vwh, vwg, vww · wshp; vwh,vwg,vww 007-012 vintage a rev. a 08/17 rpl 7000265 / page 3 parts list...
TRANSCRIPT
AAF
VerticalWater Source Heat Pump
VWH, VWG, VWW007 - 012Vintage A
Last Manufactured: 1993
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Replacement Parts List No. 700026500 Revision A 08/2017
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 2
Contents
Parts List Revision History ................................................................................................................ 3
Nomenclatures Serial Number ................................................................................................................................ 4 Model Number ............................................................................................................................... 4
Field Installed Accessories Thermostats and Subbases for Electromechanical Control Units ................................................. 5 Thermostats and Subbases for Mark IV Control Units .................................................................. 5 Thermostat Accessories ................................................................................................................ 6 Hoses & Valves ............................................................................................................................. 6 Filters and Filter Components ....................................................................................................... 6 Unit Accessories ............................................................................................................................ 7
Refrigeration Circuit Diagram ......................................................................................................................................... 8 Components ............................................................................................................................ 9, 10
Fan and Housing Assembly .............................................................................................................11 Control Box Accessory & Standard Control Layout ......................................................................................... 12 MicroTech Control Layout ............................................................................................................ 13 Components .......................................................................................................................... 14, 15
Critical Parts List......................................................................................................................... CPL1
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 3
Parts List Revision History
Revision Date Description
New 1/13 New A 08/17 Rebrand Daikin. Delete sheet metal. Change Diagrams from tif to psd. Page 4- Change Serial Number to correct nomenclature. Pages 11-12 Combine onto one page Fan and Housing Assembly (Page 11). Pages 17-19 Delete Panels and Cabinet Assembly. CPL1- Rebrand and delete Refrigeration Circuit.
Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 4
007A= 7,100 Nominal Cooling Btuh009A= 8,800 Nominal Cooling Btuh012A= 12,500 Nominal Cooling Btuh
VWH= Floor Concealed Vertical Water Source Heat PumpVWG= Ceiling Concealed Vertical Cooling Only VWW= Ceiling Concealed Vertical Ext. Range Heat Pump
Model NumberVWG 012A E G L
Unit Size / Vintage
Model Type Return Air ArrangementL= Left Hand ReturnR= Right Hand Return
Control SystemE= Electromechanical ControlM= Mark IV Control C= MicroTech Control
Voltage A= 115/60/1 G= 208-230/60/1 N= 265/60/1 J= 230/50/1
Digits 1-3
Digits 4-7
Digit 10
Digit 9
Digit 8
Nomenclatures
7 U A 00000 00
Serial Number
Month Manufactured
Engineering Revision
S= 1987T= 1988U= 1989V= 1990W=1991X= 1992Y= 1993
Plant Identification Number7= Auburn
Year Manufactured A= January B= February C= March D= April E= May F= June
Serial Number
G= July I= August J= September K= October L= November M= December
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 5
PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-1000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch.
1 Replaces 060602301 (Digistat HP-2000DC) Thermostat.
1 Replaces 060602301 (Digistat HP-2000DC) Thermostat.2 Deluxe Thermostat was 060685501 (T874D1686) which has been phas ed out. When replacing 060685501 with 061202401, must also replace the Subbase from 060684801 to 061202601. Thermostat 061202401 is not compatible with 060684801 (Q674C1298) Subbase.
Thermostats & Subbases for Mark IV Control Units
Field Installed Accessories
DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires factory installed night setback relay or field installed night setback or night setback/demand control relay. Night set-back bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Requires minimum of 6 wires.
STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch.
Description Part Number
STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch.
Thermostat 060687201
060687401
Thermostat 060687301
803005245(Includes subbase)
Subbase
Subbase 060687401
PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. Digistat HP-1000DC/BO. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch.
61212801(Includes subbase)
612129011
(Includes subbase)
STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch.STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch.
Thermostat 060685301
060684801
803005245(Includes subbase)
STANDARD MANUAL & AUTO CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch.
Thermostat
Thermostat
060684901
060685301
Subbase
Subbase
SubbaseDELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK AND OVERRIDE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. Night setback bulb set 12o F below day heat setpoint. System "Off-Auto" switch and fan "On-Auto-Override" switch.
