UvA-DARE is a service provided by the library of the University of Amsterdam (http://dare.uva.nl) UvA-DARE (Digital Academic Repository) Dynamic haemodynamics Cherpanath, T.G.V. Link to publication Citation for published version (APA): Cherpanath, T. G. V. (2016). Dynamic haemodynamics. General rights It is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulations If you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: https://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible. Download date: 13 Jun 2020

Upload: others

Post on 06-Jun-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

UvA-DARE is a service provided by the library of the University of Amsterdam (http://dare.uva.nl)

UvA-DARE (Digital Academic Repository)

Dynamic haemodynamics

Cherpanath, T.G.V.

Link to publication

Citation for published version (APA):Cherpanath, T. G. V. (2016). Dynamic haemodynamics.

General rightsIt is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s),other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons).

Disclaimer/Complaints regulationsIf you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, statingyour reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Askthe Library: https://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam,The Netherlands. You will be contacted as soon as possible.

Download date: 13 Jun 2020

Page 2: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

Chapter 13

Summary and general discussion

Cherpanath TGV

Page 3: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness
Page 4: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

225

SummaryThe focal point of this thesis centres around three main elements of dynamic haemodynamics: fluid responsiveness, ventilator-induced dynamic parameters and ventilator-induced myocardial dysfunc-tion (VIMD). Haemodynamically unstable mechanically ventilated patients are often initially treated with fluid administration. Al-though rapid fluid loading can serve as an important part of the re-suscitation bundle, one must realise that both insufficient as well as overzealous fluid administration increases morbidity and mortality. To make matters worse, a positive response to fluid administration termed fluid responsiveness is hard to predict as it equals a coin flip in critically ill patients. Therefore, a thorough understanding of the underlying physiological principles is of the utmost importance for correct prediction of fluid responsiveness. The remarkable absence of a formal definition of fluid responsiveness further hampered the ultimate goal of patient-tailored volume titration and needed to be resolved. While ventilator-induced dynamic parameters can be helpful in assessing fluid responsiveness when certain require-ments are met, their reliability during changes in arterial compli-ance and positive end-expiratory pressure remained unknown. Moreover, mechanical ventilation by itself might negatively affect myocardial function, fuelling the search for alternative ways to assess fluid responsiveness. Several more recent methods such as passive leg raising and the mini-fluid challenge circumvent the ne-cessity of mechanical ventilation, yet their reliability in predicting fluid responsiveness needed to be established. All these topics on the three elements of dynamic haemodynamics were investigated and described in the following chapters divided in four parts covering physiological principles, experimental studies, clinical studies and future perspectives.

Part I Physiological principlesChapter 2 provides a review of the complex physiology of cardiopul-monary interactions in the critically ill during spontaneous breath-ing and mechanical ventilation. An important difference concerns the intrathoracic pressure, being negative with spontaneous breathing and predominantly positive with mechanical ventilation. The posi-tive intrathoracic pressure reduces right ventricular preload while

Page 5: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

226

the applied positive airway pressure has the potential to increase right ventricular afterload as can be depicted from Figure 2.5. These changes in right ventricular loading conditions serve as the main determinants of the subsequent decrease in cardiac output frequently observed during mechanical ventilation, leading to the believe that effects of mechanical ventilation on left ventricular function are mostly secondary. However, it remains crucial for clinical decision-making to reveal whether the haemodynamic compromise is driven by preload, afterload and/or ventricular dysfunction. Using low tidal volume ventilation may reduce intrathoracic pressures and the need to apply high inspiratory airway pressures potentially ameliorating ventilator-induced haemodynamic compromise, while the effect on myocardial function needs to be further elucidated.

