indoor use only ABC-19-U_R0_ 100kΩ 710kΩ V Domotica Box Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands 1 2 3 4 5 6 7 8 USB USB RS 232 RS 232 + - < 4V = 0 > 6V = 1 Play Select Pair Unpair User manual Domotica Box ABC-19 WARNING: Important safety instructions. Follow all instructions, since incorrect installation can lead to severe injury. Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. WARNING: 1. General information The ABC-19 is a control box for motorised Coulisse blinds. Up to 8 favourite positions can be set for each blind. When one of the eight scenario’s is played, the blinds moves to the corresponding position. The box can be used stand-alone or integrated into an existing automation system. ABC-19 Power supply 12-24VDC Number of scenario’s 8 Frequency 2.4Ghz Range (inside building) 20mtr, 2 concrete walls 1.1 Specifications 1.2 Buttons Voeding 1Hz 2.3 Programming safety settings on multiple scenario’s - An input with the highest number overrules a lower input number. - Situation: 2 safety scenario’s are activated. If the scenario with the highest priority is de-activated, the lower priority scenario will be in force. - If you have more than one Domotica Box, the input with highest number has priority. If scenario’s with same numbers are active, the one that is activated first, will be in force. 2.5 Play safety settings For security reasons a safety setting is active if the output is high. To deactivate a safety scenario, the output must be connected to the ground. If a blind does not receive commands from the Domotica Box, the blind deactivates after one hour. Disclaimer: © Copyright Coulisse All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, by any means, electronic, mechanical, photocopying, recording, digital or otherwise without the written permission of the publisher. Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due to mistakes and/or faults in this manual. Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without obligation to notify any person or entity of such revisions or changes. The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.nl or contact your Coulisse contact person. We invite you to send remarks and comments about this manual to Coulisse at [email protected]. 2. Programming 2.1 Pair/unpair a blind with a Domotica box scenario Set the blind (or blinds) in the desired position Set the blind (or blinds) in program mode* Select the desired scenario on the Domotica Box 1. Press the green button to pair (add) the scenario to the blind Exit program mode on the blind(s) 2. Press the red button to unpair (remove) the scenario from the blind 3. Press the red + green button at the same time to use the scenario as ‘stop’ command for the blinds* Set the Domotica Box in program mode: Press Play and Select at the same time Select the desired scenario* Press the blue button (Pair) to select the safety setting: Led lights green orange (Red = no safety setting). 2.2 Programming safety settings* A safety setting can be programmed for any scenario. In case of fire or maintenance the safety scenario is played. The blinds are secured and do not respond to other scenario’s. It is also possible to block the use of remote controls. * Only available on motors produced after august 2010. Safety option 1 (green): When the safety scenario is activated other scenario’s are ignored. Operating individual blinds with a remote control is still possible. Safety option 2 (orange): When the safety scenario is activated, other scenario’s are ignored. Operating individual blinds with a remote control is NOT possible. Exit Program mode by pressing Play and Select at the same time 2.4 Cancel safety settings Set the Domotica Box in program mode: Press Play and Select at the same time Press and hold the Select button. After 7 seconds the LEDs light up green. The safety settings are removed from the scenario’s. 6. Service & Support 5. Safety & Cleaning 5.1 Safety 5.2 Cleaning Follow these general rules when cleaning the outside of the device and its components: - Make sure the device is unplugged. - Use a damp, soft, lint-free cloth. Avoid getting moisture in openings. - Don’t use aerosol sprays, solvents, alcohol, or abrasives. Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. WARNING: Do not make repairs yourself. Do not attempt to open the device or disassemble it. You run the risk of electric shock and voiding the limited warranty. No user-serviceable parts are inside. WARNING: - Do not let children play with the blind and/or remote control. - Only use powersupplies or batteries that comply with the specifications on the motor. - In case of malfunction, unplug the device or remove the batteries and contact your dealer. - Take care that the blind can move freely and is not blocked by objects. - Take care that the powersupply cable is out of reach for children. - Do not paint the device. - Keep the device dry. Online Resources For the latest information and updated manuals go to www.coulisse.nl. Obtaining Warranty Service First follow the advice in this booklet and then go to your local dealer. If the product appears to be damaged or does not function properly, go to your local dealer for instructions on how to obtain warranty service. 4. Tips & Troubleshooting Please check www.coulisse.nl for the latest tips and troubleshooting guide. 3. Using the RSR232 interface 3. Playing scenario’s Scenario’s can be played in three ways, using the: - buttons on the Domotica Box - 8 analog inputs - RS232 interface Scenario’s can be played subsequently with 1,5 seconds in between. Directly play the same scenario again to stop the blinds. Blinds can also be stopped with the remote control. 1 Using the buttons on the Domotica Box Select the desired scenario* Press the blue Play button to play the scenario 2 Using the 8 analog inputs Connect the input with the ground to play the scenario. Safety scenario’s: a safety scenario is active if the input is disconnected from the ground. Settings: baudrate 9600, 8 bits, no parity, 1 stopbit, no handshake Protocol: The Domotica Box reacts only on incoming messages. It does not broadcast. Command ends with ‘line feed code’. ‘Line ends’ are also allowed. The Domotica Box reacts not on empty incoming messages. Commands are not case sensitive. Device commands: PLAY, INPUT and INFO PLAY S[scenario number] Plays the specific scenario. Scenario’s are S1 – S8 Example: Command: PLAY S5 Response: OK INFO Reads out the software version of the Domotica Box. INPUT I[input number] Reads out the voltage on the specific input. Inputs are numbered I1 – I8 Example: Command: INPUT I4 Response: I4=80V (8,0 Volt) GB0 Zenden-ontvangen Scenario indicator The power LED flashes on 2Hz. * This can be done in three ways: press the program button on the motor or by remote control ABC-01: Channel Select or Single Select. ** When the scenario is played the blind does not move to a position, but stops immediately. * Safety settings can be programmed for each scenario. * If a scenario is selected, the analog inputs are disabled. After 30 seconds the selection will be undone. Or press the Select button until none of the scenario’s is selected.

