virtuallun migrationtoraidsatadriveunconfiguredspace
DESCRIPTION
VirtualLUN MigrationtoRAIDSATADriveUnconfiguredSpaceVirtualLUN MigrationtoRAIDSATADriveUnconfiguredSpaceVirtualLUN MigrationtoRAIDSATADriveUnconfiguredSpaceTRANSCRIPT
Title
VirtualLUNMigrationtontoRAIDSATAunconfiguredspace_sym001 Virtual LUN Migration to RAID SATA unconfigured space
OverviewVirtual LUN migration is from source devices to equally-sized target devices, or disks with free space equal to the source devices. A migration will not disrupt hosts or internal applications.
A virtual LUN migration may be initiated in the following circumstances: Traditional data management involves moving data to a lower tier as it ages and becomes less critical to the business. Protection might change as the data ages.
Emerging tiered storage configurations include moving data continuously during the lifecycle, either to optimize price/performance or respond to cyclical business changes.
This procedure is based on content from the following EMC manuals: EMC Solutions Enabler Symmetrix Array Controls CLI Product Guide, v7.0This document can be obtained from the EMC Powerlink website at:http://Powerlink.EMC.com
( Done
1. Determine the diskgroup where the migration should be performed.
Use the symdisk command to list all physical drives in the array sorted by diskgroup. In the output shown below, diskgroup 0 contains 300 GB (15,000 RPM) Fibre Channel Drives, while diskgroup 1 contains 1TB (7,200 RPM) SATA drives.
symdisk list -by_diskgroup -sid 54
Symmetrix ID : 000192601254
Disks Selected : 240
Capacity(MB)
Ident Symb Int TID Vendor Type Hypers Total Free Actual
------ ---- --- --- ---------- ---------- ------ -------- -------- --------
Disk Group 0:
DF-7A 07A C 0 SEAGATE T300155 0 0 0 279140
DF-7A 07A C 2 SEAGATE T300155 63 279140 194293 279140
DF-7A 07A C 4 SEAGATE T300155 60 279140 177651 279140
DF-7A 07A C 6 SEAGATE T300155 62 279140 182092 279140
DF-7A 07A C 8 SEAGATE T300155 67 279140 185253 279140
...
DF-10D 10D D 1 SEAGATE T300155 63 279140 194293 279140
DF-10D 10D D 3 SEAGATE T300155 62 279140 182691 279140
DF-10D 10D D 5 SEAGATE T300155 65 279140 179162 279140
DF-10D 10D D 7 SEAGATE T300155 58 279140 142692 279140
DF-10D 10D D 9 SEAGATE T300155 66 279140 179169 279140
DF-10D 10D D B SEAGATE T300155 64 279140 184670 279140
Disk Group 1:
DF-7A 07A C C SATAHGST N01THGK 21 953870 919264 953870
DF-7A 07A C E SATAHGST N01THGK 15 953870 918501 953870
DF-7A 07A D B SATAHGST N01THGK 22 953870 906665 953870
DF-7A 07A D D SATAHGST N01THGK 9 953870 927315 953870
...
DF-9D 09D D C SATAHGST N01THGK 24 953870 912929 953870
DF-9D 09D D E SATAHGST N01THGK 16 953870 914117 953870
DF-10D 10D C C SATAHGST N01THGK 21 953870 919264 953870
DF-10D 10D D D SATAHGST N01THGK 20 953870 915434 953870Use the symdisk command, as show below, to list the proposed target diskgroup (in this case diskgroup 1), to determine if there is sufficient freespace in the diskgroup, and sufficient DAs and physical drives to support RAID5 7+1 devices.
