Durable
Enclosures are fabricated from 1.2mm thick
electro galvanized steel sheets.
Fully tested and certified high performance
tin plated bus bar system.
Guaranteed Safety
CAMGRO System is designed and built to
the latest international standards
IEC 61439- 1&2.
Safety is enhanced by thermoplastic barriers
to maintain alignment and isolation between
phases.
Fully shrouded live busbars with dead front
cover and door.
Salient Features
Busbar system is designed for ratings of
125A and 250A.
Wide range of outgoings starting from
12 ways up to 54 ways with a maximum
rating of 63A.
Modular construction.
Electrostatic polyester powder coating in
RAL-7032 shade for corrosion resistance.
Adequate cabling space.
Optimized Maintenance and Operation.
Approved by ADDC and inline with the
requirements of all U.A.E authorities, as well
as inline with the specifications of authorities
in the Gulf countries
Camgro System Final Distribution Boards, delivered
complete with M/s.Schneider Electric components and
integrated within enclosures for high performances up
to 250A for residential, commercial, infrastructure,
industrial and Oil & Gas installations.
Product Features
Wide range of Robust, Reliable and Safe Final Distribution Boards
VERGER et DELPORTE U.A.E. Ltd.
2
Busbar Systems for split type and straight type distribution boards
Technical Specifications
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Outgoing connections up to 63A
Busbar types:
Fully type tested encapsulated busbar system
Tin plated copper Busbars
Main Busbar is suitable for MCCBs/Isolators up to 250A and
RCCBs up to 125A
Rating: 125A Split type and 250A straight Busbar type
Short time Withstand currents(Icw) : 17kA for 0.25Sec (125A),
25kA for 0.2Sec. (250A).
RCCB / ISOLATOR
125A
125A
250A
250AIncoming Rating
MCCBType of Incomer
Busbar Rating
Constructional Characteristics
Complies with IEC 61439-1 & 2.
Totally Type Tested, KEMA / DEKRA certified.
Degree of protection conforms to IP 41 as per IEC 60529.
Enclosure with pan assembly and comb busbar.
Multiple knockout holes at top & bottom gland plate.
Suitable for Surface & Flush mounting
Neutral strip is fixed at left side of the distribution boards.
Earth strip is fixed at Right side of the distribution boards.
Suitable for Wall mounting.
Busbar Systems for din rail type Distribution boards
Outgoing connections up to 63A
Busbar types:
Fully insulated comb busbar system
Busbar is suitable for RCCBs / Isolators up to 125A
Rating: 63A and 125A Comb Busbar
ECONOMY
RCCB / ISOLATOR
63A
63A
125A
125AIncoming Rating
RCCB / ISOLATORType of Incomer
Busbar Rating
VERGER et DELPORTE U.A.E. Ltd.
Electrical Characteristics
Rated Operational Voltage (Ue) : 415V.
Rated Insulation Voltage (Ui) : 415V.
Rated Frequency : 50/60Hz.
Rated Current (In) : up to 250A.
Rated Short Time Withstand Current(Icw) : up to 25KA/0.2sec.
Rated Peak Withstand Current (Ipk) : up to 52KA.
Clearance : > 5.5 mm.
Creepage : > 6.3 mm.
3
Standard range of Moulded Case Circuit Breakers conforming to IEC 60947-2
Technical Specifications
505050Breaking Capacity (Icu)
(kA rms) at 415V
Thermal magnetic or Electronic
100%100%
363636
50/60 Hz
Up to 690V
40A….250ARated current (In)
Rated operational voltage(Ue)
Rated frequency
Protection trip unit
200/250
100%
40….100A 125/160ABreaker Rating
Service Breaking Capacity
Ics…………% Icu
Incoming Devices
CAMGROCAMGROCAMGROCAMGRO SYSTEMSYSTEMSYSTEMSYSTEM
Economy range of Moulded Case Circuit Breakers conforming to IEC 60947-2
3625301510
50%
18
125....250A
Up to 550VRated operational voltage(Ue)
40A…. 250ARated current (In)
50/60 HzRated frequency
Thermal magnetic
50%
7.5
40….100ABreaker Rating
Protection trip unit
Service Breaking Capacity
Ics…………% Icu
Breaking Capacity (Icu)
(kA rms) at 415V
Onload Isolators conforming to IEC 60947-1 / IEC 60947-3
154
100A
154
160A
50/60HzRated frequency
Up to 690VRated Operational Voltage(Ue)
154
125A
40A….250A
75 75
80A
330
250A
75
40A 63A
Rated current (In)
Short-circuit making
capacity Icm (kA peak) with
upstream protection circuit
breaker
Isolator rating
VERGER et DELPORTE U.A.E. Ltd.
