Page 1: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100 00000/UNIBuyLine 0000

selectorconstruction

Page 2: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

IntroductionUSG Corporation companies offer a wide range of quality products andperformance-engineered systems to meet specialized requirements formodern building design. The manufacture of these products to carefullycontrolled standards ensures uniform quality. This Construction Selectorcovers products and systems from two USG Corporation companies:

United States Gypsum Company manufactures gypsum products,cement board panels, and related components for high-performancesystems. The Company has been a leader in the building industry since itsfounding in 1902.

USG Interiors, Inc., manufactures commercial ceiling products,relocatable partitions, and mineral fiber insulation for building construction.The Company offers the widest product range in the industry and has theunique capability to market integrated interior systems.

The USG Research and Technology Center, largest and most advancedin the industry, continually develops new products and high-performancesystems which are designed to provide improved function and utility whilereducing construction time and cost. Products and systems are marketedonly after thorough testing and field trial.

USG Corporation employs technical service and sales representatives tohelp design professionals gain maximum performance from materials andsystems by advising on selection, proper detailing, and specifications. Seethe back cover for contact information.

ContentsThe USG Architectural Reference Library has one binder devoted to U.S.Gypsum Company products and systems, and separate literature dedicatedto USG Interiors, Inc. Because of the different criteria used for selection fromthese two volumes, the USG Interiors binder uses a different format, whilethe U.S. Gypsum Company binder contains the same folders familiar fromprevious editions, numbered and organized according to CSI divisions.

This Construction Selector is the key reference index to the USGArchitectural Reference Library. It summarizes fire-rated construction andacoustical performance data for various systems to permit quick comparisonand selection. Cross-references are provided to the System Folders thatcontain complete descriptions, installation details and specifications.Product Folders provide technical data on components used in constructionsystems.

The table below gives the sequence of folders comprising the USGArchitectural Reference Library. The numeral before each division titleindicates the CSI MASTERFORMAT Division classification. Copies of all folderslisted are available through Company sales offices.

The System Folders and Product Folders are arranged in numericalsequence. The first numeral in the title number is the appropriate divisionnumber (two digits for two-digit division numbers) so that folders can easilybe filed.

Folder No. & Title Section No.

Div. 7/Thermal & Moisture ProtectionSA700 Exterior Substrate Systems 07240SA727 USG™ Fire Stop Systems 07840

Div. 9/FinishesSA920 Plaster Systems 09210SA923 Drywall/Steel Framed Systems 09250SA924 Drywall/Wood Framed Systems 09250SA925 USG Area Separation Fire Wall/Party Wall Systems 09250SA926 USG Cavity Shaft Wall Systems 09250SA927 Gypsum Panels & Accessories 09250SA928 SHEETROCK® Brand Vinyl-Faced Gypsum Panels 09720SA929 Abuse-Resistant Systems 09250SA932 DUROCK® Brand Cement Board Systems 09305SA933 SHEETROCK® Brand Textures and Finish Products 09940

Div.11/EquipmentSA1119 STRUCTOCORE™ Security Wall Systems 11190

2

Page 3: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

How to Use This SelectorThis folder is divided into nine sections—A to I—covering the categoriesindicated below. Within the first six sections are listed brief analyses asdocumented by fire or sound tests, federal specifications, ASTMdesignations, or other pertinent criteria. They usually are arrangedsequentially according to fire ratings—the criterion that most often governsselection.

The analysis applicable to each system, as listed in the sections Athrough F, are repeated in the individual folder covering that system,indicated by number in the “Folder Reference” column.A Partitions—pages 6 to 16—include mechanically fastened and

laminated assemblies, demountable, steel- and wood-framed, load-bearing and non-load-bearing—in gypsum base and veneer finishes,gypsum drywall, cement board and conventional lath and plaster.

B Ceilings—pages 17 to 31—include suspended, furred, and direct-attachment types, employing drywall, veneer finishes, conventionalplaster, and mineral fiber tile or panel surfaces with companion floor orroof construction.

C Structural fireproofing—pages 32 to 34—shows basic methods ofprotecting columns and beams with gypsum base and veneer finishes,mineral fireproofing, and gypsum drywall.

D Exterior walls—pages 35 to 36—includes load-bearing wood andsteel stud systems and exterior curtain wall assemblies.

E Exterior wall furring—page 37—compares methods of furringexterior walls, including veneer and conventional plaster and drywallfurring systems.

F Through-penetration and head-of-wall firestop systems—pages38 to 40—provides firestop systems to block smoke and flames frompassing through floor and wall penetrations and the intersection of firerated walls and the floor or roof above.

G Metric Conversions—page 41—includes information on metric-sizedproducts.

H Product and system catalogs—page 42—provides a briefdescription of each catalog in the Architectural Reference Library.

I Products/specification standards—pages 42-43—Federalspecification and ASTM designation qualifications of USG Corporationproducts; UL designations; code research reports; and NER listings.

Test Conditions and CertificationFire and sound tested assemblies listed in this Selector are based oncharacteristics, properties and performance of materials and systemsobtained under controlled test conditions as set forth in the appropriateASTM Standard in effect at the time of test. These listings are shortsummaries to serve as a compilation and guide of construction assembliesavailable in the selection process. For complete information on constructiondetails and components used in these systems, refer to the individual Folderreference.

USG Corporation will provide certification for published fire, sound andstructural data covering systems designed and constructed according to itspublished specifications. Tests are conducted on Company productsassembled to meet performance requirements of established testprocedures specified by various agencies. System performance followingany substitution of materials or compromise in assembly design cannot becertified and may result in failure under critical conditions.

Sound tests are conducted under controlled laboratory conditionsaccording to ASTM procedures. Comparable field performance depends onbuilding design and careful attention to detailing and workmanship.

Certain sound tests, conducted in accordance with ASTM methods,measured sound transmission of 11 frequencies. These data have beenretained in this selector to serve as a guide to the designer. Based onexperience, the STC values are very close to those obtained for theassembly under current methods at 16 frequencies.

Sound ratings shown for steel-framed partitions apply to systemsconstructed with 25 ga. steel studs, unless otherwise noted. Heavier gaugestuds are more rigid and may not provide the same sound ratings.

AbbreviationsIn the test analysis following, abbreviation of “est” indicates estimated;abbreviation N/A indicates not applicable or not available. Estimated fireratings are based on an engineering evaluation by qualified professionals.Other abbreviations are shown below.

acoust acoustical ht heightalt alternate insul insulating or insulationalum aluminum int interiorappl applied lamin laminatedASTM Amer. Soc. for Testing and Materials lbr lumberatt attached lightwt lightweightatten attenuation lim limitingbetw between max maximumbd board met metalblkts blankets min mineral or minimumcem cement nom nominalchan channel noncomb noncombustibleclg ceiling o.c. on centercol column opp oppositecom common oz ounceconc concrete partn partitioncontin continuous perim perimeterconv conventional plywd plywoodcorrug corrugated prot protected or protection cr cold rolled qtr quarterctd coated recom recommendeddbl double reg regularDes Design rel relocatableea each resil resilientexp exposed run runner(s)extendg extending SAFB sound attenuation fire blanketsfin finish or finished sep separatefireprfg fireproofing separ separatedfixt fixture stag staggeredflr floor stl steelfreq frequency subflr subfloorft foot or feet susp suspended or suspensionfur furring syst systemga gauge thickn thicknessGA Gypsum Association unfin unfinishedgalv galvanized USG USG Corporationhex hexagonal vert verticallyhoriz horizontally wd woodhr hour wt weight (lb./sq. ft.)

DetailsIn details, shaded backgrounds designate materials indicated below:

AgenciesFire SoundUL—Underwriters Laboratories Inc. RAL—Riverbank Acoustical LaboratoriesOSU—Ohio State University G & H—Geiger & HammeU of C—University of California CK—Cedar Knolls Acoust. LaboratoriesWHI—Warnock Hersey International BBN—Bolt, Beranek and NewmanCEG—Consulting Engineers Group KAL—Kodaras Acoustical LaboratoriesGA—Gypsum Assoc. (Fire Resistance SA—Shiner & Assoc.

Design Manual GA-600)

Sound ratingSTC sound transmission class per IIC impact insulation class per

ASTM test procedures ASTM test procedures

CAC ceiling attenuation class— MTC music/machineryper ASTM procedures transmission class

SA100/USG Corporation 3

Furring channels.RC-1™ Resilient Channels or equivalent.

Sound-deadening material; column or beam fireproofing.

Page 4: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

4

Product or System Folder Reference

AAccessories, structural & trim...........................SA920, SA927Acoustical ceiling finish, spray ......................................SA933Acoustical ceilings .....................................................SC2000Acoustical sealant........................................................SA927Adhesives, ceramic tile ................................................SA932Adhesives, drywall .......................................................SA927Aluminum foil-backed panel .............................SA920, SA927Area separation walls...................................................SA925ASTM Specs ..........................................pages 42-43, SA100

BBack-blocking system..................................................SA924Basecoat plaster..........................................................SA920Brick veneer curtain walls ................................SA700, SA923

CCaged beam construction ................................SA920, SA923Cavity shaft walls........................................................SA926Ceiling heat components ..............................................SA920Ceiling texture finishes .................................................SA933Cement board, exterior.................................................SA700Cement board, interior .................................................SA932Ceramic tile base.................................SA700, SA927, SA932Channels, furring & lathing...............................SA920, SA927Chase walls ............................SA920, SA923, SA924, SA926Column fireproofing .........................................SA920, SA923Concrete fasteners.......................................................SA927Concrete finishing compound ...........................SA920, SA927Construction joints .......................................................SA727Control joints ...................................................SA920, SA927Corner, casing beads.......................................SA920, SA927Curtain walls ...................................................SA700, SA923Curved walls................................................................SA923

DDry-set mortar.............................................................SA932Drywall ceilings ...............................................SA923, SA924Drywall fireproofing......................................................SA923Drywall furring systems................................................SA923Drywall partitions, laminated ...............SA923, SA924, SA926Drywall partitions, steel framed....................................SA923,

SA925, SA926Drywall partitions, wood-framed .......................SA924, SA925

EEIFS............................................................................SA700Exterior curtain walls........................................SA700, SA923Exterior insulation & finish system.................................SA700Exterior walls and ceilings ....................SA700, SA923, SA924

Product or System Folder Reference

FFederal Specs ...............................................page 38, SA100Finishing lime ..............................................................SA920Firestop system, walls & floors .....................................SA727Fire-wall systems.........................................................SA925Floating angle construction...............................SA920, SA924Floor protector, cement board ......................................SA932Foil-back Gypsum Panels, lath..........................SA920, SA927

GGauging plasters..........................................................SA920Grout, ceramic tile ...........................................SA700, SA932Gypsum ceiling board ..................................................SA927Gypsum lath ceilings....................................................SA920Gypsum lath partitions .....................................SA920, SA926Gypsum liner panels ....................................................SA927Gypsum Panels ...............................................SA927, SA928Gypsum plaster bases..................................................SA920

HHead-of-wall construction joints....................................SA727Hearth extension, cement board ...................................SA932

IInsulating furring .............................................SA920, SA923Insulating Gypsum Panels, lath .........................SA920, SA927

JJoint treatment ............................................................SA927

LLathing accessories, clips ............................................SA920Lime, hydrated ............................................................SA920

MMetal lath & accessories ..............................................SA920Metal stud partitions ...........................SA920, SA923, SA925,

SA926Metal trim .......................................................SA920, SA927Mini-brick exterior finish...............................................SA700Mouldings, drywall...........................................SA927, SA928MTC sound rating ........................................................SA923

Product or System Folder Reference

PParty walls .....................................................SA920, SA923,

SA924, SA925Plaster bases...............................................................SA920Plaster ceilings ............................................................SA920Plaster furring systems.................................................SA920Plaster partitions, steel-framed.....................................SA920Plaster partitions, wood-framed ....................................SA920Plastering lime.............................................................SA920Plasters—basecoat, finish ...........................................SA920Plastic trim..........................................SA920, SA927, SA928Poke-thru insulation.....................................................SA727Prefinished gypsum panels...........................................SA928Primer ............................................................SA927, SA933

RRadiant heat ceiling components ..................................SA920Resilient ceilings..............................................SA920, SA924Resilient partitions ...............................SA920, SA924, SA925

SScrews ...........................................................SA920, SA927Security walls ................................................SA920, SA1119Shaft wall partitions .....................................................SA926Sheathing, gypsum......................................................SA927Soffits, drywall.............................................................SA923Sound control partitions ...............................................SA923Sound control floor/ceilings ..........................................SA924Stucco ................................................SA700, SA920, SA923

TTape, reinforcing .............................................SA920, SA927Texture finishes ...........................................................SA933Textured ceilings .........................................................SA933Thin-brick exterior finish...............................................SA700Through-penetrations...................................................SA727Tile accessories...........................................................SA932Tile backer board.........................................................SA932Trim accessories .............................................SA920, SA927

UUnderlayment, floor & counter top.................................SA932

VVeneer finishes............................................................SA920Veneer plaster systems ................................................SA920Vent shaft construction ................................................SA926Vinyl-faced Gypsum Panels ..........................................SA928Vinyl trim ............................................SA920, SA927, SA928

WWallboard & accessories ..............................................SA927Wallcovering, vinyl .......................................................SA928Wall furring systems ............................SA920, SA922, SA923Wall panels, prefinished ...............................................SA928Wall shield, cement board ............................................SA932Wood-frame partitions, ceilings .......................SA920, SA924,

SA925

References listed are principal source ofinformation in this Architectural TechnicalLiterature series. Repetition or additional datamay occur in other folders.Index to Products and Systems

Page 5: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

UL Des. No. Ref.

A A003.............................UL DirA202.............................UL DirA210.............................UL DirA211.............................UL Dir

C-AJC-AJ-0032 .....................F-99 C-AJ-1020 ...............F-1, F-2,

F-29, F-30C-AJ-1081 ...............F-3, F-4,

F-31, F-45, F-46C-AJ-1347 ...............F-5, F-6,

F-32, F-47C-AJ-1348 ....F-7, F-33, F-48C-AJ-2295 .....................F-79 C-AJ-2296 .....................F-80C-AJ-2301......................F-81C-AJ-2304 .....................F-82C-AJ-3045 .....................F-65C-AJ-3174 .....................F-66 C-AJ-3175 .....................F-67C-AJ-5146 ..............F-8, F-49C-AJ-5147 ..............F-9, F-50C-AJ-5148 .....................F-10C-AJ-5149 ..F-11, F-34, F-51C-AJ-7062 .....................F-73C-AJ-7063......................F-74

DD010 ...........................UL DirD205 ...........................UL Dir D209 .............................B-88 D215 .............................B-66 D216 ...........................UL Dir D218 .............................B-61D219 .............................B-62D302 ...........................UL Dir D403 .............................C-20 D501 ...........................UL Dir D502 ...........................UL Dir

F-A F-A-1020 .....F-12, F-35, F-52 F-A-2062 .......................F-83 F-A-2063 .......................F-84 F-A-2064 .......................F-85F-A-5014 ..............F-13, F-53

F-C F-C-1069 ....F-14, F-36, F-54 F-C-1070 .......................F-37 F-C-2179 .......................F-86 F-C-2180 .......................F-87 F-C-2181 .......................F-88F-C-2182 .......................F-89 F-C-2183 .......................F-90F-C-3054 .......................F-68F-C-5042 ..............F-15, F-55

F-F-S F-F-S-0028 ..................F-100

G G002 .............................B-67 G007 .............................B-68 G008 .............................B-69 G011 ...........................UL Dir G017 ...........................UL Dir G018 ...........................UL Dir G020 ...........................UL Dir G022 ...........................UL Dir G036 ...........................UL Dir G037 ...........................UL Dir G040 .............................B-70G201 ...........................B-101 G202 ............................B-71 G203 .............................B-72 G204 ............................B-73 G205 .............................B-63 G208 ...........................UL Dir G209 ...........................UL Dir G210 ............................UL Dir G211 .............................B-64 G213 .............................B-65G214 ...........................UL Dir G215 .............................B-74G217 ...........................UL Dir G218 ...........................UL Dir G222 .............................B-10 G227 .............................B-75 G228 .............................B-76 G229 ...........................UL Dir

UL Des. No. Ref.

G230 .............................B-77 G231 .............................B-78 G234 .............................B-79 G236 ...........................UL Dir G241 ...........................UL Dir G243 ...........................UL Dir G244 ...........................UL Dir G248 ...........................UL Dir G249 ...........................UL Dir G250 ...........................UL Dir G252 .............................B-80 G256 ...........................UL Dir G258 ...........................UL Dir G259 .....................B-3, B-10 G260 ...........................UL Dir G262 .............................B-89G264 .............................B-90 G265 .............................B-81G267 .............................B-91G501 ...........................UL Dir G502 ...............................B-5 G503 ...............................B-7 G512 .............................B-12 G515 ...............................B-6 G520 ...........................UL Dir G521 ...........................UL Dir G523 ...............................B-9 G525 ...........................UL Dir G526 .............................B-10 G527 ...........................UL Dir G528 ...............................B-3 G529 .............................B-13 G530 ...........................UL Dir G531 ...........................UL Dir G533 ...........................UL Dir G534 ...........................UL Dir G540 .............................B-17G541 ............................UL DirG542 ..............................B-17G543..............................B-17G544..............................B-17

HW-D HW-D-0001 .................F-101HW-D-0002 .................F-102 HW-D-0009 .................F-103 HW-D-0158 .................F-104 HW-D-0159 .................F-105 HW-D-0160 .................F-106 HW-D-0161 .................F-107

HW-S HW-S-0001 ......F-108, F-109 HW-S-0032 ......F-110, F-111 HW-S-0035 ......F-112, F-113 HW-S-0036 ..................F-114

JJ201 ..............................B-82J202 ..............................B-83J501.............................UL DirJ502 .....................B-25, B-27J503 ..............................B-25J504 ..............................B-27J917.............................UL DirJ919 .............................UL DirJ920 .............................UL DirJ924 .............................UL DirJ927 .............................UL DirJ931 .............................UL DirJ957 .............................UL DirJ966 .............................UL DirJ991 .............................UL DirJ994 .............................UL Dir

KK906.............................UL Dir

LL003.............................UL DirL006 ..............................B-98L202 ..............................B-99L206 ............................B-100L208.............................UL DirL209.............................UL DirL210.............................UL DirL211 ..............................B-84L212 ............................B-102L501 ..............................B-37L502.............................UL DirL504.............................UL DirL505.............................UL DirL506.............................UL Dir

UL Des. No. Ref.

L508.............................UL DirL510 .....................B-51, B-52L511 ..............................B-53L512 ..............................B-38L513.............................UL DirL514 ..............................B-39L515.............................UL DirL516 ..............................B-43L518.............................UL DirL520.............................UL DirL521 ..............................B-44L523.............................UL DirL524 ..............................B-14L525 ..............................B-49L526.............................UL DirL527 ..............................B-23L528 ..............................B-47L529 ..............................B-48L530 ..............................B-50L531 ..............................B-50L532.............................UL DirL534.............................UL DirL535.............................UL DirL536.............................UL DirL537.............................UL DirL538 ..............................B-56L539.............................UL DirL541 .....................B-54, B-55L542 ..............................B-46L543.............................UL DirL544.............................UL DirL545.............................UL DirL546 ..............................B-44L548.............................UL DirL549 ..............................B-18L550 ..............................B-44L551 ..............................B-18L552 ..............................B-18L553 ..............................B-18

NN501 ....................C-23, C-24N502 ....................C-23, C-24N505 ....................C-21, C-22

PP002...............................UL Dir P201 ..............................B-103 P202 ..............................B-104 P203 ..............................B-117P204 ..............................UL Dir P206 ..............................UL Dir P207 ................................B-92 P210 ..............................UL Dir P211 ..............................UL Dir P213 ................................B-85 P214 ..............................B-105 P215 ..............................UL Dir P216 ..............................UL Dir P217 ..............................UL Dir P224 ..............................UL Dir P225 ..............................UL Dir P227 ..............................UL Dir P228 ..............................B-106 P229 ..............................B-107 P230 ................................B-93 P231 ..............................UL Dir P235 ..............................B-108P237 ................................B-86 P238 ..............................B-109 P239 ................................B-94 P240 ..............................UL Dir P241 ................................B-87 P242 ................................B-95 P244 ..............................B-110 P245 ..............................B-111 P246 ..............................B-113 P251 ..............................UL Dir P253 ..............................UL Dir P254 ..............................B-112 P255 ..............................B-114 P257 ..............................B-115 P259 ..............................UL Dir P260 ..............................UL Dir P261 ..............................UL Dir P262 ..............................UL Dir P267 ..............................B-116P268 ................................B-96 P269 ................................B-97 P501.............................UL DirP502.............................UL DirP503.............................UL DirP504.............................UL Dir

UL Des. No. Ref.

P505.............................UL DirP506.............................UL DirP507.............................UL DirP508.............................UL DirP509.............................UL DirP510 ................................B-2P512.............................UL DirP513.............................UL DirP514.............................UL DirP515.....................B-19, B-20P516.............................UL DirP517.............................UL DirP518.............................UL DirP519.............................UL DirP521 ..............................B-21P522 ..............................B-57P523 ..............................B-22P524 ..............................B-20P525 ..............................B-21P526 ..............................B-22P527 ..............................B-21P528 ..............................B-22P529 ..............................B-21P530 ..............................B-22P676.............................UL DirP711.............................UL DirP713.............................UL DirP714.............................UL DirP717.............................UL DirP719.............................UL DirP722.............................UL DirP724.............................UL DirP728.............................UL DirP739.............................UL DirP740.............................UL DirP803.............................UL DirP807.............................UL DirP826.............................UL DirP904.............................UL DirP909.............................UL DirP912.............................UL DirP915.............................UL Dir

RR5429-1.........................B-31

UU017.............................UL DirU023.............................UL DirU026.............................UL DirU032.............................UL DirU033.............................UL DirU204.............................UL DirU301 ......................A-99, D-8U302 ................................D-9U303 ..................A-113, D-19U304.............................UL DirU305 ...........A-93, A-95, D-22U307 ..............................A-95U308 ....................A-114, D-4U314 ....................A-95, D-22U317 ..............................A-92U320.............................UL DirU321.............................UL DirU322.............................UL DirU323.............................UL DirU324.............................UL DirU325.............................UL DirU326.............................UL DirU327 ..............................A-98U329 ..................A-112, D-21U330..............................D-20U332.............................UL DirU333.............................UL DirU334.................A-100, A-101U335.............................UL DirU336.....................A-63, A-64U338.............................UL DirU339.............................UL DirU340 ............................A-102U341.............................UL DirU342 ............................A-103U344.............................UL DirU345.............................UL DirU346.............................UL DirU348.............................UL DirU349.............................UL DirU350.............................UL DirU351.............................UL DirU353.............................UL DirU354.............................UL DirU355.............................UL DirU359.............................UL Dir

UL Des. No. Ref.

U402.............................UL DirU404 ............A-4, A-18, A-37,

A-85, A-87. D-7, D-23U405 ..............................A-13U406 ..............................A-67U407 .............A-5, A-38, A-86U408 ..............................A-61U410.............................UL DirU411 .............A-20, A-22, D-2U412.....................A-19, A-46U415 ..........A-50, A-51, A-52,

A-53, A-54, A-55, A-58, A-59, A-62, A-91

U416 ..............................A-71U418.............................UL DirU419 ................A-1, A-6, A-8,

A-14, A-16, A-19, A-20, A-21, A-22, A-23, A-24,A-26, A-27, A-28, A-29.