Upload: others

Post on 15-Oct-2019

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: User manual 2. Programming 2.3 Programming safety settings ... portal files... · 2.3 Programming safety settings on multiple scenario’s - An input with the highest number overrules

indoor use only

ABC-19

-U_R0_

100kΩ

710kΩ V

Domotica Box

Coulisse B.V., Vonderweg 48, 7468 DC Enter, The Netherlands

1 2 3 4 5 6 7 8

USB

USB

RS 2

32

RS 2

32

+

-

< 4V = 0

> 6V = 1

Play

Select

Pair

Unpair

User manualDomotica Box ABC-19

WARNING: Important safety instructions. Follow all instructions,

since incorrect installation can lead to severe injury.

Do not make repairs yourself. Do not attempt to open the device

or disassemble it. You run the risk of electric shock and voiding

the limited warranty. No user-serviceable parts are inside.

WARNING:

1. General informationThe ABC-19 is a control box for motorised Coulisse blinds. Up to 8 favourite positions can be set

for each blind. When one of the eight scenario’s is played, the blinds moves to the corresponding

position. The box can be used stand-alone or integrated into an existing automation system.

ABC-19

Power supply 12-24VDC

Number of scenario’s 8

Frequency 2.4Ghz

Range (inside building) 20mtr, 2 concrete walls

1.1 Specifi cations

1.2 Buttons

Voeding 1Hz

2.3 Programming safety settings on multiple scenario’s

- An input with the highest number overrules a lower input number.

- Situation: 2 safety scenario’s are activated.

If the scenario with the highest priority is de-activated, the lower priority scenario

will be in force.

- If you have more than one Domotica Box, the input with highest number has priority.

If scenario’s with same numbers are active, the one that is activated fi rst, will be in force.

2.5 Play safety settings

For security reasons a safety setting is active if the output is high.

To deactivate a safety scenario, the output must be connected to the ground.

If a blind does not receive commands from the Domotica Box, the blind deactivates

after one hour.

Disclaimer:

© Copyright Coulisse

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, by any means,

electronic, mechanical, photocopying, recording, digital or otherwise without the written permission of the publisher.

Although this manual has been composed with the most care, Coulisse B.V. does not accept any responsibility for damage due

to mistakes and/or faults in this manual.

Coulisse B.V. reserves the right to revise the manual and to revise and/or changes its content at any time, without obligation to notify

any person or entity of such revisions or changes.

The most recent version replaces older versions of this manual. The most recent version is available at ww.coulisse.nl or contact

your Coulisse contact person.

We invite you to send remarks and comments about this manual to Coulisse at [email protected].