In Chapter 3 we present the potential of fluid responsiveness to en-able tailor-made fluid titration in the treatment of haemodynamically unstable critically ill patients. Although the cornerstone of resuscita-tion is often considered to be fluid administration, assessing one’s volume status can be challenging especially when realising that both too little and too much fluid loading can be deleterious. The relation between the venous return curve and the cardiac function curve, graphically illustrated by Guyton, improves our understanding of the fluid responsiveness concept. It is instrumental to imagine a pa-tient’s position on the combined curve to assess whether an increase in cardiac output is to be expected from fluid loading (Figure  3.3). Furthermore, the curve offers an explanation for the observed su-periority of ventilator-induced dynamic parameters, namely stroke volume variation and pulse pressure variation, in predicting fluid responsiveness compared to static parameters such as central venous pressure (Table 3.1). However, the clinical use of ventilator-induced dynamic parameters are limited by several requirements including controlled mechanical ventilation with tidal volumes > 8 ml/kg as well as a regular heart rhythm. Unsurprisingly, these conditions are seldom encountered on the Intensive Care Unit. Passive leg raising could serve as an attractive alternative to predict fluid responsiveness at the bedside in a broad population of critically ill patients creating a temporary increase in biventricular preload. The subsequent effect on cardiac output is preferably tracked continuously to allow the evalu-

Page 6: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

227

ation of repeated fluid administrations facilitating patient-tailored volume titration.

Part II Experimental studiesChapter 4 describes the relationship between centrally measured stroke volume variation and peripherally derived pulse pressure variation during increased arterial compliance in the setting of normovolaemia and hypovolaemia. To induce a change in arterial compliance, rats were randomised to receive nebulised lipopolysac-charide or saline. To create a hypovolaemic state, a balloon positioned in the inferior vena cava was inflated for a maximum of 30 seconds. Stroke volume was measured directly in the left ventricle using an in-traventricular conductance catheter, while pulse pressure was derived from the carotid artery. Stroke volume variation and pulse pressure variation were calculated over three controlled mechanical ventila-tor cycles. The rats subjected to lipopolysaccharide demonstrated increased arterial compliance calculated by stroke volume divided by pulse pressure. All rats showed increased stroke volume variation and pulse pressure variation upon balloon inflation suggestive of hypovolaemia. Although stroke volume variation and pulse pressure variation were correlated during normovolaemia and hypovolaemia in untreated rats, there were no such correlations during increased arterial compliance. The data from this experimental animal model suggest that pulse pressure variation may not be used as an indicator of stroke volume variation in the setting of a changed arterial tone such as in sepsis.

In Chapter 5 we used a two-hit animal model to investigate if high tidal volume ventilation causes left ventricular dysfunction and whether this is augmented during acute lung injury. Rats were ran-domised to two ventilation strategies: a low tidal volume strategy using a tidal volume size of 6 ml/kg vs. a high tidal volume strategy with tidal volumes of 19 ml/kg. Acute lung injury was created through the administration of intrapulmonary lipopolysaccharide. Left ventricular systolic and diastolic function were assessed by pressure-volume loops obtained within seconds following vena cava occlusion to acquire parameters which are relatively load-independent. Left ventricular function, both systolic as diastolic, decreased during

Page 7: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

228

acute lung injury and high tidal volume ventilation. The combination of high tidal volume ventilation plus lipopolysaccharide aggravated left ventricular dysfunction probably contributing to the death of all rats in this group, while all rats in the other groups survived till the end of the experiment. The data supports the existence of VIMD, in particular in the setting of acute lung injury. Low tidal volume venti-lation has the potential to ameliorate left ventricular dysfunction, yet needs to be confirmed in clinical studies.

Part III Clinical studiesChapter 6 attempts to validate the experimental findings of Chapter 5 in critically ill patients investigating whether low tidal volumes are protective against VIMD compared to high tidal volumes. Since a mechanical ventilator strategy incorporating low tidal volumes is already considered standard care in patients with the acute respira-tory distress syndrome (ARDS), myocardial function was assessed in non-ARDS patients ventilated > 24 hours in the Intensive Care Unit. Left and right systolic and diastolic parameters were measured us-ing transthoracic echocardiography in 42 patients. The myocardial performance index was chosen as primary parameter for myocardial function as it combines systolic and diastolic function. Patients subjected to high tidal volumes averaging 9.5 ml/kg demonstrated decreased left and right myocardial function compared to patients following a low tidal volume strategy with a mean tidal volume size of 6.5 ml/kg. Systolic parameters were higher in the group receiving low tidal volumes, but no difference in diastolic parameters was observed between both groups. This clinical study advocates the use of low tidal volumes to reduce systolic VIMD in patients without ARDS.

