2”

500

2630

2500

SPU/80

1460

2160

Ø125

2”

½”/ 9

1½”

1½”

1½”

1½”

1½”

1¼”

2”

720

2610

3000

SPU/80

1460

2580

Ø125

2”

½”/ 9

1½”

1½”

1½”

1½”

1½”

1¼”

2”

805

2965

Code Unit 11.13.13 11.13.14 11.13.16 11.13.18 11.13.20 11.13.21 11.13.22 11.13.23 11.13.24 11.13.25

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

STD/Ø9 mm 2 pieces

Cleaning & Control Flange STD/Ø100 mm STD/Ø125 mm OPS/Ø400 mm

STD/Ø125 mm OPS/Ø400 mm

STD/Ø125 mm OPS/Ø400 mm

STD/50 mm x x x

xSTD x x

STDx STD STD

Magnesium Anode STDSTD STD STD

OPSx OPS OPS

Electronic Anode OPSOPS OPS OPS

Steel leg system mounted on a palette from 3 different locations STD STD-xSTD x

Circle steel leg system that provides circular floor contact x x-STDx STD

Electric Heater OPS/2”OPS/1½” OPS/2” OPS/2”

Thermometer (0°C- 120°C) STD/Ø100STD/Ø63 STD/Ø100 STD/Ø100

x STD / 80mm STD / 80mm STD / 80mm

x OPS / 80mm OPS / 80mm OPS / 80mm

x OPS / 80mm OPS / 80mm OPS / 100mm OPS / 80mm

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

160L-500L 800L-1000L 1500L-2000L 2500L-3000L

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties. 13

Volume 160L-3000L

Upper Heat Exchanger Maximum Heating Power 141 kWh

Lower Heat Exchanger Maximum Heating Power 272 kWh

Maximum Solar Collector Area 87 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 9: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.14 KBD-B BASIC DOUBLE COIL WATER HEATER

14

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N11

ØD

N33

N32

N8

N9

N10

N7

N6

N5N4

N12

N2

H

N1

N31

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionLower Heat Exchanger (Coil) Inlet/Outlet Connections Upper Heat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7-N9

N8

N10

N11

N12

G

R

Code

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

inch

kg

mm

Unit

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1¼”

1¼”

¾”

¾”

1¼”

1¼”

80

1275

11.14.13

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1¼”

1¼”

¾”

¾”

1¼”

1¼”

87

1460

11.14.14

300

PU/50

580

1860

Ø100

1½”

½”/ 9

1”

1¼”

1¼”

¾”

1”

1¼”

1¼”

104

1950

11.14.16

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1¼”

1¼”

¾”

1”

1¼”

1¼”

155

1990

11.14.18

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

160L-500L

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties. 15

Volume 160L-500L

Upper Heat Exchanger Maximum Heating Power 41 kWh

Lower Heat Exchanger Maximum Heating Power 55 kWh

Maximum Solar Collector Area 29 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 6 bar / 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 10: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.15 KXS SINGLE ROW COIL HEAT PUMP WATER HEATER

16

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N9

ØD

N3 N8

N7

N6

N5N4

N10

H

(N2)N1

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

160L-500L

17

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N7

N6

N8

N9

N10

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1”

¾”

¾”

1¼”

1¼”

80

1275

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1”

¾”

¾”

1¼”

1¼”

92

1460

300

PU/50

700

1220

Ø100

1½”

½”/ 9

1”

1”

1”

1”

1¼”

1¼”

120

1410

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1”

1”

1”

1¼”

1¼”

165

1990

Code Unit 11.15.13 11.15.14 11.15.16 11.15.18

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 160L-500L

Maximum Heating Power 251 kWh

Maximum Solar Collector Area 54 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Page 11: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.16 KXD DOUBLE ROW COIL HEAT PUMP WATER HEATER

18

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N9

ØD

N3 N8

N7

N6

N5N4

N10

H

(N2)N1

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

160L-500L

19

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube ConnectionsDomestic Cold Water Inlet ConnectionHeat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N7

N6

N8

N9

N10

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

160

PU/50

580

1135

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

95

1275

200

PU/50

580

1340

Ø100

1½”

½”/ 9

¾”

1¼”

¾”

¾”

1¼”

1¼”

113

1460

300

PU/50

700

1220

Ø100

1½”

½”/ 9

1”

1¼”

1”

1”

1¼”

1¼”

150

1410

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1¼”

1”

1”

1¼”

1¼”

210

1990

Code Unit 11.16.13 11.16.14 11.16.16 11.16.18

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 160L-500L

Maximum Heating Power 218 kWh

Maximum Solar Collector Area 17 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

N10

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Page 12: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.17 KSH HYBRID WATER HEATER

20

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N11

ØD

N3

N8

N9N10

N7

N6

N5N4

N12

H

N1

N2

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 3 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

200L-500L

STD/Ø9 mm 3 pieces

STD/Ø125 mm

x

x

STD

STD

OPS

OPS

STD

x

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L

21

Capacity

Insulation Type & Thickness

Diameter

Height

Cleaning & Control Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube Connections

Domestic Cold Water Inlet Connection

Lower Heat Exchanger (Coil) Inlet/Outlet Connections

Upper Heat Exchanger (Coil) Inlet/Outlet Connections

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7-N9

N8

N10

N11

N12

G

R

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

inch

inch

inch

kg

mm

200

PU/50

580

1340

Ø100

1½”

½”/ 9

1”

1”

1¼”

1”

1”

1¼”

1¼”

113

1460

300

PU/50

580

1860

Ø100

1½”

½”/ 9

1”

1”

1¼”

1”

1”

1¼”

1¼”

156

1950

500

PU/50

740

1845

Ø100

1½”

½”/ 9

1”

1”

1¼”

1”

1”

1¼”

1¼”

165

1990

800

SPU/80

910

2110

Ø125

2”