A-30, A-31, D-2, D-12, D-17U420 ...........A-44, A-46, A-47U421.............................UL DirU422.............................UL DirU423....................A-32, A-33,

A-34, A-40, A-41, D-3D-10, D-11, D-24

U424..............................D-11U425 ...........A-32, A-33, A-39

A-40, D-3, D-10, D-11, D-24U426 ..............................A-42U427.....................A-69, A-70U432.............................UL DirU435 ...........A-26, A-27, A-30U436.....................A-48, A-49U438 ..............................A-53U439.............................UL DirU440 ..............................A-34U442 ....................A-79, D-14U443 ..............................A-82U444 ..............................A-90U445 ..............................A-88U446.............................UL DirU448.........................A-6, A-8U449.............................UL DirU451 ...........A-14, A-15, A-16U452 ..............................A-17U453 ..............................A-24U454 ..............................A-25U455.....................A-28, A-29U456.............................UL DirU457 ....................A-80, D-15U458 ....................A-89, D-16U459.....................A-51, A-91U460.............................UL DirU465 ......................A-1, D-17U466.............................UL DirU467 ..............................A-54U468.............................UL DirU469 ..............................A-50U472.............................UL DirU473 ...........A-35, A-83, D-18U474 ......................A-81, D-1U475.............................UL DirU476 ..............................A-78U477.............................UL DirU478.............................UL DirU484 ..............................A-77U485.....................A-36, A-84U488 ..............................A-75U489.............................UL DirU490.....................A-31, A-43U491 ..............................A-23U492 ..............................A-52U493.............................UL DirU495.............................UL DirU496 ..............................A-15U497.............................UL DirU504.............................UL DirU505.............................UL DirU506.............................UL DirU507.............................UL DirU512.............................UL DirU513.............................UL DirU526.............................UL DirU528.............................UL DirU529 ..............................A-56U601.............................UL DirU602.............................UL DirU603.............................UL DirU604.............................UL DirU605.............................UL DirU606.............................UL DirU608.............................UL Dir

UL Des. No. Ref.

U609.............................UL DirU611.............................UL DirU613.............................UL DirU615.............................UL DirU617.............................UL DirU618.............................UL DirU619.............................UL DirU620.............................UL DirU622.............................UL DirU623.............................UL DirU625.............................UL DirU626.............................UL DirU627.............................UL DirU633.............................UL DirU634.............................UL DirU635.............................UL DirU637.............................UL DirU639.............................UL DirU640.............................UL DirU642.............................UL DirU643.............................UL DirU645.............................UL DirU647.............................UL DirU805 ..............................A-45U910 ..............................A-73U912.............................UL DirU914 ..............................A-72

VV402.............................UL DirV403.............................UL DirV404.............................UL DirV405.............................UL DirV409.............................UL DirV410.............................UL DirV411.............................UL DirV413.............................UL DirV414.............................UL DirV415.............................UL Dir

W-J W-J-1091 ........F-16, F-38, F-56 W-J-2068 ..........................F-91

W-L W-L-1027 ................F-17, F-18,

F-39, F-57 W-L-1039 .......F-19, F-40, F-58 W-L-1063 .......F-20, F-41, F-59 W-L-1064 .................F-21, F-42 W-L-1065 .................F-22, F-43 W-L-1087 .......F-23, F-44, F-60 W-L-2220 ..........................F-92 W-L-2221 ..........................F-93 W-L-2222 ..........................F-94 W-L-2223 ..........................F-95 W-L-2224 ..........................F-96 W-L-2225 ..........................F-97 W-L-2226 ..........................F-98 W-L-2227...........................F-78W-L-3023 ..........................F-69 W-L-3034 ..........................F-70 W-L-3162 ..........................F-71 W-L-3163 ..........................F-72 W-L-5043 .................F-24, F-61 W-L-5044 .................F-25, F-62 W-L-5114 .................F-26, F-63 W-L-5115 .................F-27, F-64 W-L-5116 ..........................F-28 W-L-7001 ..........................F-75 W-L-7002 ..........................F-76 W-L-7057 ..........................F-77

XX402 .............C-4, C-10, C-18X405 ................................C-3X502.............................UL DirX504.............................UL DirX507.........................C-1, C-2X508.............................UL DirX514.........................C-6, C-7X515.........................C-8, C-9X516.............................UL DirX518.....................C-14, C-15X521.....................C-12, C-13X522.............................UL DirX523.............................UL DirX524.....................C-16, C-17X526.............................UL DirX527.............................UL DirX528 ........................C-5, C11X530.............................UL DirX531.............................UL Dir

SA100/USG Corporation 5

Index to UL DesignsThis Index lists all UL Designs that involve the products of the United StatesGypsum Company and USG Interiors, Inc. UL Design numbers appear with theircorresponding references, the UL Fire Resistance Directory, or the Construction

Selector section letter and number. For example, UL Design D215 is referencedto B-67, that is, test no. 67 in Section B of the Construction Selector; UL DesignD216 is not in the Construction Selector but is described in the UL Directory.

Page 6: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Partitions

Selector Guide to Sound-Rated Partitions(1)

STC range 60-69 55-59 50-54 45-49

Drywall or 24, 25, 28, 29, 30, 11, 14, 16, 17, 19 1, 8, 13, 14, 19, 21, 1, 3, 6, 7, 9, 10, 12,Veneer Plaster 34, 64, 88, 89 20, 21, 24, 25, 26, 23, 34, 44, 47, 52, 19, 20, 32, 39, 40,

31, 46, 47, 64, 82 55, 62, 64, 71, 79, 53, 54, 64, 65, 66,89, 100, 104, 105, 96, 98, 101, 106, 109, 69, 79, 80, 95, 96,108, 109 110, 115 100, 107, 110

(1) Assemblies are identified by numbers in right outside margin, 1 to 115

, pages 6 through 16.

Notes on Using This Selector Guide 1. Two recent tests permit SHEETROCK Brand Gypsum Panel products and IMPERIAL Brand Gypsum Base products to be applied horizontally or vertically in partitions without compromising the fire rating. These tests areUL Design U419 for non-load-bearing partitions and UL Design U423 for load-bearing partitions. When either of these tests are listed with a USG system, it means that the system can now be built with the panelsoriented in either direction. 2. The two fire tests indicated above also demonstrated that when FIRECODE or FIRECODE C Core products are used, the horizontal joints on opposite side of the studs need not be staggered (as was previously required). 3. In partitions indicating the use of 1/2� DUROCK Brand Cement Board, it is permissible to substitute 5/8� DUROCK Brand Cement Board without compromising the fire rating. 4. In partitions indicating the use of 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, it is permissible to substitute 5/8” FIBEROCK Brand Abuse-Resistant Panels without compromising the fire rating. 5. Note that in partitions indicating the use of SHEETROCK Brand Exterior Sheathing or DUROCK Brand Cement Panels for sheathing applications, it is permissible to substitute 5/8� FIBEROCK Brand Sheathing withoutcompromising the fire rating. 6. Where thermal insulation is shown in assembly drawings, the specific product is required to achieve the stated fire rating. Glass fiber insulation cannot be substituted for mineral wool insulation. 7. In fire-rated non-load-bearing partitions, steel studs should not be attached to ceiling runners. 8. For specific information regarding the assemblies shown in this folder, consult the current UL Fire Resistance Directory.9. In multi-layer applications, only the joints of the face layer need be finished.

DetailsIn details, shaded backgrounds designate materials indicated below:

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer PlasterSteel Stud Partitions (Non-Load-Bearing) – 1-Hour Ratingwt. 6 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or IMPERIAL Brand 40 USG-860808 SA700 1

Abuse-Resistant Gypsum Base, FIRECODE Core—3-5/8� 25 ga steel studs 49 Based on 3� SAFB in cavity panels— SA70724� o.c.—panels screw att—joints fin—perimeter caulked—UL Des U419 SA-870717 SA923or U465—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE 51 Based on FIRECODE C Core panels and 3�Core, and veneer finish surface SAFB 25� wide, creased to fit

cavity—RAL-TL-90-166

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core— 1-5/8� 25 ga steel 38 USG-860809 SA923 2studs24� o.c.,single layer panels vert appl & screw att 12� o.c.—joints fin—

wt. 5 perimeter caulked—U of C 7-31-62

veneer plaster only (not drywall) 1/2� IMPERIAL Brand Gypsum Base, FIRECODE C 45 Based on 3-5/8� studs 24� o.c. with 1� SAFB in SA920 3Core, & veneer finish—2-1/2� 25 ga steel studs—base screw att— joints stag & cavity—CK-664-1taped—1/16� veneer finish—perimeter caulked—stud spacing at 16�recommended—GA-WP-1240

wt. 8

3-1/2� 20 ga. steel studs 16 o.c.—5/8� IMPERIAL Brand Gypsum Base, FIRECODE SA920 4Core, one side—DUROCK Brand cement board other side—gypsum panels and cement board screw-attached to studs—3� SAFB—USG Plaster Bonder overcement board and treated joints—joints treated with USG setting- type jointcompound and paper tape—Diamond Brand veneer basecoat with IMPERIAL Brand

wt.7 finish—UL Des U404

5/8� DUROCK or 5/8� IMPERIAL Brand FIRECODE Base—3-1/2� 20 ga. studs— SA920 53� THERMAFIBER SAFB—board screw-attached 8� o.c. with 1-5/8� DUROCK screws—USG Plaster Bonder over untreated joint areas—joints treated with USG setting-type joint compound and paper tape—USG Plaster Bonder over cement board and treated joints—Diamond Brand veneer basecoat with veneer or conventional finish—UL Des U407

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—2-1/2� studs 45 RAL-TL-69-42 SA923 624� o.c.—single layer panels ea side screw att—1-1/2� SAFB— 48 Based on 3-5/8� studs & 2� SAFB—SA-800422joints fin—perimeter caulked—UL Des U419 or U448—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 5

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core— 2-1/2� 25 ga steel 47 SA-831001 SA923 7studs 24� o.c.—1-1/2� SAFB—panels apply horiz & screw-att—horiz joints fin—CEG 8-11-83—rating also applies to assembly with 1/2� SHEETROCKBrand Gypsum Panels, FIRECODE C Core, panels and joints fin—CEG 5-9-84—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE Core, and

wt. 6 veneer finish surface

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—2-1/2� 25 ga steel 50 SA-800504 SA923 8studs 24� o.c.—single layer panels one side screw att—1-1/2� SAFB— 41 Based on same construction without double layers opp side—panels screw att—joints fin—perimeter caulked— SAFB—RAL-TL-69-148UL Des U419 or U448—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 7

��������������4"�������

�������33⁄4"

�������

�������31⁄2"�������

��������������

43⁄4"

��������������

�����������

����������������

45⁄8"

�������35⁄8"�������

�������47⁄8"27⁄8"�������

6

A

Furring channels.RC-1™ Resilient Channels or equivalent.

Sound-deadening material; column or beam fireproofing.

Page 7: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Steel Stud Partitions (Non-Load-Bearing) – 1-Hour Rating

Face layter 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw att— 53 Based on 1-1/2� SAFB & 2-1/2� studs—CK-684-13 SA923 91-5/8� 25 ga steel studs 24� o.c.—base layer 1/4� SHEETROCK Brand Gypsum Panels, screw att—joints fin—perimeter caulked—GA-WP-1090—ratingalso applies with IMPERIAL Brand gypsum Base, FIRECODE C Core, and veneerfinish surface

Alternate based on 2-1/2� 25 ga steel studs & 1/2� face layer laminated— 53 Based on 2� glass fiber—NGC-2318 SA923 10GA-WP-1051

Alternate based on 2-1/2� 25 ga steel studs & face layer of 5/8� SHEETROCK Brand 55 Based on 1-1/2� SAFB—CK-684-14 SA923 11Gypsum Panels, FIRECODE Core —GA-WP-1015

Alternate based on 2-1/2� 25 ga steel studs & base layer of 3/8� SHEETROCK Brand 54 Based on 2� glass fiber—CK-8104.02 SA923 12wt. 7 Gypsum Panels—GA-WP-1053

5/8� SHEETROCK Brand Vinyl-Faced Gypsum Panels, FIRECODE Core—2-1/2� 45 G&H NG-146FT SA928 13steel studs 24� o.c. with battens screw att to each stud—aluminum battens Based on 3� insulationover tracks—UL Des U405

wt. 5

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3-5/8� 25 ga steel 50 RAL-TL-87-156 (42 MTC) SA707 14studs 24� o.c.—3� SAFB—RC-1 chan or equiv one side spaced 24� o.c., screw- 54 Based on 5/8� thick panels— SA920att to studs—gypsum panels screw-att to studs & RC-1 chan or equiv—joints fin— RAL-TL-83-216 (47 MTC) SA923perimeter caulked—UL Des U419 or U451—rating also applies with IMPERIAL 55 Based on 5/8� IMPERIAL Brand Gypsum Base,Brand Gypsum Base, FIRECODE C Core, and veneer finish surface FIRECODE Core, & creased 3� SAFB—SA-860635

55 Based on 5/8� SHEETROCK Brand GypsumPanels, FIRECODE Core, & on 25� widecreased SAFB—SA-850415

54 Based on 5/8� SHEETROCK Brand Gypsumwt. 6 Panels, FIRECODE Core—USG-850409

3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE Core—1-5/8� studs SA923 1524� o.c.—panels screw att —joints stag & fin—UL Des U496 or U451—UL Des U451 has panels applied over RC-1 chan or equiv one side

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—6� 20 ga steel studs 56 RAL-TL-87-139 (48 MTC) SA923 1624� o.c.—5� SAFB—RC-1 chan or equiv one side spaced 24� o.c., screw- 56 Based on 5/8� thick SHEETROCK Brandatt to studs—gypsum panels screw-att to studs & RC-1 chan or equiv— Gypsum Panels, FIRECODE C Core—joints stag and fin—perimeter caulked—UL Des U419 or U451 RAL-TL-84-141(50 MTC)

wt. 6

Steel Stud Partition (Non-Load-Bearing) – 1-1/2-hour Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3-5/8� 20 ga 58 RAL-TL-83-215 (52 MTC) SA920 17studs 24� o.c.—3� SAFB—RC-1 chan or equiv one side spaced 24� o.c., 59 8-3/8� wall with 6� 20 ga struc studs & SA923screw-attto studs—2 layers gypsum panels screw-att to studs, 1 layer screw-att 5� SAFB—RAL-TL-84-140 (54 MTC)to chan—face layer joints fin—perimeter caulked—UL U452—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finishsurface

wt. 8

Steel Stud Partitions (Non-Load-Bearing) – 2-Hour Rating3-1/2� 20 ga. steel studs 16� o.c.—double-layer 5/8� IMPERIAL Brand FIRECODE Base SA920 18one side—DUROCK Brand Cement Board face layer, 5/8� SHEETROCK Brand gypsum sheathing, FIRECODE Core, base layer other side—gypsum panels and cementboard screw-attached to studs—3� SAFB—USG Plaster Bonder over CementBoard and treated joints—face layer joints treated with USG setting-type jointcompound and paper tape—DIAMOND Brand veneer basecoat with IMPERIAL Brand

wt. 11 finish—UL Des U404

Double layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 50 Based on 3-5/8� stud assembly without SA707 19ea side—1-5/8� 25 ga steel studs 24� o.c.—joints stag—base layer screw att— SAFB—USG-840817 SA920face layer strip lamin or screw att—face layer joints fin—perim caulked— 55 Based on 3-5/8� studs and 1-1/22� SA923UL Des U412 or U419—rating also applies with IMPERIAL Brand Gypsum Base, SAFB—SA-800421FIRECODE C Core, and veneer finish surface 52 Based on lamin. face layer, 1-1/2� SAFB and

2-1/2� studs —SA-86093254 Based on 2-1/2� studs, screw-att face layer and

wt. 10 1-1/2� SAFB—CK-654-40

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, plain 48 Based on 3-5/8� studs and SA920 20or vinyl faced appl ea side—1-5/8� steel studs 24� o.c.— base layers screw 5/8� SHEETROCK Brand Gypsum SA923att—face layer lamin or screw att—face layer joints fin—perimeter caulked— Panels, FIRECODE C UL Des U411 or U419—rating also applies with IMPERIAL Brand Gypsum Core—BBN-770408Base, FIRECODE or FIRECODE C Core, and veneer finish surface 56 Based on 3-5/8� studs and

3� SAFB—USG-840818

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or 51 Based on 2-1/2� SAFB in SA923 21SHEETROCK Brand Abuse-Resistant Gypsum Panels, FIRECODE Core, or cavity—GA-WP-1548IMPERIAL Brand Abuse-Resistant Gypsum Base, FIRECODE Core, ea side, 2-1/2� 56 Based on 2� SAFB in 25 ga steel studs 24� o.c.—joints stag—base and face layers screw att— cavity—USG-840819joints fin—perimeter caulked—UL Des U419—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish

wt 12 surface

�������

���������������������41⁄8"

61⁄8"

�������

����������������������������35⁄8"41⁄2"55⁄8"

�����������

��������������������������������

57⁄8",

����������������

��������������

��������������

��������������

6"

��������������

71⁄2"��������������

�������

�������35⁄8"

51⁄8"��������������

��������������

�������33⁄4"

�������

����������������������������

31⁄8"

���������������������

SA100/USG Corporation 7

A

Page 8: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

8

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Steel Stud Partitions (Non-Load-Bearing) – 2-Hour Rating

Double layer 5/8� SHEETROCK Vinyl-Faced Gypsum Panels, FIRECODE Core— SA928 222-1/2� 25 ga steel studs 24� o.c.— panels screw att—UL Des U411 or U419

wt 10

3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE Core, ea. side—min. 50 USG-910617 SA707 233-1/2� 25 ga steel studs 24� o.c.—3� SAFB—panels screw att— SA923joints stag & fin—perimeter caulked—UL Des U419 or U491

wt. 7

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3-5/8� 20 ga 60 Based on1/2� thick panels, 6� 20 ga struc SA923 24studs 24� o.c.—3� SAFB—RC-1 chan or equiv one side spaced studs, 5� SAFB—RAL-TL-87-140 (54 MTC)24� o.c., screw-att to studs—single-layer gypsum panels screw-att to studs, 59 Based on 5/8� thick panels, 6� 20 ga struc double layer screw-att to chan—face layer joints fin—perimeter caulked— studs, 5� SAFB—RAL-TL-84-136 (54 MTC)UL Des U419 or U453

wt. 9

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—2-1/2� 25 ga steel 60 RAL-TL-87-154 (54 MTC) SA923 25studs 24� o.c.—min. 1� SAFB—RC-1 chan or equiv one side, spaced 24� o.c. 61 Based on 5/8� thick panels—screw-att to studs—double layer gypsum panels screw-att to chan, 2 layers RAL-TL-83-214 (57 MTC)screw-att to steel studs—face layer joints fin—perimeter caulked— 57 Based on 5/8� thick panels—USG-871207UL Des U454 63 Based on 6� 20 ga struc studs & 5� SAFB—

RAL-TL-87-141 (59 MTC)62 Based on 5/8� thick panels, 6� 20 ga struc studs

wt. 10 & 5� SAFB—RAL-TL-84-139 (58 MTC)

Steel Stud Partitions (Non-Load-Bearing) – 3-Hour Rating3 layers 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ea side— 59 Based on assembly with 1-1/2� SAFB in SA920 261-5/8� 25 ga steel studs 24� o.c.—panels screw-att with face layer joints fin— cavity—SA-830112 SA923perimeter caulked—rating based on assembly with or without sound atten fire blankets—UL Des U419 or U435—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 13

Steel stud—Double layer 3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE SA923 27Core, ea side—1-5/8� 25 ga steel studs 24� o.c.—Panels screw att with face layer joints fin—perimeter caulked—UL Des U419 or U435—rating also applies with IMPERIAL Brand Base, ULTRACODE Core, and veneer finish surface

Resil Stud Drywall—1/2� SHEETROCK Brand Gypsum Panels, FIRECODE 61 RAL-TL-87-153 (56 MTC)Based on SA707 28C Core—3-5/8� 20 ga studs 24� o.c.—3� SAFB—RC-1 chan or equiv one side, 62 5/8� thick panels—RAL-TL-83-213 (59 MTC) SA920spaced 24� o.c. screw-att to studs—3 layers gypsum panels screw-att 64 Based on 6� 20 ga struc studs & 5� SAFB— SA923to studs, double layer screw-att to chan—face layer joints fin —perimeter RAL-TL-87-142 (59 MTC)caulked—UL Des U419 or U455 63 Based on 5/8� thick panels, 6� 20 ga struc

studs & 5� SAFB—RAL-TL-84-138 (59 MTC)65 Based on 5/8� thick panels, 6� 20 ga struc studs,

5� SAFB, acoustical sealant bead between panels and studs, dabs 8� o.c. between panel layers on stud

wt. 12 side—RAL-TL-84-150 (60 MTC)

Resil Stud Drywall—1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C 63 RAL-TL-87-152 (58 MTC) SA923 29Core—3-5/8� 20 ga studs 24� o.c.—3� SAFB—RC-1 chan or equiv one 65 6� 20 ga struc studs, 5� SAFBside, spaced 24� o.c. screw-att to studs—3 layers gypsum panels screw-att RAL-TL-87-143 (61 MTC)to studs, 3 layers screw-att to chan—face layer joints fin— perimetercaulked—UL Des U419 or U455

wt. 14

Steel Stud Partitions (Non-Load-Bearing) – 4-Hour RatingSteel Stud—4 layers 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 62 Based on assembly with 1-1/2� SAFB in SA920 30ea side—1-5/8� 25 ga steel studs 24� o.c.—panels screw att with face layer cavity—SA-830113 SA923 joints fin—perimeter caulked—UL Des U419 or U435—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 17

Steel Stud—2 layers 3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE 56 SA-910907 SA707 31Core, ea side—2-1/2� 25 ga steel studs 24� o.c.—2� SAFB—panels screw att SA923with face layer joints fin—UL Des U419 or U490

wt. 11

Steel Stud Partition (Load-Bearing) – 45-Minute Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3-1/2� 20 ga steel 47 Based on 3� SAFB in cavity—SA-861001 SA923 32studs 24� o.c.—panels screw att—joints fin—UL Des U423 or U425—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 6

�������41⁄2"

�������

��������������51⁄2" ������� �������

�������

����������������������������55⁄8"���������������������

��������������

����������������������������

��������������

71⁄8"��������������

��������������

����������������������������

��������������

65⁄8"��������������

��������������

��������������

��������������

45⁄8"

���������������������45⁄8"���������������������

��������������

�������5"�������

��������������

��������������

��������������

��������������

6"

�������5"�������

��������������

��������������5"

A

Page 9: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 9

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Steel Stud Partition (Load-Bearing) – 1 hour Rating

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—3-1/2� 20 ga steel 40 USG-810519 SA923 33studs 24� o.c.—panels screw att —joints fin—UL Des U423 or U425—rating 41 Based on 2� SAFB in cavity—USG-810518also applies with IMPERIAL Brand Gypsum Base, FIRECODE Core, and veneerfinish surface

wt. 6

Doublel layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— 61 Based on 3-1/2� 16 ga struc studs, 5/8� thick SA923 343-1/2� 20 ga steel studs 24� o.c.—SAFB optional—RC-1 chan panels, lateral bracing and 3� SAFB—SA-830628or equiv one side, spaced 24� o.c. screw-att to studs—panels screw att to 51 Based on 3-1/2� 16 ga struc studs and lateral chan one side, to studs other side—face layer joints fin—UL Des U423 or U440 bracing—SA-840715—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core,and veneer finish surface

wt. 10

Face layer 1/2� DUROCK Brand Cement Board—base layer 5/8� SHEETROCK Brand N/A SA932 35Gypsum Panels or sheathing, FIRECODE Core—min. 3-1/2�, 20 ga struc studs 16� o.c.—3� SAFB—panels screw att—UL Des U473—rating also applies withIMPERIAL Brand Gypsum Base, FIRECODE Core, and veneer finish surface

wt. 9

Face layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—base layer N/A SA932 361/2� DUROCK Brand Cement Board—panel screw att—min. 3-1/2� 20 ga struc studs 16� o.c.—3� SAFB—UL Des U485—rating also applies with IMPERIALBrand Gypsum Base, FIRECODE Core, and veneer finish surface

