vacant property boarding · many types of adhesive bonding, welding and mechanical fastening...

29
Vacant Properties Clear Boarding with SecureView™

Upload: others

Post on 27-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Vacant Properties Clear

Boarding with SecureView™

Page 2: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 1 | P a g e

TABLE OF CONTENTS

Product Data Sheet… pages 2 & 3

Cleaning & Graffiti Removal… page 4

Window Installation Guide…pages 5 through 23

Return Policy…page 24

Door Installation Guide…page 25 & 26

Q & A…page 27 & 28

Page 3: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 2 | P a g e

SecureView™ Product Data Sheet

Description:

SecureView™ is an industrial grade sheet material extruded from post-industrial grade recycled polycarbonate

regrind/resins. The material is an excellent candidate for a wide range of flat or vacuum formed applications. It

can also be used for non-aesthetic applications requiring impact resistance, good heat resistance, and

formability.

Typical Property Values*

Property Test Method Unit Value

Physical

Specific Gravity, color dependent ASTM D792 -- 1.20

Mechanical

Tensile Strength, Yield ASTM D638 psi 8,000

Tensile Modulus ASTM D638 psi 310,000

Flexural Strength, Yield ASTM D790 psi 12,500

Flexural Modulus ASTM D790 psi 310,000

Elongation , Break ASTM D638 % 70

Impact Strength Dynatup Ft-lbs

75°F (1/2" diameter dart) 75

-20°F 50

Izod Impact Strength ASTM D256A Ft-lbs

Unnotched @ 75°F No break

Unnotched @ -20°F No break

Water Absorption @ 24 hr immersion equilibrium ASTM D570 % .35

Thermal

Coefficient of Thermal Expansion ASTM D696 in/in/°F 3.75 x 10-5

Heat Deflection Temperature ASTM D648 °F

@ 264 psi 270

@ 66 psi 280

Mold Shrinkage in/in .007-.009

*These typical values are not intended for specification purposes. If minimum certifiable properties are

required please contact your SecureView™ representative.

Page 4: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 3 | P a g e

Processing

SecureView™ sheets can be used for thermoforming. It offers high, deep draw ratios, equal wall thickness

distribution, and it can be formed into complex shapes using standard thermoforming equipment. Sandwich

type heating systems give the best results. SecureView™ sheets have a forming temperature range of 350–

400°F. When forming, a draft angle of at least 3° should be allowed, and post mold shrinkage of .007–.009 in/in

taken into account.

Pre-drying

It is important to ensure that SecureView™ sheets are free of moisture prior to thermoforming. A hot air

circulating oven set at 250°F is recommended. Pre-drying times vary from 3–24 hours, depending on sheet

thickness.

Assembling

Parts made from SecureView™ sheets can be assembled with plastics, metals, rubber and other materials using

many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials

can cause environmental stress cracking, please consult SecureView, for advice on specific applications

Painting

SecureView™ is well-suited for use with a wide variety of modern decoration techniques. A list of approved

paint systems and suppliers is available upon request.

Chemical Resistance

SecureView™ has sufficient resistance to most mineral oils, greases, aliphatic hydrocarbons and acids under low

or moderate stress levels. Specific (application related) testing is always advised, especially in applications

where the sheets will come into contact with aggressive chemicals.

Product Availability Check availability. Not all sizes always available at all locations.

Product sizes: 4’x8’, 5’x8’, 6’x8’ sheets

Textures/Masking: Polished/Polished, poly cling masking

Colors Standard: Clear

For industrial, non-aesthetic applications. There are no quality specifications associated with this product.

swylen
Typewritten text
Page 5: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 4 | P a g e

SecureView™ Cleaning Recommendations & Graffiti Removal The following cleaning recommendations apply to all SecureView™ products. Periodic cleaning using correct procedures

can help to prolong service life. For cleaning, it is recommended that the following instructions be adhered to:

Cleaning Procedure for Small Areas:

1. Gently wash sheet with a solution of mild soap and lukewarm water, using a soft, grid-free cloth or sponge to loosen

any dirt or grime.

