version descritpion document - inspect 3d · r3908:”in the form dev view you can not make...

23
VERSION DESCRIPTION DOCUMENT Last modification: 2014-01-24 Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.4.0.0.0 (patch 1-14) Date of print 2014/02/06 23 page(s) VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 1 of 23 Form I3D-VDD001 Release Date: 2013-06-07 General Advantages: Display Renishaw tools using graphic library Renishaw PH20 management Collision avoidance STEP CAD interface Driver Pantec Eagle Pro Romer Arm Driver RDS API Laser tracker driver Extensions: Tool builder o Ability to define components mounted on measuring head using graphic library o o Action displayed in report o Add ability set the printable status of an action o If unactive the action will not be printed in text and graphical repor o New shortcut o F7: Editor :Change action status Display/Not Display o CTRL-S : Editor :save current operation sequence o CTRL-F9: Display simulator window o For others shortcuts please check help “18.2 INCA3D shortcuts” Kreon Aquilon and Zephyr II new driver DMIS importation o Management of include files INCLUDE

Upload: others

Post on 25-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VERSION DESCRIPTION DOCUMENT

Last modification: 2014-01-24

Responsible: Stéphane PÉNEAU (Inspect 3D) Software version: V.4.0.0.0 (patch 1-14)

Date of print 2014/02/06 23 page(s)

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 1 of 23 Form I3D-VDD001

Release Date: 2013-06-07

General Advantages:

Display Renishaw tools using graphic library Renishaw PH20 management Collision avoidance STEP CAD interface Driver Pantec Eagle Pro Romer Arm Driver RDS API Laser tracker driver

Extensions:

Tool builder o Ability to define components mounted on measuring head using graphic library

o o

Action displayed in report o Add ability set the printable status of an action o If unactive the action will not be printed in text and graphical repor

o New shortcut

o F7: Editor :Change action status Display/Not Display o CTRL-S : Editor :save current operation sequence o CTRL-F9: Display simulator window o For others shortcuts please check help “18.2 INCA3D shortcuts”

Kreon Aquilon and Zephyr II new driver

DMIS importation o Management of include files INCLUDE

Page 2: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 2 of 23 Form I3D-VDD001

o Management of macros MACRO/CALL

Scanning o Ability to filter scanned point (access Yellow “+” in ops editing parameters, deviation)

o Guidance improvement

o Access to activate and deactivate, these guidance skills is especially interesting for manual CMM, Measuring arms and Laser Tracker

o

o Add target sign on next probed point in teach and execution

Page 3: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 3 of 23 Form I3D-VDD001

Management of Daimler/Audi csv file according to specifications V4.0

Management measure without trigger o A probed point without vector is generated when pressing F5 on computer keyboard o Available for inca.exe, IncaIPPServer.exe and Machine.exe

ANC40 Milling o Software management of the 5 axis with MORA ZAK

New Out of tolerance window

New Action o Cylinder constructed by circles o Plane constructed by a list of points with offset. Allows to create a plane with points

probed at different altitude

New feature for multipart execution o Ability to confirm number of loop by user

o o Ability to fill header data for all measurements

o o This feature is also compatible with barcode reader management

IGES exportation o Export Circles, Cylinders and Spheres in IGES format

Tolerances o Ability to select centered tolerance means Lower Tol = -Upper Tol. o Abilty to copy tolerance chosen in Y to all other compliant tolerance fields

o Also available in Glossary

Usable Operating Systems:

Page 4: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 4 of 23 Form I3D-VDD001

Windows™ Seven Pro (64 or 32 bits without aero);Windows™ Vista Pro (64 or 32 bits without aero), Windows™ XP Pro (32 bits),

Compatibility of the hardware device, Counter Card, Link to DCC must be checked separately with the hardware provider

INCA3D installation and License Key Installation must be performed with Windows™ administrator right.

Multiplex Configuration:

Working directories /CAD and /OperationSequence should be same shared directories on all PC’s.

Dongle driver:

Download at http://www.inspect-3d.com/english/software/download.htm - For Windows Vista, Seven, XP 1- Install first HASP HL Driver V5.22: haspusersetup.exe (V5.22) 2- Then install HASP4 Device Drivers V 5.22: hdd32.exe (HASP4 V 5.22)

Remarks

Some of the functions and improvements described in this document may not be available for your INCA3D license depending on Package and options. Contact us for further details

Documentation updates: 2012-12-04 English Help Version E.1.20 2012-12-04 German Help Version G.1.8 2012-12-04 French Help Version F.1.11

Valid Maintenance Date needed: 2012-09-15

Wish done: R4195:”New operation cylinder constructed by n circles” DONE R4231:”Possibility to define color for Cad cylinder and Cad cone.” DONE R4232:”Export Circles, Cylinders and Spheres in IGES format” DONE R4202:”Ability to send a single point to ops by mouse click instead of “shift” mouse click ” DONE R4253:”When generate a report in Text, Excel, HTML, possibility to have the trend not as a

graphic but with characters ("___+++_", "__--___")” DONE R4263:”In "Define graphic view status" window, should add key functions :

Delete Key : like delete btn. Ctrl up et Ctrl down keys : like up & down buttons. F2 : Rename (to be written in the btn hint ... not in the trt but in sources) F7 : (like in e” DONE

R4297:”Add the possibility to use Up & Down keys in the Probe driver and Machine drive selection combobox.” DONE

R4304:”Add a button in the Action parameters window to delete measuring path and probed point.” DONE

R4330:”In action parameter window the select Tabsheet highlight is not enough visible” DONE R4336:”Possibility to hide "…" button using "User simplification window".” DONE R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position

of the points (Min Max)” DONE R4063:”Display the gage point with a cross of 3 pixels size because cannot easy to see when

open an action gage point on the large cad part” DONE R4418:”New operation : Plane constructed by a list of points with offset. Allows to create a plane

with points probed at different altitude.” DONE

Fixed Bugs: R4153:”In double screen, the "Collision Detection" dialog is on the main screen and not on the

graphic screen.” FIXED R4188:”The waiting window that displays "Open ops", "Open meas", "Save ops", "Save meas",

"Save gps", is not displayed on Inca3D main window screen but always on mainscreen.” FIXED

R4190:”Main Inca3D open window does not appear screen center and not always on the screen of Inca3D (dual screen).” FIXED

R4139:”if comment without caracters nothing visible in the editor” FIXED

Page 5: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 5 of 23 Form I3D-VDD001

R4337:”Glossary: Manage default parameters for alignments” FIXED R3216:”ability to filter scanned point with Scanning probes (SP25,…)” FIXED R3233:”Ability to set numerical filter for scanned entitiies” FIXED R3685:”SP25 They reported, that the curves are still not smooth enough. And the coaxiality

should be 0 instead of 0.2.” FIXED R4344:”Romer arm thru RDS” FIXED R4307:”Create a coord syst, it is the Cad CS. Delete the coord syst. Create a new one, the option

Cad CS is not checked by default (even if no other CS in the ops). Probe Surf point. They are not displayed a the right place.” FIXED

R4342:”If I check "Export individual points" in a Cylinder I cannot select probed points in a distance point-line. To workaround, I need to use "points by reference" operations.” FIXED

R1565:”Gage point action : When we use the securiy plane, the displayed point in the graphic is to small : we do not see it.” FIXED