061202401 2
061202601
STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE FOR OPERATING TWO UNITS. Honeywell T874/Q674. LED for "Ser-vice." Mounts horizontal. System "Off-Auto" switch. 060684701Subbase
060685201Thermostat
PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-1000DC. Auto or man-ual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch
61212801(Includes subbase)
061212901 1
(Includes subbase)
PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. "Heat-Auto-Cool" switch and fan "On-Auto" switch.
Description Part Number
Thermostats & Subbases for Electromechanical Control Units
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 6
Field Installed Accessories
DELUXE LOCKING COVER FOR T874/Q674 THERMOSTATS. Honeywell TG504A. Applies only to T874/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock and keys.
7-DAY TIME CLOCK.
UNIVERSAL THERMOSTAT GUARD. Honeywell TG500A. Clear plastic w/ring base, lock and keys.
NIGHT SETBACK THERMOSTAT. Honeywell T822. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. 803005180
802005426
060684501
ADAPTER PLATE FOR T874/Q674 THERMOSTATS. Allows for horizontal thermostat to be mounted on a vertical junction box
OVERRIDE TIMER - 1 HOUR. OVERRIDE TIMER - 6 HOUR.
802007673
802005718802005717802005716
Description Part Number
STANDARD SUPPLY OR RETURN HOSE. Rubber hose with MPT 2' long, 1/2" I.D. 802025396 swivel hydraulic fittings on each end. Order two per unit. 3' long, 1/2" I.D. 802025397 FIRE RATED SUPPLY OR RETURN HOSE. Stainless steel, braided 2' long, 1/2" I.D. 802025593 hose with one MPT and one MPT swivel fitting. Order 2 per unit. 3' long, 1/2" I.D. 802025594 CONDENSATE HOSE ASSEMBLY. Requires trap by others. Order Clear plastic, 38" long 060687701 one per unit. Fire rated, 24" long 060688801 Includes fitting to be soldered on unit. Fire rated, 36" long 060688802 BALL VALVE. Combination shutoff and balancing valve with memory 1/2" FPT 802026097 stop. Order two per unit.
Description Part NumberHoses & Valves
Description Part Number 2" THICK THROWAWAY FILTER. Fits into 2" thick filter rack. Must order in multiples of 12. 060687106 1" THICK THROWAWAY FILTER. Replacement for standard filter. Must order in multiples of 12. 060604805 1" THICK CLEANABLE FILTER. Must order in multiples of 12. 060687006 2" THICK PLEATED FILTER, 35% EFFICIENT. Must order in multiples of 12. 060759804 RETURN AIR DUCT COLLAR & TWO INCH FILTER RACK. 060917401
Thermostat Accessories
Filters & Filter Components
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 7
Field Installed Accessories
LOGIC LINK II WITH BOILERLESS SYSTEM. Incorporates both Logic Link and Boilerless System control in one package. Includes ACO stat and subbase, and EWT sensor. Requires 24 volt AC external power source.
SHUTDOWN RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. For shutdown of the unit from an external 24 volt AC power source. Relay mounts at control box. 061019403
802005728
802007881
NIGHT SETBACK RELAY KIT FOR ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from an external 24 volt AC power source. Relay mounts at control box. Operation requires ACO stat with built-in NSB or a separate NSB stat. NIGHT SETBACK/DEMAND CONTROL RELAY KIT - ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source (3 total wires required). Relay mounts at control box, operation requires ACO stat with built-in NSB or separate NSB stat. RANDOM START RELAY - ELECTROMECHANICAL CONTROL. UNITS. Time delay relay to delay compressor startup when coming off night operation and to not allow all units to start at the same time.
115, 208/230, 265V
460, 575V
AUXILIARY RELAY. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate. BOILERLESS SYSTEM KIT. Must be Mark IV control unit. Includes electronics and sensor to lock out compressor operation at 50o F to 60o F EWT and provide SPNO contacts to a field supplied electric heater control system. LOGIC LINK II. Must be Mark IV control unit. Includes electronics, ACO stat and subbase for adjustable night setback and setup and compressor only shutdown (demand control/load shed) from a 24 volt AC external power source. Also includes 1 hour override control at the thermostat.
MULTIPLE UNIT CONTROL PANEL. Allows master unit to be controlled by any thermostat. Slave units "follow" with paralleled operation. Not recommended with Boilerless System.
