users manual - kp · pdf fileusers manual. 2 ] order-clients p ecifications ... stamp supplier...

19
www.easy-conveyors.com USERS MANUAL

Upload: duongnhi

Post on 30-Mar-2018

216 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

www.easy-conveyors.com

USERSMANUAL

Page 2: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

2 ]

o r d e r - c l i e n t s p e c i f i c a t i o n sProject- ordercode

Date:

Ordercode:

Clientspecifications

Name company:

Projectcode:

Name client:

Street:

City:

State:

Zip code:

Country:

Telephone:

Fax:

E-mail:

Stamp supplier

Name supplier:

Name salesmanager:

Street:

City:

State:

Zip code:

Country:

Telephone:

Fax:

E-mail:

Easy Conveyors BV - www.easy-conveyors.com

Page 3: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 3

c o n t e n t s

f o r e w o r d

!

!

!

a) Foreword - Convention - Warnings - Liability - CE Standard

1] Introduction 1.1 Use 1.2 Product specification 1.3 Description of conveyor system 1.4 Technical specification of conveyor system 1.5 Noise level

2] Safety rules

3] Transport

4] Assembly/Installation4.1 Easy Conveyor components

4.2 Electrical components

5] Taking into use

6] Operating instructions 6.1 Operation 6.2 Maintenance

7] Maintenance 7.1 Introduction 7.1.1 Tools required 7.1.2. Chain 7.2 Safety rules for maintenance

7.3 Easy Conveyor components 7.3.1 Drive units 7.3.2 Transport chain 7.3.3 Cleaning 7.3.4 Slide strip 7.3.5 Side guides 7.4 Protection 7.5 Guarantee 7.6 Spares and replacement parts 7.7 Maintenance schedule

8] Maintenance of other components 8.1 Motors

9] Faults

10] Dismantling and disposal

11] Appendices A Manufacturerís declarations B Motors C Assembly drawings

ConventionIn this handbook, the Easy Conveyor system will be referred to as the conveyor.

WARNINGS ARE INDICATED IN THIS MANNER IN

THE HANDBOOK.

FOR THE INSTALLATION AND COMMISSIONING

OF EASY CONVEYORS, THE INSTRUCTIONS

IN SECTIONS 5 “COMMISSIONING” AND 7 “MAINTENANCE” MUST BE FOLLOWED.

This handbook is intended to be used by the ser-vice organization.

IT IS MOST STRONGLY ADVISED NOT TO USE THE

EASY CONVEYOR FOR ANY PURPOSE OTHER

THAN THAT SPECIFIED IN PARAGRAPH 1.1,“USE” ON PAGE 4.

LiabilityThis handbook is only applicable to the machine specified in Section 1.3, “Description of the con-veyor system” on page 4 and does not apply to equipment or to the interface with this equipment, other than as supplied by Easy Conveyor b.v.

CE Standard The conveyor is supplied in conformity with the CE Standard in accordance with Appendix IIB of the Machine Directive. 2006/42/EG

Easy Conveyors BV - www.easy-conveyors.com

Page 4: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

4 ]

1 - i n t r o d u c t i o n1.1 Use

The Easy Conveyor, machine no.: is intended to be used to transport the products described in paragraph 1.2 “Product specifica-

tion”. The machine can only be used after it has been installed as described in Section 4 “Assembly/installation” on page 5.

1.2 Product specification

Product description:

Dimensions ( L x W x H ):

Material:

Weight:

Quantity:

1.3 Description of the conveyor system

1.4 Technical specification of the conveyor system

Chain profile:

Chain:

Width of conveyor:

Slide rail:

Drive unit:

Conveyor speed:

Side guides:

Brackets for side guides:

Height of conveyor:

Support profile:

Support foot:

Chain material:

Profile materials:

Construction:

Environmental temperature:

For additional technical specifications, please refer to the section “Technical details” of Easy Conveyor Systems.