R4349:”If we create a large operation sequence or if the files are stored on a server with slow access. If I click on the button "Store OPS" and immediatly after on the button "New ops" then Inca3D begins to store the OPS and displays the msg "Do you want to sav” FIXED

R4223:”User windows position file is not stored in the hotline messenger file ?” FIXED R4347:”When receive data from cad to a circle some decimal are not display (ex: 10.00005) so

the iso tolerance is not calculated properly. It is also not possible to remove the decimals when re-enter manualy "10".” FIXED

R4340:”With a view locked, change shaded to wireframe with button, this option is kept even if locked ! Normally, need to keep the original mode.” FIXED

R4249:”Excel Report, each undisplayed action (F7), create an empty line in XLS” FIXED R3698:”highlighting of the label link line does not work when display NOMIL entity and ACTUAL

entity in the Graph. Parameters” FIXED R4375:”When change one reference in the editor by F2 key. Try to close automatically current

opened action because many time there is an opened action that is not modified.” FIXED R4377:”Events operations : Write the beginning of the event text in the editor.” FIXED R4390:”Activate by default "Recalculate referenced entities" & "Calculate intermediate form

deviations" in teach & learn mode” FIXED R4393:”When click on the HotLineMessenger button, the window goes behind Inca3D.” FIXED R4378:”Rectangle (twins) on geometrical part cannot extract nominal” FIXED R4396:”Add a menu in each tolerance of all measured operations to : Copy the tolerance to all other compatible tolerances of the operation. To open the selected User Tolerance File (f.i MyCustomer.tol) Reload User Tolerance Files” FIXED R4401:”Add a popup menu on the red/green target button used in keyboard entities to click points

or circles or existing elements in the graphic. F.i with this popup menu you can click in graphic a circle to use its center in a Keyboard point operation (click a s” FIXED

R4387:”using inca on a CMM with or without CAD generate sometimes unexpect movement (traslation or zoom) of the graphic” FIXED

R4405:”When the simplification file is not compatible for any reason. Display the error message like in current version but after ask the user if he wants to delete it (will avoid the need to explain the user which file to delete).” FIXED

R4406:”Optimize Load and Save of files” FIXED R4407:”When delete an action and modify the action which are using this action. Sometimes it

display "Can not find the deleted action" even if it is no more used” FIXED R4409:”Window displaying the action out of tolerance during execution is not reseted when

loading a new operation sequence. Store also in the ini file the position of the window & the status iconize or not.” FIXED

Page 6: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 6 of 23 Form I3D-VDD001

Modifications & Bug fixes (patch V4001 – 2012-11-15):

Wish done: R4439:”Add a menu "Show / Hide virtual machine window" in the counter window menu.” DONE

Fixed Bugs: R4433:”Be able to deactivate ChangeTool() event from I++ server” FIXED R4361:”Download "Visual C++ 2005 Redistributable Package" in error msg box works but

installation does not start” FIXED R4437:”In the window "editing options", in the tab sheet "action validation" it is written "search

distance" instead of "Validation distance"” FIXED R4328:”Circle measured: when creating circle measured with nominal constructed (f.i intersection

cylinder - plane) you can choose Radius/diameter display but when reopen it is no more displayed” FIXED

R4439:”Add a menu "Show / Hide virtual machine window" in the counter window menu.” FIXED R4440:”Distance constructed along a bow is not always properly calculated” FIXED R4442:”Action cloud of point. Scan check cannot be unchecked with Kreon driver” FIXED R4463:”Debug with limit date is always deactivated each time we start Inca3D” FIXED R4464:”When dock the window "Selected element properties" in the bottom part of the editor : the

caption is not correctly displayed.” FIXED R4466:”The stop / play buttons that are at the bottom of the tool bar are not large enough to be

seen and be easily clicked.” FIXED R4467:”Revamp the "Out of tolerance actions" window that popup during operation sequence

execution” FIXED R4446:”Execute each time of header entity does not work in v4000 (maybe since new function

Multi OPS with BarCode).” FIXED R4458:”If switch in Entity tool bar in OnLine / OffLine, Inca3D still receives points from machine,

erro messages if manipulate the head and the probe….” FIXED R4461:”When activate a tool in UCC Server, It is added in Inca3D. In case of special NoTool, it is

also added in Inca3D Ops but normally cannot be managed by Inca3D. After if try to make a DCC movement, error.” FIXED

Modifications & Bug fixes (patch V4002 – 2013-01-09):

CAD treeview improvement: Ability to see o Color o Status Measurable (caliper icon) o Status Visible /Non Visible (black or grey text) o Keep if sorted by layer or kind entity, highlighted status

when reopen the window

Inca3D debug window o Ability open debug window from icon in menu bar

Extraction of nominal from CAD o Ability to extract entities Cylinder, Cone (including limits) from CAD surface by clicking

one point on the surface

Page 7: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 7 of 23 Form I3D-VDD001

Global modifiaction of “machine parameter”

o New actions

o Construction Circle intersection Cylinder-Cone intersection Cylinder-Sphere intersection Cone-Cone intersection Cone-Sphere

o Sphere tangent ot a cone with a given radius

For Laser Tracker and measuring arms: o Ability to create circle in 1 point by entering reflector or

arm ball in a circular hole.

Machine driver o SB controller controller TCP/IP communication available o Pantec controller TCP/IP communication available, including PH10 and handterminal

connexion.

Glossary: ability to enter a global tolerance value when creating a new glossary, pop up window

Wish done:

R4473:”Remove in Graphical paramters the color and visibility for Face, use Surface for all” DONE

R4477:”When you scroll up/down the ops or dmis editor with the mouse wheel, the display is horizontally srcolled if there is an horizontal scoll bar. It should never scroll horizontally.” DONE

R4500:”Abilty to scan cylinder by spiral with SP25” DONE R4511:”In tool selection window, increase column size for reference of the I++ tool” DONE R4512:”Kreon driver using Inca3D plug-in done by Kreon instead of Kreon tool kit” DONE R4499:”Ask the default tolerance values when create a new glossary” DONE R4529:”Be able to sent part temperature to the I++ Server” DONE

Fixed Bugs: R4398:”Inca3D + CMMOS + Standard probe: Inca3D only display the ball not the complete tool”

FIXED R4399:”Driver Leitz: Handbox event missing (OK, Capture gage point)” FIXED R4424:”Driver Pantec.Eagle : Click on plane with apply and probe, probe the first point then no

more point can be probed, probe status is not ON after the 1st probe point.” FIXED R4425:”Manual machine whith indexed head: When start multi probe calibration, can not delete

last point probed, hold point reception, ….” FIXED R4426:”Hole detection: If probing depth for 2D action is positiv (probing done up to the projection

plane), hole detection generate collision. Move not done in the right way.” FIXED R4392:”When I select in the configuration module MH20i and I try to display the probe grid there

is a crash and I must close Inca3D” FIXED R4397:”When a surface point has been executed (Offline mode) in the opposite direction, it is not

possible to reverse it even if set a new vector in the measuring path wizard” FIXED R4402:”When calculate a section, curves are not concatenated. Get only the first one.” Gelement

v317.FIXED

Page 8: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 8 of 23 Form I3D-VDD001

R4485:”SB CNC driver: Switch off air system doesnot work” FIXED R4506:”When execute an ops with machine param Approach=2, probe point, machine param

Approach=20 probe point…., second probe point is probed with approach=2 instead of approach=20” FIXED