½”/ 9

1¼”

1”

1¼”

1¼”

1¼”

1¼”

1¼”

310

2300

1000

SPU/80

1010

2200

Ø125

2”

½”/ 9

1¼”

1”

1¼”

1¼”

1¼”

1¼”

1¼”

340

2420

Code Unit 11.17.14 11.17.16 11.17.18 11.17.20 11.17.21

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 200L-1000L

Upper Heat Exchanger Maximum Heating Power 161 kWh

Lower Heat Exchanger Maximum Solar Collector Area 10 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Page 13: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.18 KCS SINGLE COPPER COIL WATER HEATER

22

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N8

ØD

N3

N2

N1

N6

N5

N4

N9

H

N7

N7STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

STD/Ø400 mm

x

x

STD

x

OPS

STD

STD

x

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

STD/Ø9 mm 2 pieces

STD/Ø400 mm

x

x

STD

x

OPS

STD

STD-x

x-STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

STD/Ø9 mm 2 pieces

STD/Ø400 mm-STD/Ø500 mm

x

x

STD

x

OPS

STD

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

STD/Ø9 mm 2 pieces

STD/Ø500 mm

x

x

STD

x

OPS

STD

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L

23

Capacity

Insulation Type & Thickness

Diameter

Height

Heat Exchanger (Serpantine) Flange Diameter

Electric Heater Connection

Thermometer / Steel Sensor Tube Connections

Domestic Cold Water Inlet Connection

Circulation Return Connection

Domestic Hot Water Outlet Connection

Heat Exchanger (Coil) Inlet/Outlet Connections

Electronic Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

ØN1

N2

N3

N4

N5

N6

N7

N8

N9

G

R

lt

mm

mm

mm

mm

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

800

SPU/80

910

2110

Ø400

2”

½”/ 9

1¼”

1¼”

1¼”

1½”

1¼”

1¼”

263

2300

1000

SPU/80

1010

2070

Ø400

2”

½”/ 9

1¼”

1¼”

1¼”

2”

1¼”

1¼”

279

2305

1500

SPU/80

1120

2375

Ø400

2”

½”/ 9

1¼”

1¼”

1¼”

2”

1¼”

2”

376

2625

2000

SPU/80

1310

2280

Ø400

2”

½”/ 9

1¼”

1¼”

1¼”

2½”

1¼”

2”

462

2630

2500

SPU/80

1460

2160

Ø400

2”

½”/ 9

1½”

1½”

1½”

2½”

1¼”

2”

623

2610

3000

SPU/80

1460

2580

Ø500

2”

½”/ 9

1½”

1½”

1½”

2½”

1¼”

2”

700

2965

4000

SPU/80

1660

2575

Ø500

2”

½”/ 9

2”

2”

2”

3”

1¼”

2”

897

3065

5000

SPU/80

1660

3230

Ø500

2”

½”/ 9

2”

2”

2”

3”

1¼”

2”

1048

3635

Code Unit 11.18.20 11.18.21 11.18.22 11.18.23 11.18.24 11.18.25 11.18.26 11.18.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 800L-5000L

Maximum Heating Power 466 kWh

Maximum Solar Collector Area 110 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar / 16 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 14: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.19 KCD DOUBLE COPPER COIL WATER HEATER

24 25

Capacity

Insulation Type & Thickness

Diameter

Height

Lower Heat Exchanger (Serpantine) Flange Connection

Upper Heat Exchanger (Serpantine) Flange Connection

Electric Heater Connection

Thermometer / Steel Sensor Tube Connections

Domestic Cold Water Inlet Connection

Circulation Return Connection

Domestic Hot Water Outlet Connection

Lower Heat Exchanger (Coil) Inlet/Outlet Connections

Upper Heat Exchanger (Coil) Inlet/Outlet Connections

Electronic Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

ØN1-1

ØN1-2

N2

N3

N4

N5

N6

N7

N8

N9

N10

G

R

lt

mm

mm

mm

mm

mm

inch

inch/mm

inch

inch

inch

inch

inch

inch

inch

kg

mm

800

SPU/80

910

2110

Ø400

Ø274

2”

½”/ 9

1¼”

1¼”

1¼”

2½”

1¼”

1¼”

1¼”

309

2300

1000

SPU/80

1010

2070

Ø400

Ø274

2”

½”/ 9

1¼”

1¼”

1¼”

2½”

1¼”

1¼”

1¼”

327

2305

1500

SPU/80

1120

2375

Ø400

Ø274

2”

½”/ 9

1¼”

1¼”

1¼”

2½”

1¼”

1¼”

2”

427

2625

2000

SPU/80

1310

2280

Ø400

Ø324

2”

½”/ 9

1¼”

1¼”

1¼”

2½”

1½”

1¼”

2”

526

2630

2500

SPU/80

1460

2160

Ø400

Ø400

2”

½”/ 9

1½”

1½”

1½”

2½”

1½”

1¼”

2”

697

2610

3000

SPU/80

1460

2580

Ø500

Ø400

2”

½”/ 9

1½”

1½”

1½”

2½”

2”

1¼”

2”

775

2965

4000

SPU/80

1660

2575

Ø500

Ø400

2”

½”/ 9

2”

2”

2”

3”

2”

1¼”

2”

981

3065

5000

SPU/80

1660

3230

Ø500

Ø400

2”

½”/ 9

2”

2”

2”

3”

2”

1¼”

2”

1136

3635

Code Unit 11.19.20 11.19.21 11.19.22 11.19.23 11.19.24 11.19.25 11.19.26 11.19.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N9

