vrf plus 2011 catalog
TRANSCRIPT
VRFAPPLIED COMMERCIAL AIR CONDITIONING
TM
2
VRF
PLU
S •
WH
O IS
CO
MFO
RTS
TAR
?w
ww
.com
fort
star
usa.
com
who is ComfortStar?
VRF PlusComfortStar’s VRF Plus series constitutes an advanced, reliable and cost-effective HVAC system, intended for large-scale commercial applications. Driven by cutting-edge Inverter compressor technology at its heart, and engineered for maximum cooling performance, it will meet the comfort demand of large buildings, in several different application types, at the highest energy-efficiency levels.
Our manufacturing facilities hold renowned quality control certifications: ISO9001 and ISO14001.
VRF Plus is our 2nd generation Variable Refrigerant Flow product family, after the CMR Digital Scroll series introduced in 2008.
WHO IS COMFORTSTAR?ComfortStar is an American HVAC company established in 1999. Focused mainly on the residential end of the HVAC industry spectrum, it pioneered development of a full HVAC residential product line for the Latin American and North American markets, targeting maximum cost-efficiency and world-class results.
ComfortStar’s mission statement is to provide our customers with superior product quality and service. Through continuous improvement we will become lean and pass-on savings to our customers. Simplification of processes to ensure error-free transactions and on-time delivery has been an objective since the Company’s inception.
ComfortStar’s goal is to satisfy our customers by making their experience enjoyable, easy and convenient.
VRFAPPLIED COMMERCIAL AIR CONDITIONING
TM
3
VRF PLU
S • WH
O IS C
OM
FOR
TSTAR
?1-866-524-9898
CHILLED‐WATER SYSTEM TYPICAL LAYOUT
COOLING TOWER
Additional System Larger Components Required
INDOOR UNITS
Piping
PUMPINDOOR UNITS
PUMP
CHILLERValuable commercial
space used as machine roommachine room
WHy VRF?The characteristics of Variable Refrigerant Flow systems pose it as an alternative to traditional chilled water systems. Consider-ing that HVAC systems for commercial buildings are subject to part-loading below 3/4 of their design capacity, during the major-ity of their operational time, VRF’s major highlight is its superior part-load energy efficiency nature.
Ease of installation, without the need of allocating valuable commercial space for machine rooms, is another significant benefit of VRF systems.
• Simple System Lay-out• No Machine Room Needed• More Commercial Space
• Instead of distributing chilled water to air handling/fan coil units, VRF systems distribute environmental-friendly refrigerant to each conditioned zone, where a direct expansion indoor coil unit is installed; hence, no cooling tower circuit is required or additional pumping equipment, and a simpler system lay-out can be accomplished.
• Easy installation, no duct work, no large distribution fans, no water pumps and much smaller piping to save valuable space.
• Simple design, various types of indoor units and wide range of outdoor units to meet your existing building/new construction project requirements and constraints.
• Ultra high-efficiency in part-load, conditioning only the zones being occupied and therefore boosting energy savings.
• Easy equipment transportation; compact outdoor unit design allows for transportation through standard-sized elevators.
• Minimum potential of HVAC down time with modular outdoor units.
• Easy maintenance and service.
VRF has been widely used in a broad range of applications that includes: hotels, malls, office buildings, conference facilities, nursing homes, residential multi-family households, restaurants, retail stores, schools, universities, etc.
VRF general benefits
400
COMMERCIAL APPLICATION PART‐LOAD DEMAND
295
338350
ar 295
243
216250
300
rs in
a Ye
161150
200
er of H
our
42
118102
44
100
Num
be23
42 44
0
50
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
Partial Building Load
COMMeRCIAL APPLICATIOn PART-LOAd deMAnd
CHILLed-WATeR SySTeM TyPICAL LAyOUTVRF SYSTEM LAYOUT
INDOOR VRF UNITS
•Simple Layout•Simple Layout.•Less System Components.•Smaller Piping.N M hi R•No Machine Room.•More Commercial Space.
OUTDOOR VRF UNIT
VRF SySTeM LAyOUT
4
VRF
PLU
S •
FeA
TUR
eS &
Ben
eFIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS & BeneFITS VRF Plus• Environmental-friendly R-410a• Modular outdoor units that can be combined up to a 52-ton system• Available in: 230V-3 Phase-60 Hz, 380V-3 Phase-60 Hz, 380V-3 Phase-50 Hz• Heat Pump and Heat Recovery Systems• Inverter Technology Compressor and DC motor• CFD optimized heat exchange• Outstanding ranges of ambient temperature operation: Cooling from 23°F To 118°F (-5°C to 48°C) and Heating from -4°F to 81°F (-20°C to 27°C)• Supports long piping distances up to 574 ft (175m)• Low noise levels• High-static capable outdoor units• Increased comfort level with reduced temperature fluctuation• Individual zoning control with On-Demand Heating and Cooling• Master-Slave switching logic for extended life-span• Intelligent indoor unit auto-addressing• Compatible with control gateways such as LonWorks and BACnet• Remote monitoring technology
features & benefits
5
VRF PLU
S • FeATUR
eS & B
eneFITS
1-866-524-9898
FLeXIBLe CAPACITy RAnGeComfortStar VRF Plus offers superlative flexibility in capacity range with modular outdoor systems. 5 basic single-cabinet modules: 8HP (7-ton), 10HP (8-ton), 12HP (9.5-ton), 14HP (11.5-ton) and 16HP (13-ton).
Basic modules can be combined to comprise large-scale systems up to 64HP (52-ton) capacity. Remarkable capacity range from 8HP (7-ton), to 64HP (52-ton).
Basic modules can be combined to comprise large-scale systems up to 64HP (52-ton) capacity.
Heat Pump
Heat Recovery
SIMULTAneOUS HeATInG And COOLInG on different zones is supported with our Heat Recovery systems. Conventional Heat Pump system also available.
The principle of heat recovery consists on releasing the heat carried out of a cooling zone, into a zone with a demand for heating. Branch selectors have to be added to the piping network to be able to accomplish this energy recycling process, which allows for a power consumption drop (of up to 45%*), under simultaneous cooling/heating conditions, with respect to equivalent but separate heating/cooling systems.
* 45% power consumption drop based on following example: 6-ton Heating + 6-ton Cooling individual systems vs.12-ton Heat Recovery system operating at conditions: A) Cooling Zones: 67ºF WB indoor and 95ºF WB outdoor. B) Heating Zones: 70°F DB indoor and 47° DB outdoor.
heat pump & heat recoveryoptions
6
VRF
PLU
S •
FeA
TUR
eS &
Ben
eFIT
Sw
ww
.com
fort
star
usa.
com
CUTTInG-edGe TeCHnOLOGy TO THe COReThe exceptional performance and energy-efficiency ratings depicted by ComfortStar VRF Plus are due to implementation of cutting-edge technology on the essential system components. Improvements with respect to the former VRF Digital Scroll line include High-Efficiency DC Motors, DC Inverter- Driven Compressors, CFD-Optimized coils and Aero-Dynamically Enhanced Fans.
InVeRTeR-dRIVe allows frequency/capacity modulation of the compressor down to 30% of its rated capacity. The DC Motor winding of the compressor is centralized type, in contrast to dis-tributed winding, boosting compressor performance. 20% power consumption reduction with respect to Digital Scroll VRF modulat-ing compressors.
eXTenSIVe Computational Fluid Dynamics studies were conducted to optimize the heat exchange properties of the condenser coils and the Aero-dynamic performance of the condenser fans.
• Inner surface spiral rifling
• Packaged U-shape design; Ingenious flow-direction
• Larger surface area for increased heat-exchange
• Airflow increment and noise level drop
The dC Motor shifts through 18 different rotational speed levels. Rotational speed is adjusted in accordance to the running system load and pressure. Energy Consumption is minimized with respect to multiple-speed induction motors. It accounts for 40% savings with respect to Digital Scroll series condenser motors.
cutting edge technology
CFD optimized design for Condesing Coil.Larger (30%) heat exchange area; 10% Efficiency Increase.
Packaged U-Model Design.H d hili C i Al i Fi
Larger (30%) heat exchange area; 10% Efficiency Increase.Packaged U-Model Design.
Hydrophilic Coating on Aluminum Fins.Internal Spiral Rifled Copper Tubing, for Enhnaced Turbulence.
CFD-Optimized 3D Turbo Fan.CFD-Optimized 3D Turbo Fan.Large Diamamter Design Allows Higher (10%) Airflow and Lower
(2dB less) Noise Level(2dB less) Noise Level.
