vcc-ft21b assembly instructions–packaging contents
TRANSCRIPT
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
2
2
3
4
6
7
8
1
5
9
Channels (2X)
M8 Spacer (6X) Foam Gasket (6X)
End Caps (4X)
Brackets (4X)
Connect Plate (6X)
M8 X 35MM (6X)
Foam Pad (6X)
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–PA
CK
AG
ING
CO
NTE
NTS
1—FBM-0010 ........................................................ (Qty 1) Channels with hardware
CONTENTS OVERVIEW
2—Rear Crossbar Assembly .................................. (Qty 1)
3—Front Crossbar Assembly ................................. (Qty 1)
4—Handle Latch Assembly ................................... (Qty 2)
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
3
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–PA
CK
AG
ING
CO
NTE
NTS
7—Quick Clamp Tube Splice Assembly ................ (Qty 2) 5.00“
9—HD Front Hook Assembly ................................. (Qty 2)
6—Clamp Down Tube ............................................ (Qty 2) 80.00”
8—Removeable Horn with Cap ............................. (Qty 2) 15.00”
ASZ-0101 (1X)
10—Anti-Seize ........................................................ (Qty 1)
5—Clamp Down Handle Assembly ....................... (Qty 2)
BLT-6846-M8 (1X)
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
4
Rear
FrontLeft
Right
Rear
FrontLeft
Right
Rear
FrontLeft
Right
Left Rear
72.00”
Flush to end
Right Rear
5.00”
Channel Front
4.75”
Channel Rear
Fig. 1
72.00”
Flush to end
Metal Spacer
Foam Gasket
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–FB
M M
OU
NTI
NG
SFBM-0010 CHANNELS TO ROOF
Slide Channel Connectorsinto Channels as shown
0.6 Loosen bolts
0.7 Set to distances then torque Rear Bracket nuts to 90 in-lbs
Install Channels into roof Channel groove as shown0.3
Position Channels asshown below in Fig.10.1
0.20.4
0.5
Install fasteners into factory roof rail mounting locations.
Torque to 150 in-lbs.
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
5
1
1
Rear
FrontEven EvenFront
Even EvenRear
CROSSBAR INSTALLATION SEQUENCE
CROSSBARS CROSSBAR ADJUSTMENT
1.1
Torque to 90 in-lbs 1.2
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–R
IGH
T SI
DE
CLA
MP
DO
WN
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
6
2
3
4
5
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–R
IGH
T SI
DE
CLA
MP
DO
WN
RIGHT CLAMP DOWN ASSEMBLY SEQUENCE
CLAMP DOWN HANDLE CLAMP DOWN TUBE
2
3.2
3.1
3.3
3.4
Torque to 90 in-lbs
Torque to 90 in-lbs
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
7
VCC
-FT2
1B A
SSEM
BLY
INST
RUCT
ION
S–RI
GH
T SI
DE
CLA
MP
DO
WN
HANDLE LATCH FRONT LADDER HOOKSEE QUICK START GUIDE FOR ADJUSTMENTS
4.2 Torque to 90 in-lbs
4.1
5.2
Torque to 90 in-lbs
5.1
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
8
6
7
8
9
VC
C-F
T21B
ASS
EMB
LY I
NST
RU
CTI
ON
S–LE
FT S
IDE
CLA
MP
DO
WN
LEFT CLAMP DOWN ASSEMBLY SEQUENCE
CLAMP DOWN HANDLE CLAMP DOWN TUBE
6
7.2
7.1
7.3
7.4
Torque to 90 in-lbs
Torque to 90 in-lbs
PRIME DESIGN, A SAFE FLEET BRAND 1689 Oakdale Avenue #102, West St Paul, Minnesota 55118 ▪ Phone: 651-552-8554 ▪ 1.8.PRIME.RACK ▪ Fax: 651-552-1799 ▪ Email:[email protected] ▪ www.primedesign.netTM & © 2015 PRIME DESIGN. PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENT NO.’s 6092974, 6764268, 6971563, 2364879, 8857689, 8511525, 8991889 AND OTHER PATENTS PENDING
9
VCC
-FT2
1B A
SSEM
BLY
INST
RUCT
ION
S–LE
FT S
IDE
CLA
MP
DO
WN
HANDLE LATCH FRONT LADDER HOOKSEE QUICK START GUIDE FOR ADJUSTMENTS
8.2Torque to 90 in-lbs
8.1
9.2Torque to90 in-lbs
9.1
ADDITIONAL INFORMATIONFor additional information regarding your VCC-FT21B Ladder Rack, please visit the Prime Design website at: www.primedesign.net. Using a QR code reader in your smart phone or tablet, read the QR Code shown below and follow the same steps as you would from your laptop or computer. If you’re viewing this document as an interactive PDF, you may simply click on the QR Code below to access the Prime Design website.
Page Intentionally Left Blank
Page Intentionally Left Blank
USAM-VCCFT21B-US01 Rev-A 0715