In Chapter 7 we examined whether right ventricular stroke volume variation is affected by positive end-expiratory pressure (PEEP) in controlled mechanically ventilated patients. Stroke volume variation was obtained through thermodilution using a pulmonary artery catheter with a rapid-response thermistor during different levels of PEEP. Right ventricular stroke volume variation and the coefficient of variation of all other thermodilution-derived parameters remained unaltered upon PEEP changes. This may be explained by cyclic coun-teracting changes in preload and afterload during the ventilatory cycle

Page 8: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

229

independent of PEEP. The unchanged variation in right ventricular stroke volume implies that the policies regarding the number and timing of pulmonary artery catheter measurements remain unaltered with changing PEEP. This is clinically relevant since thermodilution is still commonly used as the gold standard for cardiac output mea-surements.

Chapter 8 presents a prospective clinical study investigating whether a mini-fluid challenge can be used as a predictor of fluid responsive-ness in postoperative cardiac surgery patients. Since the volume that is minimally required is dependent on the measurement technique of the subsequent change in cardiac output, we compared two different pulse contour analysis methods: the un-calibrated modified Model-flow® and calibrated PulseCO®. Patients received 500 ml of fluids, albeit in 10 consecutive fluid boluses of 50 ml with cardiac output measurements following each bolus. The Modelflow® could correctly predict fluid responsiveness following a mini-fluid challenge of 150 ml, while the PulseCO® required 50 ml more. This data shows that the mini-fluid challenge can reliably predict fluid responsiveness as-sessed by pulse contour analysis, reducing unnecessary fluid loading.

In Chapter 9 we explored whether the ventilator-induced dynamic parameter central venous pressure variation (CVPV) could predict fluid responsiveness in contrast to the static parameter central venous pressure, yet similar to the other ventilator-induced dynamic param-eters stroke volume variation and pulse pressure variation. Therefore, the study was performed in postoperative patients subjected to controlled mechanical ventilation with tidal volumes of 8-10 ml/kg without cardiac arrhythmia to fulfil the requirements for dynamic parameters to predict fluid responsiveness. CVPV was obtained from a central venous catheter calculated as 100 × (CVPmax − CVPmin) / [(CVPmax + CVPmin) / 2]. Stroke volume variation and pulse pressure variation were measured using the modified Modelflow®. Most patients were fluid responders, in whom CVPV decreased upon fluid loading in contrast to non-responders. CVPV was correlated with the change in cardiac output in contrast to central venous pressure. Moreover, CVPV could identify all fluid responders and non-responders correctly at a cut-off value of 12% with no difference in the area under the receiver

Page 9: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

230

operating characteristic curve (AUROC) compared to stroke volume variation and pulse pressure variation. So despite the fact that central venous pressure is generally useless to determine fluid responsive-ness, detailed analysis of the variation in central venous pressure induced by mechanical ventilation can be useful serving this purpose.

Part IV Future perspectivesChapter 10 focused on a novel definition of fluid responsiveness as a generally excepted definition was still lacking. Through a compre-hensive literature search the different amounts, timing and type of fluids were reviewed as well as the best physiological parameter and measurement technique. This resulted in the following definition of fluid responsiveness: “an improvement in a physiological parameter preferably cardiac output within 15 minutes superseding twice the er-ror of the measuring technique following a 15-minute administration of 6 ml/kg crystalloids”.

In Chapter 11 we performed a meta-analysis to ascertain whether passive leg raising can be used in future clinical protocols to reliably assess fluid responsiveness in different clinical settings and patient groups. Although passive leg raising creates an increase in venous return, the amount of recruited volume may vary in various clini-cal settings. Moreover, the preferred measurement techniques and outcome parameters upon passive leg raising were systematically reviewed. Twenty-three clinical trials were analysed combining 1013 patients resulting in a pooled sensitivity of 86%, specificity of 92%, and summary AUROC of 0.95. Different modes of ventilation, type of fluids, or measurement techniques did not affect the diagnostic performance of passive leg raising. A passive leg raising-induced change in pulse pressure as outcome parameter demonstrated a lower diagnostic performance compared to a change in a flow parameter such as cardiac output. This meta-analysis provides proof that passive leg raising can be used as a substitute of the classic fluid challenge to predict fluid responsiveness in various clinical settings. Nonetheless, the effect of passive leg raising needs to be determined by a rapid and direct assessment of cardiac output or its derivative.