symdisk list -sid 54 -disk_group 1
Symmetrix ID : 000192601254
Disks Selected : 56
Capacity(MB)
Ident Symb Int TID Vendor Type Hypers Total Free Actual
------ ---- --- --- ---------- ---------- ------ -------- -------- --------
DF-7A 07A C C SATAHGST N01THGK 21 953870 919264 953870
DF-7A 07A C E SATAHGST N01THGK 15 953870 918501 953870
DF-7A 07A D B SATAHGST N01THGK 22 953870 906665 953870
DF-7A 07A D D SATAHGST N01THGK 9 953870 927315 953870
DF-8A 08A C B SATAHGST N01THGK 18 953870 908690 953870
DF-8A 08A C D SATAHGST N01THGK 21 953870 864817 953870
DF-8A 08A D C SATAHGST N01THGK 24 953870 912929 953870
DF-8A 08A D E SATAHGST N01THGK 9 953870 931691 953870
DF-9A 09A C C SATAHGST N01THGK 21 953870 919264 953870
DF-9A 09A C E SATAHGST N01THGK 15 953870 918501 953870
DF-9A 09A D D SATAHGST N01THGK 22 953870 906665 953870
DF-10A 10A C B SATAHGST N01THGK 18 953870 908690 953870
DF-10A 10A C D SATAHGST N01THGK 21 953870 864817 953870
DF-10A 10A D C SATAHGST N01THGK 24 953870 912929 953870
DF-10A 10A D E SATAHGST N01THGK 9 953870 931691 953870
DF-7B 07B C B SATAHGST N01THGK 19 953870 908682 953870
DF-7B 07B C D SATAHGST N01THGK 20 953870 864825 953870
DF-7B 07B D C SATAHGST N01THGK 24 953870 912929 953870
DF-7B 07B D E SATAHGST N01THGK 9 953870 935629 953870
DF-8B 08B C C SATAHGST N01THGK 22 953870 914880 953870
DF-8B 08B C E SATAHGST N01THGK 15 953870 918501 953870
DF-8B 08B D B SATAHGST N01THGK 22 953870 906665 953870
DF-8B 08B D D SATAHGST N01THGK 9 953870 927315 953870
DF-9B 09B C B SATAHGST N01THGK 19 953870 908682 953870
DF-9B 09B C D SATAHGST N01THGK 20 953870 864825 953870
DF-9B 09B D C SATAHGST N01THGK 24 953870 912929 953870
DF-9B 09B D E SATAHGST N01THGK 9 953870 935629 953870
DF-10B 10B C C SATAHGST N01THGK 22 953870 914880 953870
DF-10B 10B C E SATAHGST N01THGK 15 953870 918501 953870
DF-10B 10B D D SATAHGST N01THGK 22 953870 906665 953870
DF-7C 07C C C SATAHGST N01THGK 21 953870 919264 953870
DF-7C 07C D B SATAHGST N01THGK 20 953870 915160 953870
DF-7C 07C D D SATAHGST N01THGK 9 953870 927315 953870
DF-8C 08C C B SATAHGST N01THGK 20 953870 904297 953870
DF-8C 08C C D SATAHGST N01THGK 21 953870 864817 953870
DF-8C 08C D C SATAHGST N01THGK 24 953870 912929 953870
DF-8C 08C D E SATAHGST N01THGK 15 953870 918501 953870
DF-9C 09C C C SATAHGST N01THGK 21 953870 919264 953870
DF-9C 09C D D SATAHGST N01THGK 20 953870 915160 953870
DF-10C 10C C B SATAHGST N01THGK 20 953870 904297 953870
DF-10C 10C C D SATAHGST N01THGK 21 953870 864817 953870
DF-10C 10C D C SATAHGST N01THGK 24 953870 912929 953870
DF-10C 10C D E SATAHGST N01THGK 15 953870 918501 953870
DF-7D 07D C B SATAHGST N01THGK 20 953870 904297 953870
DF-7D 07D C D SATAHGST N01THGK 21 953870 864817 953870
DF-7D 07D D C SATAHGST N01THGK 24 953870 912929 953870
DF-7D 07D D E SATAHGST N01THGK 16 953870 914117 953870
DF-8D 08D C C SATAHGST N01THGK 21 953870 919264 953870
DF-8D 08D D B SATAHGST N01THGK 20 953870 915434 953870
DF-8D 08D D D SATAHGST N01THGK 9 953870 927315 953870
DF-9D 09D C B SATAHGST N01THGK 20 953870 904297 953870
DF-9D 09D C D SATAHGST N01THGK 21 953870 864817 953870
DF-9D 09D D C SATAHGST N01THGK 24 953870 912929 953870
DF-9D 09D D E SATAHGST N01THGK 16 953870 914117 953870
DF-10D 10D C C SATAHGST N01THGK 21 953870 919264 953870
DF-10D 10D D D SATAHGST N01THGK 20 953870 915434 953870.
