valvetrab-sq valvetrab sq - power/mation sq... exchangeable ... em a as s c r l e d s ta y arm rem...
TRANSCRIPT
Inhalt 9 kaliert7% Breite s
VALVETRAB SQ...
Exchangeable structure
Remote indication contact
Universal installation options
Pulse counter
Optical diagnostic and status indicator per phase
NEMA 1 / IP40 metal housing
NEMA 4X / IP66 housing available
Remote indication contact
Acoustic alarm
Optical diagnostic and status indicator per phase
Compact design
NEMA 4X / IP66 housing
VALVETRAB SQ SP
VALVETRAB SQ CC
VALVETRAB SQ SI
VALVETRAB SQ SE
VALVETRAB-SQ …
includes surge protection devices for American power supply systems. These have been specially designed for the American installation requirements.
offers complete protection against destructive surge voltages.
to the control cabinet or directly on electrical devices.
high discharge capacity of rated surge currents up to 200 kA per phase. The individual fuse for every protective path integrated in the design lends additional safety to the products.
approved as per the UL 1449 2nd edition 2007.
64 PHOENIX CONTACT
Surge protection for the NEMA power supply unitMain range & features
Max. surge current capacity
Status LEDs
Acoustic alarm
Remote indication contact
Pulse counter
Degree of protection
Short Circuit Current Rating (SCCR)
Filtering
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
Inhalt 9 kaliert7% Breite s
Comprehensive protection
Cascaded (stepped) use of VAL-SQ protective devices in building installation ensures effective protection of electrical systems.
VALVETRAB-SQ … The VALVETRAB-SQ product range
includes surge protection devices for American power supply systems. These have been specially designed for the American installation requirements.
Protection for all installation locations:– VAL-SQ SE (Service Entrance - for the
main supply)– VAL-SQ SP (Sub-Panel - for the sub-
distribution panels)– VAL-SQ CC (Control Cabinet - for the
control cabinet) – VAL-SQ SI (Small Installation - for the
equipment). The common use of protective devices
offers complete protection against destructive surge voltages.
Protective devices can be mounted next to the control cabinet or directly on electrical devices.
The devices have a protective circuit with high discharge capacity of rated surge currents up to 200 kA per phase. The individual fuse for every protective path integrated in the design lends additional safety to the products.
The entire product range has been approved as per the UL 1449 2nd edition 2007.
65PHOENIX CONTACT
Surge protection for the NEMA power supply unitMain range & features
Service Entrance Sub-Panel Control Cabinet
VAL-SQ SE VAL-SQ SP VAL-SQ CC
Features– The display with surge counter reflects
the number of power pulse currents discharged safely to ground.
– Acoustic status alarm of the protective device for the VAL-SQ SE and VAL-SQ SP products in the event of damage
– LEDs in all VAL-SQ products for continuous status monitoring of every phase
VAL-SQ SE VAL-SQ SP VAL-SQ CC VAL-SQ SI
Max. surge current capacity 120, 160 and 200 kA
120 kA 80 kA 40 kA 40 kA 25 kA
Status LEDs
Acoustic alarm - - -
Remote indication contact - - -
Pulse counter - - - - -
Degree of protection NEMA 1 / IP40 NEMA 4X / IP66 NEMA 1 / IP40 NEMA 1 / IP40 NEMA 4X / IP66 NEMA 4X / IP66
Short Circuit Current Rating (SCCR)
200 kA 200 kA 22 kA 22 kA 10, 25 and 200 kA 22 kA
Filtering -30 dB -30 dB -30 dB - -
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
Inhalt 9 kaliert7% Breite s
The selection matrix makes it easy to select suitable surge protection for the desired application.