2. Fresh paint splashes, grease and smeared glazing compounds can be removed easily before drying by rubbing lightly

with a soft cloth using petroleum ether (BP65), hexane or heptane. Afterwards, wash the sheet using mild soap and

lukewarm water.

3. Scratches and minor abrasions can be minimized by using a mild automobile polish. We suggest that a test be made on

a small area of SecureView with the polish selected and that the polish manufacturer’s instructions be followed, prior to

using the polish on the entire sheet.

4. Finally, thoroughly rinse with clean water to remove any cleaner residue and dry the surface with a soft cloth to

prevent water spotting.

Cleaning Procedure for Large Areas:

1. Clean the surface using a high-pressure water cleaner (max. 100bar or 1,450psi) and/or a steam cleaner. We suggest

that a test be made on a small area, prior to cleaning the entire sheet.

2. Use of additives to the water and/or steam should be avoided.

Other Important Instructions:

• Never use abrasive or highly alkaline cleaner on SecureView™ polycarbonate materials.

• Never use aromatic or halogenated solvents like toluene, benzene, gasoline, acetone or carbon tetrachloride on

SecureView™ polycarbonate materials.

• Use of incompatible cleaning materials with SecureView™ can cause structural and/or surface damage.

• Contact with harsh solvents such as methyl ethyl ketone (MEK) or hydrochloric acid can result in surface

degradation and possible crazing of the SecureView polycarbonate sheet.

• Never scrub with brushes, steel wool or other abrasive materials.

• Never use squeegees, razorblades or other sharp instruments to remove deposits or spots.

• Do not clean SecureView™ polycarbonate sheets in direct sunlight or at high temperatures as this can lead to

staining.

• For all mentioned chemicals consult the manufacturer’s material safety datasheet (MSDS) for proper safety

precautions.

Graffiti Removal for SecureView™:

Use butyl cellosolve with a clean, soft cloth to remove paints, marking pen inks and lipstick. Afterwards, wash the sheet

using mild soap and lukewarm water, then rinse with clean water to remove residue and dry with a soft cloth.

Masking tape and adhesive tape work well for lifting off old, weathered paints.

To remove labels stickers, the use of kerosene or petroleum ether (BP65) is generally effective. If the solvent does not

penetrate the sticker material, apply heat using a hair dryer to soften the adhesive and promote removal. Afterwards the

cleaning procedure for small areas as outlined above should be followed.

Page 6: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 5 | P a g e

WINDOW COVER INSTALLATION SINGLE HUNG WINDOW

1. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ Security screws (Minimum 2” length.)

2. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, one crossbar shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure up from the window sill and down from the top panel location. Transfer these measurements to the SecureView™ panel and drill two (2) ½’ holes.

☐ Drill and countersink holes around the upper perimeter of the SecureView™ panel for require security screws. Start with a hole at each of the top

corners and continue adding holes at 10” to 12” increments across the top and down the two sides to approximately half way down the panel.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

3. INSTALL

☐ Remove window sash or slide the lower sash to the center of the window frame so that two (2) bolts can be placed near the lower corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Place a security screw through each of the perimeter holes to fasten the panel into the window frame or exterior casing.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 7: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 6 | P a g e

WINDOW COVER INSTALLATION SINGLE HUNG WINDOW (TALL)

4. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ Security screws (Minimum 2” length.)

5. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, one crossbar shall be used per window.

☐ Locate the carriage bolt positions so that the bolts will be close to the existing window frame. The bolts should be placed no more than 3/4” from the

window frame at the width and no more than 6” from the window sill. Additional bolts shall be located at the vertical middle of the window or just

below the window sash when it is pushed to its upper position. Transfer these measurements to the SecureView™ panel and drill four 1/2” holes.

☐ Drill and countersink holes around the upper perimeter of the SecureView™ panel for require security screws. Start with a hole at each of the top

corners and continue adding holes at 10” to 12” increments across the top and down the two sides to approximately half way down the panel.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

6. INSTALL

☐ Remove window sash or slide the lower sash to its upper position of the window frame so that four (4) carriage bolts can be placed near the four corners of the

window opening..