Easy Conveyors BV - www.easy-conveyors.com

Page 5: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 5

3 - t r a n s p o r t

2 - s a f e t y r u l e s

4 - a s s e m b l y / i n s t a l l a t i o n

5 - t a k i n g i n t o u s e

The conveyor must be handled with care to avoid damage or distortion.The conveyor can be simply separated into sections for the purposes of transportation and re-assembled again by making use of the coupling plates.

In order to prevent additional wear when both stainless steel and aluminium conveyors are re-assembled, make sure that the transition between the sections is smooth.

• When working on or close to the conveyor when it is in operation, ensure that you have no loosely-hanging clothing, neckties belts or other loose articles. The danger is that such items of clothing can become caught in return units,curves or drives units.

• Assembly, installation or maintenance activi-ties on the conveyor may only be carried out by qualified personnel.

• During the performance of maintenance activities, the maintenance switch for the drive unit concerned must be set to the 0 position (= off). When working activities are not being carried out in the immediate vicinity of the drive unit, it recommended that the switch be locked in the 0 position with a padlock (not supplied).

• (Wear hearing protectors while working in the immediate vicinity of an operational con-veyor system.)

1.5 Noise levelThe level of noise generated by the conveyor system when not transporting products is: dB.

If the working area(s) is (are) not or cannot be determined, the sound pressure measurement will be made at a position that is 1 m horizontally from the drive unit and 1.6 m vertically above the floor as specified in prEN 31200.

The measurements were made with a:

When new, the conveyor requires a running-in period of between 2 and 3 weeks. During this period, additional checks must be carried out. For this, refer to the maintenance schedule (Table 2) in Section 7.

4.1 Easy Conveyor components The conveyor is constructed, transported and delivered in modular form.

4.2 Electrical components The motor is delivered without cables and only needs to be connected to the control unit in accordance with the supplier’s instructions. The conveyor must always be started using a slow-start procedure - it must never be started at full speed.

Easy Conveyors BV - www.easy-conveyors.com

Page 6: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

6 ]

6 - o p e r a t i n g i n s t r u c t i o n6.1 Operation - When working on or close to the conveyor when it is in operation, ensure that that you have no loosely-hanging clothing, neckties belts or other loose articles. The danger is that such items of clothing can become caught in return units, curves or drive units.

- Assembly, installation or maintenance activities on the conveyor may only be carried out by qualified personnel.

6.2 Maintenance - Assembly, installation or maintenance activities on the conveyor may only be carried out by qualified personnel.

- Ensure that the conveyor cannot be started accidentally.

- Disconnect the power supply.

- Remove all products from the conveyor.

Easy Conveyors BV - www.easy-conveyors.com

Page 7: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 7

7 - m a i n t e n a n c e

!

!

!

!

!

7.1 Introduction

When they are properly maintained, Easy Con-veyor systems will have an almost trouble-free life. As with al mechanical equipment, some maintenance will be required. This section provi-des support for drawing up your own maintenance schedule.

MAINTENANCE ON EASY CONVEYOR SYSTEMS

MUST ONLY BE CARRIED OUT BY AUTHORIZED

PERSONNEL WHO ARE FAMILIAR WITH

THE EASY CONVEYOR MATERIAL.

IN CASE OF ANY DOUBT REGARDING THE MOST

SUITABLE MAINTENANCE PROCEDURE, IT IS RECOM-MENDED THAT CONTACT BE MADE WITH THE SUPPLIER.

7.1.1 Tools required For the maintenance of the Easy Conveyor

system, the following tools will be required: - ring/open-ended spanners, sizes 10, 13, 15 and 17 - set of hexagonal keys - screwdriver - chain tool

7.1.2 Chain The chains are manufactured from polyace-

tal, which combines the characteristics of good wear resistance, chemical stability,

good impact resistance and suitability over a wide range of temperatures.

AN ARROW IS MARKED ON THE UNDERSIDE OF THE

CHAIN LINKS - THIS MUST ALWAYS POINT IN THE

DIRECTION OF MOVEMENT.

