Page 1 Version: V1.3 Release date: 2017-10-22 Copyright 2017 DV Vendor ID 310 / 0x0136 Bytes: 01 36 / 0x01 0x36 Device ID 841 / 0x000349 Bytes: 00 03 49 / 0x00 0x3 0x49 Vendor name ifm electronic gmbh Vendor text www.ifm.com Vendor URL http://www.ifm.com/ifmgb/web/io-link-download.htm Communication IO-Link revision V1.1 Bit rate COM2 Minimum cycle time 8.00 ms SIO mode supported Yes Features Block parameter setting Yes Data storage Yes Device version DV2500 5-segment LED tower, standard, with bracket, without buzzer DV2510 5-segment LED tower, standard, with bracket, with buzzer DV2520 5-segment LED tower, standard, without bracket, without buzzer DV2530 5-segment LED tower, standard, without bracket, with buzzer

Upload: others

Post on 23-Mar-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1

Version: V1.3 Release date: 2017-10-22

Copyright 2017 DV Vendor ID 310 / 0x0136 Bytes: 01 36 / 0x01 0x36 Device ID 841 / 0x000349 Bytes: 00 03 49 / 0x00 0x3 0x49

Vendor name ifm electronic gmbh Vendor text www.ifm.com Vendor URL http://www.ifm.com/ifmgb/web/io-link-download.htm

Communication

IO-Link revision V1.1 Bit rate COM2 Minimum cycle time 8.00 ms

SIO mode supported Yes

Features

Block parameter setting Yes Data storage Yes

Device version

DV2500 5-segment LED tower, standard, with bracket, without buzzer

DV2510 5-segment LED tower, standard, with bracket, with buzzer

DV2520 5-segment LED tower, standard, without bracket, without buzzer

DV2530 5-segment LED tower, standard, without bracket, with buzzer

Page 2

Process data Total bit length = 48 (output process data) On/Off mode

true = on

false = off

Name Description Data type Bit offset Bit length Value range Gradient Offset Unit NN BooleanT 47 1 (false) inactive

NN BooleanT 46 1 (false) inactive

NN BooleanT 45 1 (false) inactive

NN BooleanT 44 1 (false) inactive

NN BooleanT 43 1 (false) inactive

NN BooleanT 42 1 (false) inactive

NN BooleanT 41 1 (false) inactive

Buzzer Buzzer BooleanT 40 1 (false) inactive (true) active

NN UIntegerT 32 8 0

NN UIntegerT 24 8 0

NN UIntegerT 16 8 0

NN UIntegerT 8 8 0

NN BooleanT 7 1 0

NN BooleanT 6 1 0

NN BooleanT 5 1 0

Segment 5 BooleanT 4 1 (false) inactive (true) active

Segment 4 BooleanT 3 1 (false) inactive (true) active

Segment 3 BooleanT 2 1 (false) inactive (true) active

Segment 2 BooleanT 1 1 (false) inactive (true) active

Segment 1 BooleanT 0 1 (false) inactive (true) active

Page 3

Page 4

Process data Total bit length = 48 (output process data) RGB mode

Switching off

true = on

false = off

Name Description Data type Bit offset Bit length Value range Gradient Offset Unit NN BooleanT 47 1 (false) inactive