Page 10: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

231

Finally, in Chapter 12 we extend our research on VIMD to a patient with severe ARDS in whom low tidal volume ventilation was not achievable due to respiratory acidosis. Additionally, marked right ventricular dysfunction and haemodynamic instability was present. An extracorporeal lung assist device primarily eliminating carbon dioxide was initiated enabling a reduction in applied tidal volume. A marked improvement of right ventricular function with restoration of haemodynamic stability was noted during simultaneous improve-ment in oxygenation, decarboxylation and acidosis. This case report shows that the recent emergence of extracorporeal lung assist devices in the Intensive Care Unit may facilitate a low tidal volume strategy potentially protecting against the development and/or progression of VIMD.

General discussionThe results of the studies presented in this thesis demonstrate the clinical importance of dynamic haemodynamics. However, it is imperative to have a thorough understanding of the underlying physiological principles (Chapter 2 and 3). One famous example of misinterpretation of dynamic haemodynamics is embedded in the term pulsus paradoxus. Normal inhalation can account for a decrease up to 10 mmHg in systolic blood pressure, so the inspiratory decline in systolic blood pressure of more than 10 mmHg observed in pulsus paradoxus is hardly ‘paradox’ and can better be described as an exag-geration of ordinary cardiopulmonary interaction.1 Kussmaul should not be faulted for this rather innocent erroneous terminology as he described this phenomenon almost 150 years ago.2 On the other hand, the unwarranted and potentially deleterious use of central venous pressure to guide fluid titration has persisted over the last 50 years,3,4 retaining recommendation in current international guidelines.5 From the combined venous return curve / cardiac function curve shown in Figure 3.3, it can easily be depicted that a given central venous pres-sure cannot predict fluid responsiveness. Furthermore, the figure explains that unwarranted fluid loading not only fails to generate a significant increase in cardiac output, but may cause a sharp increase in cardiac filling pressures instead. It is therefore of no surprise that both insufficient as overzealous fluid loading has the propensity to

Page 11: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

232

increase morbidity and mortality (Figure 13.1).6–9 In two recent meta-analyses, Marik et al. has convincingly demonstrated that central venous pressure barely beats a coin flip in various clinical settings (Table 10.1).10,11 Interestingly, the one study describing the usefulness of central venous pressure to predict the volume status was performed in a haemorrhagic model of standing horses.12 Left ventricular end-diastolic area has been viewed as a superior marker of left ventricular preload compared to central venous pressure and its assessment using echocardiography is increasingly employed in the peri-operative setting.13-16 Nev-ertheless, left ventricular end-diastolic area does not establish a patient’s position on the combined venous return / cardiac function curve either and is therefore not able to reliably pre-dict fluid responsiveness (Table  3.1),17 rather similar to the global end-diastolic volume index obtained by transpulmonary thermodilution.18,19 Even baseline cardiac output, generally re-garded as the ultimate physiological parameter, demonstrates

only a moderate diagnostic performance to predict fluid responsive-ness.20-22 We must conclude that static haemodynamic parameters cannot lead to a proper prediction since a single value simply does not discriminate a patient’s position on the curve. Ideally, multiple cardiac output measurements are obtained during changes in preload for this purpose.Mechanical ventilation can cause cyclic impediment of biventricular preload and can thus serve as a vehicle to predict fluid responsiveness. Indeed, ventilator-induced changes in stroke volume and pulse pres-sure have shown the capability to predict fluid responsiveness, con-firmed by another meta-analysis of Marik et al.23 The predictive value of these ventilator-induced dynamic parameters largely depend on a predictable and sufficient change in preload to assess the patient’s location on the curve. This explains the numerous requirements such as a regular heart rhythm and controlled mechanical ventilation with tidal volumes > 8 ml/kg severely limiting the use of ventilator-induced dynamic parameters in the Intensive Care Unit.24-27 Nevertheless, these conditions are more often present in the operating room enabling the clinical applicability of ventilator-induced central venous pressure variation to predict fluid responsiveness described in Chapter 9. This is even more relevant, since pulse pressure variation might not reflect

Mor

talit

y

Underresuscitation Overresuscitation

Figure 13.1 Fluid administration is commonly used as initial resuscitation step. However, both under- and overresuscitation can increase mortality. This empha-sises the importance of correct fluid responsiveness prediction to navigate between the proverbial Scylla and Charybdis. It is imperative to first establish whether hypoperfusion is present before attempting to augment cardiac output through fluid administration.