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Place a security screw through each of the perimeter holes to fasten the panel into the window frame or exterior casing.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 8: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 7 | P a g e

WINDOW COVER INSTALLATION SINGLE HUNG WINDOW (GLASS PANES BROKEN OR REMOVED)

7. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ Security screws (Minimum 2” length.)

8. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, one crossbar shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure up from the window sill and down from the top panel location. Transfer these measurements to the SecureView™ panel and drill two (2) ½’ holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

9. INSTALL

☐ Make sure the upper sash and lower sash are in place and lock the window. Remove any remaining glass so that four (4) bolts can be placed near the

four corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 9: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 8 | P a g e

WINDOW COVER INSTALLATION DOUBLE HUNG WINDOW

10. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

11. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, a minimum of two (2) crossbars shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure up from the window sill and down from the top panel location. Transfer these measurements to the SecureView™ panel and drill four (4) ½’ holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

12. INSTALL

☐ Remove window sash or slide the sashes to the center of the window frame so that four (4) bolts can be placed near the four corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper

location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 10: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 9 | P a g e

WINDOW COVER INSTALLATION DOUBLE HUNG WINDOW (TALL)

13. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ One (1) additional cross brace.

14. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, three (3) or more crossbars shall be used per window.

☐ Locate the carriage bolt positions so that the bolts will be close to the existing window frame. The bolts should be placed no more than 3/4” from the

window frame at the width and no more than 6” from the window sill and top frame. Additional bolts shall be located at the vertical middle of the window

or just below the window sashes when they are pushed up against the top bolts. Transfer these measurements to the SecureView™ panel and drill six (6) or

more 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

15. INSTALL

☐ Remove window sash or slide the sashes to the center of the window frame so that four (4) bolts can be placed near the four corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 11: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 10 | P a g e

WINDOW COVER INSTALLATION DOUBLE HUNG WINDOW (GLASS PANES BROKEN/REMOVED)

16. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

17. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, a minimum of two (2) crossbars shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure up from the window sill and down from the top panel location. Transfer these

measurements to the SecureView™ panel and drill four (4) ½” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

18. INSTALL

☐ Make sure upper sash and lower sash are in place and lock the window. Remove any remaining glass so that four (4) bolts can be placed near the four

corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 12: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 11 | P a g e

WINDOW COVER INSTALLATION DOUBLE HUNG WINDOW (UPPER SASH INOPERABLE)

19. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ Security screws (Minimum 2” length.)

20. MEASURE AND CUT

☐ Measure window opening (width and height.) This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be place behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, a minimum of one (1) crossbars shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure from the window sill and down from the top panel location. Transfer these measurements

to the SecureView™ panel and drill two 1/2” holes.

☐ Drill and countersink holes around the upper perimeter of the SecureView™ panel for required security screws. Start with a hole at each of the top corners and

continue adding holes at 10”- 12” increments across the top and down the two sides to approximately half way down the panel.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

21. INSTALL

☐ Remove window sash or slide the lower sash to the center window frame so that two (2) bolts can be placed near the lower corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Place the required security screw through each of the perimeter holes to fasten the panel into the window frame or exterior casing.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 13: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 12 | P a g e

WINDOW COVER INSTALLATION CASEMENT WINDOWS

22. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

23. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™

panel, when cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window

casing. Cut the crossbar material. Under this scenario, two (2) or more crossbars shall be used per window.

☐ Locate the carriage bolt positions so that the bolts will be close to the existing window frame. The bolts should be placed no more than 3/4” from

the window frame at the width and no more than 6” from the window sill and top frame. Transfer these measurements to the SecureView™

panel and drill four (4) 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

24. INSTALL

☐ Remove window sash.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper

location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 14: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 13 | P a g e

WINDOW COVER INSTALLATION CASEMENT WINDOWS (TALL)

25. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

☐ One additional cross brace.

26. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when cut,

will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window

casing. Cut the crossbar material. Under this scenario, three (3) crossbars shall be used per window.

