Page 73 STD-SEMCO-E-LA-0001 Rev. A
Victor floodlight VL71
Floodlight for use in explosive atmosphere, gas zone 2 and dust environments, zone 22.
Applications• Onshore/offshoreoilandgasindustry• Securityandperimeterlighting• Harsh and corrosive environments• FPSO and FSO vessels
Product characteristics• Lightweight construction• Marinegradestainlesssteelbodyandtoughenedglasscover• Highefficiencysymmetricalreflector• 150, 250 and 400W HPS & MBI, 500W T/HAL• Quickreleasefastenersforeasyrelampingandmaintenance• Suspended cover front
Certification and approval
ATEXCertificateBaseefa07ATEX0119X II 3GD EX nR II
(Refer to table for T class and ambient)
Ambient temperature range-50°C to +60°C(Dependentonlamptypepleaserefertotemperaturenoteoverleaf)
Ingress protection to IP66 and IP67
Lighting
Page 74STD-SEMCO-E-LA-0001 Rev. A
Technical specifications:
Lamp typeSON/MBI = 400W, 250W, 150W tubulartungsten halogen 500WPower supply220V, 230V, 240V, or 254V 50Hz Power factorBetter than 0.85TerminalsSuitable for looping up to 6 mm2 conductors Internalandexternalearthfittedasstandard.Cable entriesTwo-entryterminalboxwithM20x1.5tappingOther entries available .
MaterialsMainEpoxypaintedmarinegradestainless steel. Lamp glass: Toughened glassGasket: Silicone rubberExternal fasteners: Stainless steel.Weight 150W-19kg250W - 20.5 kg400W - 21 kg500W - 16.5 kgMountingsStainless steel stirrup bracket
Std. cat. Ref Wattage Lamptype Lamp holder T class Ambient °C Order code
REGN/150/MS 150 HPS&Metal Halide E40 T4 60 8003759REGN/250/MS 250 HPS&Metal Halide E40 T3 55 8003734REGN/400/MS 400 HPS&Metal Halide E40 T3 50 8003743REGN/500/MS 500 Tungsten halogen E40 T3 / T2 45/60
110/120V Cat Ref REGN/150/MS/120* 150 HPS&Metal Halide E40 T3 55REGN/250/MS/120* 250 HPS&Metal Halide E40 T3 55REGN/400/MS/120** 400 HPS&Metal Halide E40 T3 55*c/wIECcontrolgear110/120Vsupply**c/wTransformerboxfor110/120Vsupply(IECcontrolgearfitted)
Options – Suffix to catalogue ref.
/60 60Hz/M25 M25 entries/N Narrowbeamreflector/TI Timed cut-out ignitor/WA Suitable for wire guard or anti-glare shield
AccessoriesPole mount bracket S2400-0001Anti-glare shield S8644-0002(Luminairerequires/WAsuffixwhenordering)Wire guard S8644-0004(Luminairerequires/WAsuffixwhenordering)Spigot mount bracket S2400-0007
Lighting
Page 75 STD-SEMCO-E-LA-0001 Rev. A
Victor Floodlight VL64A Equal Plus
Floodlight for use in explosive atmosphere, gas zones 1 and 2, and dust environments, zones 21 and 22.
Applications• Onshore/offshoreoilandgasindustry• Securityandperimeterlighting• Tank farms• Harduous industrial environments
Product characteristics• Excellent photometric properties, wide or narrow beam• Integral control gear• Captive front cover bolts• Hinged cover• Ex´e´ terminal chamber as standard• Twin arc tube lamps
Certification and approval
ATEXCertificateBaseefa058ATEX0228II 2GD EEx de IIB T*
Ambient temperature range-20°C≤Tamb≤+*°C(See details of T ratings, lamps and ambient temperature variants)
Ingress protection to IP66 and IP67.
Lighting
Page 76STD-SEMCO-E-LA-0001 Rev. A
Technical specifications:
Lamp typeSON/T 400W, 250W, 150WMBI-T 400W, 250W, 150WMBFU 400W and 250WTungsten Halogen 500WPower supply220V, 230V, 240V, or 254V 50Hz available via amultitapped ballast.Allluminairesfactorysetto240V50Hz.60Hz versions also available.Power factorBetter than 0.85TerminalsSuitable for looping up to 6 mm2 conductors Internal andexternalearthfittedasstandard.Cable entriesTwo-entryterminalboxwithM20x1.5tappingOther entries available .