The chain must not be pre-tensioned when it is being fitted. Pre-tensioning can result in increased wear of both the chain and the

slide strip. For this reason it is important that there is a visible loop in the chain close

to the drive unit when the conveyor is running.

The chain has a good impact resistance and breaking strength.

In order to function properly, each link in the chain must be secured correctly.

7.2 Safety rules for maintenance

- Remove all products from the conveyor.- It is always advisable to warn all personnel

in the vicinity of the conveyor that maintenance activities will be carried out. Whenever possi-ble, place warning notices on the conveyor and all associated operating equipment to reduce the risk of accidental starting.

- During the performance of maintenance activi-ties, always ensure that the power supply to the drive unit(s) concerned is switched off. Whenactivities will be performed in an area that is not in the immediate vicinity of the drive unit, it is necessary to make this absolutely clear.

- Ensure that all the equipment and replacement parts necessary to complete the maintenance activity are available.

7.3 Easy Conveyor components

7.3.1 Drive units• Slipping clutch (if present)

THE SLIPPING CLUTCH ON THE DRIVE UNIT IS

A SAFETY PROVISION FOR THE CONVEYOR BELT

AND THUS NOT FOR PERSONS.

• SafetyThe slipping clutch on the drive unit is a

protective device that stops the transport chain if it becomes overloaded. It has three purposes:

- the prevention of personal injury - the prevention of damage to the conveyor. - the prevention of damage to the products

• Precautionary measures 1. Stop the system 2. Remove all products from the conveyor 3. Ensure that the conveyor cannot be accidentally started 4. Disconnect the power supply

CAUTION: IF AN ATTEMPT IS MADE TO ADJUST THE

SLIPPING CLUTCH WHILE THERE ARE STILL PRODUCTS

ON THE CONVEYOR, THE TENSION PRESENT IN THE

TRANSPORT CHAIN CAN RESULT IN INJURY WHEN

THE SLIPPING CLUTCH IS RELEASED

Easy Conveyors BV - www.easy-conveyors.com

Page 8: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

8 ]

!

Before adjustments can be started, the tensile force for the transport chain must be calculated.

THE PLATES OF THE SLIPPING CLUTCH

MUST REMAIN DRY

• Checking the roller chainThe roller chain must be tensioned after 40, 200 and 600 operating hours and thereafter at intervals of 1,000 operating hours. It is also advisable during these

inspections to grease the chain with a suit- able lubricant. (See also Table 2, Maintenance schedule in paragraph 7.7).

• Checking the gearboxesIn general, visual inspection is sufficient.

Check for oil leakage around the gearbox and the sealing ring for the output shaft. Some motor gearboxes are supplied with pressure release plugs for the gearbox.

It is not possible for these to be fitted during transportation in connection with the

possibility of leakage. If pressure release plugs are delivered with the system these

must always be fitted to prevent premature collapse of the output shaft sealing ring. The

motor gearbox must also be inspected in accordance with the motor manufacturerís

instructions.

The gearbox for the drive unit is lubricated for life, so that in normal operating condi-

tions the lubricant need not be replaced. If circumstances require the oil in the gear- box to be renewed, select a type of oil from the following table. (Table 1)

• Check the bearings in the Easy Conveyor drive unit and the circulation unit

The bearings in the Easy Conveyor drive units and circulation units must be inspected at inter- vals of 1000 operating hours.

Inspection must be carried out as follows:

1. Remove the transport chain2. Rotate the drive shaft and/or the circulation

wheel manually and check to see if any play can be felt in the bearings. If play

is excessive, disassemble the drive unit or the circulation unit and replace the bearings.

3. Carry out a visual inspection of the plastic drive wheel and the circulation wheel.4. Re-fit all components and the chain.

• Drive unit chain guides In the drive unit, the transport chain is

guided by the flanges of the plastic side plates. These side plates also have guides

on the underside of the drive unit for the return section of the chain.

During each inspection of the drive units, these guides must also be visually inspected. If any damage to these guides is detected, they must be replaced immediately.

