The change in viscosity is measured by monitoringthe amplitude of an oscillating steel ball
in a specially designed cuvette.
Clot detection is based on the increasein viscosity of the plasma being tested.
![Page 3: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/3.jpg)
ACTIVATING COILACTIVATING COIL ACTIVATING COILACTIVATING COIL
Movement of the steel ball is mediated by 2 activating coils,working alternatively to induce and maintain
a natural oscillation.
![Page 4: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/4.jpg)
When the start reagent is added,the detection and the chronometer start
immediately and simultaneously.
![Page 5: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/5.jpg)
As the ball oscillates left and right, the amplitude of the motion is measured.
The chronometer times the clotting of the sample.
![Page 6: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/6.jpg)
As the ball oscillates left and right, the amplitude of the motion is measured.
The chronometer times the clotting of the sample.
![Page 7: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/7.jpg)
Amplitude is monitored during the entire clotting process.The amplitude remains constant while no clot is present.
![Page 8: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/8.jpg)
As the clot develops the viscosity increases,and the amplitude decreases.
![Page 9: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/9.jpg)
Based on different algorithms, the chronometer is stoppedeven if the clot is weak, and even if the ball is not stopped.
![Page 10: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/10.jpg)
Maximum sensitivity for:
• Weak clots
• Fibrinogen testing linearity 1.5 to 9 g/L
• All clotting tests
Insensitivity to:
• Coloured plasmas • Haemolysed plasmas • Lipemic plasmas • Bilirubin • Turbid reagents
Standardisation:
• For each clotting process • For the entire range of
Stago analysers
![Page 11: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/11.jpg)
STart Max STA Compact Max
STA Satellite Max STA R Max
![Page 12: Viscosity-based detection system - LAPROPHARM PLUS · 2019. 7. 29. · Diagnostica Stago S.A.S RCS Nanterre B305 151 409 3 allée Thérésa 92600 Asnières sur Seine France Ph. +33](https://reader035.vdocuments.site/reader035/viewer/2022062610/610ada1c6ee5183bf333a1e3/html5/thumbnails/12.jpg)
Diagnostica Stago S.A.SRCS Nanterre B305 151 4093 allée Thérésa92600 Asnières sur Seine FrancePh. +33 (0)1 46 88 20 20Fax +33 (0)1 47 91 08 [email protected]
This document contains information on products which is targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .