ViN1C Vipac Engineers and Scientists Limited
279 Normanby Rd, Port Melbourne, VIC 3207, Australia
Private Bag 16, Port Melbourne, VIC 3207, Australia
t. +61 3 9647 9700 I f. +61 3 9646 4370 I e. [email protected]
w. www.vipac.com.au I A.B.N. 33 005 453 627 I A.C.N. 005 453 627
Vipac Engineers & Scientists
Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
30N-19-0099-TRP-6761546-1
24 May 2019
Melbourne • Sydney • Adelaide • Brisbane
ViN1C Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Report Title: Wind Impact Statement Job Title: 27-45 Best Street, Fitzroy
DOCUMENT NO: 30N-19-0099-TRP-6761546-1 PREPARED FOR:
Piedimonte Developments Pty Ltd
27-49A Best Street, North Fitzroy
CONTACT: Darren Woolf
Tel: +61 417 312 266
Fax:
REPORT CODE: TRP
PREPARED BY: Vipac Engineers and Scientists Limited
279 Normanby Rd,
Port Melbourne, VIC 3207,
Australia
Tel: +61 3 9647 9700
Fax: +61 3 9646 4370 PREPARED BY: Author: C__/'-̀ -"-_, Date: 24 May 2019
Eric Yuen
Wind Engineer
REVIEWED BY: Reviewer: 7;c"-S-4.-•"—t, Date: 24 May 2019
Zhuyun Xu
Senior Wind Consultant
AUTHORISED BY:
,... r% Date:24 May 2019
Sophie Lamande
Wind Group Leader
REVISION HISTORY
Revision No. Date Issued Reason/Comments 0 24/05/2019 Initial Issue
1 24/05/2019 Minor Amendments
2
DISTRIBUTION Copy No. Location
Uncontrolled Copy
1 Project
2 Client (PDF Format)
3
KEYWORDS:
NOTE: This is a controlled document within the document control system. If revised, it must be marked SUPERSEDED and returned to the Vipac QA Representative. This document contains commercial, conceptual and engineering information that is proprietary to Vipac Engineers & Scientists Ltd. We specifically state that inclusion of this information does not grant the Client any license to use the information without Vipac's written permission. We further require that the information not be divulged to a third party without our written consent
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 2 of 23
ViPLIC Piedimonte Developments Ply Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
EXECUTIVE SUMMARY
Piedimonte Developments Pty Ltd commissioned Vipac Engineers and Scientists Ltd to prepare a statement of wind effects for the publically accessible areas adjacent to the proposed development at 27-45 Best Street, Fitzroy. This appraisal is based on Vipac's experience as a wind-engineering consultancy.
Drawings of the proposed development were provided by Jackson Clements Burrows Architects in May 2019. The findings of this study can be summarized as follows:
• With the proposed design, the ground level footpaths and pedestrian access ways would be expected to have wind levels within the walking comfort criterion;
• With the proposed design, the wind conditions near the residential lobbies and retail store entrance areas would be expected to be within the recommended standing comfort criterion.
• With the proposed design, the alfresco dining areas on the first floor would be expected to be within the recommended sitting criterion.
• With the proposed design and recommended 1.5m balustrade height, the wind conditions at high level terraces would be expected to be within the recommended walking criterion.
Educating occupants about wind conditions at open terrace/balcony areas during high-wind events and fixing loose, lightweight furniture on the terrace are highly recommended.
