viking-sec 430 asphaltpumps
TRANSCRIPT
-
8/10/2019 Viking-Sec 430 AsphaltPumps
1/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2005
Section 430
Page 430.1
Issue GSERIES 34 AND 434VIKING
JACKETED ASPHALT PUMPS
FEATURES
PressureRange
To 100 PSI(6.9 Bar)
Temperature
Range
-60F. to +450F.
(-51C. to +232C.)
Viscosity
Range
31 SSU to 250,000 SSU
(1 cP to 55,000 cPs.)
Flow
Range
20 to 450 GPM
(4.5 to 102 m/Hr)
Series 434 Cutaway View
Viking Jacketed Pumps are specifically designed
for handling asphalt, heavy petroleum, coal tar, soap
solutions, and other heavy, viscous liquids which presen
temperature control problems. To overcome these
problems of maintaining a flowing state necessary forefficient handling of these liquids, the Viking jacketed
pumps feature complete jacketing of all external parts
and extra clearances on all working parts. In addition
the rotor bearing sleeve jacket prevents these heavy
viscous liquids from congealing or hardening in the
packing or mechanical seal box affording effective
shaft sealing and consequent leak-resistance.
Individual chambers surround the casing, head, and
rotor bearing sleeve and each is provided with separate
openings for connections with heating or cooling lines
See illustration at left showing location of chambers and
connections. Casings are furnished in right hand por
construction as standard (determined by location ofside port when facing shaft end of pump). Left hand por
construction on special order only
All pumps in this section come equipped with jacketing
on casing, head, and rotor bearing sleeve (except HL
model) as standard. Pumps are available with any one
or any combination, of the three jackets, but must be so
designated when ordering. A complete jacketed pump is
recommended for most installationsValues shown represent minimums or maximums. Some special construction o
consideration may be required before a cataloged pump can be applied to an
application involving maximum pressure or minimum or maximum temperature and
or viscosity.
SHAFT SEAL OPTIONSSeries 34 pumps are furnished
with packing. Series 434 pumpsmay be furnished with cartridge lipseal, single cartridge mechanicalseal, or double cartridgemechanical seal. Seal type mustbe designated when ordering.Note that steam or heat transfer oilquench is recommended for Series434 pumps.
JACKETED ROTORBEARING SLEEVE(Standard Equipment)
Jacket chamber indicated aboveaccommodates the heating orcooling agent. All chambers aresuitable for maximum steampressures of 150 PSI or 365F.
JACKETED HEAD(Standard Equipment)
Series 34 and 434 pumps areequipped with this type of head asstandard. Pumps with jacketedheads cannot be furnished withrelief valve on head. The valvemust he installed in line.
JACKETED CASING(Standard Equipment)
Complete jacketed casing sectionshown above. All pumps areavailable with right-hand ports asstandard. Left-hand on specialorder only. All jacketed featuresare furnished as standard onSeries 34 and 434 pumps.
JACKETED VALVE(On Request)
Jacketed valve on unjacketedhead can be furnished on KKthrough N pumps. Note thecomplete jacketing of the valve.Eliminates liquid solidifying in thevalve. Maximum steam pressure150# or 365F. Maximum heattransfer oil pressure 150# or 650F.
JACKETCONNECTION JACKET
CHAMBER
BUSHINGJACKET
CONNECTION
JACKETCONNECTION
JACKETCONNECTION
JACKETCHAMBER
FULL JACKETED AREASUCTION OR
DISCHARGE PORT
JACKETCONNECTION
JACKET CONNECTIONOR DRAIN
PUMPAIR RELIEF
JACKET CONNECTIONOR DRAIN
SUCTION OR
DISCHARGE PORT
PUMPDRAIN
JACKETCONNECTION
JACKET CHAMBER
Metric conversions are based on US measurements and rounded to the nearest whole number.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
2/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2005
Section 430
Page 430.2
Issue GSERIES 34 AND 434VIKING
JACKETED ASPHALT PUMPS
SPECIFICATIONS
CONSTRUCTION SERIES 34 AND 434 (HL THROUGH N SIZES)
PumpConstruction Casing Head Rotor idler
RotorShaft
IdlerPin Bushings
Shaft SealJacketedInternal
Relief ValvePackedCartridge
Seal
StandardConstruction
Iron Iron Iron Iron SteelHardened
SteelBronze Standard Lip Seal Iron
SteelFitted
Iron Iron Steel Iron
SteelHardened
SteelBronze Standard Lip Seal Iron
SPECIFICATIONS
TABLE 1 UNMOUNTED PUMP
ModelNumber
PortSize
NominalPumpRating
MaximumRecommended
DischargePressure for 100SSU and Above
Maximum
RecommendedTemperature forCataloged Pump
Steel FittedConstruction