1/2� DUROCK Brand cement panel—3-1/2 studs 16� o.c.—3� SAFB— N/A SA932 37joints taped and treated—5/8� SHEETROCK Brand Gypsum Panels, FIRECODECore, other side—panels screw att—UL Des U404

wt. 7

5/8� DUROCK Brand cement panel and 1/4� ceramic tile (or DUROSCREEN 1100 or N/A SA932 38USG veneer plaster system)—3-1/2� studs 16� o.c.—3� SAFB—panels screw att—UL Des U407

Steel Stud Partitions (Load-Bearing) – 1-1/2-hour RatingDouble layer 1/2� SHEETROCK Brand gypsum panels, FIRECODE C Core— 49 Based on 2� SAFB—USG-811009 SA923 393-1/2� 20 ga steel studs 24� o.c.—panels screw att—face layer joints fin— 49 Based on 2� SAFB and 6� 20 ga strucUL Des U425 studs—USG-810940

wt. 9

Steel Stud Partitions (Load-Bearing) – 2-hour RatingDouble layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core— 48 Based on 2� SAFB in cavity—USG-811006 SA923 403-1/2� 20 ga steel studs 24� o.c.—panels screw att—face layer joints fin— 49 Based on 2� SAFB and 6� 20 ga strucload-bearing up to 100% allowable stud axial load when min 2� stud—USG-810937Thermafiber SAFB is used in stud cavities; otherwise load-bearing upto 80% allowable steel axial load—UL Des U423 or U425

Alternate based on three layers 1/2� SHEETROCK Brand Gypsum Panels,FIRECODE C SA923 41wt.10 Core each side—load bearing up to 100% allowable stud axial load—UL Des U423

Steel Stud Partition (Load-Bearing) – 3-hour RatingFour layers 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ea side— N/A SA923 423-1/2� 20 ga steel studs 24� o.c.—panels screw att—face layer joints fin—load-bearing up to 100% allowable stud axial load—UL Des U426—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core,and veneer finish surface

wt. 18

Double layer 3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE Core—3-1/2� SA923 4320 ga. structural studs 24� o.c.—3� SAFB—face layer joints fin—UL Des U490

Steel Stud Double Wall Chases – 1-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, ea side— 52 Based on 3-1/2� insulation one side— SA923 441-5/8� 25 ga steel studs 24� o.c. in 2 rows —5/8� gypsum panel gussets RAL-TL-76-155or steel run braces spanning chase screw-att to studs—panels screw att—joints fin—UL Des U420

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core,ea side—fireproofed N/A SA923 45steel truss—2-1/2� 25 ga steel studs 24� o.c. in 2 rows spaced 8� apart—5/8�gypsum panel gussets spanning chase att to stud at qtr & ctr points—panels screw-att—joints fin—includes 3 hr. truss—UL Des U805

��������������

43⁄4"141⁄4"���������������

��

��������������61⁄2" ������� �������

��������������

����������������������������71⁄2"

��������������

��������������

6"�������

��������������

�������

��������������51⁄2"

�������

�������������������5" �������� �����������

�����������

����������������

45⁄8",43⁄4"

�����������

����������������

�����������

����������������

53⁄4"

�����������

����������������51⁄4"

����������������

����������������������������

����������������������������

6"

��������������

43⁄4"

��������������

A

Page 10: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

10

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Steel Stud Double Wall Chases – 2-Hour Ratingwt. 11 Double layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ea side— 55 SA-860907 SA923 46

1-5/8� 25 ga steel studs 24� o.c. in 2 rows spaced 5-3/4� apart—1/2� gypsum panel gussets spanning chase att to studs at qtr points—panels screw att—face layer joints fin—perimeter caulked—est. fire rating based on UL Des U412 and U420

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, ea side— 52 RAL-TL-76-162 SA923 471-5/8� 25 ga steel studs 24� o.c. in 2 rows spaced 6-1/4� apart—5/8� gypsum 57 Based on 3-1/2� insulation one side—panel gussets or stl run braces spanning chase screw-att to studs—panels appl RAL-TL-76-156

wt. 12 screw att—face layer joints fin—UL Des U420

Steel Stud Double Wall Chases – 3-Hour Rating3 layers 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE N/A SA923 48C Core, ea side—1-5/8� studs 24� o.c. in 2 rows spaced 3� apart—steel truss member—gypsum panel gussets or stl run braces spanning chase screw-att to studs—panels screw att—face layer joints fin—2 hr. rating applies with 2 layers panels ea side—1 hr. rating applies with single layer 5/8� panels ea side—UL Des U436

wt. 13

Double layer 3/4� SHEETROCK Brand Gypsum Panels, ULTRACODE Core, ea side— SA923 491-5/8� studs 24� o.c. in two rows spaced 2� apart—steel truss member—gypsum panel gussets or stl run braces spanning chase screw-att to studs—panels screw att—face layer joints fin—UL Des U436

Cavity Shaft Wall System – 1-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, one side — N/A SA926 501� SHEETROCK Brand Gypsum Liner Panels set betw USG steel C-H studs 24� o.c.—joints fin—UL Des U415 or U469—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE Core, and veneer finish surface and/or SAFB in cavity

wt. 8

Shaft Wall System – 2-Hour Rating1/2� DUROCK Brand Cement Board—5/8� SHEETROCK Brand Gypsum Panels, N/A SA926 51FIRECODE Core—1� SHEETROCK Brand Gypsum Liner Panels set betw USG steel 20 ga.min C-H studs 24� o.c.—1-1/2� SAFB—Cement Board screw att & laminated to gypsum panel with 4� strip ceramic tile mastic—cement board joints fin—UL Des U415 or U459

1� SHEETROCK Brand Gypsum Liner Panels, set betw 4�USG steel C-H studs 52 SA-910913 SA707 5224� o.c. one side—3/4� SHEETROCK Brand gypsum panels, ULTRACODE Core, SA923other side—3� SAFB—joints fin—perimeter caulked— SA926UL Des U415 or U492

wt. 8

Double layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 39 USG-750302 SA926 53one side—1� SHEETROCK Brand liner panels set betw USG 25 ga. steel 47 Based on 1� SAFB in cavity—BBN-750706C-H studs 24� o.c.—face layer joints fin—UL Des U415 or U438—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer

wt. 9 finish surface

1/2� SHEETROCK Brand gypsum panels, FIRECODE C Core, one side—1� SHEETROCK 47 Based on 1� SAFB in cavity—BBN-750704 SA926 54Brand gypsum liner Panels set betw USG steel C-H studs 24� o.c. and 1/2� SA925SHEETROCK BrandGypsum Panels, FIRECODE C Core, other side—joints fin—UL Des U415 or U467—rating also applies with IMPERIAL Brand gypsum base, FIRECODE C Core, and veneer finish surface

wt. 9

31⁄2"

���������������������

��������

��������

31⁄2"��������������

��������

��������

�������43⁄4"

��������

��������

�����������������������������

��������

��������35⁄8"

�������31⁄8"

��������

��������

����������������������������

��������������

81⁄4"

���

���

��������������

��������������

��������������

91⁄4"

����������������������������

���

���

����������������������������

����������������������������

11"12"

���

���

����������������������������

A

Page 11: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 11

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Shaft Wall Systems – 2-Hour Rating

Double layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 51 Based on 1-1/2� SAFB in cavity—BBN-750412 SA926 55one side—1� SHEETROCK Brand Gypsum Liner Panels set betw USG 25 ga. steel C-H studs 24� o.c—RC-1 chan or equiv spaced 24� o.c.—panels & RC-1 chan screw-att to side opp liner panels—face layer appl vert—joints fin—UL Des U415—rating also applies with IMPERIAL Brand Gypsum Base,

wt. 10 FIRECODE C Core, and veneer finish surface

Vent Shaft Gypsum Drywall—1-5/8� steel runners—25 ga. steel angles— SA926 561/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—1� SHEETROCKBrand Gypsum Liner Panel—UL Des U529

2� Laminated Solid—double layer 1� SHEETROCK Brand Gypsum Liner Panels N/A 57laminated—2�x1� 25 ga. channels back to back & welded 24� o.c.—2 layers, 1/2� SHEETROCK Brand Gypsum Panels screw att—joints stag—OSU T-4481

Shaft Wall Systems – 3-Hour Rating3 layers 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, one side— N/A 58face layer joints fin—1� SHEETROCK Brand Gypsum Liner Panels set between USG 25 ga. steel C-H studs 24� o.c., other side—rating also applies with IMPERIAL BrandFIRECODE C Base and veneer finish surface or SAFB in cavity—UL Des U415

3 Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, one side— N/A 591� SHEETROCK Brand Gypsum Liner Panels set between USG 25 ga. steel C-H studs 24� o.c. and 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, other side—face layer joints fin—rating also applies with IMPERIAL Brand FIRECODE C Base and veneer finish surface or SAFB in cavity—UL Des U415

Shaft Wall—double layer 1� SHEETROCK Brand Gypsum Liner Panels laminated— N/A 602�x1� 25 ga. channels back to back & welded 24� o.c.—face & base layer of5/8� SHEETROCK Brand Gypsum Panels, furring channel 24� o.c., joints stag—OSU-T-4423—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODEor FIRECODE C Core, and veneer finish surface

Cavity Shaft Wall System – 4-Hour Rating1� SHEETROCK Brand Gypsum Liner Panelsset betw USG 25 ga. steel N/A SA926 61C-H studs 24� o.c.—2 layers SHEETROCK Brand Gypsum Panels, ULTRACODE Core, furring channel 24� o.c., 2 layers SHEETROCK Brand Gypsum Panels, ULTRACODECore—face layer joints fin UL Des U408

wt. 16

Area Separation Wall Systems – 2-Hour Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—1� SHEETROCK 50 Based on 1-1/2� SAFB in cavity—BBN-750411 SA925 62Brand Gypsum Liner Panels set in USG 25 ga. steel C-H studs 24� o.c.—RC-1 chan or equiv 24� o.c. screw att to side opp liner panels—single layer panels ea side screw att—joints fin—perim caulked—UL Des U415—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

wt. 10

Solid Area Separation Wall—two 1� SHEETROCK Brand Gypsum Liner N/A SA925 63Panels set in USG H-studs 24� o.c.—min. 3/4� air space both sides separating liner panels from any adjacent construction—UL Des U336

Solid Area Separation Wall—two 1� SHEETROCK Brand Gypsum Liner Panels 54 RAL-TL-88-348 SA925 64set in USG H-studs 24 o.c.—wd or steel studs each side min 3/4� from liner 46 Based on 2� SAFB on one side—RAL-TL-88-353panels—1/2� SHEETROCK Brand Gypsum Panels—UL Des U336 58 Based on 2x4s and 2� SAFB on both

sides—RAL-TL-88-34757 Based on 2x4s and 3� SAFB one

side—RAL-TL-88-35160 Based on 2x4s and 3� SAFB on both

sides—RAL-TL-88-35045 Based on 2x3s, 5/8� gypsum panels, no

SAFB—BBN-73010454 Based on 2x3s, 5/8� gypsum panels, 2� SAFB

one side—BBN-73010357 Based on 2x3s, 5/8� gypsum panels, 2� SAFB

both sides—BBN-730102

�������

�������

111⁄2"����������������

��������

31⁄2"����������������

��������

�������

��������

��������4"

��������������

����������������������������

63⁄8"

��������

�������41⁄8" ����������������

���������������

�������

��������������

��������

��������43⁄8"

���������������������

��������

��������

43⁄8"

��������������3" ��������������

2"���������������������

���������������������

��������

��������

4"

A

Page 12: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

12

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Solid Area Separation Wall System – 3-Hour Rating

Relocatable Walls – No RatingRel ULTRAWALL Partn—concealed “T’’ studs both sides 24� o.c.— 48 RAL-TL-70-251 FACTS ON 653/4� x 24� bevel edge ULTRAWALL gypsum panels—1-1/2� SAFB—joints unfin— DEMANDperimeter caulked—N/A 800 874 0306

Systems ULTRAWALL Partn—aluminum H-studs 24� o.c.—steel floor 42 USG-850509 FACTS ON 66runner—ARL-300 ceiling runner—3/4� x 24� bevel edge ULTRAWALL 46 Based on same construction with 1-1/2� DEMANDGypsum Panels—perimeter gaskets—joints finished with vinyl THERMAFIBER SAFB—USG-850510 800 874 0306trim—N/A

Relocatable Walls – 1-Hour Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—alum battens N/A 6724� o.c.—2-1/2� 25 ga steel studs 24� o.c.—2� insulation—UL Des U406

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—alum battens N/A 6824� o.c.—2-1/2� 25 ga steel studs 24� o.c.—2� insulation—U of C 7-27-70

Rel ULTRAWALL Partn—concealed “H’’ studs 24� or 30� o.c.—3/4� x 24� 42 Based on 24� panels—BBN-701008 FACTS ON 69or 30� bevel edge ULTRAWALL gypsum panels—joints unfin—perim 47 Based on 24� panels and 1� THERMAFIBER DEMANDgaskets—based on 24� panels—U of C 8-18-67—based on 30� SAFB in cavity—BBN-701216 800 874 0306panels—UL Des U427

Rel ULTRAWALL Partn—concealed “H’’ studs 24� o.c.—stl flr N/A FACTS ON 70run—painted stl clg run with int tabs—3/4� x 24� bevel edge ULTRAWALL DEMANDgypsum panels—joints unfin—WHI-120/121—based on alum clg 800 874 0306run—UL Des U427

Relocatable Wall – 2-Hour RatingRel ULTRAWALL Partn—concealed “H’’ studs 24� o.c.—1-1/2� SAFB— 50 RAL-TL-70-198 FACTS ON 713/4� x 24� bevel edge panels one side—double layer opp side with DEMAND3/4� Z-runners betw layers—joints unfin—perim caulked—painted— 800 874 0306UL Des U416

Furred Masonry – 3-Hour RatingConcrete Blk (UL Classified)—1/2� SHEETROCK Brand Gypsum Panels, N/A SA920 72FIRECODE C Core, or 1/2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, &veneer finish—7/8� deep met fur chan 24� o.c.—base att with 1� drywall screws 8� o.c. at butt joints, 12� o.c. in field—1/16� veneer finish—joints fin—UL Des U914

Furred Masonry – 4-Hour RatingConcrete Blk (UL Classified)—1/2� SHEETROCK Brand Gypsum Panels, N/A SA920 73FIRECODE C Core, or 1/2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, &veneer finish—7/8� deep met fur chan 24� o.c.—base att with 1� drywall screws 8� o.c. at butt joints, 12� o.c. in field—1/16� veneer finish—joints fin—UL Des U910

Non-Combustible Wall Systems – Conventional Lath & PlasterSteel Stud Partitions – 1-Hour Rating

2� Solid Metal Lath & Plaster—3/4� cr chan 16� o.c.—2.5 lb. metal lath 37 NBS-523 F45 SA920 74wire-tied to chan—100:2-100:2 gypsum sand plaster—OSU-T-129

wt. 18

3/8� Rocklath Type X base, both sides, 8� o.c.—2-1/2� 20 ga steel studs 16� o.c.— N/A 751� THERMAFIBER insulation—7/16� plaster base coat, 1/16� plaster finishcoat—UL Des U488

��������������

���������������������

41⁄4"

�������2"

�������������

101⁄2"

������������

�������

75⁄8" min.

������91⁄8"

������������

�������

75⁄8" min.

��������

43⁄8" ��������

��������

��������

��������

��������

33⁄8" ��������

��������

��������

��������31⁄2"

��������

��������31⁄2"

��������

����33⁄8"

����

��������

��������

��������

������������

����33⁄8" ����

����

A

Page 13: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 12SA100/USG Corporation 13

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Conventional Lath & Plaster (continued)Steel Stud Partitions – 2-Hour Rating

21⁄2� Solid Metal Lath & Plaster—3/4� cr chan 16� o.c.—3.4 lb. metal lath N/A 76wire-tied to chan—1:2-1:3 gypsum perlite plaster—GA WP 1930

2-1/2� studs 16� o.c.—3/8� ROCKLATH Type X base, both sides, 8� o.c.—3.4 lb. N/A SA920 77self-furring diamond mesh lath, both sides, 8� o.c.—3/4� gypsum sand plaster, both sides—UL U484

Security Wall – 2-Hour RatingSTRUCTOCORE 18 ga. steel panels att to 18 ga. steel perimeter angles— N/A SA1119 783/4� min. coverage STRUCTO-BASE gypsum plaster sanded at 2:1 by weight in two coats—IMPERIAL Brand finish plaster applied 1/16� thick—UL Des U476

Non-Combustible Wall Systems – Cement BoardSteel Stud Partitions (Non-Load-Bearing) – 1-Hour Rating

1/2� DUROCK Brand cement panel and 1/4� ceramic tile—3-5/8� 20 ga steel 48 SA-840321 SA932 79studs 16� o.c.—3� SAFB—joint taped—alt. design 5/8� SHEETROCK Brand 50 Based on alt. design—SA-840313Gypsum Panels, FIRECODE Core, one side—UL Des U442

wt. 14

1/2� DUROCK Brand cement panel one side—3-5/8� 20 ga steel studs 47 Based on 5/8� SHEETROCK Brand Gypsum SA932 8016� o.c—3� SAFB—joints taped—5/8� SHEETROCK Brand Gypsum Panels, Panels, FIRECODE Core—USG-840222FIRECODE C Core other side—UL Des U457

wt. 7

Steel Stud Partitions (Non-Load-Bearing) – 2-Hour Rating1/2� DUROCK Brand cement panel—base layer 1/2� SHEETROCK N/A SA932 81Brand Gypsum Panels, FIRECODE C Core, one side, double-layer other side—3-5/8� 25 ga steel studs 16� o.c.—3� SAFB—cement panel att with 15⁄8� DUROCK Brand screws—joints taped—UL Des U474

1/2� DUROCK Brand cement panel and 1/4� ceramic tile—base layer 58 SA-851028 SA932 821/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3-5/8� 25 ga 56 Based on alt. design—SA-851016steel studs 16� o.c.—3� SAFB—joints taped—alt. design 2 layers 1/2�SHEETROCK Brand Gypsum Panels, FIRECODE C Core, one side—UL Des U443

wt. 18

Steel Stud Partitions (Non-Load-Bearing) – 1-Hour Rating1/2� DUROCK Brand cement panel—base layer 5/8� SHEETROCK Brand Gypsum N/A SA932 83Panels or sheathing, FIRECODE Core—min. 3-1/2� 20 ga studs 16� o.c.—3� SAFB—joints taped—UL Des U473

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—base layer 1/2� DUROCK N/A SA932 84Brand cement panel—min. 3-1/2� 20 ga studs 16� o.c.—3� SAFB—UL Des U485

1/2� DUROCK Brand cement panel—3-1/2� studs 16� o.c.—3� SAFB—joints taped N/A SA932 85and treated—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des U404

5/8� DUROCK Brand cement panel and 1/4� ceramic tile N/A SA932 86(USG veneer plaster system)—3-1/2� studs 16� o.c.—3�SAFB—UL Des 407

�������������������5" �������� �����������

�����������

����������������

45⁄8"

�����������

����������������

�����������

����������������

53⁄4"

�����������

����������������51⁄4"

����������������

��������������������������������������

61⁄8"��������������������������������������

������������������

�����������������������������

55⁄8"

��������

�����������43⁄4"

�������������������

�������������������

51⁄8"

������������

������������

4"

�����������������������������������43⁄4"

21⁄2"��������������

A

Page 14: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

14

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Non-Combustible Wall Systems – Cement Board (continued)Steel Stud Partitions (Load-Bearing) – 2-Hour Rating

1/2� DUROCK Brand cement panel—base layer 5/8� SHEETROCK Brand Gypsum N/A SA932 87Sheathing, FIRECODE Core—3-1/2� studs 16� o.c.—3� SAFB— joints tapedand treated—double-layer 1-5/8� SHEETROCK Brand Gypsum Panels, FIRECODECore, other side—UL Des 404

Chase Walls – 1-Hour Rating1/2� DUROCK Brand cement panel and 1/4� ceramic tile—1-5/8� 25 ga steel 61 Based on 3� SAFB & 35⁄8� studs— SA932 88studs 16� o.c. in two rows with horiz braces—1-1/2� SAFB—board att with SA-8405241-1/4� DUROCK Brand screws—joints taped—alt. design 5/8� SHEETROCK 60 Based on 3� SAFB & alt. design—SA-840515Brand Gypsum Panels, FIRECODE Core, one side—UL Des U445

Wt.17

1/2� DUROCK Brand cement panel one side—1-5/8� 25 ga steel studs 16� o.c. 57 Based on 3-5/8� 25 ga steel studs and 3� SAFB— SA932 89in two rows with horiz braces—1-1/2� SAFB in both stud cavities— SA-840505joints taped—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, other side—UL Des U458

wt. 7

Chase Wall – 2-Hour Rating1/2� DUROCK Brand cement panel and 1/4� ceramic tile—base layer 1/2� 65 SA-851112 SA932 90SHEETROCK Brand Gypsum Panels, FIRECODE C Core—1-5/8� 25 ga steel studs 62 Based on alt. design—SA-85110216� o.c. in two rows with horiz braces—1-1/2� SAFB—joints taped—alt. design 2 layers 1/22� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, one side—UL Des U444

wt. 18

Cavity Shaft Wall – 2-Hour Rating1/2� DUROCK Brand Cement Panel—5/8� SHEETROCK Brand Gypsum Panels, N/A SA926 91FIRECODE Core—1� SHEETROCK Brand Gypsum Liner Panels set betw USG steel SA93220 ga. min C-H studs 24� o.c.—1-1/2� SAFB—cement board screw att &laminated to gypsum panel—joints fin—UL Des U415 or U459

Wood Framed Wall Systems – Gypsum Drywall or Veneer PlasterWood Stud Partition (Load-Bearing) – 45-Minute Rating

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—2x4 16� o.c.— N/A SA924 92panels nailed 7� o.c.—1-5/8� cem ctd nails—joints fin—UL Des U317

wt. 6

Wood Stud Partitions (Load-Bearing) – 1-Hour Rating5/8� SHEETROCK Brand vinyl-faced Gypsum Panels, FIRECODE Core—2x4 16� o.c.— SA928 93panels fastened 7� o.c. with 1-7/8� fasteners—UL Des U305

wt. 7

1/2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, att direct & veneer finish N/A SA920 94only (not drywall)—2x4 16� o.c.—base nailed 7� o.c. 6d nails—1/16� veneer finish—joints fin—U of C 10-27-64

wt. 7

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or SHEETROCK Brand 34 Based on 16� stud spacing and screws SA924 95Gypsum Panels, water-resistant, FIRECODE Core—2x4 16� or 24� o.c.— 6� o.c.—USG-30-FT-G&Hpanels fastened 7� o.c. with 1-7/8� fasteners—joints fin—perim caulked— 37 Based on 24� stud spacing—UL Des U305 and UL Des U314— USG-860807