(
2. Identify the proposed target diskgroup
Use The symdisk command shown below to list the proposed target diskgroup (in this case diskgroup 1), to determine if there is sufficient freespace in the diskgroup, and sufficient DAs and physical drives to support RAID5 7+1 devices.
symdisk list -sid 54 -disk_group 1
Symmetrix ID : 000192601254
Disks Selected : 56
Capacity(MB)
Ident Symb Int TID Vendor Type Hypers Total Free Actual
------ ---- --- --- ---------- ---------- ------ -------- -------- --------
DF-7A 07A C C SATAHGST N01THGK 21 953870 919264 953870
DF-7A 07A C E SATAHGST N01THGK 15 953870 918501 953870
DF-7A 07A D B SATAHGST N01THGK 22 953870 906665 953870
DF-7A 07A D D SATAHGST N01THGK 9 953870 927315 953870
DF-8A 08A C B SATAHGST N01THGK 18 953870 908690 953870
DF-8A 08A C D SATAHGST N01THGK 21 953870 864817 953870
DF-8A 08A D C SATAHGST N01THGK 24 953870 912929 953870
DF-8A 08A D E SATAHGST N01THGK 9 953870 931691 953870
DF-9A 09A C C SATAHGST N01THGK 21 953870 919264 953870
DF-9A 09A C E SATAHGST N01THGK 15 953870 918501 953870
DF-9A 09A D D SATAHGST N01THGK 22 953870 906665 953870
DF-10A 10A C B SATAHGST N01THGK 18 953870 908690 953870
DF-10A 10A C D SATAHGST N01THGK 21 953870 864817 953870
DF-10A 10A D C SATAHGST N01THGK 24 953870 912929 953870
DF-10A 10A D E SATAHGST N01THGK 9 953870 931691 953870
DF-7B 07B C B SATAHGST N01THGK 19 953870 908682 953870
DF-7B 07B C D SATAHGST N01THGK 20 953870 864825 953870
DF-7B 07B D C SATAHGST N01THGK 24 953870 912929 953870
DF-7B 07B D E SATAHGST N01THGK 9 953870 935629 953870
DF-8B 08B C C SATAHGST N01THGK 22 953870 914880 953870
DF-8B 08B C E SATAHGST N01THGK 15 953870 918501 953870
DF-8B 08B D B SATAHGST N01THGK 22 953870 906665 953870
DF-8B 08B D D SATAHGST N01THGK 9 953870 927315 953870
DF-9B 09B C B SATAHGST N01THGK 19 953870 908682 953870
DF-9B 09B C D SATAHGST N01THGK 20 953870 864825 953870
DF-9B 09B D C SATAHGST N01THGK 24 953870 912929 953870
DF-9B 09B D E SATAHGST N01THGK 9 953870 935629 953870
DF-10B 10B C C SATAHGST N01THGK 22 953870 914880 953870
DF-10B 10B C E SATAHGST N01THGK 15 953870 918501 953870
DF-10B 10B D D SATAHGST N01THGK 22 953870 906665 953870
DF-7C 07C C C SATAHGST N01THGK 21 953870 919264 953870
DF-7C 07C D B SATAHGST N01THGK 20 953870 915160 953870
DF-7C 07C D D SATAHGST N01THGK 9 953870 927315 953870
DF-8C 08C C B SATAHGST N01THGK 20 953870 904297 953870
DF-8C 08C C D SATAHGST N01THGK 21 953870 864817 953870
DF-8C 08C D C SATAHGST N01THGK 24 953870 912929 953870
DF-8C 08C D E SATAHGST N01THGK 15 953870 918501 953870
DF-9C 09C C C SATAHGST N01THGK 21 953870 919264 953870
DF-9C 09C D D SATAHGST N01THGK 20 953870 915160 953870
DF-10C 10C C B SATAHGST N01THGK 20 953870 904297 953870
DF-10C 10C C D SATAHGST N01THGK 21 953870 864817 953870
DF-10C 10C D C SATAHGST N01THGK 24 953870 912929 953870
DF-10C 10C D E SATAHGST N01THGK 15 953870 918501 953870
DF-7D 07D C B SATAHGST N01THGK 20 953870 904297 953870
DF-7D 07D C D SATAHGST N01THGK 21 953870 864817 953870
DF-7D 07D D C SATAHGST N01THGK 24 953870 912929 953870
DF-7D 07D D E SATAHGST N01THGK 16 953870 914117 953870
DF-8D 08D C C SATAHGST N01THGK 21 953870 919264 953870
DF-8D 08D D B SATAHGST N01THGK 20 953870 915434 953870
DF-8D 08D D D SATAHGST N01THGK 9 953870 927315 953870
DF-9D 09D C B SATAHGST N01THGK 20 953870 904297 953870
DF-9D 09D C D SATAHGST N01THGK 21 953870 864817 953870
DF-9D 09D D C SATAHGST N01THGK 24 953870 912929 953870
DF-9D 09D D E SATAHGST N01THGK 16 953870 914117 953870
DF-10D 10D C C SATAHGST N01THGK 21 953870 919264 953870
DF-10D 10D D D SATAHGST N01THGK 20 953870 915434 953870Prior to migrating the device, the output of the symdev show command of one of the devices as shown below identifies that the device is locally protected by a single RAID1 primary RAID group, configured in diskgroup 0, as well as being remotely protected.