RecommendedAbove
This Viscosity
MaximumHydrostatic
Pressure
ApproximateShipping Weight
(Pump Only)
Packed Seal Inches GPM m/hr RPM PSI Bar F C SSU cPs PSIG Bar LBs KGs
HL34 HL434 1 20 4.5 1200 100 6.9 450 232 7,500 1650 400 27.6 26 12
KK34 KK434 2 50 10 420 100 6.9 450 232 7,500 1650 400 27.6 70 32
LQ34 LQ434 2 90 20 420 100 6.9 450 232 25,000 5495 400 27.6 180 82
Q34 Q434 3 200 45 350 75 5.2 450 232 7,500 1650 400 27.6 350 160
M34 M434 4 280 64 280 75 5.2 450 232 25,000 5495 400 27.6 530 240
N34 N434 5 450 102 280 75 5.2 450 232 2,500 550 400 27.6 750 340
TABLE 2 PUMP JACKETING
Model Number
Maximum Temperature/Pressure Of Fluid in Jackets
Steam (Saturated) Heat Transfer Oil
Temperature Pressure Temperature Pressure
Packed Seal F C PSIG Bar F C PSIG Bar
HL34 HL434 365 185 150 10.4 650 343 150 10.4
KK34 KK434 365 185 150 10.4 650 343 150 10.4
LQ34 LQ434 365 185 150 10.4 650 343 150 10.4
Q34 Q434 365 185 150 10.4 650 343 150 10.4
M34 M434 365 185 150 10.4 650 343 150 10.4
N34 N434 365 185 150 10.4 650 343 150 10.4
Q Size has steel idler.Ports are suitable for use with 125# ANSI cast iron or 150# ANSI steel or ductile iron companion flanged fittings. All other tapped for standard pipe (NPT).For use at higher temperatures, consult factory for recommended materials of construction.HL Size does not have jacketed rotor bearing sleeve.
This series of pumps is available either unmounted
or as driven units. Material of construction is cast
iron with packing or mechanical seals for versatile
sealing on all models.
Dimensions for Unmounted Pumps See Page 430.4.
Performance Data for Pumps See Pages 430.7 through430.18.
Metric conversions are based on US measurements and rounded to the nearest whole number.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
3/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2005
Section 430
Page 430.3
Issue GSERIES 34 AND 434VIKING
JACKETED ASPHALT PUMPS
RETROFIT KITS
Retrofit kits are available that allow converting
new KK, LQ, Q, M, and N packed pumps (series
34) to mechanically sealed pumps (series 434). Kit
numbers are listed in the P430 price pages along with
a list of parts that come in the kit. Packed pumps
already in use can also be converted but a new rotor
and shaft assembly will most likely be required (there
will be wear on the shaft under the packing) and alsonew gaskets. Note that the kits do not include the
mechanical seal.
GENERAL INSTALLATION NOTES
1. Vent air from stuffing box before start up.
The seal may fail prematurely if this is not
done.
2. Preheat seal prior to introducing hot
product.
3. Use of low pressure (2 - 4 psi) continuous
flow steam quench on the atmospheric sideis recommended.
4. For double seals, pressurize seal chamber
before startup.
5. Do not start pump until it is fully heated.
Mechanical seal will fail almost instantly if
hard product is in the seal chamber.
6. Do not use the PS II cartridge lip seal for
filled asphalt or any product containing
abrasives.
7. When converting an existing installation to
a mechanical seal, special attention must
be placed on the condition of the pump. All
pumps should be inspected to make sure
the rotor shaft is in good condition. Any
wear due to packing will result in mechanical
seal leakage. In general, the rotor and shaft
assembly should be replaced. N size pumps
can use the same rotor bearing sleeve
assembly without modification. Outboard
face of this assembly will need to be cleaned
to make sure there is a good surface for the
mechanical seal to seal against.
8. Most asphalt pumps are V-Belt driven.
Packing is quite tolerant of any
misalignment but mechanical seals are not.
Make sure sheaves are aligned properly
(see TSM 000) and that the rotor shaft
is properly supported with a pillow block
bearing. It is also important to make sure the
mechanical seal is properly lined with the
rotor shaft. This is done at the time of seal
installation. Be sure to recheck alignment
when the rotor shaft is inserted in the pillow
block bearing.
SPECIAL INFORMATION
HL34 Cutaway View
-
8/10/2019 Viking-Sec 430 AsphaltPumps
4/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2005
Section 430
Page 430.4
Issue GSERIES 34 AND 434VIKING
JACKETED ASPHALT PUMPS
For specifications, see page 430.2.
DIMENSIONS 34 AND 434 SERIESUNMOUNTED PUMPS HLN SIZE
MODEL
NO. A B C D E F G H J K L M N O
R S T U V W
JACKET CONNECTIONS (N.P.T.)
