vante pirf ii catheter manufacturing system
TRANSCRIPT
19
25
17
905
1
4X
8X
4X
14
906
122X
4
6
5
The Vante PIRF® II System, utilizing precision energy control and heat placement, is specifically designed for small profile catheter manufacturing. A proprietary mold design concentrates heat to an area as small as 1mm for tipping and butt weld applications. The temperature control and precise heat placement of this system are especially critical in controlling flash and achieving quality welds of braided materials as well as materials with significant durometer differences. The Vante PIRF II System consists of a model 3220 RF generator and one of three forming platforms, depending on the gripping and insertion force requirements of the specific application. All platforms can be teamed with a variety of tipping, welding, and forming molds for many different applications.
Features:· Air cooled/ no water chillers· Closed loop temperature feedback· Operator safe - no hot spots or pinch points· Semi-automated· High and low force platforms· Easy front panel programming· Low friction pneumatic air cylinders and slides· Precise heat placement· Proprietary low mass mold design· Solid state circuitry· Temperature repeatable to + 1°C· CE marked
Benefits:· Compact footprint saves cleanroom space· Repeatability, high quality results· Easy to set up and validate· Quantifiable and validate-able process· High production first pass yields· Quick and easy tooling change
RF Generator 3220RF Generator with easy front panel programming.
Forming Platform 3226Featues standard insertion force and standard gripping force.
Forming Platform 3227Features low insertion force and standard gripping force.
Forming Platform 3228Features standard insertion force and high gripping force.
Applications:· Taper Tips· Radius Tips· Soft Tips· Closed End Tips· Dilator Tips· Flaring· Neck Downs
· Butt Welds· Overlap Welds· Braid to Non-Braid Welds· Single/Multilumen Applications· Balloon Tips and Welds· Marker Band Embedding/placement· Specializing in Custom Application
Vante PIRF II Catheter Manufacturing System
CATHETER MANUFACTURING
®
Mechanical Specifications
Dimensions
Operating Weight
Shipping Weight
Maximum Air Supply
No. of Slides
Slide Insertion Force
Grip Force Range
4 x 17.75 x 14"
(10 x 44.5 x 35.5 cm)
20 lbs (9.1 kg)
24 lbs (10.9 kg)
—
—
—
—
4 x 10 x 8"
(10.1 x 26.6 x 21.5 cm)
6 lbs (2.7 kg)
7 lbs (3.1 kg)
85 psi
Two (2) Slides
9.3 lbs @ 30 psi
18 lbs @ 90 psi - 4 lbs @ 20 psi
2.5 x 12 x 8.5"
(6 x 30.5 x 21.5 cm)
7 lbs (3.2 kg)
8 lbs (3.6 kg)
85 psi
Two (2) Slides
9.3 lbs @ 30 psi for 3226
3.2 lbs @ 30 psi for 3227
5 lbs @ 70 psi
CE
115 VAC 60 Hz
230 VAC 3A 50/60 Hz
100 VAC 50/60 Hz
90-150 Watts
40.68 MHz
3 AG F1/2 5A
5 x 20 mm T 6.3A @ 100V
5 x 20 mm T 5A @ 115V
5 x 20 mm T 3A @ 230V
—
—
—
—
—
—
—
—
—
—
—
—
Electrical Specifications
Certifications
Power Input
RF Power Output
Radio Frequency Output
Accessory Fuse
Main Fuses
IDEC® MicroSmart® HMI
1 Standard, 2 Optional
No
—
—
—
—
—
—
Performance Factors
User Interface
Process Parameters Storage
Internal Circuit Protection
Indoor use only
50 - 85°F (10 - 30°C)
Non-Condensing
II
2
Up to 2000 m
Indoor use only
50 - 85°F (10 - 30°C)
Non-Condensing
II
2
Up to 2000 m
Indoor use only
50 - 85°F (10 - 30°C)
Non-Condensing
II
2
Up to 2000 m
Operating Conditions
Use
Temperature
Humidity
Over-voltage Category
Pollution Degree
Altitude
3200 3226 / 3227 3228
CATHETER MANUFACTURING
PIRF II
vante.com | 877.565.5557520.881.6555 | Fax 520.326.0863