1400LOAD‐REVOLUTION CURVE
1200According to the running load and system pressure, the speed of DC fan is adjusted to achieve top
800
1000
j pperformance with minimum power
consumption.
600
800
RPM
400AC Multi‐Speed Fan
200 DC Variable Vector Adjustment Fan
00 20 40 60 80 100
Load (%)
LOAd-ReVOLUTIOn CURVe
110
COMPRESSOR INTERNAL WINDING
100 Centralized Winding
Di t ib t d Wi di90
ficiency
Distributed Winding
80
pressor Eff
70
Comp
50
60
50
15 25 35 45 55 65 75 85 95Rotor Speed Rev per Second
COMPReSSOR InTeRnAL WIndInG
Brushless DC MotorCompact Design
50% Weight Reduction50% Weight ReductionSpecial-Design Scroll Spec a es g Sc o
for R-410a Centralized Winding on
StatorStatorMagnet Rotor ofMagnet Rotor of
Neodymium Material.Neodymium Material.
7
VRF PLU
S • FeATUR
eS & B
eneFITS
1-866-524-9898
HIGH eneRGy eFFICIenCyThe implementation of the most advanced technology in ComfortStar VRF Plus leads towards elevated efficiency ratings. Sound Engineering dedicated in the research and development of ComfortStar VRF Plus yielded average increases of 18% EER and 25% COP, with respect to Digital Scroll VRF by ComfortStar.
HIGH-PReCISIOn COnTROL of refrigerant flow volume by means of double Electronic Expansion Valves capable of 960 adjustment positions on all outdoor units. Improved refrigerant distribution/expansion with EEV on all indoor units capable of adopting 480 different positions.
energy efficient
Energy Efficiency Ratios from 3.21 to 4.49Average EER 3.67
4.50 4.39
COP
3 50
4.004.14 4.17
4.023.913.60
3.39
2 50
3.00
3.50 3.39
3.21 3.203.15
1 50
2.00
2.50
0 50
1.00
1.50
0.00
0.50
8HP (7‐ton)10HP (8 t )
VRF Plus
Digital Scroll
10HP (8‐ton)12HP (9.5‐ton)
14HP (11.5‐ton)16HP (13‐ton)
COP
Coefficients of Performance from 3.91 to 4.39Average COP 4.12
4.50 4.29
EER
3 50
4.00 3.89
3.70
2 50
3.00
3.503.25
3.21
3.183.09
3.01 3.153.08
1 50
2.00
2.50
0 50
1.00
1.50
0.00
0.50
8HP (7‐ton)10HP (8 t )
VRF Plus
Digital Scroll
10HP (8‐ton)12HP (9.5‐ton)
14HP (11.5‐ton)16HP (13‐ton)
eeR
Capacity output adjustment: 30% - 100% capacity output adjustment:
Refrigerant flow volumn adjustment: Double EXV with 960 steps adjustment in outdoor unit:
Refrigerant distribution control: Each indoor unit adopts one EXV with 480 steps adjustment
Compressor output
100%
30%
Key TeCHnOLOGy
8
VRF
PLU
S •
FeA
TUR
eS &
Ben
eFIT
Sw
ww
.com
fort
star
usa.
com
SySTeM ReLIABILITy is also increased by automatic start-up of available slave outdoor units, upon failure of a running slave outdoor unit, which subsequently enters a stand-by mode to prevent further system errors.
LOW-nOISe OPeRATIOnVRF Plus features quiet operation functions that reduce the noise levels as much as 46 dB(A) during non-peak load conditions. The system monitors ambient temperature changes and records highest point during the day. The wait time from peak temperature to trigger quiet mode operation can be set; the length of operation in this mode can also be set.
features & benefitsVRFpluS
MAXIMIZed LIFe-SPAn And ReLIABILITyComfortStar VRF Plus modular systems adopt Superior Master/Slave control logic to maximize the life-span of all compressors in the system.
Role Selection capability allows random assign-ment of the Master outdoor unit and it also allows manual assignment of a specific outdoor unit to always cycle in the Master role.
An innovative compressor cycling logic among outdoor units, where inverter compressors are sequentially started prior to fixed-speed compres-sors, favors compressor lifetime and part-load efficiency.
70120%
LOW‐NOISE OPERATION
60100%
40
5080%
[dB]
%] 9 hours Low‐Noise Cycle
30
4060%
ise Level
Load
[%
8 hours after critical load
9 hours Low Noise Cycle
20
20%
40% No
Cooling Load
Noise Level
0
10
0%
20%
8:00 AM 12:00 PM 4:00 PM 8:00 PM 12:00 AM 4:00 AM 8:00 AM
LOAd-ReVOLUTIOn CURVe
MASTeRSLAVe 1 SLAVe 1
INV FIX 1 FIX 1 INV FIX 1 FIX 1 INV FIX 1 FIX 1
No. 1 No. 2 No.3No. 1 No. 2 No.3No. 1 No. 2 No.3
MASTER SLAVE 1 SLAVE 2
STDINV STD STDINV STD STDINV STD
U F il f i l d l hUpon Failure of a running slave module, the failed module enters Stand‐by Mode and
triggers start‐up of available slave modules.
9
VRF PLU
S • FeATUR
eS & B
eneFITS
1-866-524-9898
HIGH eXTeRnAL STATIC PReSSUReAdjustment setting of the fan static pressure provides additional alternatives for outdoor unit installation conditions.
Standard setting of motor static pressure can be changed from 0 to 0.08 in W.C. (0 Pa to 20 Pa) and even customized in a range of 0.08 to 0.33 in W.C. (20 Pa to 82 Pa) to conform with pressure loss characteristics of horizontal-discharge ductwork/hood accessories.
LOnG-PIPInG & HIGH eLeVATIOnComfortStar VRF Plus is suitable for applications where long-piping distance is required. The maximum allowable piping constraints are listed following:
Total piping distance: 1640 ft (500m)Longest run to furthest indoor unit: 574 ft (175m)Height Difference between Outdoor and Indoor: 230 ft (70m)—(Outdoor Unit located above)Height Difference between Outdoor and Indoor: 131 ft (40m)—(Outdoor Unit located below)Height Difference between Indoor Units: 50 ft (15m)
WIde OPeRATInG AMBIenT RAnGe The technology comprising VRF Plus favors operation in a very wide range of ambient condi-tions. Hence, our systems can endure sustained cooling operation at high-temperatures (up to 118°F/48°C), while at the same time cooling can be delivered at relatively low-ambient conditions.
0 in W.C. (0 Pa)Standard
0.08 in W.C. (20 Pa)Optional
0.08 to 0.33 in W.C. (20-81.8 Pa)Customized
features & benefits
Outdoor Units on Top Floor
Heigh Longest R
u
ht Difference
Height D
iffeLevels:5 0 un:574 ft.
e Outdoor/In
renceIndoo
0 ft. [15m]
[175m]
door:230 ft
or
t. [70m]
Furthermost Floor
140 °F60 °CAMBIENT TEMPERATURE RANGE
120 °F
40 °C
50 °C118°F [48°C]
80 °F
100 °F
30 °C
40 C
81°F [27°C]
60 °F10 °C
20 °C COOLING
20 °F
40 °F
‐10 °C
°C HEATING23°F [‐5°C]
°F‐20 °C
10 C
‐4°F [‐20°C]
[ ]
‐20 °F‐30 °C
AMBIenT TeMPeRATURe RAnGe
10
VRF
PLU
S •
FeA
TUR
eS &
Ben
eFIT
Sw
ww
.com
fort
star
usa.
com
MOde COnFLICT PReVenTIOnUnlike Heat Recovery systems, the heat pump systems do not support simultaneous cooling and heating of different zones; hence it is vital to design them with capability to prevent malfunctions due to mode conflict. ComfortStar VRF Plus heat pump systems can be set in 5 different mode priority states in order to avoid such malfunction. Heating or Cooling can be prioritized one mode over the other, or the system may be set to operate on a first-call mode basis.
OIL ReTURnIn order to maximize compressor lifetime, a special oil return logic is programmed to ensure constant lubrication. After 8 hours of operation the oil return mode starts. Indoor fan is stopped for stand-by units. Indoor fan resumes operation if the unit is on the cooling mode and it is controlled by the Anti-Freezing function if the indoor unit is set in the heating mode.