The assessments have been made based on experience of similar situations in Melbourne and around the world. As with any opinion, it is possible that an assessment of wind effects based on experience and without detailed experimental validation may not account for all complex flow scenarios in the vicinity.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence
Page 3 of 23
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
TABLE OF CONTENTS
1 INTRODUCTION 5
2 ANALYSIS APPROACH 7
2.1 Site Exposure 8
2.2 Regional Wind Climate 9
2.3 Building Geometry and Orientation 10
2.4 Flow Interactions with Adjacent Developments 11
2.5 Assessment Criteria 12
2.6 Use of Adjacent Pedestrian Occupied Areas & Recommended Comfort Criteria 14
2.6.1 Rooftop areas Recommended Criterion Discussion 14
3 PEDESTRIAN LEVEL WIND EFFECTS 18
3.1 Discussion and Recommendations 18
4 CONCLUSIONS 20
APPENDIX A: ENVIRONMENTAL WIND EFFECTS 21
APPENDIX B: REFERENCES 22
APPENDIX C: DRAWING LIST 23
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 4 of 23
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
1 INTRODUCTION
Piedimonte Developments Pty Ltd commissioned Vipac Engineers and Scientists Ltd to prepare a statement of wind effects for the publically accessible areas adjacent to the proposed development at 27-45 Best Street, Fitzroy. This appraisal is based on Vipac's experience as a wind-engineering consultancy.
The proposed development is bounded by Scotchmer Street to the North, Best Street to the East, Egremont Street to the west, and existing development to the south (see Figure 1). The proposed development comprises of two residential buildings (7 and 5 stories) with a commercial podium (see Figure 2). The surrounding developments, within a 2km radius, are a mixture of suburban dwellings, mid-rise residential developments, park lands and light industrial areas
This report details the opinion of Vipac as an experienced wind engineering consultancy regarding the wind effects in ground level public areas and access-ways adjacent to the development as proposed. No wind tunnel testing has been carried out for this development at this stage. Vipac has carried out wind tunnel studies on a large number of developments of similar shape and having similar exposure to that of the proposed development. These serve as a valid reference for the prediction of wind effects for this development. Empirical data for typical buildings in boundary layer flows has also been used to estimate likely ground level wind conditions adjacent to the proposed development [2] & [3].
Drawings of the proposed development were provided by Jackson Clements Burrows Architects in May 2019 as listed in Appendix C of this report.
- s- ... - . , _ r 1r C;' I. t SCOTCHMER STREET
4-
..u- ir, 4- 0 l'Pif 1011 Niko Proposed . ,... 4" 44 0 '441' 1 te Lu Development N.. A.
,-1 • trIli CO
-%-:''-'-- I 4'.- -- L4
Q Site - *No co .-, co ; • o r-3 • ? --tArr ° .A+11,,,,..1111 zi" ILI
°NM ‘Ii- jillii 0 CO ; 1111
... '' ' Asitffz? .....; - r apj- • -AI ",...aw, ,
1 1," i ; lf- "sk•%,,,-
Figure 1: Aerial view of the proposed development site at 27-45 Best Street, Fitzroy.
24 May 2019
30N-19-0099-TRP-6761546-1 Commercial-In-Confidence
Page 5 of 23
1/8111.V .31.101r V-16MAS:
I=1 - WI
17.3 m
1111 Ills •
sir.
.■■•11 •••■ • 03 *ROJO P1.021
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Figure 2: North Elevations of the proposed development with its approximate height in meters
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence
Page 6 of 23
ViNIC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2 ANALYSIS APPROACH
When considering whether a proposed development is likely to generate adverse wind conditions in adjacent ground level areas, Vipac considers five main points:
• The exposure of the proposed development to wind;
• The regional wind climate;
• The geometry and orientation of the proposed development;
• The interaction of flows with adjacent developments;
• The assessment criteria, determined by the intended use of the public areas affected by wind flows generated or augmented by the proposed development.
The pedestrian wind comfort at specific locations around a site may be assessed by predicting the worst annual 3-second wind gust expected at that location. The location may be deemed generally acceptable for its intended use if the annual 3-second gust is within the threshold values noted in Section 2.5. For cases where Vipac predicts that a location would not meet its appropriate comfort criterion we may recommend the use of wind control devices and/or local building geometry modifications to achieve the desired comfort rating.
24 May 2019
30N-19-0099-TR P-6761546-1
Commercial-In-Confidence Page 7 of 23
47% ' - - • • „3-
.4. 444. 21 k ategory 3 ;-'44 :-/1.
r- 2 0.461 .11PIL:". • v , ft ...04414 ;'.14 1:•;;T:Z
_ 45 Best St' 44.4! -
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.1 SITE EXPOSURE
The proposed development is predominantly surrounded within a 2 km radius by a mix of suburban dwellings, midrise office, parklands and light industrial warehouses. Considering the immediate surroundings and terrain, the site of the proposed development is assumed to be within Terrain Category 3 for all wind directions [1] (see Figure 3).