symdev show be8 -sid 54
Device Physical Name : /dev/rdsk/emcpower35c
Device Symmetrix Name : 0BE8
Device Serial ID : 5400BE8000
Symmetrix ID : 000192601254
Device Group Name : app01 Device Logical Name : DEV001
Number of RAID Groups : 1
Attached BCV Device : N/A
Attached VDEV TGT Device : N/A
Vendor ID : EMC
Product ID : SYMMETRIX
Product Revision : 5874
Device WWN : 60000970000192601254533030424538
Device Emulation Type : FBA
Device Defined Label Type: N/A
Device Defined Label : N/A
Device Sub System Id : 0x0150
Cache Partition Name : DEFAULT_PARTITION
Device Block Size : 512
Device Capacity
{
Cylinders : 9206
Tracks : 138090
512-byte Blocks : 17675520
MegaBytes : 8631
KiloBytes : 8837760
}
Device Configuration : RDF1+Mir
Device is WORM Enabled : No
Device is WORM Protected : No
SCSI-3 Persistent Reserve: Disabled
Dynamic Spare Invoked : No
Dynamic RDF Capability : RDF1_OR_RDF2_Capable
STAR Mode : No
STAR Recovery Capability : None
STAR Recovery State : NA
Device Service State : Normal
Device Status : Ready (RW)
Device SA Status : Ready (RW)
Front Director Paths (3):
{
----------------------------------------------------------------------
POWERPATH DIRECTOR PORT LUN
--------- ---------- ---- -------- ---------
PdevName Type Type Num Sts VBUS TID SYMM Host
----------------------------------------------------------------------
/dev/rdsk/emcpower35c PARENT FA 07E:0 RW 000 00 0B3 000
c1t5000097208139918d1s2 CHILD FA 07E:0 RW 000 00 0B3 000
c2t5000097208139959d1s2 CHILD FA 07F:1 RW 000 00 001 000
}
Mirror Set Type : [RAID-1,R2 Remote,N/A,N/A]
Mirror Set DA Status : [RW,RW,N/A,N/A]
Mirror Set Inv. Tracks : [0,0,0,0]
Back End Disk Director Information
{
Hyper Type : RAID-1
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 1
Hyper Type : R2 Remote
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 2
}
RAID Group Information
{
Mirror Number : 1
RAID Type : RAID-1
Device Position : Primary
Protection Level : 2
RAID Group Service State : Normal
Failing Member Mask : N/A
Hyper Devices:
{
Device : 0BE8
{
------------------------------------------------------
Disk DA Hyper Member Disk
DA :IT Vol# Num Cap(MB) Num Status Grp# Cap(MB)
------------------------------------------------------
09A:D1 431 10 8768 1 RW 0 279140
07A:D1 430 9 8768 2 RW 0 279140
}
}
}
Clone Device Information
{
Source (SRC) Device Symmetrix Name : 0BE8
Source (SRC) Device Group Name : app01 Source (SRC) Composite Group Name : N/A
Target (TGT) Device Symmetrix Name : 0BF4
Target (TGT) Device Group Name : app01 Target (TGT) Composite Group Name : N/A
State of Session (SRC ====> TGT) : Copied
Percent Copied : 100%
Time of Last Clone Action : Sat Mar 7 13:13:35 2009
Clone State Flags : (Copy) (Diff)
Number of Prot. Tracks for SRC Device : 0
Number of Indir Tracks for TGT Device : 0
Number of Changed Tracks for SRC Device: 0
Number of Changed Tracks for TGT Device: 0
}
RDF Information
{
Device Symmetrix Name : 0BE8
RDF Type : R1
RDF (RA) Group Number : 12 (0B)
Remote Device Symmetrix Name : 1640
Remote Symmetrix ID : 000192601201
R2 Device Is Larger Than The R1 Device : False
Paired with a Diskless Device : False
Paired with a Concurrent Device : False
Paired with a Cascaded Device : False
RDF Pair Configuration : Normal
RDF STAR Mode : False
RDF Mode : Asynchronous