MaterialsMainLM6aluminiumwithepoxypaintfinishasstandard.Lamp glass: Toughened soda lime glass plate.External fasteners: Stainless steel.Tungsten fasteners: Stainless steelWeight Discharge lamp versions - 31.0 kgMountingsStirrup bracket pre-drilled with 2 holes, dia. 13 mm.Complete with locking and aiming quadrant.Beam patternsNarrow or wide beam patterns available.Patternedorplainreflectorscombinedwithforwardandrear lamp positions provide the beam pattern options.MBFU lamp must be used in the forward lamp position for wide beam patterns.
Std. cat. Ref Wattage Lamptype Lamp holder T class T °C dust Ambient °C Order code
64ED/150/MS 150 HPS&Metal Halide E40 T4 128 70 800369064ED/250/MS 250 HPS&Metal Halide E40 T3 145 55 800375664ED/400/MS 400 HPS&Metal Halide E40 T3 160 55 800375764ED/500/TH 500 Tungsten halogen E40 T3 175 55
Options – Suffix to catalogue ref.
/60 60Hz/M25 M25 entries/N Narrowbeamreflector
AccessoriesPole mount bracket S6428-0001Anti-glare shield S6428-0002(cannot be used with wire guard)Wire guard S6428-0003(cannot be used with anti-glare shield)
Lighting
Page 77 STD-SEMCO-E-LA-0001 Rev. A
IMT Floodlight IQL Centaur 85
Floodlight for use on Helidecks and in harzardous areas, gas zone 1 and dust enviroments, zone 21.
Main Characteristics• 100,000 'maintenance free' operational hours.• Luminaireis sealed for life• Shock and vibration resistant• Patented construction
Specification/Technical DataLight source QL (Induction)Luminousflux(lightsource) 6200lmLuminousflux(lightsource)lm/w 73lm/Wlamp lumen depreciation 30% loss after 60,000 hoursHousing: Stainless Steel 316L (AISI)Lens: Clear Borosilicate GlassReflector: ExternalStainlessSteelAISI316LhelideckreflectorColour Rendering: RA>80Lamp Colour: White (colour830)Ingress Protection: IP66Voltage Range: 200-277Vac/dc 50/60Hz +/-6% or 100-120Vac/dc +/-6%Power: 85W(Re)ignition: InstantBurning position Universal Ambient Temperature: -40C to +40CPowerFactor/Cosφ: >0.92Termination: Standard -Junction Box c/w 3xM25 entries, Terminals suitable for max 4 mm2, Suitable for through wiringIEC protection classes Class I
Certification details EX versionATEXClassification: GroupII,Category2,GasandDusAreaClassification: Category2(Zone1and21)Certificate: KEMA02ATEX1257XMarking: EX II 2 GD EExme II T4 T135C
Lighting
Page 78STD-SEMCO-E-LA-0001 Rev. A
OptionsHigh Temperature: Up to +55C AmbientLamp Colour: Warm White (colour827) Cool White (colour840) ClearSkyMounting Brackets: On requestIndustrial version: IP66HazardousAreas: ATEXCategory2(Zone1andZone21)
Type Version Wattage Voltage External Reflector
Connection Weight
EQNI4BC3C241 EX 85W 230V Standard E012129Junctionboxw/3M25Entries 11Kg
EQNI4BC3C441 IP66 85W 230V Standard E012129Junctionboxw/3M25Entries 11Kg
EQNI4BC4C241 EX 85W 230V Extended E012129Junctionboxw/3M25Entries 12Kg
EQNI4BC3C441 IP66 85W 230V Standard E012129Junctionboxw/3M25Entries 12Kg
Dimensions:
App
rox.
340
225
170
25
2
12
Approx. 375
Lighting
Page79STD-SEMCO-E-LA-0001 Rev. A
IMT Floodlight IQL Aquarius
Main Characteristics• 100,000 'maintenance free' operational hours.• Luminaireis sealed for life• Shock and vibration resistant• Patented construction
Specification/Technical DataHousing Stainless Steel 316L (AISI)Lens Clear Borosilicate glassReflector ExternalStainlessSteelAISI316Lhelideckreflector(275mm)Colour rendering RA>80Lamp colour White (Colour 830)Ingress protection IP66Voltage range 200-277Vac/dc 50/60Hz +/-6%Power 85W(Re)ignition InstantAmboent temperature -40 °C to +40 °CPowerfactor/Cosⱷ >0.92
TerminationVersion1 StainlessSteel316LJunctionBoxonlefthandside,reflectoronrighthand side. Complete w/ 2 x M25 entries w/ plugs. Terminals suitable for max. 4 mm2; suitable for through wiring.
Version2 StainlessSteel316LJunctionBoxonlefthandside,reflectorontop.Com plete w/ 2 x M25 entries w/ plugs. Terminals suitable for max. 4 mm2; suitable for through wiring.