Figure 3: Assumed terrain categories for wind speed estimation.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 8 of 23
—*—Wrd Velocities, m/s
N
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.2 REGIONAL WIND CLIMATE
The mean and gust wind speeds have been recorded in the Melbourne area for 30 years. These data have been analysed and the directional probability distribution of wind speeds have been determined. The directional distribution of hourly mean wind speed at the gradient height (:-.500m), with a probability of occurring once per year (i.e. 1 year return period) is shown in Figure 4. The wind data at this free stream height are common to all Melbourne city sites and may be used as a reference to assess ground level wind conditions at the site. Figure 4 indicates that the stronger winds can be expected from the northerly, southerly, and westerly directions.
a
Figure 4: Directional Distribution of Annual Return Period Maximum Mean Hourly Wind Velocities (m/s) at gradient height of 500m in Melbourne.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 9 of 23
1 1 11 1 1 I 1 I 11 IIIIIII
TO Till■ TOWNHOUSE TOUNWIOUSE TOWNHOUSE
9GOTCHIAER 911¢E
*4W no Jra T., TOWNHOUSE TCWHHICESE
SIIMM.10
oar
Ti 5,11IEV SLEJONG
ViNIC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.3 BUILDING GEOMETRY AND ORIENTATION
The proposed development comprises of two residential buildings (7 stories and 5 stories) with retail elements in the podium. The towers have a height of approximately 25 m and 17 m. The overall plan-form dimensions are approximately 77 m x 68m with the long axis running from the west to the east (Figure 5).
Figure 5: Ground Level Plan of the proposed development.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 10 of 23
Vi PAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.4 FLOW INTERACTIONS WITH ADJACENT DEVELOPMENTS
The buildings immediately adjacent to the proposed development site, with their approximate building heights in meters are shown in Figure 6. The prevailing winds are from the North and South West. The ground level areas are well sheltered by neighbouring buildings for south-westerly winds; however the ground level is relatively exposed to northerly winds channelling along St Georges Road, which are expected to possess high mean velocities.
Figure 6 : Immediately adjacent buildings and their approximate buildings heights in meters (m) overlaid
24 May 2019
Commercial-In-Confidence 30N-19-0099-TRP-6761546-1 Page 11 of 23
ViN1C Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.5 ASSESSMENT CRITERIA
With some consensus of international opinion, pedestrian wind comfort is rated according to the suitability of certain activities at a site in relation to the expected annual peak 3-second gust velocity at that location for each wind direction. Each of the major areas around the site are characterized by the annual maximum gust wind speeds. Most patrons would consider a site generally unacceptable for its intended use if it were probable that during one annual wind event, a peak 3-second gust occurs which exceeds the established comfort threshold velocity (shown in Table 1). If that threshold is exceeded once per year then it is also likely that during moderate winds, noticeably unpleasant wind conditions would result, and the windiness of the location would be considered as unacceptable.
Table 1: Recommended Wind Comfort and Safety Gust Criteria
Annual Maximum Gust Speed
Result on Perceived Pedestrian Comfort
>23m/s Unsafe (frail pedestrians knocked over)
<20m/s Acceptable for fast walking (waterfront or particular walking areas)
<16m/s Acceptable for walking (steady steps for most pedestrians)
<13m/s Acceptable for standing (window shopping, vehicle drop off, queuing)
<11m/s Acceptable for sitting (outdoor cafés, gardens, park benches)
In a similar manner, a set of hourly mean velocity criteria (see Table 2) with a 0.1% probability of occurrence are also applicable to ground level areas in and adjacent to the proposed development. An area should be within both the relevant mean and gust limits in order to satisfy the particular human comfort and safety criteria in question.