Page 12: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

233

stroke volume variation in the setting of changing arterial compli-ance (Chapter 4) frequently encountered in the operating room, for example upon the use of anaesthetics. This observation further emphasised the need for a more clear statement on the preferred outcome parameter (Chapter 10).Although our proposed gold standard for fluid responsiveness con-sists of the administration of fluids, a random fluid challenge has generally a 50/50 chance to unveil a fluid responder.17,23 This generates a paradox, in which half of patients will receive potentially deleterious fluid loading to determine their fluid responsiveness. The mini-fluid challenge can serve as an alternative method minimising the amount of fluid necessary to predict fluid responsiveness (Chapter 8). A reversible fluid challenge would be ideal, which can be accomplished at the bedside through passive leg raising. Our meta-analysis shows that passive leg raising retains a high diagnostic performance in vari-ous patient groups (Chapter 11). This holds true for certain clinical settings in which patients breath spontaneously, where ventilator-induced dynamic parameters cannot be used. Moreover, even in the setting of controlled mechanical ventilation with tidal volumes > 8 ml/kg enabling the use of ventilator-induced dynamic parameters, one should realise that high tidal volume ventilation carries the risk of in-ducing VIMD (Chapter 5, 6 and 12). Mechanical ventilation with high tidal volumes had already demonstrated the potential to contribute to lung injury,28,29 previously regarded as the primary explanation for the observed increased morbidity and mortality in ARDS patients.30 Recent experimental studies have shown the release of inflamma-tory mediators upon high tidal volume ventilation resulting in extra-pulmonary injury as well,31,32 probably contributing to the aforemen-tioned decline in survival. We observed that the development of VIMD correlates with tidal volume size, while the effect is magnified in the setting of acute lung injury. This may explain the absence of diastolic VIMD in the non-ARDS patients ventilated with a high tidal volume strategy of 9.5 ml/kg in Chapter 6, in contrast to the acute lung injury model with tidal volumes of 19 ml/kg in Chapter 5. Low tidal volume ventilation is thus an important component of a lung protective strat-egy, with growing evidence for a proverbial “the lower, the better” approach,33,34 potentially further mitigating VIMD as well. Although a lung protective ventilation strategy is now considered standard care

Page 13: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

234

in ARDS patients,35 as it has confirmed to improve survival,36,37 this is not always attained in the real world.33,38 Novel technologies such as extracorporeal lung assist devices may help to achieve ‘supra-low’ tidal volume ventilation in this patient group to reduce additional lung injury.39,40 We demonstrate that an extracorporeal lung assist device enabling the application of these very low volumes has the potential to decrease VIMD as well (Chapter 12).

Future researchThe research performed in this thesis demonstrates the relative merits of dynamic haemodynamics to assist clinicians caring for critically ill patients in their decision whether or not to administer fluids. Howev-er, robust randomised controlled trials using a valid fluid responsive-ness protocol in the Intensive Care Unit are regrettably still lacking. Furthermore, no studies have been done to investigate whether fluid responsiveness can aid in ‘deresuscitation’: accomplishing a negative fluid balance while preserving adequate perfusion. These strategies need to be tested in sufficiently powered trials to investigate their impact on hard clinical endpoints.

Conclusion“To fill or not to fill”, that is the question this thesis has primarily aimed to answer. Although ventilator-induced dynamic parameters may be helpful in this assessment, the required high tidal volumes carry the risk of inducing myocardial dysfunction. Several alternative methods to assess fluid responsiveness are available to accomplish the ultimate goal of tailor-made fluid titration in critically ill patients.

Page 14: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

235

References1. Abu-Hilal MA, Mookadam F. Pulsus paradoxus; His-

torical and clinical perspectives. Int J Cardiol 2010; 138: 229–232.