46 Based on 24� stud spacing & 3�SAFB—BBN-700725

wt. 7

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—2x4 16� o.c.— 45 RAL-TL-69-52 SA924 96base layer 1/4� SHEETROCK Brand GypsumPanels, appl vert with 4d ctd nails— 53 Based on 5/8� lamin. face layers & 1-1/2� SAFB—1/2� panel face layer strip lamin plus 6d nails 6� o.c. to top & bottom plates— USG-221-ST-G-Hjoints stag & fin—perimeter caulked—GA-WP-3341

wt. 8

Wd Stud—resil partition—5/8� SHEETROCK Brand Gypsum Panels, 41 Based on RC-1 chan or equiv one side only— SA924 97FIRECODE Core—2x4 16� o.c.—RC-1 or equiv chan one sides spaced USG-860802horiz 24� o.c.—panels att with 1� Type S screws—joints fin—perimetercaulked—T-1396-OSU

wt. 7

�������51⁄4"�������

���������������������

5"

�������������� �������

�������

43⁄4"�������

�������45⁄8"

�������

�������43⁄4"

�������

�������41⁄2"

�������

�����������������������������

��������

��������35⁄8"

��������������������

�������61⁄4"

����������������������������������

�������

����������������������

47⁄8"

�������������������������������

�������������������������������

51⁄2"

�����������

��������������������������������

57⁄8",

����������������

A

Page 15: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Wood Framed Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Wood Stud Partitions (Load-Bearing) – 1-Hour Rating

Resil partition 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C 50 BBN-760903 SA707 98Core—2x4 16� or 24� o.c.—3� SAFB—RC-1 chan or equiv SA924one side, spaced 24� o.c.—panels app horiz & att to channels—end joints back-blocked with RC-1 chan with 1� Type S screws—opp side direct att—joints fin—perimeter caulked—UL Des U327

wt 7

Wood Stud Partitions (Load-Bearing) – 2-Hour RatingDouble layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or N/A SA924 99SHEETROCK Brand Gypsum Panels, Water-Resistant, FIRECODE Core, or SHEETROCK SA928Brand Vinyl-Faced Gypsum Panels, FIRECODE Core, ea side—2x4 16� o.c.—base layer att 6� o.c.—face layer att 8� o.c.—joints fin—UL Des U301

wt. 12

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ea side— 59 RAL-TL-67-239 SA924 1002x4 16� o.c.—2� SAFB—RC-1 chan or equiv one side, spaced 24� o.c.— 49 Based on same construction without both base layers appl vert and face layers appl horiz—resil layers perim SAFB—RAL-TL-67-212caulked—joints fin—UL Des U334

wt. 12

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ea side— 58 USG-810219 SA924 1012x4 16� o.c.—2� SAFB—RC-1 chan or equiv one side, spaced 24� o.c.— 52 Based on same assembly (non-fire rated) both base layers appl vert and face layers appl horiz—resil layers perim without SAFB—USG-810218caulked—joints fin—UL Des U334

wt. 13

Double Stud Chase Wall (Load-Bearing) – 1-Hour RatingStag Wd Stud—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— N/A SA920 1022x4 spaced 24� o.c. max on ea side of 2x6 com plate—panels att 7� o.c.—perim SA924caulked—joints fin—UL Des U340

Double Stud Chase Wall (Load-Bearing) – 2-Hour RatingDouble layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, SA924 103outside, both sides—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, inside, both sides—2x4 wd studs 24� o.c.—UL Des U342

Alternate based on 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 57 3-1/2� glass fiber both walls—RAL-TL-73-224 N/A 104both outside double layer & inside single layer—GA WP 3810

Alternate based on 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, 57 3-1/2� glass fiber both walls— N/A 105outside double layers only—GA WP 3812 based on TL-73-224

Double Stud Chase Walls (Non-Load-Bearing) – 1-Hour RatingStag Wd Stud—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE 54 Based on screws or nails 7� o.c.— SA924 106Core—2x3 non-load-bearing studs 16� o.c.—2x3 plates 1� RAL-TL-77-149apart—panels fastened 7� o.c.—3� SAFB one side—jointsfin—perim caulked—est. fire rating based on UL Des U305 and U340

wt. 8

Stag Wd Stud—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core— 45 Based on FIRECODE Core panels— SA924 1072x4 16� o.c. on 2x6 com plate—panels att 7� .c.—2� SAFB one side— RAL-TL-69-213operim caulked—jointsfin—est. fire rating based on UL Des U305

wt. 8

Wd Stud—base layer 1/4� SHEETROCK Brand Gypsum Panels—face layer 55 Based on 1-1/2� THERMAFIBER SAFB N/A 1081/2� SHEETROCK Brand Gypsum Panels, FIRECODE Core, laminated in cavity—G & H BW-32STto base layer—2x4 wd studs 16� o.c.—GA WP 5510

10"

�������������� �������

�������������� �������

��������������

63⁄4"

��������������

�������

71⁄4"

�������

121⁄4"�������

��������������

�������

��������������

�������

63⁄8"

�������

����������������

����������������

6"

����������������

����������������

6"

��������������

��������������6"

�������51⁄4"�������

A

SA100/USG Corporation 15

Page 16: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

16

Partitions

Fire-rated construction Acoustical performance FolderDetail & physical data Description & test no. STC Description & test no. reference

Wood Framed Wall Systems – Gypsum Drywall or Veneer Plaster (continued)Double Stud Chase Walls (Non-Load-Bearing) – 2-Hour Rating

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—2 rows 51 RAL-TL-69-214 SA924 1092x4 16� o.c. on sep plates 1� apart—base layer att 24� o.c.—face layer 56 Based on 3-1/2� thick insulation in one att 8� o.c.—stagger vert joints 16� o.c.—perim caulked—joints fin— cavity—USG-710120GA-WP-3820 58 GA-NGC-3056

wt. 13

Stag Wd Stud—Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C 47 RAL-TL-69-211 SA924 110Core—2x4 16� o.c. on 2x6 com plate—base layer att 24� o.c.—face layer att 51 GA-NGC-23778� o.c.—stagger vert joints 16� o.c.—perim caulked—joints fin—GA-WP-3910

wt. 13

Wood Framed Wall Systems – Conventional Lath & PlasterWood Stud Partition (Load-Bearing) – 1-Hour Rating

3/8� ROCKLATH base, both sides, 4� o.c.—2x4 16� o.c.—1/2� 1:2 gypsum-sand N/A 111plaster—GA WP 3430

Wood Framed Wall Systems – Cement BoardWood Stud Wall (Load-Bearing) – 1-Hour Rating

1/2� DUROCK Brand cement panel and 1/4� ceramic tile—2x4 studs 37 USG-840404 SA932 11216� o.c.—3-1/2� SAFB—board att 8� o.c.—joints taped—alt. design 40 Based on alt. design—USG-8403145/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, one side—UL Des U329

wt. 15

1/2� DUROCK Brand cement panel—base layer 15/32� plywood—2 x 4 studs N/A SA932 11316� o.c.—3� SAFB—joints taped and treated—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des U303

Wood Stud Wall (Load-Bearing) – 2-hour Rating1/2� DUROCK Brand cement panel—base layer 5/8� SHEETROCK Brand Gypsum N/A SA932 114Sheathing, FIRECODE Core—2 x 4 studs 16� o.c.—3� SAFB—joints taped and treated—double-layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des U308

Double Stud Chase Wall (Load-Bearing) – 2-Hour Rating1/2� DUROCK Brand cement panel and 1/4� ceramic tile—2 rows 2x4 16� o.c. 50 SA-840523 SA932 115on 2x8 com plate—3-1/2� SAFB both cavities—board att 8� o.c.—joints taped—load-bearing up to 50% allowable design load—WHI-495-0505 & 0508

wt. 18

�������������������

9"

�������������������

�����������

��������������������������������

57⁄8",6"

����������������

�����������

����������������

51⁄8",51⁄4"

�������������������5" �������� �����������

���������������������

���������������������53⁄8"

��������������8"

��������������

��������������

101⁄2"

��������������

A

Page 17: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 17

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Non-Combustible Ceiling Systems – Gypsum Drywall or Veneer PlasterSteel Bar Joist Framing – 1-Hour Rating

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—panels screw att N/A N/A 112� o.c. rt. angl. to 3-5/8� 25 ga steel studs 24� o.c.—studs wire tied to open web steel joists 24� o.c.—joints fin—2-1/2� concrete on riblath over joist—GA FC 1105—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODEor FIRECODE C Core, and veneer finish surface

clg. wt. 2

Steel Bar Joist Framing – 1-1/2-Hour RatingUSG Drywall Suspension System—5/8� SHEETROCK Brand Gypsum Panels, N/A SA923 2FIRECODE C Core—susp grid with main run 4� o.c. and cross tees 2� o.c— SA920gypsum panels screw-att to grid—joints stag and fin—min 1� roof insul and 5/8� gypsum bd on steel deck over bar joists—1 hr. rating based on assembly with 1/2� thick panels—UL Des P510—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 4

USG Drywall Suspension System—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, N/A SC2000 3FIRECODE C Core—gypsum panels screw-att below grid with 1� Type S screws SC196312� o.c.—joints stag & fin—2-1/2� conc on riblath over bar joist—UL Des G528—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

1/2� x 2� x 4� Gypsum Lay-In Panels, FIRECODE C Core, in Susp Exp Grid N/A SC2000 4Sys—2-1/2� conc on riblath over bar joist—UL Des G259 —rating also applies SC1963with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—panels screw att N/A N/A 512� o.c. rt. angl. to met fur chan 24� o.c.—chan wire tied to open web steel joists 24� o.c.—joints fin—2� concrete on riblath or steel deck over joist—UL Des G502—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODEor FIRECODE C Core, and veneer finish surface

clg. wt. 2

Steel Bar Joist Framing – 2-Hour Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—met fur chan 24� o.c.— 54* ASTM E1414 SA923 6joints fin—2-1/2� conc on riblath or corrug stl deck over bar joist—UL Des G515— SA920rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core,and veneer finish surface

clg. wt. 3

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—panels screw N/A 7att 8� o.c. rt. angl. to met fur chan 48� o.c.—chan wire to open websteel joists 12� o.c.—UL Des G503—rating also applies with IMPERIAL BrandGypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 2

*CAC value per ASTM E1414 test procedure for horizontally adjacent spaces.

�����

�����

16"

����������

137⁄8"

�����15 3⁄8"

�����

��������

��������

����

22"

������

����185⁄8"

������

������������

271⁄4"

�����18 5⁄8"

�����

B

Page 18: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Non-Combustible Ceiling Systems – Gypsum Drywall or Veneer Plaster (continued)

Steel Bar Joist Framing – 2-Hour Rating (continued)1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—panels screw att 53 NGC-4075 N/A 812� o.c. rt. angl. to met fur chan 24� o.c.—chan wire tied to open web steel joists 24� o.c.—joints fin—2-1/2� concrete on riblath or steel deck over joist—GA FC 2030—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODEor FIRECODE C Core, and veneer finish surface

USG Drywall Suspension System—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, N/A SC2000 9FIRECODE C Core—gypsum panels screw-att below grid with 1� Type S screws SC196312� o.c.—joints fin—2-1/2� conc on riblath or steel deck over bar joist—3 hr. rating with 5/8� panels & 3� thick concrete—UL Des G523—rating also applies with IMPERIAL Brand gypsum base, FIRECODE or FIRECODE C Core, andveneer finish surface

USG Drywall Suspension System—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, N/A SC2000 10FIRECODE C Core—gypsum panels screw-att below grid 8� o.c.—joints stag & fin— SC19632-1/2� conc on riblath over bar joist—UL Des G526—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

1/2� x 24� x 24� Gypsum Lay-In Panels, FIRECODE C Core, on Susp Exp Grid Syst— N/A SC2000 112-1/2� conc deck on riblath or corrugated steel deck over bar joist— SC1963UL Des G222—fire rating 11⁄2 hr. with 1/2� x 24� x 48� panels; —UL Des G259—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core,and veneer finish surface

clg. wt. 2

Steel Bar Joist Framing – 3-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—met fur chan 24� o.c.— N/A SA923 12panels att 12� o.c.—joints fin—2-1/2� conc on corrugated steel deck or riblath over bar joist——UL Des G512

clg. wt. 3, clg. wt. 4

USG Drywall Suspension System—5/8� SHEETROCK Brand Gypsum Panels, N/A SA923 13FIRECODE C Core—susp grid to main run 4� o.c. and cross tees 2� o.c.—gypsum panels screw-att to grid—joints fin—3-1/4� conc on riblath or corrugated steel deck over bar joist—rating also applies with 5/8� panels and 2-3/4� conc slab—UL Des G529—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 3

Steel C-Joist Framing – 1-Hour Rating1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—7� 18 ga steel 39 Based on 9-1/2� 16 ga steel joists— SA923 14joists 24� o.c.—double layer gypsum panel clg att to joists —double layer USG-760105gypsum panels around beam—joints stg—UL Des L524—rating also applies 43 Based on 9-1/2� 16 ga steel joists and 3�with IMPERIAL Brand FIRECODE or FIRECODE C base and veneer finish surface SAFB—USG-760310

56 Based on 9-1/2� 16 ga steel joists and carpet pad—USG-760106

60 Based on 9-1/2� 16 ga steel joists and carpet & pad with 3� SAFB—USG-760405clg. wt. 3

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—7-1/2� 18 ga struc 45 Based on RC-1 resil chan or equiv SA923 15steel joists 24� o.c.—2-1/2� conc flr on corrug steel deck—gypsum panel ceiling 24� o.c.—KAL-443536att to joists with 1� Type S-12 screws 12� o.c.—joints fin—est. fire rating 70 Based on carpet & pad—KAL-443535based on witnessed laboratory test—rating also applies with IMPERIAL BrandGypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 3

Resil ceiling—1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— N/A N/A 16panels screw att 12� o.c. rt. angl. to RC-1 chan or equiv 24� o.c.—RC-1 chan or equiv screw att to 6� 18 ga struc steel joists 24� o.c.—joints fin—2�concrete on steel deck over joist—GA FC 1145—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 2

����10 1⁄2"

�����

�������

105⁄8"����

����������

��������������

95⁄8"

����211⁄4"

�����

���������

16"

��������

��������

����

22"

������

����21"24"

�����157⁄8"

�����

18

B

Page 19: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 19

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Floor/Ceiling Assemblies – 1-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw-attached to SA923 17RC-1 channels (or equivalent)—joints finished—channels screw-attached to bottom chord of steel trusses—insulation optional in concealed space directly over gypsum ceiling membrane—concrete floor over riblath or corrugated steel deck—UL Des G540, G542, G543, G544

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw-attached to SA923 18RC-1 channels (or equivalent)—joints finished—channels screw-attached to bottom chord of steel trusses—insulation optional in concealed space directly over gypsum ceiling membrane—plywood flooring or floor toppingmixture over plywood subflooring—UL Des L549, L551, L552, L553

Roof/Ceiling Assemblies – 1-Hour RatingDouble layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, screw- SA923 19attached to met fur chan or RC-1 channels (or equivalent)—joints finished—channels spaced max 24� o.c., mechanically attached to bottom chord of steel trusses—insulation optional in concealed space, spaced a min 1� from gypsum ceiling membrane—roof covering and roof insulation over steel roof deck—UL Des P515

Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw- SA923 20attached to met fur chan or RC-1 channels (or equivalent)—joints finished— channelsspaced max 24� o.c., mechanically attached to bottom chord of steel trusses—insulation optional in concealed space directly over gypsum ceiling membrane—roof covering and roof insulation over steel roof deck—UL Des P515, P524

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw-attached to RC-1 SA923 21channels (or equivalent)—joints finished—channels 16� o.c., screw-attached to bottom chord of steel trusses—steel roof deck over trusses—roof covering and roof insulation over 1/2� DUROCK Brand Cement Board or 1/2�SHEETROCK Brand Gypsum Panels, min 1� thick insulation for 1 hr rating, min 2� thick insulation for 1-1/2 hr rating—UL Des P521, P525, P527, P529

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, screw-attached to RC-1 SA923 22channels (or equivalent)—joints finished—channels screw-attached to bottom chord of steel trusses—insulation optional in concealed space directly over gypsum ceiling membrane—roofing system over min. 23/32� thick plywood decking—UL Des P523, P526, P528, P530

B

Page 20: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

20

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Non-Combustible Ceiling Systems – Gypsum Drywall or Veneer Plaster (continued)Steel C-Joist Framing – 1-1/2-Hour Rating

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—3/4� T & G 48 USG-771101 SA923 23plywd flr att to joists—9-3/8� 16 ga struc steel joists 24� o.c.—double layer 51 Based on carpet & pad—SA-781110gypsum panel clg att to RC-1 chan or equiv screw att to joist 16� o.c.—joints fin—UL Des L527—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, veneer surface finish

clg. wt. 5

Steel C-Joist Framing – 2-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—7-1/2� 18 ga struc 44 KAL-443533 SA923 24steel joists 24� o.c.—2-1/2� conc flr over corrug steel deck—dbl layer gypsum 73 Based on carpet & pad—panel ceiling—base panels att with 1� Type S-12 screws 12� o.c.—face KAL-443680panels att with 1-7/8� Type S-12 screws 12� o.c.—joints stag and fin—est 47 Based on RC-1 resil chan or equivfire rating based on witnessed laboratory test—rating also applies with 24� o.c.—KAL-443534IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 5

Precast Concrete – 2-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—met fur N/A SA923 25chan 24� o.c.—panels att with 1� Type S screws—joints fin—2�prestressed reg or lightwt conc units with 6� deep stems 48� o.c.—UL Des J502 or J503—rating also applies with IMPERIAL BrandGypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 3

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core—panels screw att N/A N/A 268� o.c. rt. angl. to met fur chan 24� o.c.—joints fin—chan screw att to hanger straps on 2-1/2� precast conc joists 35� o.c.—joist leg 10� deep—GA FC 2120—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODEC Core, and veneer finish surface

clg. wt. 3

Precast Concrete – 3-Hour Rating5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—met fur N/A SA920 27chan 24� o.c.—panels att with 1� Type S screws—joints fin—prestressed 2-3/4� reg or 2-1/2� lightwt conc units with 6� deep stems 48�o.c.—UL Des J502 or J504

clg. wt. 3

Non-Combustible Ceiling Systems – Conventional Lath & PlasterSteel Bar Joist Framing – 1-Hour Rating

5/8� RED TOP gypsum plaster, sanded 1:2-1:3—applied over 3/8� riblath wire N/A N/A 28tied 5� o.c. to open web steel joists 24� o.c.—2� concrete on riblath over joist—GA FC 1180

Alternate based on 5/8� RED TOP gypsum plaster-vermiculite or 7/8� RED TOP N/A N/A 29wood fiber plaster—GA FC 2160

clg. wt. 4

Steel Bar Joist Framing – 2-Hour Rating3/4� cold rolled channel furred or suspended—3.4# diamond mesh lath N/A SA920 30& 5/8� 100:2-100:3 gypsum-sand plaster—2-1/2� concrete on riblath or 28 ga. corrugated steel deck over bar joist—BMS-92����

������

141⁄4"

�����145⁄8"

����������

�����������10 1⁄4"

�������

��������������������

14"

����������

�����������9 1⁄2"

�������

��������������

111⁄4"����

����������

��������������

117⁄8"

B

Page 21: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 21

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Non-Combustible Ceiling Systems – Conventional Lath & Plaster (continued)Steel Bar Joist Framing – 21⁄2-Hour Rating

3/4� cold rolled channel furred or suspended—3.4# diamond mesh lath N/A SA920 31& 3/4� 100:1-100:1 gypsum wood fiber-sand plaster—2-1/2� concrete on riblath or 28 ga. corrugated steel deck over bar joist—UL Report R5429-1

Steel Bar Joist Framing – 3-Hour Rating3/4� cold rolled channel furred or suspended—3.4# diamond mesh lath N/A SA920 32& 7/8� neat wood fiber gypsum plaster—2-1/22� concrete on riblath or 28 ga corrugated steel deck over bar joist—BMS-92

Alternate based on 5/8� 1:2-1:3 RED TOP gypsum plaster-vermiculite N/A N/A 33or 7/8� RED TOP wood fiber plaster neat—GA FC 3140

clg. wt. 4

Steel Bar Joist Framing – 4-Hour Rating7/8� 1:2-1:3 RED TOP gypsum plaster-vermiculite—applied over 3/8� riblath N/A N/A 34wire tied 5� o.c. to open web steel joists 24� o.c.—21⁄2� concrete on riblath over joist—BMS 92

clg. wt. 5

Rib-Type Steel Roof Deck – 1-1/2-Hour RatingSuspended 3.4# diamond mesh metal lath & 3/4� 100:2-100:3 N/A SA920 35gypsum-sand plaster—rib type steel roof deck with 1� wood-fiber insulation—NBS-57

Suspended 3.4# diamond mesh metal lath & 1� 100:2 gypsum-sand N/A SA920 36plaster— rib type steel roof deck with 1-1/2� wood-fiber insulation—NBS-58

Wood Framed Ceiling Systems – Gypsum Drywall or Veneer PlasterFloor/Ceiling – 1-Hour Rating

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, ceiling—1� nom 38 32 Based on 1-1/4� nom wd flr—CK-6412-7 SA924 37wd sub & fin flr—2x10 wd joist 16� o.c.—panels att 6� o.c.—joints fin— 39 56 Based on 1-1/4� nom wd flr, 44 oz carpet & UL Des L501—rating also applies with IMPERIAL Brand gypsum base, FIRECODE 40 oz pad atop flooring—CK-6412-8or FIRECODE C Core, and veneer finish surface

1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling—1� N/A SA924 38nom wd sub & fin flr—2x10 wd joist 16� o.c.—panels att 6� o.c.—joints fin—UL Des L512

clg. wt. 3

Resil ceiling—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core N/A SA924 39—1� nom wd sub & fin flr—2x10 wd joist 16� o.c.—RC-1 chan or equiv spaced 24� o.c.—joints fin—UL Des L514—rating also applies with IMPERIALBrand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

Resil ceiling—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core 47 67 Based on 1/2� SHEETROCK Brand gypsum SA924 40—1-1/4� nom wd sub & fin flr—44 oz carpet & 40 oz pad atop flr—2x10 wd panels, FIRECODE C Core—CK-6512-7joist 16� o.c.—RC-1 chan or equiv screw att to joists—joints fin—est. fire 48 66 Based on 5/8� SHEETROCK Brand gypsum rating based on UL Des L514 panels, FIRECODE Core—CK-6412-9

clg. wt. 3

��������������������

�������

��������������������

�������

����������

195⁄8"203⁄8"

�����15 3⁄8"

����������

��������

������14"

����������

141⁄8"

B

Page 22: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

22

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Wood Framed Ceiling Systems – Gypsum Drywall or Veneer Plaster (continued)Floor/Ceiling – 1-Hour Rating

Resil ceiling—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— 51 46 Based on 1/2� SHEETROCK Brand Gypsum SA924 411-1/4� nom wd sub & fin flr—2x10 wd joist 16� o.c.—3� SAFB betw joists— Panels, FIRECODE C Core—CK-6512-9RC-1 chan or equiv screw att to joists—panels att with 1� Type S screws— 50 46 Based on 5/8� SHEETROCK Brand Gypsum joints fin—est fire rating based on UL Des L514—rating alsoapplies with Panels, FIRECODE Core—CK-6412-3IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneerfinish surface

Resil ceiling—1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core 52 71 Based on 1/2� SHEETROCK Brand Gypsum SA924 42—1-1/4� nom wd sub & fin flr—44 oz carpet & 40 oz pad atop flr—2x10 Panels, FIRECODE C Core—CK-6512-8wd joist 16� o.c.—3� SAFB betw joists—RC-1 chan or equiv screw att to 51 70 Based on 5/8� SHEETROCK Brand Gypsum joists—panels att with 1� Type S screws—joints fin—est. fire rating based on Panels, FIRECODE Core—CK-6412-4

clg. wt. 3 UL Des L514

Resil ceiling—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— 59 Based on 3� SAFB, 3/4� gypsum concrete & SA924 431-5/8� perlite-sand conc over 5/8� plywd subflr—2x10 wd joists 16� o.c.— 1/2� SHEETROCK Brand Gypsum Panels, RC-1 chan or equiv screw att to joists—joints fin—UL Des L516—rating also FIRECODE C Core—USG 740704applies with IMPERIAL Brand gypsum base, FIRECODE or FIRECODE C Core, and 47 Based on 3� SAFB, vinyl tile atop flooring—veneer finish surface USG 740703

65 Based on 3� SAFB, 44 oz. carpet & 40 oz.pad atop flooring—USG 740705

clg. wt. 3

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling—wd truss SA924 44of 2 x 4 lumber secured with steel truss plates—trusses 24� o.c.—3/4� nom plywood flr—RC-1 channels (or equivalent) spaced 12� or 16� o.c.—joints finished—optional insulation directly over gypsum ceiling membrane—optional ceiling damper—UL Des L521, L546, L550

clg. wt. 3

Base layer: 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core— N/A SA920 45screw att at rt. angl. to 2x10 wd joists 24� o.c.—Face layer: 5/8� SHEETROCKBrand Gypsum Panels, FIRECODE Core screw att 12� o.c. at rt angl. to joists—joints of second layer offset 24� and fin.—Floor: 1/2� plywd w/ ext glue appl rt. angl to joists w/8d nails. Also for roof-ceilings, incl. trusses—GA FC 5406and RC2601—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 5

Base layer: 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— N/A SA920 46screw att at rt. angl. trusses 24� o.c.—Face layer: 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core screw att 12� o.c. at rt angl. to joists—joints of second layer offset 24� and fin.—Floor: 23/32� plywood w/ ext glue appl rt. angl to joists w/ 6d ring nails—UL Des L542—rating also applieswith 1/2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling— N/A SA920 47wd truss of 2x4 lbr secured with steel truss plates—trusses 24� o.c. SA924—3/4� nom plywd flr—met fur chan 24� o.c. wire-tied to trusses—panels att with 1� Type S screws 12� o.c.—joints fin—UL Des L528*—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODEC Core, and veneer finish surface

clg. wt. 3

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling—wd N/A SA920 48truss of 2x4 lbr secured with steel truss plates—trusses 24� o.c.— SA9243/4� nom plywd flr—susp grid with main run 4� o.c. and crosstees 2� o.c.—panels att with 1� Type S-12 screws 12� o.c.—joints fin—UL Des L529—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODEor FIRECODE C Core, and veneer finish surface

clg. wt. 3

1/2� or 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling— N/A SA924 491� nom wd sub & fin flr—2x10 wd joist 16� o.c.—susp grid with mainrun 4� o.c. and cross tees 2� o.c.—panels screw-att below grid—joints fin—UL Des L525—rating also applies with IMPERIAL Brand GypsumBase, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 3

* RC-1 Resilient Channel or equivalent may be used in place of metal furring channel.