☐ Locate the carriage bolt positions so that the bolts will be close to the existing window frame. The bolts should be placed no more than 3/4”

from the window frame at the width and no more than 6” from the window sill and top frame. Additional bolts shall be located at the vertical

middle of the window. Transfer these measurements to the SecureView™ panel and drill six (6) 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

27. INSTALL

☐ Remove window sash.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper

location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 15: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 14 | P a g e

WINDOW COVER INSTALLATION CASEMENT WINDOWS (GLASS PANE BROKEN/REMOVED)

28. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth.)

☐ Washers.

☐ Nuts.

29. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing. Cut

the crossbar material. Under this scenario, two (2) or more crossbars shall be used per window.

☐ Locate the carriage bolt positions so that the bolts will be close to the existing window frame. The bolts should be placed no more than 3/4” from the

window frame at the width and no more than 6” from the window sill and top frame. Transfer these measurements to the SecureView™ panel and drill

four (4) 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

30. INSTALL

☐ Remove window sash or remove any remaining glass so that four (4) bolts can be placed near the 4 corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one (1) nut onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another security nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO (2) nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 16: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 15 | P a g e

WINDOW COVER INSTALLATION FIXED WINDOW

31. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ Security screws (Minimum 2” length.)

32. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when

cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Drill and countersink holes around the perimeter of the SecureView™ panel for required security screws. Start with a hole at each of the four corners and

continue adding holes at 10”-12” increments around the panel.

33. INSTALL

☐ Set the SecureView™ panel on the window sill and position the panel into its proper location.

☐ Place a security screw through each of the perimeter holes to fasten the panel into the window frame or exterior casing.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 17: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 16 | P a g e

WINDOW COVER INSTALLATION FIXED WINDOW (GLASS PANE BROKEN/REMOVED)

34. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth)

☐ Washers

☐ Nuts

35. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of window from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing.

Cut the crossbar material. Under this scenario, two (2) or more crossbars shall be used per window.

☐ Measure the clear window opening width and subtract 1”. Measure up from the window sill and down from the top panel location. Transfer these

measurements to the SecureView™ panel and drill four (4) 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

36. INSTALL

☐ Remove the window sash or remove any remaining glass so that four (4) bolts can be placed near the 4 corners.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one nut and washer onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 18: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 17 | P a g e

WINDOW COVER INSTALLATION BASEMENT WINDOW – SASH INOPERABLE

37. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ Security screws (Minimum 2” length.)

38. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when

cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Drill and countersink holes around the perimeter of the SecureView™ panel for required security screws. Start with a hole at each of the four corners and

continue adding holes at 10”-12” increments around the panel.

39. INSTALL

☐ Set the SecureView™ panel on the window sill and position the panel into its proper location.

☐ Place a security screw through each of the perimeter holes to fasten the panel into the window frame. If the window frame is deteriorated, then a

longer screw must be used.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 19: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 18 | P a g e

WINDOW COVER INSTALLATION BASEMENT WINDOW SASH REMOVABLE

40. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth)

☐ Washers

☐ Nuts

41. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel,

when cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure the interior of the window frame vertically and horizontally. Decide which direction the crossbar will be placed such that it will extend a

minimum of 3” beyond each side of the window frame. Cut the crossbar material. Under this scenario, two (2) or more crossbars shall be used per

window.

☐ Measure the clear window opening width and height and subtract 1”. Transfer these measurements to the SecureView™ panel and

drill four (4) 1/2” holes.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

42. INSTALL

☐ Remove the window sash.

☐ Place a 3/8” carriage bolt through each of the holes in the SecureView™ panel, set the panel on the window sill and position the panel into its proper location.

☐ Screw one nut and washer onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 20: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 19 | P a g e

WINDOW COVER INSTALLATION SLIDING GLASS DOOR

43. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ Security screws (Minimum 2” length.)

44. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when

cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Drill and countersink holes around the perimeter of the SecureView™ panel for required security screws into either the door frame or the door panels. Start

with a hole at each of the corners and continue adding holes at 10”-12” increments around the door.