VA
L-S
Q S
E Ideal protection for the main distributor
Multi-phase surge protection with remote indication contact, status LED, interference suppressor filter and pulse counter
VA
L-S
Q S
P Ideal protection for the sub-distribution panels
Multi-phase surge protection with remote indication contact and interference suppressor filter in a compact housing
VA
L-S
Q C
C
Adapted for the installation in the control cabinet
Multi-phase surge protection with interference suppressor filter in a compact housing
VA
L-S
Q S
I Ideal protection for small systems and equipment with limited space
Multi-phase surge protection with interference suppressor filter in a compact housing
Inst
allat
ion
loca
tion
Descr
iptio
n
66 PHOENIX CONTACT
Surge protection for the NEMA power supply unitSelection guide
Designation structure
VAL - SQ - SE 200 - 277/480Y
Product range
VALVETRAB
SQ
Range group
SE - Main supply
SP - Sub-distribution panels
CC - Control cabinet
SI - Equipment
Rated max. surge current
Voltage system / network type
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
Inhalt 9 kaliert7% Breite s
Multi-phase surge protection with remote indication contact, status LED, interference suppressor filter and
Multi-phase surge protection with remote indication contact and interference suppressor filter in a compact
Ideal protection for small systems and equipment with
2 1 200 kA
200 kA
68
2 1 160 kA 68
2 1 120 kA 68
2 4X 120 kA 200 kA 70
2 1 80 kA 22 kA 70
2 1 40 kA 22 kA 72
1, 2 4X 40 kA 22 kA 73
1, 2 4X 25 kA 10 kA 73
Max
. sur
ge cu
rren
t cap
acity
(8/2
0 µs)
UL type
NEM
A clas
s
SCCR
LED stat
us d
isplay
Acous
tic al
arm
Remot
e in
dica
tion
cont
act
Pulse
coun
ter
Groun
d co
nnec
tion
Filter
Page
67PHOENIX CONTACT
Surge protection for the NEMA power supply unitSelection guide
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 N GND
� �� � �
C NC NO L1 L2 L3 N GND C NC NO
� � �� � � �
Inhalt 9 kaliert7% Breite s
Description Reference Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
Service entrance surge protection for 120/240 split-phase
configuration
120 kA 1 VAL-SQ SE 120-120/240S/FM 2804021 1
160 kA 1 VAL-SQ SE 160-120/240S/FM 2804034 1
200 kA 1 VAL-SQ SE 200-120/240S/FM 2804047 1
Service entrance surge protection for 120/208 Wye configuration
120 kA 2 VAL-SQ SE 120-120/208Y/FM 2803917 1
160 kA 2 VAL-SQ SE 160-120/208Y/FM 2803920 1
200 kA 2 VAL-SQ SE 200-120/208Y/FM 2803933 1
Service entrance surge protection for 277/480 Wye configuration
120 kA 3 VAL-SQ SE 120-277/480Y/FM 2804076 1
160 kA 3 VAL-SQ SE 160-277/480Y/FM 2804089 1
200 kA 3 VAL-SQ SE 200-277/480Y/FM 2804092 1
Service entrance surge protection for 347/600 Wye configuration
120 kA 4 VAL-SQ SE 120-347/600Y/FM 2804115 1
160 kA 4 VAL-SQ SE 160-347/600Y/FM 2804128 1
200 kA 4 VAL-SQ SE 200-347/600Y/FM 2804131 1
Service entrance surge protection for 480 Delta configuration
120 kA 5
160 kA 5
200 kA 5
Service entrance surge protection for 600 Delta configuration
120 kA 6
160 kA 6
200 kA 6
Service entrance surge protection for 120/240 High-Leg Delta
configuration
120 kA 7
160 kA 7
200 kA 7
Technical data 1 2 3 4
MCOV V 150 V / - 150 V / - 320 V / - 420 V / -
Suppressed voltage rating (SVR)
L-N / L-G 500 V / 500 V 500 V / 500 V 900 V / 1200 V 1200 V / 1500 V
N-G / L-L 500 V / 800 V 500 V / 800 V 1200 V /
1800 V
1500 V / 2500 V
Short circuit current rating (SCCR) 200 kA 200 kA
UL type Type 2 Type 2
Degree of protection IP40 / NEMA 1 IP40 / NEMA 1
Error/status indicator Phase LEDs / Audible alarm / Remote indicator contact Phase LEDs / Audible alarm / Remote indicator contact
Temperature range -40°C ... 60°C -40°C ... 60°C
Dimensions W / H / D 381.00 mm / 356.00 mm / 99.00 mm 381.00 mm / 356.00 mm / 99.00 mm
Test standards UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45
68 PHOENIX CONTACT
VAL-SQ SE…-120/240S/FMArrester for 120/240 V single / split phase
VAL-SQ SE ... Y/FMArrester for 120/208 V, 277/480 V, 347/600 V Wye systems
The VAL-SQ SE… provides maximum surge protection for the service entrance. These units are available with 120, 160 and 200 kA surge current ratings to protect electronic equipment in industrial, medical and commercial applications.