����������

����������

������

����

������������

207⁄8"

��������

������

141⁄4"

����������

��������������

133⁄4"

�������

����������

11"

����������

205⁄8"

��������������

125⁄8"

�������

����������

����������

�������

B

Page 23: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 23

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Wood Framed Ceiling Systems – Gypsum Drywall or Veneer Plaster (continued)Floor/Ceiling – 1-Hour Rating

1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, ceiling—3/4� 47 40 RAL-TL-81-87—RAL-IN-81-16 SA920 50T&G plywd—I-shaped wd joist 24� o.c.—met fur chan 24� o.c. 54 Based on carpet & pad atop SA924clip-att to joist—1� THERMAFIBER insul laid over chan below joists— flooring—RAL-IN-81-17panels screw att to chan 12� o.c.—joints fin—UL Des L530 based on 43 Based on cushioned vinyl atop TJI� joists—UL Des L531—9� deep WSI� joist; rating also applies flooring—RAL-IN-81-19with 1⁄2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

clg. wt. 3

Floor/Ceiling – 1-1/2-Hour RatingResil ceiling—2 layers 1/2� SHEETROCK Brand Gypsum Panels, N/A Assembly not recommended when SA924 51FIRECODE C Core—1� nom wd sub & fin flr—2x10 wd joist 16� o.c.— sound control is a major considerationRC-1 chan or equiv spaced 24� o.c. screw att over base layer panels—face layer screw att to chan 12� o.c.—joints fin—UL Des L510—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 4

Resil 2 layers 1/2� IMPERIAL Brand Gypsum Base, FIRECODE C Core, & N/A SA920 52veneer finish ceiling—1� nom wd sub & fin flr—2x10 wd joist 16� o.c.—RC-1 chan or equiv 24� o.c. screw-att over base layer—face layer screw att to chan 12� o.c.—1/16� veneer finish—joints taped—UL Des L510

clg. wt. 4

Floor/Ceiling – 2-Hour RatingResil ceiling—2 layers 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE N/A Assembly not recommended when SA924 53C Core—1� nom wd sub & fin flr—2x10 wd joist 16� o.c.—RC-1 chan or sound control is a major consideration SA920equiv spaced 24� o.c. screw att over base layer panels—face layer screw att to chan 12� o.c.—joints fin—UL Des L511—rating also applies withIMPERIAL Brand Gypsum Base, FIRECODE or FIRECODE C Core, and veneer finish surface

clg. wt. 5

Floor/ceiling—floor of 8� x 8� ceramic tile, 1/2� DUROCK Brand exterior cement 60 RAL-TL-89-141 (54 MTC)— SA707 54board, 1� SHEETROCK Brand Gypsum Liner Panels, 1/22� plywood—2x10 52 RAL-IN-89-5 SA924wd joist 16� o.c.—3� SAFB —ceiling of 2 layers 5/8� SHEETROCK Brand 58 Based on vinyl tile over oriented board Gypsum Panels, FIRECODE C Core, over RC-1 chan or equiv 16� o.c.— in place of ceramic tile and cement UL Des L541—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or board—RAL-TL-89-145 (53 MTC)—FIRECODE C Core, and veneer finish surface 51 RAL-IN-89-7

59 Based on carpet/pad over orientedstrand board in place of ceramic tile andCement Board—RAL-TL-89-146 (54 MTC)

62 —RAL-IN-89-8

Floor/ceiling—floor of carpet/pad, 1-1/2� flooring, 1/2� plywood—2x10 wd 59 RAL-TL-90-40 (54 MTC)— SA924 55joists 16� o.c.—3� SAFB—ceiling of 2 layers 5/8� SHEETROCK Brand Gypsum 69 RAL-IN-90-5Panels, FIRECODE C Core, over RC-1 chan or equiv 16� o.c.—UL Des L541— 59 Based on vinyl tile in place of rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE or carpet/pad—RAL-TL-90-40FIRECODE C Core, and veneer finish surface 37 (54 MTC)—RAL-IN-90-6

Base layer: 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core— N/A SA920 56screw att at rt. angl. to 9-1/2� min wood truss joists 24� o.c. RC-1 chan or equiv or metal fur chan at rt. angl. to joists 16� o.c.—Double face layer: 5/8�SHEETROCK Brand Gypsum Panels, FIRECODE C Core screw att 8� o.c. at rt angl. to chan—joints offset 24� and fin.—Floor: 5/8� T&G plywood w/ext glue appl rt. angl to joists—UL Des L538—rating also applies with5/8� IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

Roof/Ceiling Assemblies– 1-Hour Rating5/8� SHEETROCK Brand Gypsum Panel, FIRECODE C Core, pitched wood trusses N/A SA924 57of min. 2 x 4 lumber, any UL Class A, B or C roofing system—RC-1 channels or equivalent spaced 12� or 16� o.c.—joints finished—optional insulation directly over gypsum ceiling membrane—ceiling damper optional—UL Des P522

����������

��������������

121⁄2"

��������������

�����������

����

���

���

���

���

���

��

�������

���������������������

13"

�����������������������������������������������

���������������������

131⁄4"

����������

����������

���������������������

133⁄4"

��������������������

���������������������

131⁄2"

��������������������

���������������������

131⁄2"

����������

125⁄8"

�������

B

Page 24: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 2324

Ceilings

Fire-rated construction Acoustical performance FolderDetail & Physical data Description & test no. STC IIC Description & test no. reference

Wood Framed Ceiling Systems – Conventional Lath & PlasterFloor Ceiling – 1-Hour Rating

5/8� 1:2 RED TOP gypsum plaster-perlite over 3/8� type X ROCKLATH plaster N/A N/A 58base at rt. angl. to 2x10 wd joists 16� o.c.—1� nom. T&G sub and finish floor—GA FC 5470

1/2� 1:2 sanded RED TOP gypsum plaster over 3/8� type X ROCKLATH plaster N/A N/A 59base at rt. angl. to 2�x10� joists 16� o.c.—1� nom. T&G sub and finish floor—GA FC 5490

5/8� 1:2-1:3 sanded RED TOP gypsum plaster over 3.4# diamond lath nailed N/A N/A 606� o.c. at rt. angl. to 2x10 wd joists 16� o.c.—1� nom. T&G sub and finish floor—GA FC 5510

clg. wt. 4

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

Acoustical and Air Distributing Ceilings

3-Hour Rated Acoustical Floor-Ceiling Assemblies5/8� or 3/4� FR-83 acoust clg panels in DXLP (with Types PSS, PSSP, PSR & SC2000 61PSRP metal ceiling pans), DXL, DXLZ or SDXL Susp Exp Grid Syst — SC1963light fixt and air duct optional— 3-1/4� concrete on 1-1/2� stl roof deck—UL Des D218

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp DXLA, DXLZA or SDXLA Susp Exp Grid Syst may be SC2000 62Exp Grid Syst—light fixt and air duct optional—3-1/4� concrete on cellular and used instead, but fire rating is limited to 2-hr.; SC19633-1/2� concrete on fluted stl floor units—UL Des D219 DXLT or DXLTZ Susp Exp Grid Syst may be also used,

but fire rating is limited to 1-1/2-hr.

5/8� or 3/4� FR-83 or FR-X1 or 1/2� or 5/8� FR-4 or 1/2� FC-CB-acoust clg DXLA, DXLZA or SDXLA Susp Exp Grid Syst may be used SC2000 63panels in DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt and air instead, but fire rating is limited to 2-hr.; DXLT, DXLTA, SC1963duct optional—3-1/2� concrete deck on riblath over bar joists— DXLTZ or DXLTZA Susp Exp Grid Syst may be also used, UL Des G205 but fire rating is limited to 1-1/2-hr.; 1/2� FC-CB gypsum

panels may be used as a clg panel for fire ratings of 1 or 1-1/2-hr.

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXL, DXLZ or SDXL DXLA, DXLZA, SDXLA or ZXLA Susp Exp Grid Syst may SC2000 64Susp Exp Grid Syst—light fixt and air duct optional—3� concrete deck used instead, but fire rating is limited to 2-hr.; 1/2� SC1963on riblath over bar joists—UL Des G211 FC-CB gypsum panels may be used as a clg panel for

fire rating of 1-hr.

5/8� FR-81; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in DXL, DXLZ When FR-4 or M clg panels are used, the fire rating is SC2000 65or SDXL Susp Exp Grid Syst —light fixt and air duct optional—3-1/2� concrete limited to 2-hr.; 1/2� FC-CB gypsum panels may be SC1963deck on riblath or steel deck (increase conc. 1/2�) over bar joists— used as a clg panel for fire ratings of 1- or 1-1/2-hr. UL Des G213

2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies3/4� FR-83 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— SC2000 66light fixt and air duct optional—2-1/2� conc deck deck on fluted or cellular steel SC1963floor—UL Des D215

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

243⁄8"����������

221⁄2"����������

23"213⁄8"����������

249⁄16"min.

203⁄4"

223⁄4"

��������������������

����������

11 1⁄4"

B

Page 25: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 25

Ceilings

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies (continued)5/8� or 3/4� 12� x 12� or 24� FR-83 acoust clg panels in Concealed Z-Spline SC2000 67Grid Syst—light fixt and air duct optional—2-1/2� concrete deck on riblath SC1963over bar joists—UL Des G002

3/4� 12� x 12� or 24�, or 24� x 24� FR-83 acoust clg panels in Concealed SC2000 68Z-Spline Grid Syst—light fixt and air duct optional—2-1/2� concrete deck SC1963on riblath over bar joists—UL Des G007

5/8� or 3/4� 12� x 12�, or 24� x 24� FR-83 acoust clg panels in DXL, DXLZ or SDXL SC2000 69Concealed Grid Syst—light fixt and air duct optional— 2-1/2� concrete deck on SC1963riblathover bar joists—UL Des G008

3/4� 12� x 12�, or 24� x 24� FR-83 acoust clg panels in DXL, DXLA, DXLZA, SC2000 70ZXLA, DXLZ, SDXL or SDXLA Concealed Z-Spline Grid Syst—light fixt and air duct SC1963optional—2-1/2� concrete deck on riblath over bar joists—UL Des G040

5/8� FR-81 or FR-4; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in SC2000 71DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt and air duct optional— SC19632-1/2� concrete deck on riblath over bar joists—UL Des G202

5/8� or 3/4� FR-83 acoust clg panels in DXL Susp Exp Grid Syst— light fixt DXLT Susp Exp Grid Syst may be used instead, but fire SC2000 72and air duct optional—2-1/2� concrete deck on riblath over bar joists— rating is limited to 1-1/2-hr. SC1963UL Des G203

5/8� FR-81, FR-4 or M; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels SC2000 73in DXL, DXLA, DXLZ, DXLZA, SDXL or SDXLA Susp Exp Grid Syst— light fixt SC1963and air duct optional—2-1/2� concrete deck on riblath over bar joists—UL Des G204

5/8� FR-81 or FR-4; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in SC2000 74DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt and air duct optional— SC19632-1/2� concrete deck on riblath over bar joists—UL Des G215

5/8� or 3/4� FR-83 acoust clg panels in DXL, SDXL or DXLZ or Susp Exp Grid SC2000 75Syst—light fixt and air duct optional— 2-1/2� concrete deck on riblath over SC1963bar joists—UL Des G227

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

213⁄8"

26"231⁄4"23"����������

221⁄2"

273⁄8"

211⁄2"

26"

�����

243⁄8"

213⁄8"

B

Page 26: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Ceilings

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies (continued)3/4� AP min. acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst-— SC2000 76light fixt and air duct optional—2-1/2� concrete deck on riblath over bar SC1963joists—UL Des G228

5/8� or 3/4� FR-83 or 3/4� FR-X1-acoust clg panels in DXL, DXLA, DXLZ, SC2000 77DXLZA, SDXL or SDXLA Susp Exp Grid Syst—light fixt and air duct optional— SC19631/2� floor topping over 2� T&G building units on bar joists—UL Des G230

3/4� FR-83 acoust clg panels in DXL, DXLA, DXLZ, DXLZA, SDXL or SDXLA SC2000 78Susp Exp Grid Syst—light fixt and air duct optional—2-1/2� concrete deck on SC1963riblath over bar joists—UL Des G231

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust cig panels in Susp Exp Grid Syst— SC2000 79light fixt optional—2-1/2� concrete deck on riblath over bar joists—UL Des G234 SC1963

3/4� FR-83 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst—light SC2000 80fixt and air duct optional—2-1/2� concrete deck on riblath over bar joists— SC1963UL Des G252

3/4� FR-83 or FR-X1 acoust clg panels in DXLT, DXLTA, DXLTZ or DXLTZA Susp SC2000 81Exp Grid Syst—light fixt and air duct optional—2-1/2� concrete deck on riblath SC1963over bar joists—UL Des G265

5/8� FR-81, FR-4 or M; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in DXLTA or DXLTZA Susp Exp Grid Syst may be used SC2000 82DXL, DXLA, DXLT, DXLTZ, DXLZ, DXLZA, SDXL or SDXLA Susp Exp Grid Syst— instead, but fire rating is limited to 1-1/2-hr. SC1963light fixt and air duct optional—2-1/2� conc deck with 6� deep pan beam—UL Des J201

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXL, DXLT, DXLTZ, DXLZ SC2000 83or SDXL Susp Exp Grid Syst—light fixt and air duct optional—2� prestressed conc SC1963units with 6� deep stems 48� o.c.—UL Des J202

5/8� FR-4; or 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in DXL, DXLA, SC2000 84DXLZ, DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt and air duct SC1963optional—USG Drywall Suspension System (DGL)-1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—susp grid with main runners and cross tees—gypsum panels screw-att to grid-joints stag & fin—1� nom wd sub (diagonally) or 15/32�wd sub (perpendicular) over wd joists 16� o.c.; 1� nom or 19/32� fin flr (perpendicular)or flr topping mixture—UL Des L211—rating also applies with IMPERIALBrand Gypsum Base, FIRECODE C Core, and veneer finish surface

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

333⁄4"

22"

���������������

221⁄2"����������

22"

201⁄2"

26"231⁄4"23"����������

213⁄8"

221⁄2"����������

B

26

Page 27: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 27

Ceilings

Fire-rated constructionCAC Physical data Folderrange† Construction detail Description & test no. Comments reference

2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies (continued)3/4" FR-83 or FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— SC2000 85—light fixt, air duct and speakers optional—2" precast concrete units & 3/4" SC1963noncomb insul over bar joists—UL Des P213

5/8" FR-4 or FR-83 or 3/4" FR-83 or FR-X1 acoust clg panels in DXL, DXLA, DXLZ, SC2000 86DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt, air duct and speakers SC1963optional—USG Drywall SuspensionSystem (DGL)—1/2" SHEETROCK Brand Gypsum Panels, FIRECODE C Core—susp grid with main runners and and cross tees 4’ o.c.—gypsum panels screw-att to grid-joints stag & fin—1" to 3" noncomb insul over 1" stl roof deck or 1-1/2" stl floor and formunits over bar joists—UL Des P237—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

5/8" FR-4; 5/8" or 3/4" FR-83; or 3/4" FR-X1 acoust clg panels in DXL, DXLA, SC2000 87DXLZ, DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt, air duct and SC1963speakers optional—insul clg membrane below joists—2" insul conc on corrug stl deck deck over bar joists—UL Des P241

1-1/2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies5/8� FR-4, M or FR-81; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels or SC2000 881/2� FC-CB gypsum lay-in tile in DXL or DXLA Susp Exp Grid Syst-—light fixt SC1963and speakers optional—2-1/2� concrete on Fluted or cellular stl deck—UL Des D209

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXLT, DXLTA, DXLTZ or When AP-1 clg panels are used, the SC2000 89DXLTZA Susp Exp Grid Syst—light fixt, air duct and speakers optional— fire rating is limited to 1-hr. SC19632-1/2� concrete on corrug stl deck over bar joists—UL Des G262

5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXLF (with CM or CP When AP-1 clg panels are used, the SC2000 90metal ceiling Panels) Susp Exp Grid Syst—light fixt, air duct and speakers fire rating is limited to 1-hr. SC1963optional—2-1/2� concrete on corrug stl deck over bar joists—UL Des G264

5/8� or 3/4� FR-83 or 3/4� AP or FR-X1 acoust clg panels in DXL, DXLZ or SDXL SC2000 91Susp Exp Grid Syst—light fixt, air duct and speakers optional—2-1/2� conc on SC1963corrug steel deck over bar joists—UL Des G267

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

2111⁄16"

2111⁄16"�����

�����227⁄16"

163⁄8"

38"

��������

32"

23"

BB

Page 28: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Ceilings

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

1-1/2-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies (continued)5/8� or 3/4� FR-83 or 3/4� FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp SC2000 92Exp Grid Syst—light fixt, air duct and speakers optional—1-1/2� poured gypsum SC19631-1/2� poured gypsum roof deck over 1/2� gypsum form board or 2� laminated gypsum plank building units over bar joists—UL Des P207

5/8� FR-4; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels in DXL, DXLA, When AP clg panels are used, the fire rating is limited SC2000 93DXLZ, DXLZA, SDXL, SDXLA or ZXLA or DXLP (with Types PAR, PARP, PAS, PASP, to 1-hr. SC1963PSR, PSRP, PSS & PSSP metal ceiling pans), Direct-Hung Susp Exp Grid Syst—light fixt, air duct and speakers optional— 1-1/2� stl roof deck & 5/8� SHEETROCKBrand Gypsum Panels, FIRECODE Core and a wide variety of roof insul products over bar joists—alt design 1/2� DUROCK Brand cement panel in place of gypsum panels—UL Des P230

5/8� FR-4 or FR-83; or 3/4� FR-83 or FR-X1 acoust clg panels in DXL, DXLA, SC2000 94DXLZ, DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt, air duct and SC1963speakers optional—USG Drywall Suspension System (DGL)—1/2� SHEETROCKBrand Gypsum Panels, FIRECODE C Core—susp grid with main runners and and cross tees 4’ o.c.-gypsum panels screw-att to grid—joints stag & fin—1-1/2�poured gypsum roof deck over 1/2� gypsum form board over bar joists—UL Des P239—rating also applies with IMPERIAL Brand Gypsum Base, FIRECODE C Core, and veneer finish surface

3/4� FR-83 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt, SC2000 95air duct and speakers optional—1-5/8� and 1-7/8� noncomb insul (two layers) over 2� SC1963poured gypsum roof deck over 1/2� gypsum form board or 2� laminated gypsum plank building units over bar joists—UL Des P242

5/8� FR-4; or 3/4� FR-83 or FR-81acoust clg panels in DXL, DXLA, DXLZ, DXLZA, SC2000 96SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt and air duct optional— 6� glassfiber batt insul over back of ceiling panels and grid system-metal roof deck over 4�glass fiver batt insul over Z-purtins—UL Des P268

5/8� FR-4 or FR-83; or 3/4� FR-83 or FR-X1 acoust clg panels in DXL, DXLZ, SC2000 97or SDXL Susp Exp Grid Syst—light fixt and air duct optional—min. 2-1/4�insul concrete over 1� foamed plastic insul over stl roof deck—UL Des P269

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

283⁄16"to

297⁄8"

291⁄8"

24"

37"

�����275⁄8"

231⁄2"235⁄8"

B

28

Page 29: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 29

Ceilings

Fire-rated constructionCAC Physical data Folderrange† Construction detail Description & test no. Comments reference

1-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies3/4� FR-83 min acoust tile in Concealed Accessible Grid Syst— SC2000 98light fixt and air duct optional—1� nom wd sub (diagonally) or 15/32� wd sub SC1963(perpendicular) over wd joists 16� o.c.; 1� nom or 19/32� fin flr (perpendicular) or flr topping mixture—UL Des L006

5/8� FR-81, FR-4 or M; 5/8� or 3/4� FR-83; or 3/4� FR-X1 acoust clg panels SC2000 99in DXL, DXLZ, or SDXL Susp Exp Grid Syst—light fixt, air duct and speakers SC1963optional—1� nom wd suband fin flr over 2 x 10 wd joists—UL Des L202

5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels or 1/2" FC-CB gypsum clg SC2000 100panels in DXL, DXLA, DXLZ, DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst SC1963—light fixt and air duct optional—1" nom wd sub and fin flr over 2 x 10 wdjoists—UL Des L206

5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLA, DXLZ, DXLZA, SC2000 101SDXL or SDXLA Susp Exp Grid Syst—light fixt and speakers optional—2" conc on SC1963riblath over bar joists—UL Des G201