The failure of these guides can result in serious damage to the drive unit and the chain.

Type Temperatur ARAL BP ESSO MOBIL SHELL DEA in ºC

0 to +40 Degol G680 Energol Spartan Mobilgear Omala 680 Falcon GR-XP680 EP680 636 CLP680 -15 to +25 Degol BG220 Energol Spartan Mobilgear Omala 220 Falcon GR-XP220 EP200 630 CLP220 -20 to +10 Degol BG100 Energol Spartan D.T.E. 18 Omala 100 - GR-XP100 EP150 -45 to -20 - Energol Univis D.T.E. 11 Tellus T16 Aircraft LPT 22 J13 Hydr. Oil 15 Grease -15 to +40 Aralub Energrease Vibrax Mobilplex 44 Grease Orona FDP 00 HT-EP 00 EP370 S3655 FG EPO

Table 1 Types of lubricant

Easy Conveyors BV - www.easy-conveyors.com

Page 9: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 9

!7.3.2 Transport chain The tension in the transport chain must be checked after 40, 200 and 600 opera-

ting hours and thereafter at intervals of 1000 operating hours and must be tensioned if necessary. (See also table 2, Maintenance schedule in paragraph 7.7.) The chain is manufactured from an elastic

material. In addition to elastic stretching, material creep results in additional stretch

ing. The degree to which stretching occurs depends on the length of the chain and the tensile loading in the chain. This stretching is visible at the chain loop at the input side of the drive unit.

When the conveyor is operating, a small loop must be visible in the chain but when the conveyor is not running, there must be no loop visible.

TOO LARGE A LOOP IN THE CHAIN CAN RESULT

IN WEAR AT THE POINT WHERE IT ENTERS

THE DRIVE UNIT.

• Procedures for adjusting the length of the transport chain1. The length of the chain must be adjusted at the driving head of the conveyor.2. Ensure that the conveyor cannot be acci- dentally started.3. Disconnect the power supply4. Remove all products from the conveyor.5. If necessary, remove the black protective

cover from the transmission chain. Loosen the slipping clutch or remove the transmis- sion chain. The transport chain can now be moved manually.6. The transport chain must be tensioned in the conveyor by pulling the loop in the chain in

a downward direction. This loop will be found at the underside of the driving head.7. The chain can now be separated with the aid

of the chain pliers (Note: the stainless steel link pins can fall out). Now remove the surplus links and the re-join the ends of the chain. 8. Ensure that there is a good mechanical con-

nection to obtain an optimum conveyor movement.9. If necessary, re-fit the black protective cover over the transmission chain. The conveyor will now be ready to be restarted. Always start up the conveyor using a slow start.

7.3.3 Cleaning When the use of the conveyor has resulted in severe contamination, it is recommended

that the conveyor, including the drive unit and the return wheel including the motor be cleaned with warm water and a mild soap.

Easy Conveyors BV - www.easy-conveyors.com

Page 10: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

10 ]

!

Proceed as follows:1. Ensure that the conveyor cannot be started accidentally.2. Disconnect the power supply.3. If necessary, remove the black protective cover from the transmission chain and loosen the slipping clutch.4. Clean the conveyor and the transport chain.

NOTE:ONLY WARM WATER (MAX. 50ºC) MAY BE USED TO

CLEAN THE TRANSPORT CHAIN. A LIGHT SOAP SOLU-TION USING A MILD SOAP MAY BE USED TO REMOVE

STUBBORN CONTAMINATION FROM THE CHAIN.

5. Wait until everything is completely dry.6. Adjust the slipping clutch and re-fit the black protective cover over the drive unit.

The construction of the conveyor includes complete drainage.

7.3.4Slide strip

Coating the slide strip with silicone spray reduces the coefficient of friction and lengthens its life.

For stainless-steel conveyors, the stainless-steel profiles can be coated with a silicone spray (USDA-FDA approved). Shell Casida chainoil.