R4472:”When select several probe in tools manager grid to do virtual calibration, Dialog is not

displayed when modification is ON” FIXED R4478:”SP25: Cannot check Scan in Action param if action is different than cloud or curve”

FIXED R4479:”SP25 + I++: Cannot execute action scanned” FIXED R4480:”SP25 + Virtual CMM: Be able to perform scanning as for I++” FIXED R4482:”Tube operation: Not possible to add several cylinders.” FIXED R4483:”Windows Vista / 7 : Many time text of tree nodes in the treeview is displayed like if it is

bold.” FIXED R4470:”Cancel the report preview before the end of creation of all pages. Graphical view is

locked. Have to restart Inca” FIXED R4451:”In report format editor, when define a user string, if no text or only space characters, the

text has been replaced by <$85130$> in the componant added. Not nice, need to but a . In white color !” FIXED

R4062:”Add checkbox to remove head rotation confirmation during automatic calibration” FIXED R4395:”Circle by one point for Laser Tracker” FIXED R4493:”Calculate nominal data for probed points failed for circles when points are probeb above

the projection plane” FIXED R4415:”Action scan with pantec eagle Controller: Retract distance is not affected by the

parameters calculated by the scan dll” FIXED R4438:”Construction sphere tangent to a cone with a given radius” FIXED R4441:”Construction Circle (- intersection Cylindre-Cone - intersection Cylinder-Sphere -

intersection Cone-Cone - intersection Cone-Sphere)” FIXED R4497:”When I select a circle, a point vector or any geometric entity in the graphic and I send it to

the operation sequence if there is no opened operation Inca3D refuses to use it. F.i before sending a circle I need to open a circle.” FIXED

R4266:”If more than one "load cad file" in an OPS then validate measure does not work (? before each surface point that not corresponds to current load cad file").” FIXED

R4492:”Horizontal scrollbar is missing in the measuring path editor when we are working with a validation point” FIXED

R4489:”Construct a cone in the graphic and try to send it to a Cone Kb, nothing” FIXED R4494:”After setting Load CAD action in XX deactivate, if you print a graphic report CAD appears

again. That implies also later that collision detection is not working anymore without warning message” FIXED

R4502:”Change some default graphical parameters: grid, colors…” FIXED R4508:”Comment operation. Display the reference of the action and be able to change it like any

operation (except header). Make sure the reference cannot be confused with the comment.” FIXED

R4420:”Scanned cylinder : copy paste takes very long time (50sec for 561 action)” FIXED R4510:”Sometimes the color of the probe displayed is not correct (gold color instead of real color

of the probe).” FIXED R4496:”PH20 not properly displayed . Have to invert the Z axis in configuration in order to have

the right display in graphic but then always collision detection !” FIXED R4513:”With I++ and PH10 and SP25, the temporary probe is not displayed.” FIXED R4514:”SB CNC driver : Allow TCP/IP connection with controller” FIXED R4515:”Pantec Eagle driver : Allow TCP/IP connection with controller. In this case,

communication with PH10 controller and handbox HT400 can also be done with TCP/IP connection” FIXED

R4516:”No more confirmation message when delete or modify a change probe action saying that the next actions will be executed with a new probe orientation (since V3500)” FIXED

R4519:”The MS Windows UserName login is not added in the "Inspector Name" and "Operator Name" combo box in the header operation except if a Name has already been stored in the list by the user (using green +).” FIXED

Page 9: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 9 of 23 Form I3D-VDD001

Modifications & Bug fixes (patch V4003 – 2013-02-18):

New machine sounds: o Start and Stop scanning for Measuring Arms and Laser Trackers o Validation Point sound o Sound on not valid point

FARO Arm USB Driver o Version 5.6.5.3 for 32 and 64 bits o Display current probe radius in counter

Measuring Arms and Laser Tracker o New Leapfrog management o Access in Counter popup menu

Documentation updates: 2012-02-18 English Help Version E.1.21 2012-02-18 German Help Version G.1.9 2012-02-18 French Help Version F.1.12

Fixed Bugs: R4538:”Scanning with SP25. Filtering is not done at the end of the execution of the action. Have

to reopen the action and revalidate to perform the calculation” FIXED R4537:”The out of tolerance window that is shown during the execution displays in black the out

of tolerance radius.” FIXED R4501:”Allow user to enter part temperature in Inca3D for I++ Server. In this case CAA is not

done by Inca3D but by I++ Server. Set Temperature of Part not working via I++” FIXED

Page 10: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 10 of 23 Form I3D-VDD001

R4533:”When switch to FARO driver, we switch automaticaly to Faro probe but internaly we keep the previous probe driver selected and when the option is not available we display an error message. Ex "PH option not available" (only displayed when reopen the config” FIXED

R4545:”When print a report with statistic graph display (mode with lines), the rectangle used to display value are very small (not adapted to the printer resolution)” FIXED

R4535:”I open in the graphic the Selected element properties window. If I move the mouse on the popup horizontal button to choose view orientation X+ X- Y+ Y- … the buttons go below the Selected element properties window.” FIXED

R4534:”Define graphic view status window. If a create a new view, press F2 to change its name and press Del key to delete a character it deletes the view and not only the character.” FIXED

R1648:”Missing display of the normal vector when contruct a Roundslot,Rectangle,… usefull for checking the orientation before adding in Cad file” FIXED

R4547:”Comment displayed in the editor for the event action is not properly recalculated when make a global calculation of the operation sequence” FIXED

R4549:”Some Report view are empty or offset and stretched after installing new driver for printer.” The paper size was set to A4 Small. FIXED

R4531:”SB Elektronik machine driver: With TP200 when receiving a invalid probe point regarding damp value, display sound to inform the user” FIXED

R4556:”Reduce minimum distance between the 2 points used to define sphere holder direction from 40mm to 10mm” FIXED

R4517:”Plane by points and offsets. If the points have no vector no error message is displayed and the offset is done in Z direction.” FIXED

R4557:”Check Sphere diameter when start sphere calibration, not after several dialogs” FIXED R4558:”When start automatic calibration of sphere using standard probe, error message is

displayed instead of automatic calibration dialog when parameters have never been set once” FIXED

R4385:”for laser tracker, if measure with wrong SMR ability to make a global modification to change SMR Radius 1"5 to 0"5” FIXED

R4412:”Add in the ASCII file import to create an operation sequence the possibility to sort the actions like it is done is csv importation” FIXED

R4564:”The measure window (click on small button right to measure number) closes itself if the mouse moves outside. It should not.” FIXED

R4559:”F2 (Rename) in the editor tree view does not work for comment operations” FIXED R4567:”ZAK+Star probe: When call a ZAK tool with tip 2,3,4,5, tool offset if not re-calculated

Since V4000” FIXED R4568:”MAS Position calibration: Recalculate the direction of the MAS Position normal vector

independently from order of sphere 2 and sphere 3 of the MAS Position. If you probe Sphere #1, #2 and #3 or Sphere #1, #3 and #2 you will get the good norml direction” FIXED

R4569:”MAS Position calibration: Display result of calibration of the MAS Position after the 3 spheres in the dialog” FIXED

R4570:”MAS Position calibration: After probed the 3 spheres, calculation of the calibration is not called automatically” FIXED

R4572:”Circle probed in one point is not working with the vector creation through a validation point” FIXED