Table 2: Recommended Wind Comfort and Safety Mean Criteria
Mean Speed in
0.1% of Time
Result on Perceived Pedestrian Comfort
>15m/s Unsafe (frail pedestrians knocked over)
<13m/s Acceptable for fast walking (waterfront or particular walking areas)
<10m/s Acceptable for walking (steady steps for most pedestrians)
<7m/s Acceptable for standing (window shopping, vehicle drop off, queuing)
<5m/s Acceptable for sitting (outdoor cafés, gardens, park benches)
24 May 2019
30N-19-0099-TR P-6761546-1
Commercial-In-Confidence Page 12 of 23
Vi?dC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
The Beaufort Scale is an empirical measure that related the wind speed to observed conditions on the land and sea. Table 3 describes the categories of the Beaufort Scale. The comparison between these observed conditions and the comfort criteria described above can be found in Table 4.
Table 3: Beaufort Scale - empirical measure relating wind speed to observed conditions on land
Beaufort Number
Descriptive Term
Wind Speed at 1.75 m height (m/s)
Specification for Estimating Speed
0 Calm 0-0.1
1 Light Air 0.1-1.0 No noticeable wind
2 Light 1.1-2.3 Wind felt on face Breeze
3 Gentle Breeze
2.4-3.8 Hair disturbed, clothing flaps, newspapers difficult to read
4 Moderate 3.9-5.5 Raises dust and loose paper; hair disarranged Breeze
5 Fresh Breeze
5.6-7.5 Force of wind felt on body, danger of stumbling when entering a windy zone
6 Strong Breeze
7.6-9.7 Umbrellas used with difficulty, hair blown straight, difficult to walk steadily, sideways wind force about equal to forwards wind force, wind noise on ears unpleasant
7 Near Gale 9.8-12.0 Inconvenience felt when walking
8 Gale 12.1-14.5 Generally impedes progress, great difficulty with balance in gusts
9 Strong Gale 14.6-17.1 People blown over
Table 4: Comparison between Mean comfort criteria and the observed conditions
Comfort Criteria Beaufort Scale Equivalent
Safety 9 — Strong Gale
Walking 5 — Fresh Breeze
Standing 4-5 — Moderate to Fresh Breeze
Sitting <4 — Moderate Breeze
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence
Page 13 of 23
ViNIC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
2.6 USE OF ADJACENT PEDESTRIAN OCCUPIED AREAS & RECOMMENDED COMFORT CRITERIA
The following table lists the specific areas adjacent to the development and the corresponding recommended criteria.
Table 5: Recommended application of criteria
Area Specific location Recommended Criteria
Public Footpaths and Access ways
Along Scotchmer Street, Egremont Street, Best Street, and the pedestrian pathway ways in the surrounding area (Figure 7).
Walking
Main Building entrances
Residential Lobby at Egremont Street, Scotcher Street and Best Street, as well as the Store Entrances along Best Street (Figure 7).
Standing
Outdoor Dining Areas On the first floor east facing balcony (Figure 8). Sitting
Communal Terraces Communal Terraces on the Roof Level (Figure 9). Walking (see discussion below)
2.6.1 ROOFTOP AREAS RECOMMENDED CRITERION DISCUSSION
Vipac recommends as a minimum that rooftop terrace areas meet the criterion for walking since:
• these areas are not public spaces;
• the use of these areas is optional;
• many similar developments in Melbourne and other Australian capital cities experience wind conditions on balconies and elevated deck areas in the vicinity of the criterion for walking.
However, it should be noted that meeting the walking criterion on elevated recreation areas will be no guarantee that occupants will find wind conditions in these areas acceptable at all times.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 14 of 23
THII TH3
• 10e20 SCOTCHNER STREET
TOWNHCUSE TOWNH
▪
O
▪
USE TOWNHOUSE 6710 4580 03 MP °-" TH2 n44
TOWNHCVSE I TOWNHOUSE
F. 2j'
1
0U 000 ,Tr
U1001 TONE I — I
ViN1C Piedimonte Developments Ply Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Recommended to fulfil Walking Recommended to fulfil Standing
Figure 7: Plan of the Ground level of the proposed development with the recommended comfort criterion overlaid
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 15 of 23
ViNIC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Recommended to fulfil Sitting
Figure 8: Plan of the Level 1 of the proposed development with the recommended comfort criterion overlaid
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 16 of 23
4
aa OaC i
Slaaar
.2:,
aa. 0111
7,11-1
1--- taw aateir ti.M" 2+‘I'3".