5/8" FR-4 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— light SC2000 102fixt, air duct and speakers optional—1" nom wd sub (diagonally) or 15/32" SC1963wd sub (perpendicular) over wd joists 16" o.c.; 1" nom or 19/32" fin flr (perpendicular) or flr topping mixture—UL Des L212

5/8" M, 5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLA, DXLZ, SC2000 103DXLZA, SDXL, SDXLA or ZXLA, Susp Exp Grid Syst—1-1/2" stl roof deck & 3/4" SC1963noncomb insul over bar joists—UL Des P201

5/8" M, 5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in Susp Exp Grid Syst— SC2000 104light fixt and air duct optional—7/8" stl roof deck & 1" noncomb insul over bar SC1963joists—UL Des P202

3/4" FR-83 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— SC2000 105light fixt, air duct and speakers optional— 1-1/2" stl roof deck & 1" noncomb SC1963insul over bar joists—alt. Design 1/2" DUROCK Brand cement panel in place of gypsum panels, 24" plenum depth, for restrained assembly—1 hr. fire rating—UL Des P214

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

26"24"

201⁄2"

22"221⁄8"

215⁄8"213⁄4"

251⁄2"

181⁄2"����������

����������

����������

225⁄8"213⁄8"

201⁄4"

BB

Page 30: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Ceilings

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

1-Hour Rated Acoustical Floor and Roof-Ceiling Assemblies (continued)3/4" FR-83 or FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— SC2000 106light fixt, air duct and speakers optional—2" laminated gypsum plank building units SC1963over 1-5/8" and 1-7/8" noncomb insul (two layers) over bar joists—UL Des P228

3/4" FR-83 or FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— SC2000 107—light fixt, air duct and speakers optional—1" to 8" rigid foamed plastic insulation SC1963over 1-1/2" poured gypsum roof deck over 1/2" gypsum form board or 2" laminatedgypsum plank building units over bar joists—UL Des P229

5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp Exp SC2000 108Grid Syst—light fixt, air duct and speakers optional— 1-1/2" stl roof deck & 1/2" SC1963SHEETROCK Brand Gypsum Panels & insul over bar joists—UL Des P235

5/8" FR-4 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst— light fixt, SC2000 109air duct and speakers optional—6" insul batts over clg—1" fluted stl roof deck & SC1963insul over bar joists—UL Des P238

5/8" FR-4 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt, air SC2000 110duct and speakers optional—1-1/2" poured gypsum roof deck over 1/2" gypsum form SC1963board or 2" laminated gypsum plank building units over bar joists—UL Des P244

5/8" FR-4 acoust clg panels in DXL, DXLZ or SDXL Susp Exp Grid Syst—light fixt, air SC2000 111duct and speakers optional—6" insul batts over clg— 3/4" noncomb insuland 2" metal- SC1963edge conc plank over bar joists—UL Des P245

5/8" FR-81 or 5/8" or 3/4" FR-83 acoust clg panels in DXLF (with CM or CP metal SC2000 112ceiling Panels) Susp Exp Grid Syst—light fixt and air duct optional—6" insul batts SC1963over clg—1-1/2" stl roof deck & 5/8" SHEETROCK Brand Gypsum Panels & insulover bar joists—UL Des P254

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

�����227⁄8"

�����303⁄4"

28"

26"24"

201⁄2"

20"

231⁄2"

B

30

Page 31: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 31

Ceilings

Fire-rated constructionCAC Physical data Folderrange† Construction detail Description & test no. Comments reference

1-Hour Rated Ceilings Mineral Fiber Surfaces (continued)5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLZ or SDXL Susp SC2000 113Exp Grid Syst—light fixt, air duct and speakers optional— 2" vermiculite conc & SC1963foamed plastic insul & corrug stl roof deck over bar joists—UL Des P246

5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLA, DXLZ, DXLZA, SC2000 114SDXL or SDXLA Susp Exp Grid Syst—light fixt, air duct and speakers optional— SC19632" vermiculite conc & foamed plastic insul & corrug stl roof deck over bar joists—UL Des P255

5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLA, DXLZ, DXLZA, SC2000 115SDXL or SDXLA Susp Exp Grid Syst—light fixt and air duct optional— 2-7/16" SC1963noncomb insul (two layers) over 1/2" gypsum sheathing over stl roof deck over "C" joists—UL Des P257

5/8" M, 5/8" or 3/4" FR-83 or 3/4" FR-X1 acoust clg panels in DXL, DXLA, DXLP SC2000 116(with Types PAR, PARP, PAS, PASP, PSS, PSSP, PSR, & PSRP metal ceiling pans), SC1963DXLZ, DXLZA, SDXL, SDXLA or ZXLA Susp Exp Grid Syst—light fixt and air duct optional—1" to 2" noncomb insul (two layers) over stl roof deck over barjoists—UL Des P267

3/4-Hour Rated Acoustical Floor and Roof-Ceiling Assembly5/8" M; 5/8" or 3/4" FR-83; or 3/4" FR-X1 acoust clg panels in Susp Exp Grid SC2000 117Syst—light fixt and air duct optional— 7/8" stl roof deck & 1" noncomb insul SC1963over bar joists—UL Des P203

Notes: For the purpose of simplifying the information on these fire-rated acoustical ceiling assemblies, unrestrained ratings only are provided. For restrained assemblies and unrestrained beam ratings, see the UL Fire ResistanceDirectory. Also, see the UL Fire Resistance Directory for specific ceiling tile sizes and other assembly details. For a list of ceiling product codes to UL Type Designation in test descriptions, see “UL Type Designation, Acoustical Tile andPanel Products” and “UL Type Designation, Acoustical Suspension Products” on page 43.

Class A Acoustical Ceiling Assemblies35 ACOUSTONE “F’’ 3/4� x 12� x 12� or 12� x 24� min. acoust tile on Basic concealed spline acoustical tile SC2000 118to Concealed Z-runner Syst—ASTM E84 Class A surfaces system; STC estimated SC196339clg. wt. 1.3

35 5/8� or 3/4� x 24� x 24� or 24� x 48� acoust clg panels in Susp Exposed Basic Class A lay-in panels; SC2000 119to Grid Syst—ASTM E84 Class A surfaces NRC varies with pattern SC196339

clg. wt. 1.0

40 AURATONE 5/8� x 24� x 48� acoust clg panels in Susp Exp Grid Syst— Sound test USG-820406 includes SC2000 120to contin over partn—3� SAFB over clg—ASTM E84 Class A surfaces blankets extending 4 ft. each side of SC196344 partition

clg. wt. 1.5

*For acoustical ceilings, fire ratings are based on tests of assemblies between vertical adjacent spaces. However, sound tests are conducted between horizontally adjacent spaces.†Per E1414 test procedures for horizontal adjacent spaces.CAC replaces CSTC.

����

221⁄4"

22" to231⁄8"

283⁄16"

309⁄16"25"

�����

BB

Page 32: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

32

Structural Fireproofing

Fire-rated constructionColumn Physical data Foldertype Construction detail Description & test no. Comments reference

Column Fireproofing

4-Hour Rated ApplicationsW14 Gypsum Drywall Fire Protection—2 layers 1/2� SHEETROCK Brand Gypsum SA923 1x228 Panels, FIRECODE C Core, around col—panels screw att to 1-5/8� 25 ga

steel studs at corners—met corner beads—joints fin—UL Des X507

W14 Gypsum Base & Veneer Finish Fireprfg—2 layers 1/2� IMPERIAL Brand SA920 2x228 Gypsum Base, FIRECODE C Core, around col—base screw att to 1-5/8�

25 ga steel studs at corners—met corner beads—1/16� veneer finish—UL Des X507

W10 Metal lath & plaster—3.4# diamond mesh metal furred 1/2� from face of SA920 3x49 column—1-7/8� Structo-Lite plaster with fill between flange face &

lath—perlite aggregate bearing UL Label—UL Des X405

W10 Metal lath & plaster—3.4# self-furring diamond mesh metal lath SA920 4x49 wrapped around column—1-3/4� Structo-Lite plaster or 100:2-100:3

gypsum-perlite plaster—perlite aggregate bearing UL Label—UL Des X402

3-Hour Rated ApplicationsW4x13 Gypsum Drywall Fire Protection—3 layers 3/4� SHEETROCK Brand Gypsum SA923 5W6x15.5 Panels, ULTRACODE Core, around col, with second layer wrapped withW10x49 no. 18 SWG steel wire spaced 24� o.c.—panels screw att to 1-5/8� 25 ga

steel studs at corners—met corner beads—joints fin—UL Des X528

W14 Gypsum Drywall Fire Protection—1/2� SHEETROCK Brand Gypsum Panels, SA923 6x228 FIRECODE C Core, around col—double layer over ea web face—panels

screw att to 1-5/8� 25 ga steel studs at col corners—met corner beads—joints fin—UL Des X514

W14 Gypsum Base & Veneer Finish Fireprfg—1/2� IMPERIAL Brand SA920 7x228 Gypsum Base, FIRECODE C Core, around col—double layer over ea web

face—base screw att to 1-5/8� 25 ga steel studs at col corners—met corner beads—1/16� veneer finish—UL Des X514

W10 Gypsum Drywall Fire Protection—3 layers 1/2� SHEETROCK Brand Gypsum SA923 8x49 Panels, FIRECODE C Core, around col—triple layer over ea flange

end—inner layers on flange face separ by 1-5/8� 25 ga steel studs & screw att—met beads on corners—joints fin—UL Des X515

W10 Gypsum Base & Veneer Finish Fireprfg—3 layers 1/2� IMPERIAL Brand SA920 9x49 Gypsum Base, FIRECODE C Core, around col—triple layer over ea flange

end—inner layers on flange face separ by 1-5/8� 25 ga steel studs & screw att—met beads on corners—1/16� veneer finish—UL Des X515

W10 Metal lath & plaster—3.4# self-furring diamond mesh metal lath SA920 10x49 wrapped around column—1-3/8� 100:2-100:3 gypsum-perlite plaster or

Structo-Lite plaster—UL Des X402

������������������������

����

����

����

����

���

���

����

����

����

����

���

���

47⁄8"

21⁄4"

C

Page 33: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Structural Fireproofing

Fire-rated constructionColumn Physical data Foldertype Construction detail Description & test no. Comments reference

2-Hour Rated ApplicationsW4x13 Gypsum Drywall Fire Protection—2 layers 3/4� SHEETROCK Brand Gypsum SA923 11W6x15.5 Panels, ULTRACODE Core, around col—panels screw att to 1-5/8� 25 ga W10x49 steel studs at corners—met corner beads—joints fin—UL Des X528

W14 Gypsum Drywall Fireprfg—1 layer—1/2� SHEETROCK Brand Gypsum SA923 12x228 Panels, FIRECODE C Core, around col—panel screw att to 1-5/8� 25 ga

steel studs at col corners—met corner beads—joints fin—UL Des X521

W14 Gypsum Base & Veneer Finish Fireprfg—1/2� IMPERIAL Brand Gypsum Base, SA920 13x228 FIRECODE C Core, around col—base screw att to 1-5/8� 25 ga steel stud at col

corners—met corner beads—1/16� veneer finish—UL Des X521

W10 Gypsum Drywall Fire Protection—2 layers 1/2� SHEETROCK Brand Gypsum SA923 14X49 Panels, FIRECODE C Core, around col—double layer over ea flange

end—double layer on flange faces separ by 1-5/8� 25 ga steel stud & screw att—met beads on corners—joints fin—UL Des X518

W10 Gypsum Base & Veneer Finish Fireprfg—2 layers 1/2� IMPERIAL Brand SA920 15x49 Gypsum Base, FIRECODE C Core, around col—double layer over ea flange

end—double layer on flange faces separ by 1-5/8� 25 ga steel studs & screw att—met beads on corners—1/16� veneer finish—UL Des X518

Varies Gypsum Drywall Fire Protection—3 layers 1/2� SHEETROCK Brand Gypsum Rating also applies to tapered or SA923 16Panels, FIRECODE C Core, around col—triple layer over ea flange constant-section prefabricated metal end—inner layers on flange face separ by 1-5/8� 25 ga steel studs & building columnsscrew att—met beads on corners—joints fin—UL Des X524

Varies Gypsum Base & Veneer Finish Fireprfg—3 layers 1/2� IMPERIAL Brand Rating applies to tapered or SA920 17Gypsum Base, FIRECODE C Core, around col—triple layer over ea flange constant-section prefabricated metal end—inner layer on flange face separ by 1-5/8� 25 ga steel studs & screw building columnsatt—met beads on corners—1⁄16� veneer finish—UL Des X524

W10 Metal lath & plaster—3.4# self-furring diamond mesh metal lath SA920 18x49 wrapped around column—1� 100:2-100:3 gypsum-perlite plaster or

Structo-Lite plaster—perlite aggregate bearing UL Label—UL Des X402

1-Hour Rated ApplicationW10 Metal lath & plaster—3.4# self-furring diamond mesh metal lath SA920 19x49 wrapped around column—3/4� 100:2-100:3 gypsum-sand

plaster—BMS-92

Beam Fireproofing4 hr. W12 Metal Lath & Plaster Caged Beam Fireprfg—3.4# self-furring diamond Suitable for protection of beams and SA920 20

x58 mesh metal lath enclosing beam—1-1/2� 100:2 gypsum-perlite girdersplaster— UL Des D403

����������������

���

���

���

���

���

���

���

���

41⁄8"

11⁄2"

C

SA100/USG Corporation 33

2 hr. W8(beam x24only)

Page 34: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Structural Fireproofing

Fire-rated constructionColumn Physical data Foldertype Construction detail Description & test no. Comments reference

Beam Fireproofing (continued)

3 hr. W8 Gypsum Drywall Caged Beam Fireprfg—1-5/8� stl run chan brackets 24� SA923 21(beam x24 o.c.—7/8� x 1-3/8� corner angles att to brackets—3 layers 5/8� SHEETROCKonly) Brand Gypsum Panels, FIRECODE Core, att with Type S screws—1�

20 ga hex mesh on bottom over middle layer—met beads on corners—joints fin—2-1/2� conc deck on fluted stl flr—UL Des N505

3 hr. W8 Gypsum Base & Veneer Finish Caged Beam Fireprfg—1-5/8� stl run chan Fire rating for restrained assembly; SA920 22(beam x24 brackets 24� o.c.—1/8� x 1-3/8� corner angles att to chan brackets— 2 hr rating for unrestrained assemblyonly) 3 layers 5/8� IMPERIAL Brand Gypsum Base, FIRECODE Core, att with Type S

screws—1� 20 ga hex mesh on bottom over middle layer—met beads on corners—joints taped—1/16� veneer finish—2-1/2� conc deck on fluted stl flr—UL Des N505

2 hr. W8 Gypsum Drywall Caged Beam Fireprfg—1-5/8� stl run chan brackets 24� SA923 23(beam x24 o.c.—1-3/8� x 7/8� corner angles att to chan brackets—dbl layer 5/8�only) SHEETROCK Brand Gypsum Panels, FIRECODE Core, att with Type S

screws—met beads on corners—joints fin—2-1/2� conc deck on fluted stl flr—UL Des N501 (f)—UL Des N502

Gypsum Base & Veneer Finish Fireprf—1-5/8� stl run chan brackets—dbl SA920 24laye 5/8� IMPERIAL Brand Gypsum Base, FIRECODE Core, att with Type S screws—met beads on corners—1/16� veneer finish—2-1/2� conc deck on fluted stl flr—UL Des N501—UL Des N502

33

CC

Page 35: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Exterior Walls

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

2-Hour Rated Assemblies (Non-Load-Bearing)Steel Stud—1/2� DUROCK Brand Cement Panel—base layer 1/2� SHEETROCK Brand Gypsum SA700 1Panels, water-resistant, FIRECODE C Core, both sides—board screw-attached 8� o.c. to 3-5/8� 20 ga min steel non-load-bearing studs 16� o.c.—3� SAFB—joints taped—alt design, double-layer 1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, interior—UL Des U474

wt. 11

Double layer 5/8� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core, exterior side— Based on 3-5/8� studs and SA700 2Double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, interior— 5/8� SHEETROCK Brand gypsum2-1/2� or 3-5/8� studs 24� o.c—base layer screw att—face layer screw att— panels, FIRECODE C Core—joints stag & fin or unfin—perimeter caulked—UL Des U411 or U419 BBN-770408

56 STC—Based on 3-5/8� studs and3� insulation—USG-840818wt. 12

Double layer 5/8� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core,exterior side— Rating also applies with SHEETROCK SA700 33-1/2� 20 ga struc studs 24� o.c.—dbl layer 5/8� SHEETROCK Brand Gypsum Panels, Brand Gypsum Panels, water-resistant, SA923FIRECODE Core, interior—base layer att with 1� Type S-12 screws 12� o.c.— FIRECODE Core, gypsum panel exteriorface layer att with 1-5/8� Type S-12 screws 12� o.c.—load-bearing up to 100%allowable stud axial load when min. 2� Thermafiber SAFB is used in stud cavities;otherwise load-bearing up 80% allowable steel axial load—UL Des U423 or U425

wt. 12

1/2� DUROCK Brand cement panel—base layer 5/8� SHEETROCK Brand Gypsum SA700 4Sheathing, FIRECODE Core—2 x 4 16� o.c.—3� SAFB—joints taped and treated—double-layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des. U308

wt. 12

Exterior Curtain Wall—3-5/8� 20 ga steel studs 16� o.c.—1/2� gypsum Systems offer wide selection of exterior SA923 5sheathing—self-furring metal lath—1� cement-lime stucco exterior side—3� and interior surfaces, utilizing insul blankets betw studs—5/8� SHEETROCK Brand Gypsum Panels, foil-back, conventional materialsFIRECODE C Core, or IMPERIAL Brand Gypsum Base, FIRECODE C Core, and1/16� IMPERIAL Brand veneer finish interior—T-4851-OSU

Exterior Curtain Wall—1� SHEETROCK Brand Gypsum Liner Panels set betw steel Rating also applies with IMPERIAL Brand SA923 6C-H studs 24� o.c. on exterior side—2 layers SHEETROCK Brand Gypsum Panels, Gypsum Base, FIRECODE C Core, and veneer FIRECODE C Core, screw att on interior—joints fin—U of C 4-2-75 finish interior

2-Hour Rated Assemblies (Load-Bearing)Double layers 1/2� (or 5/8�) DUROCK Brand Cement Panel—3-1/2� studs 16� o.c.—3� SA700 7SAFB—joints taped and treated—2 layers 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des. U404

wt. 11

Wd Stud—double layer 5/8� SHEETROCK Brand Type X exterior sheathing—double layer SA700 85/8� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core, or SHEETROCK Brand Gypsum SA924Panels, Water-Resistant, FIRECODE Core, interior—2x4 16� o.c.—base layer att with 1-7/8�nails 6� o.c.—face layer att with 2-3/8� nails 8� o.c. joints— exp of side fin—UL Des U301

wt. 12

Wd Stud—double layer 1/2� layers 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE FIRECODE Base and veneer finish SA700 9Core, interior side—2x4 16� o.c.—sheathing appl horiz with 11d galv nails 6� o.c. interior SA924—SHEETROCK Brand Gypsum Panels, appl horiz or vert with nails 8� o.c.—joints stag & fin—UL Des U302

wt. 44

1-1/2-Hour Rated Assemblies (Non-Load-Bearing)Double layer 1/2� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core, exterior side— SA700 103-1/2� 20 ga struc studs 24� o.c.—dbl layer 1/2� SHEETROCK Brand Gypsum Panels, SA923FIRECODE Core, interior—base layers att with 1� Type S-12 screws 12� o.c.—face layers att with 1-5/8� Type S-12 screws 12� o.c.—load-bearing up to 100% allowable stud axial load—UL Des U423 or U425

wt. 10

1/2� SHEETROCK Brand Gypsum Sheathing, exterior side—3-1/2� 20 ga struc studs Rating applicable to fire exposure on SA923 1124� o.c.—double layer 5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, interior— interior face onlybase layers att with 1� Type S-12 screws 16� o.c.—face layers att with 1-5/8� Type S-12 screws 16� o.c.—load-bearing up to 100% allowable stud axial load—UL Des U424 or U425

��������������51⁄4"

��������

�������

��������������51⁄2"

�������

��������������

�������

������������������10"

����������������������������

��������������6"

����������������������

��������������������������������

53⁄4",6"

�������31⁄2"�������

����������

��������

�������

���������������������

53⁄4"

�����������

��������������������������������

57⁄8",6"

����������������

��������������

6"�������

��������������

�������

���������������������41⁄8"

61⁄8"

�������

��������������

�����������������������������

55⁄8"

SA100/USG Corporation 35

D

Page 36: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Exterior Walls

Fire-rated constructionPhysical data FolderConstruction detail Description & test no. Comments reference

1-Hour Rated Assemblies (Non-Load-Bearing)5/8� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core, exterior side—3-1/2� Rating also applies with SHEETROCK SA700 1220 ga struc studs 24� o.c.—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, Brand Gypsum Panels, water-resistant, SA923interior—load-bearing up to 100% allowable stud axial load— FIRECODE Core, exteriorUL Des U419

wt. 6

3-1/2� 20 ga struc studs 24� o.c.—1/2� gypsum sheathing—1� extruded polystyrene insul SA923 13installed horiz—1/2� cedar plywood exterior—3-5/8� insul blkts betw studs—5/8� SHEETROCKBrand Gypsum Panels, FIRECODE C Core, interior—joints fin—CEG 12-7-79

1/2� DUROCK Brand Cement Panel and1/4� ceramic tile exterior side— board screw- SA700 14attached 8� o.c. to 3-5/8� 20 ga. min steel non-load-bearing studs spaced 16� o.c.—3� SAFB between studs—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or IMPERIAL Brand Gypsum Base, FIRECODE Core, and 1/16� IMPERIAL Brand finish interior—UL Des U442

wt. 14

1/2� DUROCK Brand Cement Panel—3-5/8� 20 ga. min. steel non-load-bearing SA700 15studs 16� o.c.—3� min. SAFB—board att 8� o.c.—joints fin—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—UL Des U457

wt. 7

1/2� DUROCK Brand cement panel—1-5/8� 20 ga. min. steel non-load-bearing SA700 16studs 16� o.c. in two rows with horiz braces—1-1/2� SAFB in both stud cavities—board att 8� o.c.—joints fin—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core—UL Des U458

wt. 7

5/8� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core, exterior side—5/8� SHEETROCK USG-860808 SA700 17Brand Gypsum Panels, FIRECODE Core, interior—3-5/8� studs 24� o.c.—joints finished— Based on 3�perimeter caulked—UL Des U419 or U465 insulation in cavity

—SA-870717

wt. 6, wt. 5

Steel Stud—1/2� DUROCK Brand Cement Panel—base layer 5/8� SHEETROCK Brand Gypsum SA700 18Panels, water-resistant, FIRECODE Core—board screw-attached 8� o.c. to 3-1/2� 20 ga. min. steel load-bearing studs 16� o.c.—3� SAFB—joints fin—5/8� SHEETROCK BrandGypsum Panels, FIRECODE Core, interior—UL Des U473

wt. 9

1-Hour Rated Assemblies (Load-Bearing)1/2� DUROCK Brand cement panel—base laye 15/32� plywood—2 x 4 16� o.c.—3� SA700 19SAFB—joints fin—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, other side—UL Des. U303

wt. 9 psf

5/8� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, interior side—1� extruded SA924 20polystyrene insul sheathing and 1/2� plywd siding—2x4 16� o.c.—3-1/2� insul blkts—gypsum panels appl vert—joints fin—UL Des U330