R4575:”Driver Pantec.Eagle: Add access to Positionning acceleration and touch acceleration” FIXED

R4576:”When deactivate current probe, remove also the tool display in graphic” FIXED R4581:”API Tracker driver: Be able to used SMR with another tool diameter. Usefull when used

SMR extension to probe 2D action” FIXED R4582:”API Tracker driver: When used IProbe, be able to probe point using IProbe tip direction”

FIXED R4583:”API Tracker driver: Select T3 or Omnitrack in configuration. When cmoe back to

configuration Radian is always selected” FIXED R4584:”API Tracker driver: When start driver, API driver always display a message that omnitrack

is not valid regarding current hardware” FIXED R4585:”API Tracker driver: When used IProbe, Probed Point vector is always set with current

Iprobe tip direction” FIXED R4587:”Make new operation sequence without CAD file, then click on Geometric construction in

graphic, Inca3D closed or display exception” FIXED

Page 11: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 11 of 23 Form I3D-VDD001

R4588:”Pantec.Cmm driver: during change tool sequence, when move from unload position to position to load probe is not deactivated. This generate an error message and stop the sequence.” FIXED

R4590:”When start Inca3D display only the current tool head until the 1st change tool” FIXED R4571:”Ability to calculate length of probed curve and insert result in the report.” FIXED R4573:”When use average plane for circle and validation point, the normal vector orientation is

not calculated with the validation point” FIXED R4593:” Some fields (like probe name in the counter window) are not displayed correctly in

Russian language.” FIXED R4594:” SCR200 : Head movement in Z is going above the rack” FIXED

Modifications & Bug fixes (patch V4004 – 2013-02-18):

Renishaw UCC Server o check if tool is qualified (RWIsToolQualified()) when activate or call a probe

Action Validation Parameter o Ability to save configuration of “Action Validation Parameter” in a file

o o this file can be recalled in a script action o Can also be attached to a specific probe when using laser tracker

o Multi machine management Ability to configure several machine in Inca3D configuration

Page 12: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 12 of 23 Form I3D-VDD001

o Excel Report

Ability to export each measure in a new tab sheet when « exportfilename.xls » already exists

o Export filename Ability to change export filename and export directory according to several

keywords

Available keywords are displayes in green « + »

In the following example,

Page 13: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 13 of 23 Form I3D-VDD001

Export file will be create in folder « \\Out of tol » or « \In tolerance » according to result of the measure 1 and the filename will be \Opsname0001.txt

Fixed Bugs: R4597:”Probe a plane then check scan, approach gage point done before the scanning is not well

calcuated in 0,0,7.5 instead of near the plane” FIXED R4599:”Scanning with SP25. Filtering is not done at the end of the execution of the action. Have

to reopen the action and revalidate to perform the calculation” FIXED R4600:”Tolerance tabsheet : When "by centered value" is selected, opening the combo changes

the value to "By value". If "IsoTol" is selected, it is replaced by "by centered value".” FIXED

R4609:”Some stylus extensions have not the right length when displayed in graphic.” FIXED R4612:”If the alignment corresponding to the Cad alignment is deactivated (F6) the measure file

becomes unreadable !!!” FIXED R4614:”I++ driver / Pantec Eagle driver: Parameters imported from Inca.ini to be saved in

Machine.cfg are not saved automatically when start Config.exe, Inca.exe or machine.exe.. Means that on next start data set are lost” FIXED

R4613:”Importation of "GP090801.igs" seems OK but cliking one point generate "external exception C015000F” FIXED

R4615:”File PRO-E "0730530.prt" generate UNKNOWN ERROR in V4003” FIXED R4617:”Calculation of stat (CP CPk) is wrong in one-sided tolerance case” (R4066) FIXED R4607:”When tool file is not compatible with head, Inca create a "default tool" empty, if you save it

erase any existing "default tool"”FIXED R4621:”Very particular case when scan and first scanned points sent by server are in a string

equal to 8193 bytes. Data are lost by Inca3D” FIXED R4622:”API Tracker in simulation mode (virtual CMM): Do "DCC move" as when connected to API

Tracker device (Search for target function). Allow to change speed used to simulate the "DCC move"” Only used to be more realistic… FIXED

R4623:”In taskbar, Debug windows Icon and VirtualCMM Icon are sometimes displayed several times” FIXED

R4624:”Star probe display with ZAK is not working” FIXED R4627:”In toolbuilder unable to define star orientation when used a ZAK. An error message is

displayed” FIXED R4628:”ZAK + Star probe: Tip selected in change probe action is not highlighted in graphic view”

FIXED R4629:”In change probe action cannot select a tip when use star probe + RTP20 or TESASTAR”

FIXED R4631:”Driver ND780/ND960: If time between contact and retract point is to small we wait 400ms

to be sure that beep of touch point and beep of the retract point are played” FIXED R4632:”Driver ND780/ND960: If one axis character is missing when receive data, command to

ask the current XYZ is not sent any more” FIXED R4633:”Driver ND780/ND960: Last manual retract distance is not restored when start the driver.”

FIXED R4634:”Pantec Eagle driver: If generate error Next DCC move out of limits, then I get Error

Unknow Command 33” FIXED R4635:”SB CNC driver: When probing a circle where diameter is less than current approach

and/or retract, new approach/retract calculated by Inca3D are not take into account” FIXED

R4638:”API Tracker driver: With I Probe probe vector is inverted” FIXED R4640:”Statistic label : more you add measure more the area of the graphic label stat is reduce”

FIXED R4658:”When switch to Virtual CMM (counter in blue), A&B angle of the tool are not applied in

graphic display” FIXED R4659:”No probed point received in the leap frog window with API tracker (F2 is not managed by

all Inca3D windows).” FIXED R4660:”Inside the measuring path, when call a new probe position, the tip combobox refuses to

open. Need to use Up and Down arrow keys to select the tip.” FIXED R4620:”Switch V3 to V4 : when creating ZIP file to be able to restore save only necessary files

from /machine and / tool files, nothing else.” FIXED

Page 14: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 14 of 23 Form I3D-VDD001

R4661:”Template file "Inca Part Nominal Ascii Data Example.asc" is still working with the old inca part.” FIXED

R4678:”Export the graphical view in jpeg, png, gif, emf, wmf does not work” FIXED R4679:”Inca3D freeze at startup when MultiFilesConversion is already running.” FIXED R4681:”Some surface points are not reprobed normal to the surface when create a new

measure” FIXED R4682:”If workpiece error is too high, Diameter of the end sphere for ScanInPlaneAndIsSphere is

too small and scanning may never stop” We add 1mm to the diameter. Added value can be set in Inca.ini FIXED

R4683:”Action scan 2D: if end is sphere and end closed scan selected we send N=2 instead of N=1 in command ScanInPlaneEndIsSphere(). Scan is performed 2 times” FIXED

R4685:”Edge point measured with nominal Kb may not be properly calculated when probed in 4 points” FIXED

R4686:”Excel report : Add the possibility to write the report results in an existing report excel file. If "Add a tab sheet by measure" is checked : a report excel file can contain different measures in different tab sheets.” FIXED

Modifications & Bug fixes (patch V4005 – 2013-04-11):

Wish done: R4687:”%MEAS% key word does not contain a # like old versions.” DONE Add a field in Inca.ini

if a user needs a %MEAS% without #. R4692:”Sb CNC Driver + ZAK + MAS: Set by default in Inca.ini outputs used to handle