AA BB CC DD EE
HL34
HL434
in
13.00 4.75 3.75 1.62 1.31 4.00 .88 .34 1.75 2.44 .25 1.38 N/A 6.00 11.12 N/A .75
.19 x.09
N/AN/A N/A N/A
mm 76 120 95 41 33 102 22 9 44 62 6 35 N/A 152 282 N/A 19 N/A
KK34
KK434
in2
4.88 8.00 6.00 2.88 3.00 7.00 1.00 .41 3.00 4.62 .25 1.75 N/A 9.00 18.75 4.12 1.12.25 x.12
7.12
1 N/A 1mm 124 203 152 73 76 178 25 10 76 117 6 44 N/A 229 476 105 28 181
LQ34
LQ434
in
2
7.19 10.25 6.00 2.88 3.00 7.00 1.00 .47 3.00 4.62 .12 1.75 .62 11.62 21.25 5.50 1.44.38 x.19
7.88
1 1 1mm 183 260 152 73 76 178 25 12 76 117 3 44 16 295 540 140 37 200
Q34
Q434
in
3
8.00 14.00 7.75 4.12 4.25 10.00 1.62 .75 5.00 6.50 .25 3.00 .62 13.88 33.50 6.75 1.94.50 x.25
10.62
1 1 1 1mm 203 356 197 105 108 254 41 19 127 165 6 76 16 353 851 171 49 270
M34
M434
in
4
9.50 17.25 9.50 5.00 6.25 12.00 1.44 .75 5.00 8.69 .19 4.00 .75 13.38 34.00 6.75 1.94.50 x.25
10.25
1 1 1 1mm 241 438 241 127 159 305 37 19 127 221 5 102 19 340 864 171 49 260
N34
N434
in
5
9.50 17.25 9.50 5.00 6.25 12.00 1.62 .75 5.00 8.50 .19 4.50 .75 18.12 34.00 8.50 2.44.62 x.31
10.25
2 1 1 1mm 241 438 241 127 159 305 41 19 127 216 5 114 19 460 864 216 62 260
Ports are suitable for use with 125# ANSI cast iron flanges or 150# steel or
ductile iron companion flanges or flanged fittings. All others are tapped for
standard pipe (NPT).
Minimum dimension for repacking.
HL and LQ 34 and 434 heads have two jacket openings only, (near vertical
centerline). KK, Q, M, and N head jacket opening per drawing.
DIMENSIONSThese dimensions are average and not for construction purposes. Cert ified prints on request.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
5/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
Section 430
Page 430.19
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Cast Iron Series, 224A, 224AE, 224AH, 324A,
4224A, 4224B, 4224AE, 4224AH & 4324A
Nominal
Flow
(GPM) 15 - 1600
(M3/hr.) 3.4 - 364
PressureRange
(PSI)200 PSI: 100 SSU and above
100 PSI: Below 100 SSU(Bar) 14 Bar: 20 cSt and above
7 Bar: below 20 cSt
Temp.
Range
( oF ) 60F to +650F
(N&R 60F to +450F)
( oC ) 51C to +343C
(N&R -51C to +232C)
Viscosity
Range
(SSU) 28 SSU to 2,000,000 SSU
(cSt) 0.1 cSt to 440,000 cSt
Operating Range:
Heavy-Duty, Foot-Mounted Internal Gear
Pumps With Multiple Seal Options
Jacketed Pump(shown: KK4224A with optional anged port)
Jacketing
Jacketed pumps provide a cavity, or jacket, on the externalwall of the pump through which steam or heat transfer liquidcan be passed to control the temperature of the uid in thepump. The heat transfer medium ows in a closed loop backto the boiler or heater. Applications include melting ambientemperature solids like asphalt which solidify in the pumpwhen it cools, and maintaining precise temperature control inprocesses like manufacturing polymers and epoxy resins.
Standard-Jacketed PumpsStandard-Jacketed pumps include series 224A, 224AE,224AH, 4224A, 4224AE, 4224AH and 4224B. They feature
jacketing on the head and bracket only, and are typicallyused for melting ambient temperature solids.
Standard-Jacketed Pump Cutaway H4224A
Jacketed Bracket Jacketed Head
Relief Valve Congurations
Jacketed pumps are provided with a jacketed head with norelief valve as standard. Integral pressure relief valves in
jacketed and non-jacketed congurations are available onL through N sizes, but require a non-jacketed valve-typehead.
The N 324A, and 4324A, pumps are standard with ajacketed bracket and non-jacketed head and non-jacketedrelief valve. A jacketed head, or a jacketed relief valve withnon-jacketed valve-type head, is available as an option.
The R 324A, and 4324A, pumps are standard with a
jacketed bracket, a jacketed head and a non-jacketed reliefvalve. For RS models contact the factory for assistance
with jacketing options.
Porting and Sealing
A variety of opposite and 90port congurations areavailable, including top suction with bottom or side dischargedesigns typically mounted at the bottom of a tank or reactor.
Jacketed port options for steam or heat transfer liquidinclude threaded, anged and weld neck congurations.Viking will provide custom welded steam or hot oil angeconnections upon request.
The Universal Seal design allows the use of packing,component seals or cartridge seals. Seal plans, including
API plan 53 and 54, are available.
R4323A
Jacketed Head with
Non-Jacketed Relief Valve
Shown
N4324A
Non-Jacketed Head with
Coverplates Shown
ATEX Certification available.