☐ Drill and countersink a couple more holes down the center of the SecureView™ panel for security screws into the center door panel frame.

45. INSTALL

☐ Place a security screw through each of the perimeter holes to fasten the panel in place.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 21: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 20 | P a g e

WINDOW COVER INSTALLATION SLIDING GLASS DOOR – FIXED PANEL GLASS BROKEN/REMOVED

46. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth)

☐ Washers

☐ Nuts

47. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when

cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of door from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing. Cut

the crossbar material. Four (4) crossbars shall be used per door.

☐ Measure the door panel openings, measure up from the door sill and down from the top panel location to locate the carriage bolts 1/2” inside of frame of

the fixed panel corners and between the slider door panel and the frame. Transfer these measurements to the SecureView™ panel and drill six (6) six 1/2”

holes.

☐ Drill six (6) more 1/2“ holes in the SecureView™ panel evenly spaced vertically such that two crossbars may be located between the top and bottom crossbars

at the top and bottom of the door opening.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

48. INSTALL

☐ Remove any remaining glass from the fixed door panel so that carriage bolts can be placed through the door frame.

☐ Open the slider door panel enough to run carriage bolts between the door and frame.

☐ Place a 3/8” carriage bolt through each of holes in the SecureView™ panel, set the panel on the door sill and position the panel into its proper location.

☐ Screw one nut and washer onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 22: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 21 | P a g e

WINDOW COVER INSTALLATION SLIDING GLASS DOOR – SLIDER GLASS BROKEN/REMOVED

49. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth)

☐ Washers

☐ Nuts

☐ Security Screws (Minimum 2” length)

50. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when cut,

will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of door from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing. Cut the

crossbar material. Four (4) crossbars shall be used per door.

☐ Measure the door panel openings, measure up from the door sill and down from the top panel location to locate the carriage bolts 1/2” inside of frame of

the fixed panel corners and between the slider door panel and the frame. Transfer these measurements to the SecureView™ panel and drill six (6) 1/2”

holes.

☐ Drill six (6) more 1/2“ holes in the SecureView™ panel evenly spaced vertically such that two crossbars may be located between the top and bottom crossbars

at the top and bottom of the door opening.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

☐ Drill and countersink holes around the perimeter of the SecureView™ panel for required security screws into either the door frame or the door panel. Start

with a hole at each of the corners and continue adding holes at 10”-12” increments around the panel.

51. INSTALL

☐ Remove any remaining glass from the fixed door panel so that carriage bolts can be placed through the door frame.

☐ Place a 3/8” carriage bolt through each of holes in the SecureView™ panel, set the panel on the door sill and position the panel into its proper location.

☐ Screw one nut and washer onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 23: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 22 | P a g e

WINDOW COVER INSTALLATION SLIDING GLASS DOOR – BOTH GLASS BROKEN/REMOVED

52. TOOLS AND HARDWARE REQUIREMENTS

☐ 120 VAC circular saw with a high tooth count blade (carbide recommended)

☐ 3/8” carriage bolts (Length determined per window depth)

☐ Washers

☐ Nuts

53. MEASURE AND CUT

☐ Measure window opening (width and height). This will be inside of brick or inside of the window casing/brickmould such that the SecureView™ panel, when

cut, will fit snuggly and not permit a tool to be placed behind the panel.

☐ Cut the SecureView™ panel using a circular saw with a high touch count blade.

☐ Measure interior casing of door from outer edge of casing to the other so that the crossbar will rest squarely on the full face of the window casing. Cut the

crossbar material. Four (4) crossbars shall be used per door.

☐ Measure the door panel openings, measure up from the door sill and down from the top panel location to locate the carriage bolts 1/2” inside of frame of

the fixed panel corners and between the slider door panel and the frame. Transfer these measurements to the SecureView™ panel and drill six (6) 1/2”

holes.

☐ Drill six (6) more 1/2“ holes in the SecureView™ panel evenly spaced vertically such that two (2) crossbars may be located between the top and bottom

crossbars at the top and bottom of the door opening.

☐ Drill 7/16” holes through the crossbars to match the pattern in the SecureView™ panels.

