ville maksimainen dms600

Upload: rikie-raharja

Post on 13-Apr-2018

233 views

Category:

Documents


1 download

TRANSCRIPT

  • 7/27/2019 Ville Maksimainen DMS600

    1/45

    ABB

    -1-

    MicroSCADA Pro DMS 600-

    Distribution ManagementSystem

    Ville Maksimainen

    Sales Manager

    ABB Oy / Power Systems

  • 7/27/2019 Ville Maksimainen DMS600

    2/45

    CopyrightABB-2-

    1MRS755095

    DMS 600 Contents

    Distribution Management in General

    Features of MicroSCADA Pro DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    3/45

    CopyrightABB-3-

    1MRS755095

    DMS 600What is a Distribution Management System?

    Traditional SCADA functionalitywith on-line data integrated with:

    Distribution Network Information

    Network Database with networkmodeling down to MV/LV substationlevel (or even to low voltage network)

    Background maps

    Applications using the modelednetwork

    fault location, outage reporting, trace,locate functions, etc.

  • 7/27/2019 Ville Maksimainen DMS600

    4/45

    CopyrightABB-4-

    1MRS755095

    DMS 600 Network presentation

  • 7/27/2019 Ville Maksimainen DMS600

    5/45

    Cop

    yrightABB-5-

    1MRS755095

    DMS 600 Information Integration

    Customer data

    Location of customers

    Outage reports by customers

    Substation (relay) measurements

    Fault Impedance (reactance)

    Short circuit current

    Other existing information can be addedor imported to open DMS database

    Site information, facilities etc

  • 7/27/2019 Ville Maksimainen DMS600

    6/45

    Cop

    yrightABB-6-

    1MRS755095

    DMS 600

    Network Control Center, SCADA, DMS and other IT systems

    The complete DA system requires that all levels are integrated

    Advanced DMS functions in NCS require data from Substations andfeeders to provide the best results

    Distribution Automation

    Primary SA Secondary SA

  • 7/27/2019 Ville Maksimainen DMS600

    7/45

    Cop

    yrightABB-7-

    1MRS755095

    DMS 600 System Architecture

    MicroSCADA ProDMS 600 Server

    ExternalNetwork

    Data

    NetworkInformation

    System

    SCADA

    MicroSCADA ProSYS 600 Server

    MicroSCADA Pro

    DMS

    MicroSCADA Pro Workstation

  • 7/27/2019 Ville Maksimainen DMS600

    8/45

    Cop

    yrightABB-8-

    1MRS

    755095

    DMS 600

    Shorter outage times in the network infault and maintenance situations

    Improved quality of the power supply

    Minimum damages caused by wrongoperations (checking actionsautomatically and in simulations)

    Improved overview and manageability ofthe whole network

    Efficient use of resources

    Optimised distribution network

    New innovations from ABB can make thesupervision of electrical processes even

    easier

    With DMS you can achieve

  • 7/27/2019 Ville Maksimainen DMS600

    9/45

    Cop

    yrightABB-9-

    1MRS

    755095

    DMS 600

    With a proper outage managementyou can reduce fault outages fromhours to even less than a minute!

    Fault location tells the operatorinstantaneously the location of thefault

    Restoration support provides theoperator with a list of operations to

    be executed for a minimized outagearea

    Remote control gives the opportunityto isolate the fault and restore the

    network from the control centre Shorter outages make more revenue

    Shorter outages

  • 7/27/2019 Ville Maksimainen DMS600

    10/45

    Cop

    yrightABB-10-

    1MRS

    755095

    DMS 600 Automatic fault isolation and restoration

    A real example from 14.5.2006

    First fault is located

  • 7/27/2019 Ville Maksimainen DMS600

    11/45

    Cop

    yrightABB-11-

    1MRS

    755095

    DMS 600 Example of restoration

    DMS is opening remote controlled disconnectorKOLJ29682E to isolate fault area

  • 7/27/2019 Ville Maksimainen DMS600

    12/45

    Cop

    yrightABB-12-

    1MRS

    755095

    DMS 600 Example of restoration

    DMS is restoring power to the end of feeder by closingnormally open switch MYNT03073K

  • 7/27/2019 Ville Maksimainen DMS600

    13/45

    Cop

    yrightABB-13-

    1MRS

    755095

    DMS 600 Operation times

    Relay tripped 12:44:29

    Relay registered values to SYS 600 (~25 s)

    9600 bps, IEC 870-5-101 protocol

    DMS locates the fault and plans the switchingsequence (~30 s)

    Sequence started 12:45:36

    Fault area isolated and power restored to end of feeder

    12:46:30

    Total time from fault start 00:02:01

  • 7/27/2019 Ville Maksimainen DMS600

    14/45

    Cop

    yrightABB-14-

    1MRS

    755095

    DMS 600 Improved power quality...