2. Kussmaul A. Über schwielige mediastino-pericarditis und den paradoxen puls. Berliner Klinische Wochen-schrift 1878; 10: 461.

3. Hughes RE, Magovern GJ. The relationship between right atrial pressure and blood volume. AMA Arch Surg 1959; 79: 238–243.

4. Wilson JN, Grow JB. Central venous pressure in optimal blood volume maintenance. Arch Surg 1962; 85: 55.

5. Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, Sevransky JE, Sprung CL, Douglas IS, Jaeschke R, Osborn TM, Nunnally ME, Townsend SR, Reinhart K, Kleinpell RM, Angus DC, Deutschman CS, Machado FR, Rubenfield GD, Webb S, Beale RJ, Vincent JL, Moreno R. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock. Intensive Care Med 2013; 39: 165–228.

6. Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M; Early Goal-Directed Therapy Collaborative Group. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345: 1368–1377.

7. Holte K, Kehlet H. Fluid therapy and surgical outcomes in elective surgery: a need for reassessment in fast-track surgery. J Am Coll Surg 2006; 202: 971–989.

8. Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL; National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med 2006; 354: 2564–2575.

9. Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid

balance and elevated central venous pressure are as-sociated with increased mortality. Crit Care Med 2011; 39: 259–265.

10. Marik PE, Baram M, Vahid B. Does central venous pres-sure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134: 172–178.

11. Marik PE, Cavallazzi R. Does the central venous pres-sure predict fluid responsiveness? An updated meta-analysis and a plea for some common sense. Crit Care Med 2013; 41: 1774–1781.

12. Magdesian KG, Fielding CL, Rhodes DM, Ruby RE. Changes in central venous pressure and blood lactate concentration in response to acute blood loss in horses. J Am Vet Med Assoc 2006; 229: 1458-1462.

13. Price S, Nicol E, Gibson DG, Evans TW. Echocardiog-raphy in the critically ill: current and potential roles. Intensive Care Med 2006; 32: 48–59.

14. Guarracino F, Baldassarri R. Transesophageal echocar-diography in the OR and ICU. Minerva Anestesiol 2009; 75: 518–529.

15. American Society of Anesthesiologists and the Society of Cardiovascular Anesthesiologists Task Force on Transesophageal Echocardiography: Practice guide-lines for perioperative transesophageal echocardiog-raphy. An updated report. Anesthesiology 2010; 112: 1084–1096.

16. Cholley BP, Vieillard-Baron A, Mebazaa A. Echo-cardiography in the ICU: time for widespread use! Intensive Care Med 2006; 32: 9–10.

17. Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest 2002; 121: 2000–2008.

18. Huang CC, Fu JY, Hu HC, Kao KC, Chen NH, Hsieh MJ, Tsai YH. Prediction of fluid responsiveness in acute

Page 15: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Epilogue

236

respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pres-sure. Crit Care Med 2008; 36: 2810–2816.

19. De Waal EE, Rex S, Kruitwagen CL, Kalkman CJ, Buhre WF. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. Crit Care Med 2009; 37: 510–515.

20. Auler JO Jr, Galas F, Hajjar L, Santos L, Carvalho T, Michard F. Online monitoring of pulse pressure varia-tion to guide fluid therapy after cardiac surgery. Anesth Analg 2008; 106: 1201–1206.

21. Perner A, Faber T. Stroke volume variation does not predict fluid responsiveness in patients with septic shock on pressure support ventilation. Acta Anaesthe-siol Scand 2006; 50: 1068–1073.

22. Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ. Respiratory variations in pulse oximetry plethysmographic waveform ampli-tude to predict fluid responsiveness in the operating room. Anesthesiology 2007; 106: 1105–1011.

23. Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated pa-tients: a systematic review of the literature. Crit Care Med 2009; 37: 2642–2647.

24. Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure varia-tion for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest 2005; 128: 848–854.

25. De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsive-ness: influence of tidal volume. Intensive Care Med 2005; 31: 517–523.

26. Reuter DA, Bayerlein J, Goepfert MS, Weis FC, Kilger E, Lamm P, Goetz AE. Influence of tidal volume on left

ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 2003; 29: 476–480.