Buzzer style UIntegerT 44 3 0..7

NN BooleanT 43 1 (false) inactive

NN BooleanT 42 1 (false) inactive

NN BooleanT 41 1 (false) inactive

Buzzer Buzzer BooleanT 40 1 (false) inactive (true) active

NN BooleanT 39 1 (false) inactive

Segment 5 appearance UIntegerT 36 3 0...6

NN BooleanT 35 1 (false) inactive

Segment 5 colour UIntegerT 32 3 0..7

NN BooleanT 31 1 (false) inactive

Segment 4 appearance UIntegerT 28 3 0...6

NN BooleanT 27 1 (false) inactive

Segment 4 colour UIntegerT 24 3 0..7

NN BooleanT 23 1 (false) inactive

Segment 3 appearance UIntegerT 20 3 0...6

NN BooleanT 19 1 (false) inactive

Segment 3 colour UIntegerT 16 3 0..7

NN BooleanT 15 1 (false) inactive

Segment 2 appearance UIntegerT 12 3 0...6

NN BooleanT 11 1 (false) inactive

Segment 2 colour UIntegerT 8 3 0..7

NN BooleanT 7 1 (false) inactive

Segment 1 appearance UIntegerT 4 3 0...6

NN BooleanT 3 1 (false) inactive

Segment 1 colour UIntegerT 0 3 0..7

Page 5

Values

Value Colour Appearance Buzzer style

0 Off Continuous

lighting

No sound

1 Blue Flashing slow Rapid intermittent beep

2 Green Flashing med. Rapid Hi Lo

3 Cyan Flashing fast Sweep sound

4 Red Flashing slow Continuous beep sound with cycle ON/OFF

5 Purple Flashing med Rapid intermittent beep with cycle ON/OFF

6 Amber Flashing fast Rapid Hi Lo with cycle ON/OFF

7 White Not used Sweep sound with cycle ON/OFF

Page 6

Process data Total bit length = 48 (output process data) Analogue mode

true = on

false = off

Values

Value Analogue style Buzzer style

0 Not set (all off) No sound

1 Background: Off Indicators: White Direction: From bottom to top

Rapid intermittent beep

2 Background: Off Indicators: White Direction: From top to bottom

Rapid Hi Lo

3 Background: Off Indicators: White Direction: From bottom to top

Sweep sound

Name Description Data type Bit offset Bit length Value range Gradient Offset Unit NN BooleanT 47 1 (false) inactive

Buzzer style UIntegerT 44 3 0..7

NN BooleanT 43 1 (false) inactive

NN BooleanT 42 1 (false) inactive

NN BooleanT 41 1 (false) inactive

Buzzer Buzzer BooleanT 40 1 (false) inactive (true) active

NN UIntegerT 32 8 0

NN UIntegerT 24 8 0

NN UIntegerT 16 8 0

NN BooleanT 15 1 false

NN BooleanT 14 1 false

NN BooleanT 13 1 false

NN BooleanT 12 1 false

UIntegerT 8 4 0..9

UIntegerT 0 8 0..100 0 0 %

Page 7

4 Background: Off Indicators: White Direction: From top to bottom

Continuous beep sound with

cycle ON/OFF

5 Background: green Indicator: blue Direction: From bottom to top

Rapid intermittent beep with

cycle ON/OFF

6 Background: Red Indicator: Blue Direction: From bottom to top

Rapid Hi Lo with cycle

ON/OFF

7 Background: Yellow Indicator: Blue Direction: From bottom to top

Sweep sound with cycle

ON/OFF

8 Background: Off Indicators: White Direction: From bottom to top

Not set (all off)

9 Background: Off Indicators: White Direction: From top to bottom

Not set (all off)

10 Not set (all off) Not set (all off)

11 Not set (all off) Not set (all off)

12 Not set (all off) Not set (all off)

13 Not set (all off) Not set (all off)

14 Not set (all off) Not set (all off)

15 Not set (all off) Not set (all off)

Page 8

Variables

Name Index Subindex Data type Length Access Factory setting Value range Factor Offset Unit

rights

Standard command

2 Sub 0 UIntegerT 8 bits wo (130)

Restore the factory

setting

(240)IO-Link 1.1 system test

command 240, event 8DFE appears

(241)IO-Link 1.1 system test

command 241, event 8DFE disappears

(242)IO-Link 1.1 system test

command 242, event 8DFF appears

(243)IO-Link 1.1 system test

command 243, event 8DFF disappears

Unit locking

12 Sub 0 RecordT 16 bits rw

Data storage bitOffs 1 BooleanT 1 bit (false) (false) open (true) locked

Local user interface bitOffs 3 BooleanT 1 bit (false)

(false) open (true) locked

Name of the manufacturer

16 Sub 0 StringT 48 bytes ro ifm electronic gmbh

Manufacturer text

17 Sub 0 StringT 48 bytes ro www.ifm.com

Product name

18 Sub 0 StringT 32 bytes ro

Page 9

Variables

Name Index Subindex Data type Length Access Factory setting Value range Factor Offset Unit

rights

Product ID

19 Sub 0 StringT 16 bytes ro

Product text

20 Sub 0 StringT 64 bytes ro

Serial number

21 Sub 0 StringT 16 bytes ro

Hardware version

22 Sub 0 StringT 16 bytes ro

Firmware version

23 Sub 0 StringT 16 bytes ro

Application-specific

marking 24 Sub 0 StringT 32 bytes rw ***

Device status

36 Sub 0 intagerT 8 bytes ro (0) Device is OK (1) Maintenance required (2) Outside the specification (3) Function check (4) Fault 5 to 255 (reserved)

