von bartels gmbh country · zeus cpc 26 zeus cpc 27 collector type evacuated tubular collector...

2
Country Web E-mail Tel +49 0 K 10 K 30 K 50 K 70 K 52 K mm mm mm W W W W W W 5,31 2.000 2.655 135 2.363 2.271 2.063 1.827 1.560 1.801 5,54 2.000 2.768 135 2.465 2.369 2.153 1.906 1.628 1.879 5,76 2.000 2.881 135 2.563 2.463 2.238 1.981 1.692 1.954 5,99 2.000 2.995 135 2.666 2.561 2.328 2.061 1.760 2.032 6,22 2.000 3.108 135 2.768 2.660 2.417 2.140 1.827 2.110 6,44 2.000 3.222 135 2.866 2.754 2.503 2.215 1.892 2.185 6,67 2.000 3.335 135 2.968 2.852 2.592 2.294 1.960 2.263 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 445 428 389 344 294 339 η0,hem a1 a2 - W/(m²K) W/(m²K²) 0,445 1,670 0,007 0,180 0,000 0,000 0,910 Yes Angle 10° 20° 30° 40° 50° 60° 70° 80° 90° K θT,coll 1,01 0,00 K θL,coll 0,88 0,00 Heat transfer medium for testing Flow rate for testing (per gross area, A G ) 0,020 Maximum temperature difference for thermal performance calculations 52 190 6,7 - 600 The effective thermal capacity value was obtained from the Test Report Nr. 04-17/KT dated 30.01.2017 issued by Institut für Solarenergieforschung GmbH . Central Offices: Kalavriton 4, 145 64 kifisia, Athens, Tel: +301 6233493-4 , Fax: +301 6233495, http://www.dqshellas.gr, e-mail: [email protected] 4181 DQ5 8/2/2017 Comments of testing laboratory Datasheet version: 5.01, 2016-03-01 Test report(s) 4180 DE5 Dated 8/2/2017 4181 DE5 8/2/2017 Maximum operating pressure p max,op kPa Testing laboratory NCSR Demokritos / Solar & other Energy Systems Laboratory www.solar.demokritos.gr Effective thermal capacity, incl. fluid (per gross area, A G ) C/m 2 kJ/(Km 2 ) Maximum operating temperature ϑ max_op °C Water dm/dt kg/(sm²) m a ) max K Standard stagnation temperature (G = 1000 W/m²; ϑ a = 30 °C) ϑ stg °C Bi-directional incidence angle modifiers Incidence angle modifier Transversal Longitudinal Performance parameters (related to AG) Units Test results Incidence angle modifier test method Steady state - outdoor Power output per m² gross area Performance parameters test method Steady state - outdoor Zeus cpc 28 Zeus cpc 29 Zeus cpc 30 Gb = 850 W/m²; Gd = 150 W/m² ϑm - ϑa Zeus cpc 24 Zeus cpc 25 Zeus cpc 26 Zeus cpc 27 Collector Type Evacuated tubular collector Collector name Gross area (A G ) Gross length Gross width Gross height Power output per collector Street, Number 10, Ravensberger Str. [email protected] Postcode, City 32361 Pr. Oldendorf 5742 70462-0 Licence holder VON BARTELS GmbH GERMANY Brand (optional) Page 1/2 Annex to Solar Keymark Certificate - Summary of EN ISO 9806:2013 Test Results Licence Number OEM 10000/1 Date issued 2016-11-30 Issued by DQS Hellas

Upload: trankiet

Post on 10-Nov-2018

222 views

Category:

Documents


0 download

TRANSCRIPT

Country

Web

E-mail

Tel +49

0 K 10 K 30 K 50 K 70 K 52 K

m² mm mm mm W W W W W W

5,31 2.000 2.655 135 2.363 2.271 2.063 1.827 1.560 1.801

5,54 2.000 2.768 135 2.465 2.369 2.153 1.906 1.628 1.879

5,76 2.000 2.881 135 2.563 2.463 2.238 1.981 1.692 1.954

5,99 2.000 2.995 135 2.666 2.561 2.328 2.061 1.760 2.032

6,22 2.000 3.108 135 2.768 2.660 2.417 2.140 1.827 2.110

6,44 2.000 3.222 135 2.866 2.754 2.503 2.215 1.892 2.185

6,67 2.000 3.335 135 2.968 2.852 2.592 2.294 1.960 2.263

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

0 0 0 0 0 0

445 428 389 344 294 339

η0,hem a1 a2

- W/(m²K) W/(m²K²) 0,445 1,670 0,007 0,180 0,000 0,000 0,910

Yes

Angle 10° 20° 30° 40° 50° 60° 70° 80° 90°

KθT,coll 1,01 0,00

KθL,coll 0,88 0,00

Heat transfer medium for testing

Flow rate for testing (per gross area, AG) 0,020

Maximum temperature difference for thermal performance calculations 52

190

6,7

-

600

The effective thermal capacity value was obtained from the Test Report Nr. 04-17/KT

dated 30.01.2017 issued by Institut für Solarenergieforschung GmbH .