OptionsLampcolour ClearSky®
Voltage Range 100-120Vac/dc +/- 6%
Lighting
Page 80STD-SEMCO-E-LA-0001 Rev. A
DURABLEResistant to shocks and vibrations Resistant under extreme weather and working conditions
LONGEVITY State of the art LED and driver technology
LOW ENERGY CONSUMPTION Energy savings of approx. 80%
FLOODLIGHT XTL 6 has countless applications and utilizes the latest LED technology to ensure optimal task lighting in all conditions.
BACK VIEW SIDE VIEW BRACKET
INDIVIDUAL SOLUTIONS Can be custom made with brightness up to 18840L
Page 81 STD-SEMCO-E-LA-0001 Rev. A
Floodlight - XTL 6 is designed to be the work- and industrial lamp of the future.
The XTL 6 is designed with the use of advanced 3D design tools and developed with state of the art LED and driver technology, which together with a rugged housing in pickled AISI 316 stainless steel, marine grade anodized aluminium and tempered glass, ensures a long lasting product.
Equipped with high efficacy LEDs, enabling maximum light output with minimum heat generation, with an energy consumption reduction of 80%, compared with traditional halogen light sources, the luminaires enable a very short return on investment.
The XTL 6 can be implemented in all sorts of environments and industries, such as marine & off-shore -, road -, agricultural -, harbor - and building sites, to mention a few.
SOME PEOPLE ARE AFRAID OF THE DARK OUR COMPETITORS ARE AFRAID OF THE LIGHT
Page 82STD-SEMCO-E-LA-0001 Rev. A
TECHNICAL SPECIFICATIONS
Item No.: 101446Wattage: 95WVoltage: 100-240VAC, 50-60HzBeam angle: 60o /120o
Dimensions: 300 x 335 x 100 mmIP rating: IP67Temp. range: -35o to +50oCWeight: 9.25 kgWarranty: 5 years
LIGHTING SOLUTION
HIGH QUALITY
MARINE & OFFSHORE
60o 120o
Technical specifications are calculated on data available from component manufacturers. Lumen/CRI/Kelvin are calculated before optical transmission.
LIGHT SPECIFICATIONS: KELVIN(K)/CRI, LUMEN(L)70 CRI 80 CRI 90 CRI HIGH CRI
2700K NA 13395L 11165L 9792L (97)3000K NA 14000L 11580L 10465L (97)3500K NA 14370L 12000L 11620L (93)4000K NA 14515L 12420L 12430L (93)5000K 18840L 14950L 12726L* NA
* Standard models
Page 83 STD-SEMCO-E-LA-0001 Rev. A
High quality Bridgelux elements selected in co-operation with Bridgelux specialists.
BRIDGELUX LED
High quality drivers from MeanWell, a world leading power supply provider High performance and lifetime
MEAN WELL DRIVER
Marine Grade steel, specially suited for marine environments. Exceptional corrosion resistance Excellent atmospheric corrosion resistance in polluted marine atmospheres
AISI 316 STAINLESS STEEL
M20, nickel-plated brass as standard*CABLE GLAND
*Cabling and Cable Gland options can be provided as per request.
Highest quality optical elements, made in Germany Specially developed for LED lighting modules High efficiency light output
HIGH PERFORMANCE OPTICS
High quality surface treated aluminum Capable of withstanding marine environments
MARINE GRADE ALUMINUM
Page 84
Lighting
RLX FLOODLIGHT
• ATEX and IECEx approved. Zone 1, 2, 21 and 22
• Powerful light performance
• Compact and low weight
• Designed to be appreciated by the installer and
the end user
• Wide operating temperatures
• Temperature classes T6/T5/T4/T3
• Extreme lifetime
• Light efficiency up to 80% savings from conventional
• No flame path, no maintenance
• MIL-STD-461, remarkable EMC/EMI characteristics
• Crafted for demanding marine and offshore conditions
Design protected
Zone 1 and 21
Design protected
Zone 1/21
™
Zone 1/21
™
lum1nell®
Page 85
Lighting
Electrical Specifications 40 W
RLX CxZ1.2180 W 120 W 160 W
Input voltage range 100 - 277 VAC, 100 - 300 VDC
Frequency range 50 - 60 Hz
Power factor @ 230 VAC cos < 0.9
Current @ 230 VAC 0,17 A 0,35 A 0,52 A 0,7 A
Leakage current 0,5 mA RMS @ 230 VAC 50 Hz
Recommended fuse MCB16 type C for up to 10 floodlights connected in parallel
Dim control interface (10-100%) 0 - 100 kΩ, 4 - 20 mA or 0 - 10 VDC
Terminal dimensions Mains: 0,2 - 6 mm2, Grounds: 0,2 - 16 mm2, Dim and batteries: 0,08 - 2,5 mm2 – spring terminals with looping (sketch available under “Dimensions”)
Light Specifications
Initial luminous flux 6.589 11.290 15.342 19.021
Lumen per watt 165 141 128 119
100% light output Ta < 55°C Ta < 45°C
Color rendering index (CRI) > 70
5.000 K ( 3.000 K on request)
Beam angles (degrees) Spot 15°, Medium 40°, Medium 60°, Medium 60° x 40°, Wide 80° x 60°, Oval 45° x 15°, See illustration on page 6 for more information. Photometric files available on request.
