vividgro v2 grow fixture installation guide / …...licensed electrician will provide proper plug...

3
Read All Product Labels and Directions Prior to Beginning Installation. (Illustrations provided are for reference only, and may appear different in person) CAUTION: RISK OF ELECTRIC SHOCK. See important safety and installation instructions and operations. Ensure the AC service is OFF before and during installation or any maintenance. INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN DISCONNECTED. Ground leads must always be connected before other leads. CAUTION: Protect all personnel against electrical shock WARNING! Lighting Science warranty VOID if fixture is not installed by a licensed electrician or someone with similar qualifications. REQUIREMENTS Installation should be performed only by a qualified electrician in accordance with the National Electrical Code and must be installed in accordance with all applicable local and national electrical codes. For code interpretation, please contact your local authority. This product must be installed in full accordance with applicable electrical and building codes by a person familiar with the construction and operation of this fixture and all involved hazards. This device complies with Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in typical installations. This product may cause interference with cordless and cellular phones, radios and other electronic devices. This product should not be installed near maritime safety communications equipment or other critical navigation and communication equipment operating between 0.45-30MHz. Do not remove external optical assembly from luminaire frame- IP and ETL ratings of luminaire will be compromised. Fixture weight is 64 lbs. Ensure the support structure you will use to hang this fixture meets or exceeds the combined weight load requirements for all fixtures you plan to install. 877-999-5742 | www.lsgc.com 1830 Penn Street | Melbourne, FL 32901 VIVIDGRO V2 Grow Fixture_InstallationGuide_REVD_11-12-2015 ©2015 Lighting Science Group Corporation. All rights reserved. Specifications are typical values and may change without notification. VIVIDGRO V2 GROW FIXTURE Installation Guide / User Manual SPECIFICATIONS PAR Output 1081 μmol / s Power Consumption (Watts) 588W PAR Efficacy (μmol / J) 1.838 μmol/J delivered LEDs 312 High Power LEDs Input Voltage 100-277 VAC, 50/60 Hz Weight 29.0kg / 64lbs Mounting Height 18"- 24" Above Canopy Housing Rugged, Die-Cast Aluminim Housing and Optical-Grade Weather Resistant Polycarbonate Cover Power Factor >0.95 CCT 3R1W (2500k) Operating Temperature -40 ° C ~ 80 ° C Storage Temperature -30 ° C ~ 40 ° C Environmental Rating IP65 Beam Angle 65 ° Warranty 5 Year Limited Dimensions 1077(L) x 603(W) x 110(H)mm 42.4"(L) x23.74"(W) x 4.33"(H) Specifications supplied are nominal. Please refer to the DOE’s Lighting Facts Tolerance Guidelines. 1 Values are nominal, advances from further innovation, specifications are subject to change. IP65 North American Certifications Environment SAFETY WARNINGS CONTENTS: (1) VIVIDGRO™ V2 Luminaire (4) 24" Straight Cable Hangers (1) Installation Manual TOOLS REQUIRED: Standard Installation Tools

Upload: others

Post on 12-Apr-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VIVIDGRO V2 GROW FIXTURE Installation Guide / …...Licensed electrician will provide proper plug and outlet meeting local electrical codes for fi xture during installation. Alternatively,

Read All Product Labels and Directions Prior to Beginning Installation. (Illustrations provided are for reference only, and may appear different in person)

• CAUTION: RISK OF ELECTRIC SHOCK. See important safety and installation instructions and operations. Ensure the AC service is OFF before and during installation or any maintenance. INSTALLATION SHOULD ONLY BE PERFORMED AFTER POWER TO THE FIXTURE HAS BEEN DISCONNECTED. Ground leads must always be connected before other leads.

• CAUTION: Protect all personnel against electrical shock

• WARNING! Lighting Science warranty VOID if fi xture is not installed by a licensed electrician or someone with similar qualifi cations.

REQUIREMENTS• Installation should be performed only by a qualifi ed electrician

in accordance with the National Electrical Code and must be installed in accordance with all applicable local and national electrical codes. For code interpretation, please contact your local authority. This product must be installed in full accordance with applicable electrical and building codes by a person familiar with the construction and operation of this fi xture and all involved hazards.

• This device complies with Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in typical installations. This product may cause interference with cordless and cellular phones, radios and other electronic devices. This product should not be installed near maritime safety communications equipment or other critical navigation and communication equipment operating between 0.45-30MHz.

• Do not remove external optical assembly from luminaire frame-IP and ETL ratings of luminaire will be compromised.

• Fixture weight is 64 lbs. Ensure the support structure you will use to hang this fi xture meets or exceeds the combined weight load requirements for all fi xtures you plan to install.

877-999-5742 | www.lsgc.com 1830 Penn Street | Melbourne, FL 32901

VIVIDGRO V2 Grow Fixture_InstallationGuide_REVD_11-12-2015 ©2015 Lighting Science Group Corporation. All rights reserved. Specifi cations are typical values and may change without notifi cation.