Mgr
INGLE S Jo 34
TORE)* EL
INGLE S
3UIL DING
SINGLE STOREY
43 22
ViPAC TIE BOUCOT .1*, NI *Wt...1 81.01+” 51.1Iaa '71 P-.A.Ea".■ a,
gala:WWI% =PIESURS
--
L EIIIII:1 =SEMI
■-•
16160
ft{TA&E =AM. 1000 Aim
COMIAL F0:11 WalCaal
12800 A c.
o"
Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Recommended to fulfil Walking
Figure 9: Plan of the Roof Level of the proposed development with the recommended comfort criterion overlaid
24 May 2019
Commercial-In-Confidence Page 17 of 23 30N-19-0099-TRP-6761546-1
ViniC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
3 PEDESTRIAN LEVEL WIND EFFECTS
3.1 DISCUSSION AND RECOMMENDATIONS
Ground Floor
The proposed development comprises of two residential buildings, 26 m and 17 m high respectively. Due to its orientation and its overall height above the surrounding area, the proposed development is expected to generate adverse wind conditions at the north-eastern and north-western corners on the ground floor. However, the 3.8 m setback of the eastern tower and 6.9 m setback of the western tower from Scotchmer Street, as well as the canopy around the north-eastern corner is expected to ameliorate adverse northerly winds such that these areas meet the recommended walking comfort criterion. As such, the wind conditions at public pedestrian footpaths along Best Street, Scotchmer Street, Egremont Street, the laneway and the surrounding areas are expected to be within the recommended wind comfort criterion of walking.
The retail store entrances along Best Street are under the 1.8 m deep canopies, and setback behind columns. As such, the wind levels at the retail store entrances are expected to be within the recommended standing comfort criterion.
The residential lobby on Best street is setback from the façade line above; the residential lobby along Scotcher Street is beneath a canopy; and the residential lobby on Egremont Street is shielded by the proximity of the surrounding buildings. As such, the residential lobbies are expected to be within the recommended wind comfort criterion of standing
First Level Balcony
The proposed development features an open air alfresco dining area on the east facing balcony on the first floor. This terrace is shielded by the level above, as well a 1.1 m high balustrade. This balcony is expected to be within the recommended sitting comfort criterion.
Roof Level Communal Terrace
The communal terrace is located on the roof level of the eastern residential tower and is approximately 26 m above street level. This communal terrace features a pergola above seating areas as well as a community vegetable garden. Due to its height above the surrounding area, this area is exposed to direct adverse wind conditions above the recommended walking comfort criterion. As such, 1.5 m high balustrades are recommended to shield the outdoor areas from adverse winds (Figure 10).
Balconies General
Whilst wind conditions on the proposed apartment balconies will frequently be acceptable for outdoor recreation, during moderate to strong winds, conditions in these areas may exceed human comfort criteria. Balcony areas on similar developments in many major Australian capital cities typically experience similar elevated wind conditions. High exposure, corner acceleration flows and standing vortices would sometimes preclude these areas from use for outdoor recreation. As a general statement, educating residents about wind conditions at high-level balconies and terraces areas during high-wind events is also recommended. Additionally, tying down loose lightweight furniture is highly recommended.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 18 of 23
MD It ,T3•£` r±:,
1.5 m high balustrade
*60
I
ViPAC • Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Figure 10: Plan of the Roof Level of the proposed development with the recommended wind control measures
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 19 of 23
ViNIC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
4 CONCLUSIONS
An assessment of the likely wind conditions at pedestrian level of the proposed development of 27-45 Best Street, Fitzroy has been made.