Detailed device status

37 Sub 0 ArrayT 21 bytes ro 00 00 00 h

Page 10

Variables

Name Index Subindex Data type Length Access Factory setting Value range Factor Offset Unit

rights

Active events Bit mask for currently active events

545 Sub 0 RecordT 4 bytes ro

Bit_31, bit 31 indicates the assigned active event

bitOffs 31 BooleanT 1 bit (0) noEv (0) noEv (1) 0x8DFF

Bit_30, bit 30 indicates the assigned active event

bitOffs 30 BooleanT 1 bit

(0) noEv (0) noEv

(1) 0x8DFE

Bit_2, bit 2 indicates the assigned active event

bitOffs 2 BooleanT 1 bit

(0) noEv (0) noEv

(1) 0x7710

Bit_1, bit 1 indicates the assigned active event

bitOffs 1 BooleanT 1 bit

(0) noEv (0) noEv

(1) 0x6320

Bit_0, bit 0 indicates the assigned active event

bitOffs 0 BooleanT 1 bit

(0) noEv (0) noEv

(1) 0x5000

Page 11

Variables

Name Index Subindex Data type Length Access Factory setting Value range Factor Offset Unit

rights

Parameter Setting error

Shows the parameter incorrectly set at the time of the download

546 Sub 0 ArrayT 10*32 bits

ro 0 (0) OK (44826624) Operating mode (786432000) On/Off segment colour (786497536) Segment appearance (786563072) Segment intensity (786628608) Buzzer intensity (35717120) BitCoded_ActiveEvents (35717121) BitCoded_ActiveEvents.Bit_0 (35717122) BitCoded_ActiveEvents.Bit_1 (35717123) BitCoded_ActiveEvents.Bit_2 (35717124) BitCoded_ActiveEvents.Bit_30 (35717125) BitCoded_ActiveEvents.Bit_31 (35782656) ParaConfigFaultCollection

Page 12

Variables

Name Index Subindex Data type Length Access Factory setting Value range Factor Offset Unit

rights

Operating mode

684 Sub 0 UIntegerT 1 byte rw 1 (0) - On/Off mode (1) - RGB mode (2) - Analogue mode

On/Off segment colour Colour of the respective segments

12000 Sub 0 UIntegerT 5 bytes rw Seg. 1 = 1 Seg. 2 = 3 Seg. 3 = 2 Seg. 4 = 7 Seg. 5 = 4

(0) - Off (1) - Red (2) - Green (3) - Amber (4) - Blue (5) - Purple (6) - Cyan (7) - White

Segment appearance Indication style

12001 Sub 0 UIntegerT 5 bytes rw Seg. 1 = 0 Seg. 2 = 0 Seg. 3 = 0 Seg. 4 = 0 Seg. 5 = 0

(0) - Continuous lighting (1) - Flashing slow (2) - Flashing med. (3) - Flashing fast (4) - Flashing slow (5) - Flashing med. (6) - Flashing fast

Segment intensity Intensity of the segments

12002 Sub 0 UIntegerT 5 bytes rw Seg. 1 = 75 Seg. 2 = 75 Seg. 3 = 75 Seg. 4 = 75 Seg. 5 = 75

0…100 (0x00 - 0x64)

0 0 %

Buzzer intensity Volume buzzer

12003 Sub 0 UIntegerT 1 byte rw 100 0…100 (0x00 - 0x64)

0 0 %

Page 13

Events

Code Name Type Description

0 d / 0x0000 h No error Notification No error

20480 d / 5000 h Hardware error in the unit Error Replace the unit

25376 d / 6320 h Parameter error Error Check the data sheet and the values.

36350 d / 8D FE h Test event 1 Warning Event appears if index 2 is set to the value 240, event disappears if index 2 is set to the value 241

36351 d / 8D FF h Test event 2 Warning Event appears if index 2 is set to the value 242, event disappears if index 2 is set to the value 243

Error types

Error code Name Description

32768 d / 80 00 h Application error in the device - Access was denied by the device. No detailed information available

no details

32785 d / 80 11 h Index not available Access to a non-existing index

32786 d / 80 12 h Subindex not available Access to a non-existing subindex

32800 d / 80 20 h Service currently not available The parameter cannot be accessed. The device does not allow access in the current mode

32803 d / 80 23 h Access denied Write access to a write protected parameter

32820 d / 80 34 h Index currently not accessible The device does not allow access in the current mode

32816 d / 80 30 h Parameter value outside the Written parameter is outside the admissible value range

permissible range

32819 d / 80 33 h Parameter length too great Written parameter length is greater than permitted

32820 d / 80 34 h Parameter length too small Written parameter length is smaller than permitted

32821 d / 80 35 h Function not available Written command is not supported by the device

32822 d / 80 36 h Function currently not available Written command is not supported by the device in the current mode

32832 d / 80 40 h Invalid parameter set Written individual parameter value conflicts with the other parameter settings

32833 d / 80 41 h Inconsistent parameter set Inconsistencies were detected at the end of the block parameter transfer. The device plausibility check failed

32898 d / 80 82 h Application not ready Access denied because the device is currently not ready