Ex and Environmental
Ambient temperature (Ta) - 55°C to + 55°C
Storage temperature - 55°C to + 80°C
Markings Zone 1, 2, 21, 22
ATEX classification CE 2585 Ex II 2G II 2D
IEC classification gas Ex eb mb opis IIC T6 Gb
Ex eb mb opis IIC T4, T5** Gb
Ex eb mb opis IIC T4 Gb
Ex eb mb opis IIC T3, T4* Gb
IEC classification dust Ex tb op isIIIC T85 Db
Ex tb op is IIIC T135, T100** Db
Ex tb op isIIIC T135 Db
Ex tb op isIIIC T200, T135* Db
Classification with alterna-tive ambient temperature
*T4, T135 @Ta <40°C**T5, T100 @TA <50°C
General Spesifications
Startup time 1 second
Weight 9,7 kg (approx.)
Cable glands 2xM25 10-18mm Through Gland2xM20 Blind Cap
Other glands and blind caps on request.
IP class IP 66/67
Predicted lifetime L70 (70% light output) Ta 25°C
>320k hours >320k hours >320k hours 175k hours
Predicted lifetime L70 (70% light output) Ta 45°C
>180k hours >120k hours >100k hours 80k hours
Corrosion class C5 m ISO 9223/12944 (for offshore and maritime environments)
Color temperature1000K 3000K 5000K 7000K
2000K 4000K 6000K
Zone 1/21
™
Lighting
RLX DxZ1.21 RLX DxZ2 aka RLX D Ex nA
Electrical Specifications 80 W 160 W 240 W 160 W
Input voltage range 100 - 277 VAC, 100 - 300 VDC 100 - 277 VAC
Frequency range 50 - 60 Hz
Power factor @ 230VAC cos < 0.98 cos < 0.95
Current @ 230VAC 0,35 A 0,7 A 1,04 A 0,75 A
Leakage current 0,5 mA RMS @ 230 VAC 50 Hz <0,75 mA @ 227 VAC
Recommended fuse MCB16 type C for up to 10 floodlights connected in parallel
Dim control interface (0-100%) 0 - 100 kΩ, 4 - 20 mA or 0 - 10 VDC N/A
Terminal dimensions Mains: 0,2 - 6 mm2, Grounds: 0,2 - 16 mm2, Dim and batteries: 0,08 - 2,5 mm2 – spring terminals with looping (sketch available under “Dimensions”)
Mains and grounds: 0,08 - 2,5 mm²
Light Specifications
Initial luminous flux 13.178 22.580 30.684 21.552
Lumen per watt 165 141 128 134
100% light output Ta < 55°C
Color rendering index (CRI) > 70
3.000 K on request)5.000 K ( 5.000 K
Beam angles (degrees) Spot 15°, Medium 40°, Medium 60°, Medium 60° x 40°, Wide 80° x 60°, Oval 45° x 15°,See illustration on page 6 for more information.
Photometric files available on request.
10° spot beam - 110° wide beam
Ex and Environmental
Ambient temperature (Ta) - 55°C to + 55°C - 25°C to + 55°C
Storage temperature - 55°C to + 80°C - 25°C to + 80°C
Markings Zone 1, 2, 21, 22 Zone 2
ATEX classification CE 2585 Ex II 2G II 2D CE 0044 Ex II 3G Ex nA IIC T5 Gc
IEC classification gas Ex eb mb opis IIC T6 Gb
Ex eb mb opis IIC T5 Gb
Ex eb mb opis IIC T4 Gb
N/A
IEC classification dust Ex tb op isIIIC T85 Db
Ex tb op isIIIC T100 Db
Ex tb op isIIIC T135 Db
N/A
Classification with alterna-tive ambient temperature
N/A N/A N/A N/A
General Spesifications
Startup time 1 second
Weight 15,2 kg 10,5 kg
Cable glands 2xM25 10-18mm Through Gland2xM20 Blind Cap
Other glands and blind caps on request.