VIVIDGRO™ V2 GROW FIXTUREInstallation Guide / User Manual

SPECIFICATIONSPAR Output 1081 µmol / s

Power Consumption (Watts) 588W

PAR Effi cacy (µmol / J) 1.838 µmol/J delivered

LEDs 312 High Power LEDs

Input Voltage 100-277 VAC, 50/60 Hz

Weight 29.0kg / 64lbs

Mounting Height 18"- 24" Above Canopy

Housing Rugged, Die-Cast Aluminim Housing and Optical-Grade Weather Resistant Polycarbonate Cover

Power Factor >0.95

CCT 3R1W (2500k)

Operating Temperature -40 ° C ~ 80 ° C

Storage Temperature -30 ° C ~ 40 ° C

Environmental Rating IP65

Beam Angle 65 °

Warranty 5 Year Limited

Dimensions 1077(L) x 603(W) x 110(H)mm 42.4"(L) x23.74"(W) x 4.33"(H)

Specifi cations supplied are nominal. Please refer to the DOE’s Lighting Facts Tolerance Guidelines.1 Values are nominal, advances from further innovation, specifi cations are subject to change.

IP65North American Certifi cations Environment

SAFETY WARNINGS

CONTENTS:• (1) VIVIDGRO™ V2 Luminaire

• (4) 24" Straight Cable Hangers

• (1) Installation Manual

TOOLS REQUIRED:Standard Installation Tools

Page 2: VIVIDGRO V2 GROW FIXTURE Installation Guide / …...Licensed electrician will provide proper plug and outlet meeting local electrical codes for fi xture during installation. Alternatively,

INSTALLATION INSTRUCTIONS:

1) Affi x the cable hangers to the luminaire.

2) Connect the Power Cables to the junction box. Follow the calbe instruction label to connect the power cables L/N/G individually. The GROUND WIRE must be connected securely!

AMP CHART120V 5.0 amps

240V 2.5 amps

277V 2.2 amps

DIMENSIONS:

MOUNTING

877-999-5742 | www.lsgc.com 1830 Penn Street | Melbourne, FL 32901

VIVIDGRO V2 Grow Fixture_InstallationGuide_REVD_11-12-2015 ©2015 Lighting Science Group Corporation. All rights reserved. Specifi cations are typical values and may change without notifi cation.

VIVIDGRO™ V2 GROW FIXTUREInstallation Guide / User Manual

SAFETY WARNINGSWIRING AND MOUNTING:

WARNING: Turn off source power at fuse or circuit breaker.

During installation never allow the fi xture to rest on the lens assembly.

Attach fi xture using included (4) Straight CableHanger assembly to overhead facility mounting hardware (not supplied.) Check with local codes for mounting regulations and restrictions.

WARNING: Fixture weighs ~64 lbs. Ensure proper structural support is provided to support total weight of all fi xtures used in installation.

The fi xture is provided with a pigtail termination on the cord. Licensed electrician will provide proper plug and outlet meeting local electrical codes for fi xture during installation. Alternatively, fi xture can be hardwired to J-Box. A licensed electrician should connect minimum 16 AWG input power connections (120 VAC – 277 VAC) using conduit rated stranded copper conductors to input power wiring harness. Connect to black conductor for line, the white conductor for Neutral, and the green conductor for Ground.

Secure the connections with wire nuts approved for the conductor sizes (not supplied with fi xture).

TYPICAL WIRING CONFIGURATIONS

120VAC

240VAC

277VAC

Page 3: VIVIDGRO V2 GROW FIXTURE Installation Guide / …...Licensed electrician will provide proper plug and outlet meeting local electrical codes for fi xture during installation. Alternatively,

877-999-5742 | www.lsgc.com 1830 Penn Street | Melbourne, FL 32901

VIVIDGRO V2 Grow Fixture_InstallationGuide_REVD_11-12-2015

©2015 Lighting Science Group Corporation. All rights reserved. Specifi cations are typical values and may change without notifi cation.

VIVIDGRO ™ V2 GROW FIXTUREInstallation Guide / User Manual

WARRANTYLighting Science Group Corporation warrants our products to be free from defects in materials and workmanship under normal use and service for a period of 5 years from date of purchase. This warranty extends to the original buyer or end-user customer of a Lighting Science authorized reseller, and does not apply to fuses, batteries or to any product which, in Lighting Science’s opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling.

Lighting Sciences warranty obligation is limited, at Lighting Science’s opinion, to refund of the purchase price, or free-of-charge repair and/or replacement of defective product or component which is returned to an authorized Lighting Science repair facility within the warranty period.

To Make a Warranty Claim: Retain the failed Product(s) and invoice(s), and notify your Lighting Science sales representative or agent in writing within thirty (30) days of the Product’s failure. To establish a claim under this Limited Warranty, proof of installation by a licensed electrician will be required. Lighting Science may require the return, at your cost, of the product claimed to be defective to a facility designated by Lighting Science.

THIS WARRANTY IS PURCHASER’S SOLE AND EXCLUSIVE REMEDY AND IN IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO , ANY IMPLIED WARRANTY OF MERCHANTABILITY OR SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.

Since some countries and states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not a ect the validity orenforceability of any other provision of this warranty.

Polar Intensity

Iso-Irradiance

PHOTOMETRIC DISTRIBUTION

Zonal mmol/sec Summary

0-20 9.95

0-30 21.01

0-40 32.74

0-60 45.20

0-80 47.23

0-90 47.37

10-90 44.85

20-40 22.78

20-50 31.13

40-70 13.98

60-80 2.03

70-80 .52

80-90 .14

Representante Exclusivo

©2016 BHP Energy México.Todos los derechos reservados.

www. bhpenergy.mx

Bosque de Ciruelos No. 190 Int. 204-205Col. Bosques de las Lomas, CDMX 11700

Tel: +52 55 5251 [email protected]

[email protected]