    Identify the problem areas in yournetwork

    On line measurements gives

    instantaneous information of alloverloads

    Load modeling gives a chance tosimulate the load situation in the

    whole network, hour by hour

    Calculated and estimated voltagelevel in each point in the network

    Better quality => satisfied customers

  • 7/27/2019 Ville Maksimainen DMS600

    15/45

    Cop

    yrightABB-15-

    1MRS

    755095

    DMS 600 Improved overview and manageability ...

    Overview of a large geographicalarea is fast and easy

    Distribution network is digitised on

    geographical maps in up to 5 layers

    Extensive zooming and panning

    functions help you to easily navigatewith a mouse

    Dynamic colouring useful for fastsituation analysis

    Find the problem area in seconds!

  • 7/27/2019 Ville Maksimainen DMS600

    16/45

    Cop

    yrightABB-16-

    1MRS

    755095

    DMS 600 Optimise the network...

    The Distribution ManagementSystem supervises and analyses thenetwork at all times

    System calculates networkconstraints before an operation andthen informs of possibleconsequences

    An alarm is generated when a set

    value is exceeded

    Complete network analyses, withsimulation and state estimation

    No need to over-dimension thenetwork for a safety margin

  • 7/27/2019 Ville Maksimainen DMS600

    17/45

    Cop

    yrightABB-17-

    1MRS

    755095

    DMS 600 Efficient use of resources...

    Possibility to monitor and directresources for improved efficiency

    Monitor location and movement ofthe field crew with GPS

    Locate quickly the closest crew to thefault

    Fast resolution to network problems

    and faults

  • 7/27/2019 Ville Maksimainen DMS600

    18/45

    CopyrightABB-18-

    1MRS

    755095

    DMS 600 Summing up...

    Shorten the outages in best casesfrom hours to less than a minute!

    Improve quality of delivered power

    with online measurements andsimulations

    Get a better overview of thedistribution network

    No need to over-dimension thenetwork due to efficient tools fornetwork analyses

    Utilise resources more efficiently with

    field crew management

  • 7/27/2019 Ville Maksimainen DMS600

    19/45

    ABB-19-

    MicroSCADA ProDMS 600Functional Description

  • 7/27/2019 Ville Maksimainen DMS600

    20/45

    CopyrightABB-20-

    1MRS

    755095

    DMS 600 Introduction

    Network Information and Planning

    Network presentation with zooming,panning and de-cluttering

    Topological coloring with tracingand diagrams

    Network Analysis and Optimisation

    Fault location&Network RestorationCustomer Information

  • 7/27/2019 Ville Maksimainen DMS600

    21/45

    CopyrightABB-21-

    1MRS

    755095

    DMS 600 Basic Elements

    Network Database

    Data management using network

    information system

    Planning module Temporary edition mode

    Operational support

    User management

    Event/operation log

    Support for multiple districts in largenetworks

    Support for different languages

  • 7/27/2019 Ville Maksimainen DMS600

    22/45

    CopyrightABB-22-

    1MRS

    755095

    DMS 600

    Using Network Information System

    Asset database

    Geographic documentation

    Data analysis and reports

    Network calculations (load flow andshort circuits in peak load situation)

    Map printing

    Network planning

    Maintenance planning

    The network information system

    uses same database and networkpresentation as the DMS600

    Network Information and Planning System

  • 7/27/2019 Ville Maksimainen DMS600

    23/45

    CopyrightABB-23-

    1MRS

    755095

    DMS 600

    In network planning alternativenetwork structures can easily becompared regarding

    Technical acceptability

    Cost of losses

    Building costs

    Main results for each plan include

    Costs of investment and losses fromentire study period in NPV

    Material report and network reliabilityindices SAIDI and SAIFI (or T-SAIFI

    T-SAIDI) also reliability cost is estimated

    Network Planning Functionality

  • 7/27/2019 Ville Maksimainen DMS600

    24/45

    CopyrightABB-24-

    1MRS

    755095

    DMS 600 Topology Management

    Fast overview of all lines, switches,transformers, substations etc.