54. INSTALL

☐ Remove any remaining glass from the fixed door panel so that carriage bolts can be placed through the door frame.

☐ Place a 3/8” carriage bolt through each of holes in the SecureView™ panel, set the panel on the door sill and position the panel into its proper location.

☐ Screw one nut and washer onto each of the carriage bolts.

☐ Place the crossbars onto the bolts and screw another nut on each of the carriage bolts.

☐ Tighten the outer nut, by hand, until the SecureView™ panel is squeezed into a compression fit.

☐ Tighten the inside nut against the crossbar and torque the outer nut with a ratchet or other tool so that no person can loosen them by hand.

☐ Use of TWO nuts and washers at each carriage bolt is a requirement for the integrity of the system.

☐ Please be sure not to over-tighten the bolts as warping of bracing bar and cover may occur.

Page 24: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 23 | P a g e

WINDOW COVER INSTALLATION SPECIAL CIRCUMSTANCES EXTERIOR

55. STORM WINDOWS

☐ Removal of the entire storm window shall allow for a standard installation.

☐ Removal of the storm window sashes will allow for security screws to be placed into the storm window frame. Cut the SecureView™ panel to either have

minimal or no overhang of the window frame to minimize the likely prying of the panel from the frame. Drill and countersink holes around the perimeter of the

SecureView™ panel for security screws. Start with a hole at each of the four corners and continue adding holes at 10”-12” increments around the panel.

☐ Keep the storm window sashes in place and cut the SecureView™ panel large enough that the perimeter of the panel may be screwed to the exterior window

casing such that the panel will be tight against the structure. Drill and countersink holes around the perimeter of the SecureView™ panel for security screws.

Start with a hole at each of the four corners and continue adding holes at 10”-12” increments around the panel.

☐ Do not install the SecureView™ panel so that the screws are exposed between the panel and the structure allowing the screws to be easily cut or pried from the

structure.

56. FLUSH MOUNTED WINDOWS

☐ This style of window does not permit the standard installation of the SecureView™ panel into a natural recess of the window which may not allow for the

SecureView™ panel to rest upon a window sill or other ledge. Below are a few ideas that could be employed in no particular order.

☐ Cut the SecureView™ panel to match the window frame and utilize the carriage bolt/compression method, but also add security screws into the window frame.

Drill and countersink holes around the perimeter of the SecureView™ panel for security screws. Start with a hole at each of the four corners and continue adding

holes at 10”-12” increments around the panel. This installation method will minimize the possible damage to the property.

☐ Cut the SecureView™ panel to extend evenly beyond the window frame allowing for security screws to be placed structure. Drill and countersink holes around the

perimeter of the SecureView™ panel for security screws. Start with a hole at each of the four corners and continue adding holes at 10”-12” increments around

the panel.

57. WINDOW AND FRAME REMOVED AND EXTRA LARGE PICTURE WINDOW

☐ Using 2x4s or other materials, build a frame that will create a recess for mounting of the SecureView™ panel. Cut the SecureView™ panel to match the window

frame and utilize the carriage bolt/compression method.

☐ Using 2x4s or other materials, build a frame that will create a recess for mounting of the SecureView™ panel. Cut the SecureView™ panel to match the window

frame and add security screws into the new window frame. Drill and countersink holes around the perimeter of the SecureView™ panel for security screws. Start

with a hole at each of the four corners and continue adding holes at 10”-12” increments around the panel.

☐ Cut the SecureView™ panel to extend evenly beyond the opening in the structure allowing for security screws to be placed into the structure. Drill and

countersink holes around the perimeter of the SecureView™ panel for security screws. Start with a hole at each of the four corners and continue adding holes at

10”-12” increments around the panel.

☐ Extra large picture window - If a SecureView™ panel is to be place against the window sash, the window glass is not separated from the panel. In the event this

occurs cut a piece of crossbar material so that it will span from the top of the window to the bottom resting on the face of the sash. Place the material vertically

at the center of the picture window and install the SecureView™ panel over this material. The panel is flexible enough that it will wrap around vertical member.

It will however require longer screws near the center of the panel.