RDF Adaptive Copy : Disabled
RDF Adaptive Copy Write Pending State : N/A
RDF Adaptive Copy Skew (Tracks) : 65535
RDF Device Domino : Disabled
RDF Link Configuration : Fibre
RDF Link Domino : Disabled
Prevent Automatic RDF Link Recovery : Enabled
Prevent RAs Online Upon Power ON : Enabled
Device RDF Status : Ready (RW)
Device SA Status : Ready (RW)
Device RA Status : Ready (RW)
Device Link Status : Ready (RW)
Time of Last Device Link Status Change : Tue Mar 3 16:23:30 2009
Device Suspend State : N/A
Device Consistency State : Disabled
Device Consistency Exempt State : Disabled
RDF R2 Not Ready If Invalid : Disabled
Device RDF State : Ready (RW)
Remote Device RDF State : Write Disabled (WD)
RDF Pair State ( R1 R2 ) : Consistent
Number of R1 Invalid Tracks : 0
Number of R2 Invalid Tracks : 0
RDFA Information:
{
Session Number : 11
Cycle Number : 9003
Number of Devices in the Session : 6
Session Status : Active
Consistency Exempt Devices : No
Session Consistency State : Disabled
Minimum Cycle Time : 00:00:30
Average Cycle Time : 00:00:30
Duration of Last cycle : 00:00:30
Session Priority : 33
Tracks not Committed to the R2 Side: 0
Time that R2 is behind R1 : 00:00:52
R2 Image Capture Time : Sat Mar 7 13:37:14 2009
R2 Data is Consistent : True
R1 Side Percent Cache In Use : 0
R2 Side Percent Cache In Use : 0
Transmit Idle Time : 00:00:00
R1 Side DSE Used Tracks : 0
R2 Side DSE Used Tracks : 0
}
}
(
symmigrate sid 54 name mig_01 query detailSymmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 130350 SyncInProg 5 01 RAID-5(7+1) mig_01
0BE9 N/A 126219 SyncInProg 8 01 RAID-5(7+1) mig_01
0BEA N/A 138090 SyncInProg 0 01 RAID-5(7+1) mig_01
0BEB N/A 130604 SyncInProg 5 01 RAID-5(7+1) mig_01
0BEC N/A 521677 SyncInProg 5 01 RAID-5(7+1) mig_01
0BF0 N/A 512295 SyncInProg 7 01 RAID-5(7+1) mig_01
Total --------
Tracks 1559235
MB(s) 97452.2
Done(%) 5
(
3. Use the devices in normal replication functions During the migration of the devices it is possible to use them in normal replication functions, such as TimeFinder/Clone.
The following example shows the results of running the symclone recreate command with-precopy, as the migration data transfer process continues. symclone -g app01 recreate precopy -nop
'Recreate' operation execution is in progress for
device group 'app01'. Please wait...
'Recreate' operation successfully initiated for device group
'app01'.Execute a symclone query on the devices as shown below to show that the recreate was successful.
symclone -g app01 query
Device Group (DG) Name: app01DG's Type : RDF1
DG's Symmetrix ID : 000192601254
Source Device Target Device State Copy
-------------------------------- --------------------------- ------------ ----
Protected Modified Modified
Logical Sym Tracks Tracks Logical Sym Tracks CGDP SRC TGT (%)
--------------------------------- ---------------------------- ------------ ----
DEV001 0BE8 0 0 BCV001 0BF4 0 XXXX PreCopy 100
DEV002 0BE9 0 0 BCV002 0BF5 0 XXXX PreCopy 100
DEV003 0BEA 0 0 BCV003 0BF6 0 XXXX PreCopy 100
DEV004 0BEB 0 0 BCV004 0BF7 0 XXXX PreCopy 100
DEV005 0BEC 0 0 BCV005 0BF8 0 XXXX PreCopy 100
DEV006 0BF0 0 0 BCV006 0BFC 0 XXXX PreCopy 100
Total ------- -------- --------
Track(s) 0 0 0
MB(s) 0.0 0.0 0.0
Legend:
(C): X = The background copy setting is active for this pair.