1xM20 9-16mm Through Gland
1xM20 Blind Cap
IP class IP 66/67
Predicted lifetime L70 (70% light output) Ta 25°C
>320k hours >320k hours >320k hours 160k hours
Predicted lifetime L70 (70% light output) Ta 45°C
>180k hours >120k hours >100k hours 110k hours
Corrosion class C5 m ISO 9223/12944 (for offshore and maritime environments)
Color temperature1000K 3000K 5000K 7000K
2000K 4000K 6000K
Zone 1/21
™
Zone 2
™
Page 86
Page 87
Angled to reduce cable bend
Mounting positions:RLX CxZ1.21 With two M12 bolts the pattern fits 90-220 mm holes with full +/-15° adjustments at 160 mm.
RLX DxZ1.21With two M12 bolts the pattern fits 60-362mm holes with full +/-15° adjustment at 160 mm.
Zone 1/21
Dimensions and Installation
1
9
3
4
7
2
5
10
12 13
11
Dimensionsand Mounting Zone 1/21
™
Zone 1/21
™
Zone 2
™
Front view Fig.1 Fig.2 Fig.3
Side view Fig.4 Fig.5 Fig.6
Bracket Fig.7 Fig.8 Fig.9
Fig.10 Fig.10 Fig.11Cable glands
Terminal box Fig.12 Fig.12 Fig.13
8
6
™
Zone 1/21
™
Zone 2
™
Low Voltage Directive (LVD) 014/35/EU EN 62031:2008/A1:2013/A2:2015 – LED Modules for general lighting
Photobiological safety EN 62471:2008 – Photobiological safety of lamps and lamp systems
EMC and immunity EN 55015:2013 – Radiated and conducted emissions
EN 60945:2002 – Marine Equipment. EMC Immunity, Radiated and Conducted Emissions (not on RLX DxZ2)
MIL-STD461F CE101, CE102 and RE102 - Navy Top Deck (not on RLX DxZ2)
MIL-STD461F CE101, CE102 and RE102 - Navy Mobile & Army (not on RLX DxZ2)
Explosion proof standards
RLX CxZ1.21 and RLX DxZ1.21
IEC/EN 60079-0:2012 – Equipment General Requirements
IEC/EN 60079-7:2015 – Equipment protection by increased safety “e”
IEC/EN 60079-18:2015 – Equipment protection by type of protection “m”
IEC/EN 60079-28:2015 – Protection of equipment and transmission systems using optical radiation “op is”
IEC/EN 60079-31:2014 – Equipment dust ignition protection by enclosure “t”
Explosion proof standards
RLX DxZ2
EN 60079-0:2012 – Equipment General Requirements
EN 60079-15:2010 – Equipment protection by type of protection “n”
Body / casing / chassis Seawater resistant; casted, anodized and powder coated aluminium
Glass Tempered glass
Bracket, bolts, nuts etc. Stainless steel AISI 316L (1.4404), A4
Approvals and Declarations
Materials
1
2 3
Options and Accessories
1 Pole mount bracket Ø30-Ø100
2 Protection Guard Set
3 Retrofit bracket 130, 160 to 225-260, 350-380
4 Connection Box Gel KIT (Only RLX DxZ1.21
Zone 1/21
™
Zone 1/21
™
Zone 2
™
4
Page 88
Wide 80x60
Spot 15
Medium 60x40
Medium 60
Medium 40
Oval 45x15
RLX CxZ1.21 and RLX DxZ1.21 Beam Alternatives
RLX DxZ2 Beam Alternatives
Beam group Beam codeLight projection
– diameter @ 10m distance
Color code
Spot beams Spot 15 2,6 m
Medium beams
Medium 40 7 m
Medium 60 10 m
Medium 60 x 40 10 x 7 m
Wide beams Wide 80 x 60 14 x 10,5 m
Oval beams Oval 45 x 15 8 x 2,6 m
Beam group Beam codeLight projection
– diameter @ 10m distance
Color code
Spot beams Spot 10Spot 20
2 m3 m
Medium beams
Medium 30 5,4 m
Medium 40 7 m
Medium 60 10 m
Wide beams WideWide Offset
28 m34 m
Oval beams Oval HOval V
8,2 x 2 m2 x 8,2
Spot10
Spot20
Medium30
Medium60
Medium40
OvalH -45.12
WideOffset - 120.50
Wide - 110.45
OvalV - 12.45
Zone 1/21
™
Zone 1/21
™
Zone 2
™
Page 89