HeatingHeatingOnly
First indoor unit priority
Heating priority
Coolingpriorityunit priority p y priority
CoolingOnly
AUTO AddReSSInGElectrical wiring of indoor units is done easily and no manual ID addressing action is necessary with Comfort-Star VRF Plus systems. The system is programmed with Intelligent Auto-Addressing feature that reduces the overall installation/set-up time.
eASe OF SeRVICeSelf-Diagnostics and Operating Parameters History are among the characteristics that favor Serviceability of ComfortStar VRF Plus systems. Specialized software is also available for detailed monitoring of the operation history of the system on a service call. Compressor proximity to the front panel makes it easy for an eventual replacement.
features & benefits
UPS
40# 41# 42#
Indoor Units Central ControllerSoftDog
Indoor Units Central Controller
NETWORK CONTROL
00# 01# 02#Central Controller
O td U it
RS485‐232
Outdoor Units Central Controllers
11
VRF PLU
S • OU
TdO
OR
Un
ITS1-866-524-9898
MOdeL # nOMenCLATURe
CMRV H 86 3 410 ComfortStar VRF Plus H= heat Pump BTU X1000 3= 60 hz, 3 phase, 230V Refrigerant Type R=Heat Recovery 4= 60 hz, 3 phase, 380V-415V Omitted = Cooling only 6 = 50hz, 3 phase, 380V-415V
outdoor units
* Testing Conditions for the above table of technical specifications are:1. Cooling Conditions: Indoor Temperature 81°F DB (27°C), 60°F WB (19°C). Outdoor Temperature 95°F DB (35°C). 16.4 ft total piping length.2. Heating Conditions: Indoor Temperature 68°F DB (20°C), 44.6°F WB (15°C). Outdoor Temperature 42.8°F DB (7°C). 16.4 ft total piping length.3. Sound level: Anechoic chamber conversion value; measured 3.28ft (1m) away from the unit at a height of 4.27ft (1.3m).
technical specifications
Model CMRVH- 86-3-410
CMRVH- 96-3-410
CMRVH- 114-3-410
CMRVH- 137-3-410
CMRVH- 154-3-410
cooling capacity (BTU)
HP 8.0 10.0 12.0 14.0 16.0
BTU/H 85,982.4 95,536 114,302 136,480 153,540
cooling input power KW 5.88 7.2 9.05 12.3 14
heating capacity BTU/H 92,124 107,478 127,950 153,540 170,600
heating input power KW 6.15 7.6 9 11.2 12.8
operation range cooling
F 23F to 118F 23F to 118F 23F to 118F 23F to 118F 23F to 118F
C -5C to 48C -5C to 48C -5C to 48C -5C to 48C -5C to 48C
operation range heating
F -4F to 81F -4F to 81F -4F to 81F -4F to 81F -4F to 81F
C -20C to 27C -20C to 27C -20C to 27C -20C to 27C -20C to 27C
power V-Ph-Hz 220-3-60 220-3-60 220-3-60 220-3-60 220-3-60
sound pressure level dB(A) 57 57 58 60 60
airflowCFM 6,474 6,474 7,357 8,829 8,829
M3/H 11,000 11,000 12,500 15,000 15,000
max elevation ft (m) 230 ft. (70 meters) if outdoor unit higher than indoor unit, 131 ft. (40 meters) if outdoor unit lower than indoor unit
actual pipe length ft (m) 492 (150) 492 (150) 492 (150) 492 (150) 492 (150)
Equivalent pipe length ft (m) 574 (175) 574 (175) 574 (175) 574 (175) 574 (175)
total pipe length ft (m) 1640 (500) 1640 (500) 1640 (500) 1640 (500) 1640 (500)
max. no of indoor units 13 16 16 16 20
matching capacity ratio % 50-130 50-130 50-130 50-130 50-130
net weight lb (kg) 584 (265) 584 (265) 672 (305) 772 (350) 772 (350)
gross weight lb (kg) 617 (280) 617 (280) 716 (325) 816 (370) 816 (370)
net dimension (WxHxD)
in 39x64x31 39x64x31 51x64x30 51x64x30 51x64x30
mm 980x1615x800 980x1615x800 1290x1615x750 1290x1615x750 1290x1615x750
packing dim. (WxHxD)
in 41x70x34 41x70x34 49x70x34 49x70x34 49x70x34
mm 1044x1790x865 1044x1790x865 1254x1790x860 1254x1790x860 1254x1790x860
loading qty per 20’/40’/40’’HQ 12/26/26 12/26/26 10/22/22 10/22/22 10/22/22
12
VRF
PLU
S •
OU
TdO
OR
Un
ITS
ww
w.c
omfo
rtst
arus
a.co
m
HIGH-CAPACITy COMBInATIOnSComfortStar VRF Plus offers 5 basic modules that can be combined to form high-capacity sizes. Some sizes can be accomplished with different selection of modules that can favor price, installation area or efficiency ratings. Refer to the table below for criteria of selection.
outdoor units
HP Cost Area Efficiency
18 8+10 8+10 8+10
20 10+10 10+10 10+10
22 10+12 10+12 10+12
24 12+12 8+16 10+14
26 12+14 10+16 10+16
28 12+16 12+16 12+16
30 14+16 14+16 14+16
32 16+16 16+16 16+16
34 10+12+12 10+10+14 10+10+14
36 12+12+12 10+10+16 10+10+16
38 12+12+14 10+12+16 10+12+16
40 12+12+16 10+14+16 10+14+16
42 12+14+16 10+16+16 10+16+16
44 12+16+16 12+16+16 12+16+16
46 14+16+16 14+16+16 14+16+16
48 16+16+16 16+16+16 16+16+16
50 12+12+12+14 8+10+16+16 8+10+16+16
52 12+12+12+16 10+10+16+16 10+10+16+16
54 12+12+14+16 10+12+16+16 10+12+16+16
56 12+12+16+16 8+16+16+16 10+14+16+16
58 12+14+16+16 10+16+16+16 10+16+16+16
60 12+16+16+16 12+16+16+16 12+16+16+16
62 14+16+16+16 14+16+16+16 14+16+16+16
64 16+16+16+16 16+16+16+16 16+16+16+16
priority criteria
13
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898 CMRVH 24 D1 1 410 ComfortStar VRF Plus BTU X1000 C1= One way cassette 1= 60 hz, 1 phase, 230V Refrigerant Type C4C= compact 4-way cassette 5= 50hz, 1 phase, 220V C4=Regular 4-way cassette D1=high static duct type D2= Median static duct type D3=Low static duct type U= Universal mounted WX= wall mounted with EXV built in W= wall mounted without EXV built in FA= Floor standing type A FB =floor standing type B FC= flooring standing type C CO= console type OU=Outdoor air processing unit
indoorunitsindoor unit line up
Indoor unit capacity BTU
one way cassette • • • • •
compact 4-way cassette • • • •
regular 4-way cassette • • • • • • • • • •
high static duct type • • • • • • • • •
median static duct type • • • • • • • • • •
low static duct type • • • • • •
U= universal mounted • • • • • • • •
WX= wall mounted with EXV built in • • • • •
W= wall mounted without EXV built in • • • • •
FA= floor standing type A • • • • • • •
FB =floor standing type B • • • • • • •
FC= flooring standing type C • • • • • • •
CO= console type • • • •
OU=outdoor air processing unit • • •
6,100
24,20
0
12,20
0
34,12
0
7,500
27,20
0
15,30
0
38,20
0
9,500
30,70
0
19,10
0
48,00
0
55,00
0
68,20
0
85,30
0
96,00
0
14
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
1-way cassette
technical specifications
ModelCMRVH9C1
-1-410CMRVH12C1-
1-410CMRVH15C1-
1-410CMRVH19C1-
1-410CMRVH24C1-
1-410
capacityCOOLIng BTU/H 9,554 12,283 15,354 19,107 24,225
HEATIng BTU/H 10,918 13,648 17,060 21,496 27,296
power supply V-Ph-Hz 220-240-1-60
rated power W 50 50 70 73 85
air flowCFM 294 294 460 460 636
m3/h 500 500 780 780 1080
noise level dB(A) 30 30 35 35 35
refrigerant R410A
net dim.
body (WxHxD)
in 33x9x16 33x9x16 47x8x26 47x8x26 47x8x26
mm 850x235x400 850x235x400 1200x198x655 1200x198x655 1200x198x655
panel (WxHXD)
in 41x1x19 41x1x19 56x1/2x30 56x1/2x30 56x1/2x30
mm 1050x18x470 1050x18x470 1420x10x755 1420x10x755 1420x10x755
packing dim.