The slide strip must be visually inspected every 500 operating hours. The inspection must always be carried out on a stationary

conveyor with the chain in place The pur pose of the inspection is primarily to check

that the slide strip has not become sepa- rated from the fixing to the profile.

During the visual inspection, attention must be paid to the following points:1. Check the fixing on the profile2. Check the mutual joints3. Check that no cracks have occurred

At least once per year, or after 2,000 operating hours, the transport chain must

be removed from the chain profile so that the slide strip can be thoroughly inspected for wear and fixing (see also Table 2 Main- tenance schedule in paragraph 7.7.)

• Slide profile The slide profile is attached to the aluminium or stainless steel side profile by means of a snap fixing and, where necessary, by means of an additional plastic popnail.

7.3.5 Side guidesIn general, it should not be necessary to

include the side guides in a planned mainte-nance programme. However, during the inspection that is carried out after every 2,000 operating hours, it is advisable to

check for damage resulting from wear caused by scouring by the product or from

distortion caused by overloading of the side guides.

The side guide fixing pins can become loosened of the side guides are overloaded.

If they must be replaced, new pins must be used. Never employ used parts unless

this is absolutely necessary.

7.4 Safety provisions

Easy Conveyor components and systems are pro-vided with safety devices that are designed to pre-vent injury to personnel. They have been designed in accordance with the Machine Directive 2006/42/EG. Easy Conveyors may not be started up ifthese safety devices are not correctly fitted.

Protective covers may only be removed for main-tenance purposes and once maintenance activi-ties have been completed, they must be re-fitted.

If the system is dismantled, moved and re-installed by persons other than those who are familiar with Easy Conveyor products, then before the systemis again taken into use it must be checked for safety in accordance with Machine Directive 2006/42/EG.

Always check:1. That the protective cover for the drive unit transmission chain is correctly fitted2. That the chain loop is not visible under the side panels of the drive unit3. That the chain has the correct direction of movement

Easy Conveyors BV - www.easy-conveyors.com

Page 11: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 11

9 - f a u l t s

8 - m a i n t e n a n c e o fo t h e r c o m p o n e n t s8.1 MotorsIf you purchased the conveyor complete with motors, the connection and maintenance details will be found in Appendix B.

A broken link indicates that there is something wrong with the conveyor.

Common faults are broken links as a result of the chain becoming jammed at the transition between the conveyor and machines coupled with it. It is essential that broken links be replaced. Broken links can damage the slide strip and the drive unit entry guides.

Refer to the following table for an extensive symptom and fault description.

7.5 Guarantee

Easy Conveyors are guaranteed against manu-facturing and/or material faults for a period of six months from the date of delivery for a usage of eight operating hours per day.

In case of doubt, contact your supplier.

7.7 Maintenance schedule

7.6 Spares and replacement parts

Spare parts are available for most Easy Conveyors components. It is often less expensive to purchase fully assembled components.

However, for drive units an extensive range of components is available. Contact your supplier when you need components.

Components / hours 40 200 400 500 600 1.000 1.500 1.600 2.000 every

Drive unit Transmission chain 1000 hrs Bearings 1000 hrs

Transmission chain 1000 hrs

Side guides 2000 hrs

Slide strip Visual inspection 500 hrs Main inspection 2000 hrs

Table 3 Maintenance schedule

Easy Conveyors BV - www.easy-conveyors.com

Page 12: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

12 ]

SYMPTOM CAUSE CORRECTIVE MEASURE IF THE SYMPTOM PERSIST

Juddering movement Damaged or badly Check that the transport chain moves freely. mounted slide strip. Replace if necessary. Incorrectly adjusted Check and adjust the slipping clutch. slipping clutch. Worn drive components. Check/replace the transmission chain wheel. Transport chain tension Lengthen/shorten the transport chain. too high/too low. Dirty conveyor. Clean the transport chain/slide strip.