4
Boards with 250A incomer can be used as SMDB in certain applications( Approved by ADDC)
Boards with 250A incomer can be used as SMDB in certain applications( Approved by ADDC)*
*
RCCBs conforming to IEC 61008,60947-1 & 60947-3
Technical Specifications
63A40A125A100A80A63A40A
ECONOMY
50/60 HzRated frequency
RCCB Sensitivity (mA) 30….30030…50030…300
NORMAL
Up to 415V
25A….125ARated current (In)
Rated operational voltage(Ue)
Type Of RCCB
25A25A 100ARCCB Rating in Amps
Incoming Devices
CAMGROCAMGROCAMGROCAMGRO SYSTEMSYSTEMSYSTEMSYSTEM
MODULAR ISOLATORS conforming to IEC 60669-1 & IEC 60947-3
125A100A63A40A
50/60 HzRated frequency
Up to 400V
40A….125A Rated current (In)
Rated operational voltage(Ue)
32AIsolator Rating
VERGER et DELPORTE U.A.E. Ltd.
5
Accessories / Auxiliaries
Standard range of Miniature Circuit Breakers conforming to IEC 60947-2
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Technical SpecificationsOutgoing Devices
15kA10kABreaking capacity (Icu)
3P3P
MCB Rating
50/60 HzRated frequency
Up to 415VRated operational voltage(Ue)
6A….63ARated current (In).
6A….63A
1P
6A….63A
1PNo. of pole
Economy range of Miniature Circuit Breakers conforming to IEC 60898
6kABreaking capacity (Icu)
MCB Rating
50/60 HzRated frequency
Up to 400VRated operational voltage(Ue)
6A….40ARated current (In).
6A…40A
3P
6A...40A
1PNo. of pole
Residual Circuit Breaker with Overload. (RCBO) conforming to IEC 61009 )
10kABreaking capacity (Icu)
50/60 HzRated frequency
30 100
6A….45A6A….45A6A….45ARCBO Rating
10RCBO Sensitivity (mA)
1PNo. of pole
Up to 250VRated operational voltage(Ue)
6A….45ARated current (In).
RCCB ‘ OF ’
contact
Padlocking device Blanking
Plate
‘ MX’ for MCB ‘ OF’ for MCB ‘ MN’ for MCB
VERGER et DELPORTE U.A.E. Ltd.
OF : Display contact MX : Shunt opening release MN : Under voltage release
6
Selection Process
CGF N 12 N FD CAMGRO System
No. of Outgoing ways
12 : 12 ways
18 : 18 ways
24 : 24 ways
30 : 30 ways
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Selection of straight Busbar type Final Distribution Boards
N : Standard Range of MCBs
E : Economy range of MCBs
NR : Combination of Standard MCBs and RCBOs
ER : Combination of Economy MCBs and RCBOs
Incoming breaker type
Door Type
FD : Flush Door
SD : Surface Door
Outgoing breaker type
36 : 36 ways
42 : 42 ways
48 : 48 ways
54 : 54 ways
Economy Range of MCCB
E : MCCB
Standard Range of MCCB
N : MCCB
Isolator( 160A….250A )
IS : Isolator
RCCB / Isolator
R : RCCB
I : Isolator ( 32A….125A )
Dimensions
145
145
145
145
118
118
118
D
145
145
145
145
118
118
118
D
1000
850
690
530
850
690
530
H1
1032
882
722
562
882
722
562
H
4571017472100042W, 48W
54W
45786747285024W30W,
36W
45770747269018w
45754747253012w,
45770747269030W, 36W
42W
867
547
H
SURFACE
457
457
W
472
472
W
850
530
H1
FLUSH
12W
18W, 24W
48W,54W
NO. OF
WAYS
MCCB or
160….250A isolator
Incomer
RCCB or
32A…125A
isolator Incomer
VERGER et DELPORTE U.A.E. Ltd.