body (WxHxD)
in 43x12x20 43x12x20 54x10x31 54x10x31 54x10x31
mm 1080x310x510 1080x310x510 1380x265x775 1380x265x775 1380x265x775
panel (WxHXD)
in 40x7x21 40x7x21 59x4x34 59x4x34 59x4x34
mm 1120x172x540 1120x172x540 1500x110x870 1500x110x870 1500x110x870
net weight
body lb 55 55 75 75 75
kg 25 25 34 34 34
panellb 9 9 20 20 20
kg 4 4 9 9 9
body lb 62 62 90.5 90.5 90.5
gross weight
kg 28 28 41 41 41
panellb 15.5 15.5 26.5 26.5 26.5
kg 7 7 12 12 12
loading quanity 20’/40’/40’HQ 115/238/268 115/238/268 69/145/165 69/145/165 69/145/165
lineset
liquid inch 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’
Drainage pipe inch 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’
FeATUReS:• Capacity range: 9,000 ~ 24,000 btu/h (2.8kW ~ 7.1kW)• Body dimension, W×H×D: 9,000 ~ 12,000 btu/h: 33x9x16 in (2.8kW ~ 3.6kW: 850×235×400mm) 15,000 ~ 24,000 btu/h: 47x8x26 in (4.5kW~ 7.1kW: 1200×198×655mm)• Panel dimension, W×H×D: 9,000 ~ 12,000 btu/h: 41x1x19 in (2.8kW ~ 3.6kW: 1050×18×470mm) 15,000 ~ 24,000 btu/h: 56x1/2x30 in (4.5kW~ 7.1kW: 1420×10×755mm)• EXV is outside the body• Thickness is down to 8 in (for 15,000/19,000/24,000 btu/h unit only)—(198mm (for 4.5/5.6/7.1kW unit only)• Integrated with condensate pump, pumping head can be up to 30 in (750mm)
15
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
FeATUReS:• Capacity range: 7,500 ~ 15,000 btu/h (2.2kW ~ 5.6kW)• 360° air discharge • Body dimension, W×H×D: 22.6 x 10.2 x 22.6 in (575×260×575mm)• Panel dimension, W×H×D: 25.5 x 2 x 25.5 in (647×50×647mm)• EXV is outside the body• Reserved a hole for fresh air inlet• Integrated with condensate pump, pumping head can be up to 28 in (700mm)
compact 4-waycassette
technical specifications
ModelCMRVH7C4C-
1-410CMRVH9C4C-
1-410CMRVH12C4C-
1-410CMRVH15C4C-
1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354
HEATIng BTU/H 8,189 10,918 13,648 17,060
power supply V-Ph-Hz 220-240-1-60
rated power W 48 48 56 56
air FlowCFM 307 307 359 359
m3/h 522 522 610 610
noise level dB(A) 38 38 42 42
refrigerant R410A
net dimension
body (WxHxD)in 22.6x10.2x22.6 22.6x10.2x22.6 22.6x10.2x22.6 22.6x10.2x22.6
mm 575x265x575 575x265x575 575x265x575 575x265x575
panel (WxHXD)in 25.5x2x25.5 25.5x2x25.5 25.5x2x25.5 25.5x2x25.5
mm 647x50x647 647x50x647 647x50x647 647x50x647
packing dimension
body (WxHxD)in 26.6x11x26.6 26.6x11x26.6 26.6x11x26.6 26.6x11x26.6
mm 675x285x675 675x285x675 675x285x675 675x285x675
panel (WxHXD)in 27.8x4.5x27.8 27.8x4.5x27.8 27.8x4.5x27.8 27.8x4.5x27.8
mm 705x113x705 705x113x705 705x113x705 705x113x705
net weight
body lb (kg) 38.6 (17.5) 38.6 (17.5) 41.9 (19) 41.9 (19)
panel lb (kg) 6.6 (3) 6.6 (3) 6.6 (3) 6.6 (3)
gross weight
body lb (kg) 48.5 (22) 48.5 (22) 51.8 (23.5) 51.8 (23.5)
panel lb (kg) 11 (5) 11 (5) 11 (5) 11 (5)
loading quantity 20’/40’/40’HQ 288/624/684 288/624/684 288/624/684 288/624/684
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’
Drainage pipe inch 1’’ 1’’ 1’’ 1’’
16
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS:• Capacity range: 9,500 ~ 48,000 btu/h (2.8kW ~ 14kW)• Body dimension, W×H×D: 9,500 ~ 27,000:33x9x33 in (2.8kW~8.0kW:840×230×840mm) 30,000 ~ 48,000:33x12x33 in (9.0kW~14.kW:840×300×840mm)• Panel dimension, W×H×D: 37x2x37 in (950×46×950mm)• EXV is outside the body• Reserved a hole for fresh air inlet• Integrated with condensate pump, pumping head can be up to 30 in (750mm)• Four color panels to choose
4-way cassette
technical specifications
ModelCMRV H9C4- 1-410
CMRV H12C4- 1-410
CMRV H15C4- 1-410
CMRV H19C4- 1-410
CMRV H24C4- 1-410
CMRV H27C4- 1-410
CMRV H30C4- 1-410
CMRV H34C4- 1-410
CMRV H38C4- 1-410
CMRV H48C4- 1-410
capacityCOOLIng BTU/H 9,554 12,283 15,354 19,107 24,225 27,296 30,708 34,120 38,214 47,768
HEATIng BTU/H 10,918 13,648 17,060 21,496 27,296 30,708 34,120 37,532 42,650 51,180
power supply V-Ph-Hz 220-240-1-60
rated power W 90 90 90 90 115 115 160 160 160 180
air flowCFM 559 559 559 559 718 718 906 906 906 1089
m3/h 950 950 950 950 1220 1220 1540 1540 1540 1850
noise level dB(A) 35 35 35 35 39 39 43 43 43 44
refrigerant R410A
net dim.
body (WxHxD)
in 33x9x33 33x12x33
mm 840x230x840 840x300x840
panel (WxHxD)
in 37x2x37
mm 950x46x950
packing dim.