Page 25: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 24 | P a g e

SECUREVIEW™, LLC (“SECUREVIEW™”) RETURN POLICY

Congratulations on your purchase of a new “SecureView™” product. We have gone the extra mile to provide detailed product

descriptions, photos, and videos of our products. In all cases, it is the customer’s responsibility to inspect the product prior to taking

delivery. With this in mind, please understand that we DO NOT accept returned products UNLESS they are damaged in transit or

defective, or we accidentally sent the wrong product.

Under the foregoing circumstances, we will gladly exchange your product free of charge in accordance with the following Return

Policy.

1. This policy applies only if we accidentally send you the wrong product, or if the product is damaged in transit, or defective.

2. This policy does not cover conditions resulting from abusive handling, misuse, or neglect, including: (a) exposure to water

or outdoor elements; (b) improper assembly; or (c) failure to follow product safety, use, or storage guidelines.

3. As your sole remedy, this policy allows you to return goods that you have purchased, in exchange for a replacement product.

4. To arrange for a return or refund please contact us at 1.855. SCRVIEW, or send us an e-mail at

[email protected]. Returns will be accepted under this policy only if requested within 14 days from

date of receipt.

5. We will generally respond to any return request within 48 hours of receipt. We will review any return request and, upon

accepting your return, will make the necessary arrangements to pick up the defective package at no extra cost to you. We

will schedule a convenient pick-up time for you. Once onsite, a courier or delivery company specified by SecureView™ will

arrive and print a customer receipt and free shipping label to complete the return. Please note: We will only incur the cost

of ONE pickup attempt.

6. Returned items must be in new condition with their original packaging. We will not ship any replacement items until the

original product is returned. We can only accept the return of opened items if they are damaged or defective.

7. Then, upon receiving the defective shipment, we will send out the corrected shipment free of charge. We will also send an

email confirmation upon shipping the new product complete with a new tracking number.

8. This return policy was last updated on March, 2013. We may update this policy from time to time as our business continues

to evolve and change, in which case the updated policy will apply to all products shipped after the date that such update takes

effect.

If for some reason our products do not meet your expectations, PLEASE LET US KNOW. We will do our best to ensure that you remain

a satisfied customer. Any input on how we can improve our products or customer service to better serve our valued customers is

greatly appreciated.

All products are sold “as is.” There are no warranties, including without limitation implied Warranties of merchantability, fitness

for any particular purpose, or non-infringement, which warranties are hereby specifically excluded. Remedies under this policy

are limited to the exchange and delivery of a replacement product, as outlined above. Under no circumstances will

SecureView™ be responsible for damages in excess of the purchase price. Additionally, incidental, special, punitive, or

consequential damages (including, but not limited to, lost profits) are in all cases hereby expressly excluded.

SecureView™ is manufactured using recycled materials, therefore product may exhibit minor cosmetic blemishes.

Page 26: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 25 | P a g e

DOOR INSTALLATION EXTERIOR

TOOLS AND HARDWARE REQUIREMENTS

MEASURE AND CUT

☐ Measure the door frame height that the SecureView™ Door System will be placed.

☐ Cut the door panel to height. Remove an equal amount from the top as from the

bottom of the Door System. Cut the Door System using a circular saw with a high

tooth count blade.

☐ Cut the Door System to width. Allow a minimum 1” of material to extend beyond the

hasp eyelets.

INSTALL

☐ Locate the three (3) positions for mounting the lock hasps. Place one (1) near the midpointvertical and the others approximately 9” from the top and bottom. Use the supplied lag screws

to anchor the hasp into the structure. Each hasp requires the use of three (3) screws for proper installation.

☐ a) A pilot hole must be drilled for each lag screw 7/32” for

hardwood or 3/16” for soft wood.

☐ b) Eyelet shoulder must be located such that it is flush with the

door frame to ensure the Door System closes against the

property.

☐☐☐

☐☐☐

SecureView™ Provided - 3 Hasps

SecureView™ Provided - 16, 3” Lag screws – 7/17 Hex Head

Installer supplied – 120 VAC circular saw with a high count blade.