Central Offices: Kalavriton 4, 145 64 kifisia, Athens, Tel: +301 6233493-4 , Fax: +301 6233495, http://www.dqshellas.gr, e-mail:

[email protected]

4181 DQ5 8/2/2017

Comments of testing laboratory Datasheet version: 5.01, 2016-03-01

Test report(s) 4180 DE5 Dated 8/2/20174181 DE5 8/2/2017

Maximum operating pressure pmax,op kPa

Testing laboratory NCSR Demokritos / Solar & other Energy Systems Laboratory www.solar.demokritos.gr

Effective thermal capacity, incl. fluid (per gross area, AG) C/m2 kJ/(Km2)Maximum operating temperature ϑmax_op °C

Water

dm/dt kg/(sm²)(ϑm-ϑa)max K

Standard stagnation temperature (G = 1000 W/m²; ϑa = 30 °C) ϑstg °C

Bi-directional incidence angle modifiers

Incidence angle modifier

Transversal

Longitudinal

Performance parameters (related to AG)

Units

Test results

Incidence angle modifier test method Steady state - outdoor

Power output per m² gross area

Performance parameters test method Steady state - outdoor

Zeus cpc 28

Zeus cpc 29

Zeus cpc 30

Gb = 850 W/m²; Gd = 150 W/m²

ϑm - ϑa

Zeus cpc 24

Zeus cpc 25

Zeus cpc 26

Zeus cpc 27

Collector Type Evacuated tubular collector

Collector name

Gro

ss

are

a (A

G)

Gro

ss

len

gth

Gro

ss

wid

th

Gro

ss

he

igh

t

Power output per collector

Street, Number 10, Ravensberger Str. [email protected], City 32361 Pr. Oldendorf 5742 70462-0

Licence holder VON BARTELS GmbH GERMANY

Brand (optional)

Page 1/2

Annex to Solar Keymark Certificate - Summary of EN ISO

9806:2013 Test Results

Licence Number OEM 10000/1

Date issued 2016-11-30

Issued by DQS Hellas

ϑm 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C 25°C 50°C 75°C

3.607 2.715 1.905 2.841 2.087 1.436 2.071 1.454 966 2.232 1.554 1.0173.763 2.833 1.988 2.964 2.178 1.498 2.160 1.517 1.008 2.329 1.621 1.0613.912 2.945 2.067 3.082 2.264 1.558 2.246 1.577 1.048 2.422 1.685 1.1034.069 3.063 2.149 3.205 2.355 1.620 2.336 1.640 1.090 2.518 1.753 1.1484.225 3.180 2.232 3.328 2.445 1.682 2.425 1.703 1.132 2.615 1.820 1.1924.374 3.293 2.311 3.446 2.532 1.742 2.511 1.763 1.172 2.707 1.884 1.2344.531 3.411 2.393 3.569 2.622 1.804 2.601 1.826 1.214 2.804 1.952 1.278

679 511 359 535 393 270 390 274 182 420 293 192

Central Offices: Kalavriton 4, 145 64 kifisia, Athens, Tel: +301 6233493-4 , Fax: +301 6233495, http://www.dqshellas.gr, e-mail:

[email protected]

Incidence angle modifier IAM (50°) 0,00 --

Remark: The data given in this section are related to collector

reference area (A sol ) which is aperture area for values according to

EN 12975-2 or gross area for ISO 9806. Consistent data sets for

either aperture or gross area can be used in calculations like in the

regulation 811 and 812 and simulation programs.

First-order coefficient (a1) 1,67 W/(m²K)

Second-order coefficient (a2) 0,007 W/(m²K²)

Data required for CDR (EU) No 812/2013 - Reference Area Asol

Zero-loss efficiency (η0 ) 0,445 --

Zeus cpc 30 6,67

37 %

Zeus cpc 25 5,54 Remark: Collector efficiency (η col ) is defined in CDR (EU) No

811/2013 as collector efficiency of the solar collector at a

temperature difference between the solar collector and the

surrounding air of 40 K and a global solar irradiance of 1000 W/m²,

expressed in % and rounded to the nearest integer. Deviating from

the regulation η col is based on reference area (A sol ) which is

aperture area for values according to EN 12975-2 or gross area for

ISO 9806:2013.

Zeus cpc 26 5,76

Hail resistance using steel ball (maximum drop height) 0,4 m

Energy Labelling Information

Reference Area, Asol (m2) Data required for CDR (EU) No 811/2013 - Reference Area Asol

Zeus cpc 27 5,99

Zeus cpc 28 6,22

Zeus cpc 29 6,44

Zeus cpc 24 5,31 Collector efficiency (ηcol)

Maximum tested positive load 2400 Pa

Maximum tested negative load - Pa

The collector is deemed to be suitable for roof integration No

The collector was tested successfully according to EN ISO 9806:2013 under the following conditions:

Climate class (A, B or C) A --

The collector is operated at constant temperature ϑm (mean of in- and outlet temperatures). The calculation of the annual collector

performance is performed with the official Solar Keymark spreadsheet tool Scenocalc Ver. 5.01 (March 2016). A detailed description

of the calculations is available at www.solarkeymark.org/scenocalc

Additional Information Collector heat transfer medium Water-Glycole

Hybrid Thermal and Photo Voltaic collector No

Mean annual ambient air temperature 18,5°C 3,2°C 7,5°C 9,0°C

Collector orientation or tracking mode South, 25° South, 30° South, 45° South, 35°

Fixed (slope = latitude - 15°; rounded to nearest 5°)

Annual irradiation on collector plane 1765 kWh/m² 1714 kWh/m² 1166 kWh/m² 1244 kWh/m²

Annual output per m² gross area

Fixed or tracking collector

Zeus cpc 30

Zeus cpc 24Zeus cpc 25Zeus cpc 26Zeus cpc 27Zeus cpc 28Zeus cpc 29

Annual collector output in kWh/collector at mean fluid temperature ϑm, based on ISO 9806:2013 test results

Collector name

Standard Locations Athens Davos Stockholm Würzburg

Page 2/2

Annex to Solar Keymark Certificate Licence Number OEM 10000/1

Supplementary Information Issued 2016-11-30