The jacketed cast iron Universal Seal pump is commonly
used for asphalt applications. Now the details regarding
these jacketed pumps have been added to this section for
convenience.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
6/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
Section 430
Page 430.20
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Note on Field 4 that only the N, R and RS sizes are the foot mount with jacketed bracket (3). All other sizes are available with ajacketed (2) bracket. The N size is standard with a jacketed bracket and non-jacketed head and non-jacketed relief valve, while the
R size is standard with a jacketed bracket, a jacketed head, and a non-jacketed relief valve. There are relief valve options available
on those pump models designed to accept a relief valve. Options include a jacketed relief valve for the N pump (only available with
the non-jacketed head). A non-jacketed relief valve is available for the R pump.
The Universal Seal series comes in several different versions depending on the type and location of the sealing device. The L, LQand LL size also offer two shaft diameter options. The model numbering scheme is illustrated in the table below, with the cast iron,
jacketed series pumps.
Model Number Scheme
PackedStufng
Box Seal
Rated for
Higher Flow
Behind- the-
Rotor Seal
H224A H4224A NA H4224B
HL224A HL4224AHL224AH
HL4224AHHL4224B
K224A K4224AK224AH
K4224AHK4224B
KK224A KK4224AKK224AH
KK4224AHKK4224B
L224A
L224AE
L4224 A
L4224AE
L224AH
L4224AHL4224B
LQ224A
LQ224AE
LQ4224A
LQ4224AE
LQ224AH
LQ4224AHLQ4224B
LL224A
LL224AE
LL4224A
LL4224AENA LL4224B
LS224A LS4224ALS224AH
LS4224AHNA
Q224A Q4224A NA NA
QS224A QS4224A NA NA
N324A N4324AN324AH
N4324AHNA
R324A
RS324A
R4324A
RS4324ANA NA
Model Number Key
Note that on L, LQ and LL pumps with the AE or Bdesignation at the end of the model number will have1 5/8 shaft as standard, the L, LQ and LL pumps endingin A will have a 1 7/16 shaft standard as illustratedin the chart below. The B designation i.e. L4224B orKK4224B, are replacements for similar size 4225 models(see dimensional drawings for shaft coupling sizes).The AE designation, i.e., LQ224AE is dimensionallyinterchangeable with a LQ224A or LQ225 except that theAE model has a 1-5/8 shaft at the drive end versus 1-7/16for the other models. The AE version is recommended insevere-duty applications or those where stress corrosionmay be encountered. (Dimensional drawings are locatedon pages 22 and 23)..
Size:
H
HL
K
KK
L
LQ
LL
LS
Q
QS
N
RRS
ShaftSeal:4 = Mechanical
Seal
blank = packing
Jacketing:2 = jacketed3 = foot mount casing
w/ jacketed bracket
2L Q - 2 4 A H
Materials ofContstruction:4 = Cast Iron
Seal Location:
A = Stuffing Box with Universal Seal
DesignB = Behind-the-Rotor
AE= Stuffing Box seal with -5/8" Shaft
Diameter (L, LQ and LL sizesonly)
See dimension drawings for shaftdiameter at coupling.
Field2
Field3
Field4
Field5
Field8
Field7
Field6
Field1
H = High Flow
Model Sizes
L, LQ, LL
Shaft Seal
Dimension
U
Dimension
224A, 4224A
224AH, 4224AH1-7/16 1-1/8
224AE, 4224AE
4224B1-5/8 1-7/16
These models have been performance tested and rated for higher ow servicespecically for asphalt applications. Performance curves can be electronically
generated with the Viking Pump Selector Program. For authorized distributors,
this program is available at www.idexconnect.com (Security passwords are
required) and is found listed under the Products tab
-
8/10/2019 Viking-Sec 430 AsphaltPumps
7/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
KK, LS, QS, N and RS sizes have ductile iron rotor, ASTM A536 Grade 60-40-18. Steel tted Q and QS sizes have steel idler. H and HL sizes have powdered metal idler, MPIF Std 35 FC-0208-50. H-LL 4224B (Behind-the-Rotor) pumps have bronze bracket bushing with Buna N seal, carbon graphite for Viton or PTFE seals. Material specication for HL steel rotor is AISI 8620, LS steel rotor is ASTM A148 80-50.
Materials of Construction - All Series
Section 430
Page 430.21
Issue A
CONSTRUCTION SERIES 224A, 224AH, 4224A, 4224AH, 224AE, 4224AE, 4224B,
324A, AND 4324A (ALL SIZES)
PumpConstruction Casing
Head andJacketed
Head Plate Bracket Rotor Pressure
Relief Valve Idler Rotor Shaft Idler Pin
Shaft Sealing
Packed Mech. Seal
StandardConstruction Cast Iron
ASTM A48,
Class 35B
Cast Iron
ASTM A48,
Class 35B
Cast Iron
ASTM A48,
Class 35B
Cast Iron
ASTM A48,
Class 35BCast Iron
ASTM A48,
Class 35B
Cast Iron
ASTM A48
Class 35BSteel
ASTM A108,
Grade 1045
Hardened Steel
ASTM A108,
Grade 10L45
Standard PTFE Seal
SteelFitted
Steel
ASTM A108,
Grade 1045
Iron Standard PTFE Seal
PumpConstruction
Bushings
Packed Mechanical Seal
StandardConstruction
Idler Bracket Idler Bracket
Bronze
ASTM B584 (B505),
Alloy C93700
Bronze
ASTM B584
(B505), Alloy
C93700
Carbon Graphite
Carbon GraphiteSteelFitted
NOTE: Sizes H through M, relief valve cannot be used on pump with jacketed head plate or jacketed head. The N s ize is standard with a jacketed bracket and non-jacketed head and
non-jacketed relief valve. The R is standard with a jacketed bracket, jacketed head, and non-jacketed relief valve. RS size relief valve not available. Contact factory for jacketing
options
Model
PortsNominal Pump Rating
(750 SSU and below)
Maximum.