ØD

N3

N2

N6

N5

N4

N10

H

N7

N8

N8N12

N11

N7 STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

x

x

STD

x

OPS

STD

STD

x

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

STD/Ø9 mm 2 pieces

x

x

STD

x

OPS

STD

STD-x

x-STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

STD/Ø9 mm 2 pieces

STD/Ø274 mm STD/Ø400 mm

Upper Serpantine Lower Serpantine

STD/Ø274-Ø324 mm STD/Ø400 mm

STD/Ø400 mm STD/Ø400-Ø500 mm

STD/Ø400 mm STD/Ø500 mm

x

x

STD

x

OPS

STD

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

STD/Ø9 mm 2 pieces

x

x

STD

x

OPS

STD

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L

Volume 800L-5000L

Upper Heat Exchanger Maximum Heating Power 208 kWh

Lower Heat Exchanger Maximum Heating Power 466 kWh

Maximum Solar Collector Area 110 m2

Heat Exchanger Maximum Operating Temperature 110˚C

Heat Exchanger Maximum Operating Pressure 10 bar / 16 bar

Domestic Hot Water Maximum Operating Temperature 95˚C

Domestic Hot Water Maximum Operating Pressure 10 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 15: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

11.23 KEB ELECTRIC WATER HEATER

26

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N6

ØD

N2 N5

N4

N3

N8

N7

H

N1

Volume 100L – 5000L

Maximum Electrical Heating Power 105 kWe

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 10 Bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Electric Heater

Residual Current Device

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Sheet Metal- Electrostatic Powder Painted Sheet

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Magnesium Anode

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

T&P Valve Connection

Steel Sensor Tube

Thermometer (0°C- 120°C)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x

STD/ 1½” 2kW-30kW

STD/50 mm

STD

x

x

STD

STD/ ¾”

x

OPS

STD

x

OPS

STD/Ø63

x

x

x

x

STD/ 2” 2kW-105kW

x

x

x

STD

STD

STD/ ¾”

OPS

OPS

STD

x

OPS

STD/Ø100

x

STD/80 mm

OPS/80 mm

x

STD/ 2” 2kW-105kW

x

x

x

STD

STD

STD/ ¾”

OPS

OPS

STD-x

x-STD

OPS

STD/Ø100

x

STD/80 mm

OPS/80 mm OPS/100 mm

x x

STD/ 2” 2kW-105kW

STD/ 2” 2kW-105kW

x x

x x

x x

STD STD

STD STD

STD/ ¾” STD/ ¾”

OPS OPS

OPS OPS

x x

STD STD

OPS OPS

STD/Ø100 STD/Ø100

x x

STD/80 mm STD/80 mm

OPS/80 mm OPS/80 mm

100L-500L 800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L

27

Capacity

Insulation Type & Thickness

Diameter

Height

Electric Heater Connection

Thermometer / Steel Sensor Tube Connections

Domestic Cold Water Inlet Connection

Circulation Return Connection

Domestic Hot Water Outlet Connection

Magnesium Anode Connection

P&T Valve Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5

N6

N7

N8

G

R

lt

mm

mm

mm

inch

inch/mm

inch

inch

inch

inch

inch

inch

kg

mm

100

PU/50

480

1110

½”/ 9

¾”

¾”

¾”

1¼”

¾”

1¼”

1210

160

PU/50

580

1135

½”/ 9

¾”

¾”

¾”

1¼”

¾”

1¼”

1275

200

PU/50

580

1340

½”/ 9

¾”

¾”

¾”

1¼”

¾”

1¼”

1460

300

PU/50

580

1860

½”/ 9

¾”

¾”

¾”

1¼”

¾”

1¼”

1950

500

PU/50

740

1845

½”/ 9

1”

¾”

1”

1¼”

¾”

1¼”

1990

800

SPU/80

910

2110

½”/ 9

1¼”

1”

1¼”

1¼”

¾”

1¼”

2300

1000

SPU/80

1010

2070

½”/ 9

1¼”

1”

1¼”

1¼”

¾”

1¼”

2305

1500

SPU/80

1120

2375

½”/ 9

1¼”

1”

1¼”

1¼”

¾”

2”

2625

3000

SPU/80

1460

2580

½”/ 9

1½”

1¼”

1½”

1¼”

¾”

2”

2965

2000

SPU/80

1310

2280

½”/ 9

1¼”

1”

1¼”

1¼”

¾”

2”

2630

4000

SPU/80

1660

2575

½”/ 9

1½”

1¼”

1½”

1¼”

¾”

2”

3065

2500

SPU/80

1460

2160

½”/ 9

1½”

1”

1½”

1¼”

¾”

2”

2610

5000

SPU/80

1660

3230

½”/ 9

1½”

1¼”

1½”

1¼”

¾”

2”

3635

Code Unit 11.23.11 11.23.13 11.23.14 11.23.16 11.23.18 11.23.20 11.23.21 11.23.22 11.23.2511.23.23 11.23.2611.23.24 11.23.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

THE HEATER MAY BE CHOSEN OPTIONALLY

THE WEIGHT OF THE PRODUCTS MAY VARY ACCORDING TO CHOSEN HEATER/S. THE WEIGHT OF THE PRODUCTS WITHOUT HEATER/S ARE EQUAL TO ENAMELED ACCUMULATION TANK.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Page 16: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

51.11 KAT ENAMELLED ACCUMULATION TANK

28

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 2 pieces

STD/Ø125 mm OPS/Ø400 mm

x

x

STD

STD

OPS

OPS

STD

x

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L

STD/Ø9 mm 2 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

STD/Ø63

x

x

x

100L-500L

STD/Ø9 mm 2 pieces

STD/Ø125 mm OPS/Ø400 mm

x

x

STD

STD

OPS

OPS

STD-x

x-STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

1500L-2000L

STD/Ø9 mm 2 pieces

STD/Ø125 mm OPS/Ø400 mm

x

x

STD

STD

OPS

OPS

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

2500L-3000L

STD/Ø9 mm 2 pieces

STD/Ø125 mm OPS/Ø400 mm

x

x

STD

STD

OPS

OPS

x

STD

OPS/2”