(Carbide recommended.)

Installer supplied – 7/16” or 11 mm nut driver or socket wrench.

Installer supplied – drill bits ¼”, 7/32”, 3/16”

Installer supplied – 3 locks - Puck or Disc locks recommended. *See Below

Page 27: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 26 | P a g e

☐ Screw the hinge to the house. Use the seven (7) remaining lag screws to

anchor the Door System hinge into the structure.

☐ A pilot hole must be drilled for each lag screw. 7/32” for hardwood or 3/16” for

soft wood.

☐ Close the door against the lock hasps. Mark the eyelet locations onto the cover.

☐ Drill a series of 1/4” holes along the eyelet location marks to create a slot to allow theeyelet to pass through the cover.

☐ Peel the film from both sides of the Door System.

☐ Place a Puck lock or Disc lock on each of the three eyelets.

Recommended Lock Styles

Puck Lock Disc Lock

Standard Padlock NOT recommended

Page 28: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 27 | P a g e

Q & A

58. MOST FREQUENTLY ASKED QUESTIONS

☐ Q. Can I order over the phone?

A. You can call your sales representative directly. Not sure who your sales representative is? Call the MFS Supply main phone line (855-727-8439) and ask for SecureView. For specific SecureView questions contact our product specialist at: [email protected]

☐ Q. Why do I have to provide my payment information when I create anaccount?

A. We ask that users provide their payment information at time of account creation so that the purchasing process is quick and easy. NOTE: You may change your billing information at any time.

☐ Q. Does SecureView™ cut the polycarbonate sheets to the size I need?

A. No. Installers must cut the sheets on site to ensure the best possible installation.

☐ Q. How do I determine how much material I need?

A. SecureView™ is available in three (3) sizes and are prices

HARDWARE IS NOT INCLUDED.

For larger installations we encourage you to purchase CUTLIST PLUS software to maximize the output of each sheet. CUTLIST PLUS software can be purchased at:

http://cutlistplus.com/secureviewusa/

☐ Q. How long until my order is ready to be picked up?

A. With a centrally located manufacturing plant in Indiana, andmultiple distribution centers throughout the U.S., once an order isplaced, we strive to fill it as quickly as possible. We suggestcustomers call the pickup location on their paid invoice prior topicking up their products.

Page 29: Vacant Property Boarding · many types of adhesive bonding, welding and mechanical fastening techniques. Since some of these materials can cause environmental stress cracking, please

Rev. 022718 28 | P a g e

☐ Q. Where do I pick up my order?

A. The name, address and phone number of the pickup location youselect will be listed on your order invoice. A list of allSecureView™ distribution locations can be found here:http:// www .securev iewusa.co m/ lo catio ns

☐ Q. What information do I need when picking up my order

A. Your sales rep will provide you with a Purchase Order Number which will act as your Pickup Number.

☐☐ Q. Can my order be delivered?

A. Yes. SecureView™ shipments can be sent to a location of your choice within approximately 100 miles of our distribution centers. If customers cannot have their orders sent directly to their business site we can help make arrangements for products to be delivered at a more convenient location. At no charge we can reroute shipments to be held at a local trucking terminal that can be utilized as a product pick up location. Delivery locations must be able to accommodate an LTL shipment. Customers are responsible for unloading their shipment.

☐ Q. Do I need to be present to accept a delivery?

A. Yes. Delivery personnel are not permitted to leave shipments unattended. Someone must be available to accept and unload shipment.☐ Q. Can my order be returned?

A. In all cases, it is the customer's responsibility to inspect the product prior to accepting pickup at one of our distribution hubs. Accepting material is confirmation that product is not damaged or defective. With this in mind, please understand that we do not accept returned products UNLESS they are damaged in transit or defective, or we accidentally sent the wrong product. If for some reason our products do not meet your expectations, please let us know. We will do our best to ensure that you remain a satisfied customer. Any input on how we can improve our products or customer service to better serve our valued customers is greatly appreciated.

Any additional questions please contact us toll free at 855-727-8439or on the web at www.secureviewusa.com