060844701
803005260
803005073
802005496
802005498
803005159
859002819
CONDENSATE OVERFLOW SAFETY SWITCH - ELECTROMECHANICAL CONTROL UNITS. Float switch in drain pan to shut down compressor operation when pan fills.
060845001(NLA)
060846001(NLA)
Master & 1 Slave
Master & 3 Slaves Kit
MOTORIZED VALVE. Includes prewired valve/operator, 3 foot conduit assembly with leads and quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum operating pressure. Requires control relay. See below.
059004354
060977401
CONTROL RELAY FOR MOTORIZED VALVE.
1/2" FPT
INTERFACE KIT. For other electronic or DDC controlIers.
061047701Heat, Cool & Fan Ctrl
Heat, Cool & Fan Ctrl& Fault Relay
061047801
NLA = Part Numbers 060845001 & 060846001 are no longer available as a kit. Individual parts may be available.
Description Part NumberUnit Accessories
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 8
3
4
5
6
10
12
1
11
8
2
7
DiagramRefrigeration Circuit
TO WATER REGULATING VALVE (OPTION)
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 9
Bub.Num.
Description
PartNumber
Refrigeration Circuit
1 Compressor 802003261 1 1 Compressor 802003265 1 1 1 Compressor 802003266 1 1 Compressor 802003263 1 1 1 Compressor 802003264 1 1 1 Compressor 802003262 1 1 Compressor 060703202 1 1 1 Compressor 802003431 1 1 Compressor 060703201 1 1 1 Compressor 802003427 1 N/S Compressor Overload 802003267 1 N/S Compressor Overload 802003268 1 1 N/S Compressor Overload 802003269 1 N/S Compressor Overload 802003272 1 1 1 1 N/S Compressor Overload 802003270 1 N/S Compressor Overload 060703212 1 1 N/S Compressor Overload 802003433 1 N/S Compressor Overload 060703211 1 1 N/S Compressor Overload 802003184 1
N/S Capacitor, Compressor 25 MFD 370V 802007847 1 1 1 1 N/S Capacitor, Compressor 15 MFD 370V 802007844 1 1 1 1 1 1 1 1 1 N/S Capacitor, Compressor 35 MFD 370V 802007849 1 N/S Capacitor, Compressor 15 MFD 440V 802007852 1 N/S Bracket, Capacitor 050010570 1 1 1 1 1 1 1 1 1 1 N/S Nut, Flanged 802012035 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N/S Grommet 4 802007329 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Grommet 5 802003436 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Sleeve 4 802003114 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Washer, Retainer 5 802003437 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spring 5 802003438 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Washer 5 802003439 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Mounting Plate 802003045 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Spring, Mounting Plate 802003050 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Water Regulating Valve 2,15 802026194 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Water Regulating Valve 3,15 802026200 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
012007
Components
009
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
N/S = Not shown on diagram 2 VWH, VWG only. 3 VWW only. 4 Used only on Standard Construction units. 5 Used on all Extra Quiet Construction units.15 Only used on units with Water Regulating Valve option.
Continued on next page.
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 10
N/S = Not shown on diagram1 VWH, VWG only.2 VWW only.3 VWH, VWW only.
ComponentsRefrigeration Circuit
Bub.Num.
Description
PartNumber
2 Coaxial Coil Copper 060601401 1 1 1 1 1 2 Coaxial Coil Cupronickel 060601402 1 1 1 1 1 2 Coaxial Coil Copper 060601501 1 1 1 1 1 2 Coaxial Coil Cupronickel 060601502 1 1 1 1 1 2 Coaxial Coil Copper 060601601 1 1 1 1 1 2 Coaxial Coil Cupronickel 060601602 1 1 1 1 1
3 Fin Tubular Coil 060914901 1 1 1 1 1 3 Fin Tubular Coil 060914401 1 1 1 1 1 3 Fin Tubular Coil 060914301 1 1 1 1 1
4 Capillary (38.5 x .064 x .125) 060694703 1 1 1 1 1 4 Capillary (32.5 x .064 x .125) 060694702 1 1 1 1 1 4 Capillary (25 x .054 x .106) 060634703 1 1 1 1 1
5 Strainer 060628802 1 1 1 1 1
6 Reversing Valve 060724101 1 1 1 1 1 1 1 1 1 1 6 Reversing Valve 802026202 1 1 1 1 1 7 Solenoid, Reversing Valve 1 802026121 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
8 Switch, Hi Pressure 802005813 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
10 Thermostat, Low Temp Cutout 2 802005724 1 1 1 1 1 10 Thermostat, Low Temp Cutout 3 060863701 1 1 1 1 1 10 Thermostat, Low Temp Cutout 802005724 1 1 1 1 1 1 1 1 1 1 11 Speed Clip, Thermostat 802017208 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
12 Accumulator 3 802025542 1 1 1 1 1 1 1 1 1 1 12 Accumulator 3 060721601 1 1 1 1 1 N/S Drain Pan 060914101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
012007 009
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 11
Fan and Housing Assembly
Bub.Num.