Vipac has carefully considered the form and exposure of the proposed development, nominated criteria for various public areas according to their function and referred to past experience to produce our opinion of likely wind conditions. Based on this assessment, the following conclusions are drawn:
• With the proposed design, the ground level footpaths and pedestrian access ways would be expected to have wind levels within the walking comfort criterion;
• With the proposed design, the wind conditions near the residential lobbies and retail store entrance areas would be expected to be within the recommended standing comfort criterion.
• With the proposed design, the alfresco dining areas on the first floor would be expected to be within the recommended sitting criterion.
• With the proposed design and recommended balustrade height increases, the wind conditions at high level terraces would be expected to be within the recommended walking criterion.
Educating occupants about wind conditions at open terrace/balcony areas during high-wind events and fixing loose, lightweight furniture on the terrace are highly recommended.
The assessments provided in this report have been made based on experience of similar situations in Melbourne and around the world. As with any opinion, it is possible that an assessment of wind effects based on experience and without detailed experimental validation may not account for all complex flow scenarios in the vicinity.
This Report has been Prepared
For
Piedimonte Developments Pty Ltd
By
VIPAC ENGINEERS & SCIENTISTS LTD.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 20 of 23
ViMC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Appendix A: ENVIRONMENTAL WIND EFFECTS
Atmospheric Boundary Layer
As wind flows over the earth it encounters various roughness elements and terrain such as water, forests, houses and buildings. To varying degrees, these elements reduce the mean wind speed at low elevations and increase air turbulence. The wind above these obstructions travels with unattenuated velocity, driven by atmospheric pressure gradients. The resultant increase in wind speed with height above ground is known as a wind velocity profile. When this wind profile encounters a tall building, some of the fast moving wind at upper elevations is diverted down to ground level resulting in local adverse wind effects.
The terminology used to describe the wind flow patterns around the proposed Development is based on the aerodynamic mechanism, direction and nature of the wind flow.
Downwash — refers to a flow of air down the exposed face of a tower. A tall tower can deflect a fast moving wind at higher elevations downwards.
Corner Accelerations — when wind flows around the corner of a building it tends to accelerate in a similar manner to airflow over the top of an aeroplane wing.
Flow separation — when wind flowing along a surface suddenly detaches from that surface and the resultant energy dissipation produces increased turbulence in the flow. Flow separation at a building corner or at a solid screen can result in gusty conditions.
Flow channelling — the well-known "street canyon" effect occurs when a large volume of air is funnelled through a constricted pathway. To maintain flow continuity the wind must speed up as it passes through the constriction. Examples of this might occur between two towers, in a narrowing street or under a bridge.
