varian truebeam
DESCRIPTION
Varian TrueBeam. Alamance Regional Cancer Center 2012. Varian TrueBeam. Why Varian TrueBeam?. New platform technology Improved imaging Efficiency Fast and precise Upgradability Most reliable equipment Unlocks treatments Enhanced patient comfort. Varian TrueBeam. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/1.jpg)
Varian TrueBeamAlamance Regional Cancer Center 2012
![Page 2: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/2.jpg)
Varian TrueBeam
![Page 3: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/3.jpg)
Why Varian TrueBeam? New platform technology Improved imaging Efficiency Fast and precise Upgradability Most reliable equipment Unlocks treatments Enhanced patient comfort
![Page 4: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/4.jpg)
Varian TrueBeam
![Page 5: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/5.jpg)
New Beam Generation System• All new accelerator guide• Variable energy switch• Simplified and integrated bend magnet• New energy/foil carousel and target system• Real-time electron gun gating• Maximum flexibility in dosimetry <5
MU/min up to 2400 MU/min
![Page 6: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/6.jpg)
New Beam Generation System• The TrueBeam system has been
designed from the ground up to optimize radiotherapy and radiosurgery
• Delivers powerful cancer treatments with pinpoint accuracy and precision
• Seamless integration of treatment, imaging and motion management
![Page 7: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/7.jpg)
Radically Different Future• Designed to optimize radiotherapy and radiosurgery• Integrates and choreographs powerful imaging and
treatment systems• Unparalleled accuracy• Unlocks new treatment options• Allows patients to receive radiation with less
treatments• Treats new cancers that were previously untreatable
![Page 8: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/8.jpg)
More Treatment Options• Provide more options for treating
complex cancer cases including lung, breast, liver, abdomen, head and neck
• IMRT, IGRT, RapidArc, Gated RapidArc, SBRT, SRS
![Page 9: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/9.jpg)
Gated RapidArc• Next evolutionary step• Compensates for tumor motion• Expands application of RapidArc
treatments to moving tumors• Enables fast treatments
of tumors that move with respiration• Minimizes exposure to healthy tissues
![Page 10: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/10.jpg)
Gated RapidArc
![Page 11: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/11.jpg)
Multiple Energy Support• 6 X-ray energies• 8 electron energies• Tailor treatments to individual patients• Select optimal energy for specific clinical
need
![Page 12: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/12.jpg)
Improved CBCT Quality• Overall, better image uniformity• Cupping artifact has been minimized -
apparent when performing window and level
• Improvement in the skin line definition• Better HU accuracy under
all conditions
![Page 13: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/13.jpg)
Imaging on Demand• Higher capacity X-ray tube• Acquire a radiograph,
CBCT image, or perform fluoroscopy, anytime
• Automated filter management• Variable collimation
![Page 14: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/14.jpg)
New Standards in Accuracy• Mechanical and Imaging Isocenter
Accuracy < 0.75 mm• Gantry rotational:
< 0.3 degrees• Collimator rotational:
< 0.5 degrees
![Page 15: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/15.jpg)
Submillimeter Couch Accuracy• Compensates for
mechanical deflection• Rotational accuracy
for patient positioning 0 to+ 6 degrees: < 0.4 degrees
• Spatial translational accuracy for patient positioning+ 5 cm shift: < .5 mm
![Page 16: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/16.jpg)
Unrivaled Treatment Precision• All within 10 milliseconds• Accuracy in increments of less than a
millimeter• Submillimeter alignment for imaging and
treatment isocenter
![Page 17: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/17.jpg)
• One button image acquisition and full automation of beam delivery make treatments 50% faster*
• Changing imaging procedures and protocols is simple and fast
• Position and treat in less time than RapidArc benchmark
50%
Faster
![Page 18: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/18.jpg)
TrueBeam™
Treatment Console
![Page 19: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/19.jpg)
![Page 20: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/20.jpg)
Fast and Precise
Synchronized Imaging & Delivery
= Fast & Precise Treatments
![Page 21: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/21.jpg)
Enhanced Image Guidance• Simplified, Automated Imaging Modes• Image Acquisition during Treatment—kV
and MV• Respiration synchronized kV and MV
Imaging
![Page 22: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/22.jpg)
TrueBeam
![Page 23: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/23.jpg)
TrueBeam
![Page 24: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/24.jpg)
Enhanced Patient Comfort
![Page 25: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/25.jpg)
Built with Patient Comfort in Mind• Quiet operation provides for more
comfortable environment• Shorter treatment times, less
interruption to patient’s daily lives• Music can be played during treatments
to increase patient comfort
![Page 26: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/26.jpg)
Enhanced Patient Interaction• Constant interaction between the
patient and therapist• New communication system enables the
therapist to monitor the patient from outside the treatment room
![Page 27: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/27.jpg)
Allow More Time with Patient• Guided workflow • Streamlined tasks• Prompted and predicted next steps• Common user interface for Console,
Pendant and Couch controls
![Page 28: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/28.jpg)
Why Varian TrueBeam?
![Page 29: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/29.jpg)
Varian2100C
ElektaInfinity
VarianTrueBeam
BeamShaping
Cerrobend Blocks
MLCs MLCs
Imaging Radiographicfilms taken and processed. Time. Poor image quality.
OBI-CBCT/kV images. IGRT-Image Guided Radiation Therapy.
OBI- CBCT/kV images. IGRT-Image Guided Radiation Therapy.
Precision Only 3-D and simple treatments available due to manual blocking requirement
Offers MLCs, but No FFF energies
MLCs , image quality and FFF energies allows SBRT, SRS and Rapid Arc treatments
Speed ofTreatment
Slow due to manual blocking.600MU/min
Std speed for IMRT and Arc Therapy, but No FFF capability
State-of-the-art platform, SBRT and SRS speed using 2400 MU/min
Energies Up to 7 Energies from 4 to 25 Mv
8 Electron Energies5 Flattened Photon Energies Fast High Intensity Mode–6X FFF: max ~1400 MU/min–10X FFF: max ~2400 MU/min
![Page 30: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/30.jpg)
Varian2100C
ElektaInfinity
VarianTrueBeam
Retired platform Platform comparable to Varian’s C series.
New platform allowing software enhancements to extend product life to the upper limit of typical.
Imaging poor quality due to mV imaging
No High Intensity energies for SBRT/SRS.
High Intensity energies
Full 1st digital linear accelerator intro 1985
Elekta no fully integrated system. TPS is 3rd party
First linear accelerator developed with Stanford in 1959. Dedicated to oncology. Largest oncology specific software provider of fully integrated radiotherapy systems.
Main Differences
![Page 31: Varian TrueBeam](https://reader033.vdocuments.site/reader033/viewer/2022061413/56816274550346895dd2e5b9/html5/thumbnails/31.jpg)
Thank you for your support.Questions?