. = The background copy setting is not active for this pair.
(G): X = The Target device is associated with this group.
. = The Target device is not associated with this group.
(D): X = The Clone session is a differential copy session.
. = The Clone session is not a differential copy session.
(P): X = The pre-copy operation has completed one cycle
. = The pre-copy operation has not completed one cycleThe following example shows that the Clone session can also be activated during the Virtual LUN migration:symclone -g app01 activate -v -nop
'Activate' operation execution is in progress for
device group 'app01'. Please wait...
'Activate' operation successfully executed for device group
'app01'.symclone -g app01 query
Device Group (DG) Name: app01DG's Type : RDF1
DG's Symmetrix ID : 000192601254
Source Device Target Device State Copy
-------------------------------- --------------------------- ------------ ----
Protected Modified Modified
Logical Sym Tracks Tracks Logical Sym Tracks CGDP SRC TGT (%)
-------------------------------- --------------------------- ------------ ----
DEV001 0BE8 0 0 BCV001 0BF4 0 XXX. Copied 100
DEV002 0BE9 0 0 BCV002 0BF5 0 XXX. Copied 100
DEV003 0BEA 0 0 BCV003 0BF6 0 XXX. Copied 100
DEV004 0BEB 0 0 BCV004 0BF7 0 XXX. Copied 100
DEV005 0BEC 0 0 BCV005 0BF8 0 XXX. Copied 100
DEV006 0BF0 0 0 BCV006 0BFC 0 XXX. Copied 100
Total -------- -------- --------
Track(s) 0 0 0
MB(s) 0.0 0.0 0.0
Legend:
(C): X = The background copy setting is active for this pair.
. = The background copy setting is not active for this pair.
(G): X = The Target device is associated with this group.
. = The Target device is not associated with this group.
(D): X = The Clone session is a differential copy session.
. = The Clone session is not a differential copy session.
(P): X = The pre-copy operation has completed one cycle
. = The pre-copy operation has not completed one cycle
(
4. Set a query to run automatically at the given intervalUse the symmigrate query command with the i interval options to allow for the query to be run automatically at the given interval (in seconds).
Note: The following example shows that after the second iteration of the query an estimated time to completion is included with the output, along with the current data transfer rate.
symmigrate sid 54 name mig_01 query detail i 30
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 122105 SyncInProg 11 01 RAID-5(7+1) mig_01
0BE9 N/A 111455 SyncInProg 19 01 RAID-5(7+1) mig_01
0BEA N/A 125653 SyncInProg 9 01 RAID-5(7+1) mig_01
0BEB N/A 121538 SyncInProg 11 01 RAID-5(7+1) mig_01
0BEC N/A 487652 SyncInProg 11 01 RAID-5(7+1) mig_01
0BF0 N/A 465437 SyncInProg 15 01 RAID-5(7+1) mig_01
Total --------
Tracks 1433840
MB(s) 89615.0
Done(%) 13
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 114073 SyncInProg 17 01 RAID-5(7+1) mig_01
0BE9 N/A 97066 SyncInProg 29 01 RAID-5(7+1) mig_01
0BEA N/A 113263 SyncInProg 17 01 RAID-5(7+1) mig_01
0BEB N/A 111889 SyncInProg 18 01 RAID-5(7+1) mig_01
0BEC N/A 450766 SyncInProg 18 01 RAID-5(7+1) mig_01
0BF0 N/A 417749 SyncInProg 24 01 RAID-5(7+1) mig_01
Total --------
Tracks 1304806
MB(s) 81550.4
Done(%) 21
Copy rate : 237.2 MB/S
Estimated time to completion : 00:05:43
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 105711 SyncInProg 23 01 RAID-5(7+1) mig_01
0BE9 N/A 81868 SyncInProg 40 01 RAID-5(7+1) mig_01
0BEA N/A 100104 SyncInProg 27 01 RAID-5(7+1) mig_01
0BEB N/A 101759 SyncInProg 26 01 RAID-5(7+1) mig_01
0BEC N/A 415857 SyncInProg 24 01 RAID-5(7+1) mig_01
0BF0 N/A 369116 SyncInProg 33 01 RAID-5(7+1) mig_01
Total --------
Tracks 1174415
MB(s) 73400.9
Done(%) 29
Copy rate : 239.7 MB/S
Estimated time to completion : 00:05:06
Note that while the migration is in the SyncInProg state, the output of a symdev show command shows the device being migrated is i being locally protected by two separate RAID groups the primary RAID1 group which the device started with, and a secondary RAID5 group to which the device is being migrated. The secondary RAID group can be seen to belong to diskgroup 1, while the primary RAID group belongs to diskgroup 0.
