EMH metering GmbH & Co. KG • Südring 5 • 19243 Wittenburg • GERMANY • Tel. +49 38852 645-0 • [email protected] • www.emh-metering.com EMH metering GmbH & Co. KG Südring 5 19243 Wittenburg GERMANY Tel. Fax E-mail Web EN +49 38852 645-0 +49 38852 645-129 [email protected] www.emh-metering.com Edition: 28.07.2010 VARIOMOD-DAB-E-2.00 VARIOMOD Meter-Modems Transparent data readout, suitable for all common control centres Password protection (readout and/or remote configuration) Interfaces: RS485, RS232 or CL (switchable online) Long-range power supply 3 point mounting acc. to DIN 43861-2

Upload: thomaswangkoro

Post on 16-Apr-2015

78 views

Category:

Documents


6 download

DESCRIPTION

The modem for communication protocol of EMH meter

TRANSCRIPT

Page 1: Variomod Brochure

EMH metering GmbH & Co. KG • Südring 5 • 19243 Wittenburg • GERMANY • Tel. +49 38852 645-0 • [email protected] • www.emh-metering.com

EMH meteringGmbH & Co. KG

Südring 519243 WittenburgGERMANYTel.Fax

E-mail Web

EN

+49 38852 645-0+49 38852 645-129

[email protected]

Edition: 28.07.2010VARIOMOD-DAB-E-2.00

VARIOMOD Meter-ModemsTransparentdatareadout,suitableforallcommoncontrolcentres

Passwordprotection(readoutand/orremoteconfiguration)

Interfaces:RS485,RS232orCL(switchableonline)

Long-rangepowersupply

3pointmountingacc.toDIN43861-2

Page 2: Variomod Brochure

Productspecificationsaresubjecttochangewithoutnotice!

VARIOMODgprs VARIOMODgsm VARIOMODethernet VARIOMODanalog

Supply voltagecurrentfrequencypowerconsumption

100...240VAC(±10%),135V...240VDC(±10%)max.0,25A50...60Hz

max.5VA(CL1active,load=1000Ω),UB=240VAC,atleast0,9VA(RS232active),UB=100VAC

100...240VAC(±10%),135V...240VDC(±10%)max.0,25A50...60Hz

Real Time Clock (option)

accuracysynchronisationrunningreservecapacitor

within±5ppmviaelectricaldatainterface

approx.5days

within±5ppmviaelectricaldatainterface

approx.5days

Control input systemvoltage controlofthecallacceptanceoralarm-/messageinputforsendinganSMSandE-mail

controlofthecallacceptanceoralarm-/messageinputforsendinganSMS

alarm-/messageinputforsendinganE-mail controlofthecallacceptanceoralarm-/messageinputforsendinganSMS

Displays 5LEDs Power,Signal,Connect,OnlineandError Power,Signal,Connect,OnlineandError

Data interfaces electricaldatainterfacedataprotocolstransmissionrates

RS485,RS232andCL1(switchableonline),option:2xRS485andCL1(switchableonline)IEC62056-21(7E1),DLMS(8N1),ModeC,ModeE,transparent

300upto19200baud

RS485,RS232andCL1(switchableonline),option:2xRS485andCL1(switchableonline)IEC62056-21(7E1),DLMS(8N1),ModeC,ModeE,transparent

300upto19200baud

Safety / EMC safetynoiseimmunityradiodisturbance

EN60950-1(2001)EN55024(1998)+A1(2001)+A2(2003)EN55022(1998)+A1(2000)+A2(2003)

EN60950-1(2001)EN55024(1998)+A1(2001)+A2(2003)EN55022(1998)+A1(2000)+A2(2003)

Temperature range specifiedoperatingrangelimitrangeforstorageandtransport

-10°C...+55°C

-25°C...+70°C

-25°C...+55°C

-40°C...+80°C

Relative humidity 0...95%,non-condensing 0...95%,non-condensing

Housing dimensionsmountingdegreeofprotection:housing

105x175x74(WxHxD)mm 3pointmountingacc.toDIN43861-2orwallmounting

IP54

105x175x74(WxHxD)mm 3pointmountingacc.toDIN43861-2orwallmounting

IP54

Weight approx.420g approx.420g approx.420g approx.400g

Terminals springterminalsantennaconnection

2,5mm²single-wireorfine-wired;1,5mm²fine-wiredincl.connectorsleeveFMEsleeve

2,5mm²single-wireorfine-wired;1,5mm²fine-wiredincl.connectorsleeve

Functions callacceptancecallacceptancedelaypasswordprotectionconfiguration+firmwareupdate

operationsafety

viatimeslotsorcontrolinput1...15ringsignal(configurable)

2independentpasswordlevels,configurationandtransparentmodeviatelephonenetworkor

locallyviaelectricaldatainterfacesintegratedwatchdog,automaticreset(configurable)

2independentpasswordlevels,configurationandtransparentmode

integratedwatchdog,automaticreset(configurable)

Telephone connection

connectionprotocols

compressionerrorcorrectionconformitydialingprocess

---

------------

---

------------

---

------------

V.34,V.32bis,V.32,V.29FC,V.23,V.22bis,V.22,Bell212AV.21,Bell103

V.42bis,MNP5V.42,MNP2-4CTR21/TBR21

multi-frequencytonedial

GSM wavelengthtransmissionperformanceconnectionprotocolscompressionerrorcorrection

quadband850/900/1800/1900MHzmax.2Wwith850/900MHz;max.1Wwith1800/1900MHz

V.21,V.22,V.23,V.22bis,V.26ter,V.32,V.34,V.110V.42bisMNP2

---------------

---------------

GPRS class class10upto2uplinks,upto4downlinks;

maximum5links

--- --- ---

Network Ethernet

IPaddressallocationmodedatatransmission

---

---TCP/IPServer,FTP,IPT,SMTP(Mail)

---

------

IEEE802.310BaseT/100BaseTxautonegotiation,Auto-MDI(X)DHCPorfixedIP-address

TCP/IPServer,FTP,IPT,SMTP(Mail)

---

------

Scope of delivery antenna

softwaredocumentsconnectioncable(optional)telephoneconnection

magneticfixingantennawith2,5mconnectioncableVariomodManager

operation-andinstallationguide------

magneticfixingantennawith2,5mconnectioncableVariomodManager

operation-andinstallationguide------

---

VariomodManageroperation-andinstallationguide

RJ45networkcable---

---

VariomodManageroperation-andinstallationguide

---TAE-Nplug,cablelength3m(standard)

ThemetermodemVARIOMODisavailableasanGPRS-,GSM-,Ethernet-andAnalog-modem.Duetothepossibilityoftransparentdatareadoutthemodemsaresuitableforallcommoncontrolcentres.ThemodemsareequippedwithaRS485-,RS232-andCL-interface.Furthermore1alarmcontactisavailable.

--- ---

------

viaethernetorlocallyviaelectricaldatainterfaces

viatimeslotsorcontrolinput1...15ringsignal(configurable)

viatelephonenetworkorlocallyviaelectricaldatainterfaces

Meter-ModemVARIOMOD

TheVARIOMODfunctionscanbeextentedwiththefollowingaccessories:

ExternalStationAerial

Parameterisationsoftware

max.5VA(CL1active,load=1000Ω),UB=240VAC,atleast0,9VA(RS232active),