1/2� DUROCK Brand Cement Panel and 1/4� ceramic tile exterior—board att 8� o.c.— SA700 212 x 4 wood load bearing studs spaced 16� o.c.—3-1/2� insul between studs—5/8� SHEETROCK Brand Gypsum Panels, FIRECODE Core, or IMPERIAL Brand Gypsum Base,FIRECODE Core, and 1/16� IMPERIAL Brand finish interior—UL Des U329

wt. 15

5/8� SHEETROCK Brand Type X Exterior Sheathing—5/8� SHEETROCK Brand Gypsum Based on 16� stud spacing SA700 22Panels, FIRECODE Core or SHEETROCK Brand Gypsum Panels, water-resistant, FIRECODE and screws 6� o.c.—Core, interior side—2x4 16� or 24� o.c.—panels nailed 7� o.c.—joints exp or fin— USG-30-FT-G&Hperim caulked—UL Des U305 based on 16� stud spacing—UL Des U314 Based on 24� studbased on 24� stud spacing, joints fin spacing—USG-860807

Based on 24� stud spacing & wt. 7 3� insulation—BBN 700725

1/2� DUROCK Brand cement panel—3-1/2� studs 16� o.c.—3� SAFB—5/8� SHEETROCK SA700 23Brand Gypsum Panels, FIRECODE Core, other side—joints fin—UL Des. U404

wt. 7 psf

45-Min. Rated Assembly1/2� SHEETROCK Brand Gypsum Sheathing, FIRECODE Core—3-1/2� 20 ga struc studs SA700 2424� o.c.—1/2� SHEETROCK Brand Gypsum Panels, FIRECODE C Core, interior side— SA923load-bearing up to 100% allowable stud axial load—UL Des U423 or U425

wt. 5

�������41⁄2"

�������

�����������

����������������

45⁄8",43⁄4"

�������

43⁄4"�������

�������������������5" �������� �����������

���yyy��������������

55⁄8"

�����������

����������������

51⁄8",51⁄4"

�������

������������������

51⁄4"

�������47⁄8"27⁄8"�������

�������

����������������������

47⁄8"

��������

�����������43⁄4"

��������

�������������������

51⁄8"

������

��������������

���yyy�������61⁄8"

��������������

43⁄4"

��������������

CD

36

Page 37: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 37

Exterior Wall Furring

Physical data FolderConstruction detail Description Comments reference

Drywall AssembliesMetal furring channels 24� o.c., 1/2� SHEETROCK Brand Gypsum Panels, Good vapor retarder, no limiting height SA923 1foil-back, screw attached, joints finished

Wood furring strips 16� o.c., 1/2� SHEETROCK Brand Gypsum Panels, foil-back, Surface not isolated from structural SA924 2joints finished stresses

Z-furring channels appl vert 24� o.c., THERMAFIBER blankets betw Suitable for up to 3� thick insulation; SA923 3chan, 1/2� SHEETROCK Brand Gypsum Panels, foil-back, screw good vapor retarder; no limiting height SA924attached to channels, joints finished

Steel studs 24� o.c., 1/2� SHEETROCK Brand Gypsum Panels, foil-back, Free standing for pipe chase clearance; SA923 4screw-attached, joints finished good vapor retarder

Z-furring channels appl vert 24� o.c., rigid plastic foam insulation Suitable for up to 3� thick insulation no SA923 5betw chan, 1/2� SHEETROCK Brand Gypsum Panels, foil-back, appl vert and limiting heightscrew-attached to channels, joints finished

Plaster AssembliesMetal furring channels 16� o.c., 1/2� IMPERIAL Brand Gypsum Base, foil-back, Good vapor retarder, no limiting height SA920 6screw-attached to channels, 1/16� veneer finish

Steel studs 16� o.c. set in runners, 1/2� IMPERIAL Brand Gypsum Base, foil-back, Free-standing, allows for pipe chase SA920 7screw-attached to studs, 1/16� veneer finish clearance, good vapor retarder

Z-furring channels appl vert 24� o.c., THERMAFIBER blankets betw Good vapor retarder, no limiting height SA920 8chan, 1/2� IMPERIAL Brand Gypsum Base, foil-back, screw-attached to channels, 1/16� veneer finish

Z-furring channels appl vert 24� o.c., rigid plastic foam insulation Suitable for up to 3� thick insulation, no SA920 9betw chan, 1/2� IMPERIAL Brand Gypsum Base, foil-back, screw-attached to channels, limiting height1/16� veneer finish

Steel studs 16� o.c. set in runners, 3/8� ROCKLATH base attached with 1� Type S Freestanding; allows for pipe chase SA920 10screws, 1/2� sanded basecoat plaster, lime putty finish clearance; good vapor retarder.

Z-furring channels applied vertically 16� or 24� o.c., THERMAFIBER Noncombustible; system with mineral SA920 11blankets between channels, 3/8� ROCKLATH base attached with fiber insulation; suitable for up to 3�1� Type S screws, 1/2� sanded basecoat plaster, lime putty thick insulation; no limiting heightfinish

Z-furring channels applied vertically 16� or 24� o.c., rigid plastic Suitable for up to 3� thick insulation; no SA920 12foam insulation between channels, 3/8� ROCKLATH base attached with 1� Type S limiting heightscrews, 1/2� sanded basecoat plaster, lime putty finish���yyy��������������

������17⁄8"

��������������������

17⁄8"

���������������������������

varies

���yyy�������������

11⁄2"

�������������

11⁄2"

�������������

varies

�������������

13⁄8"

���yyy�������������

11⁄2"

�������������

varies

�������������

11⁄2"

�������������

2"

�������������

13⁄8"

E

Page 38: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

38

Codes for Type of Floor, Roof orWall: CF-Concrete Floor, CW-Concrete Wall, FSD-Fluted SteelDeck, GW-Gypsum Wall, WF-Wood Floor.

Codes for Firestopping Material:Type A-FIRECODE Acrylic FirestopSealant (regular ); Type A-SP-FIRECODE Acrylic Firestop SpraySealant (Type SA); Type AS—SHEETROCK® Brand AcousticalSealant; Type IA-FIRECODE IAIntumescent Acrylic FirestopSealant; Type FC-FIRECODECompound; Type SS-THERMAFIBER SMOKE SEALCompound; Wrap-TREMSTOP DIntumescent Wrap Strips.

(1) Pipe covering material. (2) Minimum depth dependent

upon annular spacedimensions.

(3) Optional. (4) Ceramic fiber. (5) 2-hr. wall. (6) 2-hr. (two layers 7/8�

backer rod); 1-hr. (bondbreaker tape).

(7) Two layers 7/8� backer rod.

Through-Penetration FirestopsBF

Codes for Type of Floor, Roof orWall: CF-Concrete Floor, CW-Concrete Wall, FSD-Fluted SteelDeck, GW-Gypsum Wall, WF-Wood Floor.

Codes for Firestopping Material:Type A-FIRECODE Acrylic FirestopSealant (regular ); Type A-SP-FIRECODE Acrylic Firestop SpraySealant (Type SA); Type AS—SHEETROCK® Brand AcousticalSealant; Type IA-FIRECODE IAIntumescent Acrylic FirestopSealant; Type FC-FIRECODECompound; Type SS-THERMAFIBER SMOKE SEALCompound; Wrap-TREMSTOP DIntumescent Wrap Strips.

(1) Pipe covering material. (2) Minimum depth dependent

upon annular spacedimensions.

(3) Optional. (4) Ceramic fiber. (5) 2-hr. wall. (6) 2-hr. (two layers 7/8�

backer rod); 1-hr. (bondbreaker tape).

(7) Two layers 7/8� backer rod.

Type ofFloor, Firestopping Min. Max.

Penetrating Roof or Material Forming Annular Annular F T UL System FolderItem and Diameter Wall (Min. Depth) Material Space Space Rating Rating Number reference

Steel, Iron, Metallic

Steel or Iron Pipe, up to 6� CW, CF 1� Type SS(2) 3-1/2�, min. 4 pcf 3/8� 3/4� 3 0 C-AJ-1020 SA727 1Steel or Iron Pipe, up to 6� CW, CF 2� Type SS(2) 2-1/2�, min. 4 pcf 3/8� 1� 3 0 C-AJ-1020 SA727 2Steel or Iron Pipe up to 24� CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 1-15/16� 3 0 C-AJ-1081 SA727 3Steel or Iron Pipe up to 10� CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 4� 3 0 C-AJ-1081 SA727 4Steel or Iron Pipe up to 12� CW, CF 1/2� Type A 4�, min. 4 pcf 1/4� 1� 2 0 C-AJ-1347 SA727 5Steel or Iron Pipe up to 4� CW, CF 1/2� Type A 4�, min. 4 pcf 0� 7/8� 2 0 C-AJ-1347 SA727 6Steel or Iron Pipe up to 8� CW, CF 1� Type IA 4�, min. 4 pcf 1/2� 1-3/8� 2 0 C-AJ-1348 SA727 7Steel or Iron Pipe up to 8� CW, CF 1/2� Type A 4�, min. 4 pcf(1) 1/2� 1� 2 1 C-AJ-5146 SA727 8Insulated Steel or Iron Pipe up to 2� CW, CF 1� Type IA Foam Backer(1) 1/8� 1/4� 2 1 C-AJ-5147 SA727 9Insulated Steel or Iron Pipe up to 8� CW, CF 1� Type IA Foam Backer 1/2� 0�-1-3/8� 2 1-1/2 C-AJ-5148 SA727 10Steel or Iron Pipe up to 4� CW, CF 1� Type IA 3-1/2�, min., 4 pcf(1) 1/2� 1-1/2� 2 1/2-1 C-AJ-5149 SA727 11Steel or Iron Pipe up to 8� FSD 1/2� Type A 4�, min. 4 pcf 1/4� 1-5/8� 3 0 F-A-1020 SA727 12Insulated Steel or Iron Pipe up to 8� FSD 1/2� Type A 4�, min. 4 pcf(1) 1/4� 5/8� 3 1 F-A-5014 SA727 13Steel or Iron Pipe up to 8� WF 1/2� Type IA Foam Backer(3) 0� 7/8� 1 1/4 F-C-1069 SA727 14Insulated Steel or Iron Pipe up to 4� WF 1/2� Type IA Foam Backer(1) 0� 7/8� 1 3/4-1 F-C-5042 SA727 15Steel or Iron Pipe up to 12� CW, CF 1/2� Type IA Foam Backer 0� 1� 2 0 W-J-1091 SA727 16Steel or Iron Pipe up to 4� GW 1� Type FC 2-1/2�, min. 4 pcf 1/4� 2-1/4� 2 0 W-L-1027 SA727 17Steel or Iron Pipe up to 6� GW 1� Type FC 2-1/2�, min. 4 pcf 1� 1-5/8� 2 0 W-L-1027 SA727 18Steel or Iron Pipe up to 4� GW 1/2� Type FC 2-1/2�, min. 4 pcf 1/4� 1-5/8� 1 0 W-L-1039 SA727 19Steel or Iron Pipe up to 3-1/2� GW 1� Type FC — 1/4� 1-5/8� 2 0 W-L-1063 SA727 20Steel or Iron Pipe up to 4� GW 1� Type SS(2) 2-1/2�, min. 4 pcf 1/4� 1-1/4� 2 0 W-L-1064 SA727 21Steel or Iron Pipe up to 1� GW 1� Type FC 2-1/2�, min. 4 pcf 3/8� 1-5/8� 2 1-2 W-L-1065 SA727 22Steel or Iron Pipe up to 4� GW 1� Type FC — 1/4� 1-1/4� 1 0-1 W-L-1087 SA727 23Insulated Steel Pipe up to 4� GW 1/4� Type FC — 1/4� 1/2� 2 1 W-L-5043 SA727 24Insulated Steel Pipe up to 3-1/2� GW 1� Type FC — 1/2� 5/8� 2 3/4 W-L-5044 SA727 25Insulated Steel or Iron Pipe up to 4� GW 1� Type IA Foam Backer(1)(3) 0� 3/8� 2 1/2 W-L-5114 SA727 26Insulated Steel or Iron Pipe up to 8� GW 1/2� Type IA Foam Backer(1)(3) 1/4� 1-1/8� 1-2 1/2-1 W-L-5115 SA727 27Insulated Steel or Iron Pipe up to 8� GW 1� Type IA Foam Backer(3) 0� 1/2� 2 2 W-L-5116 SA727 28Conduit Nominal 4� CW, CF 1� Type SS(2) 3-1/2�, min. 4 pcf 3/8� 3/4� 3 0 C-AJ-1020 SA727 29Nominal 4� CW, CF 2� Type SS(2) 2-1/2�, min. 4 pcf 3/8� 1� 3 0 C-AJ-1020 SA727 30Steel Conduit up to 6� or Metallic CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 4� 3 0 C-AJ-1081 SA727 31

Tubing up to 4�

Nominal 4� CW, CF 1/2� Type A 4�, min. 4 pcf 0� 7/8� 2 0 C-AJ-1347 SA727 32Nominal 4� CW, CF 1/2� Type IA 4�, min. 4 pcf 1/2� 1-3/8� 2 0 C-AJ-1348 SA727 33Insulated Nominal 4� CW, CF 1� Type IA 3-1/2�, min. 4 pcf(1) 1/2� 1-1/2� 2 1/2-1 C-AJ-5149 SA727 34Nominal 4� FSD 1/2� Type A 4�, Min. 4 pcf 1/4� 1-5/8� 3 0 F-A-1020 SA727 35Nominal 4� WF 1/2� Type IA Foam Backer(3) 0� 7/8� 1 1/4 F-C-1069 SA727 36Nominal 2� Flex. Pipe WF 1/2� Type IA Foam Backer(3) 0� 7/8� 1 3/4 F-C-1070 SA727 37Nominal 4� CW 1/2� Type IA Foam Backer 0� 1� 2 0 W-J-1091 SA727 38Steel Conduit or Metallic GW 1� Type FC 2-1/2�, min. 4 pcf 1/4� 2-1/4� 2 0 W-L-1027 SA727 39

Tubing up to 4�

Nominal 4� or Metallic GW 1/2� Type FC 2-1/2�, min. 4 pcf 1/4� 1-5/8� 1 0-1 W-L-1039 SA727 40Tubing up to 4�

Steel Conduit or Metallic GW 1� Type FC — 1/4� 1-5/8� 2 0 W-L-1063 SA727 41Tubing up to 3-1/2�

Steel Conduit or Metallic GW 1� Type SS(2) 2-1/2�, min. 4 pcf 1/4� 1-1/4� 2 0 W-L-1064 SA727 42Tubing up to 4�

Nominal 1� or Metallic GW 1� Type FC 2-1/2�, min. 4 pcf 3/8� 1-5/8� 2 2 W-L-1065 SA727 43Tubing up to 1�

Nominal 4� or Metallic GW 1� Type FC — 1/4� 1-1/4� 1 0-1 W-L-1087 SA727 44Tubing up to 4�

Page 39: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 39

Type ofFloor, Firestopping Min. Max.

Penetrating Roof or Material Forming Annular Annular F T UL System FolderItem and Diameter Wall (Min. Depth) Material Space Space Rating Rating Number reference

Copper Pipe up to 6� CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 4� 3 0 C-AJ-1081 SA727 45Tubing and Pipe up to 4� CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 4� 3 0 C-AJ-1081 SA727 46Tubing and Pipe up to 4� CW, CF 1/2� Type A 3�, min. 6 pcf(4) 0� 7/8� 2 0 C-AJ-1347 SA727 47Tubing and Pipe up to 4� CW, CF 1� Type IA 4�, min. 4 pcf 1/2� 1-3/8� 2 0 C-AJ-1348 SA727 48Insulated Tubing and Pipe up to 4� CW, CF 1/2� Type A 4�, min. 4 pcf 3/8� 1-1/2� 1-1/2-2 1/2-1 C-AJ-5146 SA727 49Insulated Tubing and Pipe up to 2� CW, CF 1� Type IA Foam Backer 1/8� 1/4� 2 1 C-AJ-5147 SA727 50Insulated Tubing and Pipe up to 4� CW, CF 1� Type IA 3-1/2�, min. 4 pcf 1/2� 1-1/2� 2 1/2-1 C-AJ-5149 SA727 51Tubing and Pipe up to 4� FSD 1/2� Type A 4�, min. 4 pcf 1/4� 1-5/8� 3 0 F-A-1020 SA727 52Insulated Tubing and Pipe up to 4� FSD 1/2� Type A 4�, min. 4 pcf 1/4� 5/8� 3 1 F-A-5014 SA727 53Tubing and Pipe up to 4� WF 1/2� Type IA Foam Backer(3) 0� 7/8� 1 1/4 F-C-1069 SA727 54Insulated Tubing and Pipe up to 4� WF 1/2� Type IA Foam Backer(3) 0� 7/8� 1 3/4-1 F-C-5042 SA727 55Tubing and Pipe up to 4� CW 1/2� Type IA Foam Backer 0� 1� 2 0 W-J-1091 SA727 56Pipe up to 6� GW 1� Type FC 2-1/2�, min. 4 pcf 1� 1-5/8� 2 0 W-L-1027 SA727 57Pipe up to 4� GW 1/2� Type FC 2-1/2�, min. 4 pcf 1/4� 1-5/8� 1 0 W-L-1039 SA727 58Tubing up to 4� GW 1� Type FC — 1/4� 1-5/8� 2 0 W-L-1063 SA727 59Tubing up to 4� GW 1� Type FC — 1/4� 1-1/4� 1 0 W-L-1087 SA727 60Insulated Tubing up to 4� GW 1/4� Type FC 2�, min. 4 pcf(1) 1/4� 1/2� 2 1 W-L-5043 SA727 61Insulated Pipe or Tubing up to 4� GW 1� Type FC 1�, min. 4 pcf(1) 1/2� 5/8� 2 3/4 W-L-5044 SA727 62Inulated Tubing and Pipe up to 4� GW 1� Type IA Foam Backer(3) 0� 3/8� 2 1/2 W-L-5114 SA727 63Insulated Tubing and Pipe up to 3� GW 1/2� Type IA Foam Backer(3) 1/4� 1-1/8� 1-2 1/2-1 W-L-5115 SA727 64Cables Cables CW, CF 1� Type FC 3�, min. 4 pcf 1/4� 4� 3 0 C-AJ-3045 SA727 65Cables CW, CF 1/2� Type IA 4�, min. 4 pcf Varies Varies 2 0-1/2-1 C-AJ-3174 SA727 66Cables CW, CF 1/2� Type IA 4�, min. 4 pcf 3/4� 3-3/16� 2 1/2 C-AJ-3175 SA727 67Cables WF 1/2� Type IA Foam Backer(3) Varies Varies 1 3/4 F-C-3054 SA727 68Cables GW 1� Type FC 3�, min. 4 pcf 1/4� 4-1/2� 2 0 W-L-3023 SA727 69Cables GW 1/2� Type FC 3-7/8�, min. 4 pcf 1/2� 3-7/8� 1 0-1 W-L-3034 SA727 70Cables GW 1/2� Type IA Foam Backer(3) 1/2� 1-1/2� 1-2 1/4-1/2 W-L-3162 SA727 71Cables GW 1/2� Type IA Foam Backer(3) 1/4� 1� 1-2 1/4-1/2 W-L-3163 SA727 72Air Ducts Steel Duct, Nom. 18� x 6� CW, CF 1� Type IA 1�, min. 4 pcf Varies 1� 3 0 C-AJ-7062 SA727 73Steel Duct, Nom. 4� CW, CF 1/2� Type IA 4�, min. 4 pcf 1/2� 1-3/8� 2 0 C-AJ-7063 SA727 74Steel Duct, 24-ga., up to 3� x 10� GW 1/2� Type FC 2-1/2�, min. 4 pcf 7/16� 1-5/8� 1 0 W-L-7001 SA727 75Steel Duct, 28-ga. Galv., GW 1� Type FC 2-1/2�, min. 4 pcf 1/2� 1-5/8� 2 1/2 W-L-7002 SA727 76

Nom. 4� x 6�

4�, 26-ga., Galv. Steel Vent Duct GW 1/2� Type IA Foam Backer(3) 0� 1� 1-2 0 W-L-7057 SA727 77Glass PipeGlass Pipe, Nom. 3� GW 1/2� Type IA Foam Backer(3) 1/2� 1-1/8� 1 0 W-L-2227 SA727 78Plastic 1-1/2� or 2� Sched. 40 PVC Pipe CW, CF 1/2� Type IA Foam Backer 3/8� 3/4� 2 1-1/2 C-AJ-2295 SA727 79or SDR17 CPVC Pipe 1� Type 1A Foam Backer 1/4� 3/8� 2 1-1/2

3/4� PEX Tube or 1� ENT CW, CF 1/2� Type IA Foam Backer(3) 1/4� 7/16� 2 1-1/2- C-AJ-2296 SA727 801-3/4

1-1/2�, 2�, 3� or 4� CW, CF Wrap, Type A — Varies Varies 2 1 C-AJ-2301 SA727 81Sched. 40 PVC Pipe or Type IA(3)

4� Sched. 40 PVC or ABS Pipe CW, CF Wrap, Type A — 1/4� Varies 2 2 C-AJ-2304 SA727 82or Type IA(3)

1� Sched. 40 PVC Pipe FSD 1� Type IA Foam Backer 1/4� 7/16� 3 1-1/2 F-A-2062 SA727 834� Sched. 40 PVC Pipe or CW, CF 1/2� Type IA Foam Backer(3) 0� 1-1/2� 1 1 F-A-2063 SA727 84

4� SDR17 CPVC Pipe or 4� Sched. 40 PVC Conduit

6� Sched. 40 PVC or CF Wrap, — Varies Varies 2-3 1-1/2- F-A-2064 SA727 856� SDR135 CPVC Pipe Type A or 2-1/2

Type IA(3)

Codes for Type of Floor, Roof orWall: CF-Concrete Floor, CW-Concrete Wall, FSD-Fluted SteelDeck, GW-Gypsum Wall, WF-Wood Floor.

Codes for Firestopping Material:Type A-FIRECODE Acrylic FirestopSealant (regular ); Type A-SP-FIRECODE Acrylic Firestop SpraySealant (Type SA); Type AS—SHEETROCK® Brand AcousticalSealant; Type IA-FIRECODE IAIntumescent Acrylic FirestopSealant; Type FC-FIRECODECompound; Type SS-THERMAFIBER SMOKE SEALCompound; Wrap-TREMSTOPD Intumescent Wrap Strips.

(1) Pipe covering material. (2) Minimum depth dependent

upon annular spacedimensions.

(3) Optional. (4) Ceramic fiber. (5) 2-hr. wall. (6) 2-hr. (two layers 7/8�

backer rod); 1-hr. (bondbreaker tape).

(7) Two layers 7/8� backer rod.

BFThrough-Penetration Firestops

Page 40: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Type ofFloor, Firestopping Min. Max.