Description
PartNumber
15 Motor 1/20 HP 060633804 1 1 15 Motor 1/20 HP 060633801 1 1 1 1 15 Motor 1/20 HP 060633802 1 1 15 Motor 1/20 HP 060633803 1 1 15 Motor 1/8 HP 060631004 1 15 Motor 1/8 HP 060631001 1 1 15 Motor 1/8 HP 060631002 1 15 Motor 1/8 HP 060631003 1 16 Capacitor 4 MFD, 370V 802007004 1 1 16 Capacitor 2 MFD, 370V 802007008 1 1 1 1 1 1 16 Capacitor 2 MFD, 440V 037516407 1 1 1 1 16 Capacitor 5 MFD, 440V 037516403 1 16 Capacitor 3 MFD, 440V 037516401 1 1 17 Bracket 850010570 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 18 Blower Housing Weldment 060699606 1 1 1 1 1 1 1 1 1 1 18 Blower Housing Weldment 060699602 1 1 1 1 1 19 Inlet Ring 060629101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 Wheel, Blower 060627401 1 1 1 1 1 1 1 1 1 1 20 Wheel, Blower 060628001 1 1 1 1 1 21 Protector, Terminal 802007316 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Cabinet/Chassis components 1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
012007 009
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
Cabinet/Chassis Components
15 20
16 21
19
17
18
N/S = Not shown on diagram.1 Contact Daikin with unit model and serial number for part numbers on Sheet Metal components.
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 12
Control BoxAccessory & Standard Control Layout
50HZ TERMINAL BLOCK & BRACKET
STANDARD CONTROL
27
22
37
40 42
41
23
29
28
43
ACCESSORY CONTROL
39
30 36
35
31
34 32
11
10
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 13
Control BoxMicroTech Control Layout
27
22
44
31
23
26
24
25
38
43
33 34 32
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 14
1 = Electromechanical Control units only. (Units with Model No. Digit 8 = E).2 = MicroTech Control units only. (Units with Model No. Digit 8 = C).3 = Mark IV Control units only. (Units with Model No. Digit 8 =M).
N/S = Not shown on diagram.
ComponentsControl Box
Bub.Num.
Description
PartNumber
22 Barrier, Control Box 060816201 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 22 Barrier, Control Box 2 060981901 1 1 1 1 1 1 1 1 1 1 1 1 23 P.C. Board, Mark IV 3 060638802 1 1 1 1 1 1 1 1 1 1 1 1 23 Circuit Board, Electromechanical 1 060679201 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 23 Circuit Board, Microtech 2 060959401 1 1 1 1 1 1 1 1 1 1 1 1 N/S Sensor Assembly, Temperature 2 060988402 1 1 1 1 1 1 1 1 1 1 1 1
24 Block, Terminal, 3-Pole 2 049759001 2 2 2 2 2 2 2 2 2 2 2 2 25 Block, Terminal, 4-Pole 2 049759002 1 1 1 1 1 1 1 1 1 1 1 1 26 Block, Terminal, 5-Pole 2 049759003 1 1 1 1 1 1 1 1 1 1 1 1
27 Panel, Mounting, PC Board 060981601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 27 Panel, Mounting, PC Board 2 060981701 1 1 1 1 1 1 1 1 1 1 1 1
28 Stand-Off 2 802028130 1 1 1 1 1 1 1 1 1 1 1 1 28 Stand-Off 3 802028130 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 28 Stand-Off 1 802028130 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
29 Nut, Nylon 2 802012415 1 1 1 1 1 1 1 1 1 1 1 1 29 Nut, Nylon 3 802012415 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 29 Nut, Nylon 1 802012415 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
30 Control Box 060981401 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 31 Screw, Tapping 033153700 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 N/S Washer, Cupped 030388700 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
**Must Verify Vendor Number Before Ordering** 32 Contactor, Compressor 20A 802005653 1 1 1 32 Contactor, Compressor 20A 803005193 1 1 1 1 1 1 1 1 32 Contactor, Compressor 20A 802005655 1 1 1 32 Relay, Compressor 2 24A 060949501 1 1 1 1 1 1 1 1 1 1 1 1
33 Board, Terminal 2 802007090 1 1 1 1 1 1 1 1 1 1 1 1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
012007 009
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
Continued on next page.