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

4000L-5000L

29

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections

Cleaning & Control Flange Diameter

Thermometer / Steel Sensor Tube Connections

Circulation Return Connection

Electric Heater Connection

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

lt

mm

mm

mm

inch

inch

inch/mm

inch

inch

inch

inch

kg

mm

100

PU/50

480

1110

1”

Ø100

½”/ 9

¾”

1½”

1¼”

1¼”

40

1210

160

PU/50

580

1135

1¼”

Ø100

½”/ 9

¾”

1½”

1¼”

1¼”

58

1275

200

PU/50

580

1340

1¼”

Ø100

½”/ 9

¾”

1½”

1¼”

1¼”

65

1460

300

PU/50

580

1860

1¼”

Ø100

½”/ 9

¾”

1½”

1¼”

1¼”

75

1950

500

PU/50

740

1845

1¼”

Ø100

½”/ 9

¾”

1½”

1¼”

1¼”

113

1990

800

SPU/80

910

2110

1½”

Ø125

½”/ 9

1¼”

2”

1¼”

1¼”

190

2300

1000

SPU/80

1010

2070

1½”

Ø125

½”/ 9

1¼”

2”

1¼”

1¼”

205

2305

1500

SPU/80

1120

2375

1½”

Ø125

½”/ 9

1¼”

2”

1¼”

2”

295

2625

2500

SPU/80

1460

2160

2”

Ø125

½”/ 9

1½”

2”

1¼”

2”

520

2610

4000

SPU/80

1660

2575

3”

Ø125

½”/ 9

2”

2”

1¼”

2”

760

3065

2000

SPU/80

1310

2280

1½”

Ø125

½”/ 9

1¼”

2”

1¼”

2”

370

2630

3000

SPU/80

1460

2580

2”

Ø125

½”/ 9

1½”

2”

1¼”

2”

575

2965

5000

SPU/80

1660

3230

3”

Ø125

½”/ 9

2”

2”

1¼”

2”

890

3635

V

i

ØD

H

N1

N2

N3

N4

N5

N6

N7

G

R

Code Unit 51.11.11 51.11.13 51.11.14 51.11.16 51.11.18 51.11.20 51.11.21 51.11.22 51.11.24 51.11.2651.11.23 51.11.25 51.11.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N6

ØD

N12 N14

N13

N7

H

N11

N33

N32

N31

N2

N5

N4

Volume 100L – 5000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 10 Bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Domestic Cold Water

Domestic Hot Water

Heating Water Inlet

Heating Water Return

Page 17: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.12 KCB-S SINGLE COIL COMBI BUFFER TANK

30

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Steel Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

STD/Ø9 mm 4 pieces

STD/Ø125 mm STD/Ø125 mm STD/Ø125 mm

x

x

STD

STD

OPS

OPS

STD

x

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

x

STD/Ø9 mm 4 pieces

STD/Ø100 mm

STD/50 mm

STD

x

STD

x

OPS

STD

x

OPS/1½”

OPS/Ø63

x

x

x

500L/ 100L-160L

800L-1000L/ 160L-200L

1500L/ 200L-350L

2000L/ 200L-350L

STD/Ø9 mm 4 pieces

x

x

STD

STD

OPS

OPS

STD

x

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

x

STD/Ø9 mm 4 pieces

x

x

STD

STD

OPS

OPS

x

STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

x

31

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

ØD

N14

N13 N17

N12 N16

N18

N15

N12

H

N11

N5

N6

N34

N33

N32

N31N2

N4

N3

N7N9

N8N10

N11

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections

Electric Heater Connection

Thermometer & Sensor Tube Connections

Drain Connection

Heat Exchanger (Serpantine) Inlet/Outlet Connections

Domestic Cold Water Inlet Connection

Domestic Hot Water Outlet Connection

Inner Tank Air Ventilating Connections

Outer Tank Air Ventilating Connections

Magnesium Anode Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7

N8

N9

N10

N11

N12

G

R

lt

mm

mm

mm

inch

inch

inch

inch

inch

inch

inch

inch

inch

inch

inch

kg

mm

500/100

PU/50

740

1845

1¼”

1½”

½”

1¼”

1¼”

¾”

¾”

½”

½”

1¼”

1¼”

176

1990

500/160

PU/50

740

1845

1¼”

1½”

½”

1¼”

1¼”

¾”

¾”

½”

½”

1¼”

1¼”

190

1990

800/160

SPU/80

910

2110

1¼”

2”

½”

1¼”

1¼”

¾”

¾”

½”

½”

1¼”

1¼”

290

2300

1000/160

SPU/80

1010

2070

1¼”

2”

½”

1¼”

1¼”

¾”

¾”

½”

½”

1¼”

1¼”

305

2305

1000/200

SPU/80

1010

2070

1¼”

2”

½”

1¼”

1¼”

¾”

¾”

½”

½”

1¼”

1¼”

317

2305

1500/200

SPU/80

1120

2375

1½”

2”

½”

1½”

1¼”

¾”

¾”

½”

½”

1¼”

2”

415

2625

1500/350

SPU/80

1120

375

1½”

2”

½”

1½”

1¼”

1”

1”

½”

½”

1¼”

2”

427

2625

2000/200

SPU/80

1310

2280

1½”

2”

½”

1½”

1¼”

1”

1”

½”

½”

1¼”

2”

510

2630

2000/350

SPU/80

1260

2280

1½”

2”

½”

1½”

1¼”

1”

1”

½”

½”

1¼”

2”

522

2605

Code Unit 101.12.18.1 101.12.18.2 101.12.20.2 101.12.21.2 101.12.21.3 101.12.22.3 101.12.22.4 101.12.23.3 101.12.23.4

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 500L/100L-2000L/350L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure İç Tank: 6 bar / Dış Tank: 3 bar

