vm4, vem4, - abb · 2021. 2. 17. · ve4 af09(z)...38(z) + v(e)m4 assembly - anbau - montage -...

2
ABB France 3, rue Jean Perrin 69680 Chassieu / France www.abb.com/lowvoltage VEM4 NC 01NC 01 KM2 A1 A2 A1 A2 KM1 A1 A2 + - A1 A2 DC AF09 ... 16(Z) AF26 ... 38(Z) VEM4 + VM4 KM1 KM2 VM4 VM4 + VM4 + + - A1 A2 A1 A2 AF09(Z) ... AF16(Z) AF26(Z) ... AF38(Z) AF09(Z)..S ... AF16(Z)..S AF26(Z)..S ... AF26(Z)..S VM4 + AFS09(Z) ... AFS16(Z) AFS26(Z) ... AFS38(Z) AF09(Z)...38(Z) + - A1 A2 DC 1SBC101028M6801- 05/18 VM4, VEM4, Mechanical interlock VM4, mechanical/electrical interlocks VEM4, Mechanische Verriegelung VM4, mechanische/elektrische Verriegelungen VEM4, Verrouillage mécanique VM4, verrouillages mécanique/électrique VEM4, Mekanisk förregling VM4, mekanisk/elektrisk förregling VEM4, Interblocco meccanico VM4, interblocco meccanico-elettrico VEM4, Enclavamiento mecanico VM4, enclavamientos mecanico y electrico VEM4, VEM4, VM4, Operating instructions Betriebsanleitung Notice d'instruction Instruktion Istruzioni tecniche Instrucciones de empleo , VEM4, A1 A2 A1 A2 *AF/AFS...-30-22 : electrical test only 2 x 1..2,5 2 x 0,75..2,5 mm 2 mm 2 Ø 5,5 pozidriv N°2 1 x 0,75..2,5 2 x 0,75..1,5 mm 2 L L=10mm A2 L < 8mm L 6 1 x 1..2,5 1 x 0,75..2,5 1 x 0,75..2,5 L=10mm M 3,5 1,2 N.m VEM4 TEST 2 x 5 c 5 a TEST 1 x 5 a 4 c b 1 2 3 VM4 Assembly - Anbau - Montage - Montering - Montaggio - Montaje - - CLIC ! b 1 5 ... ... 6 9 VM4 VEM4 VEM4 2 6 7 CLIC ! 8 A2 A2 A2 A1 pozidriv N°2 - 1,2Nm 9 A2 A2 A1 VE4 AF09(Z)...38(Z) + V(E)M4 Assembly - Anbau - Montage - Montaje - Montering - Montaggio - - 2 35 mm EN/IEC 60715 35 mm EN/IEC 60715 AF09(Z)..S ... 26(Z)..S + VM4 AF... * AF... * 2 AFS09(Z) ... AFS38(Z) + VM4

Upload: others

Post on 24-Mar-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VM4, VEM4, - ABB · 2021. 2. 17. · VE4 AF09(Z)...38(Z) + V(E)M4 Assembly - Anbau - Montage - Montaje - Montering - Montaggio - - 2 EN/IEC 60715 35 mm EN/IEC 60715 AF09(Z)..S

ABB France3, rue Jean Perrin69680 Chassieu / Francewww.abb.com/lowvoltage

VEM4

NC

01NC

01

KM2A1

A2

A1

A2KM1

A1

A2

+

-A1

A2 DC

AF09 ... 16(Z)AF26 ... 38(Z)

VEM4 +

VM4

KM1 KM2VM4

VM4 + VM4 +

+

-A1

A2

A1

A2

AF09(Z) ... AF16(Z)AF26(Z) ... AF38(Z)

AF09(Z)..S ... AF16(Z)..SAF26(Z)..S ... AF26(Z)..S

VM4 + AFS09(Z) ... AFS16(Z)AFS26(Z) ... AFS38(Z)

AF09(Z)...38(Z)

+

-A1

A2 DC

1SBC101028M6801- 05/18

VM4, VEM4,

Mechanical interlock VM4, mechanical/electrical interlocks VEM4, Mechanische Verriegelung VM4, mechanische/elektrische Verriegelungen VEM4, Verrouillage mécanique VM4, verrouillages mécanique/électrique VEM4, Mekanisk förregling VM4, mekanisk/elektrisk förregling VEM4, Interblocco meccanico VM4, interblocco meccanico-elettrico VEM4, Enclavamiento mecanico VM4, enclavamientos mecanico y electrico VEM4,