WSHP; VWH,VWG,VWW 007-012 Vintage A Rev. A 08/17 RPL 7000265 / Page 15
1 = Electromechanical Control units only. (Units with Model No. digit 8 = E). 2 = MicroTech Controller units only. (Units with Model No. digit 8 = C). 3 = Mark IV Control units only. (Units with Model No. digits 8 = M). 4 = Only on units with Random Start Relay Option. 5 = Only on units with Shutdown Relay Option. 6 = Only on units with Night Setback Option. 7 = Only on units with Demand Control Option. 8 = Only on units with Auxiliary Relay Option & without MicroTech Controller.
N/S = Not shown on diagram
ComponentsControl Box
Bub.Num.
Description
PartNumber
34 Relay, Fan 803005132 1 1 1 34 Relay, Fan 2 060949501 1 1 1 1 1 1 1 1 1 1 1 1 35 Relay, Random Start 1,4 802005496 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
N/S Relay, Shutdown 1,5 24V 061019403 1 1 1 1 1 1 1 1 1 1 1 1
36 Relay, Night Setback 1,6 802005728 1 1 1 1 1 1 1 1 1 1 1 1 36 Relay, Demand Control 1,7 802007881 1 1 1 1 1 1 1 1 1 1 1 1
37 Relay, Auxiliary 8 24V BD 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Timed Output 2 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Boilerless System 2 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Fresh Air Damper 2 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Motorized Valve 2 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 1 N/S Suppressor / Diode Assy. 2 061073402 1 1 1 1 1 1 1 1 1 1 1 1
39 Mount, Terminal Block 061131001 1 1 1
40 Terminal Block 802007432 2 2 2
41 End, Terminal Block 802007431 1 1 1
42 Terminal, Lug 802007744 1 1 1
43 Transformer 120V - 24V 060630801 1 1 1 43 Transformer 208/230V - 24V 060614101 1 1 1 1 1 1 1 1 1 43 Transformer 265V - 24V 060630701 1 1 1
44 Transformer 2 24V 060949301 1 1 1 1 1 1 1 1 1 1 1 1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
012007 009
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
115/
60/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
Critical Daikin Applied OEM PartsAre What Your HVAC Unit Needs!
7000265 Rev. A 08/2017 CPL Page 1 of 1
AAF Vertical WSHPVWH, VWG, VWW
007 - 012 Vintage A
Critical Components Unit Sizes Voltage Part Number
ControlControl Board, Electromechanical ALL ALL 060679201Control Board, Mark-IV ALL ALL 060638802Control Board, MicroTech ALL ALL 060959401
CompressorCompressor 007 115/60/1 802003261Compressor 007 208/230/60/1 802003265Compressor 007 265/60/1 802003266Compressor 007 230/50/1 802003264Compressor 009 115/60/1 802003262Compressor 009 208/230/60/1 802003263Compressor 009 265/60/1 802003264Compressor 009 230/50/1 060703202Compressor 012 115/60/1 802003431Compressor 012 208/230/60/1 802003201Compressor 012 265/60/1 060703202Compressor 012 230/50/1 802003427
Blower MotorMotor, 1/20HP 007, 009 115/60/1 060633804Motor, 1/20HP 007, 009 208/230/60/1 060633801Motor, 1/20HP 007, 009 265/60/1 060633802Motor, 1/20HP 007, 009 230/50/1 060961903Motor, 1/8HP 012 115/60/1 060631004Motor, 1/8HP 012 208/230/60/1 060631001Motor, 1/8HP 012 265/60/1 060631002Motor, 1/8HP 012 230/50/1 060631003
Fan Housing and Wheel Blower Housing 007, 009 N/A 060699606Blower Housing 012 N/A 060699602Wheel, Blower 007, 009 N/A 060627401Wheel, Blower 012 N/A 060628001
Sensor Sensor, Temperature Assy ALL N/A 060988402