Inner Surface Coating Tank inner surface is enamelled (glass-lined) in accordance with DIN 4753-3 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Heating Water Inlet

Heating Water Return

Domestic Cold Water

Domestic Hot Water

Page 18: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

51.12 KGA GALVANIZED ACCUMULATION TANK

32

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N6

ØD

N12

N4

N11

N2

N14

N5

N13N31

N32

N33

N34

N7

H

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Sensor Tube

Cleaning & Control Flange

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Electric Heater

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

OPS/¾” 4 pieces

STD/DN100

x

x

STD

x

x

x

STD

x

OPS/1”-1¼”

x

STD/60 mm

OPS/60 mm

x

OPS/¾” 4 pieces

STD/DN125

x

x

STD

x

x

x

STD

x

OPS/1½”

x

STD/60 mm

OPS/60 mm

x

OPS/¾” 4 pieces

STD/DN150

x

x

STD

x

x

x

STD

x

OPS/2”

x

STD/60 mm

OPS/60 mm

x

OPS/¾” 4 pieces

STD/DN150

x

x

STD

x

x

x

STD

x

OPS/2”

x

STD/60 mm

OPS/60 mm

x

800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L

33

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections

Cleaning & Control Flange Diameter

Thermometer & Sensor Connections

Electric Heater Connection

Circulation Return Connection

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

N4

N5

N6

N7

G

R

lt

mm

mm

mm

inch

DN

inch

inch

inch

inch

inch

kg

mm

800

SPU/60

870

2100

1½”

DN100

¾”

1”

1”

1½”

1”

220

2275

1000

SPU/60

970

2090

2”

DN100

¾”

1¼”

1¼”

2”

1¼”

250

2305

1500

SPU/60

1080

2150

2½”

DN125

¾”

1½”

1½”

2½”

1½”

360

2475

2000

SPU/60

1270

2650

2½”

DN125

¾”

1½”

1½”

2½”

1½”

420

2920

2500

SPU/60

1420

2480

3”

DN150

¾”

2”

2”

3”

2”

490

2860

3000

SPU/60

1420

2880

3”

DN150

¾”

2”

2”

3”

2”

540

3215

4000

SPU/60

1620

2820

3”

DN150

¾”

2”

2”

3”

2”

820

3255

5000

SPU/60

1620

3420

3”

DN150

¾”

2”

2”

3”

2”

930

3790

Code Unit 51.12.20 51.12.21 51.12.22 51.12.23 51.12.24 51.12.25 51.12.26 51.12.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 800L – 5000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 10 Bar / 16 bar

Inner Surface Coating Tank is made of S355J2 quality steel and galvanized in accordance with TS EN ISO 1461 standard.

Relief valves with membrane should be installed at higher level than top of the tank.Thus it is protected against high temperature and calcification and it is not necessary to discharge the tank when working on the relief valve.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Heating Water Inlet

Heating Water Return

Domestic Cold Water

Domestic Hot Water

Page 19: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.13 KBT-B BUFFER TANK

34 35

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

Volume 100L – 5000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 6 Bar

N5

ØD

N14

N13 N17

N12 N16

N18

N15

N6

H

N11

N33

N32

N31

N2

N4

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Cleaning & Control Flange

Electric Heater

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Air Ventilating Connection

Steel Sensor Tube

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x x x x x x

OPS/Ø9 mm 3 pieces

OPS/Ø9 mm 3 pieces

OPS/Ø9 mm 3 pieces

OPS/Ø9 mm 3 pieces

OPS/Ø9 mm 3 pieces

OPS/Ø9 mm 3 pieces

STD/50 mm STD/50 mm

STD STD

x x

x x

STD/1¼” STD/1¼”

x x

x x

STD STD

x x

x OPS/1½”

OPS/Ø63 OPS/Ø63

x x

x x

x x

x

x

STD

x

STD/1¼”

OPS

x

STD

x

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

x

x

STD

x

STD/1¼”

OPS

x

STD-x

x-STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

x x

x x

STD STD

x x

STD/1¼” STD/1¼”

OPS OPS

x x

x x

STD STD

OPS/2” OPS/2”

OPS/Ø100 OPS/Ø100

STD/80 mm STD/80 mm

OPS/80 mm OPS/80 mm

OPS/80 mm OPS/80 mm

100L-300L 500L 800L-1000L 1500L-2000L 2500L-3000L 4000L-5000L

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections*

Electric Heater Connection

Thermometer & Sensor Tube Connections

Drain Connection

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

lt

mm

mm

mm

inch

inch

inch

inch

inch

inch

kg

mm

100

PU/50

480

1110

1”

-

½”

1”

1¼”

1¼”

36

1210

160

PU/50

580

1135

1¼”

-

½”

1¼”

1¼”

1¼”

54

1275

200

PU/50

580

1340

1¼”

-

½”

1¼”

1¼”

1¼”

60

1460

300

PU/50

700

1220

1¼”

-

½”

1¼”

1¼”

1¼”

70

1410

500

PU/50

740

1845

1¼”

1½”

½”

1¼”

1¼”

1¼”

106

1990

800

SPU/80

910

2110

1½”

2”

½”

1½”

1¼”

1¼”

183

2300

1000

SPU/80

1010

2070

1½”

2”

½”

1½”

1¼”

1¼”

197

2305

1500

SPU/80

1120

2375

1½”

2”

½”

1½”

1¼”

2”

286

2625

2500

SPU/80

1460

2160

2”

2”

½”

2”

1¼”

2”

510

2610

4000

SPU/80

1660

2575

3”

2”

½”

3”

1¼”

2”

745

3065

2000

SPU/80

1310

2280

1½”

2”

½”

1½”

1¼”

2”

360

2630

3000

SPU/80

1460

2580

2”

2”

½”

2”

1¼”

2”

563

2965

5000

SPU/80

1660

3230

3”

2”

½”

3”

1¼”

2”

870

3635

V

i

ØD

H

N1

N2

N3

N4

N5

N6

G

R

Code Unit 101.13.11 101.13.13 101.13.14 101.13.16 101.13.18 101.13.20 101.13.21 101.13.22 101.13.24 101.13.26101.13.23 101.13.25 101.13.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-5000L products, 4 for the primary circuit, and 4 for the secondary circuit.