27. Sondergaard S. Pavane for a pulse pressure variation defunct. Crit Care 2013; 17: 327.

28. Pinhu L, Whitehead T, Evans T, Griffiths M. Ventilator-associated lung injury. Lancet 2003; 361: 332–340.

29. Slutsky AS, Ranieri VM. Ventilator-induced lung injury. N Engl J Med 2013; 369: 2126–2136.

30. The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342: 1301–1308.

31. Nin N, Penuelas O, de Paula M, Lorente JA, Fernández-Segoviano P, Esteban A. Ventilation-induced lung in-jury in rats is associated with organ injury and systemic inflammation that is attenuated by dexamethasone. Crit Care Med 2006; 34: 1093–1098.

32. Brander L, Sinderby C, Lecomte F, Leong-Poi H, Bell D, Beck J, Tsoporis JN, Vaschetto R, Schultz MJ, Parker TG, Villar J, Zhang H, Slutsky AS. Neurally adjusted ventilatory assist decreases ventilator-induced lung injury and non-pulmonary organ dysfunction in rabbits with acute lung injury. Intensive Care Med 2009; 35: 1979–89.

33. Needham DM, Colantuoni E, Mendez-Tellez PA, Dinglas VD, Sevransky JE, Dennison Himmelfarb CR, Desai SV, Shanholtz C, Brower RG, Pronovost PJ. Lung protective mechanical ventilation and two year survival in patients with acute lung injury: prospective cohort study. BMJ 2012; 344: 2124.

34. Hager DN, Krishnan JA, Hayden DL, Brower RG. Tidal volume reduction in patients with acute lung injury when plateau pressures are not high. Am J Respir Crit Care Med 2005; 172: 1241–1245.

Page 16: UvA-DARE (Digital Academic Repository) Dynamic ... › ws › files › 2789956 › 172428_13.pdfPassive leg raising could serve as an attractive alternative to predict fluid responsiveness

13

Summary and general discussion

237

35. Esteban A, Ferguson ND, Meade MO, Frutos-Vivar F, Apezteguia C, Brochard L, Raymondos K, Nin N, Hurtado J, Tomicic V, González M, Elizalde J, Night-ingale P, Abroug F, Pelosi P, Arabi Y, Moreno R, Jibala M, D’Empaire G, Sandi F, Matamis D, Montañez AM, Anzueto A. Evolution of mechanical ventilation in response to clinical research. Am J Respir Crit Care Med 2008; 177: 170–177.

36. Villar J, Kacmarek RM, Pérez-Méndez L, Aquirre-Jaime A. A high positive end-expiratory pressure, low tidal volume ventilatory strategy improves outcome in persistent acute respiratory distress syndrome: a randomized, controlled trial. Crit Care Med 2006; 34: 1311–1318.

37. Amato MB, Meade MO, Slutsky AS, Brochard L, Costa EL, Schoenfeld DA, Stewart TE, Briel M, Talmor D, Mercat A, Richard JC, Carvalho CR, Brower RG. Driving pressure and survival in the acute respiratory distress syndrome. N Engl J Med 2015; 372: 747–755.

38. Oh DK, Lee MG, Choi EY, Lim J, Lee HK, Kim SC, Lim CM, Koh Y, Hong SB. Low-tidal volume mechanical ventilation in patients with acute respiratory distress syndrome caused by pandemic influenza A/H1N1 infection. J Crit Care 2013; 28: 358–364.

39. Bein T. Weber-Carstens S, Goldmann A, Müller T, Staudinger T, Brederlau J, Muellenbach R, Dembinski R, Graf BM, Wewalka M, Philipp A, Wernecke KD, Lub-now M, Slutsky AS. Lower tidal volume strategy (≈3 ml/kg) combined with extracorporeal CO

2 removal versus ‘conventional’ protective ventilation (6 ml/kg) in severe ARDS: the prospective randomized Xtravent-study. Intensive Care Med 2013; 39: 847–856.

40. Marhong JD, Munshi L, Detsky M, Telesnicki T, Fan E. Mechanical ventilation during extracorporeal life sup-port (ECLS): a systematic review. Intensive Care Med 2015; 41: 994–1003.