vaporizzatore storz & bickel - plenty - manuale di avvio rapido >> by puntog

2
4. Switch on the device (orange power switch) and press auto off release handle. Quick Start Manual PLENTY Vaporizer STORZ & BICKEL GMBH & CO. KG · In Grubenäcker 5-9 · 78532 Tuttlingen/Germany STORZ & BICKEL AMERICA, INC. · 1078 60 th Street, Suite A · Oakland · CA 94608 · USA Refer to the Instructions for Use for important safety and user advice. Do not operate the device without first reading and understanding the Instructions for Use! 130°C 266°F 142°C 288°F 154°C 310°F 166°C 331°F 178°C 352°C 190°C 374°F 202°C 396°F Completely filled Filling Chamber correct vapor Filling Chamber only partially filled wrong hot air correct Filling Chamber only partially filled, with Liquid Pad placed on top vapor 5. Vaporization temperature scale 6. Choose temperature www.storz-bickel.com Always fill the Filling Chamber completely up to the upper edge 1. Open Filling Chamber 3. Fill Filling Chamber 2. Grind materials Correct Filling

Upload: puntog-head-shop-vape-shop-hemp-shop

Post on 22-Mar-2017

10 views

Category:

Devices & Hardware


4 download

TRANSCRIPT

Page 1: VAPORIZZATORE STORZ & BICKEL - PLENTY - MANUALE DI AVVIO RAPIDO >> By PuntoG

4. Switch on the device (orange power switch) and press auto off release handle.

Quick Start ManualPLENTY Vaporizer

STORZ & BICKEL GMBH & CO. KG · In Grubenäcker 5-9 · 78532 Tuttlingen/Germany

STORZ & BICKEL AMERICA, INC. · 1078 60th Street, Suite A · Oakland · CA 94608 · USA

Refer to the Instructions for Use for important safety and user advice. Do not operate the device without first reading and understanding the Instructions for Use!

130°C266°F

142°C288°F

154°C

310°F

166°C

331°F

178°C

352°C

190°C374°F

202°C396°F

Completely filled Filling Chamber

correct

vapor

Filling Chamber only partially filled

wrong

hot air

correct

Filling Chamber only partially filled, with Liquid Pad placed on top

vapor

5. Vaporization temperature scale

6. Choose temperature

w w w. s to r z - b i c ke l . c o m

Always fill the Filling Chamber completely up to the upper edge

1. Open Filling Chamber

3. Fill Filling Chamber

2. Grind materials

Correct Filling

Page 2: VAPORIZZATORE STORZ & BICKEL - PLENTY - MANUALE DI AVVIO RAPIDO >> By PuntoG

w w w. s to r z - b i c ke l . c o m

Disassembling, Cleaning, Assembling

STORZ & BICKEL GMBH & CO. KG · In Grubenäcker 5-9 · 78532 Tuttlingen/Germany

STORZ & BICKEL AMERICA, INC. · 1078 60th Street, Suite A · Oakland · CA 94608 · USA

© b

y S

TO

RZ

& B

ICK

EL

Gm

bH

& C

o. K

G ·

PA

L-3

0-0

92

09

-201

6 ·

Su

bje

ct to

alte

ratio

ns

· All

rig

hts

rese

rve

d

Mouthpiece

Upper Tubing Section (long)

Cooling Coil

Lower Tubing Section (short)

Filling Chamber Cap

Upper Screen

Lower Screen

Filling Chamber Cylinder

Filling Chamber Housing

3. Pull the Cooling Coil out of the Filling Chamber Cap

4. Push out the Upper Screen with help of the Cleaning Brush

5. Disassembling the Filling Chamber

7. Push out the Lower Screen

1. Expanded view of the PLENTY Vaporization Unit

2. Pull the Mouthpiece away from the Cooling Coil

6. Push out the Filling Chamber Cylinder

8. Manual cleaning with alcohol (min. 90%) or dishwashing soap

9. Filling Chamber Cylinder, Filling Chamber Housing, positioning surfaces