Penetrating Roof or Material Forming Annular Annular F T UL System FolderItem and Diameter Wall (Min. Depth) Material Space Space Rating Rating Number reference

Plastic (continued)3� Sched. 40 PVC or ABS Pipe WF Wrap, Foam Backer(3) 0� 1/2� 1 3/4 F-C-2179 SA727 86

1/2� Type IA

1-1/2� Sched. 40 PVC WF 1/2� Type IA Foam Backer(3) 0� 1� 1 1 F-C-2180 SA727 87or ABS Pipe

1-1/2� Sched. 40 PVC WF 1/2� Type IA Foam Backer(3) 0� 1� 1 1 F-C-2181 SA727 88or ABS Pipe

3� Sched. 40 PVC Pipe or WF 1/2� Type IA Foam Backer(3) 0� 1/2� 1 1 F-C-2182 SA727 893� SDR17 CPVC Pipe or 3� Sched. 40 PVC Conduit

4� Sched. 40 PVC or Sched. WF 1/2� Type IA Foam Backer(3) 0� 1/2� 1 3/4 F-C-2183 SA727 9040 ABS or SDR17 CPVC Pipe

2� SDR13.5 CPVC Pipe CW 1/2� Type IA Foam Backer 1/4� 1-3/8� 2 0 W-J-2068 SA727 912�, 3� or 4� Sched. 40 PVC Pipe GW Wrap, Type A — Varies Varies 2 1 W-L-2220 SA727 92

or Type IA(3)

Up to 4� Sched. 40 PVC or GW Wrap, — Varies Varies 1 0-1 W-L-2221 SA727 931-1/4� SDR135 CPVC Pipe Type A or

Type IA(3)

6� Sched. 40 PVC Pipe GW Wrap, — 0� 3/8� 2 1-1/2 W-L-2222 SA727 941/4� Type A or Type IA

2� SDR13.5 CPVC Pipe GW 1/2� Type IA Foam Backer(5) 1/4� 1-3/8� 1-2 1-2 W-L-2223 SA727 953/4� PEX Tube or 1� EMT GW 1/2� Type IA Foam Backer(3) 1/4� 3/8� 1-2 3/4-1- W-L-2224 SA727 96

1-1/2-1-3/4

1-1/2� Sched. 40 PVC Pipe GW 1� Type IA Foam Backer(3) 1/4� 5/8� 2 2 W-L-2225 SA727 972� Sched. 40 PVC Pipe GW 1/2� Type IA Foam Backer(3) 0� 7/8� 1 0 W-L-2226 SA727 988� Blank (no penetrant) 4-1/2� Concrete Floor, CW, CF 1� Type FC 3�, min. 4 pcf — 8� 3 0-1 C-AJ-0032 SA727 99

5� Concrete Wall

Type ofFloor, Firestopping Move-

Construction Roof or Material Forming Joint ment Comp./ Assembly UL System FolderJoint Systems Wall (Min. Depth) Material Width Class Exten. Rating Number reference

Floor Joint CF 1/2� Type A 4�, min. 2.5 pcf max. 2� — — 2 F-F-S-0028 SA727 100Head-of-Wall or Roof FSD, CF 1/2� Type FC 1-1/2�, min. 4 pcf max. 5/8� II & III 80%/ 1 HW-D-0001 SA727 101

Assembly (Slip Track) GW 60%

Head-of-Wall or Roof FSD, CF 2-1/2� Type FC — max. 5/8� II & III 80%/ 2 HW-D-0002 SA727 102Assembly (Slip Track) GW 60%

Head-of-Wall or Roof CW, CF 1� Type FC min. 4 pcf max. 1� II & III 25%/ 2 HW-D-0009 SA727 103Assembly (Slip Track) 12%

Head-of-Wall, Flat CF, GW 1/2� Type A (6) nom. 1� II & III 25% 1-2 HW-D-0158 SA727 104Head-of-Wall, Flat CW, CF 1/2� Type A (7) nom. 1� II & III 25% 2 HW-D-0159 SA727 105Head-of-Wall FSD, GW 1/8� Type A-SP min. 4 pcf nom. 1� II & III 25%/ 1-2 HW-D-0160 SA727 106Perpendicular/Parallel 25%

Head-of-Wall FSD, CW 1/8” Type A-SP min. 4 pcf nom. 1” II & III 25%/ 2 HW-D-0161 SA727 107Perpendicular/Parallel 25%

Head-of-Wall or Roof FSD, CF 1/2� Type FC 3-1/2�, min. 4 pcf max. 1/2� — — 1 HW-S-0001 SA727 108Assembly GW

Head-of-Wall or Roof FSD, CF 1� Type FC 3-1/2�, min. 4 pcf max. 1/2� — — 2 HW-S-0001 SA727 109Assembly GW

Wall Joint CF 1/2� Type AS — max. 1/2� — — 1 HW-S-0032 SA727 110Wall Joint CF 1� Type AS — max. 1/2� — — 2 HW-S-0032 SA727 111Wall Joint CF 1/2� Type AS min. 4 pcf max. 1/2� — — 1 HW-S-0035 SA727 112Wall Joint CF 1� Type AS min. 4 pcf max. 1/2� — — 2 HW-S-0035 SA727 113Wall Joint CW 1/2� Type A 4�, min. 2.5 pcf max. 2� — — 3 HW-S-0036 SA727 114

40

Through-Penetration FirestopsBF

Codes for Type of Floor, Roof orWall: CF-Concrete Floor, CW-Concrete Wall, FSD-Fluted SteelDeck, GW-Gypsum Wall, WF-Wood Floor.

Codes for Firestopping Material:Type A-FIRECODE Acrylic FirestopSealant (regular ); Type A-SP-FIRECODE Acrylic Firestop SpraySealant (Type SA); Type AS—SHEETROCK® Brand AcousticalSealant; Type IA-FIRECODE IAIntumescent Acrylic FirestopSealant; Type FC-FIRECODECompound; Type SS-THERMAFIBER SMOKE SEALCompound; Wrap-TREMSTOP DIntumescent Wrap Strips.

(1) Pipe covering material. (2) Minimum depth dependent

upon annular spacedimensions.

(3) Optional. (4) Ceramic fiber. (5) 2-hr. wall. (6) 2-hr. (two layers 7/8�

backer rod); 1-hr. (bondbreaker tape).

(7) Two layers 7/8� backer rod.

Page 41: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 41

The federal government segment of the construction industry is in the midstof changing to metric measurement and the change may impact on U.S.Gypsum Company and USG Interiors, Inc., products.

What Is Changing?In metric construction, many of the building materials, systems anddocuments are affected. Dimensions—Units have changed from feet and inches to millimeters,scales from inch fractions to feet (for example, 1/4�=1�0�) to true ratios(such as 1:20). Drawings are not to be dual dimensioned, in order to avoiddimensional conflicts and errors.Specifications—Specs call for metric linear dimensions, areas andvolumes.Construction Products—A majority of construction products do notchange in size since they are not modular or panelized. They are simply“soft converted” or re-labeled in metric dimensions.Framing—Stud spacing has changed from 16� to 400 mm and 24� to 600mm. Wood studs keep their nominal name, or may be relabeled a nominal50 mm x 100 mm or a more exact size.Batt Insulation—Width has changed from 16� and 24� nominal to 400mm and 600 mm nominal.Ceiling Systems—Grids and lay-in ceiling tile, air diffusers and lightingfixtures, from 2�x2� to 600 mm x 600 mm and from 2�x4� to 600 mm x1200 mm. Grid profiles, tile thicknesses, air diffuser capacities andfluorescent tubes have not changed.

USG Corporation Metric PolicyUSG Corporation supports the intent of the metric conversion program. USGhas manufactured metric sized products for export for many years on aspecial order basis. USG will make every reasonable effort to make metricproducts available to the federal market on a special order basis.

USG Interiors, Inc., is prepared to offer metric sizes in most of itsacoustical panel and suspension systems.

From U. S. Gypsum Company, metric width and length SHEETROCK BrandGypsum Panel products will be available from designated manufacturingplants throughout the United States. Metric length DUROCK Brand CementBoard products will also be available from designated manufacturing plants.Certain minimum order quantities and up-charges may apply, as determinedby local market conditions.

Bag and pail products, including SHEETROCK Brand Joint TreatmentProducts, spray textures, gypsum plasters and other products carry softmetric designations for size and/or weight.

Important: The basic USG product line remains unchanged—standardfoot/inch/pound products previously available from USG will still be readilyavailable. The addition of metric length/width products will allow us to supplyall job requirements, whether standard or metric.

USG Corporation will offer assistance to construction professionals withregard to design, specification and installation issues involving our metricproducts, just as we always have with our standard products.

Metric EquivalentsDimension Conversion Type(1) Ft./In. mm(2)

SHEETROCK Gypsum PanelsThickness Soft 1/4� 6.4

3/8� 9.5

1/2� 12.7

5/8� 15.9

3/4� 19.1

1� 25.4

Width Hard 24� 600

48� 1200

Length Hard 8� 2400

10� 3000

12� 3600

Steel Stud FramingThickness (gauge) Soft .0179 (25) .45

.0270 (22) .69

.0329 (20) .84

Width Soft 1-5/8� 41.3

2-1/2� 63.5

3-1/2� 88.9

3-5/8� 92.1

4� 101.6

Length Hard 8� 2400

10� 3000

12� 3600

THERMAFIBER InsulationThickness Soft 1� 25.4

1-1/2� 38.1

2� 50.8

2-1/2� 63.5

3� 76.2

3-1/2� 88.9

4� 101.6

5-1/4� 133.3

6� 152.4

Width Hard 16� 400

24� 600

Length Hard 48� 1200(1) Conversion Type: “Soft” is metric relabeling with no physical change of dimension; “hard” is a physical changeto the metric dimension shown.(2) Conversion factors: Inches x 25.4 = mm; Feet x 304.8 = mm.

Notes: Availability: Items above are not stocked in metric lengths or widths. Minimum quantity orders may berequired. Leadtime should be determined; upcharges may apply. Geographic availability may vary and should beverified for the project location.Lengths: Shown on SHEETROCK Brand Gypsum Panels and steel stud framing for illustration purposes only.Framing Spacing: 16� o.c. converts to 400 mm o.c.; 24� converts to 600 mm o.c.

For Information and AssistanceCheck current printed USG literature for more information on product sizingand availability. Information on specific metric product availability in yourmarket area may be obtained from USG sales or customer servicerepresentatives. They can be reached at local sales offices or order centers.To reach your nearest USG sales office, call toll-free:United States Gypsum Company—877 874-6655USG Interiors, Inc.—877 874-4200

Metric Conversions G

Page 42: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

42

Product/System StandardsI

Title Folder reference

Exterior Substrate Systems SA700Includes complete range of products for USG EXTERIOR™ Substrate Systems.USG Fire Stop Systems SA727Systems combine FIRECODE Compound and THERMAFIBER Safing Insulation toprovide wall and floor through-penetration firestops that combineexceptional economy and performance.Plaster Systems SA920Veneer basecoat and finish plasters; conventional basecoat, finish coat, andgauging plasters; accessories.Drywall/Steel Framed Systems SA923Fire-resistant interior and exterior steel framed drywall systems; partitions,chase walls, resilient partitions, curved drywall partitions, soffits, floors,ceilings, column and beam fireproofing.Drywall/Wood Framed Systems SA924Basic gypsum drywall assemblies offer economical, quickly erected, load-bearing partitions, walls and ceilings wherever fire protection is desired withwood framing.USG Area Separation Fire Wall/Party Wall Systems SA925Lightweight, non-load-bearing gypsum drywall assemblies designed asvertical fire barriers for fire walls and party walls in wood-frame apartmentsand townhouses.

Title Folder reference

USG Cavity Shaft Wall Systems SA926Fire-resistant drywall partitions for enclosing shafts in multi-story buildings;engineered design provides a thin, lightweight assembly that offers fasterinstallation and lower material costs.Gypsum Panels & Accessories SA927Gypsum panels, coreboard, sheathing; metal and plastic trim, brackets,control joints; screws and adhesives; joint treatments.SHEETROCK Brand Vinyl-Faced Gypsum Panels SA928Predecorated vinyl-faced gypsum panels; mouldings and accessories.Abuse-Resistant Systems SA929Abuse-resistant systems using gypsum panels, gypsum fiber panels andplaster products; also types of abuse and testing methods.DUROCK Brand Cement Board Systems SA932Ceramic tile backer board for interior walls, ceilings, floors, counter tops;adhesives, mortars, grouts.SHEETROCK Brand Textures and Finish Products SA933Ready-mixed and powder texture finishes; spray acoustical finish.STRUCTOCORE Security Wall Systems SA1119Steel forming for security walls, prison cells, high-abuse walls; steel meshdesign properties; details and specifications

Product/System CatalogsH

The listings below contain existing ASTM Standard Specifications whichapply to USG Corporation materials. Upon request United States GypsumCompany will provide product certification that these products comply withthe applicable ASTM standards and meet the performance values identifiedtherein.

ASTMProduct designationPlasterRED TOP gypsum plaster C28

RED TOP two-purpose plaster C28

RED TOP wood fiber plaster C28

STRUCTO-LITE plaster C28

RED TOP gauging plaster C28

RED TOP keenes cement regular quick trowel C61

STRUCTO-GAUGE plaster C28

STRUCTO-BASE plaster C28

IMPERIAL plaster C587

DIAMOND plaster C587

ASTMProduct designationGypsum lathingROCKLATH plaster base 3/8� & 1/2� C37

IMPERIAL gypsum base 1/2� & 5/8� C588

LimeRED TOP and GRANDPRIZE finish limes C206 type N

IVORY finish lime C206 type S

Gypsum panelsSHEETROCK Brand C36 (plain) (foil-back)

SHEETROCK Brand sq. edge C36

SHEETROCK Brand tap. edge C36

SHEETROCK Brand bev. edge C36

5/8� SHEETROCK Brand FIRECODE Core C36

SHEETROCK Brand FIRECODE C Core C36

SHEETROCK vinyl-covered C960

SHEETROCK Brand water-resistant C630

SHEETROCK Brand gypsum coreboard panels C442

SHEETROCK Brand shaft wall liner panels C442

Page 43: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

SA100/USG Corporation 43

Product/System Standards I

ASTMProduct designationSHEETROCK Brand exterior gypsum ceiling board C931

SHEETROCK Brand interior gypsum ceiling board C1395

FIBEROCK Brand panels—abuse-resistant C1278

FIBEROCK Brand panels—VHI abuse-resistant C1278

Cement panelsDUROCK Brand cement board C1325 (ANSI A 118.9)

DUROCK Brand exterior cement board C1186 (ANSI A118.9)

SheathingSHEETROCK Brand gypsum sheathing C79

Joint treatmentSHEETROCK Brand joint compounds C475

AccessoriesStructural steel joists, runners C645, C955, A568

A653,A792 (alum.-zinc coating),A591 (galv. coating)

25, 22 ga. studs, C645, A568 (steel),25, 22 ga. runners A653,

A463 (alum. coating),A792 (alum.-zinc coating)A591 (galv. coating)

20 ga. studs, 20 ga. runners C645, A568 (steel), A653 (galv. coating),A792 (alum.-zinc coating),A591 (galv. coating)

RC-1 resilient channels A568 (steel),A525 (galv. coating),A792 (alum.-zinc coating)

DUR-A-BEAD corner bead C1047

SHEETROCK Brand metal trims C1047

Shaft wall/area separation wall studs A653A792 (alum.-zinc coating)A591 (galv. coating)

Drywall screws C1002, C954

SHEETROCK Brand acoustical sealant C834

Acoustical units—prefabricatedACOUSTONE C423, C523, C635, C636, AURATONE C117, E84, E119, E1264

Ceiling suspension systemDONN Grid C635, C636, C645,

C841, E119, E1264

Mineral fiber insulationTHERMAFIBER sound atten. fire blanket C665

UL Designations/Products

UL Type Designation Drywall, Cement Board and Plaster Base ProductsR SHEETROCK Brand Gypsum Panels SCX SHEETROCK Brand Gypsum Panels, FIRECODE Core C SHEETROCK Brand Gypsum Panels, FIRECODE C Core WRX SHEETROCK Brand Gypsum Panels, FIRECODE Core, Water-Resistant WRC SHEETROCK Brand Gypsum Panels, FIRECODE C Core, Water-Resistant AR SHEETROCK Brand Abuse-Resistant Gypsum PanelsSLX SHEETROCK Brand Gypsum Liner Panels ULTRACODE SHEETROCK Brand Gypsum Panels, ULTRACODE Core SHX SHEETROCK Brand Gypsum Sheathing, FIRECODE Core FCV SHEETROCK Brand Gypsum Panels, FIRECODE Core, Vinyl-Covered FB SHEETROCK Brand Formboard FRX FIBEROCK Brand Panels—Abuse-Resistant and VHI Abuse-ResistantFRX-G FIBEROCK Brand Sheathing and FIBEROCK Brand Panels—Water-ResistantIPR IMPERIAL Brand Plaster Base IP-X1 IMPERIAL Brand Plaster Base (Type X) IP-X2 IMPERIAL Brand Plaster Base (Type C) IP-X3 IMPERIAL Brand Plaster Base, ULTRACODE Core DUROCK DUROCK Brand Cement Board DUROCK Exterior DUROCK Brand Exterior Cement Board UC ULTRAWALL Panel (Type C)

UL Type Designation Acoustical Tile and Panel Products

AP SANDRIFT™, FROST™, GLACIER™, "F" FISSURED™ Ceiling Panels AP-1 SANDRIFT™, FROST™, GLACIER™, "F" FISSURED™ Ceiling Panels FC-CB SHEETROCK® Brand Lay-In Ceiling Tile CLIMAPLUS ™

FR-83 Fissured, RADAR™, RADAR™ Illusion, RADAR™ CLIMAPLUS ™,RADAR™ CLIMAPLUS ™ Illusion, Aspen, Pebbled, Touchstone CLIMAPLUS™

Ceiling PanelsFR-81 ROCK FACE® CLIMAPLUS ™, CLEAN ROOM™ CLIMAPLUS™ Ceiling Panels FR-4 RADAR™ Ceramic CLIMAPLUS ™ Ceiling PanelsFR-X1 ECLIPSE™ CLIMAPLUS ™, MILLENNIA® CLIMAPLUS ™ Ceiling PanelsM METAL FACE CLIMAPLUS ™ Ceiling Panels

UL Type Designation Acoustical Suspension Products

CM CELEBRATION™ Metal Ceiling Panels (bare metal)CP CELEBRATION™ Metal Ceiling Panels (painted)DXL DONN® Brand DX® Suspension System (15/16� wide) DXL DONN® Brand DXL™ Concealed Suspension System (15/16� wide) DXLA DONN® Brand DX® Suspension System (15/16� wide, aluminum cap) DXLZ DONN® Brand DX® Suspension System (15/16� wide, galvanized body) DXLZA DONN® Brand DX® Suspension System (15/16� wide, galvanized body,

aluminum cap) ZXLA DONN® Brand DLXA™ Suspension System (15/16� wide, environmental) DXLT CENTRICITEE™ Suspension System (9/16� wide) DXLTA CENTRICITEE™ Suspension System (9/16� wide aluminum cap) DXLTZ CENTRICITEE™ Suspension System (9/16� wide, galvanized body) DXLTZA CENTRICITEE™ Suspension System (9/16� wide, galvanized body,

aluminum cap) DXLF FINELINE® Suspension System (9/16� wide) SDXL SIMPLICITEE™ Suspension System (15/16� wide, retail) SDXLA SIMPLICITEE™ Suspension System (15/16� wide, retail, aluminum cap) DGL USG Drywall Suspension System (15/16� wide) DGLW USG Drywall Suspension System (1-1/2� wide) DXLP PARALINE® Linear Metal Ceiling System PAR, PARP PARALINE® Linear Metal Ceiling System (components) PAS, PASP PARALINE® Linear Metal Ceiling System (components) PSR, PSRP PARALINE® Linear Metal Ceiling System (components) PSS, PSSP PARALINE® Linear Metal Ceiling System (components)

List of Code Research ReportsICBO ES

Report No. ER-1602 Regular and Resilient Gypsum Construction and Triple-Sealed Sheathing Report No. ER-1820 SHEETROCK Brand Gypsum Panels, Water-ResistantReport No. ER-5050 USG Fire Stop Penetration SystemsReport No. ER-5228 USG Exterior One-Coat Stucco SystemReport No. ER-5347 INSULSCREEN 2000 and 4000 EIF SystemsReport No. ER-5105 INSULSCREEN 2100 and 2600 EIF SystemsReport No. ER-5578 FIBEROCK Brand Sheathing and Water Resistant PanelsBOCA ESReport No. 89-13 USG Area Separation Fire Wall/Party WallReport No. 97-5 INSULSCREEN 2000 and 4000 EIF SystemsReport No. 97-1 INSULSCREEN 2100 and 2600 EIF SystemsReport No. 99-41 INSULSCREEN 2200 EIF SystemsReport No. 99-47 FIBEROCK Brand AR, VHI and XL Gypsum PanelsReport No. 99-54 FIBEROCK Brand Sheathing and Water Resistant Panels

SBCCI PST & ESIReport No. 9834 USG Area Seperation Fire Wall/Party WallReport No. 9753 INSULSCREEN 2000 and 4000 EIF SystemsReport No. 9610B INSULSCREEN 2100 and 2600 EIF SystemsReport No. 9818A FIBEROCK Brand AR, VHI and XL Gypsum Panels Report No. 9971 INSULSCREEN 2200 EIF SystemReport No. 2006 FIBEROCK Brand Sheathing, Water Resistant and Predecoraded Panels

National Evaluation Service*NER-258 USG Drywall Shaft Partition SystemsNER-259 DUROCK Brand Interior Cement Board SystemsNER-396 DUROSCREEN 1000 and 1100 Direct-Applied SystemsNER-458 SHEETROCK Brand Interior Gypsum Ceiling Board

* Recognized by ICBO, BOCA and SBCCI.

Page 44: USG SA100 Wall Construction Selector - tbci.cotbci.co/Downloads/USG-SA100-3-02-wall selector.pdf · How to Use This Selector This folder is divided into nine sections—A to I—covering

Manufactured by United States Gypsum Company125 South Franklin StreetChicago, IL 60606

© 2002, USG CorporationSA100/rev. 3-02Printed in U.S.A.

Technical Service

800 USG.4YOUWebsite

www.usg.comSamples/Literature

888 874.2450Samples/Literature E-mail

[email protected]/Literature/Fax

888 874.2348Customer Service

800 950.3839

of these goods not in accordancewith current printed instructions orfor other than the intended use.Our liability is expressly limited toreplacement of defective goods.Any claim shall be deemed waivedunless made in writing to us withinthirty (30) days from date it was or reasonably should have beendiscovered.Note All products described here may not be available in all geographicmarkets. Consult your local sales office or representative for information.Safety First!Follow good safety and industrialhygiene practices during handlingand installing of all products andsystems. Take necessary precau-tions and wear the appropriatepersonal protective equipment as needed. Read material safetydata sheets and related literature on products before specificationand/or installation.

TrademarksThe following trademarks usedherein are owned by USGCorporation or its subsidiaries:ACOUSTONE, AURATONE, CENTRICITEE,CERAMIC HERITAGE, CLEAN ROOM

CLIMAPLUS, DIAMOND, DONN, DUROCK,DUROSCREEN, ECLIPSE, FIBEROCK,FINELINE, FIRECODE, FROST, GLACIER,IMPERIAL, METAL FACE, MILLENNIA,ORION, PARALINE, RADAR, RC-1, RED

TOP, ROCK FACE, ROCKLATH, SANDRIFT,SHEETROCK, SIMPLICITEE, SMOKE SEAL,STRUCTOCORE, STRUCO-GAUGE,STURCTO-LITE, ULTRACODE, ULTRAWALL

and USG. TYPE S and TYPE S-12are trademarks of ITW Buildex.MASTERFORMAT is a trademark ofthe Construction SpecificationsInstitute. IVORY and GRAND PRIZE aretrademarks of GenLime Group L.P.TJI is a trademark of TrusJointMacMillan. WSI is a trademark ofWillamette Industries, Inc.THERMAFIBER is a trademark ofThermafiber LLC.NoticeWe shall not be liable for inciden-tal and consequential damages,directly or indirectly sustained, norfor any loss caused by application