The VAL-SQ SE… utilizes a hybrid suppression circuit, Sine Wave Tracking, in a single, replaceable module. It provides both transient protection and up to -30 dB of noise filtration. Each surge suppression mode is individually fused.Approvals starting on page 208.
Device protection for the service entrance
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 L3 N GND C NC NO
� � �� � � �
L1 L2 L3 N GND C NC NO
� � �� � � �
Inhalt 9 kaliert7% Breite s
Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
VAL-SQ SE 120 120/240S-R 2804348 1
VAL-SQ SE 160-120/240S-R 2804351 1
VAL-SQ SE 200-120/240S-R 2804364 1
VAL-SQ SE 120-120/208Y-R 2804173 1
VAL-SQ SE 160-120/208Y-R 2804225 1
VAL-SQ SE 200-120/208Y-R 2804270 1
VAL-SQ SE 120-277/480Y-R 2804199 1
VAL-SQ SE 160-277/480Y-R 2804241 1
VAL-SQ SE 200-277/480Y-R 2804296 1
VAL-SQ SE 120-347/600Y-R 2804209 1
VAL-SQ SE 160-347/600Y-R 2804254 1
VAL-SQ SE 200-347/600Y-R 2804306 1
VAL-SQ SE 120-480D/FM 2804144 1 VAL-SQ SE 120-480D-R 2804212 1
VAL-SQ SE 160-480D/FM 2804157 1 VAL-SQ SE 160-480D-R 2804267 1
VAL-SQ SE 200-480D/FM 2804160 1 VAL-SQ SE 200-480D-R 2804319 1
VAL-SQ SE 120-600D/FM 2804513 1 VAL-SQ SE 120-600D-R 2804539 1
VAL-SQ SE 160-600D/FM 2804520 1 VAL-SQ SE 160-600D-R 2804596 1
VAL-SQ SE 200-600D/FM 2804526 1 VAL-SQ SE 200-600D-R 2804552 1
VAL-SQ SE 120-120/240HLD/FM 2803969 1 VAL-SQ SE 120-120/240HLD-R 2804186 1
VAL-SQ SE 160-120/240HLD/FM 2803975 1 VAL-SQ SE 160-120/240HLD-R 2804238 1
VAL-SQ SE 200-120/240HLD/FM 2803988 1 VAL-SQ SE 200-120/240HLD-R 2804283 1
5 6 7
640 V / - 840 V / - 320 V / 150 V
- / - - / - 800 V / 900 V
- / 1800 V - / 2500 V 500 V / 800 V
200 kA 200 kA
Type 2 Type 2
IP40 / NEMA 1 IP40 / NEMA 1
Phase LEDs / Audible alarm / Remote indicator contact Phase LEDs / Audible alarm / Remote indicator contact
-40°C ... 60°C -40°C ... 60°C
381.00 mm / 356.00 mm / 99.00 mm 381.00 mm / 356.00 mm / 99.00 mm
UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45
69PHOENIX CONTACT
VAL-SQ SE ... D/FMArrester for 480 V, 600 V Delta systems
VAL-SQ SE ... HLD/FMArrester for 120/240-208 V High Leg Delta systems
VAL-SQ SE … -RReplacement modules for VAL-SQ SE... arresters
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 N GND
� �� � �
C NC NO L1 L2 L3 N GND C NC NO
� � �� � � �
Inhalt 9 kaliert7% Breite s
Description Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
Service panel surge protection for 120/240 single / split-phase
configuration
80 kA VAL-SQ SP 80-120/240S/FM 2804000 1
120 kA VAL-SQ SP 120-120/240S/FM 2804018 1
Service panel surge protection for 120/208 Wye configuration
80 kA VAL-SQ SP 80-120/208Y/FM 2803894 1
120 kA VAL-SQ SP 120-120/208Y/FM 2803904 1
Service panel surge protection for 277/480 Wye configuration
80 kA
120 kA
Service panel surge protection for 120/240 High-Leg Delta
configuration
80 kA
120 kA
Service panel surge protection for 347/600 Wye configuration
80 kA
Service panel surge protection for 600 Delta configuration
80 kA
Technical data ...80-120/240S/FM ...120-120/240S/FM ...80-120/208Y/FM ...120-120/208Y/FM
MCOV 150 V / - 150 V / - 150 V / - 150 V / -
Suppressed voltage rating (SVR)
L-N / L-G 400 V / 500 V 400 V / 400 V 400 V / 500 V 400 V / 400 V
N-G / L-L 400 V / 800 V 400 V / 800 V 400 V / 800 V 400 V / 800 V
Short circuit current rating (SCCR) 22 kA 200 kA 22 kA 200 kA
UL type Type 2 Type 2 Type 2 Type 2