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Heating Water Inlet

Heating Water Return

Page 20: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.14 KBT-S SINGLE COIL BUFFER TANK

36 37

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N7

ØD

N14

N13 N17

N12 N16

N18

N15

N8

H

N11

N33

N32N6

N5

N31

N2

N4STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Cleaning & Control Flange

Electric Heater

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Air Ventilating Connection

Steel Sensor Tube

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x

OPS/Ø9 mm 3 pieces

STD/50 mm

STD

x

x

STD/1¼”

x

x

STD

x

x

OPS/Ø63

x

x

x

160L-300L

x

OPS/Ø9 mm 3 pieces

STD/50 mm

STD

x

x

STD/1¼”

x

x

STD

x

OPS/1½”

OPS/Ø63

x

x

x

500L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

STD

x

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

STD-x

x-STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

1500L-2000L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

x

STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

2500L-3000L

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections*

Electric Heater Connection

Thermometer & Sensor Tube Connections

Heat Exchanger (Coil) Inlet/Outlet Connections

Drain Connection

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

lt

mm

mm

mm

inch

inch

inch

inch

inch

inch

inch

kg

mm

160

PU/50

580

1135

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

70

1275

200

PU/50

580

1340

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

71

1460

300

PU/50

700

1220

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

93

1410

500

PU/50

740

1845

1¼”

1½”

½”

1¼”

1¼”

1¼”

1¼”

143

1990

800

SPU/80

910

2110

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

238

2300

1000

SPU/80

1010

2070

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

252

2305

1500

SPU/80

1120

2375

1½”

2”

½”

1½”

1¼”

1¼”

2”

351

2625

2000

SPU/80

1310

2280

1½”

2”

½”

1½”

1¼”

1¼”

2”

445

2630

3000

SPU/80

1460

2580

2”

2”

½”

2”

1½”

1¼”

2”

722

2965

2500

SPU/80

1460

2160

2”

2”

½”

2”

1½”

1¼”

2”

640

2610

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7

N8

G

R

Code Unit 101.14.13 101.14.14 101.14.16 101.14.18 101.14.20 101.14.21 101.14.22 101.14.23 101.14.25101.14.24

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-3000L products, 4 for the primary circuit, and 4 for the secondary circuit.

Volume 160L – 3000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 6 Bar

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Heating Water Inlet

Heating Water Return

Page 21: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.15 KBT-D DOUBLE COIL BUFFER TANK

38 39

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N9

ØD

N14

N13 N17

N12 N16

N18

N15

N10

H

N11

N33

N32N6

N7

N8

N5

N31

N2

N4STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Cleaning & Control Flange

Electric Heater

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Air Ventilating Connection

Steel Sensor Tube

Thermometer (0°C- 120°C)

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x

OPS/Ø9 mm 3 pieces

STD/50 mm

STD

x

x

STD/1¼”

x

x

STD

x

x

OPS/Ø63

x

x

x

160L-300L

x

OPS/Ø9 mm 3 pieces

STD/50 mm

STD

x

x

STD/1¼”

x

x

STD

x

OPS/1½”

OPS/Ø63

x

x

x

500L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

STD

x

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

800L-1000L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

STD-x

x-STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm OPS/100 mm

1500L-2000L

x

OPS/Ø9 mm 3 pieces

x

x

STD

x

STD/1¼”

OPS

x

x

STD

OPS/2”

OPS/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

2500L-3000L

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections

Electric Heater Connection

Thermometer & Sensor Tube Connections

Lower Heat Exchanger (Coil) Inlet/Outlet Connections

Upper Heat Exchanger (Coil) Inlet/Outlet Connections

Drain Connection

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

lt

mm

mm

mm

inch

inch

inch

inch

inch

inch

inch

inch

kg

mm

160

PU/50

580

1135

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

1¼”

78

1275

200

PU/50

580

1340

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

1¼”

86

1460

300

PU/50

700

1220

1¼”

-

½”

1¼”

1¼”

1¼”

1¼”

1¼”

102

1410

500

PU/50

740

1845

1¼”

1½”

½”

1¼”

1¼”

1¼”

1¼”

1¼”

170

1990

800

SPU/80

910

2110

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

1¼”

268

2300

1000

SPU/80

1010

2070

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

1¼”

282

2305

1500

SPU/80

1120

2375

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

2”

381

2625

2000

SPU/80

1310

2280

1½”

2”

½”

1½”

1¼”

1¼”

1¼”

2”

490

2630

3000

SPU/80

1460

2580

2”

2”

½”

2”

1½”

1½”

1¼”

2”

793

2965

2500

SPU/80

1460

2160

2”

2”

½”

2”

1½”

1½”

1¼”

2”

710

2610

V

i

ØD

H

N1

N2

N3

N4

N5-N6

N7-N8

N9

N10

G

R

Code Unit 101.15.13 101.15.14 101.15.16 101.15.18 101.15.20 101.15.21 101.15.22 101.15.23 101.15.25101.15.24

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have internal thread connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

* : The number of energy inlet/outlet connections is 4 for 100L-300L products, 2 for the primary circuit, 2 for the secondary circuit; and 8 for 500L-3000L products, 4 for the primary circuit, and 4 for the secondary circuit.