Head+MAS for lock/unlock” For Service technicians only DONE – FIXED

Fixed Bugs: R4611:”On very large screen the action ali multiplex is very large and its size cannot be

decreased.” FIXED R4668:”Delete measuring path button in action parameter window should be displayed after the

measuring path wizard calculation. Ex : new action --> click the nominal in graphical view --> automatic calculation of the measuring path -> button is not displayed” FIXED

R4688:”If I display Inca3D using window position #15 (dual screen) and I iconize it, when I restore it the counter is displayed over the graphic.” FIXED

R4689:”If I select "Window Classic" display then the editor V and +/- marks are partially hidden.” FIXED

R4671:”When import new probes from I++ (right ckick in the counter). They are not by default set in the right group of tools” FIXED

R4647:”IGES file cannot be translated "6R4 809 588 CF ASSY.igs" "6R4 809 587 CF ASSY.igs"” FIXED

R4648:”3100-0450 DEMI BOITIER.STEP - cant be translated” FIXED R4616:”"CAD file color : sometime color do not correspond to native format color” FIXED R4521:”Exception during conversion of Step file 4474_351_167_des001.stp” FIXED R4520:”AB39-2101605 CHECKING FIXTURE with mod surfaces.igs cannot be converted” FIXED R4505:”1125074 Messen.igs cannot be converted” FIXED R4374:”Cannot convert Catia file 10104 DP Assy RAP Rr Dr LR RH Base.CATPart” FIXED R4191:”Import STEP v72, missing surface” FIXED R1967:”Kraftsensor Jaguar.igs display is not good” FIXED R2207:”CATIA V4 conversion failed on face conversion” FIXED R2209:”TOTAL_FCF_ON THE TOOL.igs bad display” FIXED R4691:”No more possible to scan a sphere : Machine moves to the sphere measuring first circle

than is moving strange the machine to the second circle but is scanning and the third circle is also scanning but after scan sequence machine moves down and made a collision” FIXED

R4416:”Iges file cannot be imported properly MF-B29TPS-02.igs” FIXED R3924:”Cannot convert the iges file.” FIXED R4690:”Report Header no more displayed in V4004” FIXED

Page 15: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 15 of 23 Form I3D-VDD001

Modifications & Bug fixes (patch V4006 – 2013-05-07):

SP25 management with Pantec Eagle-Pro

CAD importation o Abilty to import Solidworks CAD files o Ability to import Parasolid CAD files

o check if tool is qualified (RWIsToolQualified()) when activate or call a probe

Pantec Eagle Pro o Switch TCP-IP to COM communication display message to apply choice to PH10 and to

Handbox

o

Wish done: R4695:”Arm & tracker driver: Add the possibility to perform probing with retract distance” DONE R4699:”API Tracker driver: If cannot load the driver, add in error message to verify driver

installation” DONE R4707:”Possibility to export report in VDA First Inspection report format (Excel file).” DONE R4728:”Be able to send Part temperature and/or Part coefficient and/or Machine temperature to

I++ Server” DONE

Fixed Bugs: R4693:”Pantec Eagle: when switch to virtual mode, execution does not work” FIXED R4694:”When load a tool file during operation sequence execution, current tool is not any more

display correctly” Happen for tools assimilable to MIH or Standard FIXED R4697:”Pantec Eagle driver: If position 0.0,0.0,0.0 is not inside software limits when perform a

single DCC move we get from Eagle driver a error message that movement is outside software limits.” Bug is in Eagle driver, will be solved in next release of the driver. FIXED

R4700:”As for API tracker, display current Romer RDS tool name coming from driver instead of "Romer RDS probe"” FIXED

R4698:”Cannot acces to statistic parameters in the Report window” Patch 4004a FIXED R4709:”UCCServer: Send part extension coefficient to the server” DONE – FIXED R4711:”When load with Inca3D V400x or upper an operation sequence from Inca3D version less

than V1600, some action are unreadable.” FIXED R4715:”Action change probe failed when used cylinder of the stylus as cylindrical probe”FIXED R4701:”When CAA reverse compensation is not always applied” FIXED R4720:”Pantec Eagle: During operation sequence execution, sometimes retract distance is not

applied. It may generate collision.” FIXED R4726:”Excel customizable: when Excel is already running, when generate the output file, Excel

displays a confimation window to erase the existing file” FIXED R4724:”Excel not customizable: if excel is already open excel crash” FIXED R4727:”Operation sequence created from DMIS importation. Multiple solution are always selected

from the nominal value. Should be done only the first time to enable the user to modify it” FIXED

Page 16: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 16 of 23 Form I3D-VDD001

R4717:”Uccserver :SCAN 2D does not work in execution mode if gage point after. (example : GPt, Scan2D, GPt, Scan2D) generates an error after the First Scan 2D” FIXED

R4703:”UCCServer when creating a new probe orientation in UCCServer, it is available in toolmanger in "Default". It should be put in the right tool definition”FIXED

R4460:”Delete some tools and componants in UCC Server, in Inca3D when display the call probe window, we still have the deleted tools proposed. I try to reimport the I++ tools, same results. I close UCC Server, reload Inca3D, same…” User must reload file manually, no information forward by UCCServer FIXED

R4729:”UCCServer : Be able to define and used tools with star probe with Tip 1 not defined” FIXED

R4730:”In virtual CMM when make a preset and virtual CMM is in PCS, result of the preset is wrong.” FIXED

R4722:”Pantec eagle : RPM parameter for spindle are displayed in config even if no option Mill” FIXED

R4719:”Multi part execution: when overwriting meas the measure is not reset before starting execution” FIXED

R4598:”I put in comment the operation "JUMP" but when I execute the operation sequence the jump is executed nevertheless” FIXED

R4637:”Global modification : Default tolerance values are 0.150 even if glossary loaded contains 0.020” FIXED

R4746:”Iges files cannot be converted MP-6C11-010xxx.igs” FIXED R4747:”Cannot translate the Catia files "negativ transate.CATPart"FIXED R4766:”Calculation of the path wizard for cone can generate wrong probing "FIXED

Modifications & Bug fixes (patch V4007 – 2013-06-24):

Fixed Bugs: R4754:”For some head, second direction cannot be set. Bitmap is displayed but combobox is not

visible” FIXED R4755:”SP80H: Bitmap displayed for head configuration need 90° rotation” FIXED R4756:”Without option "path wizard" it is not possible to create entities in the graphic with the

green target and receive them in the nominal of cones,circles” FIXED R4757:”Tool offset send to the CAA is not exactly the same compare to V350x.” FIXED R4771:”Change the default size of the out of tolerance list window to ensure X Y Z values are

visibles.” FIXED R4780:”ANC40: When computer switch to standby mode and comm port are deactivated in

standby mode, user cannot exit from this mode. Communication with controller is crashed and does not allow to continue Inca3D session.” FIXED

R3886:”Missing surfaces in PROE Files (195p102050.prt;580p102050.prt)” FIXED R4783:”In the "Windows" menu, the last 2 window positions used are not re-translated if the

language is changed in the configuration module.” FIXED R4784:”Cannot convert the file: - qian men kuang.igs” FIXED R4748:”Cannot translate the iges and Catia files: 51001D54516153000.igs

