vacuum sensors & gauges · 2012. 1. 27. · vacuum level achievement. ... psf diaphragm switch...

5
Vacuum Sensors & Gauges Catalogue Edition 2

Upload: others

Post on 10-Oct-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vacuum Sensors & Gauges · 2012. 1. 27. · vacuum level achievement. ... PSF Diaphragm Switch Part Number PSF109S-NPT-81-330 • Controllable hysteresis • Field adjustable vacuum

 

 

Vacuum Sensors & Gauges

 

Catalogue Edition 2 

 

Page 2: Vacuum Sensors & Gauges · 2012. 1. 27. · vacuum level achievement. ... PSF Diaphragm Switch Part Number PSF109S-NPT-81-330 • Controllable hysteresis • Field adjustable vacuum

Vacuum Measurement

AP25 V 01 - F2 - QD

AP25 AP30 Media Non lubricated dry air or non corrosive gas Maximum Over Pressure 43.5psi(g) Electrical Connection M8 4 Pin male connector (analogue models – 6ft lead wire) Operating Voltage 12 – 24VDC ±10% Current Consumption ≤55mA Display 4 Digit 7 Segment Red LED ( Display Units kPa, MPa, kgf/cm², bar, psi, inHg, mmHg, mmH2O Repeatability ≤2% F.S ± 1 digit Hysteresis Adjustable Response Time ≤2.5ms (chatter proof selectable 24, 192 & 768ms) Indicator OUT1 = Green LED OUT2 = Red LED Analogue Output 1 to 5V ≤ ±5% F.S Linearity ≤ ±1% F.S Insulation IP65 IP40 Ambient Temp. 0-50ºC (32-122ºF) Vacuum / Pressure Port 1/8NPT Female Shock Resistance 980m/s (100G) 3 times in each direction X,Y & Z Weight 71g 35g

AP30 Series AP25 Series

Series 25 30

Type C - Compound P - Pressure V - Vacuum

Output 01 – 2 x NPN + 1 x Analogue02 – 2 x NPN 03 – 2 x PNP + 1 x Analogue04 – 2 x PNP

The AP25 and AP30 are the same fundamental switch with regards to performance and selection criteria. They only differ in physical form and size. Available in the following configurations.

• COMPOUND 29.9”Hg - +14.7psi(g) • PRESSURE -14.7psi(g) - 150psi(g) • VACUUM 0 - 29”Hg (0 - ¯101.3KPa)

(01) NPN + ANALOGUE (02) NPN (03) PNP + ANALOGUE (04) PNP

AP30 Series AP25 Series

All dimensions are mm

shown with 6ft lead wire

shown with male M8 4 pin connector

C8-I-F-4A-5M 15ft Straight Connector C8-L-F-4A-5M 15ft 90º Connector

M8 Male – non analogue only

M8 Connectors for QD Models

Page 105 Edition 2 www.vacuforce.com | 1.866.280.3766

Page 3: Vacuum Sensors & Gauges · 2012. 1. 27. · vacuum level achievement. ... PSF Diaphragm Switch Part Number PSF109S-NPT-81-330 • Controllable hysteresis • Field adjustable vacuum

Vacuum Measurement

Model VAS04 VAS06N Adjustment Range 4.5 – 12”Hg Accuracy 1.5”Hg Hysteresis 3”Hg Electrical Rating AC125V – 5A Vacuum Connection 5/32” (4mm) 1/4"

The VAS vacuum switch is a simple mechanical indicator of vacuum level achievement. Fully adjustable with a simple push to connect fitting for vacuum connection, the VAS switch is ideal for most part presence applications.