Hydrostatic
Pressure
Maximum.
Discharge
Pressure
Maximum
Recommended
Temperature for Standard
Pump
Steel Fitted
Recommended
Above
Approximate
Shipping
Weight with
Valve
Packed
Stufng Box
Mechanical.
Seal
Behind
the Rotor
SealIn. mm GPM m3/hr RPM PSIG BAR PSIG BAR
Packed
Mechanical
SealSSU cSt lbs. kG
F C F C
H224A H4224A H4224B 1.5 38 15 3.4 1750 400 28 200 14 450 232 450 232 25,000 5,500 42 19
HL224A HL4224A HL4224B 1.5 38 30 6.8 1750 400 28 200 14 450 232 450 232 7,500 1,650 45 21
HL224AH HL4224AH NA 1.5 38 50 11 2900 400 28 125 9 450 232 450 232 7,500 1,650 45 21
K224A K4224A K4224B 2 50 75 17 780 400 28 200 14 450 232 450 232 25,000 5,500 120 55
K224AH K4224AH NA 2 50 90 20 950 400 28 125 9 450 232 450 232 25,000 5,500 120 55
KK224A KK4224A KK4224B 2 50 100 23 780 400 28 200 14 450 232 450 232 25,000 5,500 125 57
KK224AH KK4224AH NA 2 50 120 27 950 400 28 125 9 450 232 450 232 25,000 5,500 125 57
L224A/AE L4224A/AE L4224B 2 50 135 30 640 400 28 200 14 450 232 450 232 25,000 5,500 175 80
L224AH L4224AH NA 2 50 210 48 950 400 28 125 9 450 232 450 232 25,000 5,500 175 80
LQ224A/AE LQ4224A/AE LQ4224B 2.5 65 135 30 640 400 28 200 14 450 232 450 232 25,000 5,500 190 87
LQ224AH LQ4224AH NA 2.5 65 210 48 950 400 28 125 9 450 232 450 232 25,000 5,500 190 87
LL224A/AE LL4224A/AE LL4224B 3 75 140 32 520 400 28 200 14 450 232 450 232 2,500 550 200 91
LS224A LS4224A NA 3 75 200 45 640 400 28 200 14 450 232 450 232 75,000 16,500 210 96
LS224AH LS4224AH NA 3 75 230 52 720 400 28 125 9 450 232 450 232 75,000 16,500 210 96
Q224A Q4224A NA 4 100 300 68 520 400 28 200 14 450 232 450 232 7,500 1,650 580 265
QS224A QS4224A NA 6 150 500 114 520 400 28 200 14 450 232 450 232 75,000 16,500 580 265
N324A N4324A NA 6 136 600 136 350 400 28 200 14 450 232 300 132 75,000 16,500 810 376
N324AH N4324AH NA 6 136 685 155 420 400 28 125 9 450 232 300 132 75,000 16,500 810 376
R324A R4234A NA 8 200 1100 250 280 400 28 200 14 450 232 300 132 25,000 5,500 1435 650
RS324A RS4324A NA 10 254 1600 364 280 400 28 125 9 450 232 300 132 25,000 5,500 1580 718
Specications
Port sizes are inch standard, not metric design or size. See p. 630.16 for other port size options.Ports are tapped for standard (NPT) pipe.Ports are suitable for use with 125# ANSI cast iron anges or anged ttings. For maximum recommended discharge pressures when handling other viscosities and/or other speeds, see performance curves. If suction pressure exceeds 50 PSIG, consult factory. Higher temperatures can be handled with special construction, consult factory. Temperature based on PTFE seal as standard. Lower temperature limits may be required when using other seal elastomers.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
8/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
Section 430
Page 430.22
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Dimensions - H through Q Sizes Cast Iron Construction Jacketed Pumps
NOTE: Dimensions R through FF on next page
Model Number
A(in)
B C D E F G H JK L M N O
PackedStufng BoxSeal
Behindthe RotorSeal
H224A
HL224AHL224AH
H4224A
HL4224AHL4224AH
H4224B
HL4224B 1.5
in 3.00 4.75 3.50 2.75 2.25 6.75 3.50 0.47 0.99 3.38 2.38 4.00 0.56
mm 76.2 120.6 88.9 69.8 57.1 171.4 88.9 11.9 25.1 85.8 60.5 101.6 14.2
K224A
K224AH
KK224A
KK224AH
K4224A
K4224AH
KK4224A
KK4224AH
K4224BKK4224B
2in 5.12 8.00 5.50 4.00 2.75 9.25 4.00 0.53 1.42 3.00 4.00 5.75 0.62
mm 130.0 203.2 139.7 101.6 69.8 234.9 101.6 13.5 36.1 76.2 101.6 146.0 15.7