Connection data
Power (AWG / length) 10 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm
Remote indicator contact #24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
Degree of protection IP40 / NEMA 1 IP40 / NEMA 1
Error/status indicator Phase LEDs / Audible alarm / Remote indicator contact Phase LEDs / Audible alarm / Remote indicator contact
Temperature range -40°C ... 60°C -40°C ... 60°C
Dimensions W / H / D 250.00 mm / 122.00 mm / 79.00 mm 250.00 mm / 122.00 mm / 79.00 mm
Test standards UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45
70 PHOENIX CONTACT
VAL-SQ SP …-120/240S/FMArrester for 120/240 V split / split phase
VAL-SQ SP…-120/208Y/FMArrester for 120/208 V Wye systems
The VAL-SQ SP… provides 80 or 120 kA of surge current rating per phase. The VAL-SQ SP… SPD allows protection to be installed adjacent to service panels or near sensitive equipment. The VAL-SQ SP… includes sine wave tracking circuitry that provides up to -30 dB of noise attenuation. Each surge suppression mode is individually fused.Approvals starting on page 208.
Device protection for the service panel
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 L3 N GND C NC NO
� � �� � � �
L1 L2 L3 N GND C NC NO
� � �� � � �
L1 L2 L3 N GND C NC NO
� � �� � � �
Inhalt 9 kaliert7% Breite s
Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
VAL-SQ SP 80-277/480Y/FM 2804050 1
VAL-SQ SP 120-277/480Y/FM 2804063 1
VAL-SQ SP 80-120/240HLD/FM 2803959 1
VAL-SQ SP 120-120/240HLD/FM 2803962 1
VAL-SQ SP 80-347/600Y/FM 2804102 1
VAL-SQ SP 80-600D/FM 2804500 1
...80-
277/480Y/FM
...120-
277/480Y/FM
...80-347/600Y/FM ...80-120/240HLD/FM ...120-120/240HLD/FM VAL-SQ SP 80-600D/FM
320 V / - 320 V / - 420 V / - 275 V / 150 V 275 V / 150 V 840 V / -
900 V / 900 V 800 V / 800 V 1200 V / 1200 V 700 V / 700 V 800 V / 800 V - / -
900 V / 1800 V 800 V / 1600 V 1200 V / 2500 V 500 V / 1300 V 400 V / 1500 V - / 2500 V
22 kA 200 kA 22 kA 22 kA 200 kA 200 kA
Type 2 Type 2 Type 2 Type 2 Type 2 Type 2
10 AWG / 61
cm
10 AWG / 61
cm
10 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm
#24
AWG/0.205
mm² wires
(61 cm long)
#24
AWG/0.205
mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires
(61 cm long)
#24 AWG/0.205 mm² wires (61 cm long)
IP40 / NEMA 1 IP40 / NEMA 1 IP40 / NEMA 1
Phase LEDs / Audible alarm / Remote indicator contact Phase LEDs / Audible alarm / Remote indicator contact Phase LEDs / Audible alarm / Remote indicator contact
-40°C ... 60°C -40°C ... 60°C -40°C ... 60°C
250.00 mm / 122.00 mm / 79.00 mm 250.00 mm / 122.00 mm / 79.00 mm 250.00 mm / 122.00 mm / 79.00 mm
UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45 IEEE C62.45
71PHOENIX CONTACT
VAL-SQ SP …Y/FMArrester for 277/480 V and 347/600 V Wye systems
VAL-SQ SP… 120/240HLD/FMArrester for 120/240-208 V High Leg Delta systems
VAL-SQ SP 80-600D/FMArrester for 600 V Delta systems
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 GND N
� � �
L1 L2 L3 GND N
� � � �
Inhalt 9 kaliert7% Breite s
Description Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
Component surge protection
120/240 V AC single/split phase,3-wire + Gnd VAL-SQ CC 40-120/240S 2803991 1
120/208 V AC Wye, 4-wire + Gnd VAL-SQ CC 40-120/208Y 2803881 1
Component surge protection
120 V, 2-phase with common GND-N
Component surge protection
120 V, 2-phase with separate GND-N