body (WxHxD)
in 38x10x38 38x12.5x38
mm 955x247x955 955x317x955
panel (WxHxD)
in 41x4x41
mm 1035x90x1035
net weight
body lb 52.9 53.1 56.7 57.3 57.8 57.6 70.3 70.6 70.8 70.8
kg 24 24.1 25.7 26 26.2 26.1 31.9 32 32.1 32.1
panellb 13.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2
kg 6 6 6 6 6 6 6 6 6 6
gross weight
body lb 66.1 66.4 69.7 70.1 69.9 70.1 85.1 85.3 85.1 85.1
kg 30 30.1 31.6 31.8 31.7 31.8 38.6 38.7 38.6 38.6
panellb 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8 19.8
kg 9 9 9 9 9 9 9 9 9 9
loading quantity 20’/40’/40’HQ
72/ 149/ 168
72/ 149/ 168
72/ 149/ 168
72/ 149 /168
72/ 149/ 168
72/ 149/ 168
48/ 102/ 122
48/ 102/ 122
48/ 102/ 122
48/ 102/ 122
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
drainage pipe inch 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’ 1-1/4’’
17
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
fan coil high-static
technical specifications
Model CMRV
H24D1- 1-410
CMRV H27D1- 1-410
CMRV H30D1- 1-410
CMRV H38D1- 1-410
CMRV H48D1- 1-410
CMRV H55D1- 1-410
CMRV H68D1- 1-410
CMRV H85D1- 1-410
CMRV H96D1- 1-410
capacityCOOLIng BTU/H 24,225 27,296 30,708 38,214 47,768 54,592 68,240 85,300 95,536
HEATIng BTU/H 27,296 30,708 34,120 42,650 54,592 61,416 76,770 88,712 107,478
power supplyV-
Ph- Hz
220-240-1-60
rated power w 246 378 490 490 521 944 1400 1400 1400
performance
air flowCFM 770 1039 1207 1207 1391 1918 2460 2460 2590
m3/h 1309 1765 2051 2051 2363 3259 4180 4180 4400
static pressure
in WC 0.24 0.28 0.28 0.28 0.36 0.36 0.78 0.78 0.78
pa 60 70 70 70 90 90 196 196 196
noise level dB(A)45/ 43/ 41
45/ 43/ 41
48/ 46/ 43
48/ 46/ 43
50/ 48/ 45
50/ 48/ 45
55 55 55
refrigerant Type R410A
net dim. WxHxD
in34 x16 x27
34 x16 x27
34 x16 x27
34 x16 x27
47 x16 x27
47 x16 x27
56 x20 x37
56 x20 x37
56 x20 x37
mm856 x400 x691
856 x400 x691
856 x400 x691
856 x400 x691
1200 x400 x691
1200 x400 x691
1425 x500 x928
1425 x500 x928
1425 x500 x928
packing dim. WxHxD
in43 x18 x30
43 x18 x30
43 x18 x30
43 x18 x30
56 x18 x30
56 x18 x30
59 x22 x38
59 x22 x38
59 x22 x38
mm1102 x450 x768
1102 x450 x768
1102 x450 x768
1102 x450 x768
1430 x450 x768
1430 x450 x768
1509 x570 x964
1509 x570 x964
1509 x570 x964
net weightlb 90 97 103.5 103.5 141 141 252 252 252
kg 41 44 47 47 64 64 114.5 114.5 114.5
gross weightlb 110 117 123.5 123.5 163 163 283 283 283
kg 50 53 56 56 74 74 128.5 128.5 128.5
quantity per 20’/40’/40HQ80/
164/ 193
80/ 164/ 193
80/ 164/ 193
80/ 164/ 193
63/ 128/ 140
63/ 128/ 140
31/ 63/ 79
31/ 63/ 79
31/ 63/ 79
Line set
liquid inch 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’
gas inch 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
Drainage pipe inch 1 1 1 1 1 1 1-1/4’’ 1-1/4’’ 1-1/4’’
FeATUReS:• Capacity range: 68,000/85,000/96,000 btu/h (20kW/25kW/28kW)• ESP: 0.78 in W.C. (196Pa)• Thickness: 20 in (500mm)• Newly design, easy for maintenance• Air intake from back with filter
18
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS:• Capacity range: 7,000 ~ 48,000 btu/h (2.2kW ~ 14kW)• ESP range: 0.12 ~0.4 in WC (30Pa ~ 100Pa)• Air outlet and inlet flange is standard• Reserved fresh air outlet hole• Optional condensate pump
fan coil medium-static
technical specifications
Model CMRV H7D2- 1-410
CMRV H9D2- 1-410
CMRV H12D2- 1-410
CMRV H15D2- 1-410
CMRV H19D2- 1-410
CMRV H24D2- 1-410
CMRV H27D2- 1-410
CMRV H30D2- 1-410
CMRV H38D2- 1-410
CMRV H48D2- 1-410
capac-ity
COOLIng BTU/H 7,506 9,554 12,283 15,354 19,107 24,225 27,296 30,708 38,214 47,768
HEATIng BTU/H 8,871 10,918 13,648 17,060 21,496 27,296 30,708 34,120 42,650 52,886
power supplyV-
Ph- Hz
220-240-1-60
rated power w 62 62 67 115 115 163 231 231 327 357
perfor-mance
air flowCFM 336 336 336 564 564 710 917 917 1198 1258
m3/h 570 570 570 958 958 1207 1558 1558 2036 2138
static pressure
in WC 0.04/0.12 0.08/0.2 0.16/0.32 0.16/0.4
pa 10/30 (optional)
10/30 (optional)
10/30 (optional)
10/30 (optional)
10/30 (optional)
10/30 (optional)
20/50 (optional)
20/50 (optional)
40/80 (optional)
40/100 (optional)
noise level dB(A) 32 32 36 36 36 36 35 35 38 39
refriger-ant Type R410A
net dim. WxHxD
in28 x8
x25
28 x8
x25
28 x8
x25
36 x8
x22
36 x8
x22
36 x8
x22
45 x11 x28
45 x11 x28
45 x11 x28
47 x12 x32
mm700 x210 x635
700 x210 x635
700 x210 x635
920 x210 x570
920 x210 x570
920 x210 x570
1140 x270 x710
1140 x270 x710
1140 x270 x710
1200 x300 x800
packing dim. WxHxD
in36 x11 x26
36 x11 x26
36 x11 x26
45 x11 x26
45 x11 x26
45 x11 x26
53 x14 x31
53 x14 x31
53 x14 x31
55 x15 x36
mm915 x290 x655
915 x290 x655
915 x290 x655
1135 x290 x655
1135 x290 x655
1135 x290 x655
1355 x350 x795
1355 x350 x795
1355 x350 x795
1385 x375 x920
net weightlb 47.4 47.4 48.5 59.5 59.5 68.3 88.2 92.6 92.6 110.2
kg 21.5 21.5 22 27 27 31 40 42 42 50
gross weightlb 57.3 57.3 58.4 70.6 70.6 79.4 106.9 110.2 110.2 131.2
kg 26 26 26.5 32 32 36 48.5 50 50 59.5
quantity per 20’/40’/40HQ168/ 352/ 396
168/ 352/ 396
168/ 352/ 396
130/ 280/ 310
130/ 280/ 310
130/ 280/ 310
69/ 145/ 160
69/ 145/ 160
69/ 145/ 160
60/ 125/ 140
Line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
Drainage pipe inch 1 1 1 1 1 1 1 1 1 1
19
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
fan coillow-static
FeATUReS:• Capacity range: 6,000 ~ 19,000 btu/h (1.8kW ~ 5.6kW)• Compact design, saving space• Slim body: 7.5 in (190mm) of height • Noise is down to 26dB(A), extremely silent
technical specifications
Model CMRV H6D3- 1-410
CMRV 76D3- 1-410
CMRV H9D3- 1-410
CMRV H12D3 -1-410
CMRV H15D3 -1-410
CMRV H19D3 -1-410
capacityCOOLIng BTU/H 6,142 7,506 9,554 12,283 15,354 19,107
HEATIng BTU/H 7,506 8,871 10,918 15,354 17,060 21,496
power supply V-Ph-Hz 220-240-1-60
rated power w 40 40 40 40 56 56
air flowCFM 301 301 345 345 533 533
perfor-mance
m3/h 512 512 586 586 906 906
static pressure
in WC 0.02 0.02 0.02 0.02 0.02 0.02
pa 5 5 5 5 5 5
noise level dB(A) 21 21 30 30 31 31
refrigerant Type R410A
net dim. WxHxDin 33.5x7.5x16 33.5x7.5x16 33.5x7..5x16 33.5x7.5x16 41x7.5x17 41x7.5x17
mm 850x190x405 850x190x405 850x190x405 850x190x405 1030x190x430 1030x190x430
packing dim. WxHxD
in 36x11x18 36x11x18 36x11x18 36x11x18 43x11x19 43x11x19
mm 903x277x445 903x277x445 903x277x445 903x277x445 1084x277x472 1084x277x472
net weightlb 25.3 25.3 25.3 25.3 31 31
kg 11.5 11.5 11.5 11.5 14 14
gross weightlb 29.8 29.8 29.8 29.8 35.3 35.3
kg 13.5 13.5 13.5 13.5 16 16
quantity per 20’/40’/40HQ 210/474/562 210/474/562 210/474/562 210/474/562 169/378/452 169/378/452
Line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’
Drainage pipe inch 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
20
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
technical specifications
floor-ceiling
FeATUReS:• Capacity range: 12,000 ~ 48,000 bt/h (3.6kW ~ 14kW)• Flexible installation: vertical or horizontal• Air outlet delivery adjustment: Horizontal and Vertical• Built-in with EXV
ModelCMRV H12U- 1-410
CMRV H15U- 1-410
CMRV H19U- 1-410
CMRV H24U- 1-410
CMRV H27U- 1-410
CMRV H30U- 1-410
CMRV H38U- 1-410
CMRV H48U- 1-410
capacityCOOLIng BTU/H 12,283 15,354 19,107 24,225 27,296 30,708 38,214 47,768
HEATIng BTU/H 13,648 17,060 21,496 27,296 30,708 34,120 42,650 52,886
power supply V-Ph-hz 220-240-1-60
rated power w 120 120 122 125 130 130 182 182
performance air flow
CFM 383 471 471 471 706 706 1165 1165
m3/h 650 800 800 800 1200 1200 1980 1980
noise level dB(A) 36 38 38 38 40 40 42 42
refrigerant type R410A
net dimension WxHxD
in39 x26 x8
39 x26 x8
39 x26 x8
39 x26 x8
50 x26 x8
50 x26 x8
66 x27 x10
66 x27 x10
mm990x 660 x206
990x 660 x206
990x 660 x206
990x 660 x206
1280 x660 x206
1280 x660 x206
1670 x680 x244
1670 x680 x244
packing dimension WxHxD
in43 x29 x12
43 x29 x12
43 x29 x12
43 x29 x12
54 x29 x12
54 x29 x12
54 x29 x12
54 x29 x12
mm1089 x744 x296
1089 x744 x296
1089 x744 x296
1089 x744 x296
1379 x744 x296
1379 x744 x296
1379 x744 x296
1379 x744 x296
net weightlb 60 60 66 66 82 82 119 119
