vehc_30_0 fueller general schematic
DESCRIPTION
Fueller General SchematicTRANSCRIPT
-
Prepared by : .................................................................... Air BP K S Murray Approved by : .................................................................... Air BP K R Massey
Document : VEHC 30
FUELLER GENERAL SCHEMATIC
Issue : 0 Date : 15 February, 2000
AIR BP LIMITED BREAKSPEAR PARK BREAKSPEAR WAY HEMEL HEMPSTEAD HERTFORDSHIRE, HP2 4UL ENGLAND, UNITED KINGDOM
-
AIR BP VEHC_30_0.doc - Page i
REVISION RECORD Issue Date Reason for Revision
0 15/02/00 Initial Issue Document
Copyright Air BP Limited All rights reserved. This document and the information it contains, or may be extracted from it, is subject to the terms and conditions of the agreement or contract under which the document was supplied to the recipient's organisation. None of the information contained in this document shall be disclosed outside of the recipient's own organisation without prior written permission of Air BP Limited, unless the terms of such agreement expressly allow.
-
AIR BP VEHC_30_0.doc - Page ii
CONTENTS
SECTION PAGE
1.1. Fueller General Schematic 4 1.2. Dispenser General Schematic 4 1.3. Basic Fueller Schematic 5 1.4. Basic Fueller Schematic - Option 1 5 1.5. Additional Fueller Components 6
-
AE
Sampling station
Main Product Lines
Defuel Lines
Samplng linesDefuel interlocks
MP MP
Outsidesuction
Not shown
Pipework thermal reliefFilter Pd gaugeVenturi sense lines
Fueller General Schematic
Sample jarFlexible joint
Sho Flo
Spring return ball valve
Deadman valve
Venturi
Dry break connection
Footvalve
Lever operated ball valve
Meter
Overwing
Recovery tank
Underwing
Platform
Deck hosetest points
Defuel
Trailer tankconnection
Air BP Jan 2000
Fig 1.1
AE
Sampling station
Platform
MP MP
Not shown
Pipework thermal reliefFilter Pd gaugeVenturi sense lines
Dispenser General Schematic
Sample jarSho Flo
Spring return ball valve
Deadman valve
Venturi
Lever operated ball valve
Meter
Underwing
Recovery tank
Intake coupling
Swivel joint
Main Product Lines
Samplng lines
Intake line
ShockAlleviator
Air BP Jan 2000
Fig 1.2
-
AE
Sampling station
Main Product Lines
Defuel Lines
Samplng linesDefuel interlocks
MP MP
Not shown
Pipework thermal reliefFilter Pd gaugeVenturi sense lines
Basic Fueller Schematic
Flexible joint
Sho Flo
Spring return ball valve
Deadman valve
Venturi
Dry break connection
Footvalve
Lever operated ball valve
Meter
Overwing Underwing
Recovery tank
Sample jar
Air BP Jan 2000
Fig 1.3
AE
Sampling station
Main Product Lines
Defuel Lines
Samplng linesDefuel interlocks
MP MP
Not shown
Pipework thermal reliefFilter Pd gaugeVenturi sense lines
Basic Fueller Schematic - Option 1
Flexible joint
Sho Flo
Spring return ball valve
Deadman valve
Venturi
Dry break connection
Footvalve
Lever operated ball valve
Meter
Overwing Underwing
Recovery tank
Sample jar
Air BP Jan 2000
Fig 1.4
-
Outsidesuction
Additional Fueller Components
Trailer tankconnection
Defuel
Deck hosetest points
Platform