Direct Exposure — a location with little upstream shielding for a wind direction of interest. The location will be exposed to the unabated mean wind and gust velocity. Piers and open water frontage may have such exposure.
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 21 of 23
ViPAC I Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Appendix B: REFERENCES
[1 1
Structural Design Actions, Part 2: Wind Actions, Australian/New Zealand Standard 1170.2:2011
[2] Wind Effects on Structures E. Simiu, R Scanlan, Publisher: Wiley-lnterscience
[3] Architectural Aerodynamics R. Aynsley, W. Melbourne, B. Vickery, Publisher: Applied Science Publishers
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 22 of 23
ar•
•
ViPAC Piedimonte Developments Pty Ltd
27-45 Best Street, Fitzroy
Wind Impact Statement
Appendix C: DRAWING LIST
Drawings Received: May 2019
DR i\s r-,EC S-ER 1XRAWIi0 NUMBER
DRAWING TTTLE
SCALE REY
CRANING MASER 011 0.9161G TITLE SCALE ItEV
6-11,2-503 EAST FIEVATION - 2 1 250 01 01 5-11,2-104 WEST ELEJATION • I 1 250 01 01 6.7172•105 WEST ELEVATION - 2 1 ZO 01 01 A-T1731011 SECTION A.4 As Mated 01 01 6-1175101 SECTICN BB Modicaled Cl 01 A.TP3.102 SECTION CC As rdmiNd 01 01 6.7173-103 SECTION 00 As cooled 01
A-599101 BADS ASSESSMENT A:tram/5d 01 01 A-1179-102 BADS ASSESSMENT As indoca1e0 01 01 A.109-103 BADS ASSESSMENT As rocaNd 01 01 6-41,9104 BADS AS5E5510-if As Mailed 01 01 9-7179105 BADS ASSESSMENT As islcabd 01 01 0-703-106 BADS ASSESSMENT As iNkalsd 01 01 AJ04107 BADS ASSESSMENT As Mcind 01 II A-TE9.108 BADS ASSESSMENT At irdatied 01 01 6-700-109 BADS ASSESSMENT As wicaNd 01 Ot 6-7179.110 BADS ASSESSMENT As 9450t1ed 01 01 6-1179-111 BADS AssEssier As ifdlooled 01 01 A-TE9-112 BADS AS5E,S1ENT 53 indomixl 01 01 A-7179112 BADS ASSESSMENT AA nicaled 01 01 A-71,9114 BADS ASSESSAleff Am iiikaled 01 Cl A-TP.3415 BADS ASSESSMENT As miNtloi 01 01 4:114-016 BADS ASSESSMENT As MINNA 01 01 6-71:9.117 &Ds •,SSESSIAarr As Waded 01 01 0-11791121 BADS ASSESSMENT AA Ir4calml 01 01 41179110 BADS ASSESSMENT As mdcaled 01 01 A.1179120 BADS ASSESSMENT Al rgladed 01 01 A-1179-121 BADS ASSESSLEN, As =XMAS 01 01 A-79-122 BADS ASSESSMENT As fowled 01 01 A-1179-123 BADS ASSESSLENT AA =YAW 01 01 6-109.124 BADSASSESSIENT As nAca101 01 01 A.109125 BIDS ASSESSMENT ..ka ind.10.1 01
A.TP3-126 BADS ASSESSMENT MMc.214d 01 A-7P31 MATERIALS Ai odmINI 01
TP SIRES
TPBOD1
COVER PAGE
0.100002
SURVEY 1 . 500
4-100-161
GROUND FLOOR PLAN • EM61116 1 :590
A-TM-102
FIRST FLOOFt RA/1 • EXISTING 1500 500
A-11,0-103
ROOF PLAN - IFOST1110 1 500
A-TFO-111
GROIN) FLOOR FLAN. 1'500 DEMCIJOON
A-TP0-112
FIRST PLOOT1 PLAN - DEM)LITEN 1 503
A.1170143
ROOF RAN -CEMCUTION 1 . 500
A-100201
NORTH 11EVAlICN - EXISTFIG 1 250
A-1E0-232
SOWN aroma, • EXISTING 1 291
0-TP0-203
EAST ELEVATION-COSTING 1:251
A.TE0-204
NEST aEVAT/ON • EXISTING 1 • 253
A-TP0211
NORTH ELEVATION -DBADLI1ICA4 1.250
AJF0.212
SOUTH ELEVADON --OEMOUTICN 1:250
1,100.213
EAST 0EVAT1011- DEACUTION I: 250
141170-214
'NEST ELEVATION - DEMOUTEN 1:29)
AeTP1.10C
BASEMENT 03 PLAN 1 , 50)
0-1171401
BASBENT 02 PLAN 1500 500
0-T 1-102
EASaENT 01 PLAN 1 - MO
A-TP1-103
GROUND FLOOR RAN 1 : MO
A-MI-10A
FIRST ROOK PLAN 1: SCO
A-71-105
SECOND FLOOR MAN 1:500
A.TP1.106
THIRD FLOOR PLAN 1.500
ATE1-107 Fawn FLOOR PLAN 1 503
A.TP1-1011
FIFTH FLOOR PLAN 1 501
ATP! 109
SIXTH FLOOR PLAN 1 MO
A-1171.110
ROOF RAN 1. 500
ATP2•100
NORTH ELEVAT1CN 1'.250
A-1172-101
SOUTH ELEVATION 1:250
5-7P2-102
FAST ELEVATION -1 1. 250
24 May 2019
30N-19-0099-TRP-6761546-1
Commercial-In-Confidence Page 23 of 23