kg 27 27 30 30 37 37 54 54
cross weightlb 70 70 76 76 93 93 134 134
kg 31.8 31.8 34.4 34.4 42 42 61 61
quantity per 20’/40’/40’HQ127/ 224/ 295
127/ 224/ 295
127/ 224/ 295
127/ 224/ 295
96/ 175/ 226
96/ 175/ 226
63/ 132/ 151
63/ 132/ 151
line set
liquid inch 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
drainage pipe inch 1 1 1 1 1 1 1 1
21
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
FeATUReS:• Capacity range: 7,000 ~ 19,000 btu/h (2.2kW ~ 5.6kW)• 2 kinds of panel are optional• Built-in with EXV is standard• New EXV Adopted, FUJIKOKI Brand• 2000 pulse, More precise control of refrigerant flow• No modulation noise of the EXV operation• New panel, fashion design• Can be used in bedroom or hotel etc.• Longer input and output pipe• Easy installation• Front panel may be subject to change
technical specifications
wall-mounted exv
operationlow noise
Model CMRVH-7WX-1-410
CMRVH-9WX-1-410
CMRVH-12WX-1-410
CMRVH-15WX-1-410
CMRVH-19WX-1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354 19,107
HEATIng BTU/H 8,189 10,918 13,648 17,060 21,496
power supply V-Ph-hz 220-240-1-60
rated power w 30 30 30 45 45
performance air flow
CFM 341 341 341 530 530
m3/h 580 580 580 900 900
noise level dB(A) 29 29 29 34 34
refrigerant Type R410A
net dimension WxHxDin 36x11x8 36x11x8 36x11x8 42x12x8 42x12x8
mm 915x290x210 915x290x210 915x290x210 1070x315x210 1070x315x210
packing dimension WxHxD
in 40x15x12 40x15x12 40x15x12 46x16x12 46x16x12
mm 1020x385x300 1020x385x300 1020x385x300 1180x410x300 1180x410x300
net weightlb 26.5 26.5 26.5 33 35
kg 12 12 12 15 16
cross weightlb 35 35 35 42 42
kg 16 16 16 19 19
quantity per 20’/40’/40’HQ 264/543/611 264/543/611 264/543/611 185/402/472 185/402/472
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’
drainage pipe inch 3/4’’ 3/4’’ 3/4’’ 3/4’’ 3/4’’
22
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS:• Capacity range: 7,000 ~ 19,000 (2.2kW ~ 5.6kW)• No Built-in EXV. Included but not installed• Only two sizes for all capacity models: 7,000 ~ 12,000 btu/h (2.2kw though 3.6kw): 36x11x9 in (915x290x230mm) 12,000 ~ 19,000 btu/h (4.5kw through 5.6kw): 42x12x9 in (1072x315x230mm)
wall-mounted standard
Model CMRV H7W-1-410
CMRV H9W-1-410
CMRV H12W-1-410
CMRV H15W-1-410
CMRV H19W-1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354 19,107
HEATIng BTU/H 8,189 10,918 13,648 17,060 21,496
power supply V-Ph-hz 220-240-1-60
rated power w 30 30 30 45 45
performance air flow
CFM 341 341 341 530 530
m3/h 580 580 580 900 900
noise level dB(A) 29 29 29 34 34
refrigerant type R410A
net dimension WxHxDin 36x11x9 36x11x9 36x11x9 42x12x9 42x12x9
mm 915x290x230 915x290x230 915x290x230 1072x315x230 1072x315x230
packing dimension WxHxDin 40x50x12 40x50x12 40x50x12 46x16x12 46x16x12
mm 1020x390x315 1020x390x315 1020x390x315 1180x415x315 1180x415x315
net weightlb 29 29 29 33.3 33.3
kg 13 13 13 15.1 15.1
cross weight kg36.4 36.4 36.4 41.5 41.5
16.5 16.5 16.5 18.8 18.8
quantity per 20’/40’/40’HQ 199/446/542 199/446/542 199/446/542 162/363/440 162/363/440
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’
drainage pipe inch 5/8’’ 5/8’’ 5/8’’ 5/8’’ 5/8’’
technical specifications
23
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
technical specifications
floor standing type AFeATUReS:• Capacity range: 7,000 ~ 27,000 btu/h (2.2kW ~ 8.0kW)• EXV is integrated in the body• Appealing outlook for exposed application• Air inlet from bottom or side is optional• Pipe connection on both sides is optional
reliabilitysystem Model
CMRV H7FA- 1-410
CMRV H9FA- 1-410
CMRV H12FA- 1-410
CMRV H15FA- 1-410
CMRV H19FA- 1-410
CMRV H24FA- 1-410
CMRV H27FA- 1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354 19,107 24,225 27,296
HEATIng BTU/H 8,189 10,918 13,648 17,060 21,496 27,296 30,708
power supply V-Ph-hz 220-240-1-60
rated power w 46 46 49 49 88 130 130
performance air flow
CFM 312 335 367 388 677 812 883
m3/h 530 569 624 660 1150 1380 1500
noise level dB(A) 33 33 35 35 37 38 38
refrigerant Type R410A
net dimension WxHxD
in 39 x25x9
39 x25x9
47 x25x9
47 x25x9
59 x25x9
59 x25x9
59 x25x9
mm1000 x625 x220
1000 x625 x220
1200 x625 x220
1200 x625 x220
1500 x625 x220
1500 x625 x220
1500 x625 x220
packing dimension WxHxD
in 43 x28x12
43 x28x12
51 x28x12
51 28x12
63 x28x12
63 x28x12
63 x28x12
mm1089 x722 x312
1089 x722 x312
1289 x722 x312
1289 x722 x312
1589 x722 x312
1589 x722 x312
1589 x722 x312
net weightlb 66 66 82 82 97 97 97
kg 30 30 37 37 44 44 44
cross weightlb 77 77 95 95 110 110 110
kg 35 35 43 43 50 50 50
quantity per 20’/40’/40’HQ126/ 251/ 294
126/ 251/ 294
103/ 212/ 249
103/ 212/ 249
84/ 172/ 200
84/ 172/ 200
84/ 172/ 200
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’
drainage pipe inch 1 1 1 1 1 1 1
24
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS:• Capacity range: 7,000 ~ 27,000 btu/h (2.2kW ~ 8.0kW)• EXV is integrated in the body• Appealing outlook for exposed application• Air inlet from bottom or side is optional• Pipe connection on both sides is optional
technical specifications
floor standing type B
designstylish
ModelCMRV H7FB- 1-410
CMRV H9FB- 1-410
CMRV H12FB- 1-410
CMRV H15FB- 1-410
CMRV H19FB- 1-410
CMRV H24FB- 1-410
CMRV H27FB- 1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354 19,107 24,225 27,296
HEATIng BTU/H 8,189 10,918 13,648 17,060 21,496 27,296 30,708
power supply V-Ph-hz 220-240-1-60
rated power w 46 46 49 49 88 130 130
performance air flow
CFM 312 335 367 388 677 812 883
m3/h 530 569 624 660 1150 1380 1500
noise level dB(A) 33 33 35 35 37 38 38
refrigerant Type R410A
net dimension WxHxD
in 39x25x9 39x25x9 47x25x9 47x25x9 59x25x9 59x25x9 59x25x9
mm1000 x625 x220
1000 x625 x220
1200 x625 x220
1200 x625 x220
1500 x625 x220
1500 x625 x220
1500 x625 x220
packing dimension WxHxD
in 46x28x12 46x28x12 54x28x12 54x28x12 66x28x12 66x28x12 66x28x12
mm1179 x722 x312
1179 x722 x312
1379 x722 x312
1379 x722 x312
1679 x722 x312
1679 x722 x312
1679 x722 x312
net weightlb 66 66 82 82 97 97 97
kg 30 30 37 37 44 44 44
cross weightlb 84 84 101 101 117 117 117
kg 38 38 46 46 53 53 53
quantity per 20’/40’/40’HQ116/ 220/ 268
116/ 220/ 268
97/ 195/ 224
97/ 195/ 224
80/ 162/ 187
80/ 162/ 187
80/ 162/ 187
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’
drainage pipe inch 1 1 1 1 1 1 1
25
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
FeATUReS:• Capacity range: 7,000 ~ 27,000 btu/h (2.2kW ~ 8.0kW)• EXV is integrated in the body• Intended for concealed application• Pipe connection on both sides is optional
floor standing type C
technical specifications
ModelCMRVH-
7FC- 1-410
CMRVH-9FC- 1-410
CMRVH-12FC- 1-410
CMRVH-15FC- 1-410
CMRVH-19FC- 1-410
CMRVH-24FC- 1-410
CMRVH-27FC- 1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354 19,107 24,225 27,296
HEATIng BTU/H 8,189 10,918 13,648 17,060 21,496 27,296 30,708
power supply V-Ph-hz 220-240-1-60
rated power w 46 46 49 49 88 130 130
performance air flow
CFM 312 335 367 388 677 812 883
m3/h 530 569 624 660 1150 1380 1500
noise level dB(A) 33 33 35 35 37 38 38
refrigerant Type R410A
net dimension WxHxD
in 33x21x8 33x21x8 41x21x8 41x21x8 53x21x8 53x21x8 53x21x8
mm840 x544 x212
840 x544 x212
1036 x544 x212
1036 x544 x212
1336 x544 x212
11336 x544 x212
1336 x544 x212
packing dimension WxHxD
in 37x25x12 37x25x12 45x25x12 45x25x12 57x25x12 57x25x12 57x25x12
mm939 x639 x305
939 x639 x305
1139 x639 x305
1139 x639 x305
1439 x639 x305
1439 x639 x305
1439 x639 x305
net weightlb 57 57 65 65 79 79 79
kg 26 26 29.5 29.5 36 36 36
cross weightlb 65 65 75 75 88 88 88
kg 29.5 29.5 34 34 40 40 40
quantity per 20’/40’/40’HQ119/ 236/ 273
119/ 236/ 273
93/ 190/ 215
93/ 190/ 215
72/ 151/ 182
72/ 151/ 182
72/ 151/ 182
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’ 3/8’’ 3/8’’ 3/8’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 5/8’’ 5/8’’ 5/8’’
drainage pipe inch 1 1 1 1 1 1 1
26
VRF
PLU
S •
Ind
OO
R U
nIT
Sw
ww
.com
fort
star
usa.