 

 

 

 

 

 

1/4NPT Stem Mount SEC-201L-254A

1/4NPT Back Mount SEC-202L-254A

1/4NPT Panel Mount SEC-203L-254A

2.5” Dial Stainless Steel Case Liquid Filled

Carbon Steel Gauges 1.5” & 2.0” Dial

Dial Ø Port Position Port Size GS-011.5030HGCSBA18 1.5” Centre Back 1/8NPT GS-011.5030HGCSBO18 Stem Mount GS-012.0030HGCSBA14 2.0” Centre Back 1/4NPT GS-012.0030HGCSBO14 Stem Mount

All dimensions are mm

All dimensions are mm

Page 106 Edition 2 www.vacuforce.com | 1.866.280.3766

Page 4: Vacuum Sensors & Gauges · 2012. 1. 27. · vacuum level achievement. ... PSF Diaphragm Switch Part Number PSF109S-NPT-81-330 • Controllable hysteresis • Field adjustable vacuum

PSF Diaphragm Switch Part Number PSF109S-NPT-81-330

• Controllable hysteresis • Field adjustable vacuum set point, 5.9” to 24.25”Hg • Snap action basic switch, up to 15A*, 125/250 VAC • 1/8” NPT male vacuum connection • Small size, lightweight • Dependable long life (10+ million cycles)

MECHANICAL

Standard Tolerance ±20% Switch Type SPDT Normally Open or Normally Closed Switching Medium Air; compatible fluids Mechanical Life More than 10 million cycles Operating Temp. +40°F to +150°F (standard) PHYSICAL

Case Material Polycarbonate (optional: Lexan 141, Supec®, Ultem®, Noryl®) Vacuum Port Options .250” diameter, 1/8” NPT, Quick Connect Fitting Port Diaphragm Material Polyurethane (Teflon® optional) Contact Points Silver (Gold available on special order) Electrical Connections Terminals – .187”x.020” tab-type for use with quick Mounting #2 Screws through eyelets; Weight Less <20g ELECTRICAL

Current Rating – 15A

Operating Voltage 24VDC through 230VAC

Page 107 Edition 2 www.vacuforce.com | 1.866.280.3766

Page 5: Vacuum Sensors & Gauges · 2012. 1. 27. · vacuum level achievement. ... PSF Diaphragm Switch Part Number PSF109S-NPT-81-330 • Controllable hysteresis • Field adjustable vacuum

OEM Economy Vacuum SwitchThe LF20 vacuum and pressure switch has been developed to offer typical set points. Two standard models are available for vacuum in both a normally open and normally closed configuration. As standard they are supplied with a rubber boot to offer insulation of IP65. Other pressure and vacuum settings available. Please enquire.

This switch is compatible with air, water, hydraulic fluid, motor oils and refrigerants. Features include:

• Automatic reset • Factory calibrated set points • Rugged construction

Part Number Switch Point Type Rubber Boot Port Size LF20-V-31111B-15"HG 15"Hg NC Included 1/8NPT

LF20-V-32111B-15"HG 15"Hg NO Included 1/8NPT

Media Air, Water, motor oils, transmission oils, refrigeration fluid etc Working Pressure <150psi(g) Burst Pressure 500 psi(g) Operating Temperature Range -40ºF to +176ºF (-40ºC to +80ºC) Switch Type Direct action, blade contact Electrical Rating 120/240VAC, 375VA

120VVAC, 5.8FLA-34.8LRA 240VAC 2.9FLA-15LRA 24VAC/DC, 3A

Dielectric Strength 750 VRMS across open contacts 1550 VRMS terminal to fitting

Terminals 1/4" Spade Connection Connection 1/8NPT (other connection types available, please enquire)

This adjustable pneumatic vacuum switch is used on applications where the device requires a compressed air signal when a specific vacuum level is met. Normally open (NO) and normally closed (NC) models are available depending on the specifics of the intended use.

Pneumatic Vacuum Switch

Model AVS-212 AVS-213 Switch Function NC (normally closed) NO (normally open)

Signal Pressure Range 22.5-120psi(g) / 1.5-8bar(g) Hysteresis 3.6”Hg / 120mbar(a) 0.9”Hg / 30mbar(a)

Temperature Range 14ºF - 140ºF / -10ºC - +60 ºC Weight 1.5oz / 44g

Vacuum Connection NPSF1/8 / G1/8

AVS-212 NC

AVS-213 NO

Page 108 Edition 2 www.vacuforce.com | 1.866.280.3766