51001D54516153000_AllCATPart.CATPart” FIXED R4789:”Cannot convert the file Caia v4 file in v3507: PT81301A00.model”

Modifications & Bug fixes (patch V4008 – 2013-07-08):

Result display during execution o Ability to stop automatic display of the result during execution,

allowing to check result of entities already probed o Activation and deactivation by buttons in execution toolbar

Chinese Help C1.0

Milling ZAK6 integration

Page 17: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 17 of 23 Form I3D-VDD001

USB temperature sensor integration

Action parameter windows o Ability to split parameters and result o Result can be docked near the action parameters

Wish done: R4800:”Like form deviation results window, grid text results and charts result windows must be

dockable window.” DONE R4801:”For large screens, add the possibility to dock result windows on the top, bottom and right

side of the action parameters window.” DONE – FIXED

Fixed Bugs: R4796:”When import tools from V350xx with star probe, star probe tips orientation is not

imported” FIXED R4797:”PH+Star probe: When open tool selection dialog with the grid, all tools are display not

calibrated” FIXED R4799:”Tool conversion from Inca3D V3 to V4 : the generic head and generic fixed head

information image is not displayed when conversion is done at Inca3D launch. If done at Configuration module launch information image is displayed.” FIXED

R4802:”Sometime the form deviation window desappears” FIXED

Page 18: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 18 of 23 Form I3D-VDD001

R4803:”The search text window of ops editor is too large to be always docked and does not work the first time when docked. I must click one time in the editor othewise text is never found.” FIXED

R4804:”Tool builder : Change the image of the button used to configure star probes : Replace the pen by a star probe.” FIXED

R4806:”In High Level mode if I delete all operations of the measured operations treeview then an error message (Internal error 1.1134) is displayed. If I do not delete all operations there is no problem.” FIXED

R4807:”ZAK6 driver (New milling head): Integrate last modification from AEH” FIXED R4808:”Problem during execution when project point on surface.” Problem in calculation of Curve

polygon fixed in patch v4005c FIXED R4809:”Restore the possibility to set in Inca.ini the machine extension coefficient (possibility was

removed in V4000)” FIXED R4810:”New I3D temperature sensor” FIXED R4812:”When machine orientation are not in same CS before the duplex alignment, a duplex

collision can be displayed after a change probe even there is no collision.” FIXED R4815:”Cannot convert the file Catia v4 file in v3507: - RA1M216130111.model” FIXED R4750:”With symmetrical tolerance ("By centered value"), the lower tolerance value is not

updated regarding the upper tolerance value.” FIXED

Modifications & Bug fixes (patch V4009 – 2013-07-26):

Fixed Bugs: R4816:”Collision detection during a call probe displays the msg "Cannot get probe geometrical

definition".” FIXED R4838:”In some dialogs like "Tool selection", the shortcuts Ctrl + B (Global bestfit or bestfit on

selected action), Ctrl + N (Reverse vector), Ctrl + E (Reverse edge vector) and Ctrl + Q (Set as view center selected action) do not work.” FIXED

R4839:”Change the yellow receivers shortcuts, Skip to next receiver "!" to "J" (was not working) Show current receiver "R" to "K" (because conflict with Reverse normal shortcut)” FIXED

R4823:”Inca part create symmetrical + origin : miss some surface” FIXED R4845:”when creating report through shortcut "ReportModel1Parameter.orp", title of the preview

is not initialize with Ops#nnnn only with ##nnnn, through regular report parameter it works” FIXED

R4847:”Pdf output without ops name” FIXED R4829:”cannot click edge point on inner border "MP-7C19-010104-B55" on surf 48980” FIXED R4813:”One missing surface from STEP file: 155111000001Rev08.STEP” FIXED R4820:”STEP part cannot click on top surface” FIXED R4851:”Milling tool cone: If cone height is L in the builder, diameter displayed in tools manager is

(L * 2)” FIXED R4848:”3115-10.igs unknown error, and "access violation at adress 015CF78C write of adress

000001"” FIXED R4863:”when you measure a element and than you would like to apply it after probing by pressing

on the keyboard the return/enter button Inca does not react and apply the element (by teach and measure)” UNIPPS Nr: 4400 FIXED

R4831:”Activate virtual CMM in counter : when probing entities with V. CMM and pathwizard, error should be NULL and we have deviation corresponding to CAA correction (0.4 mm in customer case)” FIXED

R4866:”In MCR20/SCR200 calibration dialog, text number (2) is not visible in german.” FIXED R4714:”When you switch in the counter and you press the preset then you see in the counter

shortly X0:Y0:Z0 ( 1second ) but after the counter is jumping back to the old Position” FIXED

R4873:”In MeasPath editor, when change meas path of a probed point then click on apply, modification are not save (Old value are always restored)” FIXED

R4837:”PH10MQ. In call probe action, I select "select tool by vector" (I0 J0 K1) and Inca3D creates a probe not possible A180.0 B0.0” FIXED

Page 19: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 19 of 23 Form I3D-VDD001

Modifications & Bug fixes (patch V400.10 – 2013-09-06):

Pantec Eagle controller o Management of Rotary table

Out of limit message : o When next DCC move is out of the limits an error message is displayed including target

point and CMM software limits (available for Anc40/39, SB controller, Pantec Eagle)

Access to both Netviewer and Teamviewer remote assistance program in menu window in Inca3D (internet page is also directly accessible http://www.inspect-3d.com/help )

Wishes Done: R4889:”Pantec Eagle: Management of the rotary table” DONE R4887:”SB CNC + ZAK:

Be able to choose order of the Home sequence (1st Head then XYZ or 1st XYZ then Head) Be able to home A&B in the same time or 1st A then B or 1st B then A ” DONE

R4912:”I++ DME machine driver selected, Send temperature data to I++DME Server checked: If automatic temperature update is checked, the buttons allow sending data to the I++DME server are not available.” DONE

R4654:”Out of tolerance window : Possibility to recreate the list and delete a row.” Done in the popup menu. DONE

R4855:”Calculate dynamicaly the equator offset for the star probe calibration to avoid collision regarding sphere diam. & tip length. (or simply display a warning if we detect that it will produce a collision).” DONE

R4868:”Abillty to delete a Measure in the measure windows by SHIFT+DEL without prompting YES/NO question” DONE

R4917:”Star probe with standard probe (PH1, Knuckel, …)” UNI PPS Nr. 4339 DONE

Fixed Bugs:

R4885:”Pantec Eagle + milling tools: Sometimes when stop the milling spindle still turning” FIXED R4886:”Milling + Pantec Eagle Pro: When used ethernet connection to communicate with Pantec

Eagle Pro milling command sent to the controller crashed the controller or the communication” FIXED

R4887:”SB CNC + ZAK: Be able to choose order of the Home sequence (1st Head then XYZ or 1st XYZ then Head) Be able to home A&B in the same time or 1st A then B or 1st B then A ” FIXED R4892:”In milling action parameter, to avoid confusion, hide offset parameter instead of disable

them when not used.” FIXED R4862:”when you measure a Sphere manually and you type a value of Form deviation which is

allow … When you get worst results software doesn’t display a error…” UNIPPS Nr: 4399 FIXED

R4897:”In the report file name, In V4 version by default there is a blank between OPS name and measure number and in V3 there was no blank.” FIXED

R4898:”Drag and drop in a action Plane by points of points selected in the graphic in cloud of points does not work. The complete cloud of points is always taken,” FIXED