Volume 160L – 3000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 6 Bar

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAMHeating Water Inlet

Heating Water Inlet

Heating Water Return

Heating Water Return

Page 22: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.16 KBT-CB HYDRAULIC BALANCING BUFFER TANK

40

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N2

ØD

N12

N11

N14

N13

N3

H

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.* Polyurethane insulation can be applied with threaded connection on request for bulk order.

Cleaning & Control Flange

Electric Heater

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Air Ventilating Connection

Thermometer (0°C- 120°C)

Steel Sensor Tube

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x

x

x

x

STD

x

OPS

x

STD

x

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

800L-1000L

x

x

OPS/50 mm

x

STD

x

x

x

STD

x

STD/1¼”

x

x

STD/80 mm

x

x

100L-500L

x

x

x

x

STD

x

OPS

x

STD-x

x-STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm OPS/100 mm*

1500L-2000L

x

x

x

x

STD

x

OPS

x

x

STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

2500L-3000L

x

x

x

x

STD

x

OPS

x

x

STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

4000L-5000L

41

Capacity

Insulation Type & Thickness

Diameter

Height

Primary/Secondary Energy Inlet/Outlet Connections

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

N1

N2

N3

G

R

lt

mm

mm

mm

inch/DN

inch

inch

kg

mm

100

SPU/80

540

1115

Threaded 1½”

1¼”

1¼”

46

1240

300

SPU/80

760

1225

Threaded 2”

1¼”

1¼”

80

1440

500

SPU/80

800

1850

Threaded 2½”

1¼”

1¼”

118

2015

800

SPU/80

910

2110

Flanged DN80

1¼”

1¼”

199

2300

1000

SPU/80

1010

2070

Flanged DN100

1¼”

1¼”

215

2305

1500

SPU/80

1120

2375

Flanged DN125

1¼”

2”

311

2625

3000

SPU/80

1460

2580

Flanged DN150

1¼”

2”

593

2965

2000

SPU/80

1310

2280

Flanged DN145

1¼”

2”

385

2630

4000

SPU/80

1660

2575

Flanged DN200

1¼”

2”

806

3065

2500

SPU/80

1460

2160

Flanged DN150

1¼”

2”

540

2610

5000

SPU/80

1660

3230

Flanged DN200

1¼”

2”

931

3635

Code Unit 101.16.11 101.16.16 101.16.18 101.16.20 101.16.21 101.16.22 101.16.25101.16.23 101.16.26101.16.24 101.16.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; products 100L-300L have internal thread connection, products 800L-5000L have flaged connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Volume 100L – 5000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 6 Bar

Flange Connection Pressure Class PN16

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Dışarıda kullanıma uygun su geçirmez PVC kullanım ünitesi (Izomax izolasyonu kullanıldığı takdirde, opsiyonel olarak sunulur.)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

INSTALLATION DIAGRAM

Coolingor

HeatingSystem

Page 23: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

101.17 KBT-C BUFFER TANK WITH BAFFLE PLATE

42

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

N2

ØD

N11 N12

N3

H

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Cleaning & Control Flange

Electric Heater

Magnesium Anode

Electronic Anode

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Air Ventilating Connection

Thermometer (0°C- 120°C)

Steel Sensor Tube

INSU

LATI

ON

CO

ATIN

GEQ

UIP

MEN

TCA

THO

DIC

PR

OTE

C-TI

ON

CARR

IER

ELEM

ENT

x

x

x

x

STD

x

OPS

x

STD

x

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

800L-1000L

x

x

x

x

STD

x

x

x

STD

x

STD/1¼”

x

x

STD/80 mm

x

x

100L-500L

x

x

x

x

STD

x

OPS

x

STD-x

x-STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm OPS/100 mm*

1500L-2000L

x

x

x

x

STD

x

OPS

x

x

STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

2500L-3000L

x

x

x

x

STD

x

OPS

x

x

STD

STD/1¼”

x

x

STD/80 mm

x

OPS/80 mm

4000L-5000L

43

Capacity

Insulation Type & Thickness

Diameter

Height

Number of Baffle

Primary/Secondary Energy Inlet/Outlet Connections

Air Ventilating Connection

Blind Connection

Gross Weight

Tilt Height

V

i

ØD

H

-

N1

N2

N3

G

R

lt

mm

mm

mm

pieces

DN

inch

inch

kg

mm

100

SPU/80

540

1115

Flanged DN50

1¼”

1¼”

40

1240

300

SPU/80

760

1225

Flanged DN50

1¼”

1¼”

78

1440

1

500

SPU/80

800

1850

Flanged DN65

1¼”

1¼”

117

2015

800

SPU/80

910

2110

Flanged DN80

1¼”

1¼”

198

2300

1000

SPU/80

1010

2070

Flanged DN100

1¼”

1¼”

232

2305

1500

SPU/80

1120

2375

Flanged DN125

1¼”

2”

325

2625

3000

SPU/80

1460

2580

Flanged DN150

1¼”

2”

701

2965

2000

SPU/80

1310

2280

Flanged DN125

1¼”

2”

405

2630

4000

SPU/80

1660

2575

Flanged DN200

1¼”

2”

894

3065

2500

SPU/80

1460

2160

Flanged DN150

1¼”

2”

577

2610

5000

SPU/80

1660

3230

Flanged DN200

1¼”

2”

931

3635

Code Unit 101.17.11 101.17.16 101.17.18 101.17.20 101.17.21 101.17.22 101.17.25101.17.23 101.17.26101.17.24 101.17.27

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have flanged connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

2 3

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

Volume 100L – 5000L

Domestic Hot Water Maximum Operating Temperature 95°C

Domestic Hot Water Maximum Operating Pressure 6 Bar

Flange Connection Pressure Class PN16

INSTALLATION DIAGRAM

Coolingor

HeatingSystem

Page 24: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

911 KPG AUTOMATIC PUMP CONTROLLED EXPANSION SYSTEM

44

The installaion diagram shown above is just an example. The installion must be done according to updated standards and instructions.