VEM4, VM4,

Operating instructionsBetriebsanleitungNotice d'instructionInstruktionIstruzioni tecnicheInstrucciones de empleo

,

VEM4,

A1

A2

A1

A2

*AF/AFS...-30-22 : electrical test only

2 x1..2,5

2 x0,75..2,5

mm2 mm2

Ø 5,5

pozi

driv

N°2

1 x 0,75..2,52 x 0,75..1,5

mm2L

L=10mm

A2

L < 8mm

L

6

1 x1..2,5

1 x0,75..2,5

1 x0,75..2,5

L=10mm

M 3,51,2 N.m

VEM4

TEST 2 x 5

c

5

a

TEST 1 x 5

a4

cb

12

3

VM4

Assembly - Anbau - Montage - Montering - Montaggio - Montaje - -

CLIC !

b

1 5 ...

...6 9

VM4VEM4

VEM4

2

6

7

CLIC !

8A2

A2

A2

A1

pozidriv N°2 - 1,2Nm9

A2A2A1

VE4

AF09(Z)...38(Z) + V(E)M4

Assembly - Anbau - Montage - Montaje - Montering - Montaggio - -

2

35 m

m

EN/IE

C 60

715

35 mm EN/IEC 60715

AF09(Z)..S ... 26(Z)..S + VM4

AF... * AF... *

2

AFS09(Z) ... AFS38(Z) + VM4

Page 2: VM4, VEM4, - ABB · 2021. 2. 17. · VE4 AF09(Z)...38(Z) + V(E)M4 Assembly - Anbau - Montage - Montaje - Montering - Montaggio - - 2 EN/IEC 60715 35 mm EN/IEC 60715 AF09(Z)..S

AF09(Z) ... 38(Z) + VM4AF09(Z) ... 38(Z)-..-30 + VM4

AF09(Z)...16(Z)-30 + VEM4AF09(Z)...16(Z)-40 + VEM4AF26(Z)...38(Z)-30 + VEM4AF26(Z)...38(Z)-40 + VEM4

A mm inch

B mm inch

AF09(Z) ... 16(Z) AF26(Z) ... 38(Z)-30 111,5 4.39" 80 3.15"

102,5 4.04" 71 2.80"

AF09(Z) ... 38(Z) + VM4, AFS09(Z) ... 38(Z) + VM4

A (AF...) B

35 m

m

EN/IE

C 60

715

10 0.39"

5.5 0.22"

90 3.54" 90 3.54"

6 0.24"

80 3

.15"

2 0.08" 2 0.08" 2 0.08" 2 0.08"

90 3.54"

91.5

3.

60"

AB

5.5 0.22"

35 m

m

EN/IE

C 60

715

10 0.39"

5.5 0.22"

43 1

.69"

5.5 0.22"

AF09(Z) ... 38(Z) + VM4AF09(Z) ... 38(Z) + VEM4AFS09(Z) ... 38(Z) + VM4AF09(Z)-..S ... 26(Z)-..S + VM4

60

2.36

"

ø 4.2 0.17"

80 3.15"

70

2.76

"

5 0

.20"

5 0.20"

2 x M4 8-32 UNC

Amm inch

B mm inch

AF09 ... 16(Z)-..S

AF26(Z)-..S 82,5 3.25" 10 0.39"

80 3.15" 11,5 0.45"

77 3.03"71 2.80"

AF09(Z) ... 16(Z)

AF26(Z) ... 38(Z)-30 86 3.39"80 3.15"

AF26(Z) ... 38(Z)-40 101 3.98" 95 3.74"

Amm inch

B mm inch

AF09(Z)...38(Z) + VEM4

AF26(Z) ... 38(Z)-40 95 3.74"126,5 4.98"

90 3.54" 2 0.08" 2 0.08"

AB

AF09...26(Z)-..S + VM4

6 0.24"

Pos.1

Pos. 4

Pos. 2

Pos. 3

AF09(Z)...16(Z)-30-10AF09(Z)...16(Z)-40-00AF26(Z)...38(Z)-30-00

VEM4 + max 5 aux. contacts / 3NC

AF09(Z)...16(Z)-30-01AF26(Z)...38(Z)-40-00

VEM4 + max 5 aux. contacts / 2NC Pos.1 ± 30 °

+30° -30°

Pos. 5

AF09(Z)...16(Z)-30-10AF09(Z)...16(Z)-40-00AF26(Z)...38(Z)-30-00

VEM4 + max 5 aux. contacts / 2NC

AF09(Z)...16(Z)-30-01AF26(Z)...38(Z)-40-00

VEM4 + max 5 aux. contacts / 1NC

AF09(Z) ... 38(Z)-..-30 + VM4,AFS09(Z) ... 38(Z)-..-30 + VM4

AFS09(Z) ... 38(Z) + VM4AFS09(Z) ... 38(Z)-..-30 + VM4

2 0.08’’2 0.08’’

80 3

.15’

A1 (AFS...)