L224AL224AHL224AE
L4224AL4224AHL4224AE
L4224B 2in 6.50 10.25 7.00 4.38 4.00 10.00 5.38 0.53 2 3.38 5.12 6.56 0.62
mm 165.1 260.3 177.8 111.3 101.6 254 136.7 13.5 50.8 85.9 130.0 166.6 15.7
LQ224ALQ224AHLQ224AE
LQ4224ALQ4224AHLQ4224AE
LQ4224B 2.5in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 2 3.38 5.12 6.56 0.62
mm 182.6 260.3 177.8 111.3 101.6 254 136.7 13.5 50.8 85.9 130.0 166.6 15.7
LL224ALL224AE
LL4224ALL4224AE
LL4224B 3in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 2 3.38 5.12 6.56 0.62
mm 182.6 260.3 177.8 111.3 101.6 254 136.7 13.5 50.8 85.9 130.0 166.6 15.7
LS224ALS224AH
LS4224ALS224AH
NA 3in 7.19 10.25 7.00 4.38 4.00 10.00 5.38 0.53 2.55 4.75 5.12 7.40 0.62
mm 182.6 260.3 177.8 111.3 101.6 254 136.7 13.5 64.8 120.6 130.0 188.0 15.7
Q224A Q4224A NA 4in 8.25 14.00 8.75 4.12 4.00 10.00 6.00 0.69 3.58 6.62 7.00 7.62 0.75
mm 209.5 355.6 222.2 104.6 101.6 254 152.4 17.5 90.9 168.1 177.8 193.5 19.0
Dimensions given are for guidance only andshould not be used for installation purposes.Certifed dimensions will be supplied on request.
Port(s) tapped for standard (NPT) pipe.
Port(s) suitable for use with 125# ANSI cast iron companion flanges or flanged ttings.
K dimension for Cast Iron L, LQ and LL sizes is for A models. K dimension for L, LQ and LL size 224AE, 2224AE and 2224B pumps is 1.44 (36.6mm).
-
8/10/2019 Viking-Sec 430 AsphaltPumps
9/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Ports for steam or hot oil jacketing are inch standard NPT threads. Metric (mm) equivalents are for information only, and do not indicate a metric thread size. T dimension show for Cast Iron sizes L, LQ and LL is for A models.Dimension for L, LQ and LL size 224AE, 4224AE and 4224B pumps is 2.35 (59.7 mm).U dimension shown for Cast Iron sizes L, LQ and LL is for A models. U dimension for L, LQ and LL size 224AE, 4224AE and 4224B pumps is 1.44 (36.6 mm). V dimension shown for Cast Iron sizes L, LQ and LL is for A models. V dimension for L, LQ and LL size 224AE, 4224AE and 4224B pumps is 0.38 X 0.19 (9.6X 4.83 mm).
BB Dimension for Q223A and Q227A is 1(25.4 mm).
Model Number
P R ST
U
V
W X Y
AA
BB
CC DD EE FFPacked
Stufng Box
Seal
Behind
the Rotor
Seal
H224A
HL224AHL224AH
H4224A
HL4224AHL4224AH
H4224B
HL4224B
in 0.62 4.00 12.06 1.62 0.75 .19 X .09 4.04 1.80 1.83 0.75 0.50 0.94 2.41 5.75 2.30
mm 15.7 101.6 306.3 41.1 19.0 4.83 X2.29 102.6 45.7 46.5 19.0 12.7 23.9 61.2 146.0 58.4
K224A
K224AH
KK224A
KK224AH
K4224A
K4224AH
KK4224A
KK4224AH
K4224B
KK4224B
in 0.62 5.75 16.38 2.25 1.12 .25 X .12 7.00 3.38 2.75 1.25 1.25 1.75 3.25 6.75 2.92
mm 15.7 146.0 416.0 57.1 28.4 6.35 X .05 177.8 85.9 69.8 31.7 31.7 44.4 82.5 171.4 74.2
L224A/AH
L224AE
L4224A/AH
L4224AEL4224B
in 0.62 6.56 17.88 2.25 1.12 .38 X .19 7.18 4.62 3.25 1.25 1 3.00 3.81 6.75 2.93
mm 15.7 166.6 454.2 57.1 28.4 9.65 X .83 182.4 117.3 82.5 31.7 25.4 76.2 96.8 171.4 74.4
LQ224A/AH
LQ224AE
LQ4224A/AH
LQ4224ALQ4224B
in 0.62 6.56 17.88 2.25 1.12 .38 X .19 7.18 4.62 3.25 1.25 1 3.00 3.81 6.75 2.93
mm 15.7 166.6 454.2 57.1 28.4 9.65 X .83 182.4 117.3 82.5 31.7 25.4 76.2 96.8 171.4 74.4
LL224A/AH
LL224AE
LL4224A/AH
LL224AELL4224B
in 0.62 6.56 17.88 2.25 1.12 .38 X .19 7.18 4.62 3.25 1.25 1 3.00 4.31 6.75 2.93
mm 15.7 166.6 454.2 57.1 28.4 9.65 X .83 182.4 117.3 82.5 31.7 25.4 76.2 109.5 171.4 74.4
LS224A/AH LS4224A/AH NAin 0.62 7.00 19.25 3.50 1.44 .38 X .19 7.72 4.40 3.30 1.25 1 3.00 4.50 7.00 4.03