45

Capacity

Maximum Allowable Working Pressure

Width

Depth

Height

Domestic Cold Water Inlet Connection

Expansion Line Inlet Connection

Pressurization Line Outlet Connection

Storage Tank Connection

Maximum Flolw Rate

Power

Gross Weight

Tilt Height

V

P

D1

D2

H

N1

N2

N3

N4

Q

Ppower

G

R

Code

lt

bar

mm

mm

mm

inch

icnh

inch

inch

m3/h

kW

kg

mm

Unit

min 500L

6

650

650

960

1”

1”

1”

1¼”

6

1,8

135

1100

101.17.11

min 500L

10

650

650

960

1”

1”

1”

1¼”

1

2,7

142

1100

101.17.16

min 500L

16

650

650

960

1”

1”

1”

1¼”

3,2

4,9

160

1100

101.17.18

The table shown above is prepared based on spare parts and equipments which belong to the standard products; all products have flanged connection.

KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

Capasity Min. 500LTank 51.11 Enameled Accumulation TankPump Grundfos CM SerieControl System 7” Touch PanelMaximum Operating Temperature 95˚CMaximum Operating Pressure 6 bar / 10 bar / 16 barControl Circuit Voltage 230 V ACAutomatic Filling System Avaliable

INSTALLATION DIAGRAM

Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards.

Automatic Pump Controlled Expansion System is a technological devices developed to absorb the volume changes that may occur at the heating and cooling systems and stabilize the installment pressure.

Considering the expansion and contraction of water due to the temperature variation, the amount of water changes in the system. The device keeps the pressure in the installment in balance with 0,1 bar precision by transmitting the water among the tank and installment through the proportioning valves and pumps.

STD: Abbreviation for spare parts and equipments which belong to the standard products. OPS: Abbreviation for the optional spare parts and equipments for non-standart products.

Cleaning & Control Flange

Pump

PU- 42kg/m3 HCFC-free polyurethane in accordance with the 814/2013 EU ErP Comission Regulations and TS EN 12897 Standards

Sheet Metal- Electrostatic Powder Painted Sheet

Blueshell- Recyclable polyethylene cover that provides heat-saving

Vinleks- Artificial Leather

Izoqua- Waterproof PVC unit which is suitable for exterior usage. (Optional only with the izomax insulation application)

Steel leg system mounted on a palette from 3 different locations

Circle steel leg system that provides circular floor contact

Rubber leg system mounted on a cell from 4 locations

Automatic Filling System

Steel Sensor Tube

Thermometer (0°C- 120°C)

Soft PU- 15 kg/m3 soft polyurethane

Soft PU- 26 kg/m3 flame retardant soft polyurethane

Izomax- 50kg/m3 insulation with d0 fire class as well as with BL-S3 compatible with the ErP regulations following the 814/2013 EU Comission Regulations and TS EN 12897 Standards

INSU

LATI

ON

TAN

KTA

NK

TAN

KTA

NK

UN

ITU

NIT

UN

IT

CO

ATIN

GEQ

UIP

MEN

TCA

RRIE

R EL

EMEN

T

OPS/Ø9 mm 2 pieces

OPS/Ø9 mm 2 pieces

OPS/Ø9 mm 2 pieces

OPS/Ø9 mm 2 pieces

OPS/Ø9 mm 2 pieces

STD/4”

STD/50 mm

x

STD

x

STD

STD

STD

x

STD

STD

STD/Ø63

x

x

x

STD/5” OPS/16”

x

STD

x

OPS

STD

STD

STD

x

STD

STD

STD/Ø100

STD/80 mm

OPS/80 mm

OPS/80 mm

STD/5” OPS/16”

x

STD

x

OPS

STD

STD

STD-x

x-STD

STD

STD

STD/Ø100

STD/80 mm

STD/80 mm

OPS/80 mm OPS/100 mm*

500L 800L-1000L 1500L-2000L

STD/5” OPS/16”

x

STD

x

OPS

STD

STD

x

STD

STD

STD

STD/Ø100

STD/80 mm

STD/80 mm

OPS/80 mm

2500L-3000L

STD/5” OPS/16”

x

STD

x

OPS

STD

STD

x

STD

STD

STD

STD/Ø100

STD/80 mm

STD/80 mm

OPS/80 mm

4000L-5000L

Page 25: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

|IMPORTANT NOTES

• We highly recommend to follow instructions specified at the user and installation guide attached to your product in order to secure of using it in safe and efficient.

• Safety Valve, expansion tank and, if required, pressure reducer valve should be used with our products (water heaters and storage tanks).

• KODSAN reserves the right to change the product specifications, technical information and installation diagrams without any notifications. All information written on this page can not be copied or used without permission of KODSAN. Kodsan can not be held responsible if any of the technical information and schemes are considered exemplary by third parties.

• You may contact Kodsan for more details about your product.

Two-Way Motorized Valve

Ball ValveDrain Valve

Shut Off Valve

Pressure Relief Valve

Air Relief Cock

Radiator or Underfloor Heating System

Pressure Gauge

Air Separator

SolarPanel

HeatPump

Heat Exchanger

Combi

Usage Area

Dirt Separator

Membrane Expansion Tank

Underfloor Heating

Radiator

Thermometer

Safety Thermostat

Twin-Head Pump

Pump

Three-Way Motorized Valve

Three-Way Thermostatic Valve

Pressure Release Valve

Thermostatic Check Valve

Bypass Valve

Three-Way Modulating Motorized Valve

Check Valve

Strainer

|SYMBOLS

46 47

Page 26: WATER HEATERS & STORAGE TANKS - Kodsan · 2021. 3. 21. · Manufactured in accordance with 2014/68/EU Pressure Equipment Directive, TS EN 13445-3, TS736 and TS EN 12897 standards

www.kodsan.com.tr