2. Programming2.1 Pair/unpair a blind with a Domotica box scenario

Set the blind (or blinds) in the desired position

Set the blind (or blinds) in program mode*

Select the desired scenario on the Domotica Box

1. Press

the green button to pair (add)

the scenario

to the blind

Exit program mode on the blind(s)

2. Press

the red button

to unpair (remove)

the scenario from

the blind

3. Press the red + green button at the same time

to use the scenario

as ‘stop’ command

for the blinds*

Set the Domotica Box in program mode:

Press Play and Select at the same time

Select the desired scenario*

Press the blue button (Pair) to select the safety setting:Led lights green orange

(Red = no safety setting).

2.2 Programming safety settings*A safety setting can be programmed for any scenario. In case of fi re or maintenance

the safety scenario is played. The blinds are secured and do not respond to other scenario’s.

It is also possible to block the use of remote controls.

* Only available on motors produced after august 2010.

Safety option 1 (green): When the safety scenario is activated other scenario’s are ignored.

Operating individual blinds with a remote control is still possible.

Safety option 2 (orange): When the safety scenario is activated, other scenario’s are ignored.

Operating individual blinds with a remote control is NOT possible.

Exit Program mode by pressing Play and Select

at the same time

2.4 Cancel safety settings

Set the Domotica Box in program mode:

Press Play and Select at the same time

Press and hold the Select button. After 7 seconds the LEDs light up green.

The safety settings are removed from the scenario’s.

6. Service & Support

5. Safety & Cleaning5.1 Safety

5.2 Cleaning

Follow these general rules when cleaning the outside of the device and its components:

- Make sure the device is unplugged.

- Use a damp, soft, lint-free cloth. Avoid getting moisture in openings.

- Don’t use aerosol sprays, solvents, alcohol, or abrasives.

Do not make repairs yourself. Do not attempt to open the device

or disassemble it. You run the risk of electric shock and voiding

the limited warranty. No user-serviceable parts are inside.

WARNING:

Do not make repairs yourself. Do not attempt to open the device

or disassemble it. You run the risk of electric shock and voiding

the limited warranty. No user-serviceable parts are inside.

WARNING:

- Do not let children play with the blind and/or remote control.

- Only use powersupplies or batteries that comply with the specifi cations on the motor.

- In case of malfunction, unplug the device or remove the batteries and contact your dealer.

- Take care that the blind can move freely and is not blocked by objects.

- Take care that the powersupply cable is out of reach for children.

- Do not paint the device.

- Keep the device dry.

Online Resources

For the latest information and updated manuals go to www.coulisse.nl.

Obtaining Warranty Service

First follow the advice in this booklet and then go to your local dealer.

If the product appears to be damaged or does not function properly,

go to your local dealer for instructions on how to obtain warranty service.

4. Tips & TroubleshootingPlease check www.coulisse.nl for the latest tips and troubleshooting guide.

3. Using the RSR232 interface

3. Playing scenario’s

Scenario’s can be played in three ways, using the:

- buttons on the Domotica Box

- 8 analog inputs

- RS232 interface

Scenario’s can be played subsequently with 1,5 seconds in between.

Directly play the same scenario again to stop the blinds.

Blinds can also be stopped with the remote control.

1 Using the buttons on the Domotica Box

Select the desired scenario* Press the blue Play button

to play the scenario

2 Using the 8 analog inputs

Connect the input with the ground

to play the scenario.

Safety scenario’s: a safety scenario

is active if the input is disconnected

from the ground.

Settings: baudrate 9600, 8 bits, no parity, 1 stopbit, no handshake

Protocol:The Domotica Box reacts only on incoming messages. It does not broadcast.

Command ends with ‘line feed code’. ‘Line ends’ are also allowed.

The Domotica Box reacts not on empty incoming messages.

Commands are not case sensitive.

Device commands:PLAY, INPUT and INFO

PLAY S[scenario number]

Plays the specifi c scenario. Scenario’s are S1 – S8

Example:

Command: PLAY S5

Response: OK

INFO

Reads out the software version of the Domotica Box.

INPUT I[input number]

Reads out the voltage on the specifi c input. Inputs are numbered I1 – I8

Example:

Command: INPUT I4

Response: I4=80V (8,0 Volt)

GB0

Zenden-ontvangen

Scenario indicator

The power LED

fl ashes on 2Hz.

* This can be done in three ways: press the program button on the motor or by remote control ABC-01:

Channel Select or Single Select.

** When the scenario is played the blind does not move to a position, but stops immediately.

* Safety settings can be programmed for each scenario.

* If a scenario is selected, the analog inputs are disabled. After 30 seconds the selection will be undone.

Or press the Select button until none of the scenario’s is selected.