R4899:”When a combobox or listbox contains more than 65 535 elements, the display becomes wrong if you use the scroll bar to move down.” FIXED

R4900:”Actions by Points: improve the display speed with a large number of points” FIXED R4798:”Missing parameter in measured circle when nominal keyboard and actual constructed by

points, the calculation method is not displayed” UPPS NR : 4285 FIXED R4901:”When I open or active cloud or scan operations, the result windows display the results

values but they have wrong caption "No result" instead of "<Result Cloud XX>"” FIXED R4902:”In the actual tabsheet, when I change the kind of the actual of a measured operation then

active tabsheet always switch to nominal tabsheet and I need to click again on actual tabsheet to reactivate it.” FIXED

R4792:”We have some problems with QS-Stat output. Inca doesn´t take a measured surface point in statistics and qs-stat output when used in 3D. It is only possible XYZ, not 3D vector.” FIXED Available fo all statistic output

R4905:”It is possible to deactivate and hide results of selected operations in execution mode using F6 and F7 keys. Should not be allowed.” FIXED

Page 20: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 20 of 23 Form I3D-VDD001

R4824:”Plane : when export individual points then plane is no more reducible to a plane” Ref #4525 FIXED

R4883:” In multi user mode: - if no access to teach and measure mode : icon is losked but user can activate the mode through menu - In report window: access to label editor is available even if it is normally locked for the user - ability to lock .zot editor En mode Multi User, simple user: - si pas accès mode appentissage, on peut aller dans menu Gamme - Option d'appentissage - dans fenetre du rapport, on peut accéder à editeur de label, editeur de rapport meme si bloqué - pouvoir bloquer accès Zot editeur,” FIXED

R4574:”Line KB. Il I select mode by 2 points and I enter a X value negative, when I keyboard the letter "-" the message "Invalid value" is displayed.” FIXED

R4911:”The excel report header and summary pages are not correctly aligned, they are too small and some fields are hidden.” FIXED

R4914:”Part temperature not available for API Tracker, Krypton device, Big 3D creator, Leica, GSI, Creaform” FIXED

R4857:”Action with no measuring path and click an element in the graphic --> Error message = HWND of measuring path wizard is NULL” FIXED

R4843:”Measure windows : if you click "set last meas created", it is not send to OPS directly only when you click "Select", but normally clicking select is not necessary if you have already select your meas number” FIXED

R4828:”Display BMP of the star probe configuration is not corresponding to the drawing in toolbuilder (length start from center instead of starting from fixation of the stylus)”FIXED

R4762:”In ISO 2768 : Error message for X value if nominal = 0.00 even if display X is unchecked. Dans les tolérances ISO 2768. Si nominal X=0 mais qu'on ne veut pas voir le résultat X (non coché) et que type de tolérance ISO 2768, type M. Alors quand Apply, message d'erreur, la tolérance n'existe pas pour 0.” DONE – FIXED

Modifications & Bug fixes (patch V400.11 – 2013-10-25):

Wishes Done: R4927:”Add Ctrl Z in sphere and probe calibration windows like other windows” DONE R4944:”Pantec Eagle driver 2.0.9: Serial port or TCP/IP can be used for Controller + Handbox +

PH head” DONE R4945:”AEH Laser Scanner: Check and if necessary inform the user that the laser scanner

parameter file RACPARA.DLL does not exist under Inca3D-Bin directory” DONE R4981:”Baces3D driver: Baces.dll has been removed from Inca3D installation. Now we used the

one installed by Baces3D driver in Baces3D directory. If not found automatically, the user is able to select the location of the Baces.dll directory” DONE

Fixed Bugs:

R4924:”H5 is missing in ISO 286-2 tolerance list” UNI PPS Nr.4561FIXED R4932:”Excel report : All pages have page number 0.” FIXED R4933:”Excel report : If I make a label format of the "Comment" operation with only the comment,

it never appears in the report. I must add a text like "." in a cell in the label to have the comment in my report.” FIXED

R4935:”Cannot read *.asm from PRO-E” FIXED R4937:”Sb CNC + PH/TESASTAR controller connected to the computer: End of head rotation is

not detected. Next DCC move are not executed” FIXED R4926:”Measure 2 points (PANTEC & SB Controller) Software does NOT give results from first

point untill second is measured.” FIXED R4941:”Cannot convert file : 0154015-35_021_Fertigteil_kopie.SLDPRT” FIXED R4922:”import iges with translation +200 Z (cylinder, sphere … and maybe other) are not

translated” FIXED

Page 21: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 21 of 23 Form I3D-VDD001

R4940:”new PC, new install + unzip hotlinemess : but after error message cannot set probe by angle if angle is not set” FIXED

R4936:”Even there is no softkomp.ini or vm.ini, Inca3D create them under "Inca3D Shared" directory” FIXED

R4946:”B&S Leitz protocol: After firmware upgrade of the controller, get error command is no longer compatible.” FIXED

R4954:”Measuring path wizard of circle with a projection plane "new probed" : the parameter distance from circle is used like an integer value !” FIXED

R4955:”I create a new measured Circle with nominal "KB" and actual "Probed". If I change the nominal KB to any other kind then I can have a crash (seldom).” FIXED

R4930:”"Selection machine" action. Should be not printable by default.” DONE – FIXED R4951:”Report in mode “printing selected action in editor” does not work with shortcut report

model1, model2 ..” FIXED R4958:”HotLineMessenger : Sometime the dongle code and extension are missing in the name of

the created file.” FIXED R4947:”In Execution of a variable, cursor is not active in the edit field” FIXED R4959:”If I create a circle with a projection plan "new probed plane" and I am not in mode

"automatic repetition", at the end the circle is not closed and remains opened in the parameter window.” FIXED

R4948:”When creating multiple action (Dist Pt-Pt) warning is displayed, actions can be created anyway” FIXED

R4333:”Each time I convert a CAD file, I get a *.log file in the Inca3D/bin directory. This should be an option or put it in the temporary directory” FIXED

R1747:”With V1617 1. After catia conversion, the files is no more in solid surfaces and most of the surface disappear.” FIXED

R1922:”Conversion error "M532F460420200_A.igs" IGES to BGF” FIXED R2396:”GEOM´TOOL-30754351.091-001-001±±-01.model conversion no error but file is wrong”

FIXED R2462:”CATProduct "07-0722-01.CATProduct" (2145mess.zip) and related catpart cannot be

translate” FIXED R2721:”IGS can’t be converted 061336_gehäuse_schale.igs and 061336_gehäuse_volumen.igs

” FIXED R2722:”0015530105.igs cannot be converted.” FIXED R2758:”Error during the conversion of IGES file. Missing solid in the Catia file.” FIXED R2810:”0017270009.igs, small cone surface in the holes are not correctly converted - display is

wrong - and projection is not possible on unvisible part of the surface” FIXED R2896:”Can not convert VDA file A4517570010.vda 55MB” FIXED R3015:”Surface missing 0016590111.igs” FIXED R3295:”Error during conversion of file _0001-1005.igs . The top surface is not converted.