mm 15.7 177.8 488.9 88.9 36.58 9.65 X .83 196.1 111.8 83.8 31.7 25.4 76.2 114.3 177.8 102.4
Q224A Q4224A NAin. 1.00 6.62 23.75 4.50 1.94 .50 X .25 11.25 5.50 4.50 1.5 1.25 --- 4.57 8.38 5.35
mm 25.4 168.1 603.2 114.3 49.3 12.70 X .35 285.7 139.7 114.3 38.1 31.7 --- 116.1 212.8 135.9
Section 430
Page 430.23
Issue A
-
8/10/2019 Viking-Sec 430 AsphaltPumps
10/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
Section 430
Page 430.24
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Dimensions - QS Size Jacketed Series 224A and 4224A
Other Dimensions
BB* 1.25 (31.75)
DD 5.57 (141.48)
GG 4.12 (105)
* Ports for steam or hot oil jacketing are inch standard NPT threads. Metric (mm) equivalents are for information only, and do not indicate a metric thread size.
Dimensions - N, R & RS Sizes Jacketed Series 324A and 4324A
Model NumberA
(in)B C D E F G H J K M N O P R S T U V W X Y Z
Packed StufngBox Seal
N324A N4324A
6
in 9.75 17.25 9.50 5.00 6.25 8.69 1.62 0.69 4.50 12.00 4.50 1.00 3.00 26.00 36.50 6.00 2.44 .62x.31 8.63 0.69 n.a. 18.94
mm 24.6 438.1 241.3 127.0 158.7 220.7 41.1 17.5 114.3 304.8 114.3 25.4 76.2 660.4 927.1 152.4 62.015.74x7.87
219.2 17.5 n.a. 481.0
R324A R4324A
8
in 14.25 24.50 13.25 6.75 7.00 10.56 2.31 0.78 6.00 16.00 5.62 1.00 4.50 28.75 41.00 6.62 3.44 .88x.44 12.00 0.69 1.25 19.25
mm 361.9 622.3 336.5 171.4 177.8 268.2 58.7 19.8 152.4 406.4 142.7 25.4 114.3 730.2 1041 168.1 87.422.35
x11.18304.8 17.5 31.7 488.9
RS324A RS4324A
10
in 14.25 24.5 13.25 6.75 7.00 13.12 4.81 0.88 6.00 16.46 8.12 1.30 4.50 28.55 43.49 6.62 3.44 .88x.44 12.00 0.88 1.25 19.25
mm 361.9 622.30 336.5 171.4 177.8 333.24122.17 22.35 152.4 418.08206.24 33.02 114.3 725.17 1104.64 168.1 87.422.35x11.18
304.8 22.35 31.7 488.9
Ports are suitable for use with 125# ANSI cast iron (324A/4324A)
NOTE: The N size is standard with a jacketed bracket and non-jacketed head and non-jacketed relief valve. The R size is standard with a jacketed bracket, a
jacketed head, and a non-jacketed relief valve. RS contact factory for jacketing options.
Dimensions given are for guidance only andshould not be used for installation purposes.Certifed dimensions will be supplied on request.
-
8/10/2019 Viking-Sec 430 AsphaltPumps
11/12VIKING PUMP
A Unit of IDEX Corporation Cedar Falls, IA 2007
Section 430
Page 430.25
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Port(s) tapped for standard (NPT) pipe.
Port(s) suitable for use with 125# ANSI cast iron companion flanges or flanged ttings.
Port(s) suitable for 150# ANSI steel or stainless steel companion flanges or flanged ttings.
Port(s) suitable for 300# ANSI steel or stainless steel companion flanges or flanged ttings. Non-Rotatable Ports at 90 degree angle, contact factory for available orientation (right hand or left hand).
Opposite Ports
90port arrangement for Right Hand inlet (viewed from shaft end).Contact factory for flange details (e.g. Flat face or raised face anges).
* Standard-Jacketed pumps have a jacketed bracket and head, but the casing is not jacketed. They have the series designations 224A/4224A & AE, 224B/4224B and224AH/4224AH. Also the N324A, and N4324A, are standard with a jacketed bracket and non-jacketed head and relief valve, while the R324A, and R4324A, are
standard with a jacketed bracket and jacketed head and non-jacketed relief valve. The RS324A and RS4324A contact the factory for jacketing options.