# symdev show be8 -sid 54 Device Physical Name : /dev/rdsk/emcpower35c
Device Symmetrix Name : 0BE8
Device Serial ID : 5400BE8000
Symmetrix ID : 000192601254
Device Group Name : app01 Device Logical Name : DEV001
Number of RAID Groups : 2
... Device Configuration : RDF1+Mir
Device Service State : Normal
Device Status : Ready (RW)
Device SA Status : Ready (RW)
Front Director Paths (3):
{
----------------------------------------------------------------------
POWERPATH DIRECTOR PORT LUN
--------- ---------- ---- -------- ---------
PdevName Type Type Num Sts VBUS TID SYMM Host
----------------------------------------------------------------------
/dev/rdsk/emcpower35c PARENT FA 07E:0 RW 000 00 0B3 000
c1t5000097208139918d1s2 CHILD FA 07E:0 RW 000 00 0B3 000
c2t5000097208139959d1s2 CHILD FA 07F:1 RW 000 00 001 000
}
Mirror Set Type : [RAID-1,R2 Remote,RAID-5,N/A]
Mirror Set DA Status : [RW,RW,RW,N/A]
Mirror Set Inv. Tracks : [0,0,102197,0]
Back End Disk Director Information
{
Hyper Type : RAID-1
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 1
Hyper Type : R2 Remote
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 2
Hyper Type : RAID-5
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 3
}
RAID Group Information
{
Mirror Number : 1
RAID Type : RAID-1
Device Position : Primary
Protection Level : 2
RAID Group Service State : Normal
Failing Member Mask : N/A
Hyper Devices:
{
Device : 0BE8
{
------------------------------------------------------
Disk DA Hyper Member Disk
DA :IT Vol# Num Cap(MB) Num Status Grp# Cap(MB)
------------------------------------------------------
09A:D1 431 10 8768 1 RW 0 279140
07A:D1 430 9 8768 2 RW 0 279140
}
}
Mirror Number : 3
RAID Type : RAID-5
Device Position : Secondary
Protection Level : 7+1
RAID Group Service State : Normal
Failing Member Mask : N/A
Hyper Devices:
{
Device : 0BE8
{
------------------------------------------------------
Disk DA Hyper Member Disk
DA :IT Vol# Num Cap(MB) Num Status Grp# Cap(MB)
------------------------------------------------------
09C:CC 406 22 1253 1 RW 1 953870
07A:CC 403 22 1253 2 RW 1 953870
09A:CC 403 22 1253 3 RW 1 953870
08D:CC 399 22 1253 4 RW 1 953870
10D:CC 399 22 1253 5 RW 1 953870
08B:CC 405 23 1253 6 RW 1 953870
10B:CC 405 23 1253 7 RW 1 953870
07C:CC 406 22 1253 8 RW 1 953870
}
}
}
...
(
5. Verify the session status changes to Migrated
At the end of the migration, the symmigrate query command will show the session status change from SyncInProg to Synchronized, to MigrInProg, and finally to Migrated.
Run the the symmigrate query command as shown below to show the session status changes from SyncInProg to Synchronized, to MigrInProg, and finally to Migrated.
symmigrate sid 54 name mig_01 query detail i 30
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 10756 SyncInProg 92 01 RAID-5(7+1) mig_01
0BE9 N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEA N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEB N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEC N/A 19554 SyncInProg 96 01 RAID-5(7+1) mig_01
0BF0 N/A 10702 SyncInProg 98 01 RAID-5(7+1) mig_01
Total --------
Tracks 41012
MB(s) 2563.2
Done(%) 97
Copy rate : 106.5 MB/S
Estimated time to completion : 00:00:24
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BE9 N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEA N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEB N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BEC N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
0BF0 N/A 0 Synchronized 100 01 RAID-5(7+1) mig_01
Total --------
Tracks 0
MB(s) 0.0
Done(%) 100
...