Previously ok in v2502. The bug occurs when the option High speed conversion is not checked.” DONE – FIXED

R3296:”Crash during conversion of Catia v4 file 311W1531-17_REV-.model” FIXED R3297:”Iges file with small troubles on some surfaces 9687966980.00.DOUB-AIL-AR-D-PAR-

AV.----0002CAT.igs” FIXED R3341:”M5381113120000_ISS_A00.igs cannot be translated” FIXED R3560:”CATIA V4 file cannot be converted. A340-BEPL-UNTEN-LI-UDO.model” FIXED R3569:”542_048_A001_AllCATPart.CATPart cannot be read” FIXED R3687:”CARPET_T6.igs” FIXED R3696:”ANG93531_Frt Dr Surf.igs unknown error” FIXED R3706:”Error during conversion of STEP file: 30100020041501.stp et 30100020045901.step Error when start the tesselation” FIXED R3895:”CAD File of grid, iges version cannot be translated, CATIA is fine” FIXED R4961:”Cannot modify a probed point of the measpath of the Sphere Ctrl 4. We change

coordinates of the 3rd probd point and when click on Apply, the old coordinates are restored.” Pb with check Always recalculate in Wizard. Seems same as R4873 (fixed) FIXED

R4974:”When try to display result of a not validated entity like Complex alignment, catch error in report function.” FIXED

R4975:”When there is no change probe before a new probed action, error message displayed is the wrong one” FIXED

R4982:”I++DME + LK Server: When import tools from I++ LK Server, diameter is equal to 0.0” FIXED

Page 22: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 22 of 23 Form I3D-VDD001

R4983:”Laser AEH : If latest position calibrated is not A0B0, display in laser field center dialog of the laser line is not correct” FIXED

R4979:”Cannot drag and drop entities to a complex / surface alignment. If I drag in the comboboxes the entities, nothing happen.” FIXED

R4985:”When I create a new Gage Point / Change Probe / Machine Parameters / Change rotary table angle action : the result window tab sheet is activated and hide the parameters of the new action.” FIXED

R4986:”When reverse Normal of surface, we don't keep the mesh and we recalculate the mesh. This is not necessary.” FIXED

R4988:”Unable to select output to .xlsx in excel reports” FIXED R4989:”Standard milling tool: If Milling tool direction is Z- display in the graphic is correct (Milling

ball center on milling path), but if switch the milling tool direction to X, Milling ball center is not on the milling path” FIXED

R4993:”When switch from Pantec to Virtual CMM enable "Manage by machine driver" if current Probe driver is PH” FIXED

R4994:”Cannot send several elements from the list of Cad entity to the Ops.” FIXED R4995:”AEH Laser scanner: When display Laser line dialog from Inca3D Counter, close doesnot

close the dialog” FIXED

Modifications & Bug fixes (patch V400.12 – 2013-12-17):

Wishes Done: R5014:”MZ1060: Refactoring of the driver. Kompensation command and Version command can

be now deactivated in Inca.ini if MZ1060 does not support them. Older driver can be reactivated (EnableNewMZ1060Driver.txt)” DONE

Fixed Bugs: R4822:”Symmetrical operation sequence : Error on the vector of the surface point, test on inca

part (shape) then symmetry on X, vector should switch from X+ to X- but stay in X+” FIXED

R5012:”Erreur de conversion du fichier Catia: 3330???3201.CATPart” FIXED R5026:”AEH Laser Scanner: Laser scanner is not display at the right place in graphic view”

FIXED R5031:”TP1, PH1, when set the axis direction of the led or tool direction equivalent to A90 B0,

axis direction selected is not saved” FIXED - R5034 R5032:”Tool head direction on arm is not displayed” FIXED R5033:”Allow to modify manually the start position when calibrate the AEH Laser scanner. Inca3D

move in DCC to the start position then display a dialog that allow to modify this start position” FIXED

R5036:”ZAK: In operation sequence, when call a ZAK without star probe and current ZAK loaded is with star probe and current tip is not #1 we get error message "Tip selected is not available"” FIXED

R5040:”Kreon + Inca3D Virtual CMM: Do not check the calibration file used by Kreon and directory of KreonServer.exe” FIXED

R5041:”Kreon: Inca3D display an error message when try to register the renishaw dll for SP25 even the option for SP25 is not used.” FIXED

R5039:”Alignment 3 pts & Alignment Plane-2pts : Deviations are no more displayed in the GUI Result windows”UNIPPS NR 4854 FIXED

R5038:”Sometimes calculation of roundslot from clicked point on CAD file failed” DONE – FIXED R4343:”Angle calculation between line and plane not perform properly when Line is perpendicular

to the plane” FIXED - R5049 - R3935 R5051:”69111-61M00BEND_003.prt cannot be converted” FIXED R5060:”Calculation of roundslot orientation can sometimes wrong results” FIXED

Page 23: Version Descritpion Document - INSPECT 3D · R3908:”In the form Dev View you can not make bigger/smaler the labels or hide X Y or Z Position of the points (Min Max)” DONE R4063:”Display

VDD_INCA3D_English_2014-02-05_V_4_0_0_14.doc Page 23 of 23 Form I3D-VDD001

Modifications & Bug fixes (patch V400.13 – 2014-01-24):

Wishes Done: R5109:”Intersection Line-Surface: add possibility to make the intersection on surface without

restrictions” DONE R4037:”Sometime need to do intersection line - surface inside a circle restriction (gauge 33-70).

Add "no restriction" flag in this operation.” DONE

Fixed Bugs: R5069:”Sometimes probed point result is sent to earlier regarding the I++ Sequence order”

DONE – FIXED R5065:”with cloud of point, export point to *.IGS show too much warning (takes too much time)”

FIXED R5071:”IGES Export: add extremity circles of cylinder when export cylinder” FIXED R5072:”Automatic calculation of nominal circle from the actual circle is not working when circle is

probed in 1 point (laser tracker or measuring arms)” FIXED R5073:”Cannot see the Zak in the view. The milling tool is displayed in wrong position (Z+ instead

of Z-)” FIXED Add a new kind of Zak ZakMeasMill R5082:”For some counter: Machine parameter cannot be entered” Button is removed in this

case FIXED R5100:”You are in execute mode and when you execute a ops with ANC40 and a gage point is

out of software limit you not get any error message. Machine just stops. When you are in teaching mode and execute the gage point you get the softlimit message.” FIXED

R5104:”New action change probe + ZAK: Do not display the tool selection for ZAK. It disable all button in action Change probe” FIXED

R5108:”In virtual mode, when move out of limits, counter simulation dialog is not displayed in red” FIXED

R5112:”Surface names are changing when sereveral CAD files are loaded and put some of them not visible” FIXED

R5114:”Previously, in Excel repot, cells are filled with an error fo entity not measured. Now, we change and add a message. Problem because customer uses the code inside macro” FIXED add c:\ManageXLErrorWithoutMsg.txt to keep old management

Modifications & Bug fixes (patch V400.14 – 2014-02-05):

Fixed Bugs: R5117:”In automatic repetition and no automatic path wizard calculation, when openning a new

measured circle with a new probed (projection) plane, then clicking on calculate path wizard and saving the operation.Then the next measured circle refuses to calculate the mesuring path” FIXED

R5120:”Approach distance is not taken into account when measuring path wizard has been done once on a mesured point or edge point” FIXED

R5121:”Roundslot calculation failed sometimes when use strategy "Probed with circles (no points on sides)” FIXED UNIPPS #5225

R4858:”Missing parameter in Glossary: Ability to remove "the gage point after" for action points” FIXED