7
Selection Process
CGF N 66 1RI2R FD CAMGRO System
66 : 6 + 6 way
612 : 6 + 12 way
618 : 6 + 18 way
1212 : 12 + 12, way
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Selection of Split Busbar Type Final Distribution Boards
N : Standard Range of MCBs
E : Economy range of MCBs
NR : Combination of Standard MCBs and RCBOs
ER : Combination of Economy MCBs and RCBOs
Incoming breaker type
Door Type
FD : Flush Door
SD : Surface Door
Outgoing breaker type
1218 : 12 + 18 way
1224 : 12 + 24 way
1230 : 12 + 30 way
1236 : 12 + 36 way
Main Incomer
I : Isolator
Dimensions
1000
850
690
530
H1
1000
850
690
530
H1
457
457
457
457
W
1017
867
707
547
H
SURFACE
47210322430, 1836
472
472
472
W
882
722
562
H
FLUSH
1224, 1230,
1236, 1818,
1824, 1830,
2424
66
612, 1212,
618, 1218
NO. OF WAYS
No.of Outgoing Ways ( Single pole ways)
1818 : 18 + 18 way
1824 : 18 + 24 way
1830 : 18 + 30 way
1836 : 18 + 36 way
Section – 1 RCCB
1R : RCCB
Section – 2 RCCB
2R : RCCB
VERGER et DELPORTE U.A.E. Ltd.
8
2424 : 24 + 24 way
2430 : 24 + 30 way
Selection Process
CGF N 6 R FD CAMGRO System
No. of Outgoing ways (Single pole ways)
6 : 6 ways
8 : 8 ways
12 : 12 ways
16 : 16 ways
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Selection of Single Phase Final Distribution Boards
N : Standard Range of MCBs
E : Economy range of MCBs
Incoming breaker type
Door Type
FD : Flush Door
SD : Surface Door
Outgoing breaker type
R : RCCB - 2P
I : Isolator – 2P
Dimensions
2972412243122562246 WAYS
457
385
313
W
440
368
296
W1
SURFACE
297
297
297
H
472
400
328
W
31244016 WAYS
312
312
H
368
296
W1
FLUSH
12 WAYS
8 WAYS
NO. OF
WAYS
RCCB or isolator
Incomer
VERGER et DELPORTE U.A.E. Ltd.
9
Selection Process
CGR N 1R R FD CAMGRO System
No. of Rows
1R : 1 Row
2R : 2 Row
3R : 3 Row
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Selection of Din rail Type Final Distribution Boards
N : Standard Range of MCBs
E : Economy range of MCBs
Door Type
FD : Flush Door
SD : Surface Door
Outgoing breaker type
4R : 4 Row
5R : 5 Row
6R : 6 Row
457
457
457
457
457
457
457
457
W
472
472
472
472
472
472
472
472
W
SURFACE
HH1
13471330136213308 ROW
11971180121211807 ROW
10471030106210306 ROW
8978809128805 ROW
7477307627304 ROW
597
447
297
580
430
280
H1
612
462
312
H
580
430
280
FLUSH
3 ROW
1 ROW
2 ROW
NO. OF ROWS
Dimensions
7R : 7 Row
8R : 8 Row
Incoming breaker type
R : RCCB
I : Isolator
VERGER et DELPORTE U.A.E. Ltd.
10
Certificates
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
125A Split Type & 250A Distribution Boards Type Tested Certificates
CAMGRO F1 SYSTEM
125A Split type Final Distribution BoardCAMGRO F2 SYSTEM
250A Distribution Board
CAMGRO F1 SYSTEM
125A Split type Final Distribution Board
Short Circuit Test
CAMGRO F2 SYSTEM
250A Distribution Board
Short Circuit Test
VERGER et DELPORTE U.A.E. Ltd.
11
CAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEMCAMGRO SYSTEM
Contact us
Website : www.verger-delporte.ae Email - [email protected]
Head Office - Sharjah Dubai & Northern EmiratesAbu Dhabi & Al Ain
M. Ramakrishna,
Manager,
P O Box : 5629,
Sharjah, UAE.
Mobile : 00971 50 6314057,
Tel : 00971 6 5432436,
Fax : 00971 6 5434139,
Email : [email protected]
Madhu Murthy Arza
Sales Manager,
P O Box : 5629,
Sharjah, UAE.
Mobile : 00971 50 4620874,
Tel : 00971 6 5432436,
Fax : 00971 6 5434139,
Email : [email protected]
Krishnaraj,
Assistant Manager,
P O Box : 47010,
Abu Dhabi, UAE.
Mobile : 00971 50 7971556,
Tel : 00971 2 6727317,
Fax : 00971 2 6729699,
Email : [email protected]
VDS201107/002, 09-08-2011, REV - 0 12
VERGER et DELPORTE U.A.E. Ltd.