    Zooming

    Panning De-cluttering

    Maps in 5 layers

    Analyses the connectivity of the

    network

    Looped network

    De-energized parts

    Dynamic line coloring

  • 7/27/2019 Ville Maksimainen DMS600

    25/45

    CopyrightABB-25-

    1MRS755095

    DMS 600 Topology Management

    Identify feeder or transformer areas

    View by feeders

    View by primary transformers

    Navigate easily in complex networks Parallel network views

    Dynamic diagrams

    Trace

    downstream

    upstream

    Simulation mode

    Replaces the pins in the wall and/orthe mimics

  • 7/27/2019 Ville Maksimainen DMS600

    26/45

    Co

    pyrightABB-26-

    1MRS755095

    DMS 600

    AutomaticRestoration

    A modular Software

    FaultLocation

    NetworkAnalyses

    Low voltagenetworks

    Extended DataManagement

    RestorationSupport

    OperationsPlanning

    Extended loadmodeling Reconfiguration

    DMS 600 Base

    SCADA Interface

    Main modules

    OutageReporting

  • 7/27/2019 Ville Maksimainen DMS600

    27/45

    Co

    pyrightABB-27-

    1MRS755095

    DMS 600 Customer Information

    Customer data can be linked fromother database or imported from textfiles or spreadsheets to DMS 600database

    Customers can be queried usingseveral criteria. The foundcustomers can be easily located onnetwork map

    Detailed customer data and outagehistory are available

    A new outage report can be added

    manually

  • 7/27/2019 Ville Maksimainen DMS600

    28/45

    Co

    pyrightABB-28-

    1MRS755095

    DMS 600 Extended Data Management

    User defined object types

    Tool for searching for components inthe network

    Criterion can be anything that is inthe network database

    Graphical results easy to overview

    Data Analysis

    Filtering, sorting and statistics withMS Access

    Graphical queries (Theme map)

  • 7/27/2019 Ville Maksimainen DMS600

    29/45

    Co

    pyrightABB-29-

    1MRS755095

    DMS 600 Low Voltage Networks

    Network model can include thewhole network down to the LVnetwork and the end user

    Needed LV networks are loadedfrom database to workstationmemory

    The real-time topology and outagesin LV networks can be updated todatabase

    With LV network modeling outagereports can be produced of all

    maintenance and fault outages

  • 7/27/2019 Ville Maksimainen DMS600

    30/45

    Co

    pyrightABB-30-

    1MRS755095

    DMS 600 Extended Load Modeling

    Improves the load model for a moreaccurate presentation.

    Profile Editor for creating or editingthe load profiles for energyconsumers.

    Possible to create load profiles forcustomer segments or even largecustomers

    Adaptation of loads tomeasurements (state estimation),even to daily changes in the weather

    One week forecast for simulationand operations planning

  • 7/27/2019 Ville Maksimainen DMS600

    31/45

    Co

    pyrightABB-31-

    1MRS755095

    DMS 600 Operations Planning

    Create and simulate a switchingsequence in advance

    Two way to create a sequence:

    Automatic sequence creation Checking of technical constraints

    Learn mode (macro recording)

    Simulation of the operation before

    actual execution

    Plan Management

    Saving

    Scheduling Execution Support

    Reporting

  • 7/27/2019 Ville Maksimainen DMS600

    32/45

    Co

    pyrightABB-32-

    1MRS755095

    DMS 600 Operations Planning

    The tasks in switch orders can becustomized

    Checking, approval, work permit

    Tight Integration with MS Word tocreate documents

    MS word templates with modifiedcontent, layout and customer logos

    The end user can define and printcustomized switch order documents

    Customized list of customersaffected by an outage

  • 7/27/2019 Ville Maksimainen DMS600

    33/45

    Co

    pyrightABB-33-

    1MR

    S755095

    DMS 600 Reconfiguration

    Search for optimal networkconfiguration for loss minimization

    Two modes of reconfiguration

    All switches Only remote controlled switches

    Two algorithms available

    Single trial faster, sometimes local

    optimum

    Double trial better results

    Possibility to freeze open points

    Tool for interactive study ofoptimization results

  • 7/27/2019 Ville Maksimainen DMS600

    34/45

    Co

    pyrightABB-34-

    1MR

    S755095

    DMS 600 Fault Location

    Detects permanent faults alongfeeders, calculates the distance anddisplays the fault location on a map.

    Coloring of possible faulted lines

    Fault location based on

    Tripped circuit-breaker

    Calculated fault distance (size of

    fault current of fault reactance fromrelays via SCADA)

    Fault indicator data

    A fast fault location assists in a rapid

    restoration process

  • 7/27/2019 Ville Maksimainen DMS600

    35/45

    Co

    pyrightABB-35-

    1MR

    S755095

    DMS 600 Fault Isolation & Network Restoration

    DMS determines the switchingsequence that is required formaximum restored power supply

    Safe restoration by checkingtechnical constraints with eachoperation

    Results in list of operations to bedone

    The restoration process can bemade Automatic

    Reduces outage times from several

    hours to even less than a minute!

    DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    36/45

    Co

    pyrightABB-36-

    1MR

    S755095

    DMS 600 Outage Reports and Statistics

    Collect information about outages

    Faults

    Reclosing trips

    Maintenance outages Detailed Fault information

    Exact fault location

    Faulted component

    Get statistics of outages in thenetwork

    Whole system (SAIDI, SAIFI, etc.)

    For each customer

    DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    37/45

    Co

    pyrightABB-37-

    1MR

    S755095

    DMS 600 Network Analysis

    Calculation in the network

    Load flow based on load model

    Fault current

    Voltage drop Protection analysis

    Detection ability

    Short circuit capacity

    Selectivity

    Result representation using coloring

    Ensures an efficient and secure

    network operation

    DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    38/45

    Co

    pyrightABB-38-

    1MR

    S755095

    DMS 600 New requirements for network companies

    The society requires information ofdistribution quality

    Exact information of outage situation

    and forecasts

    For media, customers and ownorganization

    The authorities and regulatorsrequire statistics and information

    Key figures to evaluate operationalquality and efficiency

    New laws

    In many countries compensation forlong outages to all customers

    DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    39/45

    CopyrightABB-39-

    1MR

    S755095

    DMS 600 Outage information in internet/intranet

    Information to internal management andexternal parties like media

    History of the situation is stored to studythe chosen actions

    DMS 600 creates automatically

    html-document for intra- and internet

    MS Word-documents stored for laterstudies

    DMS 600 O i f i b l h

  • 7/27/2019 Ville Maksimainen DMS600

    40/45

    CopyrightABB-40-

    1MR

    S755095

    DMS 600 Outage information by telephone

    Recorded messages for each feeder

    Messages can be generated automatically

    Calling customers can try reach a person or leave a voice message

    if recorded messages do not give enough information or customer has vitalinformation to give

    The voice messages are sent as email to the operators

    DMS 600 GPS t

  • 7/27/2019 Ville Maksimainen DMS600

    41/45

    CopyrightABB-41-

    1MR

    S755095

    DMS 600 GPS support

    GPS for field crew location

    Coordinates from GPS can be used inreal-time

    Supports WGS84 and local Map

    Datums

    Continuous location of own positionwith map panning in moving vehicles

    GPS coordinates used in networkediting

    Way-points can be stored to GPSdevice

    NMEA-0183 serial communication

    standard is used to transfer points toOpera so that network can be updatedaccuratelyNMEA = National Marine Electronics Association

    DMS 600 Mi SCADA SYS 600 & DMS 600

  • 7/27/2019 Ville Maksimainen DMS600

    42/45

    CopyrightABB-42-

    1MR

    S755095

    DMS 600 MicroSCADA SYS 600 & DMS 600

    High level of integration

    Single data entry

    Tools for connecting process objectsand importing station pictures

    Tool to create manual switches adsprocess objects in MicroSCADA

    All remote control done fromMicroSCADA

    MicroSCADA process pictureopened automatically

    Integrated warnings, alarms andevents

    No need to redo what once havebeen done in MicroSCADA

    DMS 600 DMS T diti l

  • 7/27/2019 Ville Maksimainen DMS600

    43/45

    CopyrightABB-43-

    1MR

    S755095

    DMS 600 DMS vs. Traditional

    Operation planning using experienceand intuition

    Operations planned and simulated inadvance with efficient tools

    Limited information available in faultsituations

    => Laborious fault management

    => Long outage times

    Fault located immediately after the faulthappens

    Only off-line calculations available=> possible violation of technical constraints

    => overrated network

    Electrical parameters of the networkcalculated automatically

    Open point data management with pinson the wall

    Open point management with a click of amouse and dynamic colouring

    TraditionalDMS

    DMS 600 Summing up

  • 7/27/2019 Ville Maksimainen DMS600

    44/45

    CopyrightABB-44-

    1MR

    S755095

    DMS 600 Summing up

    !

    "#""""

    "

    $""

    "

    %&

    '"(

    )""

    DMS 600 Summing up

  • 7/27/2019 Ville Maksimainen DMS600

    45/45

    CopyrightABB-45-

    1MR

    S755095

    DMS 600 Summing up

    %(

    %

    &"!

    *"

    ""

    +"

    "

    $(

    $""

    $""