Drive unit runs but Slipping clutch incorrectly Check the adjustment of the slipping clutch. the drive chain does not adjusted. Slipping clutch plates Check and replace if necessary. worn or dirty. Damaged/incorrectly fitted Check that the transport chain can move freely. slide strip. Replace if necessary. Transmission components Check and fit if necessary. are not fitted.

Drive unit motor Conveyor is overloaded. Remove products from conveyor and test operation.overheating Check the current loading against the recommended loading. Gearbox leaking oil. Check the sealing ring for the output shaft and the packing Contact your supplier between the motor and the gearbox. Dirty conveyor Clean the transport chain.

Noisy Worn or damaged bearings Check/replace the drive unit/curve. in the drive unit or the curve. Damaged/badly mounted Check that the transport chain is free to move. slide strip. Replace if necessary. Transport speed Reduce the speed too high Compare the speed with the specifications. Transport chain tension Lengthen/shorten the transport chain. too high/too low

Abnormal wear on Conveyor overloaded. Remove products from conveyor and test the operation.the plastic components. Check that the transport chain can move freely. Check the current loading against the recommended loading. Environmental temperature Compare the environmental temperature too high with the specification Chemicals in the area attack Consult the VarioFlow S main catalogue the plastic components. for chemicals that may not be used. Damage caused by the Clean the conveyor system. ingress of contaminated particles loose dirt, etc Remove the source of contamination.

Table 4 Faults

Easy Conveyors BV - www.easy-conveyors.com

Page 13: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 13

1 1 - a p p e n d i c e s

1 0 - d i s m a n t l i n g a n dd i s p o s a l

1. In order to dismantle the Easy Conveyor system the following tools are required: - Open-ended spanners 10, 13, 15 en 17 - Set of hexagon keys - Hammer - Work gloves - Screwdriver - Chain tool 2. Switch off the conveyor. 3. Ensure that the power supply is completely disconnected. 4. Disconnect the power supply cable and remove the Maintenance switch. 5. Remove the bolts from the black drive unit protective cover and remove it. 6. Remove the transmission chain. 7. Loosen the slipping clutch. 8. Disconnect the chain. 9. Remove the transport chain.

10. Remove the side guides and the side guide brackets.11. Remove the slide strip.12. Unscrew the hexagon-head bolts from the drive unit coupling strips and remove the unit.13. Unscrew the hexagon-head bolts from the return wheel coupling strips and remove the unit.14. Loosen the hexagon-head bolts of the prolongation set of the curves.15. Remove the components from the supports. Make sure that the conveyor support cannot fall over.16. Remove the support.17. Sort the material for the purposes of disposal or re-use.18. If the drive unit will no longer be used, drain the oil out of the gearbox and collect it in a container intended for the purpose.

11.0 appendix

Appendix A Manufacturers declarationAppendix B MotorsAppendix C Assembly drawings

Easy Conveyors BV - www.easy-conveyors.com

Page 14: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

14 ]

a p p e n d i c e s AMANUFACTURER’S DECLARATION

(In accordance with Appendix II B of the Machine Directive, for non-independently functioning machines or machine parts)

Company:

Adress:

hereby declare that for the partly completed machinery identified as:Easy conveyor components( for the EBS, EMBS,EMCS, ETS & ERA system )

to which this declaration applies, is intended to be built into a machine or to be assembled with other machines to construct a single machine to which is applicable,

The product is in accordance with the following harmonized standard(s):

and satisfies the obligations arising from Appendix IV of the Machine Directive, for:

We wish to bring to your attention that our product is intended for

• in accordance with the Machine Directive• may only be taken into use after the complete (assembled) machine is in accordance with the provisions of the European requirements

City:

Country: Signature:

Date: Name:

NEN-EN 292-1 and 292-2

pr NEN-EN 1050

Easy Conveyors BV - www.easy-conveyors.com

EC Declaration of IncorporationIn accordance with the machine directive 2006/42/EG

Easy conveyors bv

Collse heide 54

5674 VN Nuenen

The Netherlands

hereby declare that for the partly completed machinery identified as :

Easy conveyor components

( for the EBS, EMBS, EMCS, ETS & ERA system )

- On page 2 from this declaration is mentioned which demands are being used and

fulfilled.