com
FeATUReS:• Capacity range: 7,000 ~ 15,000 btu/h (2.2kW ~ 4.5kW)• DC fan motor adoption, noise is down to 28dB(A)• 210mm thickness, saving space • Up/Down/Left/Right 4 direction air inlet • Air outlet direction is optional: Up and down air outlet Only up air outlet• Build-in with electrostatic active-carbon filter
console type
technical specifications
energyefficient
Model CMRVH-7CO-1-410
CMRVH-9CO-1-410
CMRVH-12CO-1-410
CMRVH-15CO-1-410
capacityCOOLIng BTU/H 7,506 9,554 12,283 15,354
HEATIng BTU/H 8,871 10,918 13,648 17,060
power supply V-Ph-hz 220-240-1-60
rated power w 20 25 25 45
performance air flow
CFM 324 324 436 436
m3/h 550 550 740 740
noise level dB(A) 28 29 30 32
refrigerant Type R410A
net dimension WxHxDin 28x8x24 28x8x24 28x8x24 28x8x24
mm 700x210x600 700x210x600 700x210x600 700x210x600
packing dimension WxHxDin 32x12x28 32x12x28 32x12x28 32x12x28
mm 810x305x710 810x305x710 810x305x710 810x305x710
net weightlb 29 29 33 33
kg 13 13 15 15
cross weightlb 40 40 44 44
kg 18 18 20 20
quantity per 20’/40’/40’HQ 161/329/376 161/329/376 161/329/376 161/329/376
line set
liquid inch 1/4’’ 1/4’’ 1/4’’ 1/4’’
gas inch 1/2’’ 1/2’’ 1/2’’ 1/2’’
drainage pipe inch 5/8’’ 5/8’’ 5/8’’ 5/8’’
27
VRF PLU
S • Ind
OO
R U
nITS
1-866-524-9898
efficient
outdoor air processing unit
technical specifications
Model CMRVH48OU-1-410 CMRVH85OU-1-410 CMRVH95OU-1-410
capacityCOOLIng BTU/H 47,768 85,300 95,536
HEATIng BTU/H 54,592 88,712 105,772
power supply V-Ph-hz 220-240-1-60
performance
air flowCFM 736 1530 1766
m3/h 1250 2600 3000
static pressure
in. WC 0.79 0.88 0.88
pa 196 220 220
noise level dB(A) 45 48 48
refrigerant Type R410A
net dimension WxHxDin 47x16x24 56x20x36 56x20x36
mm 1200x400x600 1425x500x920 1425x500x920
packing dimension WxHxD
in 56x18x30 59x22x37 59x22x37
mm 1430x450x768 1495x560x950 1495x560x950
net weightlb 29 29 33
kg 13 13 15
cross weightlb 40 40 44
kg 18 18 20
quantity per 20’/40’/40’HQ 161/329/376 161/329/376 161/329/376
line set
liquid inch 3/8’’ 3/8’’(double) 3/8’’(double)
gas inch 5/8’’ 5/8’’(double) 5/8’’(double)
drainage pipe inch 1 1-1/8’’ 1-1/8’’
FeATUReS:• 3 Different Models: 48,000 btu/h, 85,000 btu/h and 96,000 btu/h• Compact design for diverse ductwork • Suitable for heavy-commercial applications• High-static pressure• Quite blower motor operation• Reliable operation and easy maintenance
28
VRF
PLU
S •
CO
nTR
OLL
eRS
ww
w.c
omfo
rtst
arus
a.co
m
ReMOTe COnTROLLeRModel: CS-RC01
Allows individual control of indoor units wirelessly.
WALL THeRMOSTATModel: CS-WT01
Allows individual control of indoor units.
CenTRALIZed COnTROLLeRModels: CS-CC32-01 and CSCC64-01
Allows centralized control of entire set of outdoor/indoor units for the entire VRF system. Constrained to a maximum of 32 and 64 outdoor/indoor units, respectively.
neTWORK AdAPTeRSModels: CS-nWLW-01 and CS-nWBn-01
Compatibility with Building Management Systems (BMS) through LonWorks and BACNET protocols is an essential benefit of ComfortStar VRF Plus.
BACnET
controllers
Network ControllerCS‐NWBN‐01 CS‐CC64‐01
Max. 64
Max. 64
Max. 64
CS‐CC32‐01
BUILDING MANAGEMENT
Max. 32MANAGEMENT
SYSTEM
Security System
Fire Alarm System
Max. 32
LonWorks
29
VRF PLU
S • AC
CeSSO
RIeS
1-866-524-9898
BRAnCHInG PIPeSComfortStar VRF Plus branch piping is specifically designed to meet performance requirements of the outdoor units. No equivalent piping should be used and the design guidelines in the service manual have to be thoroughly followed, while making branch pipe selection.