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
0BE9 N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
0BEA N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
0BEB N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
0BEC N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
0BF0 N/A 0 MigrInProg 100 01 RAID-5(7+1) mig_01
Total --------
Tracks 0
MB(s) 0.0
Done(%) 100
Symmetrix ID: 000192601254
Invalid Status Done TGT
Src Tgt Tracks SRC => TGT (%) Dsk Grp TGT Protection Session Name
---- ---- -------- ------------ ---- ------- -------------- ----------------
0BE8 N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
0BE9 N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
0BEA N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
0BEB N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
0BEC N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
0BF0 N/A 0 Migrated 100 01 RAID-5(7+1) mig_01
Total --------
Tracks 0
MB(s) 0.0
Done(%) 100
(
6. Verify all devices in a single session are at the Migration state.
Run the following command to determine if all the devices in a single session have reached the state of Migrated.
symmigrate name mig_01 sid 1254 verify -migrated All session(s) with name 'mig_01' are in 'Migrated' state.
(
7. RAID5 RAID group located on the SATA drives in diskgroup 1.
When the migration session reaches the Migrated status, the symdev show output shows that the devices migrated are now, once again, protected by a single local RAID group. However, the primary RAID group now is the RAID5 RAID group located on the SATA drives in diskgroup 1.
symdev show be8 -sid 54
Device Physical Name : /dev/rdsk/emcpower35c
Device Symmetrix Name : 0BE8
Device Serial ID : 5400BE8000
Symmetrix ID : 000192601254
Device Group Name : app01 Device Logical Name : DEV001
Number of RAID Groups : 1
...
Device Configuration : RDF1+R-5
...
Device Service State : Normal
Device Status : Ready (RW)
Device SA Status : Ready (RW)
Front Director Paths (3):
{
----------------------------------------------------------------------
POWERPATH DIRECTOR PORT LUN
--------- ---------- ---- -------- ---------
PdevName Type Type Num Sts VBUS TID SYMM Host
----------------------------------------------------------------------
/dev/rdsk/emcpower35c PARENT FA 07E:0 RW 000 00 0B3 000
c1t5000097208139918d1s2 CHILD FA 07E:0 RW 000 00 0B3 000
c2t5000097208139959d1s2 CHILD FA 07F:1 RW 000 00 001 000
}
Mirror Set Type : [RAID-5,R2 Remote,N/A,N/A]
Mirror Set DA Status : [RW,RW,N/A,N/A]
Mirror Set Inv. Tracks : [0,0,0,0]
Back End Disk Director Information
{
Hyper Type : RAID-5
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 1
Hyper Type : R2 Remote
Hyper Status : Ready (RW)
Disk [Director, Interface, TID] : [N/A,N/A,N/A]
Disk Director Volume Number : N/A
Hyper Number : N/A
Mirror Number : 2
}
RAID Group Information
{
Mirror Number : 1
RAID Type : RAID-5
Device Position : Primary
Protection Level : 7+1
RAID Group Service State : Normal
Failing Member Mask : N/A
Hyper Devices:
{
Device : 0BE8
{
------------------------------------------------------
Disk DA Hyper Member Disk
DA :IT Vol# Num Cap(MB) Num Status Grp# Cap(MB)
------------------------------------------------------
09C:CC 405 22 1253 1 RW 1 953870
07A:CC 402 22 1253 2 RW 1 953870
09A:CC 402 22 1253 3 RW 1 953870
08D:CC 398 22 1253 4 RW 1 953870
10D:CC 398 22 1253 5 RW 1 953870
08B:CC 405 23 1253 6 RW 1 953870
10B:CC 405 23 1253 7 RW 1 953870
07C:CC 405 22 1253 8 RW 1 953870
}
}
}
...
8. Complete the migrationTo complete the migration, and to remove the migrations session from the Symmetrix, run the symmigrate terminate command as shown below.
symmigrate -sid 54 -name mig_01 terminate -v -nop
'Terminate' operation execution is in progress for
the session named 'mig_01'. Please wait...
STARTING a Migrate 'TERMINATE' operation.
SELECTING the list of Source devices:
Devices: [SELECTED]
Terminate Migration.............................................Started.
Terminate Migration.............................................Done.
The Migrate 'TERMINATE' operation SUCCEEDED.
'Terminate' operation successfully executed for
the session named 'mig_01'.
9. Verify that the session no longer existsExecute the following query to show that the session no longer exists:
symmigrate -sid 54 -name mig_01 query
Symmetrix ID: 000192601254
The device list with session name 'mig_01' does not have any session information.The Virtual LUN migration is now complete.
(Table of Contents
ConfiguringDynamicSRDF_sym002