- the technical documentation is compiled in accordance with Annex VII(B) of the

Directive.

- We undertake to transmit, in response to a reasoned request by the appropriate

national authorities, relevant information on the partly completed machinery identified

above. The method of transmission shall be in a hard copy or digital format.

The machinery is incomplete and must not be put into service until the machinery into which it

is to be incorporated has been declared in conformity with the provisions of the Directive.

The Netherlands, Nuenen, 01-01-2012 Signed by General manager,

Page 15: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 15[ 15

Easy Conveyors BV - www.easy-conveyors.com

Essential safety and healthy demands concerning the development and design of themachinery in accordance with the machine directive 2006/42/EG

annex I done / filfulled annex I Done / filfulled annex I done / filfulledGeneral demands 1.5.11 yes / yes 3.6.1 n.a.1 yes / no 1.5.12 n.a. n.a. n.v.t.2 yes / yes 1.5.13 n.a. 3.6.3 ---3 yes / yes 1.5.14 n.a. 3.6.3.1 n.a.4 yes / yes 1.5.15 yes / yes 3.6.3.2 n.a.Essential safety and healthy lines 1.5.16 n.a. 4 n.a.1 --- 1.6 --- 4.1 ---1.1 --- 1.6.1 yes / no 4.1.1 n.a.1.1.1 Yes / n.a 1.6.2 yes / yes 4.1.2 ---1.1.2 yes / no 1.6.3 yes / no 4.1.2.1 n.a.1.1.3 yes / yes 1.6.4 yes / yes 4.1.2. n.a.1.1.4 yes / yes 1.6.5 yes / yes 4.1.2.3 n.a.1.1.5 yes / yes 1.7 yes / no 4.1.2.4 n.a.1.1.6 yes / yes 1.7.1.1 yes / yes 4.1.2.5 n.a.1.1.7 yes / no 1.7.1.2 yes / yes 4.1.2.6 n.a.1.1.8 n.a. 1.7.3 yes / no 4.1.2.7 n.a.1.2 --- 1.7.4. yes / no 4.1.2.8 ---1.2.1 yes / no 1.7.4.1 yes / no 4.1.2.8.1 n.a.1.2.2 yes / yes 1.7.4.2 yes / no 4.1.2.8.2 n.a.1.2.3 yes / yes 1.7.4.3 yes / yes 4.1.2.8.3 n.a.1.2.4 --- 2 n.a. 4.1.2.8.4 n.a.1.2.4.1 yes / yes 2.1 --- 4.1.2.8.5 n.a.1.2.4.2 yes / yes 2.1.1 n.a. 4.1.3 n.a.1.2.4.3 yes / yes 2.1.2 n.a. 4.2 ---1.2.4.4 yes / no 2.2 --- 4.2.1 n.a.1.2.5 yes / yes 2.2.1 n.a. 4.2.2 n.a.1.2.6 yes / yes 2.2.1.1 n.a. 4.2.3 n.a.1.3 --- 2.2.2 --- 4.3 ---1.3.1 yes / yes 2.2.2.1 n.a. 4.3.1 n.a.1.3.2 yes / yes 2.2.2.2 n.a. 4.3.2 n.a.1.3.3 yes / yes 2.3 n.a. 4.3.3 n.a.1.3.4 yes / yes 3 n.a. 4.4 ---1.3.5 yes / no 3.1 --- 4.4.1 n.a.1.3.6 yes / yes 3.1.1 n.a. 4.4.2 n.a.1.3.7 yes / no 3.2 --- 5 n.a.1.3.8 yes / no 3.2.1 n.a. 5.1 n.a.1.3.8.1 yes / no 3.2.2 n.a. 5.2 n.a.1.3.8.2 n.a. 3.2.3 n.a. 5.3 n.a.1.3.9 n.a. 3.3 n.a. 5.4 n.a.1.4 --- 3.3.1 n.a. 5.5 n.a.1.4.1 yes / no 3.3.2 n.a. 5.6 n.a.1.4.2 --- 3.3.3 n.a. 6 n.a.1.4.2.1 yes / no 3.3.4 n.a. 6.1 ---1.4.2.2 yes / no 3.3.5 n.a. 6.1.1 n.a.1.4.2.3 n.a. 3.4 --- 6.1.2 n.a.1.4.3 yes / no 3.4.1 n.a. 6.2 n.a.1.5 --- 3.4.2 n.a. 6.3 ---1.5.1 yes / yes 3.4.3 n.a. 6.3.1 n.a.1.5.2 yes / yes 3.4.4 n.a. 6.3.2 n.a.1.5.3 yes / yes 3.4.5 n.a. 6.3.3 n.a.1.5.4 yes / yes 3.4.6 n.a. 6.4 ---1.5.5 yes / yes 3.4.7 n.a. 6.4.1 n.a.1.5.6 yes / yes 3.5 --- 6.4.2 n.a.1.5.7 yes / yes 3.5.1 n.a. 6.4.3 n.a.1.5.8 yes / no 3.5.2 n.a. 6.5 n.a.1.5.9 yes / yes 3.5.3 n.a..5.10 yes / yes 3.6 ---