Model Number Standard Jacketed
Pumps Standard
Ports
Standard Jacketed Pumps
Optional PortsPacked Stuffing Box Seal
Behind the
Rotor Seal
H224A H4224A H4224B
1.5 1.5, 2HL224A HL4224A HL4224B
HL224AH HL4224AH n.a.
K224A K4224A K4224B2 2,2.5 ,3 ,4
K224AH K4224AH n.a.
KK224A KK4224A KK4224B2 2,2.5 ,3 ,4
KK224AH KK4224AH n.a.
L224A/AE L4224A/AE L4224B2 -------
L224AH L4224AH n.a.LQ224A/AE LQ4224A/AE LQ4224B
2.5 3, 4 , 6 LQ224AH LQ4224AH n.a.
LL224A/AE LL4224A/AE LL4224B 3 4, 5
LS224A LS4224A n.a.3 4
LS224AH LS4224AH n.a.
Q224A Q4224A n.a. 4 3, 5, 6
QS224A QS4224A n.a. 6 6
N324A N4324A n.a. 6 5
N324A N4324A n.a. 6 5
R324A R4324A n.a. 8 6
RS324A RS4324A n.a. 10
Optional Casings - Standard-Jacketed* Pumps
-
8/10/2019 Viking-Sec 430 AsphaltPumps
12/12
Section 430
Page 430.26
Issue A
VIKING HEAVY DUTY JACKETED ASPHALT PUMPS (Cast Iron)SERIES 224A, 224AE, 224AH, 4224A, 4224AE, 4224AH,
4224B, 324A, 324AH, 4324A, and 4324AH
Stufng Box Seal Chamber Dimensions
Pump Size A B C D E F G H J K L M N O P R
H & HL
In 1.12 2.00 2.41 2.22 1.90 1.03 2.27 4.50 3.00 to 3.50 2.00 2.50 4.00 0.66 5/16 4.47 1/8
mm 28.6 50.8 61.2 56.4 48.3 26.2 57.7 114.3 76.2 to 88.9 50.8 63.5 101.6 16.8 7.9 113.5 3.2
K & KK
In 1.44 2.31 3.00 3.13 2.25 1.25 3.00 5.25 3.50 to 4.50 2.50 3.00 5.00 0.38 7/16 5.25 1/4
mm 36.5 58.7 76.2 79.5 57.1 31.7 76.2 133.3 88.9 to 114.3 63.5 76.2 127.0 9.7 11.1 133.3 6.3
L, LQ, & LL
(A)
In 1.44 2.31 3.00 3.13 2.25 1.25 4.00 5.25 3.50 to 4.50 2.50 3.00 5.00 0.44 7/16 5.25 1/4
mm 36.5 58.7 76.2 79.5 57.1 31.7 101.6 133.3 88.9 to 114.3 63.5 76.2 127.0 11.2 11.1 133.3 6.3
L, LQ, & LL
(AE)
In 1.62 2.375 3.00 3.13 2.25 1.16 3.52 5.25 3.50 to 4.50 3.00 3.00 5.00 0.46 7/16 5.25 1/4
mm 41.3 60.3 76.2 79.5 57.1 29.5 89.4 133.3 88.9 to 114.3 76.2 76.2 127.0 11.7 11.1 133.3 6.3
LS
In 1.62 2.375 2.80 2.70 2.25 1.16 3.52 5.25 3.25 to 4.50 3.00 2.80 5.00 0.46 7/16 5.25 1/4
mm 41.3 60.3 71.1 68.6 57.1 29.5 89.4 133.3 82.5 to 114.3 76.2 71.1 127.0 11.7 11.1 133.3 6.3
Q & QS
In 2.44 3.42 4.50 4.00 2.50 1.53 4.10 6.75 5.50 to 6.25 3.20 4.50 7.20 0.56 5/8 6.75 1/4
mm 61.9 87.0 114.3 101.6 63.5 38.9 104.1 171.4 139.7 to 158.7 81.3 114.3 182.9 14.2 15.9 171.4 6.3
NIn 3.44 4.69 - 5.56 1.65 - 4.91 8.81 6.75 - - - - 3/4 9.00 1/4
mm 87.3 119.3 - 141.2 41.9 - 124.7 223.8 171.4 - - - - 19.0 228.6 6.3
RIn 4.50 5.75 - 5.56 1.53 - 4.79 9.81 7.75 - - - - 3/4 9.81 1/4
mm 114.3 146.1 - 141.2 38.9 - 121.7 249.2 196.8 - - - - 19.0 249.2 6.3
RSIn 4.50 5.75 - 5.56 1.53 - 4.79 9.81 7.75 - - - - 3/4 9.81 1/4
mm 114.3 146.1 - 141.2 38.9 - 121.7 249.2 196.8 - - - - 19.0 249.2 6.3
Bracket is counter bored to a diameter of 2.687 inches (68.25 mm), 0.12 inches (3.05 mm) deep from stufng box face. Studs are used in place of cap screws.