A1mm inch

_

_

_

_

_

110,5 4.35"

119,5 4.70"

A1mm inch

_

_130,5 5.14"

139,5 5.49"

AFS09(Z) ... 16(Z)

AFS26(Z) ... 38(Z)-30

A1 (AFS..-..-30)

_

_

Warning ! Hazardous voltage! The operation, installation and servicing of this appliance must be carried out by a quali�ed electrician applying the relevant rules of the art, installation standards and safety regulations. Before operating the contactors, check that control voltage complies with the data of the coil. Connection to other control voltage can destroy the coil. Do not touch live parts. Danger !Warnung ! Gefährliche Spannung! Die Inbetriebnahme und die Installation des vorhandenen Gerätes sowie jegliche Wartungsarbeiten müssen durch einen Fachelektriker, der die anerkannten technischen Regeln, die Montagenormen und die Sicherheitsvorschriften beachtet, durchgeführt werden. Vor Inbetriebnahme der Schütze prüfen ob Steuerspannung am Verwendungsort mit den aufgedruckten Spulendaten übereinstimmt. Der Anschluss einer anderen Steuerspannung kann zur Zerstörung der Spule führen. Spannung führende Teile nicht berühren. Lebensgefahr ! Avertissement ! Tension électrique dangereuse! La mise en œuvre, l'installation de cet appareil et toute intervention doivent être e�ectuées par un électricien professionnel appliquant les règles de l'art, les normes d'installation et les réglements de sécurité. Avant la mise en marche des contacteurs, véri�er que la tension du circuit de contrôle correspond bien aux indications de la bobine. Le raccordement d'une tension di�érente peut mener à une destruction de la bobine. Ne pas toucher les pièces sous tension. Danger de mort !Varning ! Farlig spänning! Igångsättning och installation av aparaten samt alla ingrepp bör utföras av en kompetent elektriker enligt gällande installationsnormer och säkerhetsregler. Kontrollera före installation av kontaktorn att aktuell manöverspänning överensstämmer med spolens märkdata. Felaktig manöverspänning kan skada spolen. Beröring av spänningsförande delar är förenat med livsfara.Avvertenza ! Tensione pericolosa! La messa in opera, l'installazione di questo apparecchio ed ogni tipo di intervento devono essere e�ettuati da un elettricista professionista il quale applichi le regole del mestiere, le norme di installazione ed i regolamenti di sicurezza. Prima della messa in servizio del contattore, veri�care che la tensione del circuito di comando corrisponda esattamente a quella indicata sulla bobina. L'alimentazione con una tensione diversa, puo provocare la distruzione della bobina. Non toccare le parti attive. Pericolo di vita !¡ Advertencia ! Tensión peligrosa! La puesta en aplicación, la instalación de este aparato y cualquier intervención deben realizarse por un electricista profesional que aplique las reglas del o�cio, las normas de instalaciones y la reglamentación de seguridad. Antes de la puesta en servicio del contactor, comprobar si coinciden la tensión de mando con los datos impresos en la bobina. La conexión de otra tensión de mando puede producir la destruccion de la bobina. Las partes bajo tensión no deben tocarse. Peligro de muerte !

OCTOPOЖHO! Опасное напряжение!

35m

m E

N/E

C 60

715

5.5 0.22"

B

A (AF..-..-30)

5.5 0.22"

10 0.39"

Amm inch

B mm inch

AF09Z...16Z-...-30AFS09Z...16Z-...-30

AF26Z...38Z-...-30 3-pole AFS26Z...38Z-...-30 3-pole 100 3.94"

AF09(Z)...26(Z)-..S + VM4

A B

35 m

m

EN/IE

C 60

715

10 0.39"

5.5 0.22"

5.5 0.22"

77 3.03" 71 2.80"AF09(Z) ...16(Z)-..S

AF26(Z)-30-..S 86 3.39" 80 3.15"

Amm inch

B mm inch

106 4.17"

91 3.58"97 3.82"