CASE STUDY BEFORE AFTER BEFORE AFTER Virginia Commonwealth University - Snead Hall The Project In 2008, President Emeritus Eugene P. Trani, Ph.D. of Virginia Commonwealth University, signed the American College and University Presidents’ Climate Commitment which added significant dollars to their budget while making environmental changes to the University. In efforts to reduce emissions in all areas of VCU’s campus life; in November 2012, VCU decided to retrofit the exterior lighting of Snead Hall, home of the VCU School of Business. The Solution The solution came in the form of LitespanLED® Post-Top Replacements lamps from EiKO Ltd – retrofitting 604 of VCU’s existing acorn fixtures of 150W High Pressure Sodium lamps. EiKO’s LitespanLED® Post-Top replacement lamp provides 105 lumens per watt with a long life of 60,000 hours, saving time and energy by requir- ing fewer replacements over time. LitespanLED® Post-Top LED Replacement lamps maintain greater than 90% of initial light output after 60,000 hours.

Upload: others

Post on 18-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: VCU - Snead Hall Case Study JE - Mid-Atlantic Lighting Case Study.pdf · CASE STUDY BEFORE AFTER BEFORE AFTER Virginia Commonwealth University - Snead Hall The Project In 2008, President

CASE STUDY

BEFORE AFTER

BEFORE AFTER

Virginia Commonwealth University - Snead Hall

The ProjectIn 2008, President Emeritus Eugene P. Trani, Ph.D. of Virginia Commonwealth University, signed the American College and University Presidents’ Climate Commitment which added significant dollars to their budget while making environmental changes to the University.

In efforts to reduce emissions in all areas of VCU’s campus life; in November 2012, VCU decided to retrofit the exterior lighting of Snead Hall, home of the VCU School of Business.

The SolutionThe solution came in the form of LitespanLED® Post-Top Replacements lamps from EiKO Ltd – retrofitting 604 of VCU’s existing acorn fixtures of 150W High Pressure Sodium lamps. EiKO’s LitespanLED® Post-Top replacement lamp provides 105 lumens per watt with a long life of 60,000 hours, saving time and energy by requir-ing fewer replacements over time.

LitespanLED® Post-Top LED Replacement lamps

maintain greater than90% of initial light output

after 60,000 hours.

Page 2: VCU - Snead Hall Case Study JE - Mid-Atlantic Lighting Case Study.pdf · CASE STUDY BEFORE AFTER BEFORE AFTER Virginia Commonwealth University - Snead Hall The Project In 2008, President

CASE STUDY

VCU

AFTER

Burning Cycle• Hrs/Day 12• Days/Wk 7• Weeks/Yr 52• Annual Hour Total 4,380• Total kWh Savings 378,309kWh

Return on Investment • Retrofit installation costs $135,900• Total Annual Savings $63,025• Years to Payback on Investment 2.16 years• Total Lifetime Savings of Post-Top LED* $863,438 *60,000 life hours over 13.7 years

Cost of Light Analysis:

EiKO LitespanLED® Post-Top Replacement Lamps The Virginia Commonwealth University courtyard lit at night

AFTER

$-

$10,000.00

$20,000.00

$30,000.00

$40,000.00

$50,000.00

$60,000.00

$70,000.00

$80,000.00

$90,000.00

$100,000.00

HPS Post-Top LED

ANNUAL LIGHTING COST COMPARISON

Labor

Lamps

Lamp Energy