Page 16: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

16 ]

Easy Conveyors BV - www.easy-conveyors.com

[ 15

FDA APPROVEMENTS

Re: Regulatory Compliance Statement for Food Contact Articles We have statements from our raw material suppliers for UHMW PE material, which is used for our standard extrusion profiles, that the above mentioned materials comply with the USA Food and Drug Administration’s regulation 21 CFR, section 177.1520 and according to the regulation may be safely used as articles or components of articles intended for repeated food contact, in contact with all types of food. The same applies to the additives which are covered by section 178.2010.

Re: TCS & TCP sliding profiles

TCS & TCP has been used in USDA inspected food plants for over 20 years. TCS & TCP is a patented blend of UHMW and other ingredients, all of which are FDA approved for incidental food contact. TCS & TCP contains no silicones or other non-FDA approved materials

Easy conveyors bv

Eric Willems Managing director

Page 17: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

[ 15[ 17

Easy Conveyors BV - www.easy-conveyors.com

Declaration of food contact compliance

Easy conveyors bv certifies that the plastic chain material consisting in

Polyoxymethylene ( Acetal)

Material code 81579, used for the production of our plastic modular belts, is in compliance with the requirements of the following food contact regulations and their amendments:

- Unified European norm (EU) No 1282/2011 of 28 November 2011 amending and correcting Commission Regulation (EU) No 10/2011 of 17 January 2011 “ on plastic materials and articles intended to come into contact with food”

Restrictions: None

- FDA ( Food and Drug Administration )norm, Code of Federal Regulation 21CFR 170.39 “Threshold of regulation for substances used in food contact articles”

Restrictions: for use conditions type A ( high temperature heat sterilized over 212F ) according to Table 2 CFR 21, this material is compliant for direct contact only with food types: I Non acid, aqueous products; may contain salt or sugar or both(ph abobe 5.0) IV-B Dairy products and modifications: oil in water emulsions, high or low fat For other food types, under A use conditions, the above mentioned material is not compliant. Migration tests have been performed on the finisched article material Easy conveyors bv

Eric Willems Managing director

Page 18: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

18 ]

Easy Conveyors BV - www.easy-conveyors.com

[ 15

Page 19: USERS MANUAL - KP · PDF fileUSERS MANUAL. 2 ] order-clients p ecifications ... Stamp supplier Name supplier: Name salesmanager: ... 0 to +40 Degol G680 Energol Spartan Mobilgear Omala

Easy Conveyors BVThe Netherlands

Address:Collse Heide 54

5674 VN NuenenThe Netherlands

E-mail: [email protected]

Telephone:+3140-283.83.19

Fax:+3140-283.59.99

www.easy-conveyors.com