accessories
FQZHN-01C
Liquid side joint
FQZHN-02C
Gas side joint
Liquid side joint
FQZHN-03C
Gas side joint
Liquid side joint
FQZHN-04C
Gas side joint
Liquid side joint
Gas side joint
ID:12.7
(ID:15.9)
OD:19.1
ID:19.1
OD:19.1
ID:19.1
ID:15.9ID:12.7
(ID:15.9)
OD:19.1
OD:12.7
ID:9.5ID:9.5
ID:6.4
OD:9.5
ID:6.4
OD:9.5
ID:9.5
OD:12.7
ID:6.4
ID:9.5
OD:12.7
OD:12.7
ID:12.7
ID:9.5
ID:12.7
ID:6.4
ID:9.5
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
OD:22.2
ID:22.2
ID:25.4ID:15.9
(ID:19.1)
OD:22.2
ID:12.7
ID:15.9
OD:15.9
ID:19.1
(ID:12.7)
OD:15.9
ID:9.5
ID:15.9
(ID:12.7)
OD:15.9
ID:9.5
ID:6.4
ID:28.6
ID:31.8
OD:28.6
ID:28.6
ID:19.1
ID:22.2
OD:28.6
ID:19.1
ID:22.2
OD:28.6
ID:15.9
ID:12.7
(ID:15.9)
OD:19.1
ID:19.1
OD:19.1
ID:19.1
ID:22.2
ID:12.7
(ID:15.9)
OD:19.1
ID:9.5
ID:19.1
ID:22.2
ID:28.6
OD:34.9
ID:34.9
OD:34.9
ID:38.1ID:22.2
ID:28.6
OD:34.9
ID:34.9
Gas side joint Gas side joint
Liquid side joint Liquid side joint
Gas side joint
FQZHN-05C FQZHN-06C
FQZHW-02N1C
ID:34.9
ID:41.3
ID:34.9
ID:41.3
ID:41.3
ID:44.5
ID:44.5
OD:41.3
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
OD:22.2
ID:22.2
ID:25.4ID:15.9
(ID:19.1)
OD:22.2
ID:12.7
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
(ID:19.1)
OD:22.2
ID:22.2
ID:25.4ID:25.4
OD:22.2
ID:54
ID:34.9
ID:41.3
ID:63.5
ID:54
OD:54
OD:54
ID:41.3
ID:63.5
0D:31.8ID:31.8
ID:25.4
Q1
0D:34.9
ID:38.1
ID:34.9
Q3
ID:34.9
ID:31.8
ID:31.8
Q4
ID:25.4
0D:31.8
Q2
Liquid side joint
Gas side joint
FQZHW-03N1C
ID:15.9
0D:19.1ID:19.1
ID:15.9
ID:22.2
ID:19.1ID:15.9
0D:15.9ID:12.7
ID:12.7
0D:15.9
Y1
Y6 Y3Y2
ID:31.8
0D:34.9
ID:31.8ID:38.1
ID:34.90D:31.8
ID:25.4
0D:31.8
ID:31.8
ID:25.4
Q1
Q2Q7
ID:38.1
ID:41.3
ID:31.8
0D:31.8ID:31.8
ID:25.4
Q1
Q5
CSZHn-01C
CSZHn-03C CSZHn-04C
CSZHn-02C
Liquid side joint
Liquid side jointGas side joint
FQZHW-04N1C
ID:19.1ID:22.2
ID:15.9
0D:15.9ID:15.9
ID:12.7
Y1
Y7
0D:22.2
ID:19.1
Y4
ID:15.9
ID:15.9
ID:19.1
ID:15.9
0D:15.9ID:12.7
ID:12.7
0D:15.9
Y1
Y6Y2
ID:31.8
0D:34.9
ID:31.8ID:38.1
ID:34.90D:31.8
ID:25.4
0D:31.8
ID:31.8
ID:25.4
Q1
Q2Q7
ID:38.1
ID:41.3
ID:31.8
0D:31.8ID:31.8
ID:25.4
Q1
Q5
ID:41.3
ID:44.5
ID:31.8
0D:31.8ID:31.8
ID:25.4
Q1
Q6
ID:19.1ID:22.2
ID:15.9
0D:15.9ID:15.9
ID:12.7
Y1
Y7
0D:25.4ID:25.4ID:22.2
ID:22.2ID:15.9
0D:15.9ID:15.9
ID:12.7
Y1
Y8 Y5
ID:15.9
ID:19.1
ID:15.9
ID:15.9
0D:15.9ID:12.7
ID:12.7
0D:15.9
Y1
Y6Y2
CSZHW-04n1C
FQZHN-01C
Liquid side joint
FQZHN-02C
Gas side joint
Liquid side joint
FQZHN-03C
Gas side joint
Liquid side joint
FQZHN-04C
Gas side joint
Liquid side joint
Gas side joint
ID:12.7
(ID:15.9)
OD:19.1
ID:19.1
OD:19.1
ID:19.1
ID:15.9ID:12.7
(ID:15.9)
OD:19.1
OD:12.7
ID:9.5ID:9.5
ID:6.4
OD:9.5
ID:6.4
OD:9.5
ID:9.5
OD:12.7
ID:6.4
ID:9.5
OD:12.7
OD:12.7
ID:12.7
ID:9.5
ID:12.7
ID:6.4
ID:9.5
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
OD:22.2
ID:22.2
ID:25.4ID:15.9
(ID:19.1)
OD:22.2
ID:12.7
ID:15.9
OD:15.9
ID:19.1
(ID:12.7)
OD:15.9
ID:9.5
ID:15.9
(ID:12.7)
OD:15.9
ID:9.5
ID:6.4
ID:28.6
ID:31.8
OD:28.6
ID:28.6
ID:19.1
ID:22.2
OD:28.6
ID:19.1
ID:22.2
OD:28.6
ID:15.9
ID:12.7
(ID:15.9)
OD:19.1
ID:19.1
OD:19.1
ID:19.1
ID:22.2
ID:12.7
(ID:15.9)
OD:19.1
ID:9.5
ID:19.1
ID:22.2
ID:28.6
OD:34.9
ID:34.9
OD:34.9
ID:38.1ID:22.2
ID:28.6
OD:34.9
ID:34.9
Gas side joint Gas side joint
Liquid side joint Liquid side joint
Gas side joint
FQZHN-05C FQZHN-06C
FQZHW-02N1C
ID:34.9
ID:41.3
ID:34.9
ID:41.3
ID:41.3
ID:44.5
ID:44.5
OD:41.3
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
OD:22.2
ID:22.2
ID:25.4ID:15.9
(ID:19.1)
OD:22.2
ID:12.7
ID:15.9
(ID:19.1)
OD:22.2
ID:22.2
(ID:19.1)
OD:22.2
ID:22.2
ID:25.4ID:25.4
OD:22.2
ID:54
ID:34.9
ID:41.3
ID:63.5
ID:54
OD:54
OD:54
ID:41.3
ID:63.5
0D:31.8ID:31.8
ID:25.4
Q1
0D:34.9
ID:38.1
ID:34.9
Q3
ID:34.9
ID:31.8
ID:31.8
Q4
ID:25.4
0D:31.8
Q2
Liquid side joint
Gas side joint
FQZHW-03N1C
ID:15.9
0D:19.1ID:19.1
ID:15.9
ID:22.2
ID:19.1ID:15.9
0D:15.9ID:12.7
ID:12.7
0D:15.9
Y1
Y6 Y3Y2
ID:31.8
0D:34.9
ID:31.8ID:38.1
ID:34.90D:31.8
ID:25.4
0D:31.8
ID:31.8
ID:25.4
Q1
Q2Q7
ID:38.1
ID:41.3
ID:31.8
0D:31.8ID:31.8
ID:25.4
Q1
Q5
CSZHn-05C
CSZHW-02n1C
CSZHW-03n1C
CSZHn-06C
30
VRF
PLU
S •
TR
AIn
InG
ww
w.c
omfo
rtst
arus
a.co
m
COMPReHenSIVe TRAInInG SeSSIOnS are provided in our headquarters or can be arranged by request in your location. These trainings are intended for diversified audiences: contractors, architects, engineers.
Trainings target familiarization with ComfortStar VRF Plus product line, features & benefits, advanced-level explanation of our technology, thorough coverage of installation procedures (mechanical and electrical), system start-up procedure, equipment selection and service & troubleshooting.
Ask your local representative for availability of training sessions.
training
VRF–VARIABLE REFRIGERANT FLOW
Training Contents:• Installation & Commissioning• Service & Troubleshooting
Keys for Part-Load Efficiency:• Inverter-Driven compressor• On-demand Cooling/Heating• DC Fan Motor• Modular Condensing Units• Heat Recovery• CFD Optimized Heat Exchanger
31
VRF Plu
s 1-866-524-9898VRF
APPLIED COMMERCIAL AIR CONDITIONING
TM
VRFAPPLIED COMMERCIAL AIR CONDITIONING
TM
engineering solutionsVRF PLUS IS A dIVISIOn OF COMFORTSTAR dedicated to providing applied engineering solutions for HVAC commercial applications. Such projects call for superior product quality, service and support. Our sales engineering team is committed to approaching each project with the highest standard of professionalism and providing our customers with engineering support for project sizing, robust equipment selection through specialized VRF Plus software, installation and start-up commissioning.
PART #VRFplus-2011-110111
All rights reserved printed in the United States of America. This publication is protected by copyright, and permission must be obtained by eAir, LLC prior to any reproduction or transmission in any norm
or by any means. Trademarks: ComfortStar logo is a registered brand of eAir, LLC
COMFORTSTAR® 12201 N.W. 107th Ave.
Medley, Fla 33178toll free: 1-866-524-9898
fax: 305-500-9896e-mail: [email protected]: www.comfortstarusa.com
VRFAPPLIED COMMERCIAL AIR CONDITIONING
TM