240 V, 2-phase with separate GND-N
Component surge protection
Up to 600 V, 3-phase with common GND-N
Technical data
MCOV 150 V / - 150 V / -
Suppressed voltage rating (SVR)
L-N / L-G 500 V / 800 V 500 V / 800 V
N-G / L-L 400 V / 800 V 400 V / 800 V
Short circuit current rating (SCCR) 22 kA 22 kA
UL type Type 2 Type 2
Connection data
Power (AWG / length) 10 AWG / 61 cm 10 AWG / 61 cm
Degree of protection IP40 / NEMA 1 IP40 / NEMA 1
Housing material Metal Metal
Error/status indicator Optical / - / - Optical / - / -
Temperature range -40°C ... 60°C -40°C ... 60°C
Dimensions W / H / D 190.00 mm / 108.00 mm / 63.00 mm 190.00 mm / 108.00 mm / 63.00 mm
Test standards UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45
72 PHOENIX CONTACT
VAL-SQ CC 40-120/240SArrester, 40 kA, for 120/240 V single / split phase
VAL-SQ CC 40-120/208YArrester, 40 kA, for 120/208 V Wye systems
The VAL-SQ CC is an economical method of protecting electronic equipment in light commercial, light industrial and residential environments. Hybrid suppressor circuit reduces leakage current end products -30 dB of noise filtration.
The VAL-SQ SI… provides surge protection in a compact, affordable package.Each surge suppression mode is individually fused.
Device protection for control cabinets and small installations
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
L1 L2 PE/N
� �
L1 L2 GND N
� � �
L1 L2 L3 PE/N
� � �
Inhalt 9 kaliert7% Breite s
Type Order No.Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.Type Order No.
Pcs. /
Pkt.
VAL-SQ SI 25-2C-120 2800003 1
VAL-SQ SI 40-2S-120 2800005 1
VAL-SQ SI 40-2S-240 2800006 1
VAL-SQ SI 40-3C-600 2800007 1
... 40-2S-120 ... 40-2S-240
120 V / - 120 V / - 240 V / - 600 V / -
500 V / - 500 V / - 900 V / - 1800 V / -
- / 900 V 800 V / - 900 V / - 2000 V / -
22 kA 25 kA 10 kA 200 kA
Type 1 & 2 Type 2 Type 2 Type 1 & 2
14 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm 10 AWG / 61 cm
IP66 / NEMA 4X IP66 / NEMA 4X IP66 / NEMA 4X
Non-metallic Non-metallic Non-metallic
Optical / - / - Optical / - / - Optical / - / -
-40°C ... 70°C -40°C ... 70°C -40°C ... 70°C
56.90 mm / 52.80 mm / 56.90 mm 76.20 mm / 69.30 mm / 91.40 mm 91.40 mm / 69.30 mm / 76.20 mm
UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 / UL 1449 2nd edition, February 2007 / UL 1283 / IEEE C62.41 /
IEEE C62.45 IEEE C62.45 IEEE C62.45
73PHOENIX CONTACT
VAL-SQ SI 25-2C-120Arrester, 25 kA, 2-phase
VAL-SQ SI 40-…Arrester, 40 kA, 2-phase
VAL-SQ SI 40-3C-600Arrester, 40 kA, 3-phase
Surge protection for the NEMA power supply unitSurge protection devices
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
v
Inhalt 9 kaliert7% Breite s
Network type Application
Split/Single-phase
120/240 V
Three-phase high-leg Delta
120/240-208 V
74 PHOENIX CONTACT
Surge protection for the NEMA power supply unitApplications
VAL-SQ SP
VAL-SQ SE
VAL-SQ SE VAL-SQ SI
VAL-SQ CCVAL-SQ SP
VAL-SQ SI VAL-SQ SI
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com
Inhalt 9 kaliert7% Breite s
Network type Application
Three-phase Delta
Three-phase Wye
120/208 V277/480 V347/600 V
75PHOENIX CONTACT
Surge protection for the NEMA power supply unitApplications
VAL-SQ SE VAL-SQ SP
VAL-SQ CCVAL-SQ SPVAL-SQ SE
VAL-SQ SI
VAL-SQ SI
Